Lighting Control Switch Version: A0 User Manual Product Name: Lighting Control Switch Model No.:
MC054V- RC- 2A MC054V- RC- 2B MC054V- RC- 2C MC054V- RC- 2D Issue Date:
March 14, 2019 Page 1 of 11 Lighting Control Switch Version: A0 eatures1. Features Operating voltage 120~277V AC, suitable to Euro & North American market. Patented microwave antenna, mounting height is 15m Max, suitable to install in most of warehouses. Supports high-sensitivity and low-sensitivity modes (for metal ceilings, metal reflector mounting environments) Work with 1-10V dimmable LED driver, easy to achieve 2-step or 3-step dimming function. New patented remote control to adjust the transmitting angle to avoid misuse. 5 years warranty 2.Parameter Operating Voltage Rage 108-305V AC, 50Hz/60Hz DC Input Voltage N/A Rated Voltage 120/277Vac,60Hz Input No-load Power Stand-by Power Surge Test Working Mode Type of Load Load Capacity N/A
<1W L--N: 1kV ON/OFF function, 1-10V step dimming Inductive or resistive Load 120VAC: 4A; 277VAC: 3A Output Current of Load N/A Max. Surge Capacity 1-10V Dimming 10%(1.4-1.6V), 20%(1.9-2.1V), 30%(2.9-3.1V), 50% (4.9-5.1V) Dim Interface Synchronous Control High Low-level PWM Control N/A N/A N/A Sensor Operating Frequency 5.8 GHz 75 MHz, ISM Band. Parameters Transmitting power 0.5mW Max. Page 2 of 11 50A (50% Ipeak, twidth =500uS, 230Vac full load, cold start);
80A (50% Ipeak, twidth =200uS, 230Vac, full load, cold start)
< 50mA Non-constant source Lighting Control Switch Version: A0 Hold time 5s/30s/1min/3min/5min/10min/20min/30min Stand-by DIM Level 10%/20%/30%/50%
Stand-by Period 0s/10s/1min/3min/5min/10min/30min/+
Detection Area 25%/50%/75%/100%
5lux/15lux/30lux/50lux/100lux/150lux/Disable (Ambient light diffusion) Detecting Radius See note 2 Mounting Height 15m Max Detecting Angle 150(wall mounting), 360(ceiling mounting) Wireless Module Operating Frequency Transmitting power Transmitting distance Modulation mode Number of coding N/A N/A N/A N/A N/A Operating Temperature
-35 +55 Operating Environment Storage Temperature Temperature:-40+80;Humidity:10%-95%
(non-condensing) IEC60669-2-1, IEC60669-1 Safety standards AS/NZS 60669.1, AS/NZS 60669.2.1 UL60730-1 EN55015, EN61000-3-2, EN61000-3-3, EN61547 Certificate Standards EMC standards AS/NZS CISPR 15, AS/NZS 4268 FCC Part 15C, Part 15B EN 60950-1, EN301489-1, EN 201489-3, EN300440 Environmental Requirem Compliant to RoHS ent Certificate Wiring Wiring color Installation Dimension Package Net Weight cULus, CE, SAA, FCC, RED SJTW,5*18AWG (USA); H05RR-F,5*18AWG (Europe,Australi a) exposed line length: 810-830mm Sheath: Black Core: Red,White,Black,Gray,Purple (US);
blue, brown, red, purple,Gray (Europe, Australia) IP Rating Protection Class IP65 Class II Others Instruction+ White box+ White box tags+ Clapboard+
MC054V RC A: 225g, MC054V RC B:246g, MC054V RC C:225g , MC054V RC D:165g Lifetime 5 years warranty @Ta 230V full load Independent
(xH)72*59mm Carton(K=A) Page 3 of 11 Lighting Control Switch Version: A0 Note 1. N/Ameans not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s. 1. Func tion1) On/OFF Function (stand-by period be set to 0s) 2) 2-step dimming function (stand-by period be set to +) 3) 3-step dimming function (stand-by period be set to 10s/1min/3min/5min/10min/30min) Page 4 of 11 Lighting Control Switch Version: A0 4.Dimension (mm) 1MC054V- RC- 2 AMC054V- RC- 2B, MC054V-RC- 2C Page 5 of 11 Lighting Control Switch Version: A0 2) MC054V- RC- 2D 5.Wiring Europe,Australia version USA version
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor. Page 6 of 11 Lighting Control Switch Version: A0 6.Function Diagram 7.Radiation Pattern Ceiling mounting Ceiling mounted height: 3m Sensitivity:
Ceiling mounted Ceiling mounted Ceiling mounted Ceiling mounted height: 6m Sensitivity:
height: 9m Sensitivity:
height: 12m Sensitivity:
height: 15m Sensitivity:
100%/75%
100%/75%/50%/25%
100%/75%/50%/25%
100%/75%/50%/25%
100%/75%/50%
Normal moving Normal moving Normal moving Normal moving Normal moving
(Speed:1m/s)
(Speed:1m/s)
(Speed:1m/s)
(Speed:1m/s)
(Speed:1m/s) Page 7 of 11 Lighting Control Switch Version: A0 Slow moving Slow moving Slow moving Slow moving Slow moving
(Speed 0.3m/s)
(Speed: 0.3m/s)
(Speed: 0.3m/s)
(Speed: 0.3m/s)
(Speed: 0.3m/s)
*Only 100%/75%/50% detection sensitivity is workable when installed at 10m & 15m mounting height. 25% sensitivity is not able to detect motion signal. Wall mounting Horizon mounted height: 2m Sensitivity: 100%/75%/50%/25%
Normal moving (Speed1m/s) Slow moving (Speed 0.3m/s) Page 8 of 11 Lighting Control Switch Version: A0 8.Remote Control 9. Initialization 1/ On/Off function /3-step dimming function:
the initialization, the sensor is not able to detect movement. 2/ 2-step dimming function:
After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it dims the light to a low light level (set by stand-by dim level). During the initialization, the sensor is not able to detect movement. Page 9 of 11 Lighting Control Switch Version: A0 10. Factory Setting 11.Application Notice Detection area: 100%, Hold Time: 5S, Stand-by Period: 0s, Stand-by dim level: 10%, Daylight Sensor: Disable 1) The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switch. 2) The sensor which installed in the plastic and glass lampshade will reduce the sensitivity.For every 3mm increase in thickness, the sensitivity will be reduced by 20%. 3) The dimming performance could be different from different 1-10v drivers. 4) The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection..Ambient lux level could be different in different environment, weather, climate, time-of-day and season. 5) The parameters of the sensor may need to be reconfigured in different installation environments. Please refer to the following instructions or contact the manufacturer. 6) This sensor is for indoor use only. It will affect the waterproof effect for outdoor use. Wind, rain, and moving objects around will cause false triggering. 7) The distance between any inductive sensors should be greater than 3m. 8) Do not place the sensor close to high-density objects such as metal, glass,concrete walls, etc, false triggering could happen. When the sensor is installed in a metal lamp, metal reflective surface, or a narrow enclosed environment, the microwave will be reflected repeatedly and cause false triggering. Please reduce the sensitivity or contact the manufacturer for technical support. etc., the sensor may generate false trigger. 9) Please ensure that there are no moving signals around the sensor, such as fan,DC motor, sewer pipe, air outlet, 10) You are advised to test 5 samples before mass application of sensor in a new lighting project. 11) Due to continuous improvement, the contents of this instruction could be changed without prior notice. Page 10 of 11 Lighting Control Switch Version: A0 11 FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. Increase the separation between the equipment and receiver. 12.Version Change Version Date Description March 14, 2019 Released new product A0 Page 11 of 11