Wireless IP WIFI Digital Microscope User Manual 8+
Front Back Micro USB port Main body LED button
(Backlight control) USB / OFF / WiFi mode switch Zoom in / out Parts list Lens Stand x1 Adapter (for tripod) x1 Main body x1 USB cable x1 Prepared slide x1 Charger Turn o the device
(Wireless IP WiFi Digital Microscope) Low battery (red light) Charging (red light) Full battery Switch o Steady Blinking 1 How to connect with USB and WiFi WiFi MODE 1 Blue Light Flashing After switch to WiFi mode, the unit will be ready for connecting till Blue Light Flashing SSID: Camera-ESL-
xxxxxx Password: 88888888 SSID:
Camera-ESL-xxxxxx
(Series No) Password: 88888888 LED ON / OFF Capture xxxxxx 2 IP viewer Open a web browser and enter the address in the address bar, then hit Enter. Address:
http://192.168.100.1 To avoid interference with other hardware change the Camera name/ Password/ Channel , click save and reboot button. Please wait to reboot and try to follow these steps to reconnect. 1. Reboot Wi microscope to take eect 2. Connect to wireless network with SSID - New camera name/ New password 3. Browse http://192.168.100.1
* Recommended to connect a maximun 4 devices at the same time. 2 How to connect with USB and WIFI USB MODE 1 Green light in USB mode The green LED will ash during data transfer in USB mode
**SKYPE viewer 2 for Mac Open Skype Preferences Audio/video Camera-ESL for windows Open Skype Call Audio Settings Camera-ESL
**Download and Install SKYPE To download the SKYPE software, please visit SKYPE website for instructions of installation and how to use it. www.skype.com 3 Photo Booth viewer (Mac only) Open Photo Booth Camera Camera-ESL Camera-ESL 3 WiFi Microscope with stand and slide A Press for a second to turn Backlight on If you want to turn the Backlight B o, press A for a second again B A B Focus Main body 2 1 B A Slide A B 4 A B Slide WiFi Microscope with adapter (for tripod) 1 2 3
* Tripod not included Zoom In/Out 4 5 5 Firmware Upgrade Firmware Upgrade 1. Download & Extract compressed rmware xxxxxx-MS079"
from http://www.edu-science.com/downloads.php?type=software 2. Turn o the Wire (Wireless IP Wi Digital Microscope) 3. Connect the USB cable from the Wireless IP Wi Digital Microscope to the PC. 4. Press and Hold the "LED" button for 5 seconds while selecting the "wi" mode. 5. Upon successful installation, a new Hard Disk Drive will be shown as "System" & "Application"
6. Delete all les in the "System's" in the Hard Disk Drive 7. Copy and Paste the compressed "rmware xxxxxx-MS079" les to the "System"
8. Turn o the Wireless IP Wi Digital Microscope 6 General Specication Image sensor :
Main processor :
Image size :
Magnication:
Power source :
Battery life :
Charger :
USB port :
Wireless standards :
Wireless range :
Supported devices :
Software requirements :
Device Lifespan Operating conditions :
OmniVision, 1/5 inch, 2.0 MP, CMOS sensor 240Mhz ARM926 CPU 1280*720USB & 640*480WiFi Basic 8x (3.5 LCD) and variable for larger LCD screens Internal 1100mAh lithium-ion battery 2 hours 5V adapter or USB power source USB 2.0 (USB 1.1 compatible) IEEE 802.11nIEEE 802.11gIEE 802.11b 10m indoors, 30m outdoors Android & iOS phones, tablets, notebooks Web browser(WiFi), Skype(USB) 2 years Commercial grade 0 to +50C 20% to 95%
BATTERY INSIDE THE WIFI DIGITAL MICROSCOPE IS NOT REPLACEABLE. FCC NOTE: FCC ID:Q6NMS079 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS OR CHANGE TO THIS EQUIPMENT. SUCH MODIFICATIONS OR CHANGE COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. Rechargeable batteries are only to be charged by supervisory adult or children over 8 years. instructions, may cause harmful in accordance with the Hereby, Edu-Science (C.P.) Ltd. , declares that this Wireless IP WIFI Digital Microscope is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. P38-MS079-81001000 Wireless IP Wifi Digital Microscope Model No.: MS079 0070