INSTALLATION ID CPRPOS Card reader for contactless and contact smart cards final public (B) 2015-07-27 ID CPRPOS User Manual-01.doc Installation Note ID CPRPOS OBID classic-pro Copyright 2015 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID myAXXESS is a registered trademark of FEIG ELECTRONIC GmbH. All brand names, trademarks or logos are property of their respective owners. FEIG ELECTRONIC GmbH Page 2 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro Installation Contents 1. Safety Instructions / Warning - Read before start-up !
2. Characteristics of the ID CPRPOS ID CPRPOS 4 5 2.1. Scope of delivery ............................................................................................................... 5 2.2. Available accessories and spare parts ............................................................................ 6 3. Dimensions 4. Connections 7 8 4.1. Ethernet interface .............................................................................................................. 9 4.2. USB interface ................................................................................................................... 10 4.3. RS232 interface / Power supply ...................................................................................... 11 5. Display and LED 12 5.1. Display ............................................................................................................................. 12 5.2. LED ................................................................................................................................... 13 6. Installation of a Secure Access Module (SAM) 7. Radio Approvals 14 15 7.1. Europe (CE) ...................................................................................................................... 15 7.2. USA (FCC) and Canada (IC) ............................................................................................ 15 8. Technical Data 17 FEIG ELECTRONIC GmbH Page 3 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro Installation ID CPRPOS 1. Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in an immediate proximity of the device respective the antenna for some time. FEIG ELECTRONIC GmbH Page 4 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro Installation ID CPRPOS 2. Characteristics of the ID CPRPOS The ID CPRPOS is a smart card reader for contactless and contact smart cards according to ISO 14443-A/B and ISO 7816. The reader is designed as desktop device and is due to the support of different chip types like mifare classic, mifare DESFire and mifare PLUS suitable for a wide range of applications. In addition to the contact based smart card interface for ID-1 sized smart cards the ID CPRPOS has one SAM socket for ID-000 sized smart cards available. The ID CPRPOS can be connected and controlled by a host system via its RS232, USB or Ether-
net interface. A connected host system is able to use the ID CPRPOS to communicate with smart cards and to control the user guidance via display, LED and buzzer. The reader could be config-
ured by the connected host system, too. contactless smart card interface display contact smart card interface Figure 1: Surface of the ID CPRPOS 2.1. Scope of delivery The scope of delivery includes following components:
1 x Electronic unit ID CPRPOS 1 x Power supply unit 1 x USB connection cable 1 x Wire strap FEIG ELECTRONIC GmbH Page 5 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro Installation ID CPRPOS 2.2. Available accessories and spare parts Table 1: Available accessories and spare parts Order Number Article Description 4219.000.00 OBID myAXXESS ID NET.5V-EU Power supply unit (5 V DC / 1 A); Length of the connection cable: 1,5 m RS232 connection cable incl. connector for power supply
- Host connector: D-SUB 9 poles 4218.000.00 ID CAB.RS-C
- Device connector: RJ-12 plug 6 poles
- Power supply connector: RJ-12 jack 6 poles
- Length: 2,0 m FEIG ELECTRONIC GmbH Page 6 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro 3. Dimensions Installation ID CPRPOS The ID CPRPOS is designed as desktop device. Its small form factor offers the possibility to place the reader directly on a sales counter or at a cashier station. Due to its rubber feet the reader is suitable for slippery undergrounds. Figure 2: Top view Figure 3: Side view FEIG ELECTRONIC GmbH Page 7 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro 4. Connections Installation ID CPRPOS Figure 4: ID CPRPOS - position of the connectors Ethernet interface (RJ-45) USB interface (Mini-USB) NOTE:
Only one host interface should be used at the same time. The usage of more than one host interface at the same time can cause malfunctions. RS232 interface and power supply (RJ-12) FEIG ELECTRONIC GmbH Page 8 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro 4.1. Ethernet interface Installation ID CPRPOS The ID CPRPOS has an integrated 10/100 base-T network port with a common RJ-45 connector and an automatic crossover correction. With structured cabling CAT5 cables should be used. This ensures a reliable operation at 10 Mbps and 100 Mbps. The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All readers have a factory set IP address. The communication parameter could be configured user-defined. Table 2: Standard factory configuration of the ethernet interface Network IP address Subnet mask Port DHCP Address 192.168.10.10 255.255.0.0 10001 OFF NOTE:
The reader is equipped with a DHCP ready ethernet interface. It is recommended to use a screened STP (shielded twisted pair) CAT5 cable. FEIG ELECTRONIC GmbH Page 9 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro 4.2. USB interface Installation ID CPRPOS The ID CPRPOS is equipped with a USB on-the-go interface (USB mini jack). It allows a direct connection to a host system for controlling, configuration and firmware update of the device (ID CPRPOS is USB slave). In addition the ID CPRPOS offers the possibility to connect an external USB memory stick to the electronic unit by means of a USB on-the-go adaptor (ID CPRPOS is USB master). Figure 5: USB mini jack Figure 6: USB mini cable for host connection With the delivered wire strap the USB cable could be fixed at the housing and a strain relief for the cable connection could be established. NOTE:
The device needs a separate power supply via the RJ-12 jack. A power supply of the device via the USB interface is not supported. FEIG ELECTRONIC GmbH Page 10 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro Installation ID CPRPOS 4.3. RS232 interface / Power supply 6 1 Figure 7: Pin assignment RJ-12 jack Table 3: Pin assignment RJ-12 jack Pin No. 1 2 3 4 5 6 Name Vcc RS232-RxD RS232-TxD nc nc GND Function 5 V DC, approx. 500 mA RS232 interface not connected not connected Ground By using USB or Ethernet as communication interface the power supply unit included could be directly connected to the RJ-12 jack of the device. For usage of the RS232 interface a special RS232 connection cable is available (see 2.2. Available accessories and spare parts). In that case the included power supply unit has to be connected to the RJ-12 jack of the connection cable. The RJ-12 plug of the connection cable has to be connect-
ed to the RJ-12 jack of the device. CAUTION:
The device has to be supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-
ply) according IEC EN 60950, only!
