INSTALLATION ID CPR60 RFID Reader Module Modell ID CPR60-A Artikel Nr. 5491.000.00 draft public (B) 2020-04-27 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 Note Copyright by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. All brand names, trademarks or logos are property of their respective owners. FEIG ELECTRONIC GmbH Page 2 of 16 CPR60_Installation M91210-0e_03.doc
IDENTIFICATION ID CPR60 Installation Content 1. Safety Instructions / Warning - Read before start-up !
2. Characterization ID CPR60 2.1. Available Accessories ....................................................................................................... 5 2.2. Available Software Tools, USB Driver and Firmware ...................................................... 6 3. Dimensions 4. Installation and wiring 6. Technical Data 7. Approvals 4.1. Connector X1 ..................................................................................................................... 8 4.2. Connector ANT ................................................................................................................ 10 5. Standby / Low Power Card Detection 7.1. Europa (CE) ...................................................................................................................... 14 7.2. USA (FCC) and Canada (IC) ............................................................................................ 15 4 5 7 8 11 12 14 FEIG ELECTRONIC GmbH Page 3 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 1. Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorised changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorised measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. The reader module is a limited module. The HF Reader IC has no internal shielding. The module is designed for installation in electronic devices. (e.g. printers, terminals, hand scanners, etc.) Care must be taken to ensure that no switching power supply, oscillator or high current lines are routed directly along the module. Or located under the module. Only the antennas, mentioned in the manual, may be used. The cable length to the an-
tenna is limited to 1m. Take care that the PCB design in the host environmentis is EMC compliant. Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the external antenna and your cardi-
ac pacemaker and not stay in an immediate proximity of the device respective the an-
tenna for some time. FEIG ELECTRONIC GmbH Page 4 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 2. Characterization ID CPR60 The ID CPR60 is a RFID reader which supports ISO/IEC 14443 A/B and ISO 15693 contactless smart cards and transponders. It also offers 4 interfaces to connect ISO 7816 smart cards with contacts. Three different antennas, can be connected can be connected to the 50 Ohm antenna output. The antennas have different dimensions: Antenna No. 1 ID ISC.ANT100/100 with 100x100mm, Anten-
na No. 2 ID ISC.ANT40/30 and Antenna No. 3 RFID Antenna Board 445-100302 with 30x30mm. Optional the RFID interface can support the contactless standards ISO18000-1 mode 3, NFC P2P passive initiator mode in accordance with ISO/IEC 18092 and JIS X 6319-4 (comparable with FeliCa). This support is available on request only. For host communication ID CPR60 offers an USB device full speed interface, a RS232-LVTTL in-
ter-face (COM Interface) and a SPI interface. For data transfer with a host computer the ISO-host mode (polling) is available via the USB, COM and SPI interface. The functionality of the ID CPR60 is based on the well known ID CPR-family, like the reader mod-
ule ID CPR74 or the wall-mount reader ID CPR50.10 and is compatible with them mainly. The use of ISO-host commands guarantees an easy creation of user software as well as the com-
patibility with all other FEIG RFID readers. Beside the CPRStart software for demonstration and configuration of the reader capabilities and the Firmware Update Tool a lot of different Software Development Kits (SDK) and drivers are available to support an easy integration into the customer's application. 2.1. Available Accessories Tab. 1 Available Accessories and spare parts Part Number Part name Description 5604.000.00 ID CPR60-DevBoard 3674.000.00 ID ISC.ANT40/30-U.FL-A 3673.000.00 ID ISC.ANT100/100-U.FL-A 3540.000.00 RFID Antenna Board 445-100302 Development Board for the ID CPR60 incl. Power Supply with European plug 50 Ohm Antenna with U.FL-connector for the connection to the ID CPR60 Dimensions: 40 mm x 30 mm 50 Ohm Antenna with U.FL-connector for the connection to the ID CPR60 Dimensions: 100 mm x 100 mm 50 Ohm Antenna with U.FL-connector for the connection to the ID CPR60 Dimensions: 30 mm x 30 mm FEIG ELECTRONIC GmbH Page 5 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 2.2. Available Software Tools, USB Driver and Firmware The USB driver and the test and configuration tool CPRStart are available on our FEIG download area:
