all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 464.02 KiB | / July 02 2003 | |||
1 | Cover Letter(s) | October 02 2003 / July 02 2003 | ||||||
1 | External Photos | October 02 2003 / July 02 2003 | ||||||
1 | Internal Photos | October 02 2003 / July 02 2003 | ||||||
1 | ID Label/Location Info | October 02 2003 / July 02 2003 | ||||||
1 | Cover Letter(s) | October 02 2003 / July 02 2003 | ||||||
1 | Cover Letter(s) | October 02 2003 / July 02 2003 | ||||||
1 | Test Report | October 02 2003 / July 02 2003 | ||||||
1 | Test Setup Photos | October 02 2003 / July 02 2003 |
1 | Users Manual | Users Manual | 464.02 KiB | / July 02 2003 |
OBID classic-pro MONTAGE INSTALLATION ID CPR.M02
(deutsch / english) final public (B) 2003-02-11 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 FEIG ELECTRONIC GmbH Seite 2 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 deutsche Version ab Seite 4 english version from page 22 H C S T U E D H S I L G N E FEIG ELECTRONIC GmbH Seite 3 von 39 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage Hinweis Copyright 2002 by FEIG ELECTRONIC GmbH Lange Strae 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de ID CPR.M02 Ausgabe: er/03/02/11 - m21001-0de-id-b.doc Alle frheren Ausgaben verlieren mit dieser Ausgabe ihre Gltigkeit. Die Angaben in diesem Handbuch knnen ohne vorherige Ankndigung gendert werden. Weitergabe sowie Vervielfltigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte fr den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten. Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung fr die Richtigkeit und Vollstndigkeit der An-
gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht fr Folgeschden auf Grund fehlerhafter oder unvollstndiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bem-
hungen nie vollstndig vermeiden lassen, sind wir fr Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von gnstigsten Rahmenbedingun-
gen aus. FEIG ELECTRONIC GmbH bernimmt keine Gewhr fr die einwandfreie Funktion in systemfrem-
den Umgebungen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung dafr, dass die in diesem Dokument enthal-
tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte. OBID ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH FEIG ELECTRONIC GmbH Seite 4 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage Inhalt 1. Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen 2. Leistungsmerkmale des Readermoduls ID CPR.M02 ID CPR.M02 H C S T U E D 6 7 2.1. Leistungsmerkmale.......................................................................................................... 7 2.2. Verfgbare Modultypen.................................................................................................... 7 2.3. Lieferumfang..................................................................................................................... 7 3. Montage und Anschluss 8 3.1. Abmessungen................................................................................................................... 8 3.2. Anschluss ......................................................................................................................... 9 3.2.1. Spannungsversorgung .............................................................................................. 10 3.2.2. RS232-Schnittstelle................................................................................................... 11 3.2.3. Daten-/Taktschnittstelle............................................................................................. 12 3.2.4. Optionales Security-Modul ID SAM.M02 ................................................................... 13 3.3. Anzeigeelemente ............................................................................................................ 14 3.4. Bedienelemente.............................................................................................................. 15 3.4.1. Betriebs-/Programmier-Mode: Jumper J1.................................................................. 15 3.4.2. Nachgleich der internen Antenne: Trimmkondensator C315 ..................................... 16 3.5. Montagehinweise............................................................................................................ 18 3.5.1. Metallische Umgebung.............................................................................................. 18 3.5.2. EMV-Beeinflussung ber Zuleitungen ....................................................................... 18 3.5.3. EMV-Beeinflussung ber magnetische Felder........................................................... 19 4. Funkzulassungen 20 4.1. Europa (CE)..................................................................................................................... 20 4.2. USA (FCC)....................................................................................................................... 20 5. Technische Daten 21 FEIG ELECTRONIC GmbH Seite 5 von 39 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 1. Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Das Gert darf nur fr den vom Hersteller vorgesehenen Zweck verwendet werden. Die Bedienungsanleitung ist zugriffsfhig aufzubewahren und jedem Benutzer auszuhndigen. Unzulssige Vernderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen, die nicht vom Hersteller des Gertes verkauft oder empfohlen werden, knnen Brnde, elektri-
sche Schlge und Verletzungen verursachen. Solche Manahmen fhren daher zu einem Ausschluss der Haftung und der Hersteller bernimmt keine Gewhrleistung. Fr das Gert gelten die Gewhrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs gltigen Fassung. Fr eine ungeeignete, falsche manuelle oder automatische Ein-
stellung von Parametern fr ein Gert bzw. ungeeignete Verwendung eines Gertes wird kei-
ne Haftung bernommen. Reparaturen drfen nur vom Hersteller durchgefhrt werden. Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gert drfen nur von Elektrofachkrften mit entsprechender Ausbildung erfolgen. Vor dem ffnen des Gertes ist stets die Versorgungsspannung abzuschalten und durch Nachmessen sicherzustellen, dass das Gert spannungslos ist. Das Verlschen einer Be-
triebsanzeige ist kein Indikator dafr, dass das Gert vom Netz getrennt und spannungslos ist. Alle Arbeiten am Gert und dessen Aufstellung mssen in bereinstimmung mit den nationa-
len elektrischen Bestimmungen und den rtlichen Vorschriften durchgefhrt werden. Beim Arbeiten an dem Gert mssen die jeweils gltigen Sicherheitsvorschriften beachtet werden. FEIG ELECTRONIC GmbH Seite 6 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 H C S T U E D 2. Leistungsmerkmale des Readermoduls ID CPR.M02 2.1. Leistungsmerkmale Das Readermodul ID CPR.M02 ist fr das Lesen und Schreiben von passiven Transpondern mit einer Betriebsfrequenz von 13,56 MHz entwickelt worden. Es eignet sich fr alle Anwendungen, bei denen geringe Lesereichweiten bei kleinen Abmessungen des Readers bentigt werden. Das Modul besitzt eine integrierte Antenne, wodurch keine externen Antennenkomponenten mehr bentigt werden. 2.2. Verfgbare Modultypen Folgende Modultypen sind z.Z. verfgbar:
Modultyp ID CPR.M02-B Beschreibung Readermodul mit integrierter Antenne, RS232-C- und Daten-/Takt-
Schnittstelle, fr eine Versorgungsspannung von 5 V DC 2.3. Lieferumfang Folgende Komponenten sind im Lieferumfang enthalten:
Modultyp ID CPR.M02-B Lieferumfang 1 x Readermodul ID CPR.M02-B FEIG ELECTRONIC GmbH Seite 7 von 39 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 3. Montage und Anschluss 3.1. Abmessungen Bild 3.1-1 zeigt die Mazeichnung des Readermoduls ID CPR.M02. 50,0 44,0 X4 V2V1 3,3 X1 J1
, 0 0 5
, 0 4 4 2,1
, 1 6 2 3 , 3 X3 3,3 C405 C315 3,3
, 5 1 1
, 0 4 1 Bild 3.1-1: Mazeichnung des Readermoduls ID CPR.M02 FEIG ELECTRONIC GmbH Seite 8 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 3.2. Anschluss Bild 3.2-1 und Tabelle 3.2-1 zeigen die Belegung der Anschlustiftleiste X1. Die Stiftleiste ist fr Flachbandkabelanschlu mittels IDC-Federleiste mit Rasterma 2,54 mm ausgelegt. X1 10 9 8 7 5 3 1 6 4 2 V2V1 X4 X1 J1 X3 C405 C315 H C S T U E D Bild 3.2-1: Belegung der Anschlustiftleiste X1 X1 Pin-Nr. Kurzzeichen 1 2 3 4 5 6 7 8 9 10 DAT CLK TxD GND **
RxD
CLS VCC GND **
Beschreibung ID CPR.M02-B Datenleitung der Daten-/Taktschnittstelle Taktleitung der Daten-/Taktschnittstelle RS232-TTL Transmit Data GND RS232-TTL Receive Data Nicht angeschlossen CLS-Leitung der Daten-/Taktschnittstelle
+ 5 V DC *
GND Nicht angeschlossen Nur geregelte DC-Spannungen verwenden !
Die GND-Pins 4 und 9 sind auf dem Readermodul direkt miteinander verbunden
Tabelle 3.2-1: Belegung der Anschlustiftleiste X1 Seite 9 von 39 FEIG ELECTRONIC GmbH M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 3.2.1. Spannungsversorgung Fr die Spannungsversorgung des ID CPR.M02-A/B drfen nur geregelte DC-Spannungen ver-
wendet werden. Im Falle von getakteten Netzteilen zur Versorgung des Moduls ist auf eine ausreichende Filterung der Versorgungsspannung zu achten. Strungen der Versorgungsspannung knnen sich in einer Reduzierung der Lese- und Schreib-
reichweite des Modules auswirken. Die Lnge des Zuleitungskabels der Spannungsversorgung sollte mglichst kurz sein. Sie darf 3 m nicht berschreiten. X1 Pin-Nr. Kurzzeichen 8 9, 4 VCC *
GND **
Beschreibung ID CPR.M02-B
+ 5 V DC 5%
GND
* Nur geregelte DC-Spannungen verwenden !
** Die GND-Pins 4 und 9 sind auf dem Readermodul direkt miteinander verbunden Tabelle 3.2.1-1: Pinbelegung der Spannungsversorgung an X1 HINWEIS:
Eine Verpolung der Versorgungsspannung kann zur Zerstrung des Gertes fhren. Versorgungsspannungen auerhalb der Spezifikation knnen zur Zerstrung des Ger-
tes fhren. FEIG ELECTRONIC GmbH Seite 10 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 H C S T U E D 3.2.2. RS232-Schnittstelle Die Lnge des Zuleitungskabels der RS232-Schnittstelle sollte mglichst kurz sein. Sie darf 3 m nicht berschreiten. X1 Pin-Nr. 3 4, 9 5 Kurzzeichen Beschreibung ID CPR.M02-B TxD *
GND **
RxD *
RS232-TTL - Transmit Data GND RS232-TTL - Receive Data
* Bezeichnungen der Signale aus Sichtweise des Readermoduls.
** Die GND-Pins 4 und 9 sind auf dem Readermodul direkt miteinander verbunden Tabelle 3.2.2-1: Pinbelegung der RS232-Schnittstelle an X1 Die bertragungsparameter der Schnittstelle knnen per Softwareprotokoll konfiguriert werden. Tabelle 3.2.2-2 zeigt die Standardparameter der RS232-Schnittstelle. Parameter Baudrate Anzahl der Datenbits Paritt Anzahl der Stoppbits Standardeinstellung 38400 8 Even 1 Tabelle 3.2.2-2: Standardparameter der RS232-Schnittstelle. FEIG ELECTRONIC GmbH Seite 11 von 39 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 3.2.3. Daten-/Taktschnittstelle Die Lnge des Zuleitungskabels der Daten-/Taktschnittstelle sollte mglichst kurz sein. Sie darf 3 m nicht berschreiten. X1 Pin-Nr. Kurzzeichen 1 2 7 DAT CLK CLS 4, 9 GND *
Beschreibung ID CPR.M02-B Datenleitung der Daten-/Taktschnittstelle Taktleitung der Daten-/Taktschnittstelle CLS-Leitung der Daten-/Taktschnittstelle GND
* Die GND-Pins 4 und 9 sind auf dem Readermodul direkt miteinander verbunden Tabelle 3.2.3-1: Pinbelegung der RS232-Schnittstelle an X1 Host Data Clock CLS GND DAT CLK CLS GND ID CPR.M02 Bild 3.2.3-1: Anschlu der Daten-/Taktschnittstelle FEIG ELECTRONIC GmbH Seite 12 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 H C S T U E D 3.2.4. Optionales Security-Modul ID SAM.M02 Bei Bedarf kann optional auf die Stiftleisten X3 und X4 ein Security-Modul vom Typ ID SAM.M02 aufgesteckt werden. Das Security-Modul ID SAM.M02 bietet zustzliche Sicherheit durch kryptographische Datenber-
tragung zwischen Reader und Transponder. V1 V2 X4 X1
, 0 0 5 C315 X3 25,0 0
, 0 1 5
, 1 1 Bild 3.2.4-1: Mazeichnung ID CPR.M02 mit ID SAM.M02 FEIG ELECTRONIC GmbH Seite 13 von 39 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 3.3. Anzeigeelemente Das Readermodul ID CPR.M02 besitzt eine grne LED (V1) und eine rote LED (V2) als Anzeige-
elemente (siehe Bild 3.3-1). V1 V2 X4 X1 J1 Bild 3.3-1: Position der LEDs V1 und V2 Die Funktionen der beiden LEDs knnen per Softwareprotokoll konfiguriert werden. Ergnzend dazu besteht auch die Mglichkeit beide LEDs direkt durch ein weiteres Softwareprotokoll anzu-
steuern. Tabelle 3.3-1 zeigt die Standardeinstellung von V1 und V2. LED Farbe V1 Grn Standardeinstellung Blinkt nach einem Reset vier mal. Blinkt kontinuierich mit einer Frequenz von V2 Rot 2 Hz. Blinkt nach einem Reset vier mal. Leuchtet nach einer erfolgreichen Kommunikation mit einem Transponder fr 1 Sekunde. Tabelle 3.3-1: Standardeinstellung der LEDs FEIG ELECTRONIC GmbH Seite 14 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 H C S T U E D 3.4. Bedienelemente 3.4.1. Betriebs-/Programmier-Mode: Jumper J1 Der Jumper J1 dient zur Konfiguration des Betriebs- bzw. Programmier-Mode des ID CPR.M02. Im Standardbetrieb ist der Jumper auf die Position 1-2 gesteckt (siehe Bild 3.4.1-1). Der Reader befindet sich dann im normalen Betriebsmode. Wird der Jumper auf die Position 2-3 gesteckt, so startet nach einem Reset der integrierte Hardware Bootloader. Da die Firmware des Readers jedoch auch ber einen Software Bootloader verfgt, sollte die Option des Hardware Bootloaders nur fr die Installation des Software Boot-
loaders gewhlt werden. Nheres zum Programmieren des Readers kann in der entsprechenden Application Note
"Firmware Update" nachgelesen werden. Jumperposition 1 - 2 2 - 3 Mode Standardeinstellung :
Der Reader befindet sich im normalen Betriebsmode. Aktivierung des Hardware-Bootloaders :
Nach einem Reset startet die CPU des Readers seinen Hardware Bootloader und kann ber diesen neu programmiert werden. Tabelle 3.4.1-1: Jumper J1 J1 3 2 1 Standard-
einstellung V2V1 X4 X1 J1 X3 C405 C315 Bild 3.4.1-1: Jumper J1 FEIG ELECTRONIC GmbH Seite 15 von 39 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 3.4.2. Nachgleich der internen Antenne: Trimmkondensator C315 Die Antenne des ID CPR.M02 kann durch verschiedene Umgebungseinflsse wie zum Beispiel Metalle verstimmt werden (siehe Kapitel 3.5). Diese Verstimmungen knnen in einem gewissen Rahmen durch den Trimmkondensator C315 ausgeglichen werden. V2V1 X4 X1 J1 X3 C405 C315 Trimmkondensator C405:
NICHT VERNDERN !!!
