1 |
|
Exhibit 8 User Manual | Users Manual | 3.49 MiB | ||||
1 | ID Label/Location Info | |||||||
1 | RF Exposure Info | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Test Report | |||||||
1 | Internal Photos |
1 | Exhibit 8 User Manual | Users Manual | 3.49 MiB |
Technical Information Fieldgate FXA320, FXA520 Gateways / Interfaces Gateway for Remote Monitoring of Sensors and Actuators via Web Browsers Their integrated time control make Fieldgates suitable for all applications in which more distant measuring points have to be sporadically analysed. Configurable monitoring of limit values with alarm signalling via e-
mail or SMS make it possible to react directly to changes on-site. The supported data transfer in XML format allows for simple further analysis and processing of the measured data, through to integration into complex planning systems. Your benefits Communication via modem, Ethernet or GSM/GPRS Uses standard Internet protocols
(TCP/IP, http) Simple configuration with web browsers without additional software Visualisation via Internet/Intranet in the web browser and/or WAP mobile phone Limit value monitoring with alarm signalling via e-mail or SMS Synchronised time stamping of all measured values XML data transfer allows for simple further processing of the measured data FXA320 Optionally, four binary inputs with event counter function and frequency measurement Two 4...20 mA current inputs with integrated loop power supply Selectable active/passive current input (for 2-wire and 4-wire devices) Integrated communication resistor (250 ) for configuration via Commubox FXA520 Web server for remote monitoring of up to 30 measuring points Up to 4 measured values can be displayed per device
(HART) Intrinsically safe version [EEx ia]IIC for applications in hazardous areas Remote diagnosis and remote configuration of connected HART devices Applicable in 4...20 mA SIL 2 Loops (IEC 61508) Application Fieldgates enable remote monitoring of connected 4...20 mA sensors/actuators, either via telephone lines
(analogue), Ethernet TCP/IP or mobile communications
(GSM). The measured data is web compatible (HTTP, HTML, WML) and can, therefore, be analysed in the web browser without additional software. For remote diagnosis and remote configuration, HART sensors are suitable in conjunction with FXA520. TI369F/00/en Fieldgate FXA320, FXA520 Table of contents Applications. 3 Vendor Managed Inventory . 3 Remote maintenance of measuring equipment (FXA520 only) . 3 Ex-approval . 21 Explosion protection . 21 Other standards and guidelines . 21 Communication interface . 4 Internet connection . 4 Ethernet . 4 Telephone network (analogue) . 4 Mobile communications network (GSM) . 5 GPRS support . 5 Telecommunications Regulatory Compliance . 22 Fieldgate analogue version . 22 Fieldgate GSM version . 22
- Federal Communications Commissions Notice . 22
- Federal Communications Commissions Statement . 22
- Wireless Notices . 22 Ordering information. 23 Fieldgate FXA320 . 23 Fieldgate FXA520 . 23 Accessories . 24 Protective housing . 24 DAT module . 24 PC cable . 24 Telephone cable . 24 Fieldgate data access . 24 Fieldgate OPC server . 24 Java applets . 24 Antenna . 25 HART Client (FXA 520 only) . 25 Multiplexer (FXA 520 only) . 25 E+H power supply units (FXA 520 only) . 25 E+H Multidrop Connector FXN520 . 25 Solarbox . 25 Documentation . 26 Operating Instructions . 26 Certificates . 26 Accessories . 26 Function and system design. 6 Measuring system . 6 Input . 10 Analogue 4...20 mA inputs . 10 RS-485 interface (FXA 520 only) . 10 HART channel 1&2 (FXA 520 only) . 11 Binary inputs (FXA 320 only) . 11 Output . 11 Output signal . 11 Overvoltage category as per EN 61010 . 11 Protection class . 11 Power supply. 12 Electrical connection . 12 Supply voltage . 12 Power consumption . 12 Operating conditions: Installation . 13 Installation instructions . 13 Operating conditions: Environment. 14 Mounting location . 14 Permitted ambient temperatures . 14 Climatic and mechanic application class . 14 Ingress protection . 14 Electromagnetic compatibility (EMC) . 14 Application in protection functions . 14 Mechanical construction . 15 Design, dimensions . 15 Weight . 16 Materials . 16 Terminals . 16 Plug-in connections . 17 Human interface . 18 Display elements . 18 Operating elements . 18 Operation concept . 19 Certificates and approvals . 21 CE mark . 21 2 Endress + Hauser Fieldgate FXA320, FXA520 Vendor Managed Inventory Applications By using Fieldgates to interrogate tank or silo levels remotely, suppliers of raw materials can provide their regular customers with information about the current supplies at any time and, for example, account for them in their own production planning. For their part, the Fieldgates monitor the configured level limits and, if required, automatically activate the next supply. The spectrum of options here ranges from a simple purchasing requisition via e-mail through to fully automatic order administration by coupling XML data into the planning systems on both sides. Fieldgate FXA520 customer A 1...15 sensors 1...15 sensors supplier limit switches Fieldgate FXA320 Fieldgate FXA320 customer C customer B analogue 4...20 mA L00-FXA520xx-02-00-06-en-001 Remote maintenance of measuring equipment
(FXA520 only) Fieldgates not only transfer the current measured values, they also alert the responsible standby personnel, if required, via e-mail or SMS. In the event of an alarm or also when performing routine checks, service technicians can diagnose and configure connected HART devices remotely. All that is required for this is the corresponding HART operating software (e.g. ToF Tool - FieldTool Package, ReadWin, ...) for the connected device. Fieldgate passes on the information transparently, so that all options for the respective operating software are available remotely. Some on-site service operations can be avoided by using remote diagnosis and remote configuration and all others can at least be better planned and prepared. Fieldgate FXA520
- ToF Tool - FieldTool Package
- ReadWin
1...15 sensors 1...15 sensors L00-FXA520xx-02-00-06-en-002 Endress + Hauser 3 Fieldgate FXA320, FXA520 Communication interface Internet connection Ethernet If the Fieldgate dials into the Internet permanently via an Internet Service Provider, it is also possible for several users to access the Fieldgate simultaneously when using an analogue/GSM version. The other advantage is that the respective user does not require a modem as a receiver at the work place. The 10 Base T Ethernet interface with RJ45 plug-in connection can be connected to the local network using a hub or switch. A standard network cable is used for this. In Ethernet operation, you always have access to the Fieldgate with a standard web browser, since the device is constantly available in the network. Several PCs can access the Fieldgate simultaneously. Fieldgate FXA320 Fieldgate FXA520 RJ 45 RJ 45 RJ 45 RJ 45 Telephone network
(analogue) The Fieldgate is connected to the available telephone network via an RJ11 (PSTN) plug connector. This form of communication is always a point-to-point connection and only one PC can communicate with the device at any one time. In this configuration, the Fieldgate has to be selected before each access, so that it is ready for online operation. For example, the Windows internal telecommunications network can be used for dialling. After this, the Fieldgate can be accessed with a standard web browser (e.g. Internet Provider). The Fieldgate is also capable of dialling itself into a central server, in order to deliver periodic measured values for example. Here, it is also possible to transfer the measured values via the Internet using an Internet Service Provider. L00-FXA520xx-02-00-06-en-003 PSTN (Public Switched Telephone Network)
(e.g.. Telekom) Fieldgate FXA320 RJ 11 TAE Fieldgate FXA520 RJ 11 dial-up:
- data telecomminication connection
Web browser 4 L00-FXA520xx-02-00-06-en-004 Endress + Hauser Fieldgate FXA320, FXA520 Mobile communications network (GSM) If there is no Ethernet or telephone network available in the Fieldgate's operating location, the data can also be transferred via GSM using the mobile communications network. These communications versions can be configured as point-to-point connections or as freely accessible via the Internet/Intranet. A SIM card from a mobile communications network operator is required for GSM operation. Communication takes place via the data channel of the SIM card, which may require additional activation, depending on the GSM provider. PSTN (Public Switched Telephone Network)
(e.g. Telekom) Fieldgate FXA520 C SIM ard Fieldgate FXA320 C SIM ard GPRS support L00-FXA520xx-02-00-06-en-005 GPRS (General Packet Radio Services) is a mobile communications technique, which exploits the advantages of packet-oriented data transmission and channel bundling. Different from normal GSM connections, no complete channel is reserved for the duration of the connection between the mobile device and the basis station, rather the data is packed into packets, which can be sent depending on requirement and capacity. Data transmission in packets enables not only greater transmission rates but also always-on-operation. The Fieldgate is thus permanently in a position to connect to the Internet, an Intranet or a mailbox, whereby data is only transferred as required if a new e-mail is sent or a new Internet page is called up. Here, you are only charged for the amount of data actually transmitted (and not for connection time). The GPRS mode of the Fieldgate GSM thus offers the easiest and most cost-effective option for connecting a measuring point permanently to the Internet or an Intranet. Thanks to always-on-operation, the WAP functions of the Fieldgate can also be used easily and cost-effectively. To use the available GPRS functions, the GSM/GPRS provider will need to allocate a public IP address. It will be necessary to determine in each individual case, whether this additional service is offered by the respective operator. Endress + Hauser 5 Fieldgate FXA320, FXA520 Measuring system Function and system design Configuration with analogue input 4...20 mA (FXA320 only) Two devices can be connected directly. Selectable active/passive current input. Web browser HTTP script
(passive) 4...20 mA Loop-
Powered active passive Analogue Ethernet GSM Fieldgate FXA320 Fieldgate FXA320 T W H EN CIRCUIT 50 H 60 40 A L I V 70
KEE P TI G 20 30 E 80 90 100 K CF %
10 0 E R E LOSIVEATMOSPH IN E X P
(active) 4...20 mA 4-wire L00-FXA320xx-14-00-06-en-001 Configuration with binary input (FXA320 only) Four binary inputs with event counter function and frequency measurement. Two 4...20 mA current inputs. ToF Tool - FieldTool Package Commubox FXA191 Analogue Ethernet GSM Fieldgate FXA320 Web browser HTTP script 24 VDC L00-FXA320xx-14-00-06-en-002 6 Endress + Hauser Fieldgate FXA320, FXA520 HART - Point-to-Point configuration (FXA520 only) Two devices can be connected directly Can also be used in hazardous areas Qualified for 4...20 mA SIL 2 Loops (IEC 61508) Subsequent connection to available installation possible A HART communication resistor is already integrated into the device Additional connection of 4...20 mA sensors is also possible ToF Tool - FieldTool Package Commubox FXA191 e.g. 2 x RN221N-B ENDRESS+HAUSER RN 221N ENDRESS+HAUSER RN 221N Web browser HTTP script ToF Tool - FieldTool Package ToF Tool -
FieldTool Package e.g. RNS221 Commubox FXA191
. Analogue Ethernet GSM Fieldgate FXA520 Fieldgate FXA520
Configuration with analogue input 4...20 mA (FXA520 only) Two devices can be connected directly Can also be used in hazardous areas (e.g. RN221N) Subsequent connection to available installation possible L00-FXA520xx-14-00-06-en-007 Web browser HTTP script ToF Tool - FieldTool Package e.g. 2 x RN221N-A e.g. 2 x RN221N-B ENDRESS+HAUSER RN 221N ENDRESS+HAUSER RN 221N 4...20 mA
. Analogue Ethernet GSM Fieldgate FXA520 Fieldgate FXA520
ENDRESS+HAUSER RN 221N ENDRESS+HAUSER RN 221N 4...20 mA Endress + Hauser L00-FXA520xx-14-00-06-en-006 7 Fieldgate FXA320, FXA520 HART Multiplexer configuration (FXA520 only) Multiplexer, e.g. KFD2-HMM-16 from Pepperl Up to 30 devices (2 x 15) can be connected Subsequent connection to available installation possible 4...20 mA still possible Note!
Detailed information on the configuration can be found in the operating instructions BA 268F/00. Analog Ethernet GSM Fieldgate FXA520 Web browser ToF Tool - FieldTool Package HTTP script Master HART-Multiplexer e.g. Pepperl + Fuchs KFD2-HMM-16 RS 485 RS 485 Master HART-Multiplexer e.g. Pepperl + Fuchs KFD2-HMM-16 RNS221 maximum 15 devices
. maximum 15 devices L00-FXA520xx-14-00-06-en-005 8 Endress + Hauser Fieldgate FXA320, FXA520 HART - Multidrop configuration (FXA520 only) Only HART communication possible Up to 30 devices (2 x 15) can be connected When the maximum number of devices are connected, observe the following:
Minimum operating voltage of the connected devices, Voltage drop at the communication resistor, HART conformity multi-drop of the connected devices, Current consumption of the connected devices Output characteristics of the power supply unit All connected devices must first be allocated their own HART polling address A HART communication resistor is already integrated into the device. When the internal communication resistor is used, the permitted number of devices in multi-drop operation is reduced due to the limited current-carrying capacity of the resistor. Web browser ToF Tool - FieldTool Package HTTP script supply voltage 24 V Multidrop Connector FXN520 Analogue Ethernet GSM Fieldgate FXA520 channel 1 up to 15 devices channel 2 up to 15 devices device address: 15 03 02 01 L00-FXA520xx-14-00-06-en-003 All E+H measuring devices with the HART protocol can, therefore, be used to the full extent with the Fieldgate A current list of all E+H measuring devices that have the HART protocol can be found under:
www.hartcomm.org: "HART Products/Product Catalogue/ ...". All Endress+Hauser measuring devices with HART protocol can be connected to the Fieldgate. Even 4...20 mA devices without HART protocol can be operated in conjunction with the Fieldgate, e.g. limit switch (Liquiphant, ...). However, then only the measured value can be read. The remote maintenance function is not given for 4...20 mA devices because the HART protocol is required for this function. Endress + Hauser 9 Fieldgate FXA320, FXA520 Input Analogue 4...20 mA inputs FXA520 2 channels: joint ground of both channels, no galvanic isolation. Channel 1&2 - passive Max. input voltage per channel Max. input current per channel Input impedance Accuracy Voltage drop (incl. diode against reverse polarity) Connection cable Cable resistance 35 V 45 mA approx. 100 1 %
3 V Instrument cable, unscreened max. 25 per core FXA320 2 channels with galvanic isolation. Can be used independently as active or passive input. Channel 1&2 - active Output voltage No-load voltage Output current Short-circuit current short-circuit duration Connection cable Cable resistance Channel 1&2 - passive Max. input voltage per channel Max. input current per channel Input impedance Accuracy Voltage drop (incl. diode against reverse polarity) Connection cable Cable resistance 15 V 5% / (22 mA) 23.5 V 5%
max. 23 mA max. 64 mA Unlimited Instrument cable, unscreened max. 25 per core 35 V 45 mA 254 0.5 %
6.4 V Instrument cable, unscreened max. 25 per core RS-485 interface
(FXA 520 only) Galvanic isolation Termination resistor A-B 500 V RMS 120 fully integrated 10 Endress + Hauser Fieldgate FXA320, FXA520 HART channel 1&2
(FXA 520 only) The HART signal is capacitive coupled and decoupled via a communication resistor Communication resistor in the 4...20 mA signal line Integrated 270 communication resistor, for optional use, max. 45 mA!
Short-circuit duration (without interrior communication resistor) Unlimited Galvanic isolation between HART channel 1 and channel 2 Ex-isolation between field devices and internal circuits. Output voltage U0 in the event of a fault (Ex) Max. 6.5 V Max. current for EEx ia (Ex) Max. power output (Ex) Maximum input voltage (Ex) Maximum input voltage (non-Ex) 5.97 mA 39 mW 30 V 45 V Binary inputs (FXA 320 only) Galvanic isolation of all channels from the rest of the current circuits. Each 2 channels have the same reference potential. Number of digital inputs Input signal voltage Input current with H-signal Max. quiescent current with L-signal 4 L-signal: -3 ... +5 V H-signal: +15 ... +30 V 5 mA 1 mA Measuring range of event counter function 0 ...12.5 kHz Measuring range of frequency measurement 4.7 Hz (1%) ... 12.5 kHz (4%) Output Output signal A relay for alarm in the event of a fault Switching-off the sensor's power supply (in the event of a fault, power-save mode) Switching capacity of relay contacts:
U~ maximum 253 V I~ maximum 2 A P~ maximum 500 VA at cos 0.7 U- maximum 40 V I- maximum 2 A P- maximum 80 W Overvoltage category as per EN 61010 II Protection class II (double or reinforced insulation) Endress + Hauser 11 Electrical connection Fieldgate FXA320, FXA520 Power supply Terminal blocks The removable terminal blocks are isolated after intrinsically safe connections (on top of device) and non-
intrinsically safe connections (on bottom of device). Furthermore, the terminal blocks are also different in colour. Blue for the intrinsically safe area and grey for the non-intrinsically safe area. These distinctions allow for safe cable routing. Connecting the devices
(To the upper, blue terminal blocks). The two-core connecting wire between the Fieldgate FXA520 and HART devices can be a usual commercial instrument cable or cores in a multi-core cable for measuring purposes. If strong electromagnetic interferences have to be expected, e.g. from machines or radios, using a screened cable is recommended. Only connect the screening to the grounding connection in the device. The HART signal is decoupled passively without power supply. Operating the device in hazardous areas (FXA520 only) The national explosion protection directives for designing and routing the intrinsically safe signal cable must be observed. Maximum permitted values for capacity and inductivity can be found in the Safety Instructions of XA 188F. Connecting the supply voltage
(Terminal 1 and 2) For the voltage versions, see the Ordering information on page 23. A fuse is built into the power supply circuit so that a fine-wire fuse does not need to be connected in series. The Fieldgate is equipped with reverse polarity protection. Supply voltage Power consumption Alternating current version (AC):
Voltage range: 85...253 V, 50/60 Hz Safe galvanic isolation between mains power supply and internal circuits Direct current version (DC):
Voltage range: 20...60 VDC or 20 ... 30 VAC Reverse polarity protection guaranteed by bridge rectifier Safe galvanic isolation between mains power supply and internal circuits FXA520 Analogue Ethernet GSM Send mode Standby FXA320 Analogue Ethernet GSM Send mode Standby AC (at 253 VAC) DC (at 20 VDC) 6 VA 4.9 VA 8 VA 4.5 VA 2 W 1.5 W 4 W 1 W AC (at 253 VAC) DC (at 20 VDC) Solar (at 10 VDC) 8 VA 8 VA 8 VA 6 VA 3.5 W 3.5 W 4.8 W 2.9 W 4.6 W 2.8 W 12 Endress + Hauser Fieldgate FXA320, FXA520 Operating conditions: Installation Installation instructions Mounting location The Fieldgate must be placed in a cabinet, away from hazardous areas. There is also a protective housing (IP65) for two devices available for outdoor installation. EX EX min. IP 65 L00-FXA520xx-17-00-06-de-002 L00-FXA520xx-17-00-06-de-001 Orientation Vertical on DIN top-hat rail (HT 35 as per EN 60715). EN 60715; HT 35 x 7.5 EN 60715; HT 35 x 15 ANALOG FXA 520 L D Endress + Hauser 13 Fieldgate FXA320, FXA520 Operating conditions: Environment Mounting location Cabinet or protective housing Permitted ambient temperatures For individual mounting
-20 C... +60 C For series mounting without lateral spacing
-20 C... +50 C Storage temperature
-25 C... +85 C (preferably at +20 C) Installation in protective housing
-20 C... +40 C Maximum two Fieldgates can be installed into a protective housing. Caution!
The devices must be mounted such that they are protected from the weather and from impacts, and where possible in places that are not exposed to direct sunlight. This must be especially observed in regions with warm climates. Climatic and mechanic application class 3K3 In accordance with DIN EN 60721-3-3 3M2 In accordance with DIN EN 60721-3-3 Ingress protection IP 20, in accordance with EN 60529 Electromagnetic compatibility (EMC) Application in protection functions Interference Emission to EN 61326, Electrical Equipment Class B. The FXA 520 can be attached back effect freely to protection functions that are classified in SIL 2 to IEC 61508. SFF1 60%
1) SFF = Safe Failure Fraction TI1 1 year 5 years 2 PFDavg 1,23 x 10-6 6,13 x 10-6 10 years 1,23 x 10-5 1) 2) TI = Test Interval between life testing of the protection function (in years) PFDavg = Probability (average) of a dangerous Failure on Demand 14 Endress + Hauser Fieldgate FXA320, FXA520 Design, dimensions Mechanical construction Note!
100 mm = 3.94 in Housing: aligned housing (top-hat rail design) made of plastic Installation: on top-hat rail as per EN 60715; HT 35x7.5 or EN 60715; HT 35x15 Ingress protection as per EN 60529; IP 20 Min. 50 mm ANALOG FXA 520 L D ANALOG FXA 520 L D EX EX EX ANALOG FXA 520 L D Dimensions 45 mm 112 mm ANALOG FXA 520 L D Endress + Hauser m m 0 5
. i n M L00-FXA520xx-06-00-06-yy-002 m m 5 9 m m 8 0 1 L00-FXA520xx-06-00-00-de-001 15 Weight Materials Terminals approx. 250 g Housing Polycarbonate Colour: light grey, RAL 7035 Front cover Polyamide PA6 Colour: blue Fixing slide (for fastening on the top-hat rail) Polyamide PA6 Colour: black, RAL 9005 Connection cross-section maximum 1 x 2.5 mm or 2 x 1.5 mm Terminal assignment Fieldgate FXA320 1 1 2 1 3 1 4 1 789 0 1 ANALOG FXA 320 L D sensor 2
11 12 13 14 passive aktive sensor 1
7 8 9 10 passive aktive 12 5 1 6 1 2 2 3 2 4 2 6 2 7 2 8 2 L+ L-
N L1 15 16 1 2 supply relay Fieldgate FXA320, FXA520 binary inputs BI1 BI2 GND1 22 23 24 BI3 BI4 GND2 26 27 28 L00-FXA520xx-04-00-06-en-012 16 Endress + Hauser Fieldgate FXA320, FXA520 Terminal assignment Fieldgate FXA520 1 1 2 1 3 1 789 ANALOG FXA 520 L D 270
/ 0.55 W (communication resistor) CH 2 CH 1 11 12 13 7 8 9 HART HART channel 2 (EEx ia) and HART channel 1 (EEx ia) analogue input 4...20 mA CH1 CH2
23 24 21 22
4..20 mA 12 5 1 6 1 1 2 2 2 3 2 4 2 6 2 7 2 8 2 L+ L-
N L1 15 16 1 2 supply relay A B 26 27 28 RS-485 L00-FXA520xx-04-00-06-en-001 Plug-in connections Connection socket for Ethernet Fieldgate versions:
RJ45 socket Connection socket for GSM antenna:
FME socket (male) Connection plug for DAT module:
8-pin plug connector in 2.54 mm raster, 2 rows Connection plug for PC cable:
3-pin plug connector in 2.54 mm raster, 1 row Endress + Hauser 17 Fieldgate FXA320, FXA520 Human interface Display elements 9 CH 1 CH 2 4 5 1 2 3 6 7 8 L00-FXA320xx-07-00-06-xx-005 Position Light emitting diode (LED) Meaning 1 2 3 4 5 Green LED constant Displays the correct power supply Red LED constant Red LED flashes Yellow LED Yellow LED Yellow LED Displays a fault Displays a warning / On site communication via PC / Hardware is unlocked / system start Switching status of the built-in relay / LED on = relay tightens LED off = relay de-energised LED on = relay energised Displays a successful connection Displays a transfer activity / GSM version: field strength display if no connection Operating elements For the arrangement of the elements, see the diagram above. Position Element Meaning 6 7 8 Socket Button Socket Connection socket for DAT module Button for hardware security locking and configuration reset Connection socket for PC cable (service connector) FXA320 only Position Element Current input channel 1 (CH1) Current input channel 2 (CH2) 9 Switch position
(up) Switch position
(down) aktive passive aktive passive 18 Endress + Hauser Fieldgate FXA320, FXA520 Operation concept Fieldgate offers world-wide remote monitoring, remote diagnosis and remote configuration of Smart transmitters with the international used HART protocol. Measured values become available world-wide via Internet and can be efficiently processed. A standard web browser is used for visualising and remote inquiry. Fieldgate displays parameters and measured values of field instruments on an HTML page. Max. 30 measured values can be displayed. Up to 4 measured values can be displayed per device. Fieldgate FXA520 L00-FXAY2Kxx-20-13-00-en-301 L00-FXA520xx-20-13-00-en-167 19 Endress + Hauser Fieldgate FXA320, FXA520 Fieldgate FXA320 L00-FXA320xx-20-13-00-en-001 20 Endress + Hauser Fieldgate FXA320, FXA520 CE mark Ex-approval Explosion protection Certificates and approvals The Fieldgate meets the legal requirements of the EC directives. Endress+Hauser confirms that the device has been successfully tested by applying the CE label. FXA520 see Ordering information FXA520
[EEx ia] IIC Intrinsically safe circuits Values for each circuit:
Voltage Current Power Max. external values in accordance with the following table:
Inductance Lo [mH]
Uo = 6.5 VDC Io = 6 mA Po = 9.8 mW Capacitance Co [F]
Group IIC IIB 25 570 1000 1000 If inductances and capacitances are concentrated the following values apply:
Group Capacitance Co [F]
Inductance Lo [mH]
IIC IIB 2 2 1.5 10 10 7 0.5 1 5 1 2 5 Other standards and guidelines Other standards and guidelines that have been observed when designing and developing the Fieldgate. EN 60529 Ingress protections for housing (IP code) EN 61010 Safety requirements for electrical equipment for measurement, control and laboratory use EN 61326 Interference emission (class B operating equipment), interference immunity (appendix A - industrial sector) EN 60950 (IEC 950) Safety of information technology equipment Endress + Hauser 21 Fieldgate FXA320, FXA520 Telecommunications Regulatory Compliance Fieldgate analogue version North America FCC CFR 47, part 15 and part 68 Europe Telecoms Terminal Equipment Directive (98/13/EG) European approval TBR 21 Fieldgate GSM version North America FCC CFR 47 Part 15 and Part 24 Federal Communications Commission Notice This device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. To ensure that the unit complies with current FCC regulations and safety requirements limiting both maximum RF output power and human exposure to radio frequency radiation, use an antennna with a maximum gain of 2dBi and a separation distance of at least 20 cm must be maintained between the unit's antenna and the body of the user and any nearby persons at all times and in all applications and uses. Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Endress+Hauser may void the user's authority to operate the equipment. Federal Communications Commission Statement FCC-ID: LCG-FG-FXA52x-32x This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Wireless Notices In some situations or environments, the use of wireless devices may be restricted. Such restrictions may apply aboard airplanes, in vehicles, in hospitals, near explosives, in hazardous locations, etc. If you are uncertain of the policy that applies to the use of this device, please ask for authorization to use it prior to turning it on. 22 Endress + Hauser Fieldgate FXA320, FXA520 Fieldgate FXA320 Ordering information 10 20 30 40 50 Certificates A Version for non-hazardous areas F CSA, general purpose Y Special version Power supply A Power supply 85...253 VAC, 50/60 Hz E Power supply 20...60 VDC, 20...30 VAC G Solar panel connection 10...20 VDC Y Special version Ethernet - 10 Base T Modem interface 1 2 Analogue modem 4 GSM modem without antenna 9 Special version DAT module A without DAT module B with DAT module Y Special version Input A 2-channel analogue (4...20 mA) B 2-channel analogue (4...20 mA) + 4 binary FXA320-
Complete product designation Fieldgate FXA520 10 20 30 40 Certificates A Version for non-hazardous areas G ATEX II (1) GD P FM S CSA Y Special version EEx ia IIC T6 IS - Class I, II, III, Division 1, Group A-G IS - Class I, II, III, Division 1, Group A-G Power supply 20...60 V DC, 20...30 V AC Power supply E A Power supply 85...253 V AC, 50/60 Hz Y Special version Ethernet - 10 Base T Modem interface 1 2 Analogue modem 4 GSM modem without antenna 9 Special version DAT module A without DAT module B with DAT module Y Special version FXA520-
Complete product designation Note!
A PC cable is included in the scope of supply with FXA320/520. Endress + Hauser 23 Fieldgate FXA320, FXA520 Accessories Note!
The following table gives an overview of possible application for the individual accessory parts with the Fieldgate FXA320 or FXA520. Accessory Protective housing DAT module PC cable Fieldgate FXA320 Fieldgate FXA520 X X X X X X Telephone cable (analogue version only) is required is required Fieldgate data access Fieldgate OPC server Java applets Antenna (GSM version only) HART Client (FXA 520 only) Multiplexer (FXA 520 only) E+H power supply units (FXA 520 only) X X X X X X is required is required X X X Protective housing The protective housing in protection class IP 66 is equipped with an integrated top-hat rail and is closed with a transparent cover that can also be lead sealed. Dimensions:
W 180 / H 182 / D 165 Colour:
Light grey RAL 7035. Order number: 52010132. DAT module PC cable An external EEPROM, in which the configuration data is saved identically to the internal EEPROM, can be attached optionally via plug. For example, this allows for the FXA320/520 to be changed in the event of a defect, without losing the customer-specific configuration data. Order number: 52013311. A PC can be connected to the FXA320/520 for configuration purposes via a serial RS 232 connection. Order number: 52013984. Telephone cable RJ11 (analogue plug, double-sided, length: 5 m). Order number: 52014031. Fieldgate data access Fieldgate Data Access software assists with the collection of data from different Fieldgates. The fetching of data is controlled via entries in the Scheduler. Time control can be via periodic intervals or at user-defined times. Under Windows NT4 / 2000 / XP, collection of the data can accomplished via a "system service", which runs in the background. The data are saved in CSV format. Further processing of the data can be carried out with, e.g. Excel. Fieldgate OPC server The Fieldgate OPC server provides an interface between one or more Endress+Hauser Fieldgate devices and all possible OPC Data Access 2.0 compatible Clients. The Fieldgate can be connected via a dial-up modem or through a TCP/IP network. Java applets Java applets for a customised view of the screen. 24 Endress + Hauser Fieldgate FXA320, FXA520 Antenna Antenna for communication via mobile communications (GSM):
Triband flat antenna. Order number: 52018396. Dual band station antenna. Order number: 52018395. HART Client (FXA 520 only) The HART Client is a free add-on which is required for remote configuration via HARTtools (e.g. with ToF Tool - FieldTool Package, ReadWin, ...). You can download the current software version from the Internet from the Endress+Hauser product pages (download: http://www.endress.com). Multiplexer (FXA 520 only) Accessories for HART Multiplexer system (from Pepperl+Fuchs):
HART Multiplexer Master KFD2-HMM-16. Order number: 52017691. Master-interface connecting cable. Order number: 52017687. HART Multiplexer slave KFD0-HMS-16. Order number: 52020232. Master-slave connecting cable. Order number: 52020233. Interface module without communication resistor. Order number: 52017689. Interface module with communication resistor. Order number: 52017690. Switched-mode power supply. Order number: 52017688. E+H power supply units
(FXA 520 only) RMA422 Multifunctional 1-2-channel top-hat rail device with intrinsically safe current inputs and transmitter power supply, limit value monitoring, mathematics functions and 1-2 analogue outputs. RNS221 Power supply unit for supplying power to two two-wire sensors or transmitters in non-hazardous areas. RN221N Isolator with power supply for safely isolating 4...20 mA standard signal circuits. RMA421 Multifunctional 1-channel top-hat rail device with universal input, transmitter power supply, limit value monitoring and analogue output. E+H Multidrop Connector FXN520 Operated several devices in multi-drop operation for FXA520. Order number: 52023652. Solarbox Self-sufficient current supply unit for FXA320 with solar panel. Endress + Hauser 25 Fieldgate FXA320, FXA520 Documentation Operating Instructions KA 193F/00/a6 Mounting and installation instructions for Fieldgate FXA520. Order number: 52013633. KA 215F/00/a6 Mounting and installation instructions for Fieldgate FXA320. Order number: 52020867. BA 258F/00/en Operating Instructions for Fieldgate FXA520 (online help in the Internet browser). BA 282F/00/en Operating Instructions for Fieldgate FXA320 (online help in the Internet browser). BA 273F/00/en Operating instructions for Fieldgate Data Access software (download via the Internet). Ba 272F/00/en Operating instructions for Fieldgate OPC server software (download via the Internet). Certificates XA 188F-A/00/a3 Safety Instructions for electrical operating equipment for hazardous areas. Order number: 52013636. ZD 086F/00/en Control Drawings (FM). Order number: 52013634. ZD 087F/00/en Control Drawings (CSA). Order number: 52013635. Accessories BA 265F/00/de Cable for the HART Multiplexer-System. Order number: 52017693. BA 266F/00/en Interface Modul without Communication resistor. Order number: 52017694. BA 267F/00/de Interface Modul with Communication resistor. Order number: 52017695. BA 268F/00/en HART-Multiplexer Master KFD2-HMM-16. Order number: 52017696. BA 283F/00/en HART Multiplexer slave KFD0-HMS-16. Order number: 52021044. BA 269F/00/en Switched power supply. Order number: 52017698. TI 391F/00/en Solarbox for Fieldgate FXA320. Order number: 52023595. 26 Endress + Hauser Fieldgate FXA320, FXA520 Endress + Hauser 27 Fieldgate FXA320, FXA520 International Head Quarter Endress+Hauser GmbH+Co. KG Instruments International Colmarer Str. 6 79576 Weil am Rhein Deutschland Tel. +49 76 21 9 75 02 Fax +49 76 21 9 75 34 5 www.endress.com info@ii.endress.com TI369F/00/en/04.04 FM+SGML 6.0 ProMoDo
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2004-05-13 | 1850.2 ~ 1909.8 | PCB - PCS Licensed Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2004-05-13
|
||||
1 | Applicant's complete, legal business name |
Endress and Hauser GmbH and Co
|
||||
1 | FCC Registration Number (FRN) |
0010915122
|
||||
1 | Physical Address |
Hauptstrasse 1
|
||||
1 |
Maulburg, N/A D-79690
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
k******@cetecom.de
|
||||
1 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
LCG
|
||||
1 | Equipment Product Code |
FG-FXA52X-32X
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
R******** R********
|
||||
1 | Title |
R&D Radar Level Measurement
|
||||
1 | Telephone Number |
00497********
|
||||
1 | Fax Number |
00497********
|
||||
1 |
r******@pcm.endress.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Endress and Hauser GmbH and Co
|
||||
1 | Name |
C****** S********
|
||||
1 | Physical Address |
Hauptstrasse 1
|
||||
1 |
Maulburg, D-79690
|
|||||
1 |
Germany
|
|||||
1 |
C******@pcm.endress.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | PCB - PCS Licensed Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Fieldgate FXA52X/32X series with GSM Module | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is EIRP. This device contains GSM 900MHz and GSM 1800MHz functions that are not operational in U.S. Territories. This device is to be used only for mobile and fixed applications. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Antennas used for this device must not exceed 2 dBi gain for mobile and fixed operating configurations. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Cetecom ICT Services GmbH
|
||||
1 | Name |
R****** H********
|
||||
1 | Telephone Number |
49-68********
|
||||
1 | Fax Number |
49-68********
|
||||
1 |
r******@ict.cetecom.de
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 24E | 1850.20000000 | 1909.80000000 | 0.6000000 | 28.0000000000 Hz | 300KGXW |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC