all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
15 UserMan-US r1 | Users Manual | 1.06 MiB | August 08 2019 | |||
1 |
|
06 LabelSmpl-US r2 | ID Label/Location Info | 1.29 MiB | August 08 2019 | |||
1 |
|
08 ExtPho | External Photos | 694.56 KiB | August 08 2019 | |||
1 |
|
09 IntPho | Internal Photos | 1003.26 KiB | August 08 2019 | |||
1 |
|
10 TSup | Test Setup Photos | 134.84 KiB | August 08 2019 | |||
1 |
|
14 TestRpt DTS WiFi r2 | Test Report | 3.43 MiB | August 08 2019 | |||
1 |
|
17 AntSpec | Operational Description | 69.44 KiB | August 08 2019 | |||
1 |
|
18 RFExp r1 | RF Exposure Info | 178.81 KiB | August 08 2019 |
1 | 15 UserMan-US r1 | Users Manual | 1.06 MiB | August 08 2019 |
You can experience the various advanced features of the product with the app, just try and do it yourself. Main fuctionAlarm recordingAlarm notificationLinkage alarm settingCreate scenes to associate two devices.Device sharing Allow others to control the devicePush notificationOpen/close push notificationRemove deviceRestore default settings; Delete and add the device again to clear the record by APP.1. Download APPDownload the "Smart life" app from APP Store or Google Playto your mobile.2. Register and Login Launch the "Smart life" app.To register,enter your mobile phone number or email address,create a password ,then login to the app.Login if you have an account already.3. Add DevicePower on the smart sensor which default's mode is Smart WiFi mode.Select the + symbol on the top right-hand corner.Select your product type and follow the instructions of the app.If the connecting fails,try using AP ModeOn the Add device page select AP Mode on the top right-hand corner and follow the instructions of the app.Finally,have fun!Product configurationHow to use ?Whats in the box ?Whats the App User Interface Like ? Experience Advanced FeaturesLED StateMake Your Home Smarter Alarm recording Turn on/off the alarm1. Open mousetrap2. Install batteries3. Put the bait inside the food boxTips:1. Do not place the mousetrap cover in the water. The mousetrapbody and food box can be removed for cleaning.2. When the mousetrap is triggered once, the clear button must be turned on and the mousetrap will work again.3. Put the mousetrap within the 2.4G Hz Wi-Fi network coverage.4. High current is generated when triggering, please take care.5. Please use 1.5V AA x 4 batteryMOUSETRAPINSTRUCTIONDevice StatusSmart Wi-FiAP modeTriggeredSleeping modeResetLED StateIndicator flashes quicklyIndicator flashes slowlyLED is on for 2 minutes LED Flash once in 3 seconds until the indicator is manually turned offIndicator lights up for 4s and after 2 seconds lights off, device goes into configuration modeGet Started with Tuya Smart AppSpecificationsBattery:1.5V - AA *4Standby current:13uAMax current:700mAStandby lifetime:5 yearsWorking lifetime:1 year1 times/dayWireless type:2.4GHzWireless standard:IEEE 802.11b/g/nWireless range:45MOperating Temperature:0 40 (32F104F) Operating Humidity: 20% 85%Storage Temperature:0 60 (32F 140F)Storage Humidity:0% 90% Size:222mm(L) x112mm(W) x 120mm(H)Mousetrap top coverMousetrap x 1Mousetrap main bodyBattery boxReset buttonFood boxSwitch/clear buttonLED indicatorRemove mousetraptop cover1 Take out foodbox2Take out mousetraptop cover3Open battery cover1Install 4 x AA batteries2Replace the cover3Put bait here1Replace mousetrap2User manual x 1Notice: If failed to reset, please take off the batteries then trigger the device and install battery again .wait for 10-20s.How to reset?(1) Press the reset button for 6 seconds till the indicator flash rapidly.Then device turns to smart wifi mode.(2) Press the reset button again for 6 seconds till the indicator flash slowly. The device turns to AP mode.FCC ID: Model: WFMZ1
1 | 08 ExtPho | External Photos | 694.56 KiB | August 08 2019 |
- Page 1 of 3 -
Report No.: MTi190618E124-1 APPENDIX 1: EUT PHOTO Photo 1 (For Model WFMZ1) Photo 2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 2 of 3 -
Report No.: MTi190618E124-1 Photo 3 Photo 4 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 3 of 3 -
Report No.: MTi190618E124-1 Photo 5 Photo 6 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
----END OF REPORT----
1 | 09 IntPho | Internal Photos | 1003.26 KiB | August 08 2019 |
- Page 1 of 4 -
Report No.: MTi190618E124-1 APPENDIX 1: EUT PHOTO Photo 1 (For Model WFMZ1) Photo 2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 2 of 4 -
Report No.: MTi190618E124-1 Photo 3 Photo 4 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 3 of 4 -
Report No.: MTi190618E124-1 Photo 5 PCB Antenna Photo 6 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 4 of 4 -
Report No.: MTi190618E124-1 Photo 7 Photo 8 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
----END OF REPORT----
1 | 14 TestRpt DTS WiFi r2 | Test Report | 3.43 MiB | August 08 2019 |
Test Report FCCID: VII-WFMZ1 Date of issue: June 19, 2019 Report Number:
MTi190618E124 Sample Description:
WiFi Mouser Mod el(s):
Applicant:
Address:
WFMZ1 Elexa Consumer Products, Inc. 2275 Half Day Road, Suite 160, Bannockburn, IL60015, United States. Date of Test:
May 31, 2019 to June 19, 2019 Shenzhen Microtest Co., Ltd. http://www.mtitest.com This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Table of Contents
- Page 2 of 47 -
Report No.: MTi190618E124 1 GENERAL INFORMATION .......................................................................................................................................... 5 1.1 1.2 1.3 1.4 1.5 DESCRIPTION OF EUT ................................................................................................................................................... 5 OPERATION CHANNEL LIST .............................................................................................................................................. 6 TEST CHANNEL LIST ....................................................................................................................................................... 6 ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 6 DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 6 SUMMARY OF TEST RESULTS .................................................................................................................................... 7 TEST FACILITIES AND ACCREDITATIONS ..................................................................................................................... 8 3.1 3.2 3.3 3.4 TEST LABORATORY ........................................................................................................................................................ 8 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 8 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 8 TEST SOFTWARE ........................................................................................................................................................... 8 EQUIPMENT LIST ...................................................................................................................................................... 9 TEST RESULT ........................................................................................................................................................... 10 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.1.1 5.1.2 5.4.1 5.4.2 5.4.3 5.4.4 5.2.1 5.2.2 5.2.3 5.2.4 5.3.1 5.3.2 5.3.3 5.3.4 ANTENNA REQUIREMENT ............................................................................................................................................. 10 Standard requirement ....................................................................................................................................... 10 EUT Antenna ..................................................................................................................................................... 10 PEAK OUTPUT POWER ................................................................................................................................................. 11 Limit .................................................................................................................................................................. 11 Test setup .......................................................................................................................................................... 11 Test procedure ................................................................................................................................................... 11 Test results......................................................................................................................................................... 12 POWER SPECTRAL DENSITY ........................................................................................................................................... 13 Limit .................................................................................................................................................................. 13 Test Setup .......................................................................................................................................................... 13 Test Procedure ................................................................................................................................................... 13 Test Results ........................................................................................................................................................ 14 CONDUCTED EMISSION ................................................................................................................................................ 17 Limits ................................................................................................................................................................. 17 Test setup .......................................................................................................................................................... 17 Test procedure ................................................................................................................................................... 18 Test results......................................................................................................................................................... 18 RADIATED SPURIOUS ................................................................................................................................................... 19 Limits ................................................................................................................................................................. 19 Test setup .......................................................................................................................................................... 20 Test procedure ................................................................................................................................................... 21 Test results......................................................................................................................................................... 22 Radiation emission ....................................................................................................................................... 22 Band edge - radiated .................................................................................................................................... 26 Spurious Emission in Restricted Band 3260MHz-18000MHz ........................................................................ 28 BAND EDGE - CONDUCTED ........................................................................................................................................... 29 Limits ................................................................................................................................................................. 29 Test setup .......................................................................................................................................................... 29 Test procedure ................................................................................................................................................... 29 Test results......................................................................................................................................................... 30 6DB BANDWIDTH ....................................................................................................................................................... 33 Limit .................................................................................................................................................................. 33 Test setup .......................................................................................................................................................... 33 Test procedure ................................................................................................................................................... 33 Test results......................................................................................................................................................... 34 DUTY CYCLE .............................................................................................................................................................. 40 5.8.1 Conformance Limit ............................................................................................................................................ 40 5.8.2 Measuring Instruments ..................................................................................................................................... 40 5.5.1 5.5.2 5.5.3 5.5.4 5.5.4.1 5.5.4.2 5.5.4.3 5.7.1 5.7.2 5.7.3 5.7.4 5.6.1 5.6.2 5.6.3 5.6.4 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 2 3 4 5
- Page 3 of 47 -
Report No.: MTi190618E124 5.9 5.8.3 5.8.4 5.8.5 Test Setup .......................................................................................................................................................... 40 Test Procedure ................................................................................................................................................... 40 Test Results ........................................................................................................................................................ 41 SPURIOUS RF CONDUCTED EMISSIONS ........................................................................................................................... 42 5.9.1 Conformance Limit ............................................................................................................................................ 42 5.9.2 Measuring Instruments ..................................................................................................................................... 42 Test Setup .......................................................................................................................................................... 42 5.9.3 Test Procedure ................................................................................................................................................... 42 5.9.4 5.9.5 Test Results ........................................................................................................................................................ 42 PHOTOGRAPHS OF THE TEST SETUP ................................................................................................................................ 46 PHOTOGRAPHS OF THE EUT ............................................................................................................................................ 47 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 4 of 47 -
Report No.: MTi190618E124 Test Result Certification Applicants name:
Elexa Consumer Products, Inc. Address:
2275 Half Day Road, Suite 160, Bannockburn, IL60015, United States. Manufacture's Name:
Elexa Consumer Products, Inc. Address:
2275 Half Day Road, Suite 160, Bannockburn, IL60015, United States. Product name:
WiFi Mouser Trademark:
Dome Model name:
WFMZ1 Standards:
Test Procedure:
FCC Part 15.247 ANSI C63.10-2013 KDB 558074 D01 DTS Meas Guidance v05r02 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by:
Jone Lee June 19, 2019 Reviewed by:
Blue Zheng June 19, 2019 Approved by:
Smith Chen June 19, 2019 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 5 of 47 -
Report No.: MTi190618E124 1 General information 1.1 Description of EUT Product name:
WiFi Mouser Model name:
Serial Model:
Model difference:
WFMZ1 N/A N/A Operation frequency:
802.11b/g/n20:2412~2462 MHz Modulation type:
IEEE 802.11g/n (HT20) : OFDM IEEE 802.11b : DSSS (DBPSK, DQPSK, CCK) Bit Rate of transmitter:
(64QAM, 16QAM, QPSK, BPSK) 802.11b:11/5.5/2/1 Mbps 802.11g:54/48/36/24/18/12/9/6Mbps 802.11n(20MHz) use 800 ns GI:
65.0/58.5/52.0/39.0/26.0/19.5/13.0/6.5 Mbps (MCS0~MCS7) Antenna type:
PCB Antenna Antenna gain:
1dBi Max. output power:
14.24dBm Power supply:
DC 6V from Battery Battery:
DC 1.5V*4 cell AA alkaline batter Adapter information:
N/A Hardware version:
NAS-MA01W0 -V Software version:
QIO_1.0.7 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 6 of 47 -
Report No.: MTi190618E124 1.2 Operation channel list Channel List for 802.11b/g/n(20) Channel Frequency (MHz) Channel Frequency (MHz) 01 02 03 04 05 06 2412 2417 2422 2427 2432 2437 07 08 09 10 11
\
2442 2447 2452 2457 2462
\
1.3 Test channel list Channel List for 802.11b/g/n(20) Channel Low Middle High Channel Frequency (MHz) 01 06 11 2412 2437 2462 1.4 Ancillary equipment list Equipment Model S/N Manufacturer Certificate type
/
/
/
/
/
1.5 Description of Support Units The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment Brand Model/Type No. Series No. Note
/
/
/
/
/
/
/
/
/
/
/
/
Note:
(1)The support equipment was authorized by Declaration of Confirmation.
(2)For detachable type I/O cable should be specified the length in cm inLengthcolumn. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 7 of 47 -
Report No.: MTi190618E124 2 Summary of Test Results Test procedures according to the technical standards:
No. Standard Section Test Item Result Remark 1 2 3 4 5 6 7 8 15.203 Antenna Requirement 15.247 (b) Peak Output Power 15.247 (e) Power Spectral Density 15.207 Conducted Emission 15.247 (d) & 15.209 Radiated Spurious Emission 15.205 Band Edge Emission 15.247 (a)(2) 6dB Bandwidth 15.205 Spurious RF Conducted Emissions Pass Pass Pass N/A Pass Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 8 of 47 -
Report No.: MTi190618E124 3 Test Facilities and Accreditations 3.1 Test laboratory Test Laboratory Shenzhen Microtest Co., Ltd Location No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China FCC Registration No.:
FCC Registration No.: 448573 3.2 Environmental conditions Temperature:
15C~35C Humidity 20%~75%
Atmospheric pressure 98kPa~101kPa 3.3 Measurement uncertainty The reported uncertainty of measurement y Uwhere expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2providing a level of confidence of approximately 95
%
No. Item Uncertainty 1 2 3 4 5 6 7 Conducted Emission Test RF power, conducted Spurious emissions, conducted All emissions, radiated(<1G) All emissions, radiated(>1G) Temperature Humidity 1.38dB 0.16dB 0.21dB 4.68dB 4.89dB 0.5C 2%
3.4 Test software Software Name Manufacturer RF Test System Farad Model LZ-RF Version Lz_Rf 3A3 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 9 of 47 -
Report No.: MTi190618E124 4 Equipment list Equipment Equipment Manufactur No. MTI-E001 MTI-E003 Name Spectrum Analyzer Spectrum Analyzer er Model Serial No. Calibration date Due date Agilent E4407B MY41441082 2018/09/18 2019/09/17 R&S ESCI MTI-E003 2018/09/18 2019/09/17 MTI-E004 EMI Test Receiver MTI-E006 Broadband antenna Rohde&schw arz schwarabeck MTI-E007 Horn antenna schwarabeck ESPI 1000314 2018/09/18 2019/09/17 VULB916 3 BBHA912 0D 872 2018/09/18 2019/09/17 1201 2018/09/18 2019/09/17 MTI-E014 amplifier America 8447D 3113A06150 2018/09/18 2019/09/17 MTI-E015 Immunity Signal Schloder CDG6000 Conduction 126A1343/20 15 2018/09/18 2019/09/17 MTI-E016 Generator Coupled decoupling network Schloder CND M2/M3 A2210332/20 15 2018/09/18 2019/09/17 MTI-E034 amplifier Agilent 8449B 3008A02400 2018/09/18 2019/09/17 MTI-E037 MTI-E040 Artificial power network Spectrum analyzer Schwarzbeck NSLK812 7
#841 2018/09/18 2019/09/17 Agilent N9020A MY49100060 2018/09/18 2019/09/17 MTI-E041 Signal generator Agilent N5182A MY49060455 2018/09/18 2019/09/17 MTI-E042 Analog signal generator MTI-E043 Power sensor Agilent E4421B GB40051240 2018/09/18 2019/09/17 Dare RPR3006 16I00054SN Instruments W O16 2018/09/18 2019/09/17 MTI-E047 10dB attenuator Mini-Circuits UNAT-10+
15542 2018/09/18 2019/09/17 MTI-E049 MTI-E050 spectrum analyzer PSG Signal generator Active Loop Rohde&schw arz FSP-38 100019 2018/09/18 2019/09/17 Agilent E8257D MY46520873 2018/09/18 2019/09/17 MTI-E061 Antenna 9kHz -
Schwarzbeek MTI-E052 30MHz 18-40GHz amplifier Chengdu step Micro Technology MTI-E053 15-40G Antenna Schwarzbeek MTI-E058 Artificial power network Schwarzbeck FMZB 1519 B ZLNA-18-
40G-21 00044 2018/09/18 2019/09/17 1608001 2018/09/18 2019/09/17 BBHA917 BBHA91705 82 0 NSLK812 7 2018/09/18 2019/09/17
#841 2018/09/18 2019/09/17 Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 10 of 47 -
Report No.: MTi190618E124 5 Test Result 5.1 Antenna requirement 5.1.1 Standard requirement 15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device 5.1.2 EUT Antenna The EUT antenna is PCB antenna (1dBi). It comply with the standard requirement. In case of replacement of broken antenna the same antenna type must be used. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 11 of 47 -
Report No.: MTi190618E124 5.2 Peak output power 5.2.1 Limit FCC Part15 Subpart C Section Test Item Limit Frequency Range
(MHz) Result 15.247(b)(3) Peak output power 5.2.2 Test setup EUT 1 watt or 30dBm 2400-2483.5 Pass Power meter 5.2.3 Test procedure The EUT was directly connected to the Power meter. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 12 of 47 -
Report No.: MTi190618E124 5.2.4 Test results 802.11b Test Channel Frequency
(MHz) Maximum Peak Conducted Output Power(dBm) Limit (dBm) CH01 CH06 CH11 2412 2437 2462 802.11g 14.24 13.85 13.53 30 30 30 Test Channel Frequency
(MHz) Maximum Peak Conducted Output Power(dBm) Limit (dBm) CH01 CH06 CH11 2412 2437 2462 802.11n20 12.94 12.99 11.03 30 30 30 Test Channel Frequency
(MHz) Maximum Peak Conducted Output Power(dBm) Limit (dBm) CH01 CH06 CH11 2412 2437 2462 12.89 12.84 12.92 30 30 30 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 13 of 47 -
Report No.: MTi190618E124 5.3 Power spectral density 5.3.1 Limit FCC Part15 Subpart C Section Test Item Limit 15.247 Power Spectral Density 8 dBm
(in any 3kHz) Frequency Range