Trimmkondensator C315:
Nachgleich der internen Antenne Bild 3.4.3-1: Trimmkondensator zum Nachgleich der Antenne Der Nachgleich der integrierten Antenne kann mit Hilfe eines Oszilloskopes (Bandbreite 20 MHz) durchgefhrt werden. Dazu wird der GND-Anschlu des Oszilloskoptastkopfes mit der Tastkopf-
spitze kurzgeschlossen und anschlieend ber die Leiterplatte des ID CPR.M02 gehalten. Der Tastkopf bildet so eine Meschleife fr das abgestrahlte magnetische Feld des ID CPR.M02. Der Abstand zwischen Oszilloskoptastkopf und ID CPR.M02 sollte im Bereich 0 bis 3 cm liegen. Nun mu mit Hilfe des Software-Kommandos "RF-ON" (0x6A) das HF-Feld des ID CPR.M02 eingeschaltet werden. Auf dem Bildschirm des Oszilloskopes sollte anschlieend ein 13,56 MHz-
Signal zu sehen sein. Fr den Abgleich der internen Antenne mu nun die Signalamplitude des 13,56 MHz-Signals mit Hilfe des Trimmkondensators C315 auf Maximum abgeglichen werden. Mit C315 Signalamplitude auf Maximum drehen ID CPR.M02 V1 V2 X1 C65 Bild 3.4.3-2: Meaufbau zum Abgleich der internen Antenne FEIG ELECTRONIC GmbH Seite 16 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 H C S T U E D Wird der maximale Wert der Signalamplitude bei der Minimum- oder Maximumposition des Trimm-
kondensators erreicht (Bild 3.4.3-3), so ist Vorsicht geboten. In diesem Fall ist meist die Verstim-
mung der Antenne durch die Umgebung zu gro und kann durch den Trimmkondensator nicht vollstndig ausgeglichen werden. Beschriftung Minimale Kapazitt Maximale Kapazitt Bild 3.4.3-3: Minimal- und Maximalposition des Trimmkondensators C315 Im Anschluss an den Abgleichvorgang sollte die Antenne noch einmal auf ihre maximale Reich-
weite und eventuelle Kommunikationslcher untersucht werden. HINWEIS:
Trotz der hier beschriebenen Mglichkeit des Antennennachgleichs sollte der Abstand zwischen Reader und den umgebenden Metallflchen mindestens 3 cm betragen. Dabei sollte bedacht werden, dass sich auch andere Leiterplatten, je nach Kupferauflage, wie Metallflchen verhalten. FEIG ELECTRONIC GmbH Seite 17 von 39 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 3.5. Montagehinweise Folgende mgliche Beeinflussungen durch die Umgebung sollten beim Einbau eines ID CPR.M02 in ein anderes Gert beachtet werden :
Beeinflussung durch eine metallische Umgebung Verstimmung der integrierten Antenne Beeintrchtigung der Ausbreitung des magnetischen Feldes der Antenne EMV-Beeinflussung ber Zuleitungen Beeintrchtigung der Kommunikation zwischen Reader und Transponder EMV-Beeinflussungen ber magnetische Felder Beeintrchtigung der Kommunikation zwischen Reader und Transponder 3.5.1. Metallische Umgebung Beim Einbau eines ID CPR.M02 in ein anderes Gert ist darauf zu achten, dass sich mglichst keine Metallflchen bzw. Metallteile in der direkten Umgebung des Readers befinden. Diese kn-
nen die Antenne verstimmen und so das magnetische Feld der integrierten Antenne reduzieren. Dies wirkt sich dann in einer reduzierten Lesereichweite des Readers aus. Der Abstand zwischen Reader und Metallflche sollte mindestens 3 cm betragen. Dabei sollte bedacht werden, dass sich auch andere Leiterplatten, je nach Kupferauflage, wie Me-
tallflchen verhalten. Ist eine metallische Umgebung nicht zu vermeiden, so sollten die Abstnde im Interesse der sta-
bilen Funktion jedoch so gro wie nur irgend mglich gewhlt werden. Auch der Bereich zwischen Antenne und Transponder, sowie der Bereich auf der anderen Seite des Transponders sollte frei von Metallteilen sein. Da jede Vernderung der metallischen Umgebung zu einer Verstimmung der integrierten Antenne und dadurch einer Beeintrchtigung der Funktion fhrt, sollten sich keine beweglichen Metallteile, wie z.B. metallische Lfter, in der Nhe des Readers befinden. 3.5.2. EMV-Beeinflussung ber Zuleitungen Trotz der internen EMV-Filter innerhalb des Readers kann es durch starke Strungen auf der Spannungsversorgung zu Beeintrchtigungen der Kommunikation zwischen Reader und Transponder kommen. Dabei wird vor allem der Empfang der Rckantwort des Transponders ge-
strt. Beim Einbau eines ID CPR.M02 in ein anderes Gert sollte daher auf eine mglichst saubere, strfreie Spannungsversorgung geachtet werden. FEIG ELECTRONIC GmbH Seite 18 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 3.5.3. EMV-Beeinflussung ber magnetische Felder Da im vorliegenden Fall der RF-ID-Technik die Kommunikation zwischen Reader und Transponder mittels der Modulation eines magnetischen Feldes abluft, knnen sich magnetische Wechselfel-
der in der Nhe der Antenne negativ auf dessen Funktion auswirken. Zu den Quellen solcher magnetischen Strfelder gehren zum Beispiel Spulen innerhalb eines primr oder sekundr getakteten Netzteils. Bei der Festlegung der Position von Reader und Antenne in einem Gert sollte dieses auf eventu-
elle Strquelle in der oben angegebenen Form untersucht werden. Notfalls sind Abschirmma-
nahmen zur Unterdrckung einer solchen Strquelle anzuwenden. H C S T U E D FEIG ELECTRONIC GmbH Seite 19 von 39 M21001-0de-ID-B.doc H C S T U E D OBID classic-pro Montage ID CPR.M02 4. Funkzulassungen 4.1. Europa (CE) Die Funkanlage entspricht, bei bestimmungsgemer Verwendung den grundlegenden Anforde-
rungen des Artikels 3 und den brigen einschlgigen Bestimmungen der R&TTE Richtlinie 1999/5/E6 vom Mrz 99. 4.2. USA (FCC) FCC ID: PJMCPRM02 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communica-
tions Commission Rules permitting the operation of this device. This device is labeled with an FCC ID number. If this label is not visible when installed in an end device, the outside of the device MUST also display a label referring to the enclosed module. Wording on the label similar to the following shall be used:
This device contains transmitter module FCC ID PJMCPRM02 At the time of this printing, the antennas listed below were the only antennas approved for use with the ID CPR.M02 module. Use of other antennas must be approved by FEIG ELECTRONIC GmbH. Antennas approved: ID ISC.ANT100100; ID ISC.ANT4030 FEIG ELECTRONIC GmbH Seite 20 von 39 M21001-0de-ID-B.doc OBID classic-pro Montage ID CPR.M02 H C S T U E D 5. Technische Daten Mechanische Daten Abmessungen ( B x H x T ) Anschlussstecker Elektrische Daten Spannungsversorgung Version B Leistungsaufnahme Betriebsfrequenz Sendeleistung Antenne Schnittstellen Version B Funktionelle Eigenschaften EEPROM (fr Parameter) FLASH Untersttzte Transponder Optische Anzeigen Umgebungsbedingungen Temperaturbereich Betrieb Lagerung Angewendete Normen Zulassung Funk Europa USA EMV Sicherheit 50mm x 50mm x 14 mm 10 polige Stiftleiste mit Rasterma 2,54mm 5 V DC 5%
max. 1,5 W 13.56 MHz 250 mW 2 dB Interne Antenne, 48mm x 48mm RS232 - TTL-Level, Daten-/Taktschnittstelle 1 kB
(10,000 Schreibzyklen) 64 kB
(Softwareupdate ber Schnittstelle mglich) ISO15693 (ICode SLI, Tag-It HFI, my-d, STM LRI512), ICode 1, ISO14443-A, ISO14443-B Optional:
SAM (Security Access Module), z.B. fr my-d vicinity und my-d proximity 2 LEDs
-20C bis +70C
-40C bis +85C EN 300 330 FCC 47 CFR Part 15 EN 301 489 EN 60950 FEIG ELECTRONIC GmbH Seite 21 von 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation Note Copyright 2002 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de ID CPR.M02 Edition: er/03/02/11 - m21001-0de-id-b.doc With the edition of this manual, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID is registered trademark of FEIG ELECTRONIC GmbH. Page 22 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation Contents 6. Safety Instructions / Warning - Read before start-up !
7. Performance Characteristics of the ID CPR.M02 Reader ID CPR.M02 24 25 H S I L G N E 7.1. Performance Characteristics......................................................................................... 25 7.2. Available module types.................................................................................................. 25 7.3. Scope of delivery............................................................................................................ 25 8. Installation and wiring 26 8.1. Dimensions..................................................................................................................... 26 8.2. Wiring.............................................................................................................................. 27 8.2.1. Supply voltage .......................................................................................................... 28 8.2.2. RS232 interface ........................................................................................................ 29 8.2.3. Data/Clock interface.................................................................................................. 30 8.2.4. Optional Security Module ID SAM.M02 ..................................................................... 31 8.3. Display elements ............................................................................................................ 32 8.4. Operating elements........................................................................................................ 33 8.4.1. Operating/Programming Mode: Jumper J1................................................................ 33 8.4.2. Retuning the internal antenna: Trim capacitor C315.................................................. 34 8.5. Installation notes............................................................................................................ 36 8.5.1. Metallic surroundings ................................................................................................ 36 8.5.2. EMC effects on cables .............................................................................................. 36 8.5.3. EMC effects from magnetic fields.............................................................................. 37 9. Radio Approvals 38 9.1. Europe (CE)..................................................................................................................... 38 9.2. USA (FCC)....................................................................................................................... 38 10. Technical Data 39 FEIG ELECTRONIC GmbH Page 23 of 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation ID CPR.M02 6. Safety Instructions / Warning - Read before start-up !
The device has to be used only for the purpose designed by the manufacturer. The operation manual has to be stored available at any time and has to be handed over to each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such measures will lead to exclusion of any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer is not legally responsible for incorrect, unsuitable manual or automatical setting of parameters for a device or the incorrect application of a device. Repairs can only be executed by the manufacturer. Installation-, operation- and maintenance procedures should only be carried out by qualified personnel. Before opening the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. CAUTION! The fading of an operation control (LED) is no indicator for an interrupted power supply or the device being without voltage!
Works at the device and its installation have to be executed according to the national legal requirements and local prescriptions. When working on devices the valid safety regulations must be observed. Page 24 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation ID CPR.M02 7. Performance Characteristics of the ID CPR.M02 Reader 7.1. Performance Characteristics The ID CPR.M02 Reader Module is designed for reading and writing passive transponders having an operating frequency of 13.56 MHz. It is suitable for any application in which short read ranges and small reader dimensions are required. The module has an integrated antenna, eliminating the need for any external antenna components. 7.2. Available module types The following module types are currently available:
Module type ID CPR.M02-B Description Reader Module with integrated antenna, RS232-C and data/clock in-
terface, for a supply voltage of 5 V DC 7.3. Scope of delivery The following components are included:
Module type ID CPR.M02-B Included 1 x Reader Module ID CPR.M02-B H S I L G N E FEIG ELECTRONIC GmbH Page 25 of 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation ID CPR.M02 8. Installation and wiring 8.1. Dimensions Fig. 3.1-1 shows the dimensions of the ID CPR.M02 Reader Module 50,0 44,0 X4 V2V1 3,3 X1 J1
, 0 0 5
, 0 4 4 2,1
, 1 6 2 3 , 3 X3 3,3 C405 C315 3,3
, 5 1 1
, 0 4 1 Fig. 3.1-1: Dimensions of the ID CPR.M02 Reader Module Page 26 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation ID CPR.M02 8.2. Wiring Fig. 3.2-1 and Table 3.2-1 show the pin assignments for Terminal X1. The pin connector is de-
signed for flat cable connection using an IDC multipoint socket connector with 2.54 mm pin spac-
ing. X1 10 9 8 7 5 3 1 6 4 2 V2V1 X4 X1 J1 X3 C405 C315 H S I L G N E Fig. 3.2-1: Pin assignments for Terminal X1 X1 Pin no. Function Description ID CPR.M02-B 1 2 3 4 5 6 7 8 9 10 DAT CLK TxD GND **
RxD
CLS VCC GND **
Data line for the data/clock interface Clock line for the data/clock interface RS232-TTL Transmit Data GND RS232-TTL Receive Data not connected CLS line for the data/clock interface
+ 5 V DC *
GND not connected Use only regulated DC power supplies !
GND-Pins 4 and 9 are to be connected directly to each other
on the Reader Module Table 3.2-1: Pin assignments for Terminal X1 FEIG ELECTRONIC GmbH Page 27 of 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation ID CPR.M02 8.2.1. Supply voltage The ID CPR.M02-A/B must be supplied only by a regulated power supply. If switching power supplies are used with the module, be sure that there is adequate filtering. Noise from the power supply can result in a reduction of the read/write range of the module. The cable length from the power supply should be as short as possible, and should in any case not exceed 3 m. X1 Pin no. 8 9, 4 Function VCC *
GND **
Description ID CPR.M02-B
+ 5 V DC 5%
GND
* Use only regulated power supplies !
** GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.1-1: Pin assignments for X1 NOTE:
Reversing the polarity of the supply voltage may destroy the device. Supply voltages outside the specifications may destroy the device. Page 28 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation ID CPR.M02 8.2.2. RS232 interface The length of the cable to the RS232 interface should be kept as short as possible, and must in any case not exceed 3 m. H S I L G N E X1 Pin no. 3 4, 9 5 Function TxD *
GND **
RxD *
Description ID CPR.M02-B RS232-TTL - Transmit Data GND RS232-TTL - Receive Data
* Signal names as seen by the Reader Module.
** GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.2-1: Pin assignments for the RS232 interface on X1 The transmission parameters for the interface can be software-configured. Table 3.2.2-2 shows the standard parameters for the RS232 interface. Parameter Baud rate No. of data bits Parity No. of stop bits Standard setting 38400 8 Even 1 Table 3.2.2-2: Standard parameters of the RS232 interface. FEIG ELECTRONIC GmbH Page 29 of 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation ID CPR.M02 8.2.3. Data/Clock interface The length of the cable to the data/clock interface should be kept as short as possible. It must not exceed 3 m. X1 Pin no. Function Description ID CPR.M02-B 1 2 7 DAT CLK CLS 4, 9 GND *
Data line for the data/clock in-
terface Clock line for the data/clock interface CLS line for the data/clock in-
terface GND
* GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.3-1: Pin configuration for the RS232 interface on Terminal X1 Host Data Clock CLS GND DAT CLK CLS GND ID CPR.M02 Fig. 3.2.3-1: Connecting the data/clock interface Page 30 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation ID CPR.M02 8.2.4. Optional Security Module ID SAM.M02 If needed, the optional ID SAM.M02 Security Module can be connected to terminals X3 and X4. The ID SAM.M02 Security Module provided additional security by using cryptographic data trans-
mission between the reader and transponder. H S I L G N E V1 V2 X4 X1
, 0 0 5 C315 X3 25,0
, 0 0 1
, 5 1 1 Fig. 3.2.4-1: Dimensions of ID CPR.M02 with ID SAM.M02 FEIG ELECTRONIC GmbH Page 31 of 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation ID CPR.M02 8.3. Display elements The ID CPR.M02 Reader Module has a green LED (V1) and a red LED (V2) which are used as display elements (Fig. 3.3-1). V1 V2 X4 X1 J1 Fig. 3.3-1: Position of LEDs V1 and V2 The functions of both LEDs can be configured using software protocol. It is also possible to control both LEDs directly using an additional software protocol. Table 3.3-1 shows the standard setting for V1 and V2. LED Color V1 V2 Green Red Standard setting Flashes 4x after a reset. Flashes continuously at a frequency of 2 Hz. Flashes 4x after a reset. Comes on for 1 second after successful communication with a transponder. Table 3.3-1: Standard setting for the LEDs Page 32 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation ID CPR.M02 H S I L G N E 8.4. Operating elements 8.4.1. Operating/Programming Mode: Jumper J1 Jumper J1 is used to configure the operating and programming mode of the ID CPR.M02. In standard operation the jumper is set to Position 1-2 (see Fig. 4.3.1-1). The reader is then in normal operating mode. If the jumper is set to Position 2-3, the integrated hardware bootloader starts after a reset. Since the readers firmware however also has a software bootloader, the hardware bootloader option should be used only for installing the software bootloader. For additional information about programming the reader, see the corresponding Application Note Firmware Update. Jumper position 1 - 2 2 - 3 Mode Standard setting :
The reader is in normal operating mode. Activation of the hardware bootloader:
After a reset the readers CPU starts its hardware bootloader, which can then be used for new pro-
gramming. Table 3.4.1-1: Jumper J1 J1 3 2 1 Standard-
einstellung V1 V2 X4 X1 J1 X3 C73 J2 X2 J3 C65 Fig. 3.4.1-1: Jumper J1 FEIG ELECTRONIC GmbH Page 33 of 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation ID CPR.M02 8.4.2. Retuning the internal antenna: Trim capacitor C315 The antenna of the ID CPR.M02 can be detuned as a result of various ambient conditions such as nearby metal objects (see Section 8.5). This detuning can be compensated to some degree using the trim capacitor C315. V2V1 X4 X1 J1 X3 C405 C315 Trim capacitor C405:
DO NOT CHANGE !!!
Trim capacitor C315:
Retuning the internal antenna Fig. 3.4.3-1: Trim capacitor for retuning the antenna The integrated antenna can be retuned with the aid of an oscilloscope (bandwidth 20 MHz). To do this, short the GND terminal of the oscilloscope probe with the probe point and hold it over the circuit board of the ID CPR.M02. The probe then forms a measuring loop for the radiated magnetic field of the ID CPR.M02. The distance between the oscilloscope probe and the ID CPR.M02 should be between 0 and 3 cm. Use the software command RF-ON (0x6A) to turn on the HF field of the ID CPR.M02. A 13.56 MHz signal should be visible on the oscilloscope screen. To tune the internal antenna, now set the signal amplitude of the 13.56 MHz signal to maximum using trim capacitor C315. Turn C315 to set am-
Mit C315 Signalamplitude auf plitude to maximum Maximum drehen ID CPR.M02 V1 V2 X1 C65 Fig. 3.4.3-2: Configuration for tuning the internal antenna Page 34 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation ID CPR.M02 Use caution when the maximum value of the signal amplitude is reached at the minimum or maxi-
mum position of the trim capacitor (Fig. 3.4.3-3). This usually means the antenna is too severely detuned by the surroundings and can no longer be fully compensated by the trim capacitor. Labeling Beschriftung H S I L G N E Minimum Minimale Kapazitt capacitance Maximum Maximale Kapazitt capacitance Fig. 3.4.3-3: Minimum and maximum position of the trim capacitor C315 After the antenna has bee tuned, check it again for maximum range and any communication gaps. NOTE:
Notwithstanding the possibility of retuning the antenna as described here, the distance between the reader and the surrounding metal surfaces must be at least 3 cm. Note that even other circuit boards may act like metal objects depending on how much copper they contain. FEIG ELECTRONIC GmbH Page 35 of 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation ID CPR.M02 8.5. Installation notes Be aware of the following possible environmental factors when installing an ID CPR.M02 into an-
other device :
Effects from nearby metal objects Detuning of the integrated antenna Impaired propagation of the antennas magnetic field EMC effects on cables Impaired communication between reader and transponder EMC effects from magnetic fields Impaired communication between reader and transponder 8.5.1. Metallic surroundings When installing an ID CPR.M02 into another device, be sure that there are no metal surfaces or objects in the direct vicinity of the reader if possible. These can detune the antenna and thus re-
duce the magnetic field of the integrated antenna. This will in turn result in reduced read distances for the reader. The distance between the reader and a metal surface should be at least 3 cm. Note that even other circuit boards may act line metal objects depending on how much copper they contain. If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping the distance as great as possible. The area between the antenna and transponder as well as the area on the other side of the trans-
ponder should also be kept clear of metal parts. Since any change in the metallic environment will result in detuning of the integrated antenna and therefore to impaired function, no moving metal parts, such as metallic fans, should be allowed in the vicinity of the reader. 8.5.2. EMC effects on cables In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can result in impairment of the communication between the reader and transponder. When installing an ID CPR.M02 into another device, be sure therefore that a clean, noise-free power supply is used. Page 36 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation ID CPR.M02 8.5.3. EMC effects from magnetic fields Since in this type of RF-ID-Technology the communication between the reader and transponder takes place by modulation of a magnetic field, alternating magnetic fields in the vicinity of the an-
tenna can have a negative impact on its function. Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. When determining the position of the reader and antenna within a device, check the device for any possible sources of interference as described above. If necessary, use shielding to suppress such interference. H S I L G N E FEIG ELECTRONIC GmbH Page 37 of 39 M21001-0de-ID-B.doc H S I L G N E OBID classic-pro Installation ID CPR.M02 9. Radio Approvals 9.1. Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. 9.2. USA (FCC) FCC ID: PJMCPRM02 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communica-
tions Commission Rules permitting the operation of this device. This device is labeled with an FCC ID number. If this label is not visible when installed in an end device, the outside of the device MUST also display a label referring to the enclosed module. Wording on the label similar to the following shall be used:
This device contains transmitter module FCC ID PJMCPRM02 At the time of this printing, the antennas listed below were the only antennas approved for use with the ID CPR.M02 module. Use of other antennas must be approved by FEIG ELECTRONIC GmbH. Antennas approved: ID ISC.ANT100100; ID ISC.ANT4030 Page 38 of 39 FEIG ELECTRONIC GmbH OBID classic-pro Installation ID CPR.M02 H S I L G N E 10. Technical Data Mechanical Data Dimensions ( W x H x D ) Connector Electrical Data Supply voltage Version B Power Consumption Operating Frequency RF Transmitting Power Antenna Interfaces Version B Functional Characteristics EEPROM (for parameters) FLASH Supported Transponders 50mm x 50mm x 14 mm 10 pol. Pin-Connector 5 V DC 5%
max. 1,5 W 13.56 MHz 250 mW 2 dB Internal Antenna, 48mm x 48mm RS232 Level TTL, Data Clock Interface 1 kB
(10,000 write cycles) 64 kB
(software update on interface possible) ISO15693 (ICode SLI, Tag-It HFI, my-d, STM LRI512), ICode 1, ISO14443-A, ISO14443-B Optional:
SAM (Security Access Module), e.g. for my-d vicinity and my-d proximity Optical Indicators 2 LEDs Ambient Temperature Range Operating Storage Applicable Norms Radio Approval Europe USA EMC Safety
-20C to +70C
-40C to +85C EN 300 330 FCC 47 CFR Part 15 EN 301 489 EN 60950 FEIG ELECTRONIC GmbH Page 39 of 39 M21001-0de-ID-B.doc
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2003-02-07 | 13.56 ~ 13.56 | DXT - Part 15 Low Power Transceiver, Rx Verified | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2003-02-07
|
||||
1 | Applicant's complete, legal business name |
Feig Electronic GmbH
|
||||
1 | FCC Registration Number (FRN) |
0007634793
|
||||
1 | Physical Address |
Lange Strae 4
|
||||
1 |
Weilburg-Waldhausen, N/A D-35781
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
b******@phoenix-test-lab.de
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
PJM
|
||||
1 | Equipment Product Code |
CPRM02
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
E******** R********
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
+49 6********
|
||||
1 | Fax Number |
+49 6********
|
||||
1 |
e******@feig.de
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Senton GmbH
|
||||
1 | Name |
J****** R****
|
||||
1 | Physical Address |
Aeussere Fruehlingsstrasse 45
|
||||
1 |
Straubing, D-94315
|
|||||
1 |
Germany
|
|||||
1 | Telephone Number |
+49 9********
|
||||
1 | Fax Number |
+49 9********
|
||||
1 |
j******@senton.de
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Senton GmbH
|
||||
1 | Name |
J******** R********
|
||||
1 | Physical Address |
Aeussere Fruehlingsstrasse 45
|
||||
1 |
Straubing, D-94315
|
|||||
1 |
Germany
|
|||||
1 | Telephone Number |
+49 9********
|
||||
1 | Fax Number |
+49 9********
|
||||
1 |
j******@senton.de
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXT - Part 15 Low Power Transceiver, Rx Verified | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Inductive Tag Reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | This device was certified as a modular transmitter. Transmitter module is authorized for use with antennas, as documented in the filing. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUV SUD Product Service GmbH PS-EMC-STR
|
||||
1 | Name |
R**** H******
|
||||
1 | Telephone Number |
49-09********
|
||||
1 | Fax Number |
49-09********
|
||||
1 |
r******@tuev-sued.de
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 13.56000000 | 13.56000000 | 0.0100000000 % |