For firmware updates we are providing the FirmwareUpdateTool and a external firmware xml-file. For demonstration and development purposes a special PCB with connectors, SAM sockets and power supply is available on request. https://www.feig.de/en/login/
Username: feig_ Customer Password :
2.3. Development Board Description of the Demo Board:
FEIG ELECTRONIC GmbH Page 6 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 3. Dimensions The ID CPR60 reader module has been designed for the integration into terminals, printers or handheld devices and so on. Figure 1: Dimension (Top View) Figure 2: Dimension (Side View) FEIG ELECTRONIC GmbH Page 7 of 16 CPR60_Installation M91210-0e_03.doc Installation ID CPR60 X1 (Connector Type: Hirose DF17(2.5)-80DP-0.5V(57)) is the main connector for power supply, interfaces and control signals. The following table shows the pin-assignment of the connector. In-
terfaces and functions are described from the ID CPR60 view (an input must be connected to one output or vice versa). Figure 3: Connector X1 At connector X1 four external smart card connectors can be connected. SAM1, SAM2, SAM3 and KCC whereas only KCC supports a card presence signal, which also can used to awake the CPR60 form standby mode (see: 5. Standby / Low Power Card Detection). PIN Function Remark PIN Function Remark IDENTIFICATION 4. Installation and wiring 4.1. Connector X1 X1 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 n.c. n.c. n.c. n.c. GND 3,3 V DC Supply 3,3 V DC Supply SAM3_ CLK KCC_CLK (SAM4) SAM1_I/O SAM2_I/O SAM3_I/O KCC_I/O (SAM4) n.c. n.c. 3,3 V DC Supply n.c. n.c. n.c. n.c. GND GND n.c. n.c. n.c. n.c. n.c. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 SAM1_VCC SAM2_VCC SAM3_VCC FEIG ELECTRONIC GmbH Page 8 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 PIN Function Remark PIN Function Remark n.c. n.c. GND n.c. SAM1_ RST SAM2_ RST SPI_MISO*
CPR60 is Slave SPI_MOSI*
CPR60 is Slave SPI_nCS**
CPR60 Input SPI_CLK**
CPR60 Input GND KCC_VCC (SAM 4) SAM1_CLK SAM2_CLK USB DP*
USB DM*
n.c. n.c. n.c. 51 SAM3_RST 52 nLOW_PWR nKCC_DET (SAM 4) Smartcard present con-
nector input 0: Card preset 1: Card no present Control input for low power card detection 0: low power mod low 1: normal mode RS232_TxD reader TxD, host RxD RS232_RxD*
Reader RxD, Host TxD nRESET Reset Input IRQ output with double function:
SPI-IRQ Low power card detection: Card de-
tected 32 34 36 38 40 42 44 46 48 50 54 56 58 60 62 64 66 68 70 72 74 76 78 80 n.c. n.c. GND n.c. 5 V DC Supply n.c. n.c. SPI_INT n.c. GND n.c. n.c. 31 33 35 37 39 41 43 45 47 49 53 55 57 59 61 63 65 67 69 71 73 75 77 79 KCC_RST (SAM 4) GND n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. GND n.c. n.c.
* 5 V tolerant Input
** 3,3 V tolerant Input FEIG ELECTRONIC GmbH Page 9 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 4.2. Connector ANT The ID CPR60 module is equipped with an connector for an external 50 W The connection of the external antenna is possible via the U.FL connector ANT.
-antenna. ANT:
(U.FL) Figure 4: Connection of an external antenna NOTICE:
1. Three different antennas can be connected. The antennas have different dimensions. Antenne 1 (100 x 100mm) Antenne 2 (40 x 30mm) Antenne 3 (30 x 30mm) ID ISC.ANT100/100 ID ISC.ANT40/30 RFID Antenna Board 445-100302 2. The antenna output is neither permanent short circuit protected nor permanent no-load protected. 3. A coaxial cable, U.FL-LP-088, is used to connect the antenna. The antenna cable should be no longer than 1m. The use of other cable length are possible after consulting the manufacturer. FEIG ELECTRONIC GmbH Page 10 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 5. Standby / Low Power Card Detection The ID CPR60 offers a standby mode to reduce the power consumption to a minimum. The standby mode can be controlled by the host via input nLOW_PWR (see: 4.1. Connector X1). The standby mode is activated if input nLOW_PWR is set to low. In this mode the reader wakes up if:
- a contactless card is detected in front of the RFID antenna or
if the Input nKCC_DET is set to 0 The reader remains active for a configurable time. Even if nLOW_PWR is set to high during this time the reader remains active as long as nLOW_PWR is set to high. The host can switch the reader at any time back into the standby mode with command [0x64] Sys-
