OBID classic-pro Installation ID CPR.M02/ANT19 ID CPR.M02/ANT19 ID CPR.M02.VP/AB-CA with ID ICS.ANT19
(english) FEIG ELECTRONIC GmbH Page 2 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 Note Copyright 2002 - 2006 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de Edition: bs/07/10/30 - manual-m21001-3de-id-b.doc With the edition of this manual, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID i-scan is a registered trademark of FEIG ELECTRONIC GmbH. I-CODE and mifare is a registered trademark of Philips Electronics N.V. my-d is a registered trademark of Infineon Technologies AG Tag-itTM is a registered trademark of Texas Instruments Incorporated FEIG ELECTRONIC GmbH Page 3 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation Contents ID CPR.M02/ANT19 1. Safety Instructions / Warning - Read before start-up !
2. Performance Characteristics of the ID CPR.M02 Reader 5 6 2.1. Performance Characteristics .............................................................................................6 2.2. Available module and antenna types ................................................................................6 2.3. Scope of delivery.................................................................................................................6 3. Installation and wiring 7 3.1. Dimensions..........................................................................................................................7 3.2. Wiring ...................................................................................................................................8 3.2.1. Supply voltage ...............................................................................................................9 3.2.2. RS232 interface...........................................................................................................10 3.2.3. Data/Clock interface ....................................................................................................11 3.2.4. Connection of an external Antenna (ID ISC.ANT19) ...................................................12 3.2.5. Optional Module ID SAM.M02 .....................................................................................13 3.3. Display elements...............................................................................................................14 3.4. Operating elements...........................................................................................................15 3.4.1. Operating/Programming Mode: Jumper J1..................................................................15 3.4.2. Retuning the internal antenna (ID CPR.M02.VP/AB-C)...............................................16 3.5. Installation notes...............................................................................................................18 3.5.1. Metallic surroundings...................................................................................................18 3.5.2. EMC effects on cables.................................................................................................18 3.5.3. EMC effects from magnetic fields................................................................................19 4. Radio Approvals 20 4.1. Europe (CE)........................................................................................................................20 4.2. USA (FCC)..........................................................................................................................20 5. Technical Data 21 FEIG ELECTRONIC GmbH Page 4 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 1. Safety Instructions / Warning - Read before start-up !
The device has to be used only for the purpose designed by the manufacturer. The operation manual has to be stored available at any time and has to be handed over to each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such measures will lead to exclusion of any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer is not legally responsible for incorrect, unsuitable manual or automatical setting of parameters for a device or the incorrect application of a device. Repairs can only be executed by the manufacturer. Installation-, operation- and maintenance procedures should only be carried out by qualified personnel. Before opening the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. CAUTION! The fading of an operation control (LED) is no indicator for an interrupted power supply or the device being without voltage!
Works at the device and its installation have to be executed according to the national legal requirements and local prescriptions. When working on devices the valid safety regulations must be observed. FEIG ELECTRONIC GmbH Page 5 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 2. Performance Characteristics of the ID CPR.M02 Reader 2.1. Performance Characteristics The ID CPR.M02 Reader Module is designed for reading and writing passive transponders having an operating frequency of 13.56 MHz. It is suitable for any application in which short read ranges and small reader dimensions are required. 2.2. Available module and antenna types The following module types are currently available:
Modul Type Power Supply Antenna ID CPR.M02.VP/AB-C ID CPR.M02.VP/AB-CA 5 V DC internal external RS232-TTL Interface 4.800, 9.600, 19.200, 38.400, 57.600, 115.200, 230.400 Baud Data-/Clock Interface Mag. Stripe Wiegand The following antenna types are currently available:
Antenna ID ISC.ANT19 PCB- Antenna, 50, 19mm Description 2.3. Scope of delivery The following components are included:
Modul Type ID CPR.M02.VP/AB-C ID CPR.M02.VP/AB-CA 1 x Reader Module ID CPR.M02.VP/AB-C 1 x Reader Module ID CPR.M02.VP/AB-CA Included FEIG ELECTRONIC GmbH Page 6 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3. Installation and wiring 3.1. Dimensions Fig. 3.1-1 shows the dimensions of the ID CPR.M02 Reader Module 50,0 44,0 X4 V2V1 3,3 X1 J1
, 0 0 5
, 0 4 4 2,1
, 1 6 2 3 , 3 X3 3,3 C405 X2 C315 3,3 3,5
, 0 4 2
, 5 1 1
, 0 4 1 Fig. 3.1-1: Dimensions of the ID CPR.M02 Reader Module FEIG ELECTRONIC GmbH Page 7 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.2. Wiring Fig. 3.2-1 and Table 3.2-1 show the pin assignments for Terminal X1. The pin connector is de-
signed for flat cable connection using an IDC multipoint socket connector with 2.54 mm pin spac-
ing. X1 9 10 8 6 4 2 7 5 3 1 V2V1 X4 X1 J1 X3 C405 X2 C315 Fig. 3.2-1: Pin assignments for Terminal X1 X1 Pin no. Function Description ID CPR.M02 1 2 3 4 5 6 7 8 9 10 DAT CLK TxD GND **
RxD
CLS VCC GND **
Data line for the data/clock interface Clock line for the data/clock interface RS232-TTL Transmit Data GND RS232-TTL Receive Data not connected CLS line for the data/clock interface
+ 5 V DC *
GND not connected Use only regulated DC power supplies !