(MHz) Result 2400-2483.5 Pass 5.3.2 Test Setup 5.3.3 Test Procedure a. The EUT tested system was configured as the statements of 2.1 unless otherwise a special operating condition is specified in the follows during the testing. b. Set analyzer center frequency to DTS channel center frequency. c. Set the span to 1.5 times the DTS channel bandwidth. d. Set the RBW 3 kHz. e. Set the VBW 3 x RBW. f. Detector = peak. g. Sweep time = auto couple. h. Trace mode = max hold. i. Allow trace to fully stabilize. j. Use the peak marker function to determine the maximum amplitude level. k. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 14 of 47 -
Report No.: MTi190618E124 5.3.4 Test Results Frequency 2412 MHz 2437 MHz 2462 MHz 802.11b Power Density
(dBm/3kHz) Limit
(dBm/3kHz)
-8.743
-8.969
-9.696 8 8 8 Result Pass Pass Pass TX CH01 TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 15 of 47 -
Report No.: MTi190618E124 802.11g Frequency 2412 MHz 2437 MHz 2462 MHz Power Density Limit
(dBm/3kHz) 8(dBm/3kHz)
-12.571
-12.384
-14.336 8 8 8 Result Pass Pass Pass TX CH01 TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 16 of 47 -
Report No.: MTi190618E124 Frequency 2412 MHz 2437 MHz 2462 MHz 802.11n20 Power Density Limit
(dBm/3kHz) 8(dBm/3kHz)
-13.016
-13.029
-14.730 8 8 8 Result Pass Pass Pass TX CH01 TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 17 of 47 -
Report No.: MTi190618E124 5.4 Conducted emission 5.4.1 Limits According to FCC Part 15.207(a) and KDB 174176 D01 Line Conducted FAQ v01r01. Note FREQUENCY (MHz) 0.15 -0.5 0.50 -5.0 5.0 -30.0 Class B (dBuV) Quasi-peak 66 - 56 *
56.00 60.00 Average 56 - 46 *
46.00 50.00
(1)The tighter limit applies at the band edges.
(2)The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range. 5.4.2 Test setup Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Note: 1.Support units were connected to second LISN. 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80cm from other units and other metal planessupport. units.Vertical ReferenceGround Plane40cm80cmTest ReceiverHorizontal ReferenceGround PlaneEUT LISN- Page 18 of 47 -
Report No.: MTi190618E124 5.4.3 Test procedure a. EUT Operating Conditions The EUT was configured for testing in a typical fashion (as a customer would normally use it). The EUT has been programmed to continuously transmit during test. This operating condition was tested and used to collect the included data. b. The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth Setting 10 dB 0.15 MHz 30 MHz 9 kHz c. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. d. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. e. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. f. LISN at least 80 cm from nearest part of EUT chassis. For the actual test configuration, please refer to the related Item EUT Test Photos. 5.4.4 Test results Note: The device is a DC power supply and does not apply to conducted emissions. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 19 of 47 -
Report No.: MTi190618E124 5.5 Radiated spurious 5.5.1 Limits 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed. Frequency
(MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 Above 960 Field Strength Measurement Distance
(micorvolts/meter)
(meters) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 300 30 30 3 3 3 3 Spectrum Parameter Attenuation Start Frequency Stop Frequency Setting Auto 1000 MHz 10th carrier harmonic RB / VB (emission in restricted 1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for band) Receiver Parameter Attenuation Average Setting Auto Start ~ Stop Frequency 9kHz~150kHz / RB 200Hz for QP Start ~ Stop Frequency 150kHz~30MHz / RB 9kHz for QP Start ~ Stop Frequency 30MHz~1000MHz / RB 120kHz for QP Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 20 of 47 -
Report No.: MTi190618E124 5.5.2 Test setup Radiated emission test-up frequency below 30MHz Radiated emission test-up frequency 30MHz~1GHz Radiated emission test-up frequency above 1GHz 3m Turntabl e EUT 1.5 m 1.5 m 4m Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Amplifie r Test Receiver 5.5.3 Test procedure
- Page 21 of 47 -
Report No.: MTi190618E124 a. EUT operating conditions. The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. b. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz. For frequencies above 1GHz, any suitable measuring distance may be used. c. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter open area test site. The table was rotated 360 degrees to determine the position of the highest radiation. d. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. e. For emission measurements above 1 GHz, the EUT shall be placed at a height of 1.5 m above the floor on a support that is RF transparent for the frequencies of interest. Final measurements for the EUT require a measurement antenna height scan of 1 m to 4 m. f. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. g. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed. h. For the actual test configuration, please refer to the related Item EUT Test photos. Note: Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 22 of 47 -
Report No.: MTi190618E124 5.5.4 Test results 5.5.4.1 Radiation emission Below 30MHz EUT WiFi Mouser Model Name WFMZ1 Relative Humidity: 52%
Pressure Test Mode TX 1010 hPa Phase:
Test Voltage H DC 6V from battery Freq.
(MHz)
--
--
Reading Limit
(dBuV/m)
(dBuV/m)
--
--
--
--
Margin
(dB)
--
--
State P/F Pass Pass Note:
The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Distance extrapolation factor =40 log (specific distance/test distance)(dB);
Limit line = specific limits(dBuV) + distance extrapolation factor. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 23 of 47 -
Report No.: MTi190618E124 Between 30MHz 1GHz All the modulation modes have been tested, the report only shows the worst mode. The worst mode is 802.11b CH11, the worst result was report as below:
EUT Relative Humidity:
Pressure Test Mode WiFi Mouser Test Voltage 1010 hPa Phase:
52%
TX H Model Name WFMZ1 DC 6V from battery Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 24 of 47 -
Report No.: MTi190618E124 EUT Relative Humidity:
Pressure Test Mode WiFi Mouser Model Name WFMZ1 52%
1010 hPa TX Phase:
V Test Voltage DC 6V from battery Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 25 of 47 -
Report No.: MTi190618E124 1G-25GHz Note: (1) All Readings are Peak Value (VBW=3MHz) and AV Value (VBW=10Hz).
(2) Emission Level= Antenna Factor + Cable Loss + Read Level - Preamp Factor
(3) All other emissions more than 20dB below the limit. All the modulation modes have been tested, and the worst result was report as below:
For 802.11b Frequency Read Cable Antenna Preamp Emission Limits Margin Remark Comment Level loss Factor Factor Level
(MHz)
(dBV)
(dB) dB/m
(dB)
(dBV/m)
(dBV/m)
(dB) Low Channel (2412 MHz)(802.11b)--Above 1G 4824.161 63.02 4.36 32.92 45.53 54.77 74.00
-19.23 Pk Vertical 4824.161 40.40 4.36 32.92 45.53 32.15 54.00
-21.85 AV Vertical 7236.396 60.00 5.02 37.63 45.56 57.09 74.00
-16.91 Pk Vertical 7236.396 43.72 5.02 37.63 45.56 40.81 54.00
-13.19 AV Vertical 4824.154 61.08 4.36 32.92 45.53 52.83 74.00
-21.17 Pk Horizontal 4824.154 42.66 4.36 32.92 45.53 34.41 54.00
-19.59 AV Horizontal 7236.168 63.09 5.02 37.63 45.56 60.18 74.00
-13.82 Pk Horizontal 7236.168 46.36 5.02 37.63 45.56 43.45 54.00
-10.55 AV Horizontal Middle Channel (2437 MHz)(802.11b)--Above 1G 4874.112 62.63 4.41 33.01 45.76 54.29 74.00
-19.71 Pk Vertical 4874.112 42.65 4.41 33.01 45.76 34.31 54.00
-19.69 AV Vertical 7311.247 59.95 5.02 37.68 45.59 57.06 74.00
-16.94 Pk Vertical 7311.247 46.90 5.02 37.68 45.59 44.01 54.00
-9.99 AV Vertical 4874.132 60.38 4.41 33.01 45.76 52.04 74.00
-21.96 Pk Horizontal 4874.132 48.02 4.41 33.01 45.76 39.68 54.00
-14.32 AV Horizontal 7311.085 59.51 5.02 37.68 45.59 56.62 74.00
-17.38 Pk Horizontal 7311.085 41.89 5.02 37.68 45.59 39.00 54.00
-15.00 AV Horizontal High Channel (2462 MHz)(802.11b)--Above 1G 4924.169 65.50 4.50 33.26 46.07 57.19 74.00
-16.81 Pk Vertical 4924.169 42.72 4.50 33.26 46.07 34.41 54.00
-19.59 AV Vertical 7386.215 61.01 5.02 37.78 45.77 58.04 74.00
-15.96 Pk Vertical 7386.215 44.42 5.02 37.78 45.77 41.45 54.00
-12.55 AV Vertical 4924.045 66.52 4.50 33.26 46.07 58.21 74.00
-15.79 Pk Horizontal 4924.045 46.70 4.50 33.26 46.07 38.39 54.00
-15.61 AV Horizontal 7386.132 61.41 5.02 37.78 45.77 58.44 74.00
-15.56 Pk Horizontal 7386.132 44.95 5.02 37.78 45.77 41.98 54.00
-12.02 AV Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.5.4.2 Band edge - radiated
- Page 26 of 47 -
Report No.: MTi190618E124 Note: (1) All Readings are Peak Value (VBW=3MHz) and AV Value (VBW=10Hz).