tem Reset. FEIG ELECTRONIC GmbH Page 11 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION 6. Technical Data Tab. 2: Technical data Dimension (W x H x D) Weight Temperature Range 1 Power Supply Current Consumption USB SPI RS232-LVTTL Interfaces Driver RFID Interface Operating Frequency Output Power Antenna Connection Contact Interface (ISO 7816) Installation ID CPR60 max. 41 mm x 41 mm x 6,5 mm ID CPR60 approx. 10 g Operating Storage
-25 C up to +70 C (-13 F up to +158 F)
-40 C up to +85 C (-40 F up to +185 F) Humidity max. 95 % (not condensing) for digital circuit:
3,3 V DC 5 %
max power consumption: 100 mA for analog circuit:
5 V DC 5 %
Ripple: 0...250 kHz < 10 mVpp up from 250 kHz < 0,1 mVpp max power consumption peak (excl. SAM): 300 mA typ. power consumption with RFID (excl. SAM): 200 mA
< 500 mA (without SAM)
< 25mA Standby mode
< 50mA Standby Mode with Wake-Up-by-Card Full-Speed (12 Mbit/s), Self-Powered Device Slave Device (up to 16 Mbit/s) 4 800 921 600 Baud USB Driver, PC/SC-Driver (WHQL) Windows 7, 8 and 10 32/64 Bit Windows Server 2012 and 2016 ISO/IEC 14443-A/-B
(ISO-Mode: 106, 212, 424, 847 kbit/s;
EMVCo Mode: 106 kBit/s) ISO 15693 13,56 MHz typ. 450 mW U.FL-Socket 4 SAM card interfaces T=0 and T=1 Protocol, Power Class A, B & C Connector (Vcc, USB , SPI, Smart Card) 80 pol. (see: 4.1. Connector X1) Software Development Kits Windows, Windows CE and Linux (C++, .NET, JAVA) Operating Modes ISOHost Mode (Polling Mode) 1 The device has to be supplied by a limited power supply according IEC EN 60950-1 chap-
ter 2.5, only. FEIG ELECTRONIC GmbH Page 12 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 Europe USA Canada Radio Approval EMV Safety and Health Waste and Hazardous Substances EN 300 330 Available on request Available on request EN 301 489 EN 60950 EN 50364 WEEE - 2002/96/EC RoHS - 2011/65/EC FEIG ELECTRONIC GmbH Page 13 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 7. Approvals 7.1. Europa (CE) Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID CPR60 is in com-
pliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
http://www.feig.de/en/downloads-support/declarations-of-conformity.html Performance Classification according to ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Page 14 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 7.2. USA (FCC) and Canada (IC) Product name:
FCC ID:
IC:
Notice for USA and Canada ID CPR60 PJMCPR60 6633A-CPR60 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux condi-
tions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. Installation with FCC / IC Approval:
The reader module was tested according to the standard FCC - Title 47 CFR Part 15 207, $209 and 225 and the ISED standard RSS 210 Issue 10 and RSS Gen Issue 5 . The module is con-
form to the listed limits in the standards. In normal operation the RF exposure is far below the limits of OET Bulletin 65. This module is approved for installation into fixed and/or mobile host platforms and must not be co-
located or operating in conjunction with any other antenna or transmitter except in accordance with FCC/ISED multi-transmitter guidelines. End users must be provided with transmitter operating conditions for satisfying RF Exposure compliance. The manufacturer is obliged to include a notice "Contains FCC ID: PJMCPR60 an IC: 6633A-
CPR60" at the user manual and on the product label. FEIG ELECTRONIC GmbH Page 15 of 16 CPR60_Installation M91210-0e_03.doc IDENTIFICATION Installation ID CPR60 The manufacturer is obliged to test the terminal device together with the reader module according to the national FCC requirements according to 47 CFR Part15 209 and 225 For this purpose the reader module must be set to normal operation, ScanMode. The Scan mode is switched with on by SW command: Transparent Command - ISO 14443A [ReqA] HEX: 02 00 0A FF 00 30 02 01 The manufacturer is obliged to test the terminal device together with the reader module according to the national FCC requirements according to 47 CFR Part15 209 and 225 For this purpose the reader module must be set to normal operation, ScanMode. The Scan mode is switched with on by SW command: Transparent Command - ISO 14443A [ReqA] HEX: 02 00 0A FF 00 30 02 01 The manufacturer is obliged to test the terminal equipment without RF transmitter, according to the national FCC requirements according to 47 CFR Part 15 Subpart B. For this purpose, the HF transmitter of the reader module must be switched off. The HF transmitter is switched off by the SW command: Transparent Command - HF Off HEX: 02 00 0A FF 00 04 01 00 FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada. FEIG ELECTRONIC GmbH Page 16 of 16 CPR60_Installation M91210-0e_03.doc