GND-Pins 4 and 9 are to be connected directly to each other
on the Reader Module Table 3.2-1: Pin assignments for Terminal X1 FEIG ELECTRONIC GmbH Page 8 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.2.1. Supply voltage The ID CPR.M02 must be supplied only by a regulated power supply. If switching power supplies are used with the module, be sure that there is adequate filtering. Noise from the power supply can result in a reduction of the read/write range of the module. The cable length from the power supply should be as short as possible, and should in any case not exceed 3 m. X1 Pin no. 8 9, 4 Function VCC *
GND **
Description ID CPR.M02
+ 5 V DC 5%
GND
* Use only regulated power supplies !
** GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.1-1: Pin assignments for X1 NOTE:
Reversing the polarity of the supply voltage may destroy the device. Supply voltages outside the specifications may destroy the device. FEIG ELECTRONIC GmbH Page 9 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.2.2. RS232 interface The length of the cable to the RS232 interface should be kept as short as possible, and must in any case not exceed 3 m. X1 Pin no. 3 4, 9 5 Function TxD *
GND **
RxD *
Description ID CPR.M02 RS232-TTL - Transmit Data GND RS232-TTL - Receive Data
* Signal names as seen by the Reader Module.
** GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.2-1: Pin assignments for the RS232 interface on X1 The transmission parameters for the interface can be software-configured. Table 3.2.2-2 shows the standard parameters for the RS232 interface. Parameter Baud rate No. of data bits Parity No. of stop bits Standard setting 38400 8 Even 1 Table 3.2.2-2: Standard parameters of the RS232 interface. FEIG ELECTRONIC GmbH Page 10 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.2.3. Data/Clock interface The length of the cable to the data/clock interface should be kept as short as possible. It must not exceed 3 m. X1 Pin no. Function Description ID CPR.M02 1 2 7 DAT CLK CLS 4, 9 GND *
Data line for the data/clock in-
terface Clock line for the data/clock interface CLS line for the data/clock in-
terface GND
* GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.3-1: Pin configuration for the RS232 interface on Terminal X1 Host Data Clock CLS GND DAT CLK CLS GND ID CPR.M02 Fig. 3.2.3-1: Connecting the data/clock interface FEIG ELECTRONIC GmbH Page 11 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.2.4. Connection of an external Antenna (ID ISC.ANT19) The ID CPR.M02.VP/AB-CA are intended for the connection of an external 50-Antenna. The use of the integrated antenna is not possible with this version. Fig. 3.2.4-1 and Table 3.2.4-1 shows the pin assignments for Terminal X2 for the connection of the external antenna. The pin connector has a pin spacing of 2.54mm. V2V1 X4 X1 J1 X3 C405 X2 C315 X2 1 2 Signal}
GND Connector ext. Antenna Fig. 3.2.4-1: Pin assignment of Terminal X2 X2 Pin no. 1 2 Function Signal GND Description ID CPR.M02.VP/AB--CA Signal pin of the external 50-Antenna GND pin of the external 50-Antenna Table 3.2.4-1: Pin assignment of Terminal X2 Fig. 3.2.4-2: Ext. 50 antenna ID ISC.ANT19 FEIG ELECTRONIC GmbH Page 12 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.2.5. Optional Module ID SAM.M02 If needed, the optional device ID SAM.M02 can be connected to terminals X3 and X4. The ID SAM.M02 is a module for connecting and driving an additional SAM and provides security by using cryptographic data transmission between the reader and transponder. V1 V2 X4 X1 0
, 0 5 C315 X3 25,0 0
, 0 1 5
, 1 1 Fig. 3.2.4-1: Dimensions of ID CPR.M02 with ID SAM.M02 FEIG ELECTRONIC GmbH Page 13 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.3. Display elements The ID CPR.M02 Reader Module has a green LED (V1) and a red LED (V2) which are used as display elements (Fig. 3.3-1). V1 V2 X4 X1 J1 Fig. 3.3-1: Position of LEDs V1 and V2 LED Color Standard setting V1 V2 Green Flashes 4x after a reset. Flashes continuously at a frequency of 2 Hz. Red Flashes 4x after a reset. Comes on for 1 second after successful communication with a transponder. Table 3.3-1: Standard setting for the LEDs NOTE:
Up from Firmware-Version 1.08 the function of the red LED is connected to X1, Pin7 (CLS). For current limitation an additional resistor with 470 is required. FEIG ELECTRONIC GmbH Page 14 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.4. Operating elements 3.4.1. Operating/Programming Mode: Jumper J1 Jumper J1 is used to configure the operating and programming mode of the ID CPR.M02. In standard operation the jumper is set to Position 1-2 (see Fig. 4.3.1-1). The reader is then in normal operating mode. If the jumper is set to Position 2-3, the integrated hardware bootloader starts after a reset. Since the readers firmware however also has a software bootloader, the hardware bootloader option should be used only if necessary. For additional information about programming the reader, see the corresponding Application Note Firmware Update. Jumper position 1 - 2 2 - 3 Mode Standard setting :
The reader is in normal operating mode. Activation of the hardware bootloader:
After a reset the readers CPU starts its hardware bootloader, which can then be used for new pro-
gramming. Table 3.4.1-1: Jumper J1 J1 3 2 1 Default V2V1 X4 X1 J1 C405 C315 X3 Fig. 3.4.1-1: Jumper J1 FEIG ELECTRONIC GmbH Page 15 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.4.2. Retuning the internal antenna (ID CPR.M02.VP/AB-C) The antenna of the ID CPR.M02.VP/AB-C can be detuned as a result of various ambient condi-
tions such as nearby metal objects (see Section 8.5). This detuning can be compensated to some degree using the trim capacitor C315. V2V1 X4 X1 J1 X3 C405 C315 Trim capacitor C405:
DO NOT CHANGE !!!
Trim capacitor C315:
Retuning the integrated antenna Fig. 3.4.3-1: Trim capacitor for retuning the antenna The integrated antenna can be retuned with the aid of an oscilloscope (bandwidth 20 MHz). To do this, short the GND terminal of the oscilloscope probe with the probe point and hold it over the circuit board of the ID CPR.M02. The probe then forms a measuring loop for the radiated magnetic field of the ID CPR.M02. The distance between the oscilloscope probe and the ID CPR.M02 should be between 0 and 3 cm. Use the software command RF-ON (0x6A) to turn on the HF field of the ID CPR.M02. A 13.56 MHz signal should be visible on the oscilloscope screen. To tune the internal antenna, now set the signal amplitude of the 13.56 MHz signal to maximum using trim capacitor C315. Turn C315 to set amplitude to maximum ID CPR.M02 V1 V2 X1 C65 Fig. 3.4.3-2: Configuration for tuning the internal antenna FEIG ELECTRONIC GmbH Page 16 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 Use caution when the maximum value of the signal amplitude is reached at the minimum or maxi-
mum position of the trim capacitor (Fig. 3.4.3-3). This usually means the antenna is too severely detuned by the surroundings and can no longer be fully compensated by the trim capacitor. Labeling Beschriftung Minimum Minimale Kapazitt capacitance Maximum Maximale Kapazitt capacitance Fig. 3.4.3-3: Minimum and maximum position of the trim capacitor C315 After the antenna has bee tuned, check it again for maximum range and any communication gaps. NOTE:
Notwithstanding the possibility of retuning the antenna as described here, the distance between the reader and the surrounding metal surfaces must be at least 3 cm. Note that even other circuit boards may act like metal objects depending on how much copper they contain. FEIG ELECTRONIC GmbH Page 17 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.5. Installation notes Be aware of the following possible environmental factors when installing an ID CPR.M02 into an-
other device :
Effects from nearby metal objects Detuning of the integrated antenna Impaired propagation of the antennas magnetic field EMC effects on cables Impaired communication between reader and transponder EMC effects from magnetic fields Impaired communication between reader and transponder 3.5.1. Metallic surroundings When installing an ID CPR.M02 into another device, be sure that there are no metal surfaces or objects in the direct vicinity of the reader if possible. These can detune the antenna and thus re-
duce the magnetic field of the integrated antenna. This will in turn result in reduced read distances for the reader. The distance between the reader and a metal surface should be at least 3 cm. Note that even other circuit boards may act line metal objects depending on how much copper they contain. If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping the distance as great as possible. The area between the antenna and transponder as well as the area on the other side of the trans-
ponder should also be kept clear of metal parts. Since any change in the metallic environment will result in detuning of the integrated antenna and therefore to impaired function, no moving metal parts, such as metallic fans, should be allowed in the vicinity of the reader. 3.5.2. EMC effects on cables In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can result in impairment of the communication between the reader and transponder. When installing an ID CPR.M02 into another device, be sure therefore that a clean, noise-free power supply is used. FEIG ELECTRONIC GmbH Page 18 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 3.5.3. EMC effects from magnetic fields Since in this type of RFID-Technology the communication between the reader and transponder takes place by modulation of a magnetic field, alternating magnetic fields in the vicinity of the an-
tenna can have a negative impact on its function. Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. When determining the position of the reader and antenna within a device, check the device for any possible sources of interference as described above. If necessary, use shielding to suppress such interference. FEIG ELECTRONIC GmbH Page 19 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 4. Radio Approvals 4.1. Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. Equipment Classification according ETSI EN 300 330: Class 2 4.2. USA (FCC) FCC ID PJMCPRM02-ANT19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for com-
pliance could void the user's authority to operate the equipment. This device is labeled with an FCC ID number. If this label is not visible when installed in an end device, the outside of the device MUST also display a label referring to the enclosed module. Wording on the label similar to the following shall be used:
This device contains transmitter module FCC ID PJMCPRM02-ANT19 At the time of this printing, the antennas listed below were the only antennas approved for use with the ID CPR.M02 module. Use of other antennas must be approved by FEIG ELECTRONIC GmbH. Antennas approved: ID ISC.ANT19 The FCC sticker is glued at the package. ID CPR.M02/ANT19 FEIG ELECTRONIC FCC ID PJMCPRM02-ANT19 FEIG ELECTRONIC GmbH Page 20 of 20 Manual-M21001-3de-ID-B.doc OBID classic-pro Installation ID CPR.M02/ANT19 5. Technical Data Dimensions ( W x H x D ) Connector Supply voltage Power Consumption Operating Frequency RF Transmitting Power Antenna: ID CPR.M02.VP/AB-CA RS232-TTL Interface:
50 mm x 50 mm x 14 mm 10 pol. Pin-Connector (grid dim. 2,54 mm) 5 V DC 5% ripple 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp max. 1,5 W 13.56 MHz 250 mW 2 dB External (separate 2 pol. Pin-Connector) ID CPR.M02.VP/AB-C / -CA 4.800 to 230.400 Baud Daten-/Takt Interface EEPROM (for parameters) FLASH Supported Transponders read and write Security Function (optional) Optical Indicators Temperature Range Radio Approval EMC Safety Operating Storage Europe USA Magnet Stripe Emulation Wiegand Emulation 1 kB
(10,000 write cycles) 64 kB (software update on interface possible) ISO14443-A compatible
(e. g. mifare, mifare Ultra Light, my-d proximity) ISO14443-B compatible ISO15693 compatible
(e. g. ICode SLI, Tag-It HFI, my-d vicinity, STM LRI512) ICode 1 (optional) SAM (Security Access Module), e.g. for my-d vicinity and my-d proximity LED green: running;
LED red: Transponder detected
-20C to +70C
-40C to +85C EN 300 330 FCC 47 CFR Part 15 EN 301 489 EN 60950 FEIG ELECTRONIC GmbH Page 21 of 20 Manual-M21001-3de-ID-B.doc