WARNING:pdfminer.pdfpage:The PDF <_io.BufferedReader name='/Volumes/Scratch/Incoming/eg-scratch/6442751.pdf'> contains a metadata field indicating that it should not allow text extraction. Ignoring this field and proceeding. Use the check_extractable if you want to raise an error in this case Installing the ExtremeMobility AP510e Access Point Indoor 802.11 ax Table 2 Description of back ports of AP510e Overview of the AP510e The AP510e is a next generation, indoor ceiling mount model enterprise class 802.11ax access point. The e in AP510e indicates that it comes with external antennas. The AP features a dual-band radio, a band locked radio, eight RP-SMA WiFi ports, one Bluetooth port, and one internal Bluetooth Low Energy (BLE) antenna. The Bluetooth port can be used for a remote antenna in place of the internal antenna. The AP510e can be mounted on a dry or wood wall, solid flat ceiling, junction/gang box, and on a suspended or drop ceiling. Note: The AP510e requires a minimum base firmware of WiNG 7.1.1. The AP510e model has the following features:
Radios: 2 radios (1 dual band, 2.4GHz and 5GHz, and 1 band locked 5GHz); 1 IoT radio
(2.4 GHz) Console Port: RJ45 Two Ethernet Ports One multi-rate GE/2.5GE/5GE port (LAN1) with PoE In LEDs: 6 All LEDs will be on during reset. 10/100/1000 Ethernet Port (LAN2) with PoE In One Reset button Power: PoE 802.3af; 12VDC external power in connector (see Table 1 for details) Antennas:
Eight RP-SMA external antennas One RP-SMA BLE antenna One BLE internal antenna Temperature:
-20 to 50C ambient temperature anywhere Enclosure: Plastic with metal base Figure 1 Top and Side Views of AP510e 1 USB Port Table 1 AP510e Powering Methods Power Source Description Power over Ethernet (PoE) Redundant power is provided through the RJ45 Ethernet ports (LAN ports, Figure 2, items #4 and #5) of AP510e, compliant to be powered with 802.3af and provide full functionality with 802.3at. This is the preferred method of powering the AP on ceiling and high wall installations. External 12V DC power supply
(optional; ordering part
#37219 - PWR 12VDC, 3A, 2.5mm x 5.5mm connector) The AP510e can also be powered by an external DC power supply plugged into an AC source. Plug the supplys input jack into the 12V DC (Figure 2, item #2) port. Note: PoE is disabled when external power supply is used. Figure 2 AP510e back ports Number Description 1 2 3 4 5 Kensington lock 12V DC power supply Console port (Yellow) LAN 2 (GE) (Black) LAN 1 (5 GE) (Purple) LEDs Status The LEDs are located on the front face of the AP but are not visibly marked. Table 3 AP510e LED Status LED Icon LED Color Description Status GREEN AMBER Normal operational status Non-operational status GE1 Ethernet AMBER 100 Mbps GREEN 1000 Mbps PURPLE 2.5G/5G GE2 Ethernet AMBER 100 Mbps GREEN 1000 Mbps Radio #1 Status GREEN 2.4GHz AMBER WHITE Radio #2 Status AMBER 5GHz Sensor 5GHz IoT (BLE) BLUE OFF Indicates BLE is enabled Non-operational status For detailed installation information about the AP510e, see the ExtremeWireless AP510e Installation Guide. Verifying the AP510e Box Contents Verify the contents of the box and ensure that the following items are available:
Table 4 Contents of the AP510e Box Quantity Item 1 1 1 1 2 2 AP510e Quick Reference Guide Mounting bracket for 802.11ax indoor access point Cloud Quick Start Card AP510e access point Phillips pan-head wood screws Screw-in anchors Mounting and Connecting the AP Electrical Hazard: Only qualified personnel should perform installation procedures. Use these instructions as guidelines for mounting and connecting the AP510e easily and safely. The AP510e comes with a Mounting Bracket (#37201) that can be used to mount the AP on a flat t-bar with flat ceiling tiles, flat surfaces, beams, and some junction/gang boxes. An adaptor and brackets are available for mounting the AP to non-flat ceiling tiles and t-
bars. To mount the AP510e on a junction/gang box, use the optional bracket (WS-MBI-
WALL04; #30516). All additional and optional parts are sold separately. Note: The mounting procedures for installing the AP using the WS-MBI-
DCFLUSH (ordering part #37211) adaptor to a T-bar, WS-MBI-DCMTR01
(ordering part #30518) to a T-bar, and using the main mounting bracket
(ordering part #37201) along with a flat metal-easy attach adaptor (ordering part #37210), Accessory BRKT-000147A-01 (beam clip), and KT-135628-01 are covered in the ExtremeWireless AP510e Installation Guide. Mounting the AP on a Wood Wall/Solid Flat Ceiling Pre-installation checklist:
The mounting surface, item, and hardware must be able to support the AP in all environmental conditions. The mounting surface should be flat. To install the AP on a dry wall or flat surface:
Option 1: Using the Main Mounting Bracket 1 Use the mounting bracket as a template and mark the hole centers on the wall. Note: The four feet of the bracket and the direction of the arrow mark must be vertical and pointing up and the flat part of the bracket must be touching the surface it is being attached to. 2 Drill two holes 83mm (3.270) apart from each other on the wall where you want to mount the AP. 3 Insert the screws into the holes of the mounting bracket and use the screw-in anchors if needed. 4 Insert the Ethernet cables RJ45 connector into the LAN1/GE1 port. 5 Insert the AP onto the brackets four feet and slide it down to lock it in place. Note: The T-bar width can be either 9/16 (15mm) or 15/16 (24mm). Option 2: Using an optional Wall and Box bracket For detailed instructions, see the ExtremeWireless AP510e Installation Guide. Mounting the AP to a Suspended or Drop Ceiling The AP510e can be mounted to a suspended or drop ceiling directly using the mounting bracket on the t-bar. If there is a ceiling tile protrusion, add the optional T-bar adaptor to the main mounting bracket prior to T-bar installation. Option 1: Using the Main Mounting Bracket to a T-bar Before installation ensure that:
The base thickness of the T-bar that supports the ceiling tile is 0.031. The maximum base thickness of the T-bar of the T-bar is 0.055. Note: The T-bar width can be either 9/16 (15mm) or 15/16 (24mm). 1 Remove the ceiling tiles, slide and rotate the main mounting bracket onto the T-bar in such a way that the center angled locking tabs of the main bracket gets attached to the T-bar. 2 Replace the tiles to hold the T-bar in place. 3 Hold the AP and rock it back and forth to ensure it is securely mounted. 4 Attach the Ethernet cables RJ45 connector to the LAN1/GE1 port. Option 2: Mounting the AP by attaching an adaptor to the main bracket For detailed instructions, see the ExtremeWireless AP510e Installation Guide. Mounting the AP on a Junction or Gang Box For detailed procedure on Installing the AP to a Junction or Gang Box, see the ExtremeWireless AP510e Installation Guide. Mounting the AP to a Beam For detailed procedure on Installing the AP to a Beam, see the ExtremeWireless AP510e Installation Guide. Connecting a Power Supply to the AP510e If you need to power the AP510e with an external 12V DC power supply, you can plug the power cord into the power connector on the back of the AP. There is no wall mount bracket for the 12V DC power supply. When the device is powered on, the power LED on the front face of the AP is lit. Refer to the ExtremeWireless AP510e Installation Guide for information about optional power supplies. Antenna Configurations for External Antenna Models Figure 3 AP510e External RP-SMA Antenna Connectors Table 5 AP510e Antenna Configuration Software Mode Radio 1 Radio 2 Antenna Ports 2.4G/5G - 1,2,3,4 5G- 5,6,7,8 Mode 1 Mode 2 2.4 GHz Band Unlocked Sensor 5 GHz 5 GHz Dual Band 2.4/5 GHz Dual Band 2.4/5 GHz Mode 3 5 GHz 5 GHz 5 GHz None 5 GHz 5 GHz Operational Description of Antenna Configuration and RF Output Power Setting Per KDB 353028 D01 Antennas Part 15 Transmitters v01 requirement, Applications must contain an exhibit listing each antenna, the antenna gain, antenna type, and antenna manufacturer/vendor and output power that can be used for the device, that the info listed below are correct and represent the product in consideration under this filing. Professional Installation Instruction Installation personal This product is designed for specific application and needs to be installed by a qualified person who has RF and related rule knowledge. The general user shall not attempt to install or change the setting. Installation location The product shall be installed at a location where the radiating antenna can be kept 36 cm from nearby person in normal operation condition to meet regulatory RF exposure requirement. External antenna Use only the antennas which have been approved by the applicant. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC/IC limit and is prohibited. Installation procedure Refer to installation manual for additional details. Warning: Carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty. Instructions d'installation professionnelle Installation Ce produit est destine a un usage specifique et doit etre installe par un personnel qualifie maitrisant les radiofrequences et les regles s'y rapportant. L'installation et les reglages ne doivent pas etre modifies par l'utilisateur final. Emplacement d'installation En usage normal, afin de respecter les exigences reglementaires concernant l'exposition aux radiofrequences, ce produit doit etre installe de facon a respecter une distance de 36 cm entre l'antenne emettrice et les personnes. Antenn externe Utiliser uniiquement les antennes approuvees par le fabricant. L'utilisation d'autres antennes peut conduire a un niveau de rayonnement essentiel ou non essentiel depassant les niveaux limites definis par FCC/IC, ce qui est interdit. Procedure d'installation Consulter le manuel d'utilisation. Warning: Avertissement: Choisir avec soin la position d'installation et s'assurer que la puissance de sortie ne depasse pas les limites en vigueur. La violation de cette regle peut conduire a de serieuses penalites federales. Regulatory and Compliance Information Safety Guidelines This section contains notices that are intended to protect your personal safety and prevent damage to the equipment. Qualified Personnel:
Electrical Hazard: Only qualified personnel should perform installation procedures. Within the context of the safety notes in this documentation, qualified persons are defined as persons who are authorized to commission, ground and label devices, systems, and circuits in accordance with established safety practices and standards. A qualified person understands the requirements and risks involved with installing outdoor electrical equipment in accordance with national codes. Federal Communications Commission (FCC) Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver. receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 51cm between the antenna & your body. Note: This module is intended for OEM integrator. The OEM integrator is responsible for the compliance to all the rules that apply to the product into which this certified RF module is integrated. Additional testing and certification may be necessary when multiple modules are used. Industry Canada Notice This device complies with ISEDs licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d ISED applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage prjudiciable, et (2) ce dispositif doit accepter tout brouillage reu, y compris un brouillage susceptible de provoquer un fonctionnement indsirable. Caution: The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems. Caution: Avertissement: les dispositifs fonctionnant dans la bande 5150-
5250 MHz sont rservs uniquement pour une utilisation lintrieur afin de rduire les risques de brouillage prjudiciable aux systmes de satellites mobiles utilisant les mmes canaux. Warning: IC Radiation Exposure Statement: This equipment complies with IC radio-frequency exposure guidelines set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 31 cm between the antenna & your body. Warning: Dclaration d'exposition aux radiations: Cet quipement est conforme aux limites d'exposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 31 cm de distance entre la source de rayonnement et votre corps. Detachable Antenna Usage This radio transmitter [4141B-AP510E] has been approved by Innovation, Science and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device. Le prsent metteur radio [4141B-AP510E] a t approuv par Innovation, Sciences et Dveloppement conomique Canada pour fonctionner avec les types d'antenne numrs ci-dessous et ayant un gain admissible maximal d'antenne. Les types d'antennes non inclus dans cette liste qui ont un gain suprieur au gain maximal indiqu pour tout type list sont strictement interdits pour une utilisation avec cet appareil. Approved Antenna(s) list:
This device and its antenna(s) must not be co-located with any other transmitters except in accordance with IC multi-transmitter product procedures. Referring to the multi-
transmitter policy, multiple-transmitter(s) and module(s) can be operated simultaneously without reassessment permissive change. Cet appareil et son antenne (s) ne doit pas tre co-localiss ou fonctionnement en association avec une autre antenne ou transmetteur. European Waste Electrical and Electronic Equipment
(WEEE) Notice In accordance with Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE):
1 The symbol above indicates that separate collection of electrical and electronic equipment is required. 2 When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must be collected and treated separately. 3 It has been determined by the European Parliament that there are potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment. 4 It is the users responsibility to utilize the available collection system to ensure WEEE is properly treated. For information about the available collection system, contact Extreme Environmental Compliance at Green@extremenetworks.com. Hazardous Substances This product complies with the requirements of Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. Declaration of Conformity in Languages of the European Community English Finnish Dutch French Swedish Danish German Greek Icelandic Italian Spanish Portuguese Malti Hereby, Extreme Networks, declares that the radio equipment type
[AP510e] is in compliance with Directive 2014/53/EU. For full text of the EU Deceleration of Conformity, please contact Extreme Regulatory Compliance at compliancerequest@extremenetworks.com Valmistaja Extreme Networks vakuuttaa tten ett Radio LAN device tyyppinen laite on direktiivin 2014/53/EU oleellisten vaatimusten ja sit koskevien direktiivin muiden ehtojen mukainen. Hierbij verklaart Extreme Networks dat het toestel Radio LAN device in overeenstemming is met de essentile eisen en de andere relevante bepalingen van richtlijn 2014/53/EU. Par la prsente Extreme Networks dclare que l'appareil Radio LAN device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 2014/53/EU. Hrmed intygar Extreme Networks att denna Radio LAN device str I verensstmmelse med de vsentliga egenskapskrav och vriga relevanta bestmmelser som framgr av direktiv 2014/53/EU. Undertegnede Extreme Networks erklrer herved, at flgende udstyr Radio LAN device overholder de vsentlige krav og vrige relevante krav i direktiv 2014/53/EU. Hiermit erklrt Extreme Networks die bereinstimmung des "WLAN Wireless Controller bzw. Access Points" mit den grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie 2014/53/EU. Extreme Networks Radio LAN device 2014/53/
EU. Extreme Networks lysir her med yfir a thessi bunadur, Radio LAN device, uppfyllir allar grunnkrofur, sem gerdar eru i R&TTE tilskipun ESB nr 2014/53/EU. Con la presente Extreme Networks dichiara che questo Radio LAN device conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 2014/53/EU. Por medio de la presente Extreme Networks declara que el Radio LAN device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 2014/53/EU. Extreme Networks declara que este Radio LAN device est conforme com os requisitos essenciais e outras disposies da Directiva 2014/
53/EU. Hawnhekk, Extreme Networks, jiddikjara li dan Radio LAN device jikkonforma mal-htigijiet essenzjali u ma provvedimenti ohrajn relevanti li hemm fid-Dirrettiva 2014/53/EU. ExtremeMobilityTM Access Points Quick Reference AP510e-FCC AP510e-WR AP510e-FCC-TAA Scan to Download the XIQ Mobile Application Commission, monitor, and troubleshoot devices easily with XIQ Companion mobile application (supported on iOS and Android). Use your mobile device camera to scan the serial number, capture installation images, assign or change device location, and network policy. The XIQ Companion mobile application enables you to access the device CLI for troubleshooting and view device and client status. XIQ iOS Mobile App XIQ Android Mobile App Scan for Product Support Details XIQ Onboarding Documentation Copyright 2023 Extreme Networks, Inc. All Rights Reserved. Notice Legal Notices Extreme Networks, Inc. reserves the right to make changes in specifications and other information contained in this document and its website without prior notice. The reader should in all cases consult representatives of Extreme Networks to determine whether any such changes have been made. The hardware, firmware, software or any specifications described or referred to in this document are subject to change without notice. Trademarks Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks, Inc. in the United States and/or other countries. All other names (including any product names) mentioned in this document are the property of their respective owners and may be trademarks or registered trademarks of their respective companies/owners. For additional information on Extreme Networks trademarks, please see:
www.extremenetworks.com/company/legal/trademarks/
Documentation, Installation Videos, & Support For product support, including Documentation and Installation Videos, visit:
www.extremenetworks.com/documentation P/N 9035995-04 AA Note: This module is intended for OEM integrator. The OEM integrator is responsible for the compliance to all the rules that apply to the product into which this certified RF module is integrated. Additional testing and certification may be necessary when multiple modules are used. Other Countries Brazil Este produto est homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resoluo n. 242/2000 e atende aos requisitos tcnicos aplicados. Este equipamento no tem direito proteo contra interferncia prejudicial e no pode causar interferncia em sistemas devidamente autorizados. Para maiores informaes, consulte o site da ANATEL www.anatel.gov.br MPE Statement - Mobile Device This equipment complies with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range. CE Statement AT EE IT PT BE FI LV RO BG FR LT SK HR DE LU SI CY EL MT ES CZ HU NL SE DK IE PL UK All Operational Modes 2.4GHz: 802.11b, 802.11g, 802.11n (HT20), 802.11n (HT40), 802.11ac (VHT20), 802.11ac
(VHT40), Bluetooth(BR/EDR, LE) 5GHz: 802.11a, 802.11n (HT20), 802.11n (HT40), 802.11ac (VHT20), 802.11ac (VHT40), 802.11ac (VHT80), 802.11ac (VHT160) The frequency and the maximum transmitted power in EU are listed below:
2412-2472MHz: 20 dBm 2402-2480MHz (BR/EDR): 6 dBm 2402-2480MHz (LE): 8 dBm 5180-5240MHz: 23 dBm 5260-5320MHz: 23 dBm 5500-5700MHz: 30 dBm