Reversing the polarity of the supply voltage may destroy the device. FEIG ELECTRONIC GmbH Page 11 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro 5. Display and LED Installation ID CPRPOS display LED Figure 8: Display and LED The ID CPRPOS is equipped with a display as well as LED for user guidance and to show status information. 5.1. Display A connected host system can send text messages via the interfaces RS232, USB, and Ethernet to the integrated graphic display to realise a user guidance. Customised graphics (monochrome Bit-
maps with size 128 x 64 dots; e.g. company logo or advertisement) could be stored in the device and could be shown outside the user guidance. For further information please read the system manual H31010-xx-ID-B.pdf. Note:
With temperatures below -10 C the display contents could be shown slower. FEIG ELECTRONIC GmbH Page 12 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro 5.2. LED Installation ID CPRPOS The three LEDs of the ID CPRPOS indicate the status of the device for the user. The device is equipped with 1 green, 1 yellow, and 1 red LED. Figure 9: Position of the LED on the ID CPRPOS Table 4: LED on the ID CPRPOS LED green red yellow Description Communication with a contactless smart card Error
-
In table 4 the meaning of the LEDs with standard configuration is described. The LED could be controlled by a connected host system and a customized LED indication is possible. FEIG ELECTRONIC GmbH Page 13 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro Installation ID CPRPOS 6. Installation of a Secure Access Module (SAM) To install a secure access module (SAM) the bottom part of the housing has to be opened. After removing the 4 screws the bottom part of the housing could be opened. Figure 10: Opening of the housing A socket is located on the PCB in which the SAM can be plugged in. To open the socket the cover of the socket has to be pushed slightly in direction OPEN. Afterwards it can be lifted. The SAM has to be inserted according Figure 11: Installation of a SAM. The golden contacts of the chips are facing towards the PCB when the socket is closed. After the socket is closed it has to be locked again by pushing it slightly towards in direction CLOSE. Afterwards the housing could be closed and the screws could be replaced. Figure 11: Installation of a SAM NOTE:
The maximum tightening torque of the housing screws is 0,30 Nm. FEIG ELECTRONIC GmbH Page 14 of 18 ID CPRPOS User Manual-01.doc Installation ID CPRPOS OBID classic-pro 7. Radio Approvals 7.1. Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/EC dated March 99. Equipment Classification according ETSI EN 300 330: Class 2 7.2. USA (FCC) and Canada (IC) Product name:
FCC ID:
IC:
Notice for USA and Canada ID CPRPOS PJMCPRPOS 6633A-CPRPOS This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux condi-
tions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, m-
me si le brouillage est susceptible d'en compromettre le fonctionnement. FEIG ELECTRONIC GmbH Page 15 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro Installation ID CPRPOS Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. Installation with FCC / IC Approval:
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada. FEIG ELECTRONIC GmbH Page 16 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro 8.Technical Data Table 5: Technical Data Housing Dimensions Weight Protection class Temperature range Relative air humidity Supply voltage Current consumption Contactless smart card interface Operating frequency Antenna Installation ID CPRPOS ID CPRPOS plastic 92 mm x 161 mm x 58 mm approx. 250 g IP20 operation storage
-20 C up to +70 C (-4 F up to +158 F)
-30 C up to +80 C (-22 F up to +176 F) max. 95 %
+5 V DC 5 %
approx. 500 mA tested according to EMVCo Contactless Level 1 13,56 MHz internal Supported transponder types (contactless)
(Read and Write) Contact smart card interface ID-1 ID-000 Interfaces USB RS232 Ethernet Optical indicator Acoustic indicator Flash memory ISO/IEC 14443-4, NFC card emulation mode Type 1, 2, 4, mifare classic, mifare PLUS, mifare DESFire, mifare ultralight, my-d move, my-d prox-
imity, SR176, SRIx, Calypso (Innovatron radio protocol) tested according to EMVCo Contact Level 1;
landing contacts; 200 000 cycles SAM socket; ISO 7816; 9600 up to 625.000 Bit/s T=0 and T=1 protocol Power Class A, B, C Mini-USB-Jack; Self powered device 4.800 - 921.600 Baud; RJ-12-Jack 10BASE-T/100BASE-TX; MDI/MDI-X cross over detection; IPv4 1 x LED red; 1 x LED yellow; 1 x LED green graphic LCD, 128 x 64 dots 1 internal buzzer 2 MByte write cycles 100.000 FEIG ELECTRONIC GmbH Page 17 of 18 ID CPRPOS User Manual-01.doc OBID classic-pro Installation ID CPRPOS Radio Approval EMC Environmental (shock, vibration, climate) Health and Safety Waste and Hazardous Substances Europe EN 300 330 USA FCC 47 CFR Part 15 Canada IC RSS-Gen, RSS-210 EN 301 489 IEC 60068 EN 60950 EN 50364 WEEE - 2002/96/EC RoHS - 2011/65/EC Function tested according to EMVCo Contactless/Contact Level 1 FEIG ELECTRONIC GmbH Page 18 of 18 ID CPRPOS User Manual-01.doc