NVC ETI LIGHTING CO., LTD. Product Instruction Manual Product Name: LED ceiling lamp LED Model No. 54074491 Content 1.ProductIntroduction2 1.1ProductDescription2 1.2SchematicDiagram2 2.ProductFeature2 2.1Productcharacteristic2 2.2Specification3 2.3LightDistribution4 3. Methodofapplication47 4.MaintenanceInstruction7 5.Environmentalrequirement8 6.Productcarriedstandard8 7.Packageinstruction8 7.1Packagespecification8 7.2Packagelist8 1.Product Introduction 1.1. Product Description 1 2 292x75mmDimension: 292x75mm
:+PMMA Lampplate:SPCCPowderspray,lampcover:PMMAopticaldiffuser
builtindrive&firepreventiondrivebox 2835 SamsungLED2835 3 4 1.2. Product schematic diagram:
2. Product Featuers:
2.1. Product characteristics a. 5 7 Long lifetime (above 50,000hrs), 7 times of lifetime of b. 14W LED 60W 60High efficiency, energy fluorescent lamp:
saving, environmental friendly (A 14W led lamp can replace a 60 w electric incandescent lamp , saving 60% of energy ) c. ,,,,, Impact resistant, shock resistant, no UV and IR radiation: high conversion rate and adaptable to severe environment , universal application to office ,hotel ,supermarket ,school and library ,etc d.Green Initiative, no harmful gas is emitted, low heat is e.Authentic and pure light color, no flicker, generated while used, safe and reliable . protecting your eyes while providing better visual enjoyment . 2.2 Specification
/Item/
Electronicratings
/WRatedPower/W
/VRatedInputvoltage/V Parameter 14.5W AC120V
/HzFrequency/Hz
/%RatedPowerefficiency PFRatedPowerFactor
/ARatedInputcurrent/A RatedITHD R9RatedR9 Photometricratings LED/LEDtype/Qty. 60Hz 88%
0.9 AC120V:0.12
<20%
SMD2835/20PCS
/LmRatedLumenOutput 1000lm 4000K 80 110
(1.5)/LuxIlluminance(1.5m)/Lux
/KCCT
/RaCRI BeamAngle Physicalinformation Material operatingtemperature storagetemperature IPrating
(LWH)/mmLuminairedimension(LWH)/mm 292x75
/gNetweight
/hrsLifetime/hrs 50000h SPCC+PMMA 2045 2060 IP20 2.3 Light distribution Light distribution pattern Illuminance distribution 3 Installation Instructions 1. Put the Fixture flat on the desktop, turn the lamp shade counterclockwise , and then take out the lamp shade 2. 3. #8-32 Install the electrical box screws#8-32UNC in the junction box. 4. L N Connect the black color L line(Mark 1) to the L line come out from junction box with the wirecap. Connect the white color N line(Mark 2) to the N line come out from junction box with the wirecap. Connect green color ground line(Mark 3) to the ground line come out from junction box with the wirecap. 5. Put the central holes of the fixture plate across the screw of the junction box. 6. Rotate fixture plateperthe direction of arrow and lock it tightly with the screw lock 7. BDCBA B Lift the diffuser (B) with two hands.Aim the lock position of diffuser (D) at the one of housing plate (C).Tightly get the diffuser (B) seated in the housing plate (A).Turn the diffuser (B) clockwise to secure entirely with housing plate. 7.. 4. Maintenance instruction 4.1 Do Not use volatile solvent such as alcohol to clean the troffer. 4.2 Use soft cotton cloth with suds to clean the troffer . 4.3 Non-profecssional Do not attempt to take apart and repair the troffer . 4.4 Please use the constant-current driver exclusively adaptive to the troffer, do not change the driver without permission . FCC STATEMENT This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement, the device can be used in portable exposure condition without restriction. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. IC STATEMENT This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. 5Environment requirement Operating temperature -2045Storage temperature -2060 6Product carried standard UL-1598/UL8750/ ENERGY STAR 7 Package Instruction 7.1Packing Specification 7.2Package list Package size
Lamp Qty./box Net weight Gross weight mm
Item Qty. Ceiling lamp Instruction manual screw Wiring cap 1 1 2 3