(2)Emission Level= Antenna Factor + Cable Loss + Read Level - Preamp Factor
(3) All other emissions more than 20dB below the limit. Frequency Meter Cable Antenna Preamp Emission Limits Margin Detector Comment Reading Loss Factor Factor Level
(MHz)
(dBV)
(dB) dB/m
(dB)
(dBV/m)
(dBV/m)
(dB) Type 802.11b 2310.00 56.33 2.40 27.70 40.40 46.03 2310.00 43.82 2.40 27.70 40.40 33.52 2310.00 58.34 2.40 27.70 40.40 48.04 2310.00 41.71 2.40 27.70 40.40 31.41 2390.00 57.64 2.44 28.30 40.10 48.28 2390.00 42.47 2.44 28.30 40.10 33.11 2390.00 57.20 2.44 28.30 40.10 47.84 2390.00 41.89 2.44 28.30 40.10 32.53 2483.50 57.93 2.48 28.70 39.80 49.31 2483.50 42.97 2.48 28.70 39.80 34.35 2483.50 59.00 2.48 28.70 39.80 50.38 2483.50 41.82 2.48 28.70 39.80 33.20 802.11g 2310.00 58.84 2.40 27.70 40.40 48.54 2310.00 44.54 2.40 27.70 40.40 34.24 2310.00 56.71 2.40 27.70 40.40 46.41 2310.00 43.20 2.40 27.70 40.40 32.90 2390.00 58.14 2.44 28.30 40.10 48.78 2390.00 42.00 2.44 28.30 40.10 32.64 2390.00 58.50 2.44 28.30 40.10 49.14 2390.00 44.20 2.44 28.30 40.10 34.84 2483.50 58.75 2.48 28.70 39.80 50.13 2483.50 43.80 2.48 28.70 39.80 35.18 2483.50 59.15 2.48 28.70 39.80 50.53 2483.50 41.70 2.48 28.70 39.80 33.08 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54
-27.97
-20.48
-25.96
-22.59
-25.72
-20.89
-26.16
-21.47
-24.69
-19.65
-23.62
-20.80
-25.46
-19.76
-27.59
-21.10
-25.22
-21.36
-24.86
-19.16
-23.87
-18.82
-23.47
-20.92 Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Horizontal Horizontal Vertical Vertical Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 27 of 47 -
Report No.: MTi190618E124 2310.00 57.95 2310.00 44.00 2310.00 58.89 2310.00 42.10 2390.00 58.02 2390.00 41.96 2390.00 57.10 2390.00 41.93 2483.50 58.13 2483.50 43.11 2483.50 59.23 2483.50 42.23 802.11n20 27.70 40.40 47.65 27.70 40.40 33.70 27.70 40.40 48.59 27.70 40.40 31.80 28.30 40.10 48.66 28.30 40.10 32.60 28.30 40.10 47.74 28.30 40.10 32.57 28.70 39.80 49.51 28.70 39.80 34.49 28.70 39.80 50.61 28.70 39.80 33.61 2.40 2.40 2.40 2.40 2.44 2.44 2.44 2.44 2.48 2.48 2.48 2.48 74 54 74 54 74 54 74 54 74 54 74 54
-26.35
-20.30
-25.41
-22.20
-25.34
-21.40
-26.26
-21.43
-24.49
-19.51
-23.39
-20.39 Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Horizontal Horizontal Vertical Vertical Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.5.4.3 Spurious Emission in Restricted Band 3260MHz-18000MHz All the modulation modes have been tested, and the worst result was report as below:
- Page 28 of 47 -
Report No.: MTi190618E124 Frequency Reading Cable Antenna Preamp Emission Limits Margin Detector Comment Level Loss Factor Factor Level
(MHz)
(dBV)
(dB) dB/m
(dB)
(dBV/m)
(dBV/m)
(dB) Type 3260 3260 3260 3260 3332 3332 3332 3332 60.95 3.27 30.02 38.05 56.19 52.64 3.27 30.02 38.05 47.88 61.34 3.27 30.02 38.05 56.58 52.61 3.27 30.02 38.05 47.85 64.59 3.31 30.00 37.91 59.99 52.52 3.31 30.00 37.91 47.92 62.94 3.31 30.00 37.91 58.34 52.93 3.31 30.00 37.91 48.33 17797 42.56 8.63 44.23 39.60 55.82 17797 33.12 8.63 44.23 39.60 46.38 17788 44.23 8.63 44.23 39.60 57.49 17788 31.93 8.63 44.23 39.60 45.19 74 54 74 54 74 54 74 54 74 54 74 54
-17.81
-6.12
-17.42
-6.15
-14.01
-6.08
-15.66
-5.67
-18.18
-7.62
-16.51
-8.81 Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 29 of 47 -
Report No.: MTi190618E124 5.6 Band edge - Conducted 5.6.1 Limits In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a) (see 15.205(c)). 5.6.2 Test setup 5.6.3 Test procedure a) Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. b) Position the EUT without connection to measurement instrument. Turn on the EUT and connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating range, and make sure the instrument is operated in its linear range. c) Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span including 100 kHz bandwidth from band edge. d) Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with marking the highest point and edge frequency. e) Repeat above procedures until all measured frequencies were complete. EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 30 of 47 -
Report No.: MTi190618E124 5.6.4 Test results Test plots:
802.11b: Band Edge, Left Side 802.11b: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 31 of 47 -
Report No.: MTi190618E124 802.11g: Band Edge, Left Side 802.11g: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 32 of 47 -
Report No.: MTi190618E124 802.11n20: Band Edge, Left Side 802.11n20: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 33 of 47 -
Report No.: MTi190618E124 5.7 6dB bandwidth 5.7.1 Limit FCC Part15 Subpart C Section Test Item Limit 15.247(a)(2) Bandwidth
>= 500KHz
(6dB bandwidth) Frequency Range
(MHz) Result 2400-2483.5 Pass 5.7.2 Test setup 5.7.3 Test procedure a. Set RBW= 100 kHz. b. Set the video bandwidth (VBW) 3 x RBW. c. Detector = Peak. d. Trace mode = max hold. e. Sweep = auto couple. f. Allow the trace to stabilize. g. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower) that are attenuated by 6 dB relative to the maximum level measured in the fundamental emission. EUT Operation Conditions The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.7.4 Test results
- Page 34 of 47 -
Report No.: MTi190618E124 EUT WiFi Mouser Model Name WFMZ1 Temperature 25 Relative Humidity 60%
Pressure 1012 hPa Test Voltage DC 6V from battery Test Mode TX b Mode /CH01, CH06, CH11 Channel Low Middle High Frequency 6dB bandwidth
(MHz)
(MHz) 2412 2437 2462 8.119 9.037 8.122 TX CH 01 Limit
(kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 35 of 47 -
Report No.: MTi190618E124 TX CH 06 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 36 of 47 -
Report No.: MTi190618E124 EUT WiFi Mouser Model Name WFMZ1 Temperature 25 Relative Humidity 60%
Pressure 1012 hPa Test Voltage DC 6V from battery Test Mode TX g Mode /CH01, CH06, CH11 Channel Low Middle High Frequency 6dB bandwidth
(MHz)
(MHz) 2412 2437 2462 16.30 16.37 16.37 TX CH 01 Limit
(kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 37 of 47 -
Report No.: MTi190618E124 TX CH 06 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 38 of 47 -
Report No.: MTi190618E124 EUT WiFi Mouser Model Name WFMZ1 Temperature 25 Relative Humidity 60%
Pressure 1012 hPa Test Voltage DC 6V from battery Test Mode TX n20 Mode /CH01, CH06, CH11 Channel Low Middle High Frequency 6dB bandwidth
(MHz)
(MHz) 2412 2437 2462 16.34 16.34 16.58 TX CH 01 Limit
(kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 39 of 47 -
Report No.: MTi190618E124 TX CH 06 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 40 of 47 -
Report No.: MTi190618E124 5.8 Duty Cycle 5.8.1 Conformance Limit No limit requirement. 5.8.2 Measuring Instruments The Measuring equipment is listed in the section 4 of this test report. 5.8.3 Test Setup 5.8.4 Test Procedure The zero-span mode on a spectrum analyzer or EMI receiver if the response time and spacing between bins on the sweep are sufficient to permit accurate measurements of the on and off times of the transmitted signal. Set the center frequency of the instrument to the center frequency of the transmission. Set RBW OBW if possible; otherwise, set RBW to the largest available value. Set VBW RBW. Set detector = peak or average. The zero-span measurement method shall not be used unless both RBW and VBW are > 50/T and the number of sweep points across duration T exceeds 100.
(For example, if VBW and/or RBW are limited to 3 MHz, then the zero-span method of measuring duty cycle shall not be used if T 16.7 microseconds.) The transmitter output is connected to the Spectrum Analyzer. We tested accroding to the zero-span measurement method, 6.0(b) in KDB 558074 The largest availble value of RBW is 8 MHz and VBW is 50 MHz. The zero-span method of measuring duty cycle shall not be used if T 6.25 microseconds. (50/6.25 = 8) The zero-span method was used because all measured T data are > 6.25 microseconds and both RBW and VBW are > 50/T. The RF output of EUT was connected to the spectrum analyzer by RF cable and attenuator. The path loss was compensated to the results for each measurement. Set to the maximum power setting and enable the EUT transmit continuously. The EUT was operating in controlled its channel. Use the following spectrum analyzer settings:
Span = Zero Span RBW = 8MHz (the largest available value) VBW = 8MHz ( RBW) Number of points in Sweep >100 Detector function = peak Trace = Clear write Measure Ttotal and Ton Calculate Duty Cycle = Ton / Ttotal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.8.5 Test Results
- Page 41 of 47 -
Report No.: MTi190618E124 EUT WiFi Mouser Model Name WFMZ1 Pressure 1012 hPa Test Voltage DC 6V from battery Test Mode TX b/g/n Mode / CH06 Mode Data rate Channel Ton Ttotal Duty Cycle 802.11b 1Mbps 802.11g 802.11n HT20 6Mbps MCS0 6 6 6
-
-
-
-
-
-
100%
100%
100%
Duty Cycle Factor
(dB) 0 0 0 VBW Setting 10Hz 1KHz 1KHz Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 42 of 47 -
Report No.: MTi190618E124 5.9 Spurious RF Conducted Emissions 5.9.1 Conformance Limit Below -20dB of the highest emission level in operating band. 5.9.2 Measuring Instruments The Measuring equipment is listed in the section 4 of this test report. 5.9.3 Test Setup 5.9.4 Test Procedure The Spurious RF conducted emissions compliance of RF radiated emission should be measured by following the guidance in ANSI C63.10-2013 with respect to maximizing the emission by rotating the EUT, measuring the emission while the EUT is situated in three orthogonal planes (if appropriate), adjusting the measurement antenna height and polarization etc. Set RBW=100kHz and VBW=
300KHz to measure the peak field strength, and measure frequency range from 9KHz to 26.5GHz. 5.9.5 Test Results Remark: The measurement frequency range is from 9KHz to the 10th harmonic of the fundamental frequency. The lowest, middle and highest channels are tested to verify the spurious emissions and band edge measurement data. Note1: The three modulated high, medium and low channels have been tested. The report only shows the worst mode. The worst mode is 802.11b CH01/06/11. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 43 of 47 -
Report No.: MTi190618E124 802.11b on Channel 01 802.11b on Channel 01
/
/
802.11b on Channel 01 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 44 of 47 -
Report No.: MTi190618E124 802.11b on Channel 06 802.11b on Channel 06
/
/
802.11b on Channel 06 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 45 of 47 -
Report No.: MTi190618E124 802.11b on Channel 11 802.11b on Channel 11
/
/
802.11b on Channel 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photographs of the Test Setup Radiated emission
- Page 46 of 47 -
Report No.: MTi190618E124 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photographs of the EUT See the APPENDIX 1: EUT PHOTO in the report No.: MTi190618E124-1.
- Page 47 of 47 -
Report No.: MTi190618E124
----END OF REPORT----
Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
1 | 17 AntSpec | Operational Description | 69.44 KiB | August 08 2019 |
Elexa Consumer Products, Inc. Declaration concerning Antenna Specification It is hereby declared that the product Model No.: WFMZ1 FCC ID: VII-WFMZ1 fulfills the requirement in FCC test relating to the antenna type. The device specified above confirms to the FCC recommendations for PCB Antenna antenna type(s) described below:
Model No. of antenna: N/A Type of antenna: permanently attached (i.e. soldered into the PCB / built into the housing) Gain of the antenna:
Frequency range:
1 dBi 2412~2462 MHz The mounting of the antenna is fixed to the radio module and no other antenna should beused. Company name: Elexa Consumer Products, Inc. Address:
City:
ZIP / Postal code: N/A Country:
United States 2275 Half Day Road, Suite 160, Bannockburn, IL60015, United States. Bannockburn Contact:
Shristi Sahu Date: 7/23/2019 Signature:
version01
1 | 18 RFExp r1 | RF Exposure Info | 178.81 KiB | August 08 2019 |
MPE REPORT FCC ID: VII-WFMZ1 Date of issue: June 19, 2019 Report Number:
MTi190618E125 Sample Description:
WiFi Mouser Mod el(s):
Applicant:
Address:
WFMZ1 Elexa Consumer Products, Inc. 2275 Half Day Road, Suite 160, Bannockburn, IL60015, United States. Date of Test:
May 31, 2019 to June 19, 2019 Shenzhen Microtest Co., Ltd. http://www.mtitest.com This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 2 of 4 -
Report No.: MTi190618E125 Applicants name:
Elexa Consumer Products, Inc. TEST RESULT CERTIFICATION Address:
2275 Half Day Road, Suite 160, Bannockburn, IL60015, United States. Manufacture's Name:
Elexa Consumer Products, Inc. Address:
Product name:
Trademark:
2275 Half Day Road, Suite 160, Bannockburn, IL60015, United States. WiFi Mouser Dome Model and/or type reference . : WFMZ1 Serial Model ...............................: N/A RF Exposure Procedures ....... : KDB 447498 D01 v06 This device described above has been tested by Shenzhen Microtest Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by:
Jone Lee June 19, 2019 Reviewed by:
Blue Zheng June 19, 2019 Approved by:
Smith Chen June 19, 2019 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 3 of 4 -
Report No.: MTi190618E125 RF EXPOSURE EVALUATION According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) MPE Calculation Method Friis transmission formula: Pd= (Pout*G)\ (4*pi*R2) Where Pd= Power density in mW/cm2 Pout=output power to antenna in mW G= Numeric gain of the antenna relative to isotropic antenna Pi=3.1415926 R= distance between observation point and center of the radiator in cm(20cm) Pd the limit of MPE, 1mW/cm2. If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Measurement Result
- Page 4 of 4 -
Report No.: MTi190618E125 WIFI:
Operation Frequency: WIFI 802.11b/g/n HT20: 2412-2462MHz, Power density limited: 1mW/ cm2 Antenna Type: Wifi Antenna: PCB Antenna;
WIFI antenna gain: 1dBi R=20cm mW=10^(dBm/10) antenna gain Numeric=10^(dBi/10)= 10^(1/10)=1.26 Channel Freq.
(MHz) modulation conducted power Tune-up power
(dBm)
(dBm) 2412 2437 2462 2412 2437 2462 2412 2437 2462 802.11b 802.11g 802.11n H20 Ant A 14.24 13.85 13.53 12.94 12.99 11.03 12.89 12.84 12.92 Ant A 141 141 141 121 121 121 91 91 91 Max Antenna Evaluation result at 20cm Power density Limits tune-up power Gain Power
(dBm) Ant A
(mW) Ant A Numeric Ant A 15 15 15 13 13 13 10 10 10 31.622777 31.622777 31.622777 19.952623 19.952623 19.952623 10 10 10 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 density(mW/cm2 )
(mW/cm2) Ant A 0.00793 0.00793 0.00793 0.00500 0.00500 0.00500 0.00251 0.00251 0.00251 1 1 1 1 1 1 1 1 1 Conclusion:
For the max result: 0.00793 1.0 for 1g SAR, No SAR is required.
----END OF REPORT----
Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-08-08 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-08-08
|
||||
1 | Applicant's complete, legal business name |
Elexa Consumer Products, Inc.
|
||||
1 | FCC Registration Number (FRN) |
0016722274
|
||||
1 | Physical Address |
2275 HALF DAY RD STE 160 STE 160
|
||||
1 |
2275 HALF DAY RD STE 160
|
|||||
1 |
Bannockburn, IL
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
j******@eurofins.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
VII
|
||||
1 | Equipment Product Code |
WFMZ1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
S****** S******
|
||||
1 | Title |
Project Manager
|
||||
1 | Telephone Number |
773-7********
|
||||
1 | Fax Number |
773-7********
|
||||
1 |
s******@elexausa.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | WiFi Mouser | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. This device supports 20MHz bandwidth operation only. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Microtest Co., Ltd.
|
||||
1 | Name |
S******** L******
|
||||
1 | Telephone Number |
0755-********
|
||||
1 |
S******@51mti.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 41 | 2412.00000000 | 2462.00000000 | 0.0266000 | ppm |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC