all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
RolTop 1 | Users Manual | 1.90 MiB | September 08 2013 | |||
1 |
|
RolTop 2 | Users Manual | 1.51 MiB | September 08 2013 | |||
1 |
|
SunTop 1 | Users Manual | 1.88 MiB | September 08 2013 | |||
1 |
|
SunTop 2 | Users Manual | 1.54 MiB | September 08 2013 | |||
1 | Block Diagram | September 08 2013 | ||||||
1 | Cover Letter(s) | September 08 2013 | ||||||
1 | External Photos | September 08 2013 | ||||||
1 | Internal Photos | September 08 2013 | ||||||
1 | ID Label/Location Info | September 08 2013 | ||||||
1 | ID Label/Location Info | September 08 2013 | ||||||
1 | Attestation Statements | September 08 2013 | ||||||
1 | Test Setup Photos | September 08 2013 | ||||||
1 | Test Report | September 08 2013 |
1 | RolTop 1 | Users Manual | 1.90 MiB | September 08 2013 |
Roller shutter drive RolTop 120 V / 60 Hz Table of contents 5.7 Technical data 1 2 2.1 2.2 2.3 Operating and installation instructions General information Standards and guidelines Intended use Foreseeable misuse 2.4 Warranty and liability 2.5 Customer service of the manufacturer 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 5 5.1 5.2 5.3 5.4 5.5 5.6 Safety General safety instructions Layout of safety instructions General safety principles General obligations of the operator General requirements on personnel Safety instructions on technical condition Safety instructions on transport, assembly and installation Safety instructions on operation Safety instructions on electrical installation Product description Installation Mechanical mounting Electrical connection Connection example, RolTop 120 V / 60 Hz Parallel connection Commissioning End position and relief settings 5.6.1 Relief function for end position(s) 5.6.2 Relief function at the upper stop 5.6.3 Relief function at the lower stop 5.6.4 Changing / deleting of end positions and deleting the relief function 5.6.5 Four options for end position settings 5.6.6 Option A: Upper and lower end position freely con gurable 7 5.6.7 Option B: Fixed upper end position, lower end position freely con gurable 5.6.8 Option C:
Fixed upper and lower end position 5.6.9 Option D:
Upper end position freely con gurable, xed lower end position 1 1 1 2 2 2 2 2 2 2 3 3 3 3 4 4 4 4 4 5 5 6 6 6 6 6 6 6 6 6 7 7 8 6 7 8 9 10 11 12 13 14 Troubleshooting Servicing Cleaning Repair Address Disassembly and disposal EC Declaration of Conformity EN: Addendum to the manual UL approval FR: Addendum au manuel Homologation UL 8 8 8 8 8 8 8 9 9 9 Roller shutter drive RolTop 120 V / 60 Hz 1 Operating and installation instructions 2 Please keep these operating instructions for later use and have them available during the complete service life of the product!
The German version of these operating instructions is the original version. All foreign language documents are translations of the original version. All rights reserved with regard to patent claim or submission of design or utility patent. General information The structure of these operating instructions is based on the service life phases of the electrical drive (subsequently referred to as product). The manufacturer reserves the right to make changes to the technical data included in these operating instructions. The-
se may deviate from the respective model of the product while the factual information are generally not changed and are not losing their validity. The current state-of-the-art can be obtained from the manufacturer at all times. Potential claims cannot be asserted. Deviations from text and pictori-
al statements are not possible and depending on the tech-
nical development, setup and accessories of the product. Deviating information on special models are included by the manufacturer in the sales documentation. Other information shall remain unaffected by this. 2.1 Standards and guidelines During system design, basic safety and health requirements of applicable laws, standards and guidelines were obser-
ved. The safety is con rmed by means of the Declaration of Conformity (refer to EC Declaration of Conformity). All safety information in these operating instructions are based on currently applicable laws and regulations in Germany. All information in the operating instructions must be obser-
138186501_US+CA_0513 Intended use | Safety 2.2 ved at all times. Apart from the safety instructions in these operating instructions, applicable local regulations on pre-
vention of accidents, environmental protection and occupa-
tional safety must be observed. Regulations and standards for safety assessment can be found in the EC Declaration of Conformity. Intended use This product is intended for use in facade construction for driving electrical sun protection devices. Decisive for the determination of the drive system is the elero drive computation program (http://elero.com/
en;service;drive-computation-program.htm). Other applications must be approved in advance by the ma-
nufacturer elero GmbH Antriebstechnik (refer to Address). The operator alone is liable for all damage due to improper use of the product. The manufacturer does not assume any liability for personal injuries and property damage due to misuse or procedural violations by improper use or commis-
sioning. The product may only be operated by trained and autho-
rized personnel under observation of all safety instructions. Safe and correct operation and operational safety of the product is subject to operation according to its intended use according to the provisions of these operating and installati-
on instructions. The intended use includes observance and compliance of all safety instructions included in these operating instruc-
tions and all applicable regulations by the trade association and applicable laws for environmental protection. The inten-
ded use also includes compliance of all company regulati-
ons included in these operating and installation instructions. 2.3 Foreseeable misuse Foreseeable misuse includes operating the product not in accordance with the intended use approved by the manu-
facturer elero GmbH Antriebstechnik (refer to Address). 2.4 Warranty and liability Generally, the general terms and conditions of sale and delivery of the manufacturer elero GmbH Antriebstechnik
(refer to Address) apply. The terms and conditions of sale and delivery are part of the sales documentation and are handed over to the operator on delivery. Liability claims for personal and property damage are excluded if such dama-
ge is due to one or several of the following causes:
Opening the product by the customer Improper use of the product Incorrect installation, commissioning or operation of the product Structural changes to the product without the written approval of the manufacturer Operating the product with incorrectly installed connec-
tions, defective safety equipment or with not properly installed safety and protective equipment Failure to observe the safety regulations and instructions included in these operating instructions Safety 3 3.1 General safety instructions These operation and installation instructions include all safety instructions for prevention and avoiding of dangers during handling of the product over its entire life cycles. Compliance with all speci ed safety instructions ensures safe operation of the product. 3.2 Layout of safety instructions The safety instructions in this document are marked by dan-
ger signs and safety symbols and are designed according to the SAFE principle. They include information on type and source of the danger as well as on possible consequences and on prevention of the danger. The following table de nes the design and description of the levels of danger with potential physical injuries as they are used in these operating instructions. Symbol Signal word DANGER Description Warns of a potential ac-
cident with if instructions are not complied with leading to life-threatening, irreversible injuries or death. WARNING Warns of a potential ac-
cident with if instructions are not complied with lea-
ding to severe, potentially life-threatening, irreversib-
le injuries or death. CAUTION Warns of a potential ac-
cident with if instructions are not complied with leading to light, reversible injuries. Fig. 1 Notation of personal injury The following table describes symbols used in these ope-
rating instructions for illustration of dangerous situations in connection with the respective symbol for the level of danger. Symbol Description Danger due to voltage, electrical shock:
This symbol indicates dangers due to electricity. Fig. 2 Notation of a speci c danger The following table de nes the illustration and description of situations in these operating instructions that may lead to damage to the product or indicates facts, conditions, tips and information. Non-compliance with the speci ed technical data 2.5 Customer service of the manufacturer In case of a defect, the product may only be repaired by the manufacturer. Please refer to section Address for the return address of the customer service. If you did not acquire the product directly from elero, please contact your supplier. 2 | US+CA elero GmbH Description 3.4 General obligations of the operator Safety Symbol Signal word NOTE IMPOR-
TANT This symbol warns of po-
tential property damage. This symbol indicates important facts and con-
ditions as well as further information in these operating and installation instructions. Additionally, it refers to certain inst-
ructions giving additional information or helping you to perform a task. Fig. 3 Notation of property damage and additional informa-
tion The following example illustrates the general layout of a safety instruction:
SIGNAL WORD Type and source of danger Description of the type and source of danger Measures for prevention of the danger. 3.3 General safety principles The product was designed according to the state-of-the-art and recognized safety-related rules and is safe for opera-
tion. During product design, basic safety and health requi-
rements of applicable laws, standards and guidelines were observed. The safety of the product is con rmed by the EC Declaration of Conformity. All information on safety refer to currently applicable direc-
tives of the European Union. Operators in other countries must ensure that applicable local laws and regulations are observed. Apart from the safety instructions in these operating inst-
ructions, generally applicable regulations on prevention of accidents and environmental protection must be observed. The product must only be used in technically awless condi-
tion and for proper safety-conscious and risk-conscious use while observing the operating instructions. The product is designed for operation according to section intended use. Operation of the product not according to its intended use may lead to danger for life and limb of the user and third parties or cause damage to the machine and other proper-
ties. The manufacturer must be immediately and directly in-
formed on accidents or near misses during operation of the product that caused or may have caused personal injuries and or damage to the working environment. All safety instructions in the operating instructions and on the product must be observed. Additionally to observing these safety instructions, the operator must ensure that all national and international regulations applicable in the country of operation and other binding regulations on ope-
rational safety, prevention of accidents and environmental protection are complied with. All work on the product must only performed by trained, safety-related instructed and authorized personnel. Appropriately quali ed personnel must observe all appli-
cable standards and regulations in the country of installation and inform the customer on the operating and maintenance requirements of the product. The operator is obliged to only operate the product in technically awless and operationally safe condition. The operator must ensure that apart from the safety instruc-
tions in the operating instructions, generally applicable regulations on safety and prevention of accidents, the provisions of DIN VDE 0100 as well as the regulations on environmental protection of the respective country of operation are observed and complied with. The operator is obliged to ensure that all work on the pro-
duct is carried out by trained and safety-related instructed and authorized personnel. Ultimately responsible for accident-free operation is the operator of the product or the personnel authorized by him. The operator is responsible for compliance of the tech-
nical speci cations particularly the statistic and dynamic load limits. Non-compliance with static load limits may lead to loss of the supporting or holding function. With respect to the intended use, the operator must ensu-
re dry, not too warm ambient conditions (building condi-
tions) under the in uence of radial heat. Deviations must be approved by the manufacturer. 3.5 General requirements on personnel Each person commissioned to work with the product must have read and understood the entire operating instructions prior to carrying out the respective work. This does also apply if the person has already worked with this kind of product or was trained on it. Before start of all work, the personnel has to be made aware of all dangers in connection with working on the product. All personnel commissioned to work with the product must have no physical limitations temporarily or perma-
nently in uencing their attention or good judgment (e. g. by fatigue). Handling the product or any assembly, disassembly and cleaning by minors or under the in uence of alcohol, drugs or medication is not permitted. Personnel must wear appropriate personal protective equipment according to the work to be carried out and the present work environment. Children must not play with xed control panels. Keep remote controls away from children. Observe moving roller shutters and keep persons on a distance until the shutter has properly closed. 3.6 Safety instructions on technical condition Prior to installation the product must be checked for damage and proper condition. The operator is obliged to only operate the product in technically awless and operationally safe condition. The technical condition must comply with statutory require-
ments applicable at the date of manufacturing stated on the name plate. If dangers for personnel or changes in the operational behavior are identi ed, the product must be put out of operation immediately and the operator must be informed on the incident. Without approval by the manufacturer, no modi cation, extensions or alterations must be carried out on the product. elero GmbH US+CA | 3 Product description | Installation The system must be regularly checked for imbalance or signs of wear or damaged cables and springs (if appli-
cable). 3.7 Safety instructions on transport, assembly and installation In general, the respective transport company is responsible for transporting the product. The following safety require-
ments must be observed during transport, assembly and installation of the product:
During transport, the product must be secured according to the regulations of the used means of transport. For transport, only hoisting equipment and suspension gear must be used that are appropriately dimensioned for safely handling the forces occurring during loading, unloading and assembly of the product. Only points de ned for hoisting or suspension at the pallet and the product must be used for hoisting or sus-
pension. If work must be carried out under suspended parts or working equipment, these must be secured against falling by suitable means. It must be ensured by suitable hois-
ting equipment that loads drift unintentionally, fall or get unhooked unsupervised. Standing under suspended loads is forbidden. During loading with hoisting equipment, a safety helmet must be worn. Assembly and installation must generally only be carried out by trained and suitably instructed specialists. The rated torque and the rated operating time must be suitable for the properties of the driven component (fa-
bric). The smallest internal tube diameter for the winding shaft is 36 mm for RolTop type S, 47 mm for RolTop type M and 58 mm for RolTop type L. Access to the drive system must be ensured by a freely accessible appropriately sized inspection ap that can easily be opened. 3.8 Safety instructions on operation Before initial commissioning, the operator is obliged to inspect the product for safe and proper operation. Inspections must also be carried out during operation of the product in regular intervals de ned by the operator. 3.9 Safety instructions on electrical installation Work on the electric system of the used equipment must only be carried out by authorized electricians according to applicable rules and regulations by the trade association, particularly the provisions of DIN VDE 0100. Additionally, the national legal regulations of the respective country of operation must be observed. In case of defects like loose connections or defective or damaged cables on the system, the product must not put into operation. Prior to any inspection, installation or disassembly work, the system (blinds, shutter) must be disconnected from the voltage. All electrical connections, safety equipment, safeguards etc. must be properly installed, connected and grounded. The power connection must be designed according to the information in the electrical circuit diagram (type and level of voltage). One circuit breaker is suf cient to disconnect the system from the mains supply (if only one phase and neutral is used). If one xed (stationary installed) drive system is not equipped with a mains cable with plug or other means of disconnection from the mains supply with a contact opening width according to the provisions of overvoltage category II (according to IEC 60664-1) for full disconnect, an isolating device of this kind must be installed into the xed electrical installation according to the installation regulations. Mains connection cables for drive systems with rubber hose cables (code 60245 IEC 53) must always be repla-
ced by cables of the same type. The following applies for drive systems with access to unprotected, movable parts after installation: Movable parts of the drive system must be installed at least 2.5 m above the ground (or another level providing access to the drive system). 4 Product description The RolTop is a electromechanical tubular motor drive. During operation it carries out radial movements. Commissioning of the RolTop with elero installation cable for setting of various functions. Fabric protection system with retraction Fabric relief function (fabric protection system) The values for your RolTop model can be found on the name plate. Depending on torque and size, the different models of the RolTop are equipped with different types of braking sys-
tems. This may lead to different operating properties e. g. when approaching end positions. 5 Installation CAUTION Risk of injury due to hot surfaces. The drive system gets hot during operation, therefore the housing may be hot. Risk of skin burns. Wear personal protective equipment (protective gloves). Due to potential material defects, a broken gear unit, drive or coupling defect may cause injuries from impacts or shocks. For design of the system, suitable materials were used and a sampling test in form of a double load test accor-
ding to DIN EN 60335-2-97 was carried out. Risk of injury from impacts or shocks due to incorrectly installed or not properly engaged motor bearings. Risk due to insufficient stability and stored energy (gravity). Selection of motor bearings according to torque speci -
cations. The drive system must be secured with all provided safety equipment. Inspection for proper engagement on the motor bearing and correct screw tightening torques. WARNING Risk of injury due to electricity. Risk of electric shock. Electrical work must only be carried out by authorized electricians. 4 | US+CA elero GmbH Mechanical mounting | Electrical connection Risk of injury due to electricity. Potential risk from parts that have become live due to a malfunction. The electrical connection including wiring is described in the operating and installation instructions. CAUTION Risk of injury due to malfunctions due to incorrect installa-
tion. Excessive winding of the drive system leads to possible destruction of system parts. For safe operation, end positions must be set / program-
med. Training courses by the manufacturer for specialized companies. NOTE Power supply failure, braking of machine components and other defects. For safe operation, the system must be properly installed and the end positions must be set on commissioning. Damage to the RolTop by humidity ingress. On protection class IP44 systems, all cables or plugs must be protected against ingress of humidity. This action must be taken immediately after removing the RolTop from its original packaging. The drive system must be installed in a position safe from rain. Important On delivery (factory settings), the RolTop is in commissio-
ning mode. It is necessary to set the end positions
(refer to section 5.6). 5.1 Mechanical mounting Important preliminary consideration:
The working space around the installed drive system is often limited. Therefore, get an overview of the implementa-
tion of the electrical connection (refer to section 5.2) prior to the mechanical installation and carry out respective chan-
ges, if necessary. NOTE Damage to electrical lines by pressure or tensile loads. All electrical lines must be laid safe from pressure or tensile loads. Observe the bending radius of the cables (at least 50 mm). Lay connection cables in a loop downwards to prevent water from running into the system. Damage to the drive system by impact loads. Always slide the drive system onto the shaft. Never ham-
mer onto the shaft or the drive system!
Never drop the drive system!
Damage to or destruction of the drive system by drilling. Never drill into the drive system!
Important Attach the RolTop only to the provided mounting elements. Firmly mounted control units must be visible attached. The fabric must be mounted on the winding shaft. The pro le tube must have suf cient clearance to the motor tube. Make sure there is suf cient axial play (1 - 2 mm). Installation in pro le tubes Push the drive with suitable adapter and driving collar into the profile tube. Protect the motor cable in order to avoid damage from the driven com-
ponent. A B Secure the counterbearings to pre-
vent axial movement, e. g. screw or rivet on shaft carrier. Axially secure the drive in the bea-
ring!
Attach the fabric to the shaft!
5.2 Electrical connection C WARNING Danger to life due to incorrect electrical connection. Risk of electric shock. Before initial commissioning, check the correct connec-
tion of the PE conductor. NOTE Damage to the RolTop due to incorrect electrical connec-
tion. Before initial commissioning, check the correct connec-
tion of the PE conductor. Damage to or destruction of the RolTop due to ingress of humidity. For devices with protection class IP44, the customer-
provided connection of cables or plugs (wiring) must also be compliant with protection class IP44. Damage to or destruction of the RolTop for models with 120 V 1 AC due to incorrect control. Switches that are preset to OFF (dead man) for drive systems must be mounted in viewing range of the RolTop but away from moving parts and at a height above 1.5 m. Important For electrical connection, generally no connection and dis-
connection of the connection cable or plug is necessary. Particularly at the RolTop type S and depending on the used mounting or adapter plate, it is necessary to remove this screwed plate before replacing cables. Only connect when the system is disconnected from the voltage. To do so, disconnect the drive cable. 1 Use a suitable screwdriver to push the locking mecha-
nism of the device plug to the cable. 2 Disconnect the plug. 3 Insert the device plug until the locking mechanism enga-
ges. Removing and inserting the device plug Delivery con-
dition Remove plug Insert plug 2 1 3 Fig. 4 Removing and inserting the device plug elero GmbH US+CA | 5 Installation: Electrical connection | End position settings Press one of the drive buttons until the drive system indica-
tes switchover to setting mode with a short automatic stop. Now, you can set the end positions. After setting both end positions, the setting mode is closed. 5.6.1 Relief function for end position(s) If one end position was programmed to limit stop, an additi-
onal relief function can be activated for the fabric. Important Activation of the relief function (for options B to D) is carried out in one step with programming of the end positions (refer to sections 5.6.7 to 5.6.9)!
5.6.2 Relief function at the upper stop For option B (refer to section 5.6.7) and option C (refer to section 5.6.8):
Activating the relief function at the upper limit stop 1 Using the installation cable, keep the UP button pressed from step (section 5.6.7 and 5.6.8) and press additionally (simultaneously) the DOWNbutton
. Keep both buttons pressed until the fabric stops. The relief function at the upper limit stop is activated. 5.6.3 Relief function at the lower stop For option C (refer to section 5.6.8) and option D (refer to section 5.6.9):
Activating the relief function at the lower limit stop 1 Using the installation cable, keep the DOWN button pressed from step (section 5.6.8 and 5.6.9) and press additionally (simultaneously) the UPbutton
.Keep both buttons pressed until the fabric stops. The relief function at the lower limit stop is activated. 5.6.4 Changing / deleting of end positions and deleting the relief function It is not possible to change or delete one individual end position. This is always carried out in pairs (upper and lower end position at once). By deleting the end positions, also the setting of the optio-
nal relief function is lost. Important Complete, uninterrupted up and down movement is neces-
sary to adapt the fabric protection system to the fabric. elero Changing / deleting of end positions 1 In a medium fabric position, using the installation cable, simultaneously press both direction buttons (
and ) and keep them pressed until the drive system brie y moves up and down. Deleting the end position settings is completed. The end positions can be reset. 5.3 Connection example, RolTop 120 V / 60 Hz 1 2 3 4 1 Winding thermostat 2 Device switch 3 Junction box 4 Switch box 5 Shutter switch /
Shutter button 6 Electronic 7 Condenser sw br bl gr/ge black brown blue green / yellow w s r b l b e g
r g 7 6 5 1 0 2 L1 N PE 3 2 1 3 2 1 Fig. 5 Circuit diagram RolTop 120 V / 60 Hz and Wiring when using a Hirschmann plug connection STAS-3 Important The motor controls in up and down direction must be inter-
locked. 5.4 Parallel connection Important You can connect several RolTop systems in parallel. To do so, please observe the maximum control capacity. 5.5 Commissioning Important On delivery, the drive system is set to commissioning mode. It is necessary to set the end positions with the elero installation cable. Connecting the installation cable is only for commissio-
ning of the drive system and for con guration. Blau (Neutralleiter) (1) Schwarz (2) Braun (3) Grn-gelb Blau (Neutralleiter) (1) Schwarz (2) Braun (3) Grn-gelb Fig. 6 Installation cable connection Switch on power supply. Now, you can set the end positions with the elero instal-
lation cable. 5.6 End position and relief settings Important preliminary consideration:
Before carrying out the end position settings, decide on a certain relief function (different combinations available according to the following models). This will save you unnecessary time and effort during con-
guration!
6 | US+CA elero GmbH Relief function | End position settings 5.6.5 Four options for end position settings 5.6.7 Option B: Fixed upper end position, Four different combinations of end position settings are available that can be selected according to the technical requirements of the fabric. End position settings
(4 options) A Upper and lower end positi-
on freely con gurable B Fixed upper end position, lower end position freely con gurable C Fixed upper and lower end position D Upper end position freely con gurable, xed lower end position possible with Suspension spring, bands, belt Suspension spring, bands, belt, limit plug, angle bracket Anti-lift device, xed shaft connector, limit plug, angle bracket Anti-lift device Fig. 7 Options of end position settings for RolTop 5.6.6 Option A: Upper and lower end position freely con gurable Option A:
Upper and lower end position freely con gurable In a medium fabric position, using the installation cable, press the UP button until the fabric has reached the desired upper end position. The drive system starts, stops brie y and starts again (as long as the UP button is pressed). Corrections can be made with the buttons and
. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Press the DOWN button again, until the fabric has reached the desired lower end position. The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). Corrections can be made with the buttons and
. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. End position setting of option A is completed. Fig. 8 End position setting option A:
lower end position freely con gurable Option B: Fixed upper end position, lower end position freely con gurable In a medium fabric position, using the installation cable, press the UP button until the fabric has reached the desired upper end position (to upper limit stop). The drive system starts, stops brie y and starts again (as long as the UP button is pressed). The drive system automatically stops when reaching the upper limit stop. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Optional: Activation of the relief function for the upper limit stop: refer to section 5.6.2. Press the DOWN button again, until the fabric has reached the desired lower end position. The drive system starts, stops brie y and starts again (as long as the button is pressed). Corrections can be made with the buttons and
. Keep the UP button pressed until the drive sys-
tem stops automatically. End position setting of option B is completed. Fig. 9 End position setting option B:
5.6.8 Option C:
Fixed upper and lower end position Option C: Fixed upper and lower end position In a medium fabric position, using the installation cable, press the UP button until the fabric has reached the desired upper end position (to upper limit stop). The drive system starts, stops brie y and starts again (as long as the UP button is pressed). The drive system automatically stops when reaching the upper limit stop. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Optional: Activation of the relief function for the upper limit stop: refer to section 5.6.2. Press the DOWN button again, until the fabric has reached the lower end position (to bottom limit stop). The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). The drive system automatically stops when reaching the lower limit stop. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option C is completed. Fig. 10 End position setting option C:
elero GmbH US+CA | 7 End position settings | Troubleshooting | Repair 5.6.9 Option D:
Upper end position freely con gurable, xed lower end position Option D: Upper end position freely con gurable, xed lower end position In a medium fabric position, using the installation cable, press the UP button until the fabric has reached the desired upper end position. The drive system starts, stops brie y and starts again (as long as the button is pressed). Corrections can be made with the buttons and
. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Press the DOWN button again, until the fabric has reached the lower end position (to bottom limit stop). The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). The drive system automatically stops when reaching the lower limit stop. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option D is completed. Fig. 11 End position setting option D:
5.7 Technical data The separately available technical data sheet will provide you with an overview of the most important technical para-
meters. Troubleshooting 6 Problem /
malfunction Drive system stops during movement Remedy, correction Set end posi-
tions Possible cause End positions not correctly set Drive system is in setting mode Drive system stops after a short period of time End positions have been saved Stiff fabric Connection error Drive system only runs in one direction Drive system does not react Set second end position Check smooth running of the fabric Check connec-
tion No power supply Temperature limiter has triggered Check power supply Have the drive system cool down Problem /
malfunction Program-
ming of end positions not possible Possible cause Random drive movements The distance to the end position or to the limit stop is too short Remedy, correction Delete end positions Reset end positions The drive sys-
tem must run, stop brie y and start again
(as long as a button on the installa-
tion cable is pressed). Fig. 12 RolTop troubleshooting 7 8 Servicing The RolTop is maintenance-free. Cleaning WARNING Risk of injury due to electricity. Risk of electric shock. Risk due to potential live parts. Only carry out cleaning when the system is disconnected from the voltage. To do so, disconnect the drive cable. Clean the product surface only with a soft, clean and dry cloth. Repair 9 In case of questions, please contact your local specialist. Please always provide the following information:
Article number and designation on name plate Type of defect Previous and unusual occurrences Circumstances Own assumption 10 Address elero GmbH Antriebstechnik Linsenhofer Str. 65 72660 Beuren Germany Phone: +49 7025 13-01 Fax:
+49 7025 13-212 info@elero.de www.elero.com If you require a contact outside of Germany, please visit our website. 11 Disassembly and disposal After unpacking the system, dispose of the packaging mate-
rial according to applicable regulations. After the last use, dispose of the product according to appli-
cable regulations. Environmental information No unnecessary packaging material was used. Packaging can be separated into three material types: Cardboard
(carton), polystyrene (padding) and polyethylene (bag, protective foam foil). 8 | US+CA elero GmbH EC Declaration of Conformity | UL approval | Homologation UL 13 US: Addendum to the manual UL approval This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following thwo conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference recieved, inclu-
ding interference that may cause undesired operation. Any changes or modi cations made to this device without the express permission of the manufacturer may void the users authority to operate this device. 14 CA: Addendum au manuel Homologation UL Le prsent appareil est conforme aux CNR-210 (et FCC part 15) dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. The device consists of materials that can be recycled if it is disassembled by a specialized company. Please observe local regulations on disposal of packaging material and old equipment. During disassembly additional risks may occur that do not arise during operation. WARNING Risk of injury due to electricity. Risk of electric shock. Physically disconnect the energy supply cables and discharge stored energy. Wait for at least 5 minutes after switching off until the motor has cooled down and the capacitors have lost their voltage. For disassembly above body height, use suitable, appro-
ved and stable climbing aids. Any electrical work must only be performed by person-
nel speci ed in section Safety instructions on electrical installation. Scrapping When scrapping the product, applicable international, natio-
nal and local rules and regulations must be complied with. Please observe the recycling and dismantling properties of materials and components as well as environmental and health risks during recycling and disposal. CAUTION Environmental damage due to incorrect disposal Electrical scrap and electronic components are subject to hazardous waste treatment and may only be disposed of by approved specialists. Material groups like different plastics and metals must be sorted and put into the recycling system or disposed of. Disposal of electrotechnical and electrical components Disposal and recycling of electrotechnical and electrical components must be carried out according to the applicable laws or national regulations. 12 EC Declaration of Conformity EG-KONFORMITTSERKLRUNG Wir erklren hiermit, dass das/die nachfolgend genannte/n Produkt/e der Maschinenrichtlinie 2006/42/EG entspricht/entsprechen. Produktbezeichnung: Rohrmotor RolTop S (120V/60Hz) alle Varianten RolTop M (120V/60Hz) alle Varianten Beschreibung:
Einsteckantrieb fr Rolllden Die bereinstimmung der/s bezeichneten Produkte/s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen bercksichtigt:
EMV-Richtlinie 2004/108/EG Niederspannungsrichtlinie 2006/95/EG DIN EN 60335-2-97 (VDE 0700-97):2009 DIN EN 14 202:2004 Beuren, 31.05.2012 Ralph Trost
-CE-Beauftragter-, -Doku-Bevollmchtigter-
Fig. 13 EC Declaration of Conformity RolTop type S and M elero GmbH US+CA | 9 elero GmbH Antriebstechnik Linsenhofer Strae 65 D-72660 Beuren Phone: +49 7025 13-01 Fax: +49 7025 13-212 info@elero.de www.elero.com Technical modifications reserved
1 | RolTop 2 | Users Manual | 1.51 MiB | September 08 2013 |
Roller shutter drive RolTop-915 120 V / 60 Hz Table of contents 1 2 2.1 2.2 2.3 Operating and installation instructions General information Standards and guidelines Intended use Foreseeable misuse 2.4 Warranty and liability 2.5 Customer service of the manufacturer 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 5 5.1 5.2 5.3 5.4 5.5 Safety General safety instructions Layout of safety instructions General safety principles General obligations of the operator General requirements on personnel Safety instructions on technical condition Safety instructions on transport, assembly and installation Safety instructions on operation Safety instructions on electrical installation Product description Installation Mechanical mounting Electrical connection Connection example, RolTop-915 120 V / 60 Hz Parallel connection Commissioning 5.5.1 Installation cable connection 5.5.2 Wireless connection (transmitter operation) 5.6 End position and relief settings 5.6.1 Relief function for end position(s) 5.6.2 Relief function at the upper stop 5.6.3 Relief function at the lower stop 5.6.4 Changing / deleting of end positions and deleting the relief function 5.6.5 Programming or deleting additional fabric positions 5.6.6 Four options for end position settings 5.6.7 Option A: Upper and lower end position freely con gurable 1 1 2 2 2 2 2 2 2 2 3 3 3 4 4 4 4 4 5 5 6 6 6 6 6 7 7 7 7 7 7 7 7 8 5.6.8 Option B:
Fixed upper end position, lower end position freely con gurable 5.6.9 Option C:
Fixed upper and lower end position 5.6.10 Option D: Upper end position freely con gurable, xed lower end position 8 5.7 5.8 5.9 6 7 8 9 10 11 12 13 14 Transmitter programming Programming additional transmitters(s) Technical data Troubleshooting Servicing Cleaning Repair Address Disposal / scrapping EC Declaration of Conformity US: Addendum to the manual UL approval CA: Addendum au manuel Homologation UL Roller shutter drive RolTop-915 120V / 60Hz 1 Operating and installation instructions 8 8 9 9 9 9 9 9 10 10 10 10 10 10 2 Please keep these operating instructions for later use and have them available during the complete service life of the product!
The German version of these operating instructions is the original version. All foreign language documents are translations of the original version. All rights reserved with regard to patent claim or submission of design or utility patent. General information The structure of these operating instructions is based on the service life phases of the electrical drive (subsequently referred to as product). The manufacturer reserves the right to make changes to the technical data included in these operating instructions. The-
se may deviate from the respective model of the product while the factual information are generally not changed and are not losing their validity. The current state-of-the-art can be obtained from the manufacturer at all times. Potential claims cannot be asserted. Deviations from text and pictori-
al statements are not possible and depending on the tech-
nical development, setup and accessories of the product. Deviating information on special models are included by the manufacturer in the sales documentation. Other information shall remain unaffected by this. 138186606_US+CA_0513 Standards and guidelines | Safety 2.1 Standards and guidelines 2.2 During system design, basic safety and health requirements of applicable laws, standards and guidelines were obser-
ved. The safety is con rmed by means of the Declaration of Conformity (refer to EC Declaration of Conformity). All safety information in these operating instructions are based on currently applicable laws and regulations in Germany. All information in the operating instructions must be obser-
ved at all times. Apart from the safety instructions in these operating instructions, applicable local regulations on pre-
vention of accidents, environmental protection and occupa-
tional safety must be observed. Regulations and standards for safety assessment can be found in the EC Declaration of Conformity. Intended use This product is intended for use in facade construction for driving electrical sun protection devices. Decisive for the determination of the drive system is the elero drive computation program (http://elero.com/
en;service;drive-computation-program.htm). Other applications must be approved in advance by the ma-
nufacturer elero GmbH Antriebstechnik (refer to Address). The operator alone is liable for all damage due to improper use of the product. The manufacturer does not assume any liability for personal injuries and property damage due to misuse or procedural violations by improper use or commis-
sioning. The product may only be operated by trained and autho-
rized personnel under observation of all safety instructions. Safe and correct operation and operational safety of the product is subject to operation according to its intended use according to the provisions of these operating and installati-
on instructions. The receiver must only be connected with equipment and systems approved by the manufacturer. The operator is not protected against interference by other wireless systems and terminal equipment (e. g. also by means of wireless systems) that are properly operated within the same fre-
quency range. Wireless systems must not be operated in areas with increased interference factor (e. g. hospitals, airports etc.). Remote control is only allowed for equipment and systems if malfunctions in hand/wall transmitters or receivers do not lead to damage for personnel, animals or property or if this risk is covered by other safety installati-
ons. The intended use includes observance and compliance of all safety instructions included in these operating instruc-
tions and all applicable regulations by the trade association and applicable laws for environmental protection. The inten-
ded use also includes compliance of all company regulati-
ons included in these operating and installation instructions. 2.3 Foreseeable misuse Foreseeable misuse includes operating the product not in accordance with the intended use approved by the manu-
facturer elero GmbH Antriebstechnik (refer to Address). 2.4 Warranty and liability Generally, the general terms and conditions of sale and delivery of the manufacturer elero GmbH Antriebstechnik
(refer to Address) apply. The terms and conditions of sale and delivery are part of the sales documentation and are handed over to the operator on delivery. Liability claims for personal and property damage are excluded if such dama-
ge is due to one or several of the following causes:
Opening the product by the customer Improper use of the product 2 | US+CA elero GmbH Incorrect installation, commissioning or operation of the product Structural changes to the product without the written approval of the manufacturer Operating the product with incorrectly installed connec-
tions, defective safety equipment or with not properly installed safety and protective equipment Failure to observe the safety regulations and instructions included in these operating instructions Non-compliance with the speci ed technical data 2.5 Customer service of the manufacturer In case of a defect, the product may only be repaired by the manufacturer. Please refer to section Address for the return address of the customer service. If you did not acquire the product directly from elero, please contact your supplier. Safety 3 3.1 General safety instructions These operation and installation instructions include all safety instructions for prevention and avoiding of dangers during handling of the product over its entire life cycles. Compliance with all speci ed safety instructions ensures safe operation of the product. 3.2 Layout of safety instructions The safety instructions in this document are marked by dan-
ger signs and safety symbols and are designed according to the SAFE principle. They include information on type and source of the danger as well as on possible consequences and on prevention of the danger. The following table de nes the design and description of the levels of danger with potential physical injuries as they are used in these operating instructions. Symbol Signal word DANGER Description Warns of a potential ac-
cident with if instructions are not complied with leading to life-threatening, irreversible injuries or death. WARNING Warns of a potential ac-
cident with if instructions are not complied with lea-
ding to severe, potentially life-threatening, irreversib-
le injuries or death. CAUTION Warns of a potential ac-
cident with if instructions are not complied with leading to light, reversible injuries. Fig. 1 Notation of personal injury The following table describes symbols used in these ope-
rating instructions for illustration of dangerous situations in connection with the respective symbol for the level of danger. Safety Symbol Description Danger due to voltage, electrical shock:
This symbol indicates dangers due to electricity. Fig. 2 Notation of a speci c danger The following table de nes the illustration and description of situations in these operating instructions that may lead to damage to the product or indicates facts, conditions, tips and information. all national and international regulations applicable in the country of operation and other binding regulations on ope-
rational safety, prevention of accidents and environmental protection are complied with. All work on the product must only performed by trained, safety-related instructed and authorized personnel. Appropriately quali ed personnel must observe all appli-
cable standards and regulations in the country of installation and inform the customer on the operating and maintenance requirements of the product. 3.4 General obligations of the operator Symbol Signal word NOTE IMPOR-
TANT Description This symbol warns of po-
tential property damage. This symbol indicates important facts and con-
ditions as well as further information in these operating and installation instructions. Additionally, it refers to certain inst-
ructions giving additional information or helping you to perform a task. Fig. 3 Notation of property damage and additional informa-
tion The following example illustrates the general layout of a safety instruction:
SIGNAL WORD Type and source of danger Description of the type and source of danger Measures for prevention of the danger. 3.3 General safety principles The product was designed according to the state-of-the-art and recognized safety-related rules and is safe for opera-
tion. During product design, basic safety and health requi-
rements of applicable laws, standards and guidelines were observed. The safety of the product is con rmed by the EC Declaration of Conformity. All information on safety refer to currently applicable direc-
tives of the European Union. Operators in other countries must ensure that applicable local laws and regulations are observed. Apart from the safety instructions in these operating inst-
ructions, generally applicable regulations on prevention of accidents and environmental protection must be observed. The product must only be used in technically awless condi-
tion and for proper safety-conscious and risk-conscious use while observing the operating instructions. The product is designed for operation according to section intended use. Operation of the product not according to its intended use may lead to danger for life and limb of the user and third parties or cause damage to the machine and other proper-
ties. The manufacturer must be immediately and directly in-
formed on accidents or near misses during operation of the product that caused or may have caused personal injuries and or damage to the working environment. All safety instructions in the operating instructions and on the product must be observed. Additionally to observing these safety instructions, the operator must ensure that The operator is obliged to only operate the product in technically awless and operationally safe condition. The operator must ensure that apart from the safety instruc-
tions in the operating instructions, generally applicable regulations on safety and prevention of accidents, the provisions of DIN VDE 0100 as well as the regulations on environmental protection of the respective country of operation are observed and complied with. The operator is obliged to ensure that all work on the pro-
duct is carried out by trained and safety-related instructed and authorized personnel. Ultimately responsible for accident-free operation is the operator of the product or the personnel authorized by him. The operator is responsible for compliance of the tech-
nical speci cations particularly the statistic and dynamic load limits. Non-compliance with static load limits may lead to loss of the supporting or holding function. With respect to the intended use, the operator must ensu-
re dry, not too warm ambient conditions (building condi-
tions) under the in uence of radial heat. Deviations must be approved by the manufacturer. 3.5 General requirements on personnel Each person commissioned to work with the product must have read and understood the entire operating instructions prior to carrying out the respective work. This does also apply if the person has already worked with this kind of product or was trained on it. Before start of all work, the personnel has to be made aware of all dangers in connection with working on the product. All personnel commissioned to work with the product must have no physical limitations temporarily or perma-
nently in uencing their attention or good judgment (e. g. by fatigue). Handling the product or any assembly, disassembly and cleaning by minors or under the in uence of alcohol, drugs or medication is not permitted. Personnel must wear appropriate personal protective equipment according to the work to be carried out and the present work environment. Children must not play with xed control panels. Keep remote controls away from children. Observe moving roller shutters and keep persons on a distance until the shutter has properly closed. elero GmbH US+CA | 3 Safety | Product description 3.6 Safety instructions on technical condition Prior to installation the product must be checked for damage and proper condition. The operator is obliged to only operate the product in technically awless and operationally safe condition. The technical condition must comply with statutory require-
ments applicable at the date of manufacturing stated on the name plate. If dangers for personnel or changes in the operational behavior are identi ed, the product must be put out of operation immediately and the operator must be informed on the incident. Without approval by the manufacturer, no modi cation, extensions or alterations must be carried out on the product. The system must be regularly checked for imbalance or signs of wear or damaged cables and springs (if appli-
cable). 3.7 Safety instructions on transport, assembly and installation In general, the respective transport company is responsible for transporting the product. The following safety require-
ments must be observed during transport, assembly and installation of the product:
During transport, the product must be secured according to the regulations of the used means of transport. For transport, only hoisting equipment and suspension gear must be used that are appropriately dimensioned for safely handling the forces occurring during loading, unloading and assembly of the product. Only points de ned for hoisting or suspension at the pallet and the product must be used for hoisting or sus-
pension. If work must be carried out under suspended parts or working equipment, these must be secured against falling by suitable means. It must be ensured by suitable hois-
ting equipment that loads drift unintentionally, fall or get unhooked unsupervised. Standing under suspended loads is forbidden. During loading with hoisting equipment, a safety helmet must be worn. Assembly and installation must generally only be carried out by trained and suitably instructed specialists. The rated torque and the rated operating time must be suitable for the properties of the driven component (fa-
bric). Decisive for the determination of the drive system is the drive computation program of the manufacturer. The smallest internal tube diameter for the winding shaft is 36 mm for RolTop-915 type S, 47 mm for RolTop-915 type M and 58 mm for RolTop-915 type L. Access to the drive system must be ensured by a freely accessible appropriately sized inspection ap that can easily be opened. 3.8 Safety instructions on operation Before initial commissioning, the operator is obliged to inspect the product for safe and proper operation. Inspections must also be carried out during operation of the product in regular intervals de ned by the operator. 3.9 Safety instructions on electrical installation Work on the electric system of the used equipment must only be carried out by authorized electricians according to applicable rules and regulations by the trade association, particularly the provisions of DIN VDE 0100. Additionally, the national legal regulations of the respective country of operation must be observed. In case of defects like loose connections or defective or damaged cables on the system, the product must not put into operation. Prior to any inspection, installation or disassembly work, the system (blinds, shutter) must be disconnected from the voltage. All electrical connections, safety equipment, safeguards etc. must be properly installed, connected and grounded. The power connection must be designed according to the information in the electrical circuit diagram (type and level of voltage). One circuit breaker is suf cient to disconnect the system from the mains supply (if only one phase and neutral is used). If one xed (stationary installed) drive system is not equipped with a mains cable with plug or other means of disconnection from the mains supply with a contact opening width according to the provisions of overvoltage category II (according to IEC 60664-1) for full disconnect, an isolating device of this kind must be installed into the xed electrical installation according to the installation regulations. Mains connection cables for drive systems with rubber hose cables (code 60245 IEC 53) must always be repla-
ced by cables of the same type. The following applies for drive systems with access to unprotected, movable parts after installation: Movable parts of the drive system must be installed at least 2.5 m above the ground (or another level providing access to the drive system). 4 Product description The RolTop-915 is a wireless-controlled electromechanical tubular motor drive. During operation it carries out radial movements. Commissioning of the RolTop-915 with elero installation cable or transmitter for con guration of various functions. Fabric protection system with retraction Fabric relief function (Fabric protection system) Relief function and retraction for fabric protection are only active in wireless operation. The values for your RolTop-915 model can be found on the name plate. Depending on torque and size, the different models of the RolTop-915 are equipped with different types of braking systems. This may lead to different operating properties e. g. when approaching an end position. 4 | US+CA elero GmbH Optimum use of the wireless signal. Position the antenna as freely as possible and reposition it in case of bad reception. Do not bend, shorten or extent the antenna. Observe the minimum distance between two wireless drive systems of 15 cm. 5.1 Mechanical mounting Important preliminary consideration:
The working space around the installed drive system is often limited. Therefore, get an overview of the implementa-
tion of the electrical connection (refer to section 5.2) prior to the mechanical installation and carry out respective chan-
ges, if necessary. NOTE Damage to electrical lines by pressure or tensile loads. All electrical lines must be laid safe from pressure or tensile loads. Observe the bending radius of the cables (at least 50 mm). Lay connection cables in a loop downwards to prevent water from running into the system. Damage to the drive system by impact loads. Always slide the drive system onto the shaft. Never ham-
mer onto the shaft or the drive system!
Never drop the drive system!
Damage to or destruction of the drive system by drilling. Never drill into the drive system!
Important Attach the RolTop-915 only to the provided mounting ele-
ments. Firmly mounted control units must be visible attached. The fabric must be mounted on the winding shaft. The pro le tube must have suf cient clearance to the motor tube. Make sure there is suf cient axial play (1 - 2 mm). Installation in pro le tubes Push the drive with suitable adapter and driving collar into the profile tube. Protect the motor cable in order to avoid damage from the driven com-
ponent. A B Secure the counterbearings to pre-
vent axial movement, e. g. screw or rivet on shaft carrier. Axially secure the drive in the bea-
ring!
Attach the fabric to the shaft!
C Installation | Mechanical mounting 5 Installation CAUTION Risk of injury due to hot surfaces. The drive system gets hot during operation, therefore the housing may be hot. Risk of skin burns. Wear personal protective equipment (protective gloves). Due to potential material defects, a broken gear unit, drive or coupling defect may cause injuries from impacts or shocks. For design of the system, suitable materials were used and a sampling test in form of a double load test accor-
ding to DIN EN 60335-2-97 was carried out. Risk of injury from impacts or shocks due to incorrectly installed or not properly engaged motor bearings. Risk due to insufficient stability and stored energy (gravity). Selection of motor bearings according to torque speci -
cations. The drive system must be secured with all provided safety equipment. Inspection for proper engagement on the motor bearing and correct screw tightening torques. WARNING Risk of injury due to electricity. Risk of electric shock. Electrical work must only be carried out by authorized electricians. Risk of injury due to electricity. Potential risk from parts that have become live due to a malfunction. The electrical connection including wiring is described in the operating and installation instructions. CAUTION Risk of injury due to malfunctions due to incorrect installa-
tion. Excessive winding of the drive system leads to possible destruction of system parts. For safe operation, end positions must be set / program-
med. Training courses by the manufacturer for specialized companies. NOTE Power supply failure, braking of machine components and other defects. For safe operation, the system must be properly installed and the end positions must be set on commissioning. Damage to the RolTop-915 by humidity ingress. On protection class IP44 systems, all cables or plugs must be protected against ingress of humidity. This ac-
tion must be taken immediately after removing the Rol-
Top-915 from its original packaging. The drive system must be installed in a position safe from rain. Important On delivery (factory settings), the RolTop-915 is in commis-
sioning mode. It is necessary to set the end positions
(refer to section 5.6). elero GmbH US+CA | 5 Installation: Electrical connection 5.2 Electrical connection 5.3 Connection example, RolTop-915 120 V / 60 Hz WARNING Danger to life due to incorrect electrical connection. Risk of electric shock. Before initial commissioning, check the correct connec-
tion of the PE conductor. NOTE Damage to the RolTop-915 due to incorrect electrical con-
nection. Before initial commissioning, check the correct connec-
tion of the PE conductor. Damage to or destruction of the RolTop-915 due to ingress of humidity. For devices with protection class IP44, the customer-
provided connection of cables or plugs (wiring) must also be compliant with protection class IP44. Damage to or destruction of the RolTop-915 for models with 120 V 1 AC due to incorrect control. Switches that are preset to OFF (dead man) for drive systems must be mounted in viewing range of the Rol-
Top-915 but away from moving parts and at a height above 1.5 m. Important For electrical connection, generally no connection and dis-
connection of the connection cable or plug is necessary. Particularly at the RolTop915 type S and depending on the used mounting or adapter plate, it is necessary to remove this screwed plate before replacing cables. Only connect when the system is disconnected from the voltage. To do so, disconnect the drive cable. 1 Use a suitable screwdriver to push the locking mecha-
nism of the device plug to the cable. 2 Disconnect the plug. 3 Insert the device plug until the locking mechanism enga-
ges. Removing and inserting the device plug Delivery con-
dition Remove plug Insert plug 2 1 3 Fig. 4 Removing and inserting the device plug
w s r b l b e g
r g
1 Winding thermostat 2 Device plug 3 Junction box
(outside of roller shutter case) 4 Electronic 5 Condenser sw br bl gr/ge black brown blue green/yellow L1 N PE 3 2 1 Fig. 5 Circuit diagram RolTop-915 120 V / 60 Hz and Wiring when using a Hirschmann plug connection STAS-3 (with bridge) 5.4 Parallel connection Important You can connect several RolTop-915 systems in parallel. To do so, please observe the maximum control capacity. 5.5 Commissioning Important On delivery, the drive system is set to commissioning mode. It is necessary to set the end positions with the elero installation cable (refer to g. 6) or a elero wand/hand transmitter (refer to g. 7). Connecting the installation cable is only for commissio-
ning of the drive system and for con guration. 5.5.1 Installation cable connection blue (neutral) (1) black (2) brown (3) green-yellow Fig. 6 Installation cable connection Switch on power supply. Now, you can set the end positions with the elero instal-
lation cable. 6 | US+CA elero GmbH Relief function | End position settings 5.5.2 Wireless connection (transmitter operation) 5.6.3 Relief function at the lower stop ele r o Blue (neutral wire) (1) Black (2) Brown (3) Green-yellow (4) Fig. 7 Wireless connection (transmitter operation) Switch on power supply. The drive system moves up and down brie y. Now, the drive system is in wireless operation. Now, you can program the transmitter(s). 5.6 End position and relief settings Setting of end positions and relief can either be carried out by means of elero installation cable (ensure proper con-
nection according to section 5.5.1) or by means of a programmed transmitter. Programming a transmitter for a drive system is descri-
bed in section 5.7. Important preliminary consideration:
Before carrying out the end position settings, decide on a certain relief function (different combinations available according to the following models). This will save you unnecessary time and effort during con-
guration!
Press one of the drive buttons until the drive system indica-
tes switchover to setting mode with a short automatic stop. Now, you can set the end positions. After setting both end positions, the setting mode is closed. 5.6.1 Relief function for end position(s) If one end position was programmed to limit stop, an additi-
onal relief function can be activated for the fabric. Important The relief function is only active in wireless operation. Activation of the relief function (for options B to D) is carried out in one step with programming of the end positions (refer to sections 5.6.7 to 5.6.9)!
5.6.2 Relief function at the upper stop For option B (refer to section 5.6.7) and option C (refer to section 5.6.8):
Activating the relief function at the upper limit stop 1 Using the installation cable or a programmed trans-
mitter, keep the UP button pressed from step
(section 5.6.7 and 5.6.8) and press additionally
(simultaneously) the DOWNbutton . Keep both buttons pressed until the fabric stops. The relief function at the upper limit stop is activated. For option C (refer to section 5.6.8) and option D (refer to section 5.6.9):
Activating the relief function at the lower limit stop 1 In a medium fabric position, using the installation cable or a programmed transmitter, keep the DOWN button pressed from step (section 5.6.8 and 5.6.9) and press additionally (simultaneously) the UPbutton . Keep both buttons pressed until the fabric stops. The relief function at the lower limit stop is activated. 5.6.4 Changing / deleting of end positions and deleting the relief function It is not possible to change or delete one individual end position. This is always carried out in pairs (upper and lower end position at once). By deleting the end positions, also the setting of the optio-
nal relief function is lost. Important Complete, uninterrupted up and down movement is neces-
sary to adapt the fabric protection system to the fabric. Changing / deleting of end positions 1 In a medium fabric position, using the installation cable or a programmed transmitter, simultaneously press both direction buttons ( and ) and keep them pressed until the drive system brie y moves up and down. Deleting the end position settings is completed. The end positions can be reset. 5.6.5 Programming or deleting additional fabric positions Intermediate position programming:
refer to transmitter instructions. Ventilation position programming:
refer to transmitter instructions. Intermediate position deleting:
refer to transmitter instructions. Ventilation position deleting:
refer to transmitter instructions. 5.6.6 Four options for end position settings Four different combinations of end position settings are available that can be selected according to the technical requirements of the fabric. End position settings
(4 options) A Upper and lower end positi-
on freely con gurable B Fixed upper end position, lower end position freely con gurable C Fixed upper and lower end position D Upper end position freely con gurable, xed lower end position possible with Suspension spring, bands, belt Suspension spring, bands, belt, limit plug, angle bracket Anti-lift device, xed shaft connector, limit plug, angle bracket Anti-lift device elero GmbH Fig. 8 Options of end position settings for RolTop-915 US+CA | 7 End position settings 5.6.7 Option A: Upper and lower end position 5.6.9 Option C:
freely con gurable Fixed upper and lower end position Option A:
Upper and lower end position freely con gurable In a medium fabric position, using the installation cable or a programmed transmitter, press the UP button until the fabric has reached the desired upper end position. The drive system starts, stops brie y and starts again (as long as the UP button is pressed). Corrections can be made with the buttons and
. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Press the DOWN button again, until the fabric has reached the desired lower end position. The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). Corrections can be made with the buttons and
. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. End position setting of option A is completed. Fig. 9 End position setting option A:
5.6.8 Option B:
Fixed upper end position, lower end position freely con gurable Option B: Fixed upper end position, lower end position freely con gurable In a medium fabric position, using the installation cable or a programmed transmitter, press the UP button until the fabric has reached the desired upper end position (to upper limit stop). The drive system starts, stops brie y and starts again (as long as the UP button is pressed). The drive system automatically stops when reaching the upper limit stop. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Optional: Activation of the relief function for the upper limit stop: refer to section 5.6.2. Press the DOWN button again, until the fabric has reached the desired lower end position. The drive system starts, stops brie y and starts again (as long as the button is pressed). Corrections can be made with the buttons and
. Keep the UP button pressed until the drive sys-
tem stops automatically. End position setting of option B is completed. Fig. 10 End position setting option B:
Option C: Fixed upper and lower end position In a medium fabric position, using the installation cable or a programmed transmitter, press the UP button until the fabric has reached the desired upper end position (to upper limit stop). The drive system starts, stops brie y and starts again (as long as the UP button is pressed). The drive system automatically stops when reaching the upper limit stop. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Optional: Activation of the relief function for the upper limit stop: refer to section 5.6.2. Press the DOWN button again, until the fabric has reached the lower end position (to bottom limit stop). The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). The drive system automatically stops when reaching the lower limit stop. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option C is completed. Fig. 11 End position setting option C:
5.6.10 Option D: Upper end position freely con gu-
rable, xed lower end position Option D: Upper end position freely con gurable, xed lower end position In a medium fabric position, using the installation cable or a programmed transmitter, press the UP button until the fabric has reached the desired upper end position. The drive system starts, stops brie y and starts again (as long as the button is pressed). Corrections can be made with the buttons and
. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Press the DOWN button again, until the fabric has reached the lower end position (to bottom limit stop). The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). The drive system automatically stops when reaching the lower limit stop. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option D is completed. Fig. 12 End position setting option D:
8 | US+CA elero GmbH Transmitter programming | Troubleshooting 5.7 Transmitter programming Important Requirement: The drive system must be in wireless opera-
tion. If the end positions are not programmed, the fabric is loosened from the winding shaft. Programming the ( rst) transmitter Instruction 1 Disconnecting and recon-
necting the power supply 2 On the transmitter to be programmed, press the programming button P for approx. 1 second. 3 Immediately (max. 1 se-
cond) after start of the up movement, press the UP button . 4 Immediately (max. 1 se-
cond) after start of the down movement, press the DOWN button . Result For approx. 5 minutes, the drive system is in programming mode. The status indicator ashes. Now (for approx. 2 minutes), the drive system is in programming mode
(up and down move-
ment). The status indicator ashes brie y. The fabric stops brie y, moves on, stops and moves downwards. The status indicator ashes brie y. The drive system stops. The ( rst) transmitter is programmed. 5.8 Programming additional transmitters(s) A maximum of 16 transmitters can be programmed. Programming additional transmitters(s) Instruction 1 For three seconds, on a already programmed trans-
mitter press simultaneously for 3 seconds the UPbutton , the DOWNbutton and the programming button P.
(alternative to above line) Disconnecting and recon-
necting the power supply 2 On the (additional) transmitter to be program-
med, press the program-
ming button P. 4 On the (additional) transmitter to be program-
med, immediately (max. 1 second) after start of the up movement, press the UP button . 5 On the (additionally) transmitter to be program-
med, immediately (max. 1 second) after start of a down movement, press the DOWNbutton . Result The status indicator ashes. The drive sys-
tem is in programming mode (up and down movement). For approx. 5 minutes, the drive system is in programming mode. The status indicator ashes brie y. The drive system is (for approx. 2 minutes) in programming mode
(up and down move-
ment). The status indicator ashes brie y. The fabric stops brie y, moves on, stops and moves downwards. The status indicator ashes brie y. The drive system stops. Stopping the bidirectional wireless programming mode:
Press the STOP button for at least 6 seconds until the sta-
tus indicator is blinking (transmitter-dependent). Important Complete, uninterrupted up and down movement is neces-
sary to adapt the fabric protection system to the fabric. 5.9 Technical data The separately available technical data sheet will provide you with an overview of the most important technical para-
meters. Troubleshooting 6 Problem /
malfunction Drive system stops during movement Remedy, correction Set end posi-
tions Possible cause End positions not correctly set Drive system is in setting mode Drive system stops after a short period of time End positions have been saved Stiff fabric Drive system only runs in one direction Drive system does not react Program-
ming of end positions not possible Connection error No power supply Temperature limiter has triggered Random drive movements The distance to the end position or to the limit stop is too short Set second end position Check smooth running of the fabric Check connec-
tion Check power supply Have the drive system cool down Delete end positions Reset end positions The drive sys-
tem must run, stop brie y and start again
(as long as a button on the elero installa-
tion cable or a programmed transmitter is pressed). Fig. 13 RolTop-915 troubleshooting 7 8 Servicing The RolTop-915 is maintenance-free. Cleaning WARNING Risk of injury due to electricity. Risk of electric shock. Risk due to potential live parts. Only carry out cleaning when the system is disconnected from the voltage. To do so, disconnect the drive cable. Clean the product surface only with a soft, clean and dry Programming of the additional transmitter is complete. cloth. elero GmbH US+CA | 9 Declaration of Conformity | UL approval | Homologation UL 13 US: Addendum to the manual UL approval This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following thwo conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference recieved, inclu-
ding interference that may cause undesired operation. Any changes or modi cations made to this device without the express permission of the manufacturer may void the users authority to operate this device. 14 CA: Addendum au manuel Homologation UL Le prsent appareil est conforme aux CNR-210 (et FCC part 15) dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 9 Repair In case of questions, please contact your local specialist. Please always provide the following information:
Article number and designation on name plate Type of defect Previous and unusual occurrences Circumstances Own assumption 10 Address elero GmbH Antriebstechnik Linsenhofer Str. 65 72660 Beuren Germany Phone: +49 7025 13-01 Fax:
+49 7025 13-212 info@elero.de www.elero.com If you require a contact outside of Germany, please visit our website. 11 Disposal / scrapping After unpacking the system, dispose of the packaging mate-
rial according to applicable regulations. After the last use, dispose of the product according to appli-
cable regulations. Scrapping When scrapping the product, applicable international, natio-
nal and local rules and regulations must be complied with. Please observe the recycling and dismantling properties of materials and components as well as environmental and health risks during recycling and disposal. Material groups like different plastics and metals must be sorted and put into the recycling system or disposed of. Disposal of electrotechnical and electrical components Disposal and recycling of electrotechnical and electrical components must be carried out according to the applicable laws or national regulations. 12 EC Declaration of Conformity EG-KONFORMITTSERKLRUNG Wir erklren hiermit, dass das/die nachfolgend genannte/n Produkt/e der Maschinenrichtlinie 2006/42/EG entspricht/entsprechen. Produktbezeichnung:
Rohrmotor RolTop S-915 (120V/60Hz) alle Varianten RolTop M-915 (120V/60Hz) alle Varianten Beschreibung:
Einsteckantrieb fr Rolllden mit 915 MHz Funkempfnger Die bereinstimmung der/s bezeichneten Produkte/s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen bercksichtigt:
R&TTE-Richtlinie 1999/5/EG Niederspannungsrichtlinie 2006/95/EG DIN EN 60335-2-97 (VDE 0700-97):2009 DIN EN 14 202:2004 Beuren, 31.05.2012 Ralph Trost
-CE-Beauftragter-, -Doku-Bevollmchtigter-
Fig. 14 EC Declaration of Conformity RolTop-915 type S and M elero GmbH Antriebstechnik Linsenhofer Strae 65 D-72660 Beuren Phone: +49 7025 13-01 Fax: +49 7025 13-212 info@elero.de www.elero.com Technical modifications reserved
1 | SunTop 1 | Users Manual | 1.88 MiB | September 08 2013 |
Roller shutter drive SunTop 120V / 60 Hz Table of contents 5.7 Technical data 1 2 2.1 2.2 2.3 Operating and installation instructions General information Standards and guidelines Intended use Foreseeable misuse 2.4 Warranty and liability 2.5 Customer service of the manufacturer 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 5 5.1 5.2 5.3 5.4 5.5 5.6 Safety General safety instructions Layout of safety instructions General safety principles General obligations of the operator General requirements on personnel Safety instructions on technical condition Safety instructions on transport, assembly and installation Safety instructions on operation Safety instructions on electrical installation Product description Installation Mechanical mounting Electrical connection Connection example, SunTop 120 V / 60 Hz Parallel connection Commissioning End position and relief settings 5.6.1 Relief function for end position(s) 5.6.2 Relief function at the upper stop 5.6.3 Relief function at the lower stop 5.6.4 Changing / deleting of end positions and deleting the relief function 5.6.5 Four options for end position settings 5.6.6 Option A: Upper and lower end position freely con gurable 7 5.6.7 Option B: Fixed upper end position, lower end position freely con gurable 5.6.8 Option C:
Fixed upper and lower end position 5.6.9 Option D:
Upper end position freely con gurable, xed lower end position 1 1 1 2 2 2 2 2 2 2 3 3 3 3 4 4 4 4 4 5 5 6 6 6 6 6 6 6 6 7 7 7 8 6 7 8 9 10 11 12 13 14 Troubleshooting Servicing Cleaning Repair Address Disposal / scrapping EC Declaration of Conformity US: Addendum to the manual UL approval CA: Addendum au manuel Homologation UL 8 8 8 8 8 8 8 9 9 9 Roller shutter drive SunTop 120 V / 60 Hz 1 Operating and installation instructions 2 Please keep these operating instructions for later use and have them available during the complete service life of the product!
The German version of these operating instructions is the original version. All foreign language documents are translations of the original version. All rights reserved with regard to patent claim or submission of design or utility patent. General information The structure of these operating instructions is based on the service life phases of the electrical drive (subsequently referred to as product). The manufacturer reserves the right to make changes to the technical data included in these operating instructions. The-
se may deviate from the respective model of the product while the factual information are generally not changed and are not losing their validity. The current state-of-the-art can be obtained from the manufacturer at all times. Potential claims cannot be asserted. Deviations from text and pictori-
al statements are not possible and depending on the tech-
nical development, setup and accessories of the product. Deviating information on special models are included by the manufacturer in the sales documentation. Other information shall remain unaffected by this. 2.1 Standards and guidelines During system design, basic safety and health requirements of applicable laws, standards and guidelines were obser-
ved. The safety is con rmed by means of the Declaration of Conformity (refer to EC Declaration of Conformity). All safety information in these operating instructions are based on currently applicable laws and regulations in Germany. All information in the operating instructions must be obser-
138186701_US+CA_0513 Intended use | Safety 2.2 ved at all times. Apart from the safety instructions in these operating instructions, applicable local regulations on pre-
vention of accidents, environmental protection and occupa-
tional safety must be observed. Regulations and standards for safety assessment can be found in the EC Declaration of Conformity. Intended use This product is intended for use in facade construction for driving electrical sun protection devices. Decisive for the determination of the drive system is the elero drive computation program (http://elero.com/
en;service;drive-computation-program.htm). Other applications must be approved in advance by the ma-
nufacturer elero GmbH Antriebstechnik (refer to Address). The operator alone is liable for all damage due to improper use of the product. The manufacturer does not assume any liability for personal injuries and property damage due to misuse or procedural violations by improper use or commis-
sioning. The product may only be operated by trained and autho-
rized personnel under observation of all safety instructions. Safe and correct operation and operational safety of the product is subject to operation according to its intended use according to the provisions of these operating and installati-
on instructions. The intended use includes observance and compliance of all safety instructions included in these operating instruc-
tions and all applicable regulations by the trade association and applicable laws for environmental protection. The inten-
ded use also includes compliance of all company regulati-
ons included in these operating and installation instructions. 2.3 Foreseeable misuse Foreseeable misuse includes operating the product not in accordance with the intended use approved by the manu-
facturer elero GmbH Antriebstechnik (refer to Address). 2.4 Warranty and liability Generally, the general terms and conditions of sale and delivery of the manufacturer elero GmbH Antriebstechnik
(refer to Address) apply. The terms and conditions of sale and delivery are part of the sales documentation and are handed over to the operator on delivery. Liability claims for personal and property damage are excluded if such dama-
ge is due to one or several of the following causes:
Opening the product by the customer Improper use of the product Incorrect installation, commissioning or operation of the product Structural changes to the product without the written approval of the manufacturer Operating the product with incorrectly installed connec-
tions, defective safety equipment or with not properly installed safety and protective equipment Failure to observe the safety regulations and instructions included in these operating instructions Safety 3 3.1 General safety instructions These operation and installation instructions include all safety instructions for prevention and avoiding of dangers during handling of the product over its entire life cycles. Compliance with all speci ed safety instructions ensures safe operation of the product. 3.2 Layout of safety instructions The safety instructions in this document are marked by dan-
ger signs and safety symbols and are designed according to the SAFE principle. They include information on type and source of the danger as well as on possible consequences and on prevention of the danger. The following table de nes the design and description of the levels of danger with potential physical injuries as they are used in these operating instructions. Symbol Signal word DANGER Description Warns of a potential ac-
cident with if instructions are not complied with leading to life-threatening, irreversible injuries or death. WARNING Warns of a potential ac-
cident with if instructions are not complied with lea-
ding to severe, potentially life-threatening, irreversib-
le injuries or death. CAUTION Warns of a potential ac-
cident with if instructions are not complied with leading to light, reversible injuries. Fig. 1 Notation of personal injury The following table describes symbols used in these ope-
rating instructions for illustration of dangerous situations in connection with the respective symbol for the level of danger. Symbol Description Danger due to voltage, electrical shock:
This symbol indicates dangers due to electricity. Fig. 2 Notation of a speci c danger The following table de nes the illustration and description of situations in these operating instructions that may lead to damage to the product or indicates facts, conditions, tips and information. Non-compliance with the speci ed technical data 2.5 Customer service of the manufacturer In case of a defect, the product may only be repaired by the manufacturer. Please refer to section Address for the return address of the customer service. If you did not acquire the product directly from elero, please contact your supplier. 2 | US+CA elero GmbH Description 3.4 General obligations of the operator Safety Symbol Signal word NOTE IMPOR-
TANT This symbol warns of po-
tential property damage. This symbol indicates important facts and con-
ditions as well as further information in these operating and installation instructions. Additionally, it refers to certain inst-
ructions giving additional information or helping you to perform a task. Fig. 3 Notation of property damage and additional informa-
tion The following example illustrates the general layout of a safety instruction:
SIGNAL WORD Type and source of danger Description of the type and source of danger Measures for prevention of the danger. 3.3 General safety principles The product was designed according to the state-of-the-art and recognized safety-related rules and is safe for opera-
tion. During product design, basic safety and health requi-
rements of applicable laws, standards and guidelines were observed. The safety of the product is con rmed by the EC Declaration of Conformity. All information on safety refer to currently applicable direc-
tives of the European Union. Operators in other countries must ensure that applicable local laws and regulations are observed. Apart from the safety instructions in these operating inst-
ructions, generally applicable regulations on prevention of accidents and environmental protection must be observed. The product must only be used in technically awless condi-
tion and for proper safety-conscious and risk-conscious use while observing the operating instructions. The product is designed for operation according to section intended use. Operation of the product not according to its intended use may lead to danger for life and limb of the user and third parties or cause damage to the machine and other proper-
ties. The manufacturer must be immediately and directly in-
formed on accidents or near misses during operation of the product that caused or may have caused personal injuries and or damage to the working environment. All safety instructions in the operating instructions and on the product must be observed. Additionally to observing these safety instructions, the operator must ensure that all national and international regulations applicable in the country of operation and other binding regulations on ope-
rational safety, prevention of accidents and environmental protection are complied with. All work on the product must only performed by trained, safety-related instructed and authorized personnel. Appropriately quali ed personnel must observe all appli-
cable standards and regulations in the country of installation and inform the customer on the operating and maintenance requirements of the product. The operator is obliged to only operate the product in technically awless and operationally safe condition. The operator must ensure that apart from the safety instruc-
tions in the operating instructions, generally applicable regulations on safety and prevention of accidents, the provisions of DIN VDE 0100 as well as the regulations on environmental protection of the respective country of operation are observed and complied with. The operator is obliged to ensure that all work on the pro-
duct is carried out by trained and safety-related instructed and authorized personnel. Ultimately responsible for accident-free operation is the operator of the product or the personnel authorized by him. The operator is responsible for compliance of the tech-
nical speci cations particularly the statistic and dynamic load limits. Non-compliance with static load limits may lead to loss of the supporting or holding function. With respect to the intended use, the operator must ensu-
re dry, not too warm ambient conditions (building condi-
tions) under the in uence of radial heat. Deviations must be approved by the manufacturer. 3.5 General requirements on personnel Each person commissioned to work with the product must have read and understood the entire operating instructions prior to carrying out the respective work. This does also apply if the person has already worked with this kind of product or was trained on it. Before start of all work, the personnel has to be made aware of all dangers in connection with working on the product. All personnel commissioned to work with the product must have no physical limitations temporarily or perma-
nently in uencing their attention or good judgment (e. g. by fatigue). Handling the product or any assembly, disassembly and cleaning by minors or under the in uence of alcohol, drugs or medication is not permitted. Personnel must wear appropriate personal protective equipment according to the work to be carried out and the present work environment. Children must not play with xed control panels. Keep remote controls away from children. Observe moving roller shutters and keep persons on a distance until the shutter has properly closed. Do not operate the sun blind(s) if work like window cleaning is carried out near by. 3.6 Safety instructions on technical condition Prior to installation the product must be checked for damage and proper condition. The operator is obliged to only operate the product in technically awless and operationally safe condition. The technical condition must comply with statutory require-
ments applicable at the date of manufacturing stated on the name plate. If dangers for personnel or changes in the operational behavior are identi ed, the product must be put out of operation immediately and the operator must be informed on the incident. elero GmbH US+CA | 3 Product description | Installation Without approval by the manufacturer, no modi cation, extensions or alterations must be carried out on the product. The system must be regularly checked for imbalance or signs of wear or damaged cables and springs (if appli-
cable). 3.7 Safety instructions on transport, assembly and installation In general, the respective transport company is responsible for transporting the product. The following safety require-
ments must be observed during transport, assembly and installation of the product:
During transport, the product must be secured according to the regulations of the used means of transport. For transport, only hoisting equipment and suspension gear must be used that are appropriately dimensioned for safely handling the forces occurring during loading, unloading and assembly of the product. Only points de ned for hoisting or suspension at the pallet and the product must be used for hoisting or sus-
pension. If work must be carried out under suspended parts or working equipment, these must be secured against falling by suitable means. It must be ensured by suitable hois-
ting equipment that loads drift unintentionally, fall or get unhooked unsupervised. Standing under suspended loads is forbidden. During loading with hoisting equipment, a safety helmet must be worn. Assembly and installation must generally only be carried out by trained and suitably instructed specialists. The rated torque and the rated operating time must be suitable for the properties of the driven component (fa-
bric). The smallest internal tube diameter for the winding shaft is 47 mm for SunTop type M and 58 mm for SunTop type L. Access to the drive system must be ensured by a freely accessible appropriately sized inspection ap that can easily be opened. 3.8 Safety instructions on operation Before initial commissioning, the operator is obliged to inspect the product for safe and proper operation. Inspections must also be carried out during operation of the product in regular intervals de ned by the operator. 3.9 Safety instructions on electrical installation Work on the electric system of the used equipment must only be carried out by authorized electricians according to applicable rules and regulations by the trade association, particularly the provisions of DIN VDE 0100. Additionally, the national legal regulations of the respective country of operation must be observed. In case of defects like loose connections or defective or damaged cables on the system, the product must not put into operation. Prior to any inspection, installation or disassembly work, the system (blinds, shutter) must be disconnected from the voltage. All electrical connections, safety equipment, safeguards etc. must be properly installed, connected and grounded. The power connection must be designed according to the information in the electrical circuit diagram (type and level of voltage). One circuit breaker is suf cient to disconnect the system from the mains supply (if only one phase and neutral is used). If one xed (stationary installed) drive system is not equipped with a mains cable with plug or other means of disconnection from the mains supply with a contact opening width according to the provisions of overvoltage category II (according to IEC 60664-1) for full disconnect, an isolating device of this kind must be installed into the xed electrical installation according to the installation regulations. Mains connection cables for drive systems with rubber hose cables (code 60245 IEC 53) must always be repla-
ced by cables of the same type. The following applies for drive systems with access to unprotected, movable parts after installation: Movable parts of the drive system must be installed at least 2.5 m above the ground (or another level providing access to the drive system). 4 Product description The SunTop is a electromechanical tubular motor drive. During operation it carries out radial movements. Commissioning of the SunTop with elero installation cable for setting of various functions. Fabric protection system with retraction Fabric relief function (fabric protection system) The values for your SunTop model can be found on the name plate. Depending on torque and size, the different models of the SunTop are equipped with different types of braking systems. This may lead to different operating properties e. g. when approaching end positions. 5 Installation CAUTION Risk of injury due to hot surfaces. The drive system gets hot during operation, therefore the housing may be hot. Risk of skin burns. Wear personal protective equipment (protective gloves). Due to potential material defects, a broken gear unit, drive or coupling defect may cause injuries from impacts or shocks. For design of the system, suitable materials were used and a sampling test in form of a double load test accor-
ding to DIN EN 60335-2-97 was carried out. Risk of injury from impacts or shocks due to incorrectly installed or not properly engaged motor bearings. Risk due to insufficient stability and stored energy (gravity). Selection of motor bearings according to torque speci -
cations. The drive system must be secured with all provided safety equipment. Inspection for proper engagement on the motor bearing and correct screw tightening torques. 4 | US+CA elero GmbH Mechanical mounting | Electrical connection WARNING Risk of injury due to electricity. Risk of electric shock. Electrical work must only be carried out by authorized electricians. Risk of injury due to electricity. Potential risk from parts that have become live due to a malfunction. The electrical connection including wiring is described in the operating and installation instructions. CAUTION Risk of injury due to malfunctions due to incorrect installa-
tion. Excessive winding of the drive system leads to possible destruction of system parts. For safe operation, end positions must be set / program-
med. Training courses by the manufacturer for specialized companies. NOTE Power supply failure, braking of machine components and other defects. For safe operation, the system must be properly installed and the end positions must be set on commissioning. Damage to the SunTop by humidity ingress. On protection class IP44 systems, all cables or plugs must be protected against ingress of humidity. This action must be taken immediately after removing the SunTop from its original packaging. The drive system must be installed in a position safe from rain. Important On delivery (factory settings), the SunTop is in commissio-
ning mode. It is necessary to set the end positions
(refer to section 5.6). 5.1 Mechanical mounting Important preliminary consideration:
The working space around the installed drive system is often limited. Therefore, get an overview of the implementa-
tion of the electrical connection (refer to section 5.2) prior to the mechanical installation and carry out respective chan-
ges, if necessary. CAUTION Risk of injury by squeezing. Horizontal clearance of at least 0.40 m between the com-
pletely unrolled part (bottom rail) and any other stationary component must be observed. NOTE Damage to electrical lines by pressure or tensile loads. All electrical lines must be laid safe from pressure or tensile loads. Observe the bending radius of the cables (at least 50 mm). Lay connection cables in a loop downwards to prevent water from running into the system. Damage to the drive system by impact loads. Always slide the drive system onto the shaft. Never ham-
mer onto the shaft or the drive system!
Never drop the drive system!
Damage to or destruction of the drive system by drilling. Never drill into the drive system!
Important Attach the SunTop only to the provided mounting elements. Firmly mounted control units must be visible attached. The fabric (awning fabric) must be mounted on the win-
ding shaft. The pro le tube must have suf cient clearance to the motor tube. Make sure there is suf cient axial play (1 - 2 mm). Installation in pro le tubes Push the drive with suitable adapter and driving collar into the profile tube. Protect the motor cable in order to avoid damage from the driven com-
ponent. A B Secure the counterbearings to pre-
vent axial movement, e. g. screw or rivet on shaft carrier. Axially secure the drive in the bea-
ring!
Attach the fabric to the shaft!
5.2 Electrical connection C WARNING Danger to life due to incorrect electrical connection. Risk of electric shock. Before initial commissioning, check the correct connec-
tion of the PE conductor. NOTE Damage to the SunTop due to incorrect electrical connec-
tion. Before initial commissioning, check the correct connec-
tion of the PE conductor. Damage to or destruction of the SunTop due to ingress of humidity. For devices with protection class IP44, the customer-
provided connection of cables or plugs (wiring) must also be compliant with protection class IP44. Damage to or destruction of the SunTop for models with 120 V 1 AC due to incorrect control. Switches that are preset to OFF (dead man) for drive sys-
tems must be mounted in viewing range of the SunTop but away from moving parts and at a height above 1.5 m. Important For electrical connection, generally no connection and dis-
connection of the connection cable or plug is necessary. Only connect when the system is disconnected from the voltage. To do so, disconnect the drive cable. 1 Use a suitable screwdriver to push the locking mecha-
nism of the device plug to the cable. 2 Disconnect the plug. 3 Insert the device plug until the locking mechanism enga-
ges. elero GmbH US+CA | 5 Installation: Electrical connection | End position settings Removing and inserting the device plug Delivery con-
dition Remove plug Insert plug 2 1 3 Fig. 4 Removing and inserting the device plug 5.3 Connection example, SunTop 120 V / 60 Hz 1 2 3 4 1 Winding thermostat 2 Device switch 3 Junction box 4 Switch box 5 Shutter switch /
Shutter button 6 Electronic 7 Condenser sw br bl gr/ge black brown blue green / yellow w s r b l b e g
r g 7 6 5 1 0 2 L1 N PE 3 2 1 3 2 1 Fig. 5 Circuit diagram SunTop 120 V / 60 Hz and Wiring when using a Hirschmann plug connection STAS-3 Important The motor controls in up and down direction must be inter-
locked. 5.4 Parallel connection Important You can connect several SunTop systems in parallel. To do so, please observe the maximum control capacity. 5.5 Commissioning Important On delivery, the drive system is set to commissioning mode. It is necessary to set the end positions with the elero installation cable. Connecting the installation cable is only for commissio-
ning of the drive system and for con guration. Switch on power supply. Now, you can set the end positions with the elero instal-
lation cable. 5.6 End position and relief settings Important preliminary consideration:
Before carrying out the end position settings, decide on a certain relief function (different combinations available according to the following models). This will save you unnecessary time and effort during con-
guration!
Press one of the drive buttons until the drive system indica-
tes switchover to setting mode with a short automatic stop. Now, you can set the end positions. After setting both end positions, the setting mode is closed. 5.6.1 Relief function for end position(s) If one end position was programmed to limit stop, an additi-
onal relief function can be activated for the fabric. Important Activation of the relief function (for options B to D) is carried out in one step with programming of the end positions (refer to sections 5.6.7 to 5.6.9)!
5.6.2 Relief function at the upper stop For option B (refer to section 5.6.7) and option C (refer to section 5.6.8):
Activating the relief function at the upper limit stop 1 Using the installation cable, keep the UP button pressed from step (section 5.6.7 and 5.6.8) and press additionally (simultaneously) the DOWNbutton
. Keep both buttons pressed until the fabric stops. The relief function at the upper limit stop is activated. 5.6.3 Relief function at the lower stop For option C (refer to section 5.6.8) and option D (refer to section 5.6.9):
Activating the relief function at the lower limit stop 1 Using the installation cable, keep the DOWN button pressed from step (section 5.6.8 and 5.6.9) and press additionally (simultaneously) the UPbutton
.Keep both buttons pressed until the fabric stops. The relief function at the lower limit stop is activated. 5.6.4 Changing / deleting of end positions and deleting the relief function It is not possible to change or delete one individual end position. This is always carried out in pairs (upper and lower end position at once). By deleting the end positions, also the setting of the optio-
nal relief function is lost. ele r o Blue (neutral wire) (1) Black (2) Brown (3) Green-yellow (4) Blau (Neutralleiter) (1) Schwarz (2) Braun (3) Grn-gelb Fig. 6 Installation cable connection 6 | US+CA elero GmbH Relief function | End position settings Important Complete, uninterrupted up and down movement is neces-
sary to adapt the fabric protection system to the fabric. 5.6.7 Option B: Fixed upper end position, lower end position freely con gurable Changing / deleting of end positions 1 In a medium fabric position, using the installation cable, simultaneously press both direction buttons (
and ) and keep them pressed until the drive system brie y moves up and down. Deleting the end position settings is completed. The end positions can be reset. 5.6.5 Four options for end position settings Four different combinations of end position settings are available and can be selected. End position settings (4 options) A Upper and lower end position freely con gurable B Fixed upper end position, lower end position freely con gurable C Fixed upper and lower end position D Upper end position freely con gurable, xed lower end position Fig. 7 Options of end position settings for SunTop 5.6.6 Option A: Upper and lower end position freely con gurable Option A:
Upper and lower end position freely con gurable In a medium fabric position, using the installation cable, press the UP button until the fabric has reached the desired upper end position. The drive system starts, stops brie y and starts again (as long as the UP button is pressed). Corrections can be made with the buttons and
. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Press the DOWN button again, until the fabric has reached the desired lower end position. The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). Corrections can be made with the buttons and
. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. End position setting of option A is completed. Fig. 8 End position setting option A:
Option B: Fixed upper end position, lower end position freely con gurable In a medium fabric position, using the installation cable, press the UP button until the fabric has reached the desired upper end position (to upper limit stop). The drive system starts, stops brie y and starts again (as long as the UP button is pressed). The drive system automatically stops when reaching the upper limit stop. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Optional: Activation of the relief function for the upper limit stop: refer to section 5.6.2. Press the DOWN button again, until the fabric has reached the desired lower end position. The drive system starts, stops brie y and starts again (as long as the button is pressed). Corrections can be made with the buttons and
. Keep the UP button pressed until the drive sys-
tem stops automatically. End position setting of option B is completed. Fig. 9 End position setting option B:
5.6.8 Option C:
Fixed upper and lower end position Option C: Fixed upper and lower end position In a medium fabric position, using the installation cable, press the UP button until the fabric has reached the desired upper end position (to upper limit stop). The drive system starts, stops brie y and starts again (as long as the UP button is pressed). The drive system automatically stops when reaching the upper limit stop. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Optional: Activation of the relief function for the upper limit stop: refer to section 5.6.2. Press the DOWN button again, until the fabric has reached the lower end position (to bottom limit stop). The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). The drive system automatically stops when reaching the lower limit stop. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option C is completed. Fig. 10 End position setting option C:
elero GmbH US+CA | 7 End position settings | Troubleshooting | Repair 5.6.9 Option D:
Upper end position freely con gurable, xed lower end position Option D: Upper end position freely con gurable, xed lower end position In a medium fabric position, using the installation cable, press the UP button until the fabric has reached the desired upper end position. The drive system starts, stops brie y and starts again (as long as the button is pressed). Corrections can be made with the buttons and
. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Press the DOWN button again, until the fabric has reached the lower end position (to bottom limit stop). The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). The drive system automatically stops when reaching the lower limit stop. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option D is completed. Fig. 11 End position setting option D:
5.7 Technical data The separately available technical data sheet will provide you with an overview of the most important technical para-
meters. Troubleshooting 6 Problem /
malfunction Drive system stops during movement Remedy, correction Set end posi-
tions Possible cause End positions not correctly set Drive system is in setting mode Drive system stops after a short period of time End positions have been saved Stiff fabric Connection error Drive system only runs in one direction Drive system does not react Set second end position Check smooth running of the fabric Check connec-
tion No power supply Temperature limiter has triggered Check power supply Have the drive system cool down Problem /
malfunction Program-
ming of end positions not possible Possible cause Random drive movements The distance to the end position or to the limit stop is too short Remedy, correction Delete end positions Reset end positions The drive sys-
tem must run, stop brie y and start again
(as long as a button on the installa-
tion cable is pressed). Fig. 12 SunTop troubleshooting 7 8 Servicing The SunTop is maintenance-free. Cleaning WARNING Risk of injury due to electricity. Risk of electric shock. Risk due to potential live parts. Only carry out cleaning when the system is disconnected from the voltage. To do so, disconnect the drive cable. Clean the product surface only with a soft, clean and dry cloth. Repair 9 In case of questions, please contact your local specialist. Please always provide the following information:
Article number and designation on name plate Type of defect Previous and unusual occurrences Circumstances Own assumption 10 Address elero GmbH Antriebstechnik Linsenhofer Str. 65 72660 Beuren Germany Phone: +49 7025 13-01 Fax:
+49 7025 13-212 info@elero.de www.elero.com If you require a contact outside of Germany, please visit our website. 11 Disposal / scrapping After unpacking the system, dispose of the packaging mate-
rial according to applicable regulations. After the last use, dispose of the product according to appli-
cable regulations. Scrapping When scrapping the product, applicable international, natio-
nal and local rules and regulations must be complied with. 8 | US+CA elero GmbH EC Declaration of Conformity | UL approval | Homologation UL Please observe the recycling and dismantling properties of materials and components as well as environmental and health risks during recycling and disposal. Material groups like different plastics and metals must be sorted and put into the recycling system or disposed of. Disposal of electrotechnical and electrical components Disposal and recycling of electrotechnical and electrical components must be carried out according to the applicable laws or national regulations. 12 EC Declaration of Conformity EG-KONFORMITTSERKLRUNG Wir erklren hiermit, dass das/die nachfolgend genannte/n Produkte der Maschinenrichtlinie 2006/42/EG entspricht/entsprechen. Produktbezeichnung: Rohrmotor SunTop M (120V/60Hz) alle Varianten Beschreibung:
Einsteckantrieb fr Markisen Die bereinstimmung der/s bezeichneten Produkte/s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen bercksichtigt:
EMV-Richtlinie 2004/108/EG Niederspannungsrichtlinie 2006/95/EG DIN EN 14 202:2004 DIN EN 60335-2-97 (VDE 0700-97):2010 Beuren, 30.05.2012 Ralph Trost
-CE-Beauftragter-, -Doku-Bevollmchtigter-
Fig. 13 EC Declaration of Conformity SunTop type M 13 US: Addendum to the manual UL approval This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following thwo conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference recieved, inclu-
ding interference that may cause undesired operation. Any changes or modi cations made to this device without the express permission of the manufacturer may void the users authority to operate this device. 14 CA: Addendum au manuel Homologation UL Le prsent appareil est conforme aux CNR-210 (et FCC part 15) dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. elero GmbH US+CA | 9 elero GmbH Antriebstechnik Linsenhofer Strae 65 D-72660 Beuren Phone: +49 7025 13-01 Fax: +49 7025 13-212 info@elero.de www.elero.com Technical modifications reserved
1 | SunTop 2 | Users Manual | 1.54 MiB | September 08 2013 |
Roller shutter drive SunTop-915 120 V / 60 Hz Table of contents 1 2 2.1 2.2 2.3 Operating and installation instructions General information Standards and guidelines Intended use Foreseeable misuse 2.4 Warranty and liability 2.5 Customer service of the manufacturer 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 5 5.1 5.2 5.3 5.4 5.5 Safety General safety instructions Layout of safety instructions General safety principles General obligations of the operator General requirements on personnel Safety instructions on technical condition Safety instructions on transport, assembly and installation Safety instructions on operation Safety instructions on electrical installation Product description Installation Mechanical mounting Electrical connection Connection example SunTop-915 120 V / 60 Hz Parallel connection Commissioning 5.5.1 Installation cable connection 5.5.2 Wireless connection (transmitter operation) 5.6 End position and relief settings 5.6.1 Relief function for end position(s) 5.6.2 Relief function at the upper stop 5.6.3 Relief function at the lower stop 5.6.4 Changing / deleting of end positions and deleting the relief function 5.6.5 Programming or deleting additional fabric positions 5.6.6 Four options for end position settings 5.6.7 Option A: Upper and lower end position freely con gurable 5.6.8 Option B: Fixed upper end position, 1 1 2 2 2 2 2 2 2 2 3 3 3 4 4 4 4 4 5 5 6 6 6 6 6 6 6 7 7 7 7 7 7 7 lower end position freely con gurable 5.6.9 Option C:
Fixed upper and lower end position 5.6.10 Option D:
Upper end position freely con gurable, xed lower end position 5.7 5.8 5.9 6 7 8 9 10 11 12 13 14 Transmitter programming Programming additional transmitters(s) Technical data Troubleshooting Servicing Cleaning Repair Address Disposal / scrapping EC Declaration of Conformity US: Addendum to the manual UL approval CA: Addendum au manuel Homologation UL 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 Roller shutter drive SunTop-915 120V / 60Hz 1 Operating and installation instructions 2 Please keep these operating instructions for later use and have them available during the complete service life of the product!
The German version of these operating instructions is the original version. All foreign language documents are translations of the original version. All rights reserved with regard to patent claim or submission of design or utility patent. General information The structure of these operating instructions is based on the service life phases of the electrical drive (subsequently referred to as product). The manufacturer reserves the right to make changes to the technical data included in these operating instructions. The-
se may deviate from the respective model of the product while the factual information are generally not changed and are not losing their validity. The current state-of-the-art can be obtained from the manufacturer at all times. Potential claims cannot be asserted. Deviations from text and pictori-
al statements are not possible and depending on the tech-
nical development, setup and accessories of the product. Deviating information on special models are included by the manufacturer in the sales documentation. Other information shall remain unaffected by this. 138186806_US+CA_0513 Standards and guidelines | Safety 2.1 Standards and guidelines 2.2 During system design, basic safety and health requirements of applicable laws, standards and guidelines were obser-
ved. The safety is con rmed by means of the Declaration of Conformity (refer to EC Declaration of Conformity). All safety information in these operating instructions are based on currently applicable laws and regulations in Germany. All information in the operating instructions must be obser-
ved at all times. Apart from the safety instructions in these operating instructions, applicable local regulations on pre-
vention of accidents, environmental protection and occupa-
tional safety must be observed. Regulations and standards for safety assessment can be found in the EC Declaration of Conformity. Intended use This product is intended for use in facade construction for driving electrical sun protection devices. Decisive for the determination of the drive system is the elero drive computation program (http://elero.com/
en;service;drive-computation-program.htm). Other applications must be approved in advance by the ma-
nufacturer elero GmbH Antriebstechnik (refer to Address). The operator alone is liable for all damage due to improper use of the product. The manufacturer does not assume any liability for personal injuries and property damage due to misuse or procedural violations by improper use or commis-
sioning. The product may only be operated by trained and autho-
rized personnel under observation of all safety instructions. Safe and correct operation and operational safety of the product is subject to operation according to its intended use according to the provisions of these operating and installati-
on instructions. The receiver must only be connected with equipment and systems approved by the manufacturer. The operator is not protected against interference by other wireless systems and terminal equipment (e. g. also by means of wireless systems) that are properly operated within the same fre-
quency range. Wireless systems must not be operated in areas with increased interference factor (e. g. hospitals, airports etc.). Remote control is only allowed for equipment and systems if malfunctions in hand/wall transmitters or receivers do not lead to damage for personnel, animals or property or if this risk is covered by other safety installati-
ons. The intended use includes observance and compliance of all safety instructions included in these operating instruc-
tions and all applicable regulations by the trade association and applicable laws for environmental protection. The inten-
ded use also includes compliance of all company regulati-
ons included in these operating and installation instructions. 2.3 Foreseeable misuse Foreseeable misuse includes operating the product not in accordance with the intended use approved by the manu-
facturer elero GmbH Antriebstechnik (refer to Address). 2.4 Warranty and liability Generally, the general terms and conditions of sale and delivery of the manufacturer elero GmbH Antriebstechnik
(refer to Address) apply. The terms and conditions of sale and delivery are part of the sales documentation and are handed over to the operator on delivery. Liability claims for personal and property damage are excluded if such dama-
ge is due to one or several of the following causes:
Opening the product by the customer 2 | US+CA elero GmbH Improper use of the product Incorrect installation, commissioning or operation of the product Structural changes to the product without the written approval of the manufacturer Operating the product with incorrectly installed connec-
tions, defective safety equipment or with not properly installed safety and protective equipment Failure to observe the safety regulations and instructions included in these operating instructions Non-compliance with the speci ed technical data 2.5 Customer service of the manufacturer In case of a defect, the product may only be repaired by the manufacturer. Please refer to section Address for the return address of the customer service. If you did not acquire the product directly from elero, please contact your supplier. Safety 3 3.1 General safety instructions These operation and installation instructions include all safety instructions for prevention and avoiding of dangers during handling of the product over its entire life cycles. Compliance with all speci ed safety instructions ensures safe operation of the product. 3.2 Layout of safety instructions The safety instructions in this document are marked by dan-
ger signs and safety symbols and are designed according to the SAFE principle. They include information on type and source of the danger as well as on possible consequences and on prevention of the danger. The following table de nes the design and description of the levels of danger with potential physical injuries as they are used in these operating instructions. Symbol Signal word DANGER Description Warns of a potential ac-
cident with if instructions are not complied with leading to life-threatening, irreversible injuries or death. WARNING Warns of a potential ac-
cident with if instructions are not complied with lea-
ding to severe, potentially life-threatening, irreversib-
le injuries or death. CAUTION Warns of a potential ac-
cident with if instructions are not complied with leading to light, reversible injuries. Fig. 1 Notation of personal injury The following table describes symbols used in these ope-
rating instructions for illustration of dangerous situations in connection with the respective symbol for the level of danger. Safety Symbol Description Danger due to voltage, electrical shock:
This symbol indicates dangers due to electricity. Fig. 2 Notation of a speci c danger The following table de nes the illustration and description of situations in these operating instructions that may lead to damage to the product or indicates facts, conditions, tips and information. all national and international regulations applicable in the country of operation and other binding regulations on ope-
rational safety, prevention of accidents and environmental protection are complied with. All work on the product must only performed by trained, safety-related instructed and authorized personnel. Appropriately quali ed personnel must observe all appli-
cable standards and regulations in the country of installation and inform the customer on the operating and maintenance requirements of the product. 3.4 General obligations of the operator Symbol Signal word NOTE IMPOR-
TANT Description This symbol warns of po-
tential property damage. This symbol indicates important facts and con-
ditions as well as further information in these operating and installation instructions. Additionally, it refers to certain inst-
ructions giving additional information or helping you to perform a task. Fig. 3 Notation of property damage and additional infor-
mation The following example illustrates the general layout of a safety instruction:
SIGNAL WORD Type and source of danger Description of the type and source of danger Measures for prevention of the danger. 3.3 General safety principles The product was designed according to the state-of-the-art and recognized safety-related rules and is safe for opera-
tion. During product design, basic safety and health requi-
rements of applicable laws, standards and guidelines were observed. The safety of the product is con rmed by the EC Declaration of Conformity. All information on safety refer to currently applicable direc-
tives of the European Union. Operators in other countries must ensure that applicable local laws and regulations are observed. Apart from the safety instructions in these operating inst-
ructions, generally applicable regulations on prevention of accidents and environmental protection must be observed. The product must only be used in technically awless condi-
tion and for proper safety-conscious and risk-conscious use while observing the operating instructions. The product is designed for operation according to section intended use. Operation of the product not according to its intended use may lead to danger for life and limb of the user and third parties or cause damage to the machine and other proper-
ties. The manufacturer must be immediately and directly in-
formed on accidents or near misses during operation of the product that caused or may have caused personal injuries and or damage to the working environment. All safety instructions in the operating instructions and on the product must be observed. Additionally to observing these safety instructions, the operator must ensure that The operator is obliged to only operate the product in technically awless and operationally safe condition. The operator must ensure that apart from the safety instruc-
tions in the operating instructions, generally applicable regulations on safety and prevention of accidents, the provisions of DIN VDE 0100 as well as the regulations on environmental protection of the respective country of operation are observed and complied with. The operator is obliged to ensure that all work on the pro-
duct is carried out by trained and safety-related instructed and authorized personnel. Ultimately responsible for accident-free operation is the operator of the product or the personnel authorized by him. The operator is responsible for compliance of the tech-
nical speci cations particularly the statistic and dynamic load limits. Non-compliance with static load limits may lead to loss of the supporting or holding function. With respect to the intended use, the operator must ensu-
re dry, not too warm ambient conditions (building condi-
tions) under the in uence of radial heat. Deviations must be approved by the manufacturer. 3.5 General requirements on personnel Each person commissioned to work with the product must have read and understood the entire operating instructions prior to carrying out the respective work. This does also apply if the person has already worked with this kind of product or was trained on it. Before start of all work, the personnel has to be made aware of all dangers in connection with working on the product. All personnel commissioned to work with the product must have no physical limitations temporarily or perma-
nently in uencing their attention or good judgment (e. g. by fatigue). Handling the product or any assembly, disassembly and cleaning by minors or under the in uence of alcohol, drugs or medication is not permitted. Personnel must wear appropriate personal protective equipment according to the work to be carried out and the present work environment. Children must not play with xed control panels. Keep remote controls away from children. Observe moving roller shutters and keep persons on a distance until the shutter has properly closed. Do not operate the sun blind(s) if work like window cleaning is carried out near by. elero GmbH US+CA | 3 Safety | Product description 3.6 Safety instructions on technical condition Prior to installation the product must be checked for damage and proper condition. The operator is obliged to only operate the product in technically awless and operationally safe condition. The technical condition must comply with statutory require-
ments applicable at the date of manufacturing stated on the name plate. If dangers for personnel or changes in the operational behavior are identi ed, the product must be put out of operation immediately and the operator must be informed on the incident. Without approval by the manufacturer, no modi cation, extensions or alterations must be carried out on the product. The system must be regularly checked for imbalance or signs of wear or damaged cables and springs (if appli-
cable). 3.7 Safety instructions on transport, assembly and installation In general, the respective transport company is responsible for transporting the product. The following safety require-
ments must be observed during transport, assembly and installation of the product:
During transport, the product must be secured according to the regulations of the used means of transport. For transport, only hoisting equipment and suspension gear must be used that are appropriately dimensioned for safely handling the forces occurring during loading, unloading and assembly of the product. Only points de ned for hoisting or suspension at the pallet and the product must be used for hoisting or sus-
pension. If work must be carried out under suspended parts or working equipment, these must be secured against falling by suitable means. It must be ensured by suitable hois-
ting equipment that loads drift unintentionally, fall or get unhooked unsupervised. Standing under suspended loads is forbidden. During loading with hoisting equipment, a safety helmet must be worn. Assembly and installation must generally only be carried out by trained and suitably instructed specialists. The rated torque and the rated operating time must be suitable for the properties of the driven component (fa-
bric). Decisive for the determination of the drive system is the drive computation program of the manufacturer. The smallest internal tube diameter for the winding shaft of the SunTop-915 type M is 47 mm. Access to the drive system must be ensured by a freely accessible appropriately sized inspection ap that can easily be opened. 3.8 Safety instructions on operation Before initial commissioning, the operator is obliged to inspect the product for safe and proper operation. Inspections must also be carried out during operation of the product in regular intervals de ned by the operator. 3.9 Safety instructions on electrical installation Work on the electric system of the used equipment must only be carried out by authorized electricians according to applicable rules and regulations by the trade association, particularly the provisions of DIN VDE 0100. Additionally, the national legal regulations of the respective country of operation must be observed. In case of defects like loose connections or defective or damaged cables on the system, the product must not put into operation. Prior to any inspection, installation or disassembly work, the system (blinds, shutter) must be disconnected from the voltage. All electrical connections, safety equipment, safeguards etc. must be properly installed, connected and grounded. The power connection must be designed according to the information in the electrical circuit diagram (type and level of voltage). One circuit breaker is suf cient to disconnect the system from the mains supply (if only one phase and neutral is used). If one xed (stationary installed) drive system is not equipped with a mains cable with plug or other means of disconnection from the mains supply with a contact opening width according to the provisions of overvoltage category II (according to IEC 60664-1) for full disconnect, an isolating device of this kind must be installed into the xed electrical installation according to the installation regulations. Mains connection cables for drive systems with rubber hose cables (code 60245 IEC 53) must always be repla-
ced by cables of the same type. The following applies for drive systems with access to unprotected, movable parts after installation: Movable parts of the drive system must be installed at least 2.5 m above the ground (or another level providing access to the drive system). 4 Product description The SunTop-915 is a wireless-controlled electromechanical tubular motor drive. During operation it carries out radial movements. Commissioning of the SunTop-915 with elero installation cable or transmitter for con guration of various functions. Fabric protection system with retraction Fabric relief function (fabric protection system) Relief function and retraction for fabric protection are only active in wireless operation. The values for your SunTop-915 model can be found on the name plate. Depending on torque and size, the different models of the SunTop-915 are equipped with different types of braking systems. This may lead to different operating properties e. g. when approaching an end position. 4 | US+CA elero GmbH Installation | Mechanical mounting 5 Installation CAUTION Risk of injury due to hot surfaces. The drive system gets hot during operation, therefore the housing may be hot. Risk of skin burns. Wear personal protective equipment (protective gloves). Due to potential material defects, a broken gear unit, drive or coupling defect may cause injuries from impacts or shocks. For design of the system, suitable materials were used and a sampling test in form of a double load test accor-
ding to DIN EN 60335-2-97 was carried out. Risk of injury from impacts or shocks due to incorrectly installed or not properly engaged motor bearings. Risk due to insufficient stability and stored energy (gravity). Selection of motor bearings according to torque speci -
cations. The drive system must be secured with all provided safety equipment. Inspection for proper engagement on the motor bearing and correct screw tightening torques. WARNING Risk of injury due to electricity. Risk of electric shock. Electrical work must only be carried out by authorized electricians. Risk of injury due to electricity. Potential risk from parts that have become live due to a malfunction. The electrical connection including wiring is described in the operating and installation instructions. CAUTION Risk of injury due to malfunctions due to incorrect installa-
tion. Excessive winding of the drive system leads to possible destruction of system parts. For safe operation, end positions must be set / program-
med. Training courses by the manufacturer for specialized companies. NOTE Power supply failure, braking of machine components and other defects. For safe operation, the system must be properly installed and the end positions must be set on commissioning. Damage to the SunTop-915 by humidity ingress. On protection class IP44 systems, all cables or plugs must be protected against ingress of humidity. This ac-
tion must be taken immediately after removing the Sun-
Top-915 from its original packaging. The drive system must be installed in a position safe from rain. Important On delivery (factory settings), the SunTop-915 is in com-
missioning mode. It is necessary to set the end positions
(refer to section 5.6). Optimum use of the wireless signal. Position the antenna as freely as possible and reposition it in case of bad reception. Do not bend, shorten or extent the antenna. Observe the minimum distance between two wireless drive systems of 15 cm. 5.1 Mechanical mounting Important preliminary consideration:
The working space around the installed drive system is often limited. Therefore, get an overview of the implementa-
tion of the electrical connection (refer to section 5.2) prior to the mechanical installation and carry out respective chan-
ges, if necessary. CAUTION Risk of injury by squeezing. Horizontal clearance of at least 0.40 m between the com-
pletely unrolled part (bottom rail) and any other stationary component must be observed. NOTE Damage to electrical lines by pressure or tensile loads. All electrical lines must be laid safe from pressure or tensile loads. Observe the bending radius of the cables (at least 50 mm). Lay connection cables in a loop downwards to prevent water from running into the system. Damage to the drive system by impact loads. Always slide the drive system onto the shaft. Never ham-
mer onto the shaft or the drive system!
Never drop the drive system!
Damage to or destruction of the drive system by drilling. Never drill into the drive system!
Important Attach the SunTop-915 only to the provided mounting ele-
ments. Firmly mounted control units must be visible attached. The fabric must be mounted on the winding shaft. The pro le tube must have suf cient clearance to the motor tube. Make sure there is suf cient axial play (1 - 2 mm). Installation in pro le tubes Push the drive with suitable adapter and driving collar into the profile tube. Protect the motor cable in order to avoid damage from the driven com-
ponent. A B Secure the counterbearings to pre-
vent axial movement, e. g. screw or rivet on shaft carrier. Axially secure the drive in the bea-
ring!
Attach the fabric to the shaft!
C elero GmbH US+CA | 5 Installation: Electrical connection 5.2 Electrical connection WARNING Danger to life due to incorrect electrical connection. Risk of electric shock. Before initial commissioning, check the correct connec-
tion of the PE conductor. NOTE Damage to the SunTop-915 due to incorrect electrical con-
nection. Before initial commissioning, check the correct connec-
tion of the PE conductor. Damage to or destruction of the SunTop-915 due to ingress of humidity. For devices with protection class IP44, the customer-
provided connection of cables or plugs (wiring) must also be compliant with protection class IP44. Damage to or destruction of the SunTop-915 for models with 230 V 1 AC due to incorrect control. Switches that are preset to OFF (dead man) for drive systems must be mounted in viewing range of the Sun-
Top-915 but away from moving parts and at a height above 1.5 m. Important For electrical connection, generally no connection and dis-
connection of the connection cable or plug is necessary. Only connect when the system is disconnected from the voltage. To do so, disconnect the drive cable. 1 Use a suitable screwdriver to push the locking mecha-
nism of the device plug to the cable. 2 Disconnect the plug. 3 Insert the device plug until the locking mechanism enga-
ges. Removing and inserting the device plug Delivery con-
dition Remove plug Insert plug 2 1 3 Fig. 4 Removing and inserting the device plug 5.3 Connection example SunTop-915 120 V / 60 Hz
w s r b l b e g
r g
1 Winding thermostat 2 Device plug 3 Junction box
(outside of roller shutter case) 4 Electronic 5 Condenser sw br bl gr/ge black brown blue green/yellow L1 N PE 6 | US+CA elero GmbH 3 2 1 Fig. 5 Circuit diagram SunTop-915 120 V / 60 Hz and Wiring when using a Hirschmann plug connection STAS-3 (with bridge) 5.4 Parallel connection Important You can connect several SunTop-915 systems in parallel. To do so, please observe the maximum control capacity. 5.5 Commissioning Important On delivery, the drive system is set to commissioning mode. It is necessary to set the end positions with the elero installation cable (refer to g. 6) or a elero wand/hand transmitter (refer to g. 7). Connecting the installation cable is only for commissio-
ning of the drive system and for con guration. 5.5.1 Installation cable connection Blau (Neutralleiter) (1) Schwarz (2) Braun (3) Grn-gelb Blue (neutral wire) (1) Black (2) Brown (3) Green-yellow (4) Fig. 6 Installation cable connection Switch on power supply. Now, you can set the end positions with the elero instal-
lation cable. 5.5.2 Wireless connection (transmitter operation) Blue (neutral wire) (1) Black (2) Brown (3) Green-yellow (4) Fig. 7 Wireless connection (transmitter operation) Switch on power supply. The drive system moves up and down brie y. Now, the drive system is in wireless operation. Now, you can program the transmitter(s). 5.6 End position and relief settings Setting of end positions and relief can either be carried out by means of elero installation cable (ensure proper con-
nection according to section 5.5.1) or by means of a programmed transmitter. Programming a transmitter for a drive system is descri-
bed in section 5.7. Relief function | End position settings Important preliminary consideration:
Before carrying out the end position settings, decide on a certain relief function (different combinations available according to the following models). This will save you unnecessary time and effort during con-
guration!
Press one of the drive buttons until the drive system indica-
tes switchover to setting mode with a short automatic stop. Now, you can set the end positions. After setting both end positions, the setting mode is closed. 5.6.1 Relief function for end position(s) If one end position was programmed to limit stop, an additi-
onal relief function can be activated for the fabric. Important The relief function is only active in wireless operation. Activation of the relief function (for options B to D) is carried out in one step with programming of the end positions (refer to sections 5.6.7 to 5.6.9)!
5.6.2 Relief function at the upper stop For option B (refer to section 5.6.7) and option C (refer to section 5.6.8):
Activating the relief function at the upper limit stop 1 Using the installation cable or a programmed trans-
mitter, keep the UP button pressed from step
(section 5.6.7 and 5.6.8) and press additionally
(simultaneously) the DOWNbutton . Keep both buttons pressed until the fabric stops. The relief function at the upper limit stop is activated. 5.6.3 Relief function at the lower stop For option C (refer to section 5.6.8) and option D (refer to section 5.6.9):
Activating the relief function at the lower limit stop 1 In a medium fabric position, using the installation cable or a programmed transmitter, keep the DOWN button pressed from step (section 5.6.8 and 5.6.9) and press additionally (simultaneously) the UPbutton . Keep both buttons pressed until the fabric stops. The relief function at the lower limit stop is activated. 5.6.4 Changing / deleting of end positions and deleting the relief function It is not possible to change or delete one individual end position. This is always carried out in pairs (upper and lower end position at once). By deleting the end positions, also the setting of the optio-
nal relief function is lost. Important Complete, uninterrupted up and down movement is neces-
sary to adapt the fabric protection system to the fabric. Changing / deleting of end positions 1 In a medium fabric position, using the installation cable or a programmed transmitter, simultaneously press both direction buttons ( and ) and keep them pressed until the drive system brie y moves up and down. Deleting the end position settings is completed. The end positions can be reset. 5.6.5 Programming or deleting additional fabric positions Intermediate position programming:
refer to transmitter instructions. Ventilation position programming:
refer to transmitter instructions. Intermediate position deleting:
refer to transmitter instructions. Ventilation position deleting:
refer to transmitter instructions. 5.6.6 Four options for end position settings Four different combinations of end position settings are available that can be selected according to the technical requirements of the fabric. End position settings (4 options) A Upper and lower end position freely con gurable B Fixed upper end position, lower end position freely con gurable C Fixed upper and lower end position D Upper end position freely con gurable, xed lower end position Fig. 8 Options of end position settings for SunTop-915 5.6.7 Option A: Upper and lower end position freely con gurable Option A:
Upper and lower end position freely con gurable In a medium fabric position, using the installation cable or a programmed transmitter, press the UP button until the fabric has reached the desired upper end position. The drive system starts, stops brie y and starts again (as long as the UP button is pressed). Corrections can be made with the buttons and
. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Press the DOWN button again, until the fabric has reached the desired lower end position. The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). Corrections can be made with the buttons and
. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. End position setting of option A is completed. Fig. 9 End position setting option A:
elero GmbH US+CA | 7 End position settings | Transmitter programming 5.6.8 Option B: Fixed upper end position, lower end position freely con gurable Option B: Fixed upper end position, lower end position freely con gurable In a medium fabric position, using the installation cable or a programmed transmitter, press the UP button until the fabric has reached the desired upper end position (to upper limit stop). The drive system starts, stops brie y and starts again (as long as the UP button is pressed). The drive system automatically stops when reaching the upper limit stop. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Optional: Activation of the relief function for the upper limit stop: refer to section 5.6.2. Press the DOWN button again, until the fabric has reached the desired lower end position. The drive system starts, stops brie y and starts again (as long as the button is pressed). Corrections can be made with the buttons and
. Keep the UP button pressed until the drive sys-
tem stops automatically. End position setting of option B is completed. Fig. 10 End position setting option B:
5.6.9 Option C:
5.6.10 Option D:
Upper end position freely con gurable, xed lower end position Option D: Upper end position freely con gurable, xed lower end position In a medium fabric position, using the installation cable or a programmed transmitter, press the UP button until the fabric has reached the desired upper end position. The drive system starts, stops brie y and starts again (as long as the button is pressed). Corrections can be made with the buttons and
. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Press the DOWN button again, until the fabric has reached the lower end position (to bottom limit stop). The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). The drive system automatically stops when reaching the lower limit stop. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option D is completed. Fixed upper and lower end position Fig. 12 End position setting option D:
Option C: Fixed upper and lower end position In a medium fabric position, using the installation cable or a programmed transmitter, press the UP button until the fabric has reached the desired upper end position (to upper limit stop). The drive system starts, stops brie y and starts again (as long as the UP button is pressed). The drive system automatically stops when reaching the upper limit stop. Keep the DOWN button pressed until the drive system stops automatically. The upper end position is set. Optional: Activation of the relief function for the upper limit stop: refer to section 5.6.2. Press the DOWN button again, until the fabric has reached the lower end position (to bottom limit stop). The drive system starts, stops brie y and starts again (as long as the DOWN button is pressed). The drive system automatically stops when reaching the lower limit stop. Keep the UP button pressed until the drive sys-
tem stops automatically. The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option C is completed. Fig. 11 End position setting option C:
5.7 Transmitter programming Important Requirement: The drive system must be in wireless opera-
tion. If the end positions are not programmed, the fabric is loosened from the winding shaft. Programming the ( rst) transmitter Instruction 1 Disconnecting and recon-
necting the power supply 2 On the transmitter to be programmed, press the programming button P for approx. 1 second. 3 Immediately (max. 1 se-
cond) after start of the up movement, press the UP button . 4 Immediately (max. 1 se-
cond) after start of the down movement, press the DOWN button . Result For approx. 5 minutes, the drive system is in programming mode. The status indicator ashes. Now (for approx. 2 minutes), the drive system is in programming mode
(up and down move-
ment). The status indicator ashes brie y. The fabric stops brie y, moves on, stops and moves downwards. The status indicator ashes brie y. The drive system stops. The ( rst) transmitter is programmed. 8 | US+CA elero GmbH Transmitter programming | Troubleshooting | Repair 5.8 Programming additional transmitters(s) A maximum of 16 transmitters can be programmed. Programming additional transmitters(s) Instruction 1 For three seconds, on a already programmed trans-
mitter press simultaneously for 3 seconds the UPbutton , the DOWNbutton and the programming button P.
(alternative to above line) Disconnecting and recon-
necting the power supply 2 On the (additional) transmitter to be program-
med, press the program-
ming button P. 4 On the (additional) transmitter to be program-
med, immediately (max. 1 second) after start of the up movement, press the UP button . 5 On the (additional) transmitter to be program-
med, immediately (max. 1 second) after start of a down movement, press the DOWNbutton . Result The status indicator ashes. The drive sys-
tem is in programming mode (up and down movement). For approx. 5 minutes, the drive system is in programming mode. The status indicator ashes brie y. The drive system is (for approx. 2 minutes) in programming mode
(up and down move-
ment). The status indicator ashes brie y. The fabric stops brie y, moves on, stops and moves downwards. The status indicator ashes brie y. The drive system stops. Programming of the additional transmitter is complete. Stopping the bidirectional wireless programming mode:
Press the STOP button for at least 6 seconds until the sta-
tus indicator is blinking (transmitter-dependent). Important Complete, uninterrupted up and down movement is neces-
sary to adapt the fabric protection system to the fabric. 5.9 Technical data The separately available technical data sheet will provide you with an overview of the most important technical para-
meters. Troubleshooting 6 Problem /
malfunction Drive system stops during movement Remedy, correction Set end posi-
tions Possible cause End positions not correctly set Drive system is in setting mode Drive system stops after a short period of time End positions have been saved Stiff fabric Set second end position Check smooth running of the fabric Problem /
malfunction Drive system only runs in one direction Drive system does not react Program-
ming of end positions not possible Possible cause Connection error Remedy, correction Check connec-
tion No power supply Temperature limiter has triggered Random drive movements The distance to the end position or to the limit stop is too short Check power supply Have the drive system cool down Delete end positions Reset end positions The drive sys-
tem must run, stop brie y and start again
(as long as a button on the elero installa-
tion cable or a programmed transmitter is pressed). Fig. 13 SunTop-915 troubleshooting 7 8 Servicing The SunTop-915 is maintenance-free. Cleaning WARNING Risk of injury due to electricity. Risk of electric shock. Risk due to potential live parts. Only carry out cleaning when the system is disconnected from the voltage. To do so, disconnect the drive cable. Clean the product surface only with a soft, clean and dry cloth. Repair 9 In case of questions, please contact your local specialist. Please always provide the following information:
Article number and designation on name plate Type of defect Previous and unusual occurrences Circumstances Own assumption 10 Address elero GmbH Antriebstechnik Linsenhofer Str. 65 72660 Beuren Germany Phone: +49 7025 13-01 Fax:
+49 7025 13-212 info@elero.de www.elero.com If you require a contact outside of Germany, please visit our website. elero GmbH US+CA | 9 Declaration of Conformity | UL approval | Homologation UL 13 US: Addendum to the manual UL approval This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference recieved, inclu-
ding interference that may cause undesired operation. Any changes or modi cations made to this device without the express permission of the manufacturer may void the users authority to operate this device. 14 CA: Addendum au manuel Homologation UL Le prsent appareil est conforme aux CNR-210 (et FCC part 15) dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 11 Disposal / scrapping After unpacking the system, dispose of the packaging mate-
rial according to applicable regulations. After the last use, dispose of the product according to appli-
cable regulations. Scrapping When scrapping the product, applicable international, natio-
nal and local rules and regulations must be complied with. Please observe the recycling and dismantling properties of materials and components as well as environmental and health risks during recycling and disposal. Material groups like different plastics and metals must be sorted and put into the recycling system or disposed of. Disposal of electrotechnical and electrical components Disposal and recycling of electrotechnical and electrical components must be carried out according to the applicable laws or national regulations. 12 EC Declaration of Conformity EG-KONFORMITTSERKLRUNG Wir erklren hiermit, dass das/die nachfolgend genannte/n Produkte der Maschinenrichtlinie 2006/42/EG entspricht/entsprechen. Produktbezeichnung: Rohrmotor SunTop M-867 / -868 / -915 alle Varianten SunTop L-868 / -915 alle Varianten Beschreibung:
Einsteckantrieb fr Markisen mit 867 / 868 / 915 MHz Funkempfnger Die bereinstimmung der/s bezeichneten Produkte/s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen bercksichtigt:
R&TTE-Richtlinie 1999/5/EG Niederspannungsrichtlinie 2006/95/EG DIN EN 14202:2004 DIN EN 60335-2-97 (VDE 0700-97):2010 Beuren, 30.05.2012 Ralph Trost
-CE-Beauftragter-, -Doku-Bevollmchtigter-
Fig. 14 EC Declaration of Conformity SunTop-915, type M and L elero GmbH Antriebstechnik Linsenhofer Strae 65 D-72660 Beuren Phone: +49 7025 13-01 Fax: +49 7025 13-212 info@elero.de www.elero.com Technical modifications reserved
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2013-08-09 | 918.3 ~ 918.3 | DXT - Part 15 Low Power Transceiver, Rx Verified | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2013-08-09
|
||||
1 | Applicant's complete, legal business name |
elero GmbH Antriebstechnik
|
||||
1 | FCC Registration Number (FRN) |
0019740679
|
||||
1 | Physical Address |
Maybachstrasse 30
|
||||
1 |
Schlierbach, N/A 73278
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
YBU
|
||||
1 | Equipment Product Code |
RT915
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
M******** H******
|
||||
1 | Title |
Dr.
|
||||
1 | Telephone Number |
+49-7********
|
||||
1 | Fax Number |
+49-7********
|
||||
1 |
m******@elero.de
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
elero GmbH
|
||||
1 | Name |
M****** Z********
|
||||
1 | Physical Address |
Germany
|
||||
1 |
i******@elero.de
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
elero GmbH
|
||||
1 | Name |
R****** P****
|
||||
1 | Physical Address |
Germany
|
||||
1 |
i******@elero.de
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXT - Part 15 Low Power Transceiver, Rx Verified | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Tubular Motor with Electronic Limit Switch | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
NICE S.p.A.
|
||||
1 | Name |
E******** C****
|
||||
1 | Telephone Number |
39042******** Extension:
|
||||
1 | Fax Number |
00390********
|
||||
1 |
e******@niceforyou.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 918.30000000 | 918.30000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC