APPLICANT:
Ericsson Radio System AB EXHIBIT 8 - COVER SHEET EXHIBIT Page 8 1 FCC ID NO. B5KKRC12110-11 Table of Contents Description Microbase RBS884M Explanation 2W TRX in RBS884 Base Station RBS884 Base Station Hardware Technical Description Description RBS 884 Line Interface Board Description 84 pages 1 page 36 pages 27 pages 24 pages Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 1(84) DQI STATUS: EXITED, NUMBER OF REMAINING MAJOR ERRORS PER PAGE: 1.4 (See REVIEW below.) DESCRIPTION MICROBASE RBS884M ABSTRACT This document describes the microbase provided by the RBS 884 platform. It describes mainly the hardware structure along with general performance. REVIEW See review protocol 116/177619/FCP103307, rev A. This document has not been inspected according to DQI. Rev C: Only updated parts and a few other samples in the document are inspected according to the DQI process. See Minutes of Meeting Item Id 1572. See Revision Information for updated parts. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 2 TABLE OF CONTENTS 1 2 2.1 3 4 5 6 7 8 9 10 11 12 12.1 12.2 12.3 13 13.1 13.2 13.3 13.4 13.5 13.6 14 15 16 16.1 16.2 16.3 16.4 16.5 16.6 16.7 16.8 16.9 16.10 16.11 16.12 Revision Information
. Introduction Definitions
. Feature . System structure
. Functional structure
. Control structure . Speech paths
. EMRPMdevice connection and CFU allocation Timing and syncronization . RF structure
. Internal alarms . Power supply and CID
. General
. AC/DC Power Supply . DC Power Supply
. EMC and grounding principles
. Definitions EMC zones
. Earth connection . Grounding principles . Intake point . Board magazine shield
. Environmental design
. Cabinet layout
. Units . General REMUX
. STRM . EMRPM
. TRX
. RFTL . MC . COMBFILT . CABCOMB
. Power splitter backplane . AC/DC DCCONN
. 5 6 7 10 12 14 15 17 18 23 25 27 28 28 28 30 32 32 32 33 34 36 37 38 39 42 42 42 45 47 48 48 49 49 51 51 51 51 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 3 16.13 16.14 16.15 17 17.1 17.2 17.3 17.4 18 18.1 18.2 18.3 19 20 20.1 20.2 20.3 20.4 20.5 20.6 20.7 20.8 20.9 20.10 20.11 20.12 21 21.1 21.2 21.3 21.4 21.5 22 22.1 22.2 22.3 22.4 22.5 22.6 22.7 23 24 25 Fan
. CONN . Blind front panel Connection of cabinets
. Forward RF (Transmit path) . Reverse RF (Receive path)
. Speech and control . Air Frame Syncronization . Connection of cabinets 882M/DM884M . Control path . RF paths . Speech path and clock information
. HW support for Traffic functions
. HW support for Standard O&M functions . Event log
. Device recovery
. Backup of CC/DCCH/SR/VER Test and monitoring outlets
. Base Station Test Interface (BSTI) . CSU functions
. Alarm on power failure . Voice line characteristics . Hot Repair . Bypass at power failure
. Basic Fault Handling and Indications . Limitations
. HW support for Optional O&M functions . RF testloop with RFTL
. External alarms
. Control outputs
. SW and HW information Power backup . Performance . Capacity . APZ limitations
. Channel separation . Restart after power down . Restart after link failure . Small system restart . Large system restart . Redundancy structure
. Certification . Acronyms and abbreviations
. 52 52 52 53 53 55 56 57 58 58 60 69 71 72 72 72 72 73 73 73 73 73 73 74 74 74 76 76 76 76 77 77 78 78 78 78 78 78 78 79 80 81 82 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 4 26 References
. 84 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 5 1 REVISION INFORMATION A > B:
* three cascaded BS > five
* MCalarms connected to different EMRPMports
* Primary>Main, Auxiliary>Primary or Extension
* Clarified Channel Function allocation in chapter 8 B > C:
Page 11, 3: Added that the base station can use DC power supply. Page 11,3: Added the last paragraph. Page 27, 11: Added "or DCCONN" in the figure. Page 2831, 12: Rewritten the section due to addition of DC power supply. Page 32, 13.1: Changed "The pico site.." to "The micro site...". Page 3941, 15: Added "or DCCONN + blind plate" in the rightmost position in the figures. Page 5152, 16.11: Added this section. Page 73, 20.7: Added the last paragraph in this section. Page 73, 20.9: Added DCCONN. Page 80, 23: Added "or DC". Page 82, 25: Added DCCONN and UPS in the abbreviations list. Page 84, 26: Added reference 12. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 6 2 INTRODUCTION The first implementation on the RBS 884 platform will be a microbase. The BS will be fully multimode, i.e. have all channel functions:
Digital traffic channel, DTC Digital verification, DVER
"Analog" contol channel, ACC Analog voice channel, AVC Signal strength receiver, SR Digital contol channel, DCCH The RBS884 platform utilizes building practice BYB 401 001. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 7 2.1 DEFINITIONS T1 connection:
The American standard for 1.544 Mbit PCM connection. Carries 24 independent 64 kbit channels (DS0:s) which are always numbered 124. E1 connection:
The European standard for 2.048 Mbit PCM connection. Carries 32 independent 64 kbit channels (DS0:s) which are always numbered 031. CLINK:
The general communication interface within the RBS 884 base station. A 2.048 Mbit interface carrying 32 independent 64 kbit channels (DS0:s) which are always numbered 031.
(See ref <1>) TLINK:
The CLINK as applied in the RBS884M and C. There are two versions: TTL or RS485 pseudobalanced. The RS485 one is in principle the same as CLINK, but added buffer units modify the specified characteristics slightly. DS1: (Digital Signal level 1, 1.544 kb/s) The metallic interface between a Carrier and a Customer installation. 4Wire interface of 1.544 Mbit/s. DS0: (Digital Signal level 0, 64 kb/s) One 64 kbit channel on a T1 connection. (Also used as the name for a 64 kbit channel on a CLINK.) EXT_AFS:
An Air Frame Syncronization signal used between cabinets and from an external air frame sync source. AFS:
10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 8 An Air Frame Syncronization signal used internally in micro base cabinets to syncronize TRX:s. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 9 Micro base cabinet (MBC):
One cabinet and its internal equipment, supporting one complete cell or a part of one cell. It can be a "Main"
or an "Auxiliary" cabinet. Micro base (MB):
One node in the network supporting one or more microcells. Consists of one or more MBC:s, placed at the same physical location. Radio Cabinet Group (RCG):
A group of transcievers/combiners connected to the same RFTL. Alarm:
An APT alarm in the MSC. Showed on an alarm display and printed on alarm printer, in the MSC. Fault signal:
A signal from the base station, indicating possible malfunction. Can sometimes initiate an Alarm. Internal alarm:
A signal within the MB that indicates a faulty unit. Sent from a unit without system communication to a unit with system communication, i.e. an EMRP or a device processor. An example is a signal from a fan or a Multicoupler. Will result in a fault signal. RBS884M:
Name for the small, low power version of the RBS884family. 884M is currently only supplied in an indoor version. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 10 3 FEATURE One microbase cabinet provides up to eight dualmode carriers of about 23 dBm/200 mW each, or 26 dBm/400mW if double duplex is utilized (minimum half of that). The power is defined at the antenna feeder connection. Up to three cabinets can be connected RFwise to the antenna system forming one RCG (one group of antennas), which is generally one cell. The output power in the RCG decreases by approximately 3 dB for each added cabinet. A cell can of course consist of more than one RCG. Up to 16 cabinets can be connected at the same MB. This is limited by the APZ limit of 32 EMs per EMG. The carriers are TDMA frame and slot syncronized in digital mode, within one microbase. There is a possibility to control the synchronisation externally, in order to synchronize several base station sites. A MBC also have place for two TRX:s that can work as SR and VER. A microbase can utilize duplexers in one or both Rx branches, in order to reduce the number of antennas, or use separate TX and RX filters. Each cabinet has a switch to set an unique cabinet identity, for fault reporting purposes. A microbase is connected to MSC via one or more T1/E1 connections. Microbases can be connected in a cascading arrangement in order to reduce transmission costs. The MB is also prepared to work as a "HUB" in a starnetwork configuration. In a cascading or HUB arrangement, each MB will become a separate EMG and has its own control DS0 on the T1/E1. In order to insert more than one control DS0 on the T1/E1, multiplexing equipment is required in the MSC. The product RBS884M is developed for indoor usage. An outdoor version, RBS884C, is equipped with a climatic shelter. The RBS884M is compatible with the RBS882M/DM in the sense that cabinets from the two families can be connected in the same cell and common T1/E1 transmission link, control link and antennas can be used. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 11 The microbase runs on either mains 115/230V, or 24V DC
(see 12.1.1). If AC/DC is used battery backup is not needed due to automatic restart after power recovery passby mode in dropinsert operation alarm for mains failure If backup is required, it can be provided by using an external Uninterruptable Power Supply (UPS). If DC power supply is used the last one of the three functions for AC/DC above (alarm for mains failure) is not valid. Battery backup is required to achieve a DC power failure alarm. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 12 4 SYSTEM STRUCTURE Direct MSC connection:
MSC uETCtu MUX tnu MB E1/
lk T1
tu MB
mj E1/
lk T1
tu MB
mj lk
t..
mj Up to five microbases can be connected in a cascading arrangement with eight carriers / MB, on one PCM connection. If less carriers are used per microbase, the number can be increased, but the PCM lines may then not have maximum Jitter & Wander. The connections can be either T1/DS1 or E1/G.703. See 155 18ANT 244 01 for more information on cascading!
Via RBS 884 macro base:
MSC lk
| RBS 884
uETCtu MUX tnu tu MB
Macro mj lk
t..
mj E1/
T1
k E1/
| T1 lk lk|
mwj mwwj|
lvk
|STC|
mj
lk
|STCtj|
mj
lk
|STCtj
mj
j
k E1/
| T1 lk lk|
mwj mwj|
lvk
|STC|
mj
lk
|STCtj
mj
j
In the above application the RBS 884 Macro base is used only for transit of the DS0:s used in the MB
(both speech and control DS0:s). The 884M is prepared to work as a "HUB" in a starnetwork configuration. This will thus require special equipment placed in the "FUTURE" board slot. A MB will always become one individual EMG. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 13 MB can be cosited RBS882m (indoor version) and RBS884M (one or several cabinets). There are restrictions on interconnection order and cascading, if all system properties shall be maintained. The multiplexing arrangement may be done in several ways, e.g. using the Group Switch to combine the time slots. This configuration is tested for RBS884M and C. The figures above only indicate one possibility. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 14 5 FUNCTIONAL STRUCTURE The structure follows the "Odysseus" split into functional entities:
lk lk lk lk
u TRA tu CRI tu TCB tu ANP t
mj mj mj mj
CRI can be seen as consisting of two parts:
lk
u CRI t
mj
. lk lk
| | Processor|
| Transm. t
| Switch
mj mj u Interface tu Pool The division is done to limit the impact of functional or capacity changes to few parts. The parts should also be able to to be combined in flexible ways, to create different applications. The base station depends on the AXE10 distributed operating system APZ, i.e. all EMRP SW and the MSCBS communication plus start/restart behaviour must comply with its rules. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 15 6 CONTROL STRUCTURE The standard APZ EMG concept is used, i.e. one PCM time slot is used for signalling per EMG. There is one EMRP bus master, STRM (Signal terminal Regional), and a number of EMRPs per EMG. The EMRPs control the devices via TLINKs. PCM primary| incoming
| E1/T1
PCM secondary|
j EXT_AFS |
in|
outu REMUX |
setup |
lk
t to other cabinets
|STRM
lvk Ctrl |
| DS0 |
EMRPB (backplane) tu twk mj
| REMUX |
tk
(of CTRL DS0)mwwj lv
| Internal |
| alarms
| EMRPM #2
| V24 Terminal
| connection
| (+BSTI +debugger)
| TLINK
| (TTL) mu lu
| lu EMRPM |..
| | lu
| | | lu
| | | | mj lvklvklvk :
j | m|T||T||T|
Internal|alarms |R||R||R| Additional devices
|X||X||X|
mwjmwjmwj
mvvv... E1/T1 to additional microbases lvk
lnk AFS to TRX:s The EMRPM front connector is one only, but it is subdivided into V.24: TW or BSTI debugger 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 16 Only TW is intended for customer use, the other ones are not presented in customer documentation. Use of the debugger requires a special cable, i.e. not the one delivered to customers. The figure above indicates that all devices connect via TLINK. However, there are two versions of TLINK, balanced (EIA RS485) or unbalanced (TTL). See ref. 8!
The TTL version is used inside the cabinet and the RS485 version between cabinets. ALM and RFTL sense a pin in the backplane to determine mode CLINK/TLINK. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 17 7 SPEECH PATHS
| E1/T1 PCM primary|
PCM
secondary|
j E1/T1/DS1 TLINK to "FUTURE"
TLINK TLINK 4 TLINK:s to EMRPMs in further cabinets (RS485) lvk t
t
| REMUX |
t
tk tk
mwj
| TLINK
lvk lvk
lu lu
| lu EMRPM 1|
| lu EMRPM 2|
| | lu
| | lu
| | | lu
| | | lu
(TTL)| | | | |
| | | | mj
| | | | mj lvklvklvklvk lvklvklvklvk
|T||T||T||T|
|T||T||T||T|
|R||R||R||R|
|R||R||R||R|
|X||X||X||X|
|X||X||X||X|
mjmjmjmj mjmjmjmj TLINK The TLINK to the "FUTURE" slot is intended for a possible "hub" configuration, where several PCM lines extend from the hub site. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 18 8 EMRPMDEVICE CONNECTION AND CFU ALLOCATION Magazine, layout in principle lwwwwwwwwwwwwwwwwwk
|R |S |E |E |T |T |T |T |T |T |T |T |T |T |R |M |F | A
|E |T |M |M |R |R |R |R |R |R |R |R |R |R |F |C |U | C
|M |R |R |R |X |X |X |X |X |X |X |X |X |X |T |A |T | D
|U |M |P |P | | | | | | | | | | |L |/ |U | C
|X | |M |M |A |A |A |A |A |A |A |A | | | |M |R |
| | |# |# |C |V |V |V |V |V |V |V | | | |C |E |
| | |1 |2 |C |C |C |C |C |C |C |C |L |V | |B |/ |
| | | | |/ |/ |/ |/ |/ |/ |/ |/ |O |E | | |A |
| | | | |D |D |D |D |D |D |D |D |C |R | | |L |
| | | | |C |T |T |T |T |T |T |T | | | | |M |
| | | | |C |C |C |C |C |C |C |C | | | | | |
| | | | |H | | | | | | | | | | | | |
Position# | 1| 2| 3| 4| 5| 6| 7| 8| 9|10|11|12|13|14|15|16|17| 18 |
mvvvvvvvvvvvvvvvvvj TLINK:s from EMRPM #1 :
TLINK #1 TLINK #2 TLINK #3 to position #5 to position #6 to position #7 TLINK #4 to position #8
(TRX CC/DCCH + 2 DTC)
(TRX AVC/3 DTC/DCCH + 2 DTC)
(TRX AVC/3 DTC/CCR/SRR, if single cabinet is used)
(TRX AVC/3 DTC/DCCR +
2DTC/VERR, if single cabinet is used) TLINK #10 to position #1 TLINK #9 TLINK #7 TLINK #8
(Note: / above means exclusive or)
(REMUX) to position #15 (RFTL) to position #17 (ALM)
to position #17 (Future) *
TLINK:s from EMRPM #2 :
TLINK #1 TLINK #2 TLINK #3 TLINK #4 TLINK #5 TLINK #6
(TRX AVC/3 DTC/sec.DCCH+2DTC) to position #9 to position #10 (TRX AVC/3 DTC) to position #11 (TRX AVC/3 DTC) to position #12 (TRX AVC/3 DTC) to position #13 (TRX SR or SRR) to position #14 (TRX VER or VERR)
* Note that position #17 hosts two TLINK connections for control. This makes it possible to insert either an ALM board or any device developed in the future. Pos #17 also has a TLINK connection for speech for future "HUB" application or similar.
"Sec. DCCH" means second DCCH, if more than one is used per cell. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 19 The channel allocation to EMRPMs and TRXes are not the only ones possible, but the recommended ones due to redundancy and load. The document 15518ANT24401 states the application rules. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 20 Graphical presentation of the device allocation:
10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 21 Main Cabinet:
Time Slot 130 FUTURE board 14, 2:rd cab. 14, 2:nd cab. 14, 3:rd cab. 14, 3:nd cab.
| MSC / 884 BS / 884M |
mwj
| T1/E1
lk
|STRM t EMRPB lvk Ctrl |
| DS0 |
EMRPB twk tu
mj
| Speech+control lj
Ttnn
| REMUX | Speech
Btnn
Btnn Btnn
Btnn
Ttnk mk
Ttk
TS14 |
mwj
TS14 |
lj
mk
j T1/E1 2 T 5 T 3 T 2 T
10| |1 T | |T lvvk lvvk
EMRPM #2 (pos4) |
EMRPM #1
(pos3)
|1 10|
3 .. 6 4 6 .. 9 9 7 8
|T T |
T T T T T T T T mwwwwwwwwj mwwwwwj
lvk lvklvklvklvk lvklvk lvklvklvklvk
|T||T||T||T|
|A||F||R||R| |T||T|
|T|
|R||R||R||R|
|L||U||F||E| |R||R|
|R|
|X||X||X||X|
|M||T||T||M| |X||X|
|X|
|/||U||L||U| | || |
|F||R|| ||X| | || |
|U||E|| || | | || |
|T|| || || | | || |
|1|
|1||1||1||1| |9||1|
pos.|5||6||7||8|
|7||7||5|| | | ||0|
|4|
mjmjmjmj mjmjmjmj mjmj mj B = TLINK interface, RS485 T = TLINK interface, TTL C = CLINK interface, RS485 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 22 Auxiliary cabinet:
Main cabinet
| | CLINK
lk
| REMUX
mwwwj STRM
lnnk
| | | mj
lvvvk
| . C C
| . CONN
| Speech
| . nwk
| . Ttnk
| . Ttk
TS14 |
mwj
TS14 |
EMRPB
lj mk
2 T 9 T 6 T 3 T 2 T 3 .. T EMRPM #2 EMRPM #1 5 T
10| |1 T | |T
lvvk lvvk
to 10|
further |1 6 .. 9 4 7 8 cabinets |T T |
T T T T T mwwwwwwwwj mwwwwwj
lvklvklvklvk lvklvklvklvk lvklvk lvk
|T|
|A||F||R||R| |T||T|
|T||T||T||T|
|R|
|L||U||F||E| |R||R|
|R||R||R||R|
|X||X||X||X|
|M||T||T||M| |X||X|
|X|
|/||U||L||U| | || |
|F||R|| ||X| | || |
|U||E|| || | | || |
|T|| || || | | || |
pos.|5||6||7||8|
|1||1||1||1| |9||1|
|1|
|4|
|7||7||5|| | | ||0|
mjmjmjmj mjmjmjmj mjmj mj 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 23 9 TIMING AND SYNCRONIZATION Block diagram:
REMUX
lj EXT_AFS2|
EXT_AFS1|
lk
onk
select|
EXT_AFS1|
| AFS1 lk lvk
| |Sel. |
onuDettu twno tuExt tnwno onu
| | Int | | |
mj mwj | |
onnj |
onnj
| AFS2
|8 kHz sync EXT_AFS2|
lno
|2 MHz clock
| lk | lk
| |Line| | | PLL |
tno
onuSynctnuwith tvj
| | |OCXO |
8 kHz | mj | mj
onj
mj onk mk
Ext. air frame sync in Ext. air frame sync out PCM primary PCM secondary Air frame sync to TRX:s To devices via EMRPS:s Air frame sync information is carried over two 1620 kHz signals, containing phase information. External/internal air frame sync is selected in connector for external reference. In "External" mode the REMUX is supervising that the sync information is present, else a minor fault is generated. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 24 PLL
Data/clock w|
Data lk
| Buffer |
mj Expansion of Line sync and PLL with OCXO:
Datalk
t|
l| register|k
lk | Line
| | clock
| TSW |
tu
mj |
lk
|u t|
| Register|
lj lj
Data|
Data/clock nu
|nu
mv
mj
mk mk
m| OCXO lk
tv stable clock to
devices and AFS
mj 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked 10 RF STRUCTURE Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 25 Hybridcombiner
RF backplane
with power splitter lk mnj
| lk lk
| A muMCUtu mwj | MC tu
| B mnj |
tu
| lvk |
muMCUtu
mwwj mj
mj
|mu
mu lk tuTRX 1 |
tu mj
lk tuTRX 8 |
tu
mj
lk tuTRX 9 |
tu
mj
lk tuTRX 10|
tu
lk
tu mnj
tuMCUtj
tu
mj
lk mwwj
tj|
tj mj (SR)
| (VER) lk
| RFTL |
mj
* = is the same unit if TX/RX antenna duplexer is used. The picture shows the RFstructure for one cabinet. Up to three cabinets can be connected in the same cell Transmit, receive and duplex filters are not shown in this picture. The ANP can be configured for 1 duplex TX/RX, 2 duplex TX/RX, 1TX + 1RX or 2TX + 1RX antenna. The "double duplex" configuration increases output power by 3 dB compared to a single 8channel Hybrid combiner. The 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 26 configuration with separate TX and RX antennas are primarily useful for operators that use both A and Bband. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked 11 INTERNAL ALARMS Backplane:
Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 27 Front:
FAN lk
mj lk tk tk |
| | (One cable)
MC B MC A alarm from PSU eq.
| AC/DC or
| DCCONN
o int. |
mj lk
mj lu..............tj | FAN alarms bypassed by
| lu..............tj AC/DC to backplane
| | ln.........oon... Possible mains interrupt
| | | ln int.
| | | | lu
| | | | | lu
| | | | | mu#1
| | | | mu#2
| | | mu#3
| | mu#4
lk
lvk |
| mu#1 mu#2
tj mj lk lvk |
EMRPM:s | |
tj mj TRX:s The two EMRPM:s collect internal alarms from the AC/DC converter and the Multicoupler. Port #1: MC A Port #2: MC B Port #3: AC/DC converter failure Port #4: Mains interrupt The TRX:s collects the internal alarms from the two fans. Port #1: FAN #1 Port #2: FAN #2 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 28 12 POWER SUPPLY AND CID 12.1 GENERAL There is no power switch. At AC power supply the mains cord can be pulled out instead. This is not possible with DC power supply. The power consumption is found in ref [12]. 12.1.1 Definitions The usual denomination for the DC voltage is "24V DC". The actual voltage level is though approximately 27V DC. 12.2 AC/DC POWER SUPPLY The power supply is split between the CRIparts and other equipment. This is to create a holdup for the CRI, so that it is capable of sending a last signal to indicate loss of mains. The purpose is to avoid unnecessary maintenance calls, due to power disturbancies. A relay turns off the "TRX load" when an interruption is detected. The AC/DC can be strapped to either provide holdup of CRI 700ms, but disconnect the TRXes after 1620ms, or to keep the whole base station going for approx. 70ms, but then the mains failure alarm will not work. If power backup is required, it can be provided by an external UPS. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 29 lk MainstFuseu
|Rectifier|
120/230V lu
| mwwj
| lvk |
| |relay| |
m|
mwj |
t|
AC/DC lk
lk |
| CID | |
mwj |
/ N
mnwwj
|CID
|+24V|+24V
lk
t|
t.|.|REMUX | 1
t.|.|
mj
lk
t.|.|STRM | 1
t.|.|(CONN)|
mj
lk
t|
t.|.|EMRPM | 2
m.|.|
mj
lk
t|
|TRX
| 10
t.|.|
mj
lk
|FAN
| 1 t.|.|
mj
lk
t|
t.|.|RFTL | 1 t.|.|
mj
lk
m|ALM/ |
t|FUTURE| 1
m|
mj Figure 12.1 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 30 12.3 DC POWER SUPPLY At the DCCONN there is an input fuse. The DCCONN also includes transient protection and an EMC filter. There are two DC power alarms. To achieve both these alarms a battery backup is required. The first is activated when the voltage decreases to be less than 25.0 V, and deactivated again when the voltage exceeds 25.5 V . This alarm indicates that the normal power supply is decreasing and the backup power is activated. The other power alarm is activated when the voltage decreases to be less than 22.5 V, and deactivated again when the power exceeds 23.0 V, and indicates that the normal power supply is still not working and also the backup is being discharged. This is a serious fault and the TRXs shall be disconnected. There is a double DIPswitch on the DCCONN (not on the front) to disable the power alarms (disabled when "ON"). 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 31 lk DC Input tFuseu
| Filters |
mwwj
t|
|+24V|+24V
lk
|j
mj DCCONN lk
lk |
| CID | |
mwj |
/ N
mwwwj
|CID
lk
t|
t.|.|REMUX | 1 t.|.|
mj
lk
t.|.|STRM | 1 t.|.|(CONN)|
mj
lk
t|
t.|.|EMRPM | 2 t.|.|
mj lk
t|
|TRX
| 10 t.|.|
mj
t|
t.|.|RFTL | 1 t.|.|
t|FUTURE| 1 m|
lk
mj lk
m|ALM/ |
mj 1 |FAN Figure 12.2 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 32 13 EMC AND GROUNDING PRINCIPLES This section describes how the grounding is done in the RBS884M and 884C. In this section the word "ground" is used for a local ground structure, and "earth" is used for connection to Mother Earth. Note that all grounds are interconnected DCwise, so the installation should be made to avoid ground loops. See 3/1531ANT24401! The following grounds are interconnected:
AC protective ground chassis signal ground to TW/BSTI, REMUX local connection, CLINK/TLINK between cabinets shields for PCMlines, CLINK, EMRPB RF shields to antennas and between cabinets The cabinets are assumed to be placed close, "all in one room", except when connected via E1/T1interfaces. In that case there should not be any ground connection via shield. Note that this is valid also when cositing with RBS882M/DM. 13.1 DEFINITIONS RBS884M:
The micro site is intended for indoor use and consists of a cabinet (MBC) in which a fan unit, a board magazine and a filter shelf is installed. RBS884C:
The outdoor base station consists of the environmental shelter which contains the MBC, AC/DCconverters, climatic control unit, heater and air condition unit. The board rack contains the units that is the functional part of the base station. Outside the base station is antenna and (eventually) earth rod. Connections to the base station are AC mains, PCMlink, antenna cable and ground cable. 13.2 EMC ZONES To describe the EMC concept a division into different zones is useful. Each zone has it own EMC characterization, as follow:
Zone 0 is the surrounding of the base station. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 33 Zone 1: Transients from zone 0 are attenuated. Suitable to contain electronic devices with low radiation and low susceptibility. The ground characteristics of zone 1 is that it is equipotential, which means that every part of the ground in zone 1 has the same potential to earth (zone 0) in every moment. This is the base for protection against external transients and ESD. The ground structure shall be made to encircle the base station, e.g. by being a part of the enclosure. This creates a "wire shield", which is useful for protection against the fields connected to transients and conducted lightning. This concept is described for the macro base in ref 3. In RBS 884M the interior of the cabinet is zone 1, and for RBS 884C the interior of the climatic shelter is zone 1. Zone 2: Shielded from zone 1, and cables are filtered when passing the shield. The interior of zone 2 is equipotential and the shield is a part of the ground structure. The shield must be bonded to the ground structure in zone 1. Zone 2 is intended to contain unshielded electronic digital devices. These has medium emission and medium suscepitbility. Zone 3: Shielded from zone 1 and 2, and cables are filtered when passing the shield. Zone 3 is intended to contain radio equipment. Zone 3 contains circuits with high emission levels or high susceptibility, which means radio units. 13.3 EARTH CONNECTION 884M:
The base station has no separate earth connection. Earth connections is aceived via the earthing of the antenna cable shields and via the protective earth cable. The latter is sufficient for dissipating ESD charges.
(Note: It is not clear at the moment if there will be an earth connetion available for indoor MBS. This have an influence on the choise of transient protection devices and is under investigation.) 884C:
10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 34 To divert the energy from transients, lightning strokes and ESD an earth rod or similar is most likely needed. The protective earth wire in the AC mains is only suficent for dissipating ESD charges. A resistans to earth of max 10 ohms is a common value. The physical implementation will be decided together with AO. 13.4 GROUNDING PRINCIPLES 13.4.1 External connections and shields:
All cable shields must be terminated at the intake point. All external leads must have transient protection devices mounted close to the intake point (The center lead of the antenna cables are excluded). If the transient protection devices require connection to ground this shall be done at the intake point.
(NOTE: RBS 884M do dot at the moment have an intake point. If this not is possible to define, other solutins must me used.) 13.4.2 Cabinet interconnection:
All parts within the cabinet shall be grounded together. This shall preferably be done with metallic contact of the structures (called direct bond). If this is not possible, a short braided strap may be used. (Indirect bond). 13.4.3 Board magazine:
Inside the board magazine is multipoint ground used, and the ground planes of the boards are usually connected to both front and backplane. This is permitted but not required. The board magazine is designed according to BYB 401 001 and is covered by a shield. This shield is a part of the ground structure of the board magazine. The shield is grounded to the cabinet. 13.4.4 Fan unit:
The fan unit is grounded to the cabinet. This is required because of the RFfilters in the unit, and to reduce possible emission from the unit. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 35 13.4.5 Filter shelf:
The filter shelf is not grounded to the cabinet but to the antenna cable shield earthing. This is under investigation and must eventually be changed because of the paths for transient currents. See also under intake point. 13.4.6 AC/DC converter (only RBS 884C):
Grounded to the climatic shelter. Secondary transient protection devices in the unit. 13.4.7 Heater (only RBS 884C):
Grounding may be requiremd by safety reasons. No EMC requirement. 13.4.8 Control unit (only RBS 884C:
Grounded to the environmental protection. The interior is zone 1 or 2 depending on content. The zone definition gives the requirements on shielding and fitering. 13.4.9 Air condition unit (ACU) (only RBS 884C):
Is an extended part of zone 1. Cables between the ACU and the rest of the base station must not leave zone 1. The ACU must be grounded to the environmental cover. 13.4.10 884C:
13.4.10.1 External connections and shields:
All cable shields must be terminated at the intake point. All external leads must have transient protection devices mounted close to the intake point (The center lead of the antenna cables are excluded). If the transient protection devices require connection to ground this shall be done at the intake point. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 36 13.4.10.2 Cabinet interconnection:
All parts within the cabinet shall be grounded together. This shall preferably be done with metallic contact of the structures (called direct bond). If this is not possible, a short braided strap may be used. (Indirect bond). 13.4.10.3 Board magazine:
Inside the board magazine is multipoint ground used, and the ground planes of the boards are usually connected to both front and backplane. This is permitted but not required. The board magazine is designed according to BYB 401 001 and is covered by a shield. This shield is a part of the ground structure of the board magazine. The shield is grounded to the cabinet. 13.4.10.4 Fan unit:
The fan unit is grounded to the cabinet. This is required because of the RFfilters in the unit, and to reduce possible emission from the unit. 13.4.10.5 Filter shelf:
The filter shelf is not grounded to the cabinet but to the antenna cable shield earthing. This is under investigation and must eventually be changed because of the paths for transient currents. See also under intake point. 13.5 INTAKE POINT 884M:
The base station has no defined intake point. This will be evaluated and most likely changed, as it might cause malfunction because of transients and earth currents between protecitve earth and the antenna cable shield earth. 884C:
The most important part of the ligthning and transient protection is an intake point. This is a small area ( a few dm2) where all cables enter the base station. At this place shall all shields and ground cables
(including protective earth) be terminated, and all other cables shall have primary transient protection devices. Without this the equipotential in zone 1 is ruined. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 37 13.6 BOARD MAGAZINE SHIELD RBS 884C and RBS 884M:
The board rack will be surrounded of a shield with the primary function of reducing radiated emission to permitted levels. This shield shall have low impedance and be a part or the ground within the boardrack, zone 2. The shield must be connected to the ground in zone 1. Every cable that enter through the shield must be sufficient filtered. This is described in ref 4. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 38 14 ENVIRONMENTAL DESIGN There are two environment specs, describing the cabinetexternal requirements and the cabinetinternal requirements. The last is written to enable HW unit reuse without "reverse engineering" to find out what the different applications need. ref. 6 and 7, 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 39 15 CABINET LAYOUT Main cabinet:
Traffic capacity:
1 Analog control channel carrier 7 carriers for speech, dual mode, and digital CC 1 signal strength receiver 1 digital/analog verification receiver FAN lk
twwwwwwwwwwwwwwwwwu
|R |S|E|E|T|T|T|T|T|T|T|T|T|T|R |M |F | AC/ |
|E |T|M|M|R|R|R|R|R|R|R|R|R|R|F |C |U | DC
|M |R|R|R|X|X|X|X|X|X|X|X|X|X|T |A |T |
|U |M|P|P| | | | | | | | | | |L |/ |U | or |
|X | |M|M| |A|A|A|A|A|A|A| | | |M |R |
| | |/|/| |V|V|V|V|V|V|V| | | |C |E | DC |
| | |1|2|C|C|C|C|C|C|C|C|S|V| |B |/ | CONN |
| | | | |C|/|/|/|/|/|/|/|R|E| | |A | +
| | | | | |D|D|D|D|D|D|D| |R| | |L | blind|
| | | | | |V|V|V|V|V|V|V| | | | |M | plate|
| | | | | |C|C|C|C|C|C|C| | | | | |
|12|8|8|8|8|8|8|8|8|8|8|8|8|8|10|10|10| 22 | = 168 tvvvvvvvvvvvvvvvvvwu
|CAB |
|COMB |
mvj Filter, MCU & hybrid comb. COMBFILT The cabinet is possible to mount in a 19" rack directly. A front door is covering front cabeling. The cabinet combiner (CABCOMB) is only used if more than one cabinet is connected to the same cell. The TRX providing ACC can be configured to provide 1 DCCH and 2 DTC:s when DCCH is available. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 40 Auxiliary cabinets to increase no. of channels for one cell (sometimes called Extension):
Traffic capacity:
8 carriers for speech, dual mode (DCCH or ACC possible) 1 signal strength receiver (possible) 1 digital/analog verification receiver (possible) FAN lk
twwwwwwwwwwwwwwwwwu
|B |C|E|E|T|T|T|T|T|T|T|T|T|T|B |M |F | AC/ |
|l |O|M|M|R|R|R|R|R|R|R|R|R|R|l |C |U | DC
|i |N|R|R|X|X|X|X|X|X|X|X|X|X|i |A |T |
|n |N|P|P| | | | | | | | | | |n |/ |U | or |
|d | |M|M| |A|A|A|A|A|A|A| | |d |M |R |
| | |/|/| |V|V|V|V|V|V|V| | | |C |E | DC |
| | |1|2|C|C|C|C|C|C|C|C|S|V| |B |/ | CONN |
| | | | |C|/|/|/|/|/|/|/|R|E| | |A | +
| | | | | |D|D|D|D|D|D|D| |R| | |L | blind|
| | | | | |V|V|V|V|V|V|V| | | | |M | plate|
| | | | | |C|C|C|C|C|C|C| | | | | |
|12|8|8|8|8|8|8|8|8|8|8|8|8|8|10|10|10| 22 | = 168 tvvvvvvvvvvvvvvvvvwu
mvj Hybrid comb COMBFILT 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 41 Auxiliary cabinets to increase no. of cells connected to one EMG (sometimes called Primary):
Traffic capacity:
1 Analog control channel carrier 7 carriers for speech, dual mode, and digital CC 1 signal strength receiver 1 digital/analog verification receiver FAN lk
twwwwwwwwwwwwwwwwwu
|B |C|E|E|T|T|T|T|T|T|T|T|T|T|R |M |F | AC/ |
|l |O|M|M|R|R|R|R|R|R|R|R|R|R|F |C |U | DC
|i |N|R|R|X|X|X|X|X|X|X|X|X|X|T |A |T |
|n |N|P|P| | | | | | | | | | |L |/ |U | or |
|d | |M|M| |A|A|A|A|A|A|A| | | |M |R |
| | |/|/| |V|V|V|V|V|V|V| | | |C |E | DC |
| | |1|2|C|C|C|C|C|C|C|C|S|V| |B |/ | CONN |
| | | | |C|/|/|/|/|/|/|/|R|E| | |A | +
| | | | | |D|D|D|D|D|D|D| |R| | |L | blind|
| | | | | |V|V|V|V|V|V|V| | | | |M | plate|
| | | | | |C|C|C|C|C|C|C| | | | | |
|12|8|8|8|8|8|8|8|8|8|8|8|8|8|10|10|10| 22 | = 168 tvvvvvvvvvvvvvvvvvwu
mvj Filter, MCU & hybrid comb. COMBFILT 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 42 16 UNITS 16.1 GENERAL The units are designed to allow:
connection/disconnection with power on (not power local errors without disturbing other units via the supply, though) supply They are also designed to reset at low input voltage, so that erroneous behaviour, and possibly selfdestruction, does not occur. 16.2 REMUX The REMUX hosts three separate functions:
* PCM interface and supervision
* Rearrangement of DS0:s
* Clock stabilization and reference generation The REMUX terminates an incoming 1.5 (or 2 Mbit) PCM connection, changes the bitrate to 2 Mbit and provides two TLINK and four CLINK outputs for speech. Each carrying up to four DS0:s for speech. The TLINK:s are connected directly to the EMRPM:s in the same magazine via backplane connection. The CLINK:s are output on the front in four connectors. There is also a third TLINK output in the backplane to the "FUTURE" board slot, this is to prepare for a "HUB" functionality, or any other functions that require DS0:s from the incoming PCM. The mapping of DS0:s from the incoming PCM connection onto the CLINK:s and TLINK:s is totally flexible and controlled via the MSC. One of the incoming DS0:s can be defined as the control timeslot for the MB and is in that case always sent to the STRM board. Setting of this is possible only by local connection to the REMUX at site. The REMUX provides an outgoing 1.5 (or 2 Mbit) connection for cascading arrangements. In a cascading arrangement the PCM frame shall be configured to transmit unrearranged time slots through the REMUX, otherwisw the behaviour at start/restart, power loss etc will be poor. When the REMUX is reset or powered up, the entire PCM frame, except for the CTRL DS0, is transmitted through the REMUX (the REMUX is in state boot/init). 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 43 When the REMUX is powered down, the two PCMlinks are galvanically throughconnected via a relay. This can support future "passthrough" functionality, when the blocking functionality is improved (assuming common link format on both lines, of course) At the front there is an output/input for external air frame sync connection. The REMUX is controlled by the EMRPM over a TLINK. The REMUX has LED:s for:
Power Error
Status <>
Status <>
Green Red Yellow Yellow 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 44 Block diagram REMUX:
| relay
tn
PCM prim.|
E1/T1/DS1 |
PCM sec. |
E1/T1/DS1 |
lvk
| mwj
| lvk
| | mj
Line nj |
Listenernj lk Ext Air
Frame Sync|
| AFS
(Options) |
lk nu
nu CLOCK |
lu PLL:s |
lk
mwj
| A TLINK
tn
| D lvk
| R
| B TLINK
nwwuCSUtu tn
| I
| TIME
| Speech
| C CLINK
tu V
| E
| SWITCH |
tn nvwnuCSUtu
| D CLINK
tn
| E CLINK
mwj
tn
|Control
| F CLINK
tn
| G TLINK
tn
mj
mn u
| Ctrl
| DS0
| To
| STRM mnj lk
|PROCESSOR|
mwj REMUX setup
|TLINK from EMRPM The A,B and G TLINK:s are output via backplane. CLINKS CF are output at front for connection of further cabinets. REMUX performs automatic line code and frame format detection on primary PCM Line. Secondary one is configurable from MSC. CSU (Customer Service Unit) is an interface unit providing Loops Indications of line status Supervision data (in ESF frame format) 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 45 16.3 STRM The STRM is a standard STR board converted to building practice BYB 401 001. The STRM has connections for control timeslot and the EMRPbus. Back:
Front:
STRM EMRPB lk
Ctrl DS0 |
u t
From
| To further cabinets REMUX
| on the site
EMRPB u
To EMRPS:s|
in own
magazine |
mj The STRM has LED indicators for:
Power Status 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 46 16.4 EMRPM 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 47 The EMRPM is built upon an EMRPS base. The EMRPM and the EMRPS are totally compatible regarding application SW. The DEVSB interface is replaced by direct TTL drivers. There are 10 separate TLINK connections available on the EMRPM. The EMRPM hosts a simple multiplexor that combines control and speech DS0:s on the same TLINK. The EMRPM can also collect four internal alarms. The EMRPM also has two ports at front (one connector only) for terminal, BSTI and debugger. Front:
Block diagram:
Back:
10 DS0:s| Ctrl of
| TLINK lk
| speech
tn
| DS0:s 03
| Multiplexor
| valid
lk 1 tn
tu 2 tn
| D
3 tn mj
| R
| I 4 tn
| V 5 tn 6 tn
| E
| R 7 tn
| S 8 tn
9 tn lvk 10 tn
| TLINK:s mj tj
tn
| EMRPB lk
tn
| Port tn nu
tn
tu Port:s
tn mj
| Alarms mj lk
mj
| devices lk
|DIPswitch|
mwj CU The DS0:s are multiplexed and distributed due to a fixed pattern:
Speech:
TLINK #1 gets speech DS0 #0, TLINK #2 gets speech DS0 #1 etc. Control:
TLINK #1 to #6 are devices #05 in the EMRPM device map (TRX:s). TLINK #7 is device #17 in the EMRPM device map 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 48
(ALM). TLINK #8 is device #22 in the EMRPM device map
(Future device). TLINK #9 is device #16 in the EMRPM device map
(RFTL). TLINK #10 is device #21 in the EMRPM device map
(REMUX). For information about TLINK distribution in the magazine see section 7. For information about connection of internal alarms see section 10. 16.5 TRX The TRX is a multimode transceiver for transmission and reception of radio signals. The TRX can be used for the following channel functions:
Analog Control Channel Analog Voice Channel ACC AVC DCCH Digital Control Channel DTC Digital Traffic Channel Signal Strength Receiving SR VER Digital/Analog Verification DCCH and DTC can be present on the same carrier. TRX is capable of handling x DCCH and y DTC, x+y =3 1 DCCH and 5 DTC (expected performance with half rate)
(fullrate) The output power of one TRX is approximately 1.5W /
32 dBm. The dynamic range is 20dB, with resolution 0,2 dB. The TRX collects internal alarms from the two fans. For information about connection of internal alarms see section 11. 16.6 RFTL The Radio Frequency Test Loop is used in order to configure and supervise the microbase. The output power and RSSI measurement can be calibrated and the function of each TRX board can be fully tested remotely when not used for traffic. The RFTL also performs VSWR measurements to support the TX antenna supervision function. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 49 The RFTL requires a measuring coupler unit which is located to the COMBFILT unit. If double duplex is used, two measuring coupler units are used and hence the RFTL has inputs for two directional couplers. 16.7 MC The MC supports both A and B branches. The MC provides one signal for each branch to the backplane where power splitting is performed. The MC has outputs at front in order to serve up to two further microbase cabinets. In case of malfunction, an internal alarm is sent to the EMRPM:s via the backplane. 16.8 COMBFILT The COMBFILT unit exists in different versions depending on application:
A: No duplex B: Duplex on one Rx antenna C: Duplex on both Rx antennas, one cabinet The COMBFILTcan contain the following:
* Hybrid combiner
* Attenuator for Rx connection (located in the contact outside COMBFILT)
* Rx bandstopp filters
* Rx bandpass filters
* Measuring coupler unit(s) for RFTL
* Duplex filters The different COMBFILTversions are found in ref <5>.
(Customers can see the available versions in Ordering Information) 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 50 Block diagram, COMBFILT version B:
Rx B From TRX:s lk
| Band |
mj lk
| Band |
mj onu onu onu onu Hybrid combiner tk onu
onu
onu onu
Connect direct |..onj or via Cabinet |
combiner
|..onu Duplex lk
| lk
Antenna onu
| |MCUtu pass tu stop tk
From RFTL onu
| mj
To MC B onj
| lk
| mj
Forward |
Reflected |
mj lvk
onu
onu
| MCU |
From RFTL onu mwj Rx A/Tx Antenna lk
tk
mwj
lk
| Band |
mj
To MC A onu stop tj
onj To RFTL 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 51 16.9 CABCOMB The cabinet combiner CABCOMB is used if more than one cabinet shall belong to the same cell. Two different combiners are available depending on whether two or three cabinets shall be connected together. 16.10 POWER SPLITTER BACKPLANE The backplane contains power splitter for each branch. The MC only provides one signal per diversity branch and all splitting is performed in the backplane. All 10 TRX:s in the microbase cabinet receives the same signal at the same level. 16.11 AC/DC The AC/DC unit works on mains power supply and produces 24V for subunits. The AC/DC unit has one connector for fan unit. Fan internal alarm is transfered to the backplane. The AC/DC also has two switches at front to set the cabinet identity, 015 that denotes horisontal position and AF that denotes the vertical position. AC/DC has an internal alarm for malfunction that is sent to backplane. It also has an alarm for mains interrupt, which can origin either from the unit itself or from an external UPS equipment. 16.12 DCCONN The DCCONN unit is used when DC power supply is used. It needs 24V DC (see 12.1.1) as input and delivers 24V DC for subunits. The DCCONN unit has one output connector for the fan unit. The fan unit is supplied via a filter, which is located after the input fuse at the DCCONN. Fan alarm is transfered to the backplane via an EMC filter. The DCCONN also has two switches at front to set the cabinet identity, 015 that denotes horisontal position and AF that denotes the vertical position. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 52 The DCCONN has two internal power alarms. The alarms are activated when the DC power supply goes below certain values. Both the alarms can be enabled/disabled via switches. 16.13 FAN The FAN unit has two internal fans for redundancy, each having its own internal alarm in case of malfunction. 16.14 CONN The CONN board is used instead of a STRM board in all auxilary cabinets on a MB site. The CONN board connects two CLINK:s for speech, incoming/outgoing EMRPbus and incoming/outgoing air frame syncronization signal. The CLINK:s are converted to TLINK:s and output in backplane to TRX:s. The conversion for each CLINK has its separate power feed circuitry. The air frame syncronization signal is converted to TTL level and output via backplane. Also this conversion has its own power feed circuitry. Further the TTL output is disabled if a REMUX is present in the same cabinet. 16.15 BLIND FRONT PANEL The BLIND is used instead of a REMUX in auxilary cabinets not having a REMUX board. The BLIND ensures that EMC and cooling properties are kept unchanged. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 53 17 CONNECTION OF CABINETS 17.1 FORWARD RF (TRANSMIT PATH) Duplex filter in one branch:
lk TRX| H |
TRX| Y |
| B |
| R tk
| C |
TRX|
mj
o o o o
mj | | mj lk lk
| Cab | |
| comb | mwj
mwwwwj
o o o o o o o o
lk
| | Duplex tu MCU tk mj |
mnj
o oj oo
(= external cable) Main cabinet:
Aux 1:
Aux 2:
lk
TRX| H |
TRX| Y |
| B |
| R tooj |
| C |
TRX|
mj
lk
TRX| H |
TRX| Y |
| B |
| R tooj
| C |
TRX|
mj Two Duplex Filters The block diagram below shows how the TX branch is configured when there are two cabinets and two duplex filters in one cell. If there are three cabinets in the same cell, the "cabinet" combiners in the main cabinet have three inputs instead of two. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 54 AUXILIARY CAB.1
(884M)
.u
MAIN CABINET
(884M) lk mwj lk TRX8 u HC |
tk
TRX5 u mj
lk
TRX4 u HC |
tk |
TRX1 u
mj | |
mnj
| | lk lk lk
| mu HC |
lu HC |
. | TRX |
tu DUPLEX tu MCU tj tnu
. | 8 |
lvk |
mj
| TRX tj mj
| 5 tj
t PSPA
t PSPB
mj
| lk lk lk mu HC |
lu HC |
. | TRX |
. | 4 |
tnu DUPLEX tu MCU tj tu
lvk |
mj mj
| TRX tj
| 1 tj tk
tk |
mj
lk
| mu PSP |
t u mu PSP |
mj
lj
lk
| MCA |
.u A tu tj
t u
| MCB |
.u B tu tj
mj lk tk
mwwj |
lvvk |
| RFTL tj
tk mwwj |
lvvk | mnj
tj mj lk mwj
.u
10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 55 17.2 REVERSE RF (RECEIVE PATH) Abranch shown only, duplex branch:
Main cabinet:
Aux 1:
Aux 2:
lk lk
|DuplextuMCU|
mwj
mwj
mnj 0dB |
ooj 2/1dB *
+4.5/5.2dB +16dB lk lk
| M |
TRXu
| C took TRXu P |
| A |
| S |
| P tu / |
| B |
| M took |
| C |
| B took | |
TRXu mj mj+1/0dB | | |
| | moo
| mk
mk |
lk lk
| M |0dB
TRXu
| C tooouAttenuatortooj |
TRXu P |
| S |
| A |
| P tu / |
| B |
| M |
| C |
TRXu
| B |
mj mj
lk lk
| M |
TRXu
| C tooouAttenuatortooj TRXu P |
| S |
| A |
| P tu / |
| B |
| M |
| C |
TRXu
| B |
mj mj lk mj lk mj oo
(= external cable)
* with/without band reject filters Note that the level figures are approximate. Look in ref. 5 to find the valid ones. The Auxiliary cabinets do not have any filters. In order to get the same signal levels as in the main cabinet
(and in RBS882m), attenuators have been inserted. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 56 17.3 SPEECH AND CONTROL Main cabinet:
Aux 1:
Aux 2:
PCM in u lk lk
| S |
| R |
| T |
loou E |
| R took
| loou M |
| M |
| U |
loou X |
|E
| loou
|M
mj
|R
mj
|P
|B
lk
| C tooj
| moou O |
| N |
moou N |
took
|E
mj
|M
|R
|P
lk
|B
| | CLINK:s for speech
| C tooj
| moou O |
| N |
moou N |
EMRPB
too...
mj oo
(= external cable) To possible further cabinets on MB site 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 57 17.4 AIR FRAME SYNCRONIZATION Main cabinet:
Aux 1:
Aux 2:
Main Cabinet 2:
External reference
(Option) oou oo
(= external cable) lk
| R |
| E |
| M |
| U |
loou X |
mj lk
| C |
moou O |
| N |
loou N |
mj
lk
| C |
moou O |
| N |
loou N |
mj
lk moou
| C |
| O |
| N |
| N |
mj lk
| R |
| E |
| M |
| U |
loou X |
mj
The figure shows the connection of the air frame syncronization signal on one MB site where more than one input PCM line is used (that is, more than one REMUX is used.). 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 58 18 CONNECTION OF CABINETS 882M/DM884M 18.1 CONTROL PATH Control is carried via the EMRP bus (EMRPB). EMRPBconnection is available on both STRP and STRM fronts, so that one EMRPB can be connected to another cabinet. When connecting from 884M to 882M/DM, the EMRPB cable goes to the EMRP/EMRPAT/EMRPMD front connectors. When connecting from 882M/DM to 884M, the cable is connected to the CONN board, which feeds it to the backplane distribution in the same cabinet, and further cabinets connect to the throughconnect connector on CONN. Note that there can only be one EMRPB to EMRPM. APZ currently requires that both STC/STRpairs in an EMG are of the same type (see ref 11). It is therefore currently not possible to connect the current STRP in the same EMG as the STRM. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 59 Main cabinet:
884M Aux 1
(if it exists) Aux 2:
(if it exists) RBS882M/DM Auxiliary Cabinet u out |
lu
mu T | . lk PCM in lk
| S |
| R |
| T |
loou E |
| R took
| loou M |
| M |
| U |
|E
| | loou X |
|M
| | | loou
mj
|R
mj
|P
lk
|B
| C tooj
| | | moou O |
| N |
| | moou N |
tookE
mj
|M
|R
lk
|P
| | CLINK:s for speech
|B
| C tooj
| moou O |
| N |
moou N |
tookE
mj
|M
................ |R
. |P
. lk lk ..... |B
too.. |
| E |
| M |
| D | . S . |
| R |
| I |... T ......
| / | . R . possible | P |
| M | . P . 2nd
| I | . toou
. EMRPB
| N | .
| I | . mj to further EMRPs
. mwj .....
m/ to MTM/DMTMs N wires carrying speech oo
(= external cable) 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 60 18.2 RF PATHS It is possible to locate up to three micro base stations in the same cell. This document describes how the antenna near parts are configured when several base stations have a common antenna system. The RBS884M is only planned for connection to an RBS882M/DM without MCPA, although this configuration is, in principle, possible. It is not verified and no cables, application rules etcetera are documented. The RBS884M is assumed to be connected to the antennas directly, so that the RFTLsupported functions work as planned, i.e. with reference to the feeder connection. RBS882M is described in ref. 10. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 61 18.2.1 One duplex filter 18.2.1.1 TX branch Below there is a block diagram showing how the TX branch is configured when there are three cabinets in one cell. If there are two cabinets in the same cell, the second combiner in the main cabinet has two inputs instead of three. oo
(= intercabinet cable) AUXILIARY CAB.2
(884M or 882M) AUXILIARY CAB.1
(884M or 882M) MAIN CABINET
(884M) lk TRX1 u HC |20dBm
TRX8 u
TRX8 u took
mj
lk
TRX1 u HC |20dBm |
took |
mj
| moou HC | 15dBm moou
|ook
tu
| 20dBm mj o o lk mj lk lk lu HC |
. | TRX |
| .u
. | 8 |
lvk |
| TRX tj
| 1 tj tk
tk |
mj
o
lk lk o
| MCA |
| mu PSP |
tooj tu
t u t u 0dB
| MCB |
mu PSP |
too tu
o mj mj o
.u
.u
mnj
lk
| DUPLEX tu MCU tj mj
lk
tk mwwj |
lvvk |
| RFTL tj tk
mj |
lk | mnj
tj mj lk
| RXBP tu MCU tj mj The TX levels are nominal power levels per carrier. Level values are provided for information, they are not formal specifications. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 62 If one cell consists of RBS 882M cabinets only, one of them is the main cabinet. The cabinets are connected in the same way as shown in the figure above. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 63 18.2.1.2 RX Branch Below there is a block diagram showing how the RXA branch is configured when there are three cabinets in one cell. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 64 Levels rel. to input:+4.5/5.2dB
+16dB 2dB 0dB
.u
lk lk lu HC |
. | TRX |
tk
. | 8 |
lvk |
| TRX tj
mj
| 1 tj
tk
tk |
mj
lk
lk
| mu PSP |
| MCA |
tu tj
t u
t u mu PSP |
| MCB |
tu tk
mj
mj
.u
.u
mnj lvk
| DUPLEX tu MCU tj mwj lk
tk mwwj |
lvvk |
| RFTL tj
tk mj |
lvk lk | mnj
| RXBP tu MCU tj mj |
tj
. mj
. 1dB
. lk
. TRX1 u PSP | lk lk TRX2 u A | | MCA | | BAND | lk tu REJECT tu DUPLEX too
| | FILTER | mj tu
| mwwj mj
TRX10 u mj
+1dB (882M/DM)
TRX10 u
| |0dB
| |ook mook |
lk
TRX1 u PSP |
lk0dB
TRX2 u A |
| MCA |
toou FIXED ATTEN tj |
tu
mj mj
lk TRX1 u PSP |
lk0dB TRX2 u A |
| MCA |
toou FIXED ATTEN tj tu
mj mj lk mj lk mj
TRX10 u MAIN CABINET
(884M) AUXILIARY CAB.1
(884M or 882M) AUXILIARY CAB.2
(884M or 882M) The RBS 882M cabinets contain eight transceivers and accordingly the power splitter has eight outputs. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 65 In the auxiliary cabinets the receive filter part of the duplex filter and the band reject filter are replaced by a fixed attenuator (cable). In the RXB branch there is a receive filter (RXBP) instead of the duplex filter. Otherwise there are the same blocks as in the RXA branch. 18.2.1.3 MCPA The figure below shows how to connect an MCPA. In the figure the main cabinet is RBS 884M. If the main cabinet is RBS 882M, the MCPA would be connected in the same way. Note that the Duplexfilter etc for RBS884M is not designed for higher power than from the hybrid combiner, so this only shows a principle. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 66 AUXILIARY CAB.2
(884M or 882M) AUXILIARY CAB.1
(884M or 882M) MAIN CABINET
(884M)
TRX8 u lk TRX1 u HC |
tk
mj
lk
TRX1 u HC |
tk |
mj | |
TRX8 u lk lk | mu MCPA |
mwj
mnj lvk
| DUPLEX tu MCU tj mwj
lk lu HC | mu
. | TRX |
tu
| .u
. | 8 |
lvk |
| TRX tj mj
| 1 tj
tk
tk |
mj
lk
lk
| mu PSP |
| MCA |
tu tj
t u
t u mu PSP |
| MCB |
tu tk
mj
mj
.u
.u
lk
tk mwwj |
lvvk |
| RFTL tj
tk mj |
lk | mnj
tj mj lvk
| RXBP tu MCU tj mj 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 67 18.2.2 TX and RX Filters Below there is a block diagram showing how the TX branch is configured when there are three cabinets in one cell and separate TX and RX filters. AUXILIARY CAB.2
(884M or 882M) AUXILIARY CAB.1
(884M or 882M) MAIN CABINET
(884M)
TRX8 u lk TRX1 u HC |
tk
mj
lk
TRX1 u HC |
tk |
mj | |
| | lk
TRX8 u
mnj lk | mu HC | lk lk
tu TXBP tu MCU tj
| mj mwwj mj lk lu HC | mu
. | TRX |
| .u tu
. | 8 |
lvk |
mj
| TRX tj
| 1 tj
tk tk |
mj | |
lk lk
| MCA |
| mu PSP |
tj tu
t u t u
| MCB |
mu PSP |
tk tu
mj
mj
.u
.u
lj |
| lj
mnj lk lk | |
| RXBP tnnu MCU tj
mwj | |
tk mj |
lvvk
| RFTL tj
mj tk
lk | mnj
tj mj lvk
| RXBP tu MCU tj mj The RXA and RXB branches are configured in the same way as the RXB branch in section "One duplex filter". 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 68 18.2.3 Two Duplex Filters The block diagram below shows how the TX branch is configured when there are two cabinets and two duplex filters in one cell. If there are three cabinets in the same cell, the "cabinet" combiners in the main cabinet have three inputs instead of two. AUXILIARY CAB.1
(884M)
.u
MAIN CABINET
(884M) lk mwj lk TRX8 u HC |
tk
TRX5 u
mj lk
TRX4 u HC |
tk |
TRX1 u mj | |
mnj
| | lk lk lk
| mu HC |
lu HC |
. | TRX |
. | 8 |
tu DUPLEX tu MCU tj tnu
lvk |
mj
| TRX tj mj
| 5 tj
t PSPA
t PSPB
mj
| lk lk lk mu HC |
lu HC |
. | TRX |
tnu DUPLEX tu MCU tj
tu
. | 4 |
lvk |
mj mj
| TRX tj
| 1 tj
tk tk |
mj lk
| mu PSP |
t u
mu PSP |
mj
lj
lk
| MCA |
.u A tu tj
t u
| MCB |
.u B tu tj
mj lk
tk mwwj |
lvvk |
| RFTL tj
tk mwwj |
lvvk | mnj
tj mj lk mwj
.u
10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 69 The RXA branch as well as the RXB branch are configured in the same way as the RXA branch in section "One duplex filter". 18.3 SPEECH PATH AND CLOCK INFORMATION Speech and clock reference is carried on the E1/T1 PCMlink between the RBS882M/DM and RBS884M. This is connected on the fronts between REMUX and TDI or MINI. It is recommended to put TDIs "last in the chain", because clock failures in TDI might not create any system alarms or actions, and base stations depending on that clock may thus provide poor service and operate outside TIA specifications. RBS884M and 882DM provide alarms. RBS884M can keep the stability for several days. The 882DM and 884M can be connected in any order. However, present SW does not provide full performance regarding restart behaviour and link supervision, so the RBS884M is still recommended to be put first in the chain. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 70 Main cabinet:
884M Aux 1
(if it exists) Aux 2:
(if it exists) RBS882M/DM Auxiliary Cabinet PCM in lk
| R |
| E |
| M |
| U |
| X |
mj u out |
lu
lk
mu T |
| D |
| I |
| M |
lu I |
| N |
| I |
mj to further base stations 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 71 19 HW SUPPORT FOR TRAFFIC FUNCTIONS The HW is designed to allow any channel EMRPM or TRX, i.e. free allocation, except for the two positions without connection to the TX antenna. Possibilities to assign backup units is thus maximized. Different CFUs cause different EMRPM load, so it is recommended to use the recommended assignment, if future upgrades increase the load. function in any The HW is not prepared for nonIS54 characteristics like dynamic (timeslot) BS power regulation or CDMA. Some HW must be replaced to allow this. The HW is prepared for Air Frame Sync, i.e. all TRXes operate at the frame timing (in digital mode). This timing can also be derived from an external source, e.g. a GPS receiver. RBS884M is designed to support CDPD modulation (with SW reload) The following functions and features are prepared in hardware, but will not have system support softwarewise:
Analog verification (= AVC) in dualmode verification The product is not prepared for:
ADPCM/PCM transcoding in analog mode BS power regulation dynamically (e.g. per time slot) There are no specific traffic functions related to the RBS 884M. Functions supported is equivalent to RBS 882 and RBS 882D. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 72 20 HW SUPPORT FOR STANDARD O&M FUNCTIONS All functional descriptions in this document are limited to the HW support, primarily for functions without system support, i.e. where there is no other function documentation. 20.1 EVENT LOG Each device has an internal event log that stores the 10 latest serious faults or major failures. It also stores the 10 latest minor faults since the last serious fault or major failure. The Event log can be read over the TLINK/CLINK interface only, normally in the repair shop. No system support via CP. 20.2 DEVICE RECOVERY The recovery intends to filter out occasional, temporary, errors ("false alarm"). If a device reports a serious fault the system will respond with a blocking order. After five minutes the system will try to reset and start the device again. If a new serious fault is received within three minutes, the device will be blocked again and no further attempts to recover will be performed. 20.3 BACKUP OF CC/DCCH/SR/VER If there is a malfunction in the equipmentment providing the CC function, the system (meaning MTS) is automatically moving the CC function to a predefined
"CEQ". The same support is available for SR (as in earlier packages), but in this package with additions for VER and DCCH backup. All backup functions are "owned" by MTS, MBS only supports these functions. The MTS function only allows reconfiguration from the "essential" channel functions to VC/DTC. The MBS architecture, and RBS884 HW, supports flexible allocation of backup channel to any device. This enables flexible HW upgrading, where different units may be merged, as the HW is rationalized. The backup "CEQ"
should be chosen so that original and backup units share as little HW as possible, maximizing the system availability. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 73 20.4 TEST AND MONITORING OUTLETS There are only two kinds of monitoring outlets:
one per PCMline, connected on REMUX a measurement coupler per antenna connection. This is the MCU used by RFTL, if the RFTL is installed. The RFTL shall be blocked first, because the cable MCURFTL must be removed 20.5 BASE STATION TEST INTERFACE (BSTI) The possibility to connect a PC to the EMRPM in order to log and insert signals for test purposes. Not to be used by customers. 20.6 CSU FUNCTIONS The REMUX can support the functions normally supported by a Customer Service Unit applied on the PCM line connection. This includes test loops. 20.7 ALARM ON POWER FAILURE The base station will, via EMRPM, send an alarm to the MSC. The operator can thus decide on the correct action without going to the site. This function can be disabled manually by strapping the AC/DC for extended holdup of TRXes, too, not only CRIparts. If DC power supply is used, there are two switches on the DCCONN that can disable the alarm functions on power failure. If the alarm functions are enabled and an alarm is activated, an alarm is sent to the MSC via the EMRPM. 20.8 VOICE LINE CHARACTERISTICS Both analog and digital voice channels have selection of A or ulaw PCM coding, voice level adjustment (up and downlink separately). It is implemented in TRAB for digital mode and in TRX for analog mode. 20.9 HOT REPAIR All units, except the AC/DC or the DCCONN, can be extracted/inserted in powered magazines, without being damaged or other units being disturbed electrically. Normal blocking/deblocking procedures should be used to avoid traffic disturbancies. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 74 20.10 BYPASS AT POWER FAILURE The REMUX automatically connects the two PCMlinks at power failure (in +24V, i.e it connects after >700ms, if the "alarm enabled" mode is selected). There are limitations imposed by synchronisation behaviour, PCM link formats etc, so this is a basic HW preparation for future. more complete, functional support. This feature reduces the need for battery backup in small base stations 20.11 BASIC FAULT HANDLING AND INDICATIONS 20/10567/FCP 103 211 shows:
Indicators Marking Cabinet Identity Switch CLINK placement Numbering of racks and subunits 7/1551ANT24401 shows how to mark RBS884 units 10/10567/FCP103211 shows Redundant power feed Exchangability with power on Fault detection False alarms Reset response Selftest of devices Selftest of support processors Selftest at power up
(lack of) need of tools All devices have an algorithm to prevent "hanging devices" by resetting the whole application in case of loss of control communication (exceptions are now REMUX and ECU) 20.12 LIMITATIONS The following functions and features are prepared in hardware, but will not have system support softwarewise in the current release:
Control outputs SW and HW information Fault signal filtering Pin pointing of faulty unit / Error log RSSI calibration RF testloop Statistical supervision of DTC 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 75 APTalarm for faulty RFTL APTalarm for faulty ALM (nonexistant in this package) 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 76 21 HW SUPPORT FOR OPTIONAL O&M FUNCTIONS 21.1 RF TESTLOOP WITH RFTL The HW supports the following function, but there is no system support yet. The RFTL can be used to test the Tx and Rx RFpaths. A TRX is ordered to transmit a predefined modulated carrier. RFTL picks up the signal via the measuring coupler unit. The signal is mixed and transferred to the MS transmitting band and fed out on the Rx branches via the MCU. Any TRX can then be ordered to measure the signal in order to check TRX and RFpath functions. 21.2 EXTERNAL ALARMS The microbase cabinet is prepared for installing one ALM unit and thus providing the following, future, functionality. If an ALM board is used, up to 32 external alarms can be connected. The function can be defined as open or closed for alarm, for each input. Each input is of currentloop type, sourced by ALM. The external alarm switch is assumed to be galvanically floating. See ref. 9!
An activated input can produce an alarm along with an alarm printout. Alarm class and slogan is set manually by command. 21.3 CONTROL OUTPUTS The microbase cabinet is prepared for installing one ALM unit and thus providing the following, future, functionality. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 77 If an ALM board is used, up to 8 output control ports are available. Each output provides a closed connection when activated. The ports are controlled by manual command. Function:
lk
| o o
| Activation o o
mj See ref.9!
Output 21.4 SW AND HW INFORMATION The HW supports the following function, but there is no system support yet. The function provides a printout of base station equipment. Lists can potentially be produced on MSC, site or device level. The printout contain information about:
SITE CABINET_NUMBER POSITION_NUMBER HW_PRODUCT_NUMBER HW_REVISION HW_SERIAL_NUMBER PRODUCT_FUNCTION_CODE REVISION_FUNCTION_CODE SYSTEM_FUNCTION_CODE SW_PRODUCT_NUMBER SW_REVISION 21.5 POWER BACKUP If this is needed, it must be provided by an external UPS. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 78 22 PERFORMANCE For general radio performance se ref <2>. 22.1 CAPACITY Capacity refers to both processing capacity and memory capacity. The figures given are targets. The intention is that EMRPM shall be capable of handling CC + 2 DCCH + 7 DTC (full rate) plus various low load devices like REMUX, ALM, RFTL and FUTURE, or 2 DCCH + 22 DTC (half rate). TRX shall be capable of carrying 3 DCCH or 6 DTC (half rate). 22.2 APZ LIMITATIONS No of EMGs < 256 (depending on APZ version). Will be extended, but not as part of NOVA2project No of TWs < 2048 (?) . This is an extension to allow two TWs per base station for redundancy reasons 22.3 CHANNEL SEPARATION 120 kHz 22.4 RESTART AFTER POWER DOWN The MB starts up automatically after a power down/up. The EMRPMs will reload. The present APZ functions will provide parallell SW loading of the EMRPMs. The devices are normally loaded after powerup, due to the nonvolatile memory. This is normally without problem. The exception may be if the BS is powered down during a function change. 22.5 RESTART AFTER LINK FAILURE The MB starts up automatically after a link failure. 22.6 SMALL SYSTEM RESTART Generally no calls are dropped during a small system restart, that is classified as a "minimal restart". However, control signalling is interrupted for a while, which could result in dropping calls that 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 79 are in critical states like handoff. Another exception is the calls handled by the EMRPS/M causing the restart (if it was caused by an EMRP fault). This EMRPS/M will be subject to a "complete" small restart, which will drop all calls in this EMRPS/M and in the other EMRPS/Ms in the same EMG (The small restart is classified as complete or minimal per EMG) 22.7 LARGE SYSTEM RESTART All calls are dropped during a large system restart. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 80 23 REDUNDANCY STRUCTURE There is no redundancy in the RBS884M. AC/DC or DC is supplied for each cabinet. The EMRPMs control specific devices and are thus not capable of sharing the load. There is only one PCM link to MSC. TRXs are inherently redundant via "Backup" or manual reconfiguration, but capacity is reduced at failures. The singular units are controlled via one EMRP, to reduce the risk of total failures. 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 81 24 CERTIFICATION The environmental specs state the performance. In addition formal certifications are achieved for:
FCC Part 22 + corresponding DOC (Canada) FCC Part 15 + corresponding DOC FCC Part 68 for leased lines 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 82 25 ACRONYMS AND ABBREVIATIONS ACC ADC ADPCM AFS ANP_ATT AVC Analog Control Channel American Digital Cellular Adaptive Differential Pulse Code Modulation, a method of digital voice coding Air Frame Syncronisation signal into TRX The estimated ANP attenuation for a RCG Analog Voice Channel BSTI CDPD CFU DEVCB DCCH DCCONN DS0 DTC E1 EMC EMG EMRP EMRPM EMRPS ESD ETB EXT_AFS MB MBS MBC MC MCU MSC OCXO PSPB RCG REMUX RF RFTL SR SRR STRM T1 TSW TRX Base Station Test Interface Cellular Digital Packet Data Channel FUnction, AVC/DTC/LOC/ACC/DCCH/VER Device Control Bus Digital Control Channel DC connection board One 64 kbit channel (timeslot on a PCM connection) Digital Traffic Channel CCITT standard 2048kb/s PCM line Electromagnetic Compatibility Extension Module Group Extension Module Regional Processor EMRPMicrobase specific EMRP Speech bus interface Electrostatic Discharge Exchange Terminal Board External Air Frame Syncronization signal Micro Base Mobile Base station Subsystem Micro Base Cabinet Multicoupler Measuring Coupler Unit Mobile services Switching Centre Oven controlled crystal oscillator; highly stable osc. Power Splitter Backplane Radio Cabinet Group MB interfacing board Radio Frequency Radio Frequency Test Loop Signal strength receiver function Redundant SR STR in BYB401001 building practice American standard for 1.5 Mbit PCM lines Time SWitch; a time slot selector Multi mode transceiver device 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 83 UPS VER VERR Uninterruptable Power Supply VERification device for DTC Redundant VER 10_1551ANT24401.WTEK Uppgjord - Prepared ERA/AR/S/TH,AR/SK/AFOL Dokansv/Godk - Doc respons/Approved ERA/AR/SK
(S Hellmark) Faktaansvarig - Subject responsible Kontr - Checked Description Nr - No 10/1551ANT244 01 Uen File Datum - Date RULIB 19970515 Rev C 84 26 REFERENCES 1. TLINK layer 1 56/155 19ANT244 01 2. RBS884M microcell base station RF air interface requirements. 5/10567/FCP103307 3. Site grounding principles, 1/1531ANT 244 02 Uen 4. EMC guidelines on cabinet level, 5/1056ANT 244 02 Uen 5. Requirements on functions and performance in ANP for RBS884M, 7/10567/FCP103307 (Ericsson internal document, used during development phase)) 6. Environment spec 3/1025ANT24401
(This is the Ericsson internal requirement. Guaranteed performance is stated in 15502HRBxxx for the relevant product family) 7. Environment spec 4/1025ANT24401
(This is the Ericsson internal requirement. Guaranteed performance is stated in 15502HRBxxx for the relevant product family) 8. TLINK layer 1 56/15519ANT24401 9. External alarm and control interfaces 47/15519ANT24401 10.RBS 882M Micro Base Station Unit Description, 1551HRB 101 16. 11.APZ1993, RPS hardware and regional software TX/R93:079 Uen, rev. B 12.Product Specification 15502HRB10413 Uen, rev. B 10_1551ANT24401.WTEK APPLICANT:
Ericsson Radio System AB EXHIBIT 8 FCC ID NO. B5KKRC12110-11 EPLANATION 2W TRX IN RBS884 BASE STATION Explanation The 2 watt TRX KRC 121 10/1 is not mentioned in the description for the RBS884 Base Station. The unit is identical to the 11 watt TRX KRC 121 10/2 except for the last transistor in the power amplifier. So the description is appropriate for KRC 121 10/1 also, with this in mind. E Uppgjord Prepared ERA/AR/SL GFO Godknd Approved ERA/AR/SL (S Hellmark) Description Datum Date 1996-08-02 Rev C Kontr Checked 1 (36) Dokumentnr Documentno 8/1551-ANT 244 01 Uen Tillhr/referens File/reference CMS88 DQI status: EXITED - Estimated remaining major error/page: 6.5 RBS884 Base Station Hardware Technical Description Abstract This document describes the macro base station for the 800 MHz band pro-
vided by the RBS884 platform. It describes the hardware structure with focus on system level to give an overview of the fundamental parts and structures. More details can be found in supplementary documents. The document shall be used as a supplement to the description of the MBS subsystem for under-
standing of the RBS884 base station concept. The acronym RBS884 alone is the generic name of the macro base station for 800 MHz. Application Introduction of customers and Ericsson personnel to RBS884 HW. Supplementary documents
[1] Description of MBS, 1551-ANT 244 01
[2] 1551-COA 109 294, Control Part
[3] 1551-COA 109 295, Modem Par
[4] 1551-COA 109 296, Antenna Near Part
[5] 1551-COA 109 298, Support Part
[6] LZB 119 722, Equipment Practice Contents 1 2 3 4 5 6 7 8 9 Revision Information Introduction Features Limitations Base station structure Functional submodules and units EMC and grounding principles Environmental and safety Basic fault handling and indications Page 3 4 5 5 6 7 8 10 10 E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 2 (36) 10 11 12 13 14 15 16 17 18 19 20 21 22 Base station interfaces The control structure The RF structure Synchronization Power supply and power distribution Redundancy structure CO-siting Capacity HW support for Trafc functions HW support for Standard O&M functions HW support for Optional O&M functions References Vocabulary 13 16 17 18 20 21 25 26 30 31 32 33 34 E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 3 (36) 1 Revision Information PB2-3 Second non-reviewed version based on Rev A and following the guidelines outlined in AR/BU-94137 rev A. PB3->B Updated in accordance with 63/1776-5/FCP&rbl103&rbl553 B->PC1 50W added PCx->C Updated and approved in accordance with AR/S-96:061 E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 4 (36) 2 Introduction The RBS884 base station is divided into well dened functional parts named COP, MOP, ANP and SUP. The intention is to make it possible to reuse parts of the system for developments concerning other systems and to perform independent improvements of the dened areas. rbs884macro MSC NI Transmission Network T1 or E1 connection NI COP MOP ANP Rx Rx Tx SUP BS TRA ETC NI GS
#9/16 RP RP RP STC CP Figure 1 RBS884 HW block diagram The RBS884 supports transcoder location in MSC only, which improves the transmission capacity by a factor three. The RBS884 is a fully multimode i.e. has all channel functions:
- Digital Traffic Channel, DTC
- Digital VERification, DVER
- Control Channel, CC
- Analog Voice Channel, AVC
- Signal strength Receiver, SR
- Digital Control CHannel, DCCH All carriers on a site are prepared to be TDMA frame and slot synchronized. The RBS884 platform utilizes equipment practice BYB 401 001. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 5 (36) 3 Features The RBS884 is designed for medium to high output power per carrier. 10 W transceivers or 30 W transceivers or 50 W transceivers can be selected. The RBS884 can be congured as an omni site, a two sector site or a three sector site. The RBS884 supports various cell patterns 7/21 and 4/12. The RBS884 highly scalable and its physical size depends on the maximum output power per carrier, the numbers of sectors and the number of carriers per sector. As an option the RBS884 can be equipped with a Tower Mounted Amplier to balance the uplink RF-path and the downlink RF-path to increase coverage. 4 Limitations The following functions and features are prepared in hardware, but will not have system support software-wise:
- Analog verification (= AVC) in dual-mode verification
- Control outputs
- SW and HW information
- Fault signal filtering
- Pin pointing of faulty unit / Error log
- RSSI calibration
- RF test loop
- Statistical supervision of DTC
- APT-alarm for faulty RFTL
- APT-alarm for faulty ALM (non-existant in this package)
- Setting of MCU attenuation value per RCG (not needed on CMS88-markets) The RBS884 is not prepared for:
- ADPCM/PCM transcoding in analog mode
- BS power regulation dynamically (e.g. per time slot) The RBS884 also have the following limitations:
- Cannot be used as a HUB to connect subordinated BSs to the MSC
- Cannot be cascaded
- Has no integrated power rectifiers
- Has no unit generating the Air Frame Sync (AFS) E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 6 (36) 5 Base station structure The base station consists of the following major functional parts:
rbs884macro1 COP MOP ANP MSC ETB
#9/16 STR EMRP T S W SUP TRX PS MC COMB Rx Rx Tx DC distribution AC/DC BAT AC Mains Voice & Data paths Control paths Radio Frequency paths Figure 2 The RBS884 structure COP-Controlpart Handles the communication with MSC and hosts the hardware for radio trafc control, statistics and control of MOP and ANP The COP is the SW-loadable part of the base station. For more information refer to Supplementary Documents [2]. MOP-Modempart Serves as the converter from speech and digital information into radio waves and vice versa. Hosts channel codec function and performs measurements on radio transmission quality. MOP consists of non-loadable HW. However, the TRX program memory can be changed from MSC by command, for correction purpose. The transcoder, TRA, is logically part of the modem part but it is physically located in the MSC. For more information refer to Supplementary Documents [3]. ANP-Antennanearpart Hosts the equipment associated with forward and reverse RF, such as com-
biners, multicouplers and power splitter. Also provides equipment for looping of radio signals, output power measurement, reected power measurement, RSSI calibration, external alarm collection and control of external equipment. ANP consists of non-loadable HW. However, the program memory of RFTL, E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 7 (36) ALM and CTC can be changed from MSC by command, for correction purpose. For more information refer to Supplementary Documents [4]. SUP-Supportpart Provides DC power distribution to the base station hardware. Consists of DC distribution rails, connectors, circuit breakers and fuses. For more information refer to Supplementary Documents [5]. EquipmentPractice All BS equipment is assembled in cabinets of uniform design and size, Width 600 mm, height 400 mm and depth 400 mm. The cabinets provides the me-
chanical structure and air forced cooling for the BS. The cooling capacity can be adapted to the needs for the equipment type housed in one specic cabinet. For more information refer to Supplementary Documents [6]. 6 Functional submodules and units The functional parts, COP, MOP, ANP and SUP, are built up by functional submodules, hosted in cabinets of equal size. Each functional submodule then contains a number of different boards or units. The functional parts, COP, MOP, ANP and SUP are built up by the functional submodules:
Controlpart:
* CRI Modempart:
* TCB Antennanearpart:
* ATCC
* ANPC Supportpart:
* POWD A RBS884 BS consists of at least one functional submodule from each func-
tional part. By appropriate number of submodules the total capacity of each functional part can be adapted to the needs of a specic BS. The gure 3 and the gure 4 gives some examples E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 8 (36) TRX 10 W. 3 * 24 CARRIERS. SECTORSITE CRI POWD POWD ANPC ANPC TCB TCB TCB ATCC ATCC TCB TCB ATCC ATCC CRI TCB ATCC ATCC CELL #1 CELL #2 CELL #3 conf TRX 10 W. 24 CARRIERS. OMNISITE POWD CRI ANPC ATCC ATCC TCB TCB TRX 30 W. 3 * 24 CARRIERS. SECTORSITE POWD POWD CRI CRI ANPC ANPC TCB TCB TCB TCB ATCC ATCC TCB CELL #1 TCB TCB ATCC ATCC TCB CELL #2 TCB TCB ATCC ATCC TCB CELL #3 Figure 3 The RBS884 congurations, example 10 W and 30 W conf800wac TRX 50W. 3*32 CARRIERS. SECTORSITE POWDa TCB n CRI c POWDb TCB r POWDc ANPC1 CRI a TCB o ANPC2 TCB p CRI 2 TCB g TCB h ATCC3a ATCC3b TCB d TCB e TCB q TCB a TCB b ATCC3c TCB k TCB f TCB c Figure 4 The RBS884 congurations, example 50 W 7 7.1 EMC and grounding principles EMC zones To describe the EMC concept a division into different zones is useful, reference [1]. Each zone has it own EMC characterization, as follow:
Zone 0 is the surrounding of the base station. Zone 1: Transients from zone 0 are attenuated. Suitable to contain electronic devices with low radiation and low susceptibility. The ground characteristics of zone 1 is that it is equipotential, which means that every part of the ground in zone 1 has the same potential to earth (zone E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 9 (36) 0) in every moment. This is the base for protection against external transients and ESD. The ground structure shall be made to encircle the base station. This creates a "wire shield", which is useful for protection against the elds connected to transients and conducted lightning, see ref [2]. All cables shall enter the Zone 1 via one and oly one intake point. Zone 2: Shielded from zone 1, and cables are ltered when passing the shield. The interior of zone 2 is equipotential and the shield is a part of the ground structure. The shield must be bonded to the ground structure in zone 1. Zone 2 is intended to contain unshielded electronic digital devices. These has medium emission and medium susceptibility. Zone 3: Shielded from zone 1 and 2, and cables are ltered when passing the shield. Zone 3 is intended to contain radio equipment. Zone 3 contains circuits with high emission levels or high susceptibility, which means radio units. 7.2 Grounding principles 7.2.1 External connections and shields. All cable shields must be terminated at the intake point. All external leads must have transient protection devices mounted close to the intake point (The Centre lead of the antenna cables are excluded). If the transient protection devices require connection to ground this shall be done at the intake point. 7.2.2 Cabinet interconnection. All parts within the cabinet shall be grounded together. This shall preferably be done with metallic contact of the structures (called direct bond). If this is not possible, a short braided strap may be used. (Indirect bond). 7.2.3 Submodule. Inside the submodule multipoint ground is used, and the ground planes of the boards are usually connected to both front and backplane. This is permitted but not required. The board magazine is designed according to BYB 401 001 and is covered by a shield. This shield is a part of the ground structure of the board magazine. The shield is grounded to the cabinet. 7.2.4 Fan unit. The fan unit is grounded to the cabinet. This is required because of the RF-lters in the unit, and to reduce possible emission from the unit. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 10 (36) 8 9 Environmental and safety The RBS884 is designed to withstand transport, storage and normal operation over a wide area of temperature, humidity, air pressure etc, see ref [3]. Also specied are ranges for safe operation and non destructive operation. The RBS884 is designed to full safety requirements dened by ref [4]. Basic fault handling and indications The RBS884 supervision and fault handling is supported by hardware by a number of basic functions described below. 9.1 Cabinet numbering and board positions Each cabinet in a site conguration has a unique number, the CID code. The number is set by a switch in each cabinet and is read by all units in the cabinet. Within each cabinet each board has unique board position code from left to right. Each unit in the cabinet reads the board/unit position within the cabinet. All units/boards having onboard processor unit are capable of reading the above explained information. Detailed information in this subject is found in ref [5] and [6]. 9.2 Device product info and event log Each HW unit has the following product related information stored in HW and impossible to change during operation. The information is accessible remotely if the unit is equipped with a processor:
* Product number
* Revision state
* Product Serial number Each HW unit has the following function related information stored in HW and impossible to change during operation. The information is accessible remotely if the unit is equipped with a processor:
* HW generation
* Product function code
* Revision function code
* System function code Each SW unit has the following product related information stored as part of the SW unit. The information is accessible remotely:
E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 11 (36)
* Product number
* Revision state Each SW unit has the following function related information stored as part of the SW unit. The information is accessible remotely:
* Program version
* Program revision
* Program function code Further each exchangeable unit keeps an event log for two event categories, Alarm and Fault. The event log shall contain the following:
* One alarm log storing the 10 latest events resulting in alarm, major failures and serious faults, sent to the MSC.
* One fault log storing the 10 latest minor faults since the last alarm. The information is used to ease repair, tracing of system errors and to provide information for further product improvements. Detailed information in this subject is found in ref [7]. 9.3 Error record An error record is kept in MSC. All error messages that are sent to MSC are kept in the error record. Each message contains information about faulty unit:
- Function block name (Device type)
- Device individual # (In APZ device map)
- Fault type
- Fault code
(Minor, major or serious)
(1-511)
- Cabinet No
- Position No
- HW Product No
- HW REvision State
- HW Serial No
- HW generation
- Product function code
- Revision function code
- System function code
- SW Product number
- SW Revision state 9.4 LED indicators on boards/units All boards and units have LED indications as follows. a Indication LED:s are placed in the upper end of a circuit board and in the upper left corner of a HW unit. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 12 (36) b c leds The following LED:s will be found on all active units:
a b
* Power (Green)
* Error (Red) All units containing DP or SP will also have the following LED:
a
* Status - blocked/deblocked/trafc (Yellow) Led placement:
Green Red Yellow Power Error Status Figure 5 The LEDs location on a circuit board having a DP. Logical description of LED:s:
Power The power LED is always fed from the source that feeds the logic for the er-
ror LED. That is usually the +5V. This gives a safe indication of all different types of errors. Error The functionality will be different depending on the complexity of the product. Generally a lit LED indicates that an error is present. However for units containing DP or SP the following is valid:
When a device is powered up and makes a selftest, the LED will ash. De-
pending on the result, the LED will stay in status lit/not lit. The ashing frequency is 1 Hz. Status The LED will be lit when the device is deblocked and not used for trafc. The LED will be switched off when the device is blocked or in boot state. The LED will be ashing when the device is deblocked and used for trafc or when the device is blocked and being tested. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 13 (36) The ashing frequency is 15Hz. This will give a ickering impression rather than ashing. The duty-cycle of the ashing is generally be 50%, however if the device sup-
ports trafc for more than one carrier/channel, the duty-cycle is progressive, e.g. 20%,40%,60% or 80%, depending on number of carriers/channels in trafc, if four carriers/channels are controlled. The LED will be switched off hardware-wise by the watch dog signal and the LED status in the processor register will be reset. Detailed information about logical descriptions, standardized LED size, exact colors and light intensity is found in ref [5]. 9.5 Indications on cabinets At front of each cabinet two indicators are found: Power-green and Error-red. The indicators are LED:s behind the small window in the front door. The LED:s are controlled from the internal electronics in each cabinet type. The power LED will be lit when power is connected to the cabinet and the er-
ror LED will be lit by any unit/board in the cabinet that has a lit error LED on the board/unit itself. Detailed information in this subject is found in ref [5]. 10 10.1 Base station interfaces Base station external interfaces The following external interfaces are used by the base station hardware:
E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 14 (36) bs external iw Mains
(Future) Batteries
(Future) AC DCB External Power Supply DC Alt 1 RBS884 integrated power Alt 2 RBS884 non integrated power MSC T1 or E1 Base Station Hard Ware AXE-term-
inal V24 BS RF Rx/Tx-
antennas EXT_Alarm EXT_Control EXT_AFS Env Ground External Alarms External Control External AFS
(Future) Environ-
ment Ground-
ing Figure 6 The RBS884 External Interface External interfaces shown by dotted lines in the gure 6 will be added in the future. For more information refer to the Interworking Descriptions listed below DC T1 E1 V24 RF EXT_Alarms EXT_Control EXT_AFS 86/155 19-ANT 244 01 31/155 19-ANT 244 01 77/155 19-ANT 244 01 48/155 19-ANT 244 01 1551-ROF 131 8217 1551-CNZ 212 117 4/155 19-ANT 244 01 47/155 19-ANT 244 01 47/155 19-ANT 244 01 85/155 19-ANT 244 01 10.2 Base station internal interfaces The functional parts are connected via well dened interfaces. This will allow for independent development, functional growth and adaptation to new techniques. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 15 (36) bs internal iw COP CLINK CLINK FAN/CID CLINK FAN/CID MOP Rx Tx ANP FAN/CID Equipment Practice P1 SUP FAN/CID P1 P1 Figure 7 RBS884 Internal Interfaces, physical level. For more information refer to the Interworking Descriptions listed below CLINK FAN/CID P1 Rx Tx bs level 2 iw 26/155 19-ANT 244 01 1551-ROA 117 2042/1 29/155 19-ANT 244 01 83/155 19-ANT 244 01 83/155 19-ANT 244 01 TRAB TRAB_MOP MOP RF CLINK layer 2 ANP CLINK layer 2 COP CLINK layer 2 SUP Figure 8 interwork. RBS884 Internal Interfaces, level 2. Dotted lines shows future For more information refer to the Interworking Descriptions listed below TRAB_MOP RF CLINK layer 2 74/155 19-ANT 244 01 IS-136 27/155 19-ANT 244 01 E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 16 (36) 11 The control structure The control structure follows the CP, RP, DP hierarchy of the APZ, gure 9 a). The BS is controlled by a set of EMRPs located in the BS and connected to the CP of the MSC as a Extension Module Group, EMG. Each EMRP controls a number of devices each one having its own DP, gure 9 b). The gure 9 c) shows the structure of the control part of the BS. The ETBs terminates PCM-links connecting the BS to the MSC. The control link for the EMG is carried on one time slot on the PCM-link and is terminated by the STR. Devices to be controlled are connected to the RTTs via CLINKs, one CLINK to each device. A set of EMRPSs are used to control the devices on load sharing basis. A time switch, TSW, is used to connect control paths from EMRPSs to the devices being controlled. The TSW also routes the trafc data on paths set up between a time slot on an ETB and a device connected to a RTT. The TSW is controlled by a dedicated EMRP. cop a) b) MSC CP EM RP DP MSC CP EMG STC STR BS EMRP DP BS c) PCM-links to MSC Internal ALARMS EMRPS EMRPS EMRPS V24 ETB ETB
#9/16 B P R M E B C V E D B S V E D STR EMRP TSW CLINK CLINK CLINK RTT RTT RTT Units to be controlled Figure 9 The Control structure. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 17 (36) 12 The RF structure The TRX handles uplink radio frequency signals, Rx, from the receive an-
tenna system and transmit downlink radio frequency signals, Tx, to the transmit antenna system. Diversity is used in the uplink direction and the receive path for each branch includes the Multi Coupler, MC, to amplify the received signal and the Power Splitters to distribute equal power level on each TRX connected to the same receive antenna. rcg0 Rx Rx RXBP RXBP MC B MC A Tx DCCTC TXBP MCU PS PS TRX 01 TRX 02 TRX 12 TRX 13 SR TRX 16 DVER TRX 01 TRX 02 TRX 12 TRX 13 SR TRX 16 DVER ATC 01 ATC 02 ATC 12 CTC ATC 01 ATC 02 ATC 12 CTC RFTL Figure 10 The RF structure. Tower mounted ampliers, TMA, can be added to improve the RF sensitivity in the uplink direction. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 18 (36) rcgtma Rx Rx RXBP TMA RXBP RXBP TMA RXBP Tx DCCTC TXBP MCU PS PS TRX 01 TRX 02 TRX 12 TRX 13 SR TRX 16 DVER TRX 01 TRX 02 TRX 12 TRX 13 SR TRX 16 DVER ATC 01 ATC 02 ATC 12 CTC ATC 01 ATC 02 ATC 12 CTC MC B MC A RFTL Figure 11 The RF structure including TMA. Autotuned Filter Combiners, ATC, are used to merge the output power from the TRX:s that shall be connected to the same transmit antenna. The Combiner Tuning Controller, CTC, use the output power measured by the Di-
rectional Coupler Unit CTC, DCCTC, at the antenna feeder connection when tuning each ATC to optimum output. All TRX:s connected to the same receiver antenna system and the same transmit antenna and briged by one Radio Frequency Test Loop, RFTL, is forming a Radio Channel Group, RCG. The RFTL gets two output power sig-
nals from the MCU and transmit RF signal to each TRX via the two multi couplers. 13 Synchronization The RBS884 provides Network Synchronization and Carrier Frequency Stabilization and is prepared for Air Frame Synchronization. 13.1 Network Synchronization Network Synchronization secures error free transmission of data to and from the MCS using buffers and a stable clock. Network Synchronization is handled by the COP. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 19 (36) The clock shall in normal operation be locked to a reference signal provided transparently through the transmission network from the MSC. The reference signal is normally superimposed on one trafc link connecting the BS to the MSC. The buffer is used to equalize short term phase deviations. 13.2 Carrier Frequency Stabilization The radio network requires very accurate carrier frequency. In RBS884 the reference signal used by the Network Synchronization also is used as a Carrier Frequency Reference. Short term phase deviations must be removed from the reference signal. This process is called Carrier Frequency Stabilization and is handled by the COP. To obtain the carrier frequency accuracy the reference signal must be traceable to a source of Stratum 2 level or better. 13.3 Air Frame Sync, (Future function) AFS, when used, will synchronize all air frames transmitted from the BS. Then all frames will be transmitted phase aligned in the air. AFS is a future function. The AFS shall be generated by the future module TIM. The AFS will be distributed to each TRX in the backplane of each TCB. The TCB will be connected in a daisy chain fashion via the DCON board. A termination will be needed in the end of the chain. E refdistr Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 20 (36) SYNC RFTL TIM ANPC1 SYNC RFTL RFTL ANPC2 DCON TRX TRX DCON TRX TRX DCON TRX TRX TCB TCB TCB DCON TRX TRX DCON TRX TRX DCON TRX TRX TCB TCB TCB T Max 64 TRX T Max 64 TRX T Max 64 TRX Figure 12 The Air Frame Sync distribution The interface SYNC is part of the mechanic of the magazine and has connectors for distributing the AFS from ANPC1 to ANPC2. 14 Power supply and power distribution The support part (SUP) provides DC of +24 Volts to all equipment on the site. The DC is produced redundantly by applying a N+1 conguration of external, internal in future, AC/DC converters that are connected in parallel. Users are connected via fuse and low ohmic distribution. Decentralized DC/DC conversion is adopted for users. That is, generally boards and modules has internal, on board DC/DC, converters for required voltages. Generally all parts that are vital for operation has redundant power feeding to increase availability for base station operation. The support part also hosts the optional battery backup. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 21 (36) 14.1 RBS884 Non Integrated Power Non Integrated Power means AC/DC and battery equipment having other physical and mechanical structure than the RBS884 Equipment Practice and is also not an integrated part of the RBS884 control and supervision functions. With Non Integrated Power the SUP includes only the Power Distribution sub-
module, POWD, having connectors and circuit breakers for 32 P1 interfaces. DC, +24V, must be provided to POWD from an external source. The external source shall be supervised via external alarms. 14.2 RBS884 Integrated Power (Future) With Integrated Power the SUP consists of a number of Power Unit Cabinets
(PUC), Battery Interconnection Cabinets (BIC) and a battery package. The rst BIC has a CLINK connection to the CRI for control and alarm purpose. The PUC includes rectiers, a distribution part having connectors and circuit breakers for 12 users (replacing the POWD) and connection to the BIC. The PUC:s are connected to a Battery Interconnection Cabinet (BIC). Up to 4 PUC:s can be connected to one BIC. pow Users Users Users Users AC mains PUC PUC PUC PUC BIC Further BIC:s 1:st half 2:nd half Battery package Figure 13 Integrated power Redundancy structure General 15 15.1 The redundancy structure is based on duplication of vital units, N+1 redundancy and the backup functionality. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 22 (36) A faulty unit without redundancy will always reduce the service capability. With the backup function vital trafc functions such as CC, DCC, SR and DVER can be maintained. The most critical part is the CRI terminating the transmission line to the MSC and the control link. The CRI is also controlling the entire BS. 15.1.1 One single CRI In a small site, controlled by one CRI, the CRI is critical. In the gure 14 any single fault in the shaded parts can be bypassed either due to built in redundancy or by using back up unit or n+1 redundancy. Note that the gure is a logical gure and shows the units that must be oper-
ating in order to have a control path to the TRX and in order to have a speech path to the TRX. The gure does not show the exact interconnections and order in each path. For proper function the backup unit must be controlled by an other EMRPS and via an other RTT than the unit it will back up. A fault in the ETB or in the TSW will stop the entire BS. RED_ONECRI Control path DC/DC FAN ETB STR DC/DC FAN Redundance STR ETB Redundance
(optional) n + 1 EMRPS TSW RTT TRX N + 1 Back up unit VC DVC CC DCC SR VER Speech path DC/DC FAN DC/DC FAN Redundance One single CRI ETB TSW RTT TRX N + 1 VC DVC Figure 14 One CRI, system structure, logically 15.1.2 Two or more CRI With two or more CRI all single faults can be bypassed in the control path. Vital trafc functions such as CC, DCC, SR and DVER can be maintained using the backup functionality. In the gure 15 any single fault in the shaded parts can be bypassed either due to built in redundancy or by using back up unit or n+1 redundancy. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 23 (36) For proper function the backup unit must be controlled by an other CRI than the unit it will back up. redtwocri Control path DC/DC FAN DC/DC FAN Redundance DC/DC FAN DC/DC FAN Redundance Speech path DC/DC FAN DC/DC FAN Redundance Two or more CRI ETB STR TSW n + 1 EMRPS RTT TRX N + 1 Back up unit VC DVC CC DCC SR VER ETB STR Redundance ETB TSW RTT TRX N + 1 VC DVC Figure 15 Two CRIs, system structure, logically The speech path has no redundancy in the ETB and TSW. A fault in any of these will reduce the trafc capability proportional to lost trafc channels. 15.2 CRI The CRI redundancy is based on duplication of vital units and N+1 redundancy. The power is distributed redundantly and a single DC/DC converter failure will not affect the magazine. The fan unit contains two fans where one fan can keep the cabinet within permitted temperature range. The EMRPS:s can be congured in a N+1 fashion which means that if any of the active EMRPS:s fails, the stand by EMRPS can take over the task. Changing to the redundant EMRPS must be handled manually. The redundant EMRPS is supervised by APZ. Reconguration has to be done manually from the MSC. The TSW and the EMRP cannot be duplicated. The RTT cannot be duplicated. E 15.3 TCB Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 24 (36) As each carrier can support any of the possible system frequencies, a N+1 fashion can be deployed for the TRX:s. The multi function TRX also makes it possible to use the stand by TRX (or any of the TRX:s working as a voice channel) as backup unit for the functions ACC, DCC, DVER or SR. Device/function switching is performed automatically by the MTS in the MSC, to predened redundant HW-unit. The fan unit contains two fans where one fan can keep the cabinet within permitted temperature range during otherwise normal conditions. The TRX is fed with power in groups of four, so the maximum impact of a fuse failure is on four carriers. 15.4 ATCC The ATC:s can be congured in a N+1 fashion along with TRX, as each ATC can tune to any of the system frequencies. The fan unit, integrated in the CTC, contains two fans where one fan can keep the cabinet within permitted temperature range. A CTC can not be duplicated. A CTC failure will reduce the functionality. The backup function can be blocked. The ATC:s will keep their current tuning but will not be able to change frequency or compensate for temperature changes. The ATCC cabinet is fed redundantly with respect of DC power supply. 15.5 ANPC Each cell has diversity reception of radio signals. Hence there are two multi-
couplers per cell and at a MC failure the system will continue to work with degraded performance. An ALM failure will not affect operation but it will reduce the supervision of internal BS errors and disables all external alarm and control possibilities. A RFTL failure will result in reduced supervision functionality for one RCG. The ANPC is fed redundantly with respect of DC power supply. The fan redundancy is equivalent to CRI. 15.6 Power system (Future) With RBS884 integrated power the AC/DC rectiers will congured in a N+1 fashion. Fans in PUC will be redundant. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 25 (36) 16 CO-siting The RBS884 can be co-sited with the RBS882D. Co-sited means that the RBS884 and the RBS882D shares the Tx and Rx antennas and are controlled by the same EMG. The antenna system will be "owned" by the RBS884. The Rx signal is for-
warded from the MC of the RBS884 to the MC of the RBS882D, refer to the gure 16. The Tx signals are joined after the combiners of each system and fed to the Tx antenna through the TxBP and MCU of the RBS884. To share the same EMG the EMRPB of the control part of the RBS884 and the control part of the RBS882D must be connected. The control parts of the RBS884 and the RBS882D must independent of each other get the sync reference directly from the MCS. Thus each one requires a PCM-link to the MCS. cosite Tx Rx Rx RBS882D RBS884 RF MCU RFTL RBS884 MC PMU TxBP CLINK
+22,6dB
+1dB RBS882 Combiner MCU T-connector CRI RBS884 Combiner RBS884 PSP 1:16 DTRM
+5,2 dB RBS882D MC CT
"COP"
ERI/TRI STR TRX
+5,2 dB COP EMRPB PCM-link to MSC PCM-link to MSC Figure 16 Co-siting of RBS884 and RBS882D E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 26 (36) The details of the interconnection of the RF parts are described in:
RF 89/155 19-ANT 244 01 CO-siting ANP, RBS882 and RBS884 17 17.1 Capacity The CRI A BS can be a omni or a two or three sector site. Minimum one RCG is required for a sector. The CRI is common for all sectors. The CRI shall have balance between EMRPS and RTT. The load on the EM-
RPS is mainly the control of the TRX:s. One EMRPS is assumed to control up to 4 - 5 TRXs. Remaining equipment is in the ANP and can be spread out evenly on a number of EMRPS and adding little load to the EMRPS. control T1 or E1 to the MSC control link control link CRI CELL A CELL B CELL C RCG TRX TRX TRX CTC RFTL ALM RCG TRX TRX TRX CTC RFTL ALM RCG TRX TRX TRX CTC RFTL ALM Figure 17 A three sector site A good balance is 7 + 1 EMRPS and 6 RTT controlling from 4*7 = 28 TRXs up to 5*7=35 TRXs if the extra EMRPS is used as a redundant unit. If all EM-
RPSs are active units then from 4*8 = 32 TRXs up to 5*8=40 TRXs can be controlled. RTT capacity not used by TRXs will be left over to ANP equipments. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 27 (36) In a three sector site, dual band, there will be at least 1 SR, 1 DVER and 1 CC per sector or totally 9 TRXs not requiring any speech path to the MSC. With one T1 link to the MSC 23 DS0s are available and 23+9 = 32 TRXs shall be controlled by the CRI. With one E1 link to the MSC 30 DS0s are available and 30+9 = 39 TRXs shall be controlled by the CRI. In a three sector site each sector has 1 RFTL and 1 CTC for the rst 11 TRXs carrying voice or data and 2 CTCs if there are more TRXs. The ANP also includes 2 ALMs. Then 8 - 11 CLINKS are required. Then in a three sector site having up to 8 (one T1) or 10 (one E1) TRXs per sector carrying voice takes 40 and 47 out of 48 CLINKS respectively. For more capacity a second PCM-links is required. However only a small part of added DS0s can be used due to limited number of available CLINKs. In most cases 2 PCM-links means 2 CRIs. This is also good from reliable reasons too. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 28 (36) 17.2 The RCG Rx Rx rcgfull RXBP RXBP MC MC PS PS PS PS TRX 01 TRX 02 TRX 08 TRX 09 TRX 16 TRX 01 TRX 02 TRX 12 TRX 09 TRX 16 TRX 01 TRX 02 TRX 08 TRX 09 TRX 16 TRX 01 TRX 02 TRX 12 TRX 13 TRX 16 Tx Tx DCCTC TXBP MCU ATC 01 ATC 02 ATC 08 ATC 09 ATC 16 CTC ATC 17 ATC 18 ATC 24 ATC 25 CTC ATC 32 CTC DCCTC TXBP MCU ATC 01 ATC 02 ATC 08 ATC 09 ATC 16 CTC ATC 17 ATC 18 ATC 24 ATC 25 CTC ATC 32 CTC RFTL Figure 18 Maximum RCG conguration. The RCG can be expanded to 64 TRX:s on the Rx antenna system. To match the Rx side two Tx antennas are required each one serving a group of 32 TRX:s. A three sector site having one full RCG in each sector has totally 3*64 = 192 TRX:s. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 29 (36) Rx Rx rcgfultmal RXBP TMA RXBP RXBP TMA RXBP MC MC PS PS PS PS TRX 01 TRX 02 TRX 08 TRX 09 TRX 16 TRX 01 TRX 02 TRX 12 TRX 09 TRX 16 TRX 01 TRX 02 TRX 08 TRX 09 TRX 16 TRX 01 TRX 02 TRX 12 TRX 13 TRX 16 Tx Tx DCCTC TXBP MCU ATC 01 ATC 02 ATC 08 ATC 09 ATC 16 CTC ATC 17 ATC 18 ATC 24 ATC 25 CTC ATC 32 CTC DCCTC TXBP MCU ATC 01 ATC 02 ATC 08 ATC 09 ATC 16 CTC ATC 17 ATC 18 ATC 24 ATC 25 CTC ATC 32 CTC RFTL Figure 19 Maximum RCG conguration with the optional TMA. A set of four CRI should physically address this site provided each EMRPS have capacity to control 8 TRXs. 17.3 The EMG An EMG can address up to 32 EMRP. A CRI having 7+1 EMRPS takes 9 addresses since there is an EMRP controlling the TSW and the ETB:s. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 30 (36) There can be up to 4 CRI in one EMG. The total capacity of the EMG de-
pends on the capacity of each EMRPS. To control 192 TRXs one EMRPS must control 8 TRXs. CONTROL2 control link control link T1 or E1 to the MSC RCG CELL A CRI RCG CELL B CELL C RCG Figure 20 Maximum conguration of 1 EMG
(Note) The EMG is associated with one control link taking one DS0 of the PCM-link. The capacity is limited and will dene the number of TRX:s that can be controlled by one EMG One site can be divided on more than one EMG if the number of TRX:s exceeds the capacity of one EMG. 18 HW support for Trafc functions There are no specic trafc functions related to the RBS884 family. Functions supported is equivalent to RBS882 and RBS882D. The HW is designed to allow any channel function in any EMRPS or TRX, i.e. free allocation Possibilities to assign backup units is thus maximized. The HW is not prepared for non-IS-54 characteristics like dynamic (time-slot) BS power regulation or CDMA. Some HW must be replaced to allow this. The HW is prepared for Air Frame Sync, i.e. all TRXs can operate at the frame timing (in digital mode). RBS884 family is designed to support CDPD modulation (with SW reload). E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 31 (36) 19 HW support for Standard O&M functions All functional descriptions in this document are limited to the HW support, pri-
marily for functions without system support, i.e. where there is no other function documentation. 19.1 Device recovery The recovery intends to lter out occasional, temporary, errors ("false alarm"). If a device reports a serious fault the system will respond with a blocking or-
der. After nine minutes the system will try to reset and start the device again. If a new serious fault is received within six minutes, the device will be blocked again and no further attempts to recover will be performed. 19.2 Back-up of CC/DCCH/SR/VER If there is a malfunction in the equipment providing the CC function, the sys-
tem (meaning MTS) is automatically moving the CC function to a predened backup equipment. The same support is available for SR (as in earlier packages), VER and DCCH backup. All backup functions are "owned" by MTS, MBS only supports these functions. The MTS function only allows reconguration from the
"essential" channel functions to VC/DTC. The MBS architecture, and RBS884 HW, supports exible allocation of backup channel to any device. This enables exible HW upgrading, where different units may be merged, as the HW is rationalized. The backup unit should be chosen so that original and backup units share as little HW as possible, maximizing the system availability. 19.3 Test and monitoring outlets There is only one monitoring outlet, a measurement coupler per Tx antenna connection. The coupler is the MCU to be used by RFTL. 19.4 Base Station Test Interface (BSTI) The possibility to connect a PC to the EMRPS in order to log and insert signals for test purposes. Not to be used by customers. 19.5 CSU functions The RBS884 requires external CSU. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 32 (36) 19.6 Voice line characteristics Both analog and digital voice channels have selection of A- or u-law PCM coding, voice level adjustment (up- and downlink separately). In digital mode the TRAB makes the coding. In analog mode the TRX makes the coding. 19.7 Hot Repair All units are capable of being extracted/inserted in live magazines, without being damaged or other units being disturbed electrically. Normal blocking/deblocking procedures should be used to avoid trafc disturbances. 20 20.1 HW support for Optional O&M functions RF testloop with RFTL The HW supports the following function, but there is no system support yet. The RFTL can be used to test the Tx and Rx RF-paths. A TRX is ordered to transmit a predened modulated carrier. RFTL picks up the signal via the measuring coupler unit. The signal is mixed and transferred to the MS trans-
mitting band and fed out on the Rx branches via the MCU. Any TRX can then be ordered to measure the signal in order to check TRX and RF-path functions. 20.2 Control outputs With an ALM unit installed output control, a future functionality, can be provided. Up to 8 output control ports are available on the ALM unit. Each output provides a closed loop when activated. The ports are controlled by manual command outputcontrol Activation Output Figure 21 The output control closed loop Refer to 47/155 19-ANT 244 01, ALM interwork description. E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 33 (36) 20.3 SW and HW information The HW supports the following function, but there is no system support yet. The function provides a printout of base station equipment. Lists can potentially be produced on MSC, site or device level. The printout contain information about:
- SITE
- CABINET_NUMBER
- POSITION_NUMBER
- HW_PRODUCT_NUMBER
- HW_REVISION
- HW_SERIAL_NUMBER
- PRODUCT_FUNCTION_CODE
- REVISION_FUNCTION_CODE
- SYSTEM_FUNCTION_CODE
- SW_PRODUCT_NUMBER
- SW_REVISION 21 References
[1]. 10/1056-ANT 244 01 EMC Requirements
[2]. 1/1531-ANT 244 02 Grounding Principles
[3]. 11/1056-ANT 244 01 Environment Requirements
[4]. 12/1056-ANT 244 01 Safety Requirements
[5]
10/10260-ANT 244 01 Product characteristics Indicators, marking and numbering.
[6]
14/10260-ANT 244 01 Marking of field exchangeable units
[7]
7/10260-ANT 244 01 Storage of information in HW and SW Product and function E 22 22.1 Vocabulary Abbreviations Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 34 (36) related info in HW and SW and Event log. ACC AFS ALM ANP ANPC ATC ATCC AVC BFU BIC BS COMB CID CLINK COP CRI CTC DCC DC-CTC DCON DEVCB DEVSB DP DS0 DTC DVER EMG EMRP EMRPB EMRPS ETB ETC GS ICF LED MBS MC MOP MSC NI PCU Analog Control Channel Air Frame Synchronization Alarm Module Antenna Near Part ANP complementary equipment Cabinet Auto Tuned Combiner/Cavity ATC and CTC Cabinet Analog Voice Channel Battery Fuse Unit Battery Interconnection Cabinet Base Station Combiner Cabinet Identity switch Control LINK Control Part Control and Radio Interface Combiner Tuning Controller Digital Control Channel Directional Coupler CTC Data Connection board (In TCB) DEVice Control Bus DEVice Speech Bus Device Processor (A Device on the DEVCB or eq.) One 64 kbit channel (time slot on a PCM connection) Digital Traffic Channel Digital verification function Extension Module Group Extension Module Regional Processor Extension Module Regional Processor Bus EMRP Speech bus interface Exchange Terminal Board Exchange Terminal Central Group Selector Inter Connection Fuse unit Light Emitting Diode Mobile Base station Subsystem Multi Coupler Modem Part Mobile services Switching Center Network Interface Power Control Unit E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 35 (36) PS PUC RBS RCG RF RFBP RFTL RP RSSI RTT Rx RXBP SR STC STR SUP T1 TCB TIM TRA TRX TSW Tx TXBP VER VSWR Power Splitter Power Unit Cabinet Radio Base Station Radio Channel Group Radio Frequency RF Backplane (in TCB) Radio Frequency Test Loop Regional Processor Receive Signal Strength Indicator Radio Transceiver Terminal Radio Frequency receiver path Receiver Band Pass filter Signal strength receiver function Signaling Terminal Central Signaling Terminal Remote Support Part American standard for 1.5 Mbit PCM lines Transceiver Cabinet TIming Module Transcoder Dual mode transceiver device Time Switch Radio Frequency transmitter path Transmitter Band Pass filter Verification Module Voltage Standing Wave Ratio 22.2 Terminology AFS CLINK CSU DSI DS0 An Air Frame Synchronization signal used to synchronize all TRX:s in one RBS884. The general communication interface within the RBS 884 base station. A 2.048 Mbit interface carrying 32 independent 64 kbit channels (DS0:s) which are always numbered 0-31. Customer Services Unit includes functions separating the transmission provider equipment from the customer equipment.
(Digital Signal level 1, 1.544 kb/s) The metallic interface between a Carrier and a Customer installation. 4-Wire interface of 1.544 Mbit/s.
(Digital Signal level 0, 64 kb/s) One 64 kbit channel on a T1 connection. (Also used as the name for a 64 kbit channel on a CLINK.) E Description Datum Date 1996-08-02 Rev C Dokumentnr Documentno 8/1551-ANT 244 01 Uen 36 (36) E1 The European standard for 2.048 Mbit PCM connection. Car-
ries 32 independent 64 kbit channels (DS0:s) which are always numbered 0-31 EXT_AFS An Air Frame Synchronization signal from an external air frame sync source. Switching equipment acting as concentrator/distribution point for transmission lines to subordinated equipment. HUB RCG Radio Cabinet Group A group of transceivers/combiners connected to the same re-
ceiver and transmitter antenna system and thus also using the same RFTL. RBS884 RBS884 represents the Macro version of the RBS884 family. STRATUM Classication of clock characteristic in a hierarchy of clocks op-
erating in a master slave relationship. Stratum 1 has the highest accuracy and performances. T1
+24V The American standard for 1.544 Mbit PCM connection. Car-
ries 24 independent 64 kbit channels (DS0:s) which are always numbered 1-24.
+24 V is used in this document as a general term for the un-
regulated DC power distributed from the support part to all cabinets. The nominal voltage level is +27.2 V. Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 1(27) File CMS88, MBS DESCRIPTION RBS 884 Abstract This document contains a description of the RBS 884 Radio station. RBS 884 is commonly called the Macro base station. Application Introduction to RBS 884 (HRB 104 11). Supplementary document Approved DQI status: Exited <13/00641/FCP 103 749 Uen>
1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 2 File CMS88, MBS TABLE OF CONTENTS 1 2 2.1 2.2 2.3 2.4 2.5 2.6 3 3.1 3.2 3.3 3.4 3.5 4 5 6 7 GENERAL MACRO BASE STATION PRODUCTS CABINETS CONTROL PART PRODUCTS MODEM PART PRODUCTS ANTENNA NEAR PART PRODUCTS SUPPORT AND INTERCONNECT PART PRODUCTS RBS 884 MACRO USER LIBRARY INTERCONNECTION BASICS CLINK RECEIVE PATH TRANSMIT PATH POWER EXTERNAL INTERFACES CONFIGURATIONS ACRONYMS AND ABBREVIATIONS REVISION INFORMATION REFERENCES 3 4 4 4 5 8 14 15 16 16 16 19 20 20 21 24 25 26 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 3 File CMS88, MBS 1 GENERAL The Macro base station, RBS 884, is a product in the CMS 88 product family and belongs to the subsystem MBS (ANT 244 01). The Macro base station is designed to operate in cellular DAMPS(AMPS) systems. It is a configurable product with a variation of possibilities, features and options. This document gives a short description of the products in the Macro base station (HRB 104 11). The document is a complement to 8/1551ANT 244 01 (ref 1). Functional information such as eg., control structure, RF structure, base station interfaces, basic fault handling, synchronization, cositing, HW support for traffic functions etc., is found there. Technical data of the Macro base station is given in the Product data document ref (15). For a HW and SW introduction to MBS consult ref (2) and
(3). 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 4 File CMS88, MBS 2 2.1 MACRO BASE STATION PRODUCTS CABINETS The RBS 884 cabinets are based on the equipment practice for BYB 401 001. A base station is built with 5 different types of cabinets, CRI, TCB, ANPC, ATCC, and POWD. With these, 12 standard configurations have been designed. Each configuration can be built in modular steps. Common to all cabinets is that they have a CID unit. With this the position of the cabinet in the configuration can be set. A number indicates rack position and a letter indicates the row in the rack (see ref 16 to 21). The CID can be read from the MSC
(exception the POWDCID). 2.2 CONTROL PART PRODUCTS 2.2.1 CRI The Control and Radio Interface (CRI) handles communication with the MSC. It is involved in radio traffic control and controls devices such as the TRX device, the CTC device etc. It has an interface to the transmission network (PCM), a time switch for setting up semi permanent paths, and an interface to the devices
(CLINK). The clocks in the CRI are synchronized to the network. Incoming clocks are filtered from jitter and wander and are also used as reference frequency for the carriers. Four variants of CRIs exist. BFE 401 74/1 Fully equipped CRI for T1, BFE 401 74/2 Half equipped CRI for T1, BFE 401 74/3 Fully equipped CRI for E1, and BFE 401 74/4 Half equipped CRI for E1. The fully equipped variants contain an ETB, an STR, an EMRP, a RITSW, 8 EMRPSs, 6 RTTs , 2 DC/DCs and an internal fan. The half equipped version contains 3 EMRPSs and 3 RTTs less. The configurations of the full and half cabinets are shown in ref. (16). (It is shown in all configuration descriptions (16) to 21).) For more information about the CRI consult ref. (6) and the PCB product documentation. The control stucture of a base station and more information on the synchronization is given in (1). 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 5 File CMS88, MBS 2.2.2 MAGAZINE EXPANSION The Expansion kit (1/BFE 401 74/1) contains 3 RTTs and 3 EMRPSs boards. With this kit a half equipped CRI can be expanded to a full. 2.2.3 SET OF MATERIALS The EMRP Address plugs (from 1 to 9) are installed in the factory. When a second and a third CRI is installed at a site they must be replaced with new address plugs
(10 to 18). The product number of the second set is NTM 201 702/1, and the product number of the third set is NTM 201 702/2. 2.2.4 ETB The ETB/ETP (ROF 137 78 46/1) and ETB/24 (ROF 137 7892/1) are used to interface the transmission network. ETB/ETP is used for E1 and ETB/24 is used for T1. In some configurations an additional ETB is necessary in the second CRI see ref. (7). 2.3 MODEM PART PRODUCTS 2.3.1 TCB 2.3.1.1 General The Tranceiver cabinet (BFE 401 66/1) is produced equipped with radio backplane (PSPB), DCON, PFCON and internal fans. The cabinet is equipped with 10 W TRXs or 30 W TRXs and a PSP board at installation. Unused TRX positions must be equipped with RMUs (2.3.3) to ensure proper cooling and EMCshielding. The Tranceiver cabinet (BFE 401 66/2) is used for 50 W base stations. It is identical to BFE 401 66/1 except that it has an other type of fan unit to provide increased cooling capacity. The radio backplane in the TCB is fed with incoming received signals via PSPs from the multicouplers (MCA and MCB). (The type of PSP depends on the configuration, see 2.4.1.) Then the radio backplane splits these received signals and connects them to TRXs in the TCB. Incoming signals are connected in a similar pattern as the CLINK signals. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 6 File CMS88, MBS TX signals are connected from each TRX front to the ATCC. Power is connected from POWD to PFCON. It is distributed in 4 groups to TRXs in board positions (2, 3, 4, 5), (6, 7, 8, 9), (10, 11, 12, 13), and (14, 15, 16, 17). Note that board position numbers are different from TRX slot numbers. TRX 1 in a 10 W configuration is positioned in board position 2, TRX 2 is positioned in board position 3, etc. The 30 W and 50 W TRXs are twice as wide as the 10 W TRXs i.e., they need two board positions in the TCB. TRX 1 in a 30 W and a 50 W configuration is positioned in board position 3, TRX 2 is positioned in board position 5, etc. For more information on the TCB see ref. (8). For more information on the configurations consult ref. (16) to
(21). 2.3.1.2 10 W configurations CLINKs are connected from the RTT boards in the CRI to the DCON boards. In the 10 W configuration the signals are distributed to TRX slots in the following order (2, 6, 10, 14), (1, 5, 9, 13) and (3, 7, 11, 14). In the designed configurations the TCB is equipped with 10 W TRXs in the following order (TRX slots) (2, 6, 10, 14), (1, 5, 9, 13) and (3, 7, 11, 15). The first TCB in a sector is equipped with measurement receivers (VER and SR). The measurement receivers are allocated in TRX slots 12 and 16. TRXs in slots 2 and 6 in the first TCB in a cell are allocated for ACC and DCCH. If T1 is used, slot 4 and 8 has to be equipped with RMUs. If E1 is used, even slot 4 and 8 can be equipped with TRXs. For further information about optimization of a PCM link for E1, see (30). 2.3.1.3 30 W configurations CLINKs are connected from the RTT boards in the CRI to the DCON boards. In the 30 W configurations the signals are distributed to TRX slots in the following order (1, 3, 5, 7) and (2, 4, 6, 8). In the designed configurations the TCB is equipped with 30 W TRXs in TRX slots in the following order, (1, 3, 5, 7) first and then (2, 4, 6, 8). The first TCB in a sector is equipped with measurement receivers (VER and SR). The measurement receivers are allocated in TRX slots 6 and 8. TRXs in slots 1 and 3 in the first TCB in 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 7 File CMS88, MBS a cell are allocated for ACC and DCCH. If T1 is used and it is a sectorized cell, not all of the TRX slots can be used (it depends on the size of the cell and the number of carriers). The unused slots has to be equipped with RMUs. If E1 is used, all slots can be equipped with TRXs. For further information about optimization of a PCM link for E1, see (30). 2.3.1.4 50 W configurations The connections of CLINKS in 50 W configurations are made in the same way as in 30 W configurations. The TCBs in the 50 W configurations are equipped in the same way as in the 30 W configurations. 2.3.2 TRX Three variants of tranceivers are used in the Macro base stations, TRX (KRC 121 10/2), 30 W TRX (KRC 121 10/3) and 50 W TRX (KRC 121 04/4) The TRX can modulate/demodulate both FM and p /4DQPSK RFsignals. Consequently all six IS136 channel functions can be handled by the TRX. These functions are:
Analog voice channel (AVC) Analog control channel (CC) Signal strength receiver (SR) Digital traffic channel (DTC) Digital control channel (DCCH) Verification receiver (VER) In digital traffic the TRX carrier can convey 3 DTCs or 1 DCCH and 2 DTCs. All other channel functions require one TRX per function. The connected CLINK (2 Mbit/s) has two duplex 64 kbit/s channels (timeslots) connected. One is for control and the other is for speech. The control of the TRX is done by the EMRPS in the CRI. For more information on the TRX see (9). 2.3.3 Radio Matching Unit (RMU) A RMU (SXK 107 4011/1) must be mounted in not used TRX slots of the cabinet. This is to ensure cooling of the TRXs in service and EMC shielding. Two RMUs are used to cover the space of 30 W and 50 W TRXs. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 8 File CMS88, MBS 2.4 ANTENNA NEAR PART PRODUCTS 2.4.1 PSP Four different kinds of Power splitter boards (or Antenna distributors) are used in the current configurations. These are PSP 16 (KRY 121 53/1), PSP 4
(KRY 121 53/3), PSP 8/2 (KRY 121 53/6) and PSP 2/2 (KRY 121 53/5). The PSPs are all connected to two receive branches. PSP 16 splits each branch in 4 with an approximate attenuation of 7 dB. All four outputs are connected to the PSPB in the TCB. PSP 16 is used in 10 W configurations. PSP 4 connects 4 signals from each branch to the PSPB with an attenuator. The attenuation is 7 dB. PSP 4 is used in 10 W, 30 W and 50 W configurations. PSP 8/2 splits each branch in 4 with an approximate attenuation of 7 dB. Two outputs are connected to the PSPB in the TCB. The other two are connected to a PSP 2/2 in another TCB. PSP 8/2 is used in 30 W and 50 W configurations. PSP 2/2 connects 4 signals from each branch to PSPB with an approximate attenation of 1 dB. PSP 2/2 is used in 30 W and 50 W configurations. 2.4.2 ATCC 2.4.2.1 ATCC, GENERAL The TRX transmitter outputs are connected to the ATCs. A single RF output from the ATCC is connected to the TXBP
(and MCU), which in the 10 W and 30 W combiner versions is located in the ANPC, and then to the antenna. In the 50 W versions the RF output is connected to the TXBP
(and MCU), which in this case is located in the ATCC, and then to the antenna. The ATCs are controlled by the CTC which is controlled by the system through the CRI. A CLINK is connected from an RTT to the CTC. Forward power is measured with the DCCTC and are used by the CTC to tune the combiners. Tuning time at a frequency change is between 2 and 3 seconds. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 9 File CMS88, MBS 2.4.2.2 ATCC 10 W and 30 W Four versions of AutoTuned Combiner Cabinets exist for the 10 and 30 W configurations. Two of them, ATCC1 (BFE 401 017/1) and ATCC2 (BFE 401 019/1), are old versions and are not orderable any more. The two new versions are ATCC1 (BFE 401 058/1) and ATCC2 (BFE 401 059/1). An ATCC1 is delivered with an ATCquad, a CTC, a DCCTC, and a fan. The ATC quad consists of 4 ceramic combiners assembled together. The combiner is designed for a maximum input power of 30 W (44.8 dBm) and a minimum channel spacing of 270 kHz. The ATCC can house 3 ATC quads. Hence two additional quads can be installed. The ATCC2 is similar to an ATCC1 but does not contain a DCCTC. Only one DCCTC is used per TX antenna. Two cabinets are connected together side by side. The combiner outputs are connected together in a Tjunction before the DCCTC in ATCC1. For more information see ref. (10), (11), (28) and (29). 2.4.2.3 ATCC, 50 W Three versions of Autotuned combiner cabinets exist for the 50 W configuration, ATCC1 (BFE 401 050/1), ATCC2
(BFE 401 050/2) and ATCC3 (BFE 401 052/1). A basic ATCC1 is delivered with an ATCquad, one CTC and a TXBP (including the MCU) . The ATCquad consists of 4 ceramic combiners assembled together. The combiner is designed for a maximum input power of 56 W (47.5 dBm) and a minimum channel spacing of 270 kHz. 8 carriers can be connected to a fully equipped ATCC1. ATCC1 contains maximum one CTCs which can control 16 combiner filters and one TXBP. A basic ATCC2 is delivered with an ATCquad and one CTC. 12 carriers can be connected to a fully equipped ATCC2. ATCC2 contains maximum one CTC which can control 16 combiner filters. ATCC1 and ATCC2 are connected together side by side. The combiner outputs are connected together with a jumper before the TXBP in ATCC1. A basic ATCC3 is delivered with one ATCquad, one CTC and one TXBP. 32 carriers can be connected to a fully equipped ATCC3. ATCC3 contains maximum two CTCs which can control 16 combiner filters. The ATCC3 is precabled for 32 carriers at delivery. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 10 File CMS88, MBS ATCC3 is required for base stations with more than 20 carriers and recommended if the initial installation of the base station exceeds or equals 16 carriers. For more information see ref. (23) and (24). 2.4.3 EXTENSION KIT ATCC 2.4.3.1 Extension kit 10 W and 30 W The extension kit (BFZ 101 19/1) for the old version of the combiners consists of an ATCquad and two short Ulinks. The ATCquad is installed in the ATCC. The extension kit (BFZ 101 32) consists of an ATCquad and two short Ulinks. The ATCquad is installed in the ATCC. For information on installation procedures consult (12). 2.4.3.2 Extension kit 50 W The extension kit (BFZ 101 32) consists of an ATCquad and two short Ulinks. The ATCquad is installed in the ATCC. The extension kit (BFZ 101 31) consists of a CTC and cabling. The CTC is installed in the ATCC. For information on installation procedures consult (12). 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 11 File CMS88, MBS 2.4.4 ANPC 2.4.4.1 ANPC, GENERAL There are five versions of the ANP complimentary equipment cabinet. For the 10 W and 30 W configurations they are ANPC1 (BFE 401 022/1), ANPC2 (BFE 401 023/1) and ANPC3 (BFE 401 022/2) and for the 50 W configuration they are ANPC1 (BFE 401 037/1) and ANPC2 (BFE 401 038/1). 2.4.4.1.1 ANPC Rx path The Rx inputs to the ANPC are connected to the antenna feeders. The received signal is first filtered in the Receiver bandpass filter (RXBP). The RXBP filters the signal in the AMPS receive band (824 MHz to 849 MHz). Then it is amplified in the multicoupler (MCA and MCB, one for each bransch). From the multicoupler output it is connected to the PSPs in the TCB. The multicoupler has capacity to feed 4 PSPs. The optional RFTL is connected to each multicoupler and can generate a signal to be received by each TRX. The purpose is test and calibration. 2.4.4.1.2 ANPC Tx path The Tx input is connected from the ATCC output. The TXBP in the Tx bransch attenuates out of band emission
(869894 MHz). After this filtering the Tx signal is connected to the Measuring Coupler Unit (MCU). The output from the MCU is connected to the antenna feeder. The MCU gives the reflected and the forward power. The MCU has different outputs for 10 W (42 dB), 30 W (47 dB) and 50 W (47 dB) operation. The outputs are connected to the RFTL (the optional RFTL measures the reflected and the forward power given by the MCU). An RFinstrument could possibly be connected to any of these outputs for test purposes. TXBP and MCU are located in the ANPC only for the 10 W and 30 W configurations, in the 50 W configuration they are located in the ATCC. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 12 File CMS88, MBS 2.4.4.1.3 ANPC supervision ANPC1, 2 and 3 are all equipped with one ALM board each. The ALM board has 16 internal alarm inputs, 32 external alarm inputs and 8 control outputs. (In the initial release of the MBS SW there is no support for the outputs.) It is controlled over the CLINK by the CRI. ANPC1 and 3 have two reserved slots for TIM (covered with blind plates). (Synchronization with TIM will be implemented in the next release of MBS.) 2.4.4.2 ANPC, 10 W, 30 W The ANPC for 10 W and 30 W houses units for the receive path, the transmit path, supervision of both TX and RX paths and alarm. ANPC1 and ANPC3 *) for the 10 and 30W configurations host units for one cell, and ANPC2 hosts units for two additional cells. Since receiver diversity is implemented in RBS 884 the ANPC1 and ANPC3 supports two Rx antennas and ANPC2 supports four Rx antennas (two Rx antennas per cell), and each receive path has one RXBP filter. After the Rx signal has been filtered it is amplified in the Multicoupler (MCA and MCB, one for each bransch) The gain is approximately 23 dB. (A 1 dB output also exists and is intended to be used when RBS 884 is cosited with RBS 882, see (1).). ANPC1 supports one Tx antenna, ANPC2 supports two Tx antennas (one per cell) and ANPC3 also supports two Tx antennas (but only serves one cell). Each Tx path has one TXBP filter and one MCU. The RFTL is connected to the input of the multicouplers and to the output of the MCU, different output pairs depending on 10 W or 30 W. The cabinet also houses a Power connection board (POC) and a fan unit. For more information about the ANPCs for the 10 W and 30 W configurations consult (13). 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 13 File CMS88, MBS
*) The ANPC3 is an ANPC1 complemented with one extra TXBP and one extra MCU to support two Tx antennas. This together with an extra ATCC and one extra ANPC cable makes it possible to support 32 carriers and to reduce the channel separation to less than 360 kHz. The ANPC3 is not included in any standard configuration. 2.4.4.3 ANPC, 50 W The ANPC for 50 W houses units for the receive path, supervision of both TX and RX path, connection for TMA and alarm. For the 50 W configurations there is one ANPC1 and one ANPC2 version. The ANPC1 for the 50W configuration hosts units for one cell, and ANPC2 hosts units for two additional cells. Like in the 10 W and 30 W configurations receiver diversity is implemented, i.e. ANPC1 has two Rx antennas and ANPC2 has four Rx antennas, and each receive path has one RXBP filter. After the Rx signal has been filtered it is amplified in the Multicoupler (MCA and MCB, one for each bransch) The gain is automatically adjusted depending whether a TMA is used or not. The optional RFTL is connected to the input of the multicoupler and to the output of the MCU located in the ATCC The cabinet also houses a Power connection board (POC), a fan unit, a BIAST and a power unit (POALNA) for the TMA. For more information about the ANPCs for the 50 W configurations consult (25) and (26). 2.4.5 TMA The TMA (Tower Mounted Amplifier) is an optional amplifier mounted in each RXbranch. The unit shall be mounted on the RXantennas in the top of the antenna tower. The TMA amplifies the signal in the RXchain down to the multicoupler input. The TMA is designed for outdoor environments according to reference 4. The temperature range for normal operation is extended from 33 to +55 degrees Celsius. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 14 File CMS88, MBS 2.4.6 RFTL KIT The RFTL kit (NTM/ROA 119 3156/2) is optional and is used for testing and calibration. The kit contains an RFTL board and cabling. The RFTL has four functions: RF signal looping, output power measurement, reflected power measurement and RF signal generation. Three functions are implemented in the system with the help of RFTL: Output power calibration, RSSI measurement and TX antenna supervision. (More functionality is implemented in the next MBS release.) 2.5 SUPPORT AND INTERCONNECT PART PRODUCTS 2.5.1 POWD The Power distribution in a base station is done through the POWD (BMK 505 01/1). The distribution cabinet contains 32 (20 A) circuit breakers (current limitations see (7). Nominal input voltage level from a rectifier is 27.2 V. For more information consult (14), (15) and
(12). The Power distribution in the 50 W base station is done through the POWD (BMK 505 01/3). This distribution cabinet contains 32 (30 A) circuit breakers. 2.5.2 BASE SET The Base set (NTM 201 298) contains a base frame and a top cover. A rack of cabinets is mounted on the Base frame. The top cover is mounted on top of the top cabinet in a rack. 2.5.3 SIDE COVER KIT The side cover kit (NTM 201 674/1) is used to cover a cabinet side. Only the cabinets at the far left and far right in a configuration are covered. In all six configurations 5 cabinets are stacked in a rack. Hence 10 covers are necessary. 2.5.4 EARTHQUAKE PROOF SET The Earthquake proof set (NTM 201 680/1) is an option and is ment to be used in sites situated in earth quake risky areas. The kit stabilizes the rack and provents to some extent the bolts in the base frame to be sheered of during a quake. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 15 File CMS88, MBS 2.5.5 CABLE SETS Different standard cable sets are available to be used for the configurations of RBS 884. The main sets NTM 201 686 consists of three kits, one RF cable kit, one CLINK cable kit and one Power cable kit. If an expansion from the basic configuration is made, another RF cable kit, CLINK cable kit and Power cable kit is needed. Following table shows how the Main cable sets fit in the different configurations. Configuration 10 W Omni 10 W Two sector 10 W Three sector 30 W Omni 30 W Two sector 30 W Three sector 50 W Omni 50 W Two sector 50 W Three sector Suffix xxx 100 to 101 200 to 202 300 to 304 400 to 403 500 to 505 600 to 605 700 to 707 800 to 814 900 to 915 Table 1. Product suffix numbers (NTM 201 686/xxx). For more information about cabling consult (12). 2.6 RBS 884 MACRO USER LIBRARY The User library (LXF 102 20) is an orderable product. Three manuals are included a Site engineering manual, an Installation and maintenance manual (ref. 12) and a Parts catalog. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 16 File CMS88, MBS 3 3.1 INTERCONNECTION BASICS CLINK CLINKs are used to connect device equipment such as TRXs and CTCs to the RTT boards in the CRI. CLINKs for TCBs are grouped in 4 CLINKS per cable. In 10 W configurations 4 cables per TCB cabinet are necessary to connect all 16 positions. In 30 W configurations 2 cables per TCB are used to connect all 8 positions. CLINK cables with one CLINK per cable are used to connect ANP parts. Detailed information about how the CLINKs are connected in the different configurations are given in (16) to
(21). For more information on the CLINK interface consult ref. (22). 3.2 RECEIVE PATH The antennas are connected to the RXBPs i the ANPC. From the RXBPs the receive path is connected to the multicoupler (MCA and MCB) inputs and then from the multicoupler outputs to PSPs in TCBs. In 30 W configurations connections between PSP 8/2 and PSP 2/2 are done. In 50 W configurations connections between PSP 8/2, PSP4 and PSP 2/2 are also done. The RX path is finally connected to the TRXs through the RF backplane
(PSPB). Nominal gain through the chain is between 5 and 7 dB.
(Lower gain in TCB with PSP 2/2). The noise figure of the base station is approximately 2 dB lower than for the TRX stand alone. The intercept point is consequently also lower. Typical RF budgets for the different types of RX paths in 10 W, 30 W and 50 W configurations are given in figure 1, 2 and 3. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 17 File CMS88, MBS ANTENNA PORT RXBP MCA PSP16 PSPB 0 dB 0,7 dB 22,6 dB 21,6 dB 14,7 dB 6,7 dB 10 W CONFIGURATION (WITHOUT TMA) Fig. 1: Typical RF level budget for 10 W configuration
(without TMA). 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 18 File CMS88, MBS ANTENNA PORT RXBP MCA 0 dB 0,7 dB 22,2 dB 21,6 dB PSP 8/2 PSP 2/2 PSPB 14,7 dB 6,7 dB PSPB 14,1 dB 13,1 dB 5,1 dB 30 W AND 50 W (WITHOUT TMA) CONFIGURATION Fig. 2: Typical RF level budget for 30 W and 50 W configuration (without TMA). 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 19 File CMS88, MBS ANTENNA PORT FEEDER TMA RXBP MCA 0 dB 11 dB 7 dB 6,3 dB 23,5 dB 22,5 dB PSP 8/2 PSP 2/2 PSPB 15,6 dB 7,6 dB PSPB 50 W CONFIGURATION WITH TMA 15 dB 14 dB 6 dB Fig. 3: Typical RF level budget for 50 W configuration
(with TMA). 3.3 TRANSMIT PATH A transmit path is connected from the front of the TRX to a combiner in an ATCC. Each combined TX signal is connected to an ANPC that is connected to a TX antenna. Typical attenuation from a TRX output to the antenna output in the TX path is between 3 and 5 dB. The attenuation varies with the number of TRXs connected, the combiner type and the channel frequency separation. An RF budget is given in the figure 2 below. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 20 File CMS88, MBS TRX 40.4 dBm 44.7 dBm ATCC 36.9 dBm 41.2 dBm ANPC 36.4 dBm 40.7 dBm TRANSMIT PATH 10 W AND 30 W CONFIGURATIONS (24 CARRIERS) ATC and DCCTC TXBP and MCU TRX 47.5 dBm ATCC 43.7 dBm ATC, TXBP AND MCU TRANSMIT PATH 50 W CONFIGURATIONS (32 CARRIERS) Figure 4: Typical RF budget in RBS 884. 3.4 POWER Power is distributed from POWD. Most cabinets are connected with two cables per cabinet. An exemption is the TCB cabinet which is connected with 4 cables per cabinet. Distribution losses to cabinets are typically less than 1 V. A rectifier is not included in HRB 104 11 but is required. 3.5 EXTERNAL INTERFACES Consult (1). 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 21 File CMS88, MBS 4 CONFIGURATIONS Twelve types of configurations of the RBS 884 Macro base station has been designed. These are 10 W Omni site, 10 W two sector site, 10 W three sector site, ditto 30 W and ditto 50 W (with ATCC1/ATCC2 or ATCC3). All are shown in figure 5 and 6 on the next pages. The cabinet layouts are all maximum five cabinets high. TCBs and ATCCs are to some extent located in a onerowpercell pattern. Only POWD and CRI are located in the top row (row E) in the configurations. The TCB cabinet is split between two or three sectors in some locations in order to reduce the empty space as much as possible. A suitable PSP must be selected for each TCB as indicated in figure 5. The maximum configuration can be reached in a number of expansion steps each one including 4 carriers per cell.
(Expansions of less than 4 carriers is possible.) This is described in the configuration descriptions ref (16) to (21). (All these documents are not released yet. Please, consult 1095HRB 104 11) 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 1
L L E C 2
L L E C 22 File CMS88, MBS 3
L L E C Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked 1
L L E C 2
L L E C 3
L L E C D W O P D W O P I 1 R C b B C T 2 C P N A 1 C P N A 2 C C T A 1 C C T A a B C T b B C T b B C T 2 I R C 1 I R C b B C T 2 C P N A 1 C P N A D W O P 2 C C T A 1 C C T A a B C T b B C T 1
L L E C 2 C C T A 1 C C T A a B C T 2 C C T A 1 C C T A a B C T I 2 R C 2
L L E C 2 C C T A 1 C C T A a B C T C C T A C C T A B C T B C T D W O P I R C 1 C P N A S L L E C D E K C A T S
. I S R E R R A C 4 2
3
. W 0 1 X R T S L L E C D E K C A T S
. I S R E R R A C 4 2
2
. W 0 1 X R T L L E C N M O I
. I S R E R R A C 4 2
. W 0 1 X R T
4 W 0 3 W 0 1 n o c f 4 P S P
b B C T
, 6 1 P S P
a B C T
e t o N 4 P S P
b B C T
, 6 1 P S P
a B C T
e t o N 6 1 P S P
B C T
e t o N c B C T c B C T 2 C P N A 1 C P N A I 2 R C c B C T c B C T 1 I R C D W O P c B C T 2 C C T A 1 C C T A a B C T b B C T c B C T 2 C P N A 1 C P N A 2 I R C c B C T 2 C C T A 1 C C T A a B C T b B C T 1
L L E C 2 C C T A 1 C C T A a B C T b B C T c B C T 2 C C T A 1 C C T A a B C T b B C T 2
L L E C 2 C C T A 1 C C T A a B C T b B C T
2 2 P S P
b B C T
, 2
8 P S P 4 P S P
a B C T
c B C T
s e t o N 2
2 P S P
b B C T
, 2
8 P S P 4 P S P
a B C T
c B C T
s e t o N I 1 R C D W O P D W O P D W O P S L L E C D E K C A T S
. I S R E R R A C 4 2
3
. W 0 3 X R T S L L E C D E K C A T S
. I S R E R R A C 4 2
2
. W 0 3 X R T L L E C N M O I
. I S R E R R A C 4 2 b B C T I R C a B C T 1 C P N A C C T A C C T A b B C T a B C T 2
2 P S P
b B C T
2 8 P S P
a B C T
e t o N
. W 0 3 X R T D W O P Figure 5: Cabinet layouts for 24 carriers per cell 10 W and 30 W configurations. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 23 File CMS88, MBS b D W O P h B C T g B C T a D W O P b D W O P I b R C a D W O P d B C T D W O P b 1 C P N A b I R C a I R C a 1 C P N A e B C T c B C T I a R C I R C 1 C P N A b 3 C C T A d B C T c B C T a 3 C C T A a 2 C C T A a 1 C C T A a B C T b B C T 3 C C T A f B C T e B C T d B C T a 1 C P N A b 1 C P N A c B C T c B C T C P N A 2 C C T A 1 C C T A D W O P I R C n B C T b B C T a B C T k B C T f B C T b 2 C C T A b 1 C C T A b B C T a B C T e B C T b B C T a B C T c D W O P r B C T b D W O P c I R C n B C T a D W O P b D W O P a I R C a D W O P 2 I R C p B C T 2 C P N A o B C T a I R C 1 C P N A k B C T b I R C 2 C P N A 1 C P N A c 3 C C T A k B C T f B C T c B C T b 3 C C T A e B C T d B C T a 3 C C T A g B C T b 2 C C T A b 1 C C T A b B C T e B C T h B C T g B C T h B C T a 2 C C T A a C C T A a B C T b B C T a B C T q B C T f B C T C 2 C C T A C 1 C C T A c B C T d B C T
. 3 C C T A h t i w s r e i r r a c 2 3
3
. W 0 5 X R T
. 2 C C T A d n a 1 C C T A h t i w s r e i r r a c 0 2
3
. W 0 5 X R T
. 3 C C T A h t i w s r e i r r a c 2 3
2
. W 0 5 X R T
. 2 C C T A d n a 1 C C T A h t i w s r e i r r a c 0 2
2
. W 0 5 X R T s r e i r r a c 2 3
1
. W 0 5 X R T
. 3 C C T A h t i w
. 2 C C T A d n a 1 C C T A h t i w s r e i r r a c 0 2
1
. W 0 5 X R T Figure 6: Cabinet layouts for 50 W TRX, 32 carriers per cell 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 24 File CMS88, MBS 5 ACRONYMS AND ABBREVIATIONS AMPS ANP ANPC AVC ATCC CC CID CLINK CRI CSU CTC DAMPS DCCTC DCCH DCON DTC p /4DQPSK E1 EMC EMRP EMRPS ETB FM MBS MCA MCB MCU MSC PCB PCM PFCON POALNA POC POWD PSP PSPB RITSW RFTL RMU RTT RXBP SR STR SW T1 TCB TIM TMA TRX TXBP VER Advanced mobile phone system Antenna near part ANP complimentary equipment cabinet Analog voice channel Autotuned combiner cabinet Control channel (IS54) Cabinet (position) identity switch Control link Control and radio interface Customer service unit Combiner tuning controller Digital AMPS Direction coupler for the CTC Digital control channel CLINK connenction board (TCB) Digital traffic channel Differential quadrature phase shift keying 32 channel PCM Electromagnetic compatibility Extension module regional processor EMRP with DEVSB Exchange terminal board Frequency modulation Subsystem Mobile base station
(ANT 244 01) Multicoupler (branch A) Multicoupler (branch B) Measuring coupler unit Mobile services switching center Printed circuit board Pulse code modulation Power connection board (TCB) Power connection board, TMA Power connection board (ANPC) Power distribution Power splitter Power splitter (radio) backplane Radio interface time switch Radio frequency test loop Radio Matching Unit (dummy) Radio transceiver terminal Receive band pass filter Signal strength receiver Signaling terminal regional Software 24 channel PCM Tranceiver cabinet Timing module Tower Mounted Amplifier Transceiver Transmit bandpass filter MS verification receiver 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 25 File CMS88, MBS 6 REVISION INFORMATION A > B:
<ERAAFOL>
This revision is updated for the 50 W RBS 884 after technical review, ref. (27). Some of the major changes follow below. 2.3.1 Updated the TRX allocations in the TCBs. 2.4.2 Updated the ATCC information. 2.4.4 Updated the ANPC information and added information about ANPC3. 3.2 3.3 Updated figure 2 and 3. Updated figure 4. 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 26 File CMS88, MBS 7 REFERENCES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 8/1551ANT 244 01 Uen, DESCRIPTIONRBS 884 Base station hardware. 1551ANT 244 01 Uen, DESCRIPTIONMobile base station subsystem 29/1551ANT 244 01 Uen, DESCRIPTIONMBS software in CMS 88 11/1056ANT 244 01 Uen, REQUIREMENT SPECIFICATIONClimatic and mechanical 12/1056ANT 244 01 Uen, REQUIREMENT SPECIFICATIONSafety 1551COA 109 294 Uen, DESCRIPTIONCOP 155 18HRB 104 11 Uen, APLICATION INFORMATION 1551BFE 401 66/1, DESCRIPTIONTransceiver cabinet 1551KRC 121 10+ Uen DESCRIPTIONTRX 1551BFE 401 017/1 DESCRIPTIONATCC1 1551BFE 401 019/1 DESCRIPTIONATCC2 EN/LZB 119 2170 RBS 884 Installation and maintenance manual 1551BFE 401 022/1 DESCRIPTIONANPC1 1553BMK 505 01 Uen Directions for use 155 02HRB 104 12 Uen Product data 1/1551HRB 104 11 Uen DESCRIPTION10 W omni Configuration 2/1551HRB 104 11 Uen DESCRIPTION10 W two sector Configuration 3/1551HRB 104 11 Uen DESCRIPTION10 W three sector Configuration 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord - Prepared ERA/AR/SK ERAAFOL Dokansv/Godk - Doc respons/Approved AR/SKC (Mats Ek) Faktaansvarig - Subject responsible Kontr - Checked DESCRIPTION Nr - No 1551HRB 104 11 Uen Datum - Date 19961011 Rev B 27 File CMS88, MBS 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 4/1551HRB 104 11 Uen DESCRIPTION30 W omni Configuration 5/1551HRB 104 11 Uen DESCRIPTION30 W two sector Configuration 6/1551HRB 104 11 Uen DESCRIPTION30 W three sector Configuration 26/155 19ANT 244 01 Uen Interwork description CLINK layer 1 1551BFE 401 050/1 Uen DESCRIPTIONATCC1 1551BFE 401 052/1 Uen DESCRIPTIONATCC3 1551BFE 401 037 Uen DESCRIPTIONANPC1 1551BFE 401 038 Uen DESCRIPTIONANPC2 12/0064FCP 103 749 Uen MinOfMeet 1551BFE 401 058/1 DESCRIPTIONATCC1 1551BFE 401 059/1 DESCRIPTIONATCC2 EN/LZB 119 2786 Uae RBS 884 Integration Guidelines AS 100 1551HRB10411.WTEK Copyright Ericsson Radio Systems AB 1996 Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF 137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 1 (24) File FMIFV5R5_XCBJtvQr_ LIB - LINE INTERFACE BOARD ROF 137 8406 1 1.1 2 2.1 2.2 2.3 2.4 2.5 3 4 4.1 4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.3 4.3.1 4.3.2 4.3.3 4.3.4 4.4 4.5 4.6 4.7 5 5.1 5.2 Contents:
GENERAL Indexes FUNCTIONAL DESCRIPTION Current feed Signalling Transmission Testing Overvoltage protection REALISATION TECHNICAL DATA Current feed Signalling DC signalling Ring signalling Tone signalling Signalling between EMRP and LIB Transmission Levels Impedances Noise Spurious effects Power supply Clock signals Mechanical data Power dissipation ENVIRONMENTAL PERFORMANCE Climatic Overvoltages Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 2 (24) File FMIFV5R5_XCBJtvQr_ 1 1.1 GENERAL The Line Interface Board, LIB, interfaces between 8 analogue subscriber lines and a digital switching network. The LIB is a part of the AXE subsystem SSS
(Subscriber Switching Subsystem) LIB implements the following functions for 8 subscribers:
- Current feed of the subscriber line (2x300 ohms and 2x400 ohms).
- Off- and onhook detection.
- Polarity reversal of current feed.
- Ring signal sending.
- Ring trip.
- Subscriber line and line circuit test possibility.
- Overvoltage protection.
- 2/4 wire conversion.
- A/D and D/A conversion including filtering.
- Common control bus interface.
- Common speech bus interface. Indexes The index of a board defines the relative sending and receiving levels, the current feeding resistance and the input impedance. Table 1 shows the relation between index, levels, current feeding and input impedance. Table 1: Index of LIB8 Variant Transmit level (dBr) Receive level (dBr) Current feed. resistance Input impedance ROF 137 8406/1 ROF 137 8406/2 ROF 137 8406/3 ROF 137 8406/11 ROF 137 8406/12 ROF 137 8406/13 ROF 137 8406/21 0 0 0 0 0 0 0
-7.0
-6.0
-4.0
-7.0
-6.0
-4.0
-7.0 2 x 400 ohms 600 ohms 2 x 400 ohms 600 ohms 2 x 400 ohms 600 ohms 2 x 300 ohms 600 ohms 2 x 300 ohms 600 ohms 2 x 300 ohms 600 ohms 2 x 300 ohms 900 ohms Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 3 (24) File FMIFV5R5_XCBJtvQr_ 2 2.1 FUNCTIONAL DESCRIPTION Current feed At nominal battery voltage i.e. -48 V, the LIB8 could be used for lines with loop resistance up to about 1800 ohms if decadic impulsing (60/40 ms), is used.
( A cable of 0.4 mm diameter, twisted pair, has a nominal loop resistance of 278 ohms/km ) If tone signalling ( DTMF) is used, the line lenght could be somewhat extended. As a rule, the loop resistance should not exceed 2500 ohms. The maximum loop resistance could however be limited for other reasons, e.g. by the type of telephone set used or particular requirements on the line current specified by the local administration. 2.2 Signalling The LIB performs the following signalling functions:
DC-signalling:
- Loop detection
- Reception of digits with decadic impulsing
- Polarity reversal Ring signalling:
- Ring signal superimposed on battery, -48V
- Ringtrip detection Tone signalling:
- Transmission and reception of DTMF-signals. 2.3 Transmission Relative level:
The relative levels in transmit and receive direction are defined by the index of a board. Table 1 shows the relation between index and levels. Input impedance:
The input impedance is for index .../1,2,3,11,12,13 600 ohms resistive. For index .../21 the input impedance is 900 ohms resisrive. Balance impedance:
The balance impedance is a complex three element circuit. The impedance is shown in figure 4. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 4 (24) File FMIFV5R5_XCBJtvQr_ 2.4 Testing With a test relay, the line circuit and the subscriber line can be connected to central testing equipment through a test bus. 2.5 Overvoltage protection The LIBs are protected by means of PTC-resistors (Positive Temperature-
Coefficient), VDRs (Voltage Dependent Resistor) and zener-diodes. The zener-diodes protect the low voltage part of the circuit against transients, mainly caused by lightning. The VDR lowers the strain on the transformer and the components behind the transformer, in case of transversal (metallic) overvoltages, especially of transient nature. The PTCs act as resettable fuses that increase their resistance strongly when heated up by an overcurrent. The power dissipation on the board is thereby limited to a safe level. When the overcurrent has disappeared, the PTC will cool down and return to its normal low-ohmic state. Thus no manual intervention is necessary to res-
tore the line, as would be the case in a fuse-protected system. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 5 (24) File FMIFV5R5_XCBJtvQr_ 3 REALISATION A block diagram of the LIB is shown in figure 1. Test OVP SUBSCR. LINE Hybrid and current feed Ring and Pol.inv relay DP Combo DEV-
BIC TEST BUS DEVICE CONTROL BUS DEVICE SPEECH BUS Figure 1. Block diagram (only one of two DP and DEVBIC are shown) Description of the different blocks in fig 1:
OVP:
Overvoltage protection network is shown in fig 2 Feeding resistors Hybrid To combo Varistor Battery PTC a-wire b-wire PTC Zenerdiodes Figure 2. Overvoltage protection Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 6 (24) File FMIFV5R5_XCBJtvQr_ RELAYS:
- Test relay for connection to test bus.
- Ring relay for connection to ring generator.
- Polarity inversion of battery. HYBRID AND CURRENT FEEDING:
The 2/4 - wire hybrid consists of an E-type iron core transformer. A simplified circuit diagram of the hybrid is shown in figure 3. The balance network (transformed to the line-side of the transformer) is shown in figure 4. Resistors are used to feed the subscriber line through the hybrid transformer. Transformer a-wire
-RG
-48V b-wire Ring relay Current feed resistors Hook status Pole
. inv relay Figure 3. Transformer SLIC, simplified diagram. Balance imp. Transmit(-) Transmit(+) Combo Receive 330 536 100 nF Figur 4. Balance network (standardized values at the transformers line-side) Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 7 (24) File FMIFV5R5_XCBJtvQr_ COMBO:
The combo performs the A/D and D/A conversion and filtering for the speech signal. It also codes the speech signal to A-law, PCM-code. The input and output relative levels are set by gain setting resistors at the ana-
log input and output of the combo. DEVBIC:
The Device Bus Interface Circuit links the low speed PCM speech bus
(2Mb/s) on the board to the high speed speech bus, DEVSB (12Mb/s), in the magazine. The board is equipped with two DEVBIC circuits, each connecting four lines to the DEVSB. DP:
The board is equipped with two Device Processors. Each processor controls and supervises four lines on the board and communicates with master software via the Device Control Bus DEVCB. The subscriber hook states, including dial pulses, are detected by the DP through precision resistor networks and comparators. The hook states during ringing are detected the same way by software integration and filtering of the comparator outputs. Ring tripping is done autonomously. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 8 (24) File FMIFV5R5_XCBJtvQr_ 4 4.1 4.2 TECHNICAL DATA Current feed The current feed of LIB8 is 2x400 ohms (indexes 1-3) or 2x300 ohms
(indexes 11-13 and 21) resistive as shown in figure 3. The characteristic is linear, but if the current exceeds 100 mA e.g. due to a short circuit close to the MDF, the PTC resistors start to limit the current. This will keep the heat generation on a safe level. Signalling Subscriber loop signalling is performed according to:
1/1914 - ANS 13101 2/1914 - ANS 13101 1/1914 - ANS 13301 2/1914 - ANS 13301 4.2.1 DC signalling Loop detection:
The threshold for detecting a transition on hook -> off hook, is a loop resis-
tance < 4200 ohms, and a transition off hook -> on hook, a loop resistance
> 4200 ohms for indexes 1-3. For indexes 11-13 and 21 the threshold is 4000 ohms. The line current for which the transition occurs is about 10 mA for all indexes. However, if the loop resistance should be close to the thresholds,, the detector would be sensetive to disturbances on the line and therefore the maximum loop resistance should not exceed 2500 ohms. The loop detector output is filtered in the device processor before the changes are reported to the EMRP (Extension Module Regional Processor). The filter time is programmable. Default is 5 ms. Decadic impulsing:
No digit analysis is done by the device processor during decadic impulsing. Only changes in hookstate, filtered as described above, are reported to EMRP. The performance for decadic impulsing depends upon the subscriber equipment, the characteristic of the subscriber line and the filtering time. As a rule, the decadic impulsing could be used in subscriber loops with a loop resistance < 1800 ohms. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 9 (24) File FMIFV5R5_XCBJtvQr_ 4.2.2 Polarity reversal:
Polarity reversal of the current feed is done by means of a relay, controlled by the device processor. Ring signalling The ring signal is received from a central ring generator which, via the ring relay and feeding resistors, feeds the subscriber line with ring signal superim-
posed on the battery voltage -48V. The ring voltage and frequency are determined by the ring generator, com-
monly 70V - 105V rms, 25 Hz. The ring cadence is determined by the central software. The hook status during ringing is supervised by the loop detector of which the output is oscillating at the frequency of the ring voltage. The time ratio, output high/output low, is dependent of the hook status and by time measurements in the device processor an hook off will be detected. The ring trip is performed autonomously when the conditions are fulfilled. To avoid false ring trip, the detector output is filtered i.e. after a change, it must be stable for a certain time, before the change is recognized. The filtering time as well as the time ratio are programmable i.e. set by central software. Default values are:
Ringtrip time high 20.5 ms Ringtrip time low 20.0 ms Testpoint filtering time 5.0 ms See 4.2.4 Signalling between EMRP and LIB for more details. Tone signalling 4.2.3 DTMF signalling:
The LIB board does not generate or detect DTMF signals. The tones are sent through the normal transmission path. Generation and detection of DTMF must be done in central equipment. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 10 (24) File FMIFV5R5_XCBJtvQr_ 4.2.4 Signalling between EMRP and LIB EMRP -> DP:
SIGNAL NO. DEC HEX 0 1 1 2 3 4 00 01 01 02 03 04 5 6 7 8 9 10 11 12 13
05 06 07 08 09 0A 0B 0C 0D
NAME DATA DEVPIDREQUACK ECHO ECHO1 SUBCON SUBDECON UPDATE IDLELI RINGON RINGOFF POLINVON POLINVOFF TESTACCON TESTACCOFF COMBOON COMBOOFF GO AHEAD id,05,00,0i,cs id,05,01,0i,cs id,06,01,0i,d5,cs id,05,02,0i,cs id,05,03,0i,cs id,0D,04,0i,d1,d2,d3,d4,d6, d7,d8,d9,cs id,08,05,0i,d2,d4,d6,cs id,05,06,0i,cs id,05,07,0i,cs id,05,08,0i,cs id,05,09,0i,cs id,05,0A,0i,cs id,05,0B,0i,cs id,05,0C,0i,cs id,05,0D,0i,cs 80+id id = DP no. 0i = ind no. cs = checksum 00 = released d1 = ring relay 00 = released d2 = polinv. relay 00 = released d3 = test relay d4 = test point (tp) 00 = on hook d5 = order code (tp value) 00 = send off d6 = combo status d7 = ringtrip time high d8 = ringtrip time low d9 = tp filtering time 00 = power off in 0.5 ms step in 0.5 ms step in 0.5 ms step 00 - 7F 00 - 03 01 = operated 01 = operated 01 = operated 01 = off hook 01 = send on 01 = power on Description of DATA (Byte 1-4) :
Byte 1 = (id) Device processor number Byte 2 = Number of bytes in message Byte 3 = Signal number Byte 4 = Individual (circuit) number Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 11 (24) File FMIFV5R5_XCBJtvQr_ DP -> EMRP:
SIGNAL NO. DEC HEX 1 2 3 41 65 01 02 03 29 41 NAME DATA ECHOR ONHOOK OFFHOOK ECHOR1 DEVPIDREQ id,07,01,0i,d1,d2,cs id,06,02,0i,d3,cs id,06,03,0i,d3,cs id,09,29,0i,d1,d2,d4,d5,cs FF,05,41,00,46 00 - 7F 00 - 03 id = DP no. 0i = ind no. cs = checksum d1 = no. of checksum faults d2 = no. of identity faults d3 = time for change d4 = type of line card d5 = value of testpoint according to:
LIB-5, LIB-7 and LIB8= 00 MSB LSB 0 0 0 0 b3 b2 b1 b0 d5 bi = 0 Channel no. (i) in state HOOK ON bi = 1 Channel no. (i) in state HOOK OFF Description of DATA (Byte 1-4) :
Byte 1 = (id) Device processor number Byte 2 = Number of bytes in message Byte 3 = Signal number Byte 4 = Individual (circuit) number 4.3 Transmission This section describes the typical transmission performance for signals pas-
sing through the analogue 2 wire interface and the digital 4 wire interface of the LIB board. This is defined as the Z-interface in the ITU-T Rec Q.551. The performance is described by measurements on half-channels, using the terms input and output connection, as defined in ITU-T Rec Q.551. The performance for connections through an exchange involving two analo-
gue interfaces can be determined by suitably combining the values for the va-
rious parameters. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 12 (24) File FMIFV5R5_XCBJtvQr_ 4.3.1 4.3.1.1 4.3.1.2 4.3.1.3 Levels The nominal input and output relative level of the LIB8 is defined by its index. Table 1 shows the relation between index and relative levels. Tolerances of relative levels The difference between the actual relative level and the nominal assigned re-
lative level, which arises from design tolerances, adjustment increments, cabling etc. should lie within the following limits:
Input connection -0.3 to +0.7 dB Output connection -0.7 to +0.3 dB Short-term variation of loss with time When a sine-wave signal at a reference frequency of 1020, +2 Hz -7 Hz and at a level of -10 dBm0 is applied to the 2-wire analogue interface of any input connection, or a digitally simulated sine-wave signal of the same characteris-
tic is applied to the exchange test point Ti of any output connection, the level at the corresponding exchange test point To and the 2-wire analogue interface respectively should not vary by more than +/- 0.2 dB during any 10-minute in-
terval of typical operation under the permitted variations in the power supply voltage and temperature. Receive cut off In order to reduce the risk of instability during those periods when the line circuit is not effectively terminated by the subscriber, the 4-wire loop is set to 6 dB attenuation in the output connection of the line interface during that same period. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 13 (24) File FMIFV5R5_XCBJtvQr_ 4.3.1.4 Variation of gain with input level With a sine-wave signal at a frequency of 1014 H z applied to the port of any channel at a level between -55 to +3 dBmO, the gain variation of that channel relative to the gain at an input level of -10 dBmO, lies within the limits shown in Figure 5. Input as well as output connection.
[dB]
Gain variation 1.6 0.6 0.3 0
- 0.3
- 0.6
- 1.6
-55 -50
-40
-10
+3
[dBm0]
Input Level Figure 5. Variation of gain with input level. 4.3.1.5 Loss distortion with frequency The loss distortion is expressed in terms of the loss at a specified frequency, relative to the loss at 1014 Hz, for the nominal frequency band 200 Hz to 3400 Hz. At a nominal input level of -10 dBmO the distortion lies within the limits shown in Figure 6 for input connection and Figure 7 for output connection. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 14 (24) File FMIFV5R5_XCBJtvQr_
[dB]
1.5 1.0 0.75 0.5 0.3 0
-0.3
[dB]
1.5 1.0 0.75 0.5 0.3 0
-0.3 Loss INPUT CONNECTION Frequency 0.2 0.3 0.4 0.6 1.02 2.4 3.0 3.4 3.6 [kHz]
Figure 6. Loss distortion with frequency, input connection Loss OUTPUT CONNECTION 0.2 0.3 0.4 0.6 1.02 2.4 3.0 3.4 3.6 [kHz]
Frequency Figure 7. Loss distortion with frequency, output connection Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 15 (24) File FMIFV5R5_XCBJtvQr_ 4.3.1.6 Group delay The values given in this part do not include any delays due to frame aligners and time stages in the switching matrix, which will be present in a complete connection. Absolute group delay:
The absolute group delay is defined as the group delay measured at the frequency where it has its minimum value in the band 500 to 2500 Hz. This value is below 700 us for a connection set up through one pair of line circuits. Group delay distortion:
The group delay distortion is measured relative to the absolute group delay in the frequency band 500 to 2800 Hz. The distortion lies within the limits shown in Figure 8. The mask is valid for both input and output connection. Group Delay Distortion
[us]
900 750 450 150 0 0.5 0.6 1 2.6 2.8 Figure 8. Group delay distortion with frequency Frequency
[kHz]
Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 16 (24) File FMIFV5R5_XCBJtvQr_ 4.3.2 4.3.2.1 Impedances Input impedance The nominal input impedance is 600 ohms for index .../1,2,3,11,12,13 and 900 ohms for index .../21. Return loss for index 1,2,3,11,12 and 13 measured against a 600 ohms resistor is:
> 16 dB in the frequency band 300 to 600 Hz
> 20 dB in the frequency band 600 to 3400 Hz For index 21, the return loss measured against a 900 ohms resistor is:
> 14 dB in the frequency band 300 to 500 Hz
> 18 dB in the frequency band 300 to 600 Hz
> 14 dB in the frequency band 2000 to 3400 Hz 4.3.2.2 Impedance unbalance about earth The longitudinal conversion loss (LCL), defined in ITU-T Rec G.117, 4.1.3, exceeds the following minimum values, with the equipment under test in normal talking state:
Index 1,2,3,11,12,13:
> 46 dB in the frequency band 300 to 600 Hz
> 52 dB in the frequency band 600 to 3400 Hz Index 21:
> 40 dB in the frequency band 300 to 600 Hz
> 46 dB in the frequency band 600 to 3400 Hz Test method:
Longitudinal conversion loss should be measured in accordance with the prin-
ciples given in Recommendation 0.121, paragraph 2.1 and 3. figure 9 shows an example of the basic measuring arrangement for digital exchanges. Measurements of the longitudinal and transversal voltages should preferably be done with frequency-selective level meter. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 17 (24) File FMIFV5R5_XCBJtvQr_ C2 interface Z VT1 Item under test Pi BN Po To Exchange test points Ti Quiet code Sinusoidal generator R/4 R VL1 BN: Balance network R should be in the range of 600 - 900 ohms Longitudinal conversion loss (LCL) = 20 log10 dB VL1 VT1 GND Figure 9. Arrangement for measuring LCL 4.3.2.3 Terminal balance return loss (TBRL) The TBRL is related to the loss aio between the exchange test points Ti and To
(see Figure 10) of a half connection as follows:
TBRL
aio f(
ao ai+
) where ao and ai are the the losses 2-wire port to Ti and To to 2-wire port , measured at 1020 Hz. The balance network is shown in Figure 5. Using an sinusoidal test signals the measured TBRL exceeds the limits shown in Figure 10 towards the actual balance test network. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 18 (24) File FMIFV5R5_XCBJtvQr_ Return loss
[dB]
20 16 0 0.3 0.5 2.5 3.4 [kHz]
Frequency 4.3.3 4.3.3.1 4.3.3.2 4.3.3.3 4.3.3.4 Figure 10. Limits for TBRL Noise Weighted noise With a maximum noise level on the battery voltage of 2 mVp
(psophometric weighted), in the frequency range 25Hz - 5kHz, the weighted noise ( idle channel noise ) is less than :
-64 dBm0p input connection
-67 dBm0p output connection measured with an instrument in accordance with ITU-T Rec. O.41. Unweighted noise The level of total unweighted noise power, measured with an O.41 instrument in a 30 Hz to 3 kHz band, flat weighting, is less than -55 dBm0. Single frequency noise The level of any single frequency, e.g. the sampling frequency and its multip-
les, measured selectively is less than -50 dBm0. Impulsive noise With the input terminated in its nominal input impedance at the far end of a subscriber cable, the impulsive noise is less than 5 counts in 5 minutes at a th-
reshold level of -35dBm0 as specified in ITU-T Rec. Q.45 . These limits apply to the send path and the receive path separately. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 19 (24) File FMIFV5R5_XCBJtvQr_ 4.3.3.5 The impulsive noise counter is described in ITU-T Rec. 0.71 . Crosstalk For crosstalk measurement the following auxiliary signals are injected:
The quiet code into the decode input The activation signal into the analogue side of the channel under test. Input crosstalk:
A sine-wave test signal at the reference frequency of 1020 Hz and at a level of 0 dBm0, applied to an analogue 2-wire interface, should not produce a level in any other half connection exceeding -73 dBm0 for near-end crosstalk
(NEXT) and -70 dBm0 for far-end crosstalk (FEXT). Typical measured value -84 dBm0. The measurement shall be carried out in accordance with ITU-T Rec. Q.552, figure 8/Q.552. Output crosstalk:
A digitally simulated sine-wave test signal at the reference frequency of 1020 Hz, +2Hz -7Hz applied at a level of 0 dBm0 to an exchange test point Ti, should not produce a level in any other half connection exceeding
-70 dBm0 for near-end crosstalk (NEXT) and -73 dBm0 for far -end crosstalk
(FEXT). Typical measured value -84 dBm0 The measurement shall be carried out in accordance with ITU-T Rec. Q.552, figure 9/Q.552 4.3.4 Spurious effects at OUTPUT in presence of input signal 4.3.4.1 Total distortion including quantizing distortion With a sine-wave test signal at the reference frequency of 1020 Hz (see ITU-T Recommendation 0.132) applied to the 2-wire interface of an input connection, or with a digitally simulated sine-wave signal of the same charac-
teristic applied to the exchange test point of an output connection, the signal-
to-total distortion ratio, measured at the corresponding outputs of the half con-
nection with a proper noise weighting (see Table 4 of G.223 ) should lie above the limits shown in figure 11 and figure 12 Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 20 (24) File FMIFV5R5_XCBJtvQr_
[dB]
35.0 32.9 24.9 19.9 0 Input Connection
-45
-40
-30
- 20
-10 0
[dBm0]
Input Level Figure 11. Limits for signal to total distortion ratio as a function of input level. Sine wave method. Input relative level, Li = 0 dBr Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 21 (24) File FMIFV5R5_XCBJtvQr_
[dB]
35.0 33.8 28.8 19.5 14.5 0 Output Connection
-45
-40
-30
- 20
-10 0
[dBm0]
Figure 12. Limits for signal to total distortion ratio as a function of input level. Sine wave method. Output relative level, Lo = -7 dBr Input Level 4.3.4.2 4.3.4.3 4.4 Rejection of spurious signals With a digitally generated sine wave in the frequency range 300 - 3400 Hz, and at a level of 0 dBm0, applied to the exchange test point Ti of a half connection, the level of spurious out-of-band image signals measured selectively at the 2-wire interface, is less than -25 dBm0. Rejection of out-of-band signals With a sine-wave signal in the range from 4.6 kHz to 72 kHz applied to the 2-wire interface of an input connection at a level of -25 dBm0, the level of any image frequency produced in the time slot corresponding to the input connection will be at least 25 dB below the level of the test signal. Power supply The LIB8 must be supplied with -48V, +5V, -5V and +12V. Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 22 (24) File FMIFV5R5_XCBJtvQr_ 4.5 4.6 4.7 Clock signals The LIB8 must be supplied with 4.000 MHz and 12.288 MHz clock signals. Mechanical data Size of PCB Mounting height Weight 178 mm x 221 mm max 13.5 mm 0.5 kg Power consumption The total power consumption is the sum of the power dissipation on the board and the power fed to the subscriber line. The power consumption varies between the different generations and also between the revision states within each generation. It is also heavily depen-
dent on the length of the subscriber line and the traffic intensity. For that reason, the power consumption is specified for a board without traffic i.e. HOOK ON and the combos in POWER OFF, and for a board with traffic on all channels with a loop resistance of 600 ohms each channel. The dissipation for each supply voltage and total dissipation per board is specified in the tables below. Without traffic:
Board Power consumption (W)
+12V +5V
-5V
-48V Total ROF 137 8406/all indexes 0.02 0.53 0.03 0.66 1.2 W With traffic on all eight channels (600 ohms loop resistance):
ROF 137 8406/1,2,3 0.02 ROF 137 8406/11,12,13,21 0.02 0.8 0.8 0.2 0.2 14.2 16.6 15.2 W 17.6 W The traffic dependent power consumption per channel can be calculated according to the equations below:
Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 23 (24) File FMIFV5R5_XCBJtvQr_ Ptraffic =
where 2 U battery Rfeed + Rline
Pchannel
(Watt/channel) Rfeed = feeding resistance according to table1, page 2 Rline
= the subscriber line loop resistance
= traffic dependent power per channel drawn from the Pchannel
+12V, +5V and -5V supply voltages 0.1 W and is about U battery
= station battery voltage Example:
Calculate the total power dissipation on a board with traffic on two channels, battery voltage -48V, loop resistance 600 ohms. The feeding resistance is 2x400 ohms i.e. index 1, 2 or 3 (see table 1) The power dissipation without traffic is 1.2 W as shown above. Ptraffic =
48 2 800 + 600
+ 0.1
= 1.7 Watt / channel Ptotal
= 2 x Ptraffic
+ 1.2
= 4.6 Watt and the part dissipated in the lines:
Pline
= 2 x Ubattery
800 + Rline 2
) x Rline
= 1.4 Watt and hence the power dissipated on the board:
Pboard = Ptotal - Pline = 4.4 - 1.4
= 3.2 Watt Uppgjord -Prepared ETX/PN/XLMD ETXFBO ETX/PN/XLMD ETXFBO 1551-ROF137 8406 Uen Dokansv/Godk - Doc respons/Approved ETX/PN/XLMD Datum - Date 1999-09-07 Faktaansvarig -Subject responsible Kontr -Checked E Rev DESCRIPTION Nr - No. 24 (24) File FMIFV5R5_XCBJtvQr_ 5 5.1 5.2 ENVIRONMENTAL PERFORMANCE Climatic The board is designed to work in environment class S8 (indoor premises with regulated temperature), as defined in ST 1025-201 (Standard Technical Instruction). Overvoltage The LIB8 is basically designed to comply with the ITU-T Rec. K20. In some respects, the LIB8 exceeds the K20. For instance, the board will withstand an overvoltage of 240V rms, between the a-wire and b-wire, and between a + b-wire and ground, for at least 24 hours, without any permanent damage. The tests according to ITU-T K20, table 2/K.20 (exposed environments) have been performed with gas discharge tube as primary protection as specified in ITU-T, K12.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2000-01-18 | 869 ~ 894 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2000-01-18
|
||||
1 | Applicant's complete, legal business name |
Ericsson Radio Systems AB
|
||||
1 | FCC Registration Number (FRN) |
0005940275
|
||||
1 | Physical Address |
Torshamnsgatan 21-23
|
||||
1 |
S-164 80 Stockholm, N/A
|
|||||
1 |
Sweden
|
|||||
app s | TCB Information | |||||
n/a | ||||||
app s | FCC ID | |||||
1 | Grantee Code |
B5K
|
||||
1 | Equipment Product Code |
KRC12110-11
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
B**** B****
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
+468 ********
|
||||
1 | Fax Number |
+468 ********
|
||||
app s | Technical Contact | |||||
1 | Firm Name |
Ericsson Radio Systems AB
|
||||
1 | Name |
L**** B******** L********
|
||||
1 | Physical Address |
Torshamnsgatan 21-23
|
||||
1 |
S-164 80 Stockholm
|
|||||
1 |
Sweden
|
|||||
1 | Telephone Number |
+468 ******** Extension:
|
||||
1 | Fax Number |
+468 ********
|
||||
1 |
l******@era.ericsson.se
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Ericsson Inc
|
||||
1 | Name |
L**** L****** R****
|
||||
1 | Physical Address |
Mountain View Road
|
||||
1 |
Lynchburg, Virginia 24502
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
804 5******** Extension:
|
||||
1 | Fax Number |
804 5********
|
||||
1 |
e******@am1.ericsson.se
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Cellular AMPS/DAMPS Base Station | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
n/a | ||||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 22H | BC | 869 | 894 | 2 | 1.5 ppm | 40K0F1D | |||||||||||||||||||||||||||||||||
1 | 2 | 22H | BC | 869 | 894 | 2 | 1.5 ppm | 40K0F8W | |||||||||||||||||||||||||||||||||
1 | 3 | 22.901(d) | BC | 869 | 894 | 2 | 0.25 ppm | 30K0DXW | |||||||||||||||||||||||||||||||||
1 | 4 | 22.901(d) | BC | 869 | 894 | 2 | 0.25 ppm | 20K0FXW |