all | frequencies |
|
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|---|
manuals | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
- Installation Manual | Users Manual | 981.68 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
PAD74-U - Installation Manual | Users Manual | 670.01 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
UserManual | Users Manual | 520.33 KiB | ||||
1 2 |
|
Internal Photos | Internal Photos | 690.47 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
External Photos | External Photos | 683.67 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
ID Label/Location Info | ID Label/Location Info | 323.56 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
Annex no.11 Antenna requirements | Test Report | 408.06 KiB | December 19 2023 / January 04 2024 | |||
1 2 | Annex. 07 - - Blockdiagram | Block Diagram | December 19 2023 | confidential | ||||
1 2 | Annex. 08 - - Operational Description | Operational Description | December 19 2023 | confidential | ||||
1 2 | Annex. 09 - - Shematic | Schematics | December 19 2023 | confidential | ||||
1 2 | Annex. 09 - PAD74-U PAD240180-B - Shematic | Schematics | December 19 2023 | confidential | ||||
1 2 | Annex. 10 - - BOM - Parts Component List | Parts List/Tune Up Info | December 19 2023 | confidential | ||||
1 2 | Annex. 10 - PAD74-U PAD240180-B - BOM | Parts List/Tune Up Info | December 19 2023 | confidential | ||||
1 2 |
|
Attestation Statements | Attestation Statements | 125.61 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
Class II permissive change letter | Cover Letter(s) | 25.00 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
Confidentiality | Cover Letter(s) | 68.04 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
Declaration of authorization | Cover Letter(s) | 196.83 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
Declaration of authorization use of TCF | Cover Letter(s) | 246.05 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
Equality Declaration | Cover Letter(s) | 115.50 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
RF Exposure Info | RF Exposure Info | 455.21 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
Test Report | Test Report | 1.17 MiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
Test Setup Photos | Test Setup Photos | 506.11 KiB | December 19 2023 / January 04 2024 | |||
1 2 |
|
US agent | Attestation Statements | 65.67 KiB | December 19 2023 / January 04 2024 | |||
1 2 | Cover Letter(s) | |||||||
1 2 | External Photos | |||||||
1 2 | Internal Photos | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | Test Report | |||||||
1 2 | Test Setup Photos |
1 2 | - Installation Manual | Users Manual | 981.68 KiB | December 19 2023 / January 04 2024 |
IDENTIFICATION
=== Ende der Liste fr T extm arke Deckbl att ===
INSTALLATION MANUAL ID CPR74 RFID Reader Module Model Article-No. ID CPR74-4SCUSB 4607.000.00 ID CPR74-CUSB 4606.000.00 M60610-5e-ID-B IDENTIFICATION CPR74 Note Note Copyright by FEIG ELECTRONIC GmbH Industriestrae 1a D-35781 Weilburg (Germany) Tel.: +49 6471 3109-0 https://www.feig.de/en/
identification-support@feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guarantee for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. Page 2 of 21 IDENTIFICATION CPR74 Content Contents 1 2 2.1 2.2 2.3 3 4 4.1 4.2 4.3 4.4 5 5.1 5.2 6 7 Safety Instructions Characterization ID CPR74 4 5 Scope of delivery ............................................................................................................... 6 Available Accessories ....................................................................................................... 6 Available Software Tools, USB Driver and Firmware ...................................................... 6 Dimensions Installation and wiring 7 8 Connector X1, X2 ............................................................................................................... 8 Digital Outputs ................................................................................................................. 10 Connection of an external Antenna ................................................................................ 11 SAM Slots ......................................................................................................................... 12 4.4.1 Installation of a SAM Card in a SAM Socket ......................................................... 13 Power supply 14 Power via USB Interface ................................................................................................. 14 Standby- / Wake-up-by-Card-Mode ................................................................................ 14 Indicators / LEDs Installation notes 15 16 7.1 Metallic surroundings ..................................................................................................... 16 7.2 7.3 8 9 9.1 9.2 EMC effects on cables ..................................................................................................... 16 EMC effects from magnetic fields .................................................................................. 17 Technical Data Radio Approvals 18 20 Declaration of Conformity (CE), (UKCA), (PJMCPR40), (6633A-CPR40) ...................... 20 USA (FCC) and Canada (IC) ............................................................................................ 20 Page 3 of 21 IDENTIFICATION CPR74
=== Ende der Liste fr T extm arke Note ===
1 Safety Instructions The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes. When working on devices the valid safety regulations must be observed. Before touching the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. The fading of an operation control (LED) is no indicator for an interrupted power supply or the device being out of voltage!
Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in the immediate proximity of the devices antenna for any length of time. Page 4 of 21 IDENTIFICATION CPR74 2 Characterization ID CPR74 The reader modules ID CPR74 are designed for data exchange (read and write) with passive transponder according ISO14443 type A and type B, ISO15693, ISO18000-3M3 and are capable for communication with NFC devices (ISO18092). The small dimensions and the different available interfaces (RS232-TTL or USB) make it suitable for an easy integration into terminals, housings and other devices. The following different types of reader modules are available:
Dimensions L x B x H 50 mm x 68 mm x 10 mm 50 mm x 68 mm x 8 mm ID CPR74-4SCUSB ID CPR74-CUSB 5 V DC 5 %
internal external 4
Power supply Antenna:
SAM Socket Digital outputs Interface RS232-TTL USB full-speed (12Mbit/s) 3 The variant ID CPR74-4SCUSB is equipped with 4 sockets for Security Access Modules (SAM) in the ID000 format. Because of the SAM current consumption the reader module is designed as Self-Powered-Device and need a separate power supply. The voltage supply from a USB port is not sufficient in this case. Because of their high performance and a wide range of different configuration parameters the reader modules ID CPR74 is suitable for a lot of applications like eTicketing, ePayment, eDocument, eMobility and medical devices. With the help of the integrated antenna multiplexer an external antenna can be used additional to the internal antenna. In Scan Mode the reader can switch between both antenna automatically. The implemented SoftCrypto and SAMCrypto high level functions offer a comfortable and fast interface for the access to the encrypted data of an mifare Desfire, mifare Plus or mifare Ultralight transponder. The reader module with a corresponding external antenna is ready for a EMVCo Contactless Level 1 certification as well as a VDV-KA certification (corresponding to BSI TR-03105 Part 4) or in the future CEN/TS 16794 approval. The certification suitability need to be evaluate for each individual case because of the used external antenna and the installation situation. The SAM Sockets have been approved according the EMVCo Contact Level 1 and they are eligible for the certification. Page 5 of 21 IDENTIFICATION CPR74 2.1 Scope of delivery The delivery contains the following parts:
1 x RFID Reader module ID CPR74 2.2 Available Accessories Tab. 1 Available Accessories and spare parts Part Number Part name Description 3674.000.00 ID ISC.ANT40/30-U.FL-A 3673.000.00 ID ISC.ANT100/100-U.FL-A 3540.000.00 ID ISC.ANT.C05-A 3541.000.00 ID CAB.USB-B 50 Ohm Antennae with U.FL-connector for the connection on the ID CPR74 Dimensions: 40 mm x 30 mm 50 Ohm Antennae with U.FL-connector for the connection on the ID CPR74 Dimensions: 100 mm x 100 mm 50 Ohm Antenna cable with U.FL connector on both sides for the connection of an external antenna on the ID CPR74 Dimension : 500 mm; Color: black USB-cable for the connection of the ID CPR74 on an external host Dimension: 2,75 m 2.3 Available Software Tools, USB Driver and Firmware The USB driver and the test and configuration tool CPRStart and in future ISOStart+ are available on our Feig download area:
https://www.feig.de/en/login/
Username: CPR74 Password : FE900 For firmware updates we are providing a Firmware Update Tool and a external firmware xml-file. Page 6 of 21 IDENTIFICATION CPR74 3 Dimensions The ID CPR74 reader module has been designed for the integration into terminals, printers or handheld devices and so on. Figure 1: Dimension (Top View) Figure 2: Dimension (Side View) Page 7 of 21 IDENTIFICATION CPR74 4 Installation and wiring 4.1 Connector X1, X2 The reader can be connected to a RS232-TTL interface and the power supply by using the multi-pin connector X1. The multi-pin connector X2 provide the connection for the USB interface. The device with SAM Sockets is a self-powered USB device which requires a separate power supply. The following figure 4 and the table shows the assignment of the pins X1 (7pol.) and X2 (5pol.) Typ JST PH RM 2 mm (horizontal). X2 X1 1 5 1 7 Figure 3: Plug JST PH Figure 4: ID CPR74 - plug and connections Page 8 of 21 IDENTIFICATION CPR74 Tab. 2 Assignment of the pins on X1 and X2 X1 Pin-No. Symbol ID CPR74 1 2 3 4 5 6 7 X2 Pin-No. 1 2 3 4 5 OUT1 OUT2 OUT3 GND*
RxD TxD Digital Output 1 Digital Output 2 Digital Output 3 RS232-TTL RS232-TTL VCC**
+ 5 V DC 5 %
Shielding USB-Cable Shielding GND*
USB-D PLUS USB-D MINUS VCC**
+ 5 V DC 5 %
* GND are connected internal directly
** VCC are connected internal directly. Feed-In VCC only at one pin! This is especially important if the reader is connected to a USB port. Please take care!
Page 9 of 21 IDENTIFICATION CPR74 NOTICE:
Only one host interface can be used at the same time. Using several host interfaces at the same time can force malfunctions. The reader has to be supplied by a limited power supply according to EN 62368-1 PS1, only!
Use only regulated power supplys. The connection cable (RS232TTL, USB, VCC) should be as short as possible and must be shorter than 3 m to reduce the influence of noise. Reversing the polarity of the supply voltage may destroy the device. Supply voltages outside the specifications may destroy the device. If switching power supplies are used with the module, be sure that there is adequate filtering. Noise from the power supply can result in a reduction of the read/write range of the module. 4.2 Digital Outputs The Figure 5 shows the circuit diagram of the digital outputs OUT1 OUT3. The digital outputs are intended for the connection of external LEDs. Figure 5: Wiring of digital outputs OUT1...3 Page 10 of 21 IDENTIFICATION CPR74 4.3 Connection of an external Antenna The ID CPR74 modules are equipped with an internal 50 -antenna and have an additionally connector for an external 50 -antenna. In Scan mode it is possible to switch between the two antennas automatically. In the ISOHost Mode the switching of the antenna can be performed by commands. The use of the external antenna is configurable in the reader settings. The connection of the external antenna is possible via the U.FL connector ANT. Optional it is possible to integrate a 2-pin SMD connector (spacing 2,54 mm) on position X6. X6:
Optionale 2 pol. SMD Stiftleiste ANT:
(U.FL) Figure 6: Connection of an external antenna The technical description and hints for building external 50 -antennas can be taken from the application note N20901-#d-ID-B.pdf. Name Description ANT Subminiature Coaxial connector for an external 50 -antenna X6 Optional 2pin. connector for an external 50 -antenna NOTICE:
Only for use with 50 matched external antennas. The permanent usage of unmatched antennas can damage the reader electronic. The antenna output is neither permanent short circuit protected nor permanent no-load protected. The antenna cable should be no longer than 1m. The use of other cable length are possible after consulting the manufacturer. Page 11 of 21 IDENTIFICATION CPR74 4.4 SAM Slots Figure 7 shows the position of the 4 SAM slots (S1-4). Each SAM slot is designed for a ID000 formatted SAM Card. NOTICE Wrong inserted SAM cards and forcefully opening or closing can damage the SAM slot. See chapter: Installation of a SAM Card in a SAM Figure 7: Position of the 4 SAM Sockets Page 12 of 21 IDENTIFICATION CPR74 4.4.1 Installation of a SAM Card in a SAM Socket The following step by step instruction shows the installation of a SAM Card into the SAM socket S1. 1. Closed SAM socket without SAM card. 2. Push the latch to the right side and open the cover carefully. 3. Put the SAM card into the cover. The contact plate face up and the beveled corner outside 4. The SAM card must be pushed up against the stop angle. 5. The SAM card must not be inserted with the beveled corner first. 6. Close the top cover with carefully pressure to snap into place. Push the latch to the left side. Page 13 of 21 IDENTIFICATION CPR74 5 Power supply The reader ID CPR74-SCUSB with 4 SAM slots is designed as a Self-Powered USB Device and needs an additional 5 V DC power supply. The power supply must meet the following specification:
+5 V DC 5 %
Ripple:
0...250 kHz < 10 mVpp from 250 kHz < 0,1 mVpp Note:
On both device variants you need to take care that the voltage supply of the USB port is not connected in the case if an external power supply is connected. 5.1 Power via USB Interface The reader ID CPR74-CUSB (without SAM-Sockets) can be optional powered via a High Powered USB port
(500mA). 5.2 Standby- / Wake-up-by-Card-Mode The Standby mode or the Wake-up-by-Card function can be configured in the reader configuration. See system manual H60410-xe-ID-B.pdf. NOTICE:
The reader can be set into the Standby mode or the Wake-up-by-Card mode with the command 0x64 System Reset, see system manual H60410-xe-ID-B. The command can be executed via the RS232-TTL interface only and not via the USB interface. Page 14 of 21 IDENTIFICATION CPR74 6 Indicators / LEDs The reader modules has two LED indicators on board (green and red) After power on or after a CPU Reset both LEDs starts blinking synchronously for about 2s. While operation the LEDs signalizes the following operating status:
LED - green flashes Reader is ready for operation but has no host communication shine:
Polling-Mode: Reader is ready for work and has communication with the host. Scan-Mode: Reader is working in Scan-Mode. LED - rot Communication with the Transponder (Tag detect). The picture shows the position of the green and red LED. Figure 8: Position of the green and red LED Page 15 of 21 IDENTIFICATION CPR74 7 Installation notes Be aware of the following possible environmental factors when installing an ID CPR74 into another device :
Effects from nearby metal objects Detuning of the integrated antenna Impaired communication of the antennas magnetic field EMC effects on cables Impaired communication between reader and transponder EMC effects from magnetic fields Impaired communication between reader and transponder 7.1 Metallic surroundings When installing an ID CPR74 into another device, be sure that there are no metal surfaces or objects in the direct vicinity of the reader if possible. These can detune the antenna and thus reduce the magnetic field of the integrated antenna. This will in turn result in reduced read distances for the reader. The distance between the reader and a metal surface should be at least 3 cm. Note that even other circuit boards may act like metal objects depending on how much copper they contain. If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping the distance as great as possible. The area between the antenna and transponder as well as the area on the other side of the transponder should also be kept clear of metal parts. Since any change in the metallic environment will result in detuning of the integrated antenna and therefore to impaired function, no moving metal parts, such as metallic fans, should be allowed in the vicinity of the reader. 7.2 EMC effects on cables In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can result in impairment of the communication between the reader and transponder. When installing an ID CPR74 into another device, be sure therefore that a clean, noise-free power supply is used. Page 16 of 21 IDENTIFICATION CPR74 7.3 EMC effects from magnetic fields The communication principle of RFID- Technology is based on the modulation of electromagnetic fields. Alternating magnetic fields in the vicinity of the antenna can have a negative influence on the reader function. Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. When determining the position of the reader and antenna within a device, check the device for any possible sources of interference as described above. If necessary, use shielding to suppress such interference. Page 17 of 21 IDENTIFICATION CPR74 8 Technical Data Tab. 3: Technical data Weight Temperature Range Humidity MTBF Power Supply Current Consumption USB RS232-TTL Interfaces Driver ID CPR74 approx. 20 g Operating Storage
-25 C up to +70 C (-13 F up to +158 F)
-40 C up to +85 C (-40 F up to +185 F) max. 95 % (not condensing) 500 000 h
+5 V DC 5 %
Ripple:
0...250 kHz < 10 mVpp from 250 kHz < 0,1 mVpp
< 500 mA (without SAM) Standby-Mode/Sleep-Mode Full-Speed (12 Mbit/s), Self-Powered Device 4 800 230 400 Baud Windows Server 2012 and 2016 Windows 7, 8 and 10 32/64 Bit Software Development Kits Windows (C++, .NET, Java), Linux (C++, Java), Raspberry Pi I/Os RFID Interface Operating Frequency Output Power Antenna Connection Supported Transponder Types (contactless) Contact Interface 3 digital outputs; max. 20 mA 2 LEDs (green, red) ISO 14443-A/-B (106 848 kBit/s) ISO 15693, ISO 18000-3M3 13,56 MHz 450 mW U.FL-Socket for external antenna ISO/IEC 14443-4, mifare classic, mifare UltraLight, mifare DESFire, mifare PLUS, mifare UltraLight C, my-d move, JewelTM, FeliCa. Tag-It HFI, Fujitsu MB89R11x, STM24LRx, STMLRI2k, I-Code SLI/SLIX, I-Code ILT NFC Devices in Card Emulation Mode (Tag Type 14), NFC Peer-to-Peer (P2P) 4 SAM-Module (size ID000) according to ISO 7816 T=0 and T=1 Protocol, Power Class A, B & C Page 18 of 21 IDENTIFICATION CPR74 Operating Modes ISOHost Mode ( Polling Mode), Scan-Mode Europe UK USA Canada Radio Approval EMV Safety and Health Waste and Hazardous Substances Miscellaneous EN 300 330 EN 300 330 FCC 47 CFR Part 15 IC RSS-210 EN 301 489 ISO 11452-2/-4 (Functional status C) EN 62368-1 EN 50364 WEEE - 2002/96/EC RoHS - 2011/65/EC Tested according EMVCo Contact Level 1 Certification suitability according EMVCo Contactless Level 1, VDV-KA,ITSO and in the future CEN/TS 16794 (see chapter: Characterization ID CPR74) Page 19 of 21 IDENTIFICATION CPR74 9 Radio Approvals 9.1 Declaration of Conformity (CE), (UKCA), (PJMCPR40), (6633A-CPR40) CE Konformittserklrung Hiermit erklrt FEIG ELECTRONIC GmbH, dass der Funkanlagentyp ID CPR74 der Richtlinie 2014/53/EU entspricht. Der vollstndige Text der EU-Konformittserklrung ist unter der folgenden Internetadresse verfgbar:
https://www.feig.de/en/service/eu-declarations-of-
conformity/
UKCA Declaration of Conformity CE Declaration of Conformity Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID CPR74 is in compliance with directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
https://www.feig.de/en/service/eu-declarations-of-conformity/
Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID ID CPR74 is in compliance with directive No. 1206 Radio Equipment Regulations 2017. The full text of the UKCA declaration of conformity is available at the following internet address:
https://www.feig.de/en/service/ukca-declarations-of-conformity/
9.2 USA (FCC) and Canada (IC) Product name:
ID CPR74 FCC ID:
IC:
Notice for USA and Canada PJMCPR74 6633A-CPR74 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. Page 20 of 21 IDENTIFICATION CPR74 Installation with FCC / IC Approval:
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States / Canada. Page 21 of 21
1 2 | PAD74-U - Installation Manual | Users Manual | 670.01 KiB | December 19 2023 / January 04 2024 |
IDENTIFICATION INSTALLATION ID PAD74-U PAD Reader with USB Interface M30521-1e-ID-B IDENTIFICATION ID PAD74-U NOTE Copyright by FEIG ELECTRONIC GmbH Industriestrae 1a D-35781 Weilburg (Germany) Tel.: +49 6471 3109-0 https://www.feig.de/en/
identification-support@feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guarantee for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. All brand names, trademarks or logos are the property of their respective owners. INSTALLATION Page 2 of 15 IDENTIFICATION ID PAD74-U Safety Instructions The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes. When working on devices the valid safety regulations must be observed. Before touching the device, the power supply must always be interrupted. Make sure that the device is without voltage by measuring. The fading of an operation control (LED) is no indicator for an interrupted power supply or the device being out of voltage!
Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in the immediate proximity of the devices antenna for any length of time. INSTALLATION Page 3 of 15 IDENTIFICATION ID PAD74-U Content 1 1.1 1.2 1.3 2 3 3.1 3.2 4 4.1 4.2 ID PAD74-U PAD Reader with USB-Interface 5 Scope of delivery ............................................................................................................... 5 Available Software-Tools, USB drivers and Firmware .................................................... 6 Difference between ID PAD74-U and ID CPR74-CUSB .................................................... 6 Dimension Installation 7 9 Table top mounting ........................................................................................................... 9 Under table mounting ........................................................................................................ 9 Commissioning 12 DC Power supply ............................................................................................................. 12 LED Indication ................................................................................................................. 12 5 Radio Approvals 13 5.1 Declaration of Conformity (CE), (UKCA) ........................................................................ 13 6 7 Technical Data Cleaning / Care 14 15 INSTALLATION Page 4 of 15 IDENTIFICATION ID PAD74-U 1 ID PAD74-U PAD Reader with USB-Interface The ID PAD74-U is an RFID PAD reader for contactless data exchange with passive transponders and combines a reader and an antenna in one housing. The compact format allows the PAD74-U to be positioning "on" and "under" any nonmetallic mounting or table top. It is suitable for many desktop applications in offices, industry or libraries (output and return). The high processing speed and easy configuration allow ideal adaptation to the customer application. There are three status LEDs (color green. blue. red) on the front side, which indicates the status of the reader with antenna (see 4.2 LED Indication). Supported Standards Features ISO 15693 ISO 18000-3 Mode1 Operating Frequency f = 13,56 MHz Max. RF Transmitting Power Antenna Connection P = 400 mW fixed cable USB Interface Protection Class IP30 Status LED LED (green, blue, red) Table 1: Features 1.1 Scope of delivery ID PAD74-U PAD Reader with USB-Interface Document Quickstart INSTALLATION Page 5 of 15 IDENTIFICATION ID PAD74-U 1.2 Available Software-Tools, USB drivers and Firmware The service software and the corresponding USB driver (HF/UHF reader or FEIG ID driver) for personal computers with Microsoft Windows operating systems, are available on the Feig homepage under "Service -> Driver". Further documents and software tools can be found under the link:
https://www.feig.de/en/login/
Login: CPR74 Password : FE900 NOTE:
The Reader ID PAD74-U reports itself in ISOStart+ 2023 (version 11.08.xx or higher) as "ID CPR74". A firmware update tool and an xml firmware file are available for firmware updates. 1.3 Difference between ID PAD74-U and ID CPR74-CUSB The reader module installed in the ID PAD74-U does not support all commands and functions that are available in the reader module ID CPR74-CUSB.
(see Manual H60410-Xe-ID-B) Since ISO 15693 and ISO 14443-A/B transponders are mainly used in the intended applications, the following transponder drivers have been switched off in the reader configuration and cannot be activated. Unavailable functions and transponder drivers:
ISO 18000-3M3 NOTE:
The ID PAD74-U rejects the activation of an invalid transponder driver" with the error message
"Parameter Range Error". The commands of the internal reader ID CPR74-CUSB belonging to the disabled transponder driver are not available. In the factory default state, the provided antenna (ANT2) inside ID PAD74-U is activated. The internal antenna installed on the reader module ID CPR74-CUSB can additionally be activated via the reader configuration. INSTALLATION Page 6 of 15 IDENTIFICATION ID PAD74-U 2 Dimension Figure 1: Front view Figure 2: Top view with housing dimension INSTALLATION Page 7 of 15 IDENTIFICATION ID PAD74-U Figure 3: Drilling pattern under table mounting INSTALLATION Page 8 of 15 IDENTIFICATION ID PAD74-U 3 Installation The PAD74-U is designed for operation on a non metallic, flat surface (e.g. table) or for under table mounting (non metallic) indoors. Device connection via USB cable (2.3 m) The cable length must not be changed. 3.1 Table top mounting Positioning the device on the table top. The rubber feet on the bottom of the case prevent it from moving. Figure 4: Table top mounting 3.2 Under table mounting Please follow the instructions in the Table 2: "Instructions for under table mounting". Figure 5: Under table mounting INSTALLATION Page 9 of 15 IDENTIFICATION ID PAD74-U Remove rubber feet Use drilling pattern,
(see Fig. 3) The predrilled holes (2.0 mm) are located under the rubber feet. Drill out factory holes from 2.0 mm to 4.0 mm The under-table mounting is carried out via the rear of the housing using pan head screws
(max. M3 x 3.5 mm). The four pan head screws must penetrate the top of the antenna. Figure 6: Remove rubber feet Figure 7: Predrilled holes (2.0 mm) Figure 8: Drill out factory holes to 4.0 mm Figure 9: Pan head screws (max. M3 x 3.5 mm) INSTALLATION Page 10 of 15 IDENTIFICATION ID PAD74-U The antenna is aligned with the top
(front foil side) facing up and mounted. Figure 10: Under table mounting NOTE:
Before mounting, the rubber feet must be removed. Use drilling pattern Drilling holes at locations other than provided in drilling pattern, will destroy the electronics. Make sure that the surface of the tabletop is not damaged. The length of the screws must be dimensioned according to the table top thickness. The table top must not be made of metal or magnetically materials. If the mounting/table top is too thick (wood, plastic), the reading range is reduced (ideally < 25 mm). Table 2: Under table mounting INSTALLATION Page 11 of 15 IDENTIFICATION ID PAD74-U 4 Commissioning Device connection via USB cable (2.3 m) The cable length must not be changed. The device has no ON/OFF switch. All functions (status displays, transponder detection) are displayed via the status LEDs (green, blue, red) and are available after the startup process
(see 4.2 LED Indication) The standard reader configuration can be adapted to the application using the ISOStart service software from version 11.07.xx or higher The service software can be found on the download area of FEIG ELECTRONIC GmbH at https://www.feig.de/en/
4.1 DC Power supply U = 5 VDC Imax = 500 mA Via USB 2.0 4.2 LED Indication LED-Signal Description Green LED / RUN LED flashes Reader is in Host-Mode Green LED / RUN LED is on Reader is in Scan-Mode Blue LED is on (1 s) Transponder detected Green and red LED flashes alternately ERROR message Table 3: LED Indication INSTALLATION Page 12 of 15 IDENTIFICATION ID PAD74-U 5 Radio Approvals 5.1 Declaration of Conformity (CE), (UKCA) CE Declaration of Conformity Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID PAD240-U is in compliance with directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
https://www.feig.de/en/service/eu-declarations-of-conformity/
UKCA Declaration of Conformity Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID PAD240-U is in compliance with directive No. 1206 Radio Equipment Regulations 2017. The full text of the UKCA declaration of conformity is available at the following internet address:
https://www.feig.de/en/service/ukca-declarations-of-conformity/
INSTALLATION Page 13 of 15 IDENTIFICATION ID PAD74-U 6 Technical Data Wight:
Dimension:
(L x W x H) Front cover:
Housing:
Protection class:
Color:
PAD Upper side Operating frequency:
Max. RF transmitting power:
Power supply:
Max. Power consumption:
Interface:
LED Indicator:
Supported Transponder:
Reader Mode :
Temperature range:
Operation Storage Relative air humidity:
Radio license:
Europe UK USA Canada EMC:
Safety & Health:
Table 4: Technical Data Mechanical Data approx. 0,5 kg
(240 x 180 x 13) mm3
(9,45 x 7,08 x 0,51) in3 Insensitive surface ABS IP30 RAL 9003 (white) black Electrical Data 13,56 MHz P = 400 mW 5 V DC via USB P = 2,5 W USB 2.0 3 x LEDs (green, blue, red) ISO 15693 ISO 14443-A/B NFC Tag Type 1-4 ISO 18000-3 MODE 1 e. g. EM HF ISO Chips, Fujitsu HF ISO Chips, Infineon my-d, KSW Sensor Chips, NXP ICODE SLI family, STM ISO Chips, TI Tag-it, NXP MIFARE family, NFC Devices in Card Emulation Mode
(Tag Type 15) ISO Host Mode Scan Mode 25 C bis +55 C
(13 F up to 131 F) 25 C bis +70 C
(13 F up to 158 F) 5 % bis 95 %
(no condensing) Standard conformity EN 300 330 EN 300 330 FCC 47 CFR Part 15 IC RSS-GEN, RSS-210 EN 301 489 EN 62368-1, EN 50364 INSTALLATION Page 14 of 15 IDENTIFICATION ID PAD74-U 7 Cleaning / Care Clean surfaces with clean, soft microfiber cloth and a solution of water with a little detergent. NOTE:
Using the wrong cleaning agents or cleaning cloths can damage the surface of the front foil. Do not use harsh, solvent-based or corrosive cleaning agents. Document:
Id-No. Document Version:
Date:
Installation ID PAD74-U M30521-1e-ID-B 01.09.2023 Copyright All brand names, product names or trademarks cited are the property of their respective owners. FEIG ELECTRONIC GmbH Industriestrae 1a 35781 Weilburg, Germany Phone: +49 6471 3109-0 Homepage:
Email:
https://www.feig.de/en/
identification-support@feig.de INSTALLATION Page 15 of 15
1 2 | UserManual | Users Manual | 520.33 KiB |
MANUAL ID CPR74 RFID-Readermodul Modell ID CPR74-4SCUSB ID CPR74-CUSB Artikel-Nr.. 4607.000.00 4606.000.00 priliminary public (B) 2016-09-26 CPR74-Manual M60610-0e.docx Installation Note ID CPR74 OBID classic-pro Copyright 2016 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID i-scan is a registered trademark of FEIG ELECTRONIC GmbH. All brand names, trademarks or logos are property of their respective owners. FEIG ELECTRONIC GmbH Page 2 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro Installation Content ID CPR74 1. Safety Instructions / Warning - Read before start-up !
4 2. Characterization ID CPR74 5 2.1. Scope of delivery .................................................................................................................. 6 2.2. Available Accessories ......................................................................................................... 6 2.3. Available Software Tools, USB Driver and Firmware ....................................................... 6 3. Dimensions 7 4. Installation and wiring 8 4.1. Connector X1, X2 .................................................................................................................. 8 4.2. Digital Outputs ...................................................................................................................... 9 4.3. Connection of an external Antenna .................................................................................. 10 4.4. SAM Slots ............................................................................................................................ 11 4.4.1. Installation of a SAM Card in a SAM Socket ................................................................ 12 5. Power supply 13 5.1. Power via USB Interface .................................................................................................... 13 5.2. Standby- / Wake-up-by-Card-Mode ................................................................................... 13 6. Indicators / LEDs 14 7. Installation notes 15 7.1. Metallic surroundings ........................................................................................................ 15 7.2. EMC effects on cables ....................................................................................................... 15 7.3. EMC effects from magnetic fields ..................................................................................... 16 8. Technical Data 17 9. Approvals 19 9.1. Europa (CE) ......................................................................................................................... 19 9.2. USA (FCC) and Canada (IC) ............................................................................................... 20 FEIG ELECTRONIC GmbH Page 3 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro Installation ID CPR74 1. Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorised changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorised measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pace-
maker and not stay in an immediate proximity of the device respective the antenna for some time. FEIG ELECTRONIC GmbH Page 4 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro 2. Characterization ID CPR74 Installation ID CPR74 The reader modules ID CPR74 are designed for data exchange (read and write) with passive tran-
sponder according ISO14443 type A and type B, ISO15693, ISO18000-3M3 and are capable for communication with NFC devices (ISO18092). The small dimensions and the different available interfaces (RS232-TTL or USB) make it suitable for an easy integration into terminals, housings and other devices. The following different types of reader modules are available:
ID CPR74-4SCUSB ID CPR74-CUSB Dimensions L x B x H Power supply Antenna:
internal external SAM Socket Digital outputs Interface RS232-TTL USB full-speed (12Mbit/s) 50 mm x 68 mm x 10 mm 50 mm x 68 mm x 8 mm 5 V DC 5 %
-
4 3 The variant ID CPR74-4SCUSB is equipped with 4 sockets for Security Access Modules (SAM) in the ID000 format. Because of the SAM current consumption the reader module is designed as Self-Powered-Device and need a separate power supply. The voltage supply from a USB port is not sufficient in this case. Because of their high performance and a wide range of different configuration parameters the reader modules ID CPR74 is suitable for a lot of applications like eTicketing, ePayment, eDocument, eMobility and medical devices. With the help of the integrated antenna multiplexer an external antenna can be used additional to the internal antenna. In Scan Mode the reader can switch between both antenna automatically. The implemented SoftCrypto and SAMCrypto high level functions offer a comfortable and fast in-
terface for the access to the encrypted data of an mifare Desfire, mifare Plus or mifare Ultralight transponder. The reader module with a corresponding external antenna is ready for a EMVCo Contactless Level 1 certification as well as a VDV-KA certification (corresponding to BSI TR-03105 Part 4) or in the future CEN/TS 16794 approval. The certification suitability need to be evaluate for each individual case because of the used ex-
ternal antenna and the installation situation. The SAM Sockets have been approved according the EMVCo Contact Level 1 and they are eligi-
ble for the certification. FEIG ELECTRONIC GmbH Page 5 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro 2.1. Scope of delivery Installation ID CPR74 The delivery contains the following parts:
1 x RFID-Reader module ID CPR74 2.2. Available Accessories Tab. 1 Available Accessories and spare parts Part Number Part name Description 3674.000.00 ID ISC.ANT40/30-U.FL-A 3673.000.00 ID ISC.ANT100/100-U.FL-A 3540.000.00 ID ISC.ANT.C05-A 3541.000.00 ID CAB.USB-B 50 Ohm Antennae with U.FL-connector for the connection on the ID CPR74 Dimensions: 40 mm x 30 mm 50 Ohm Antennae with U.FL-connector for the connection on the ID CPR74 Dimensions: 100 mm x 100 mm 50 Ohm Antenna cable with U.FL connector on both sides for the connection of an external antenna on the ID CPR74 Dimension : 500 mm; Color: black USB-cable for the connection of the ID CPR74 on an ex-
ternal host Dimension: 2,75 m 2.3. Available Software Tools, USB Driver and Firmware The USB driver and the test and configuration tool ID CPRStart are available on our Feig down-
load area:
http://www.feig.de/en/downloads-support.html Username: CPR74 Password : FE900 For firmware updates we are providing a update tool OBIDFirmwareUpdateTool and a external firmware xml-file. FEIG ELECTRONIC GmbH Page 6 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro 3. Dimensions Installation ID CPR74 The ID CPR74 reader module has been designed for the integration into terminals, printers or handheld devices and so on. Figure 1: Dimension (Top View) Figure 2: Dimension (Side View) FEIG ELECTRONIC GmbH Page 7 of 20 CPR74-Manual M60610-
0e.docx Installation ID CPR74 OBID classic-pro 4. Installation and wiring 4.1. Connector X1, X2 The reader can be connected to a RS232-TTL interface and the power supply by using the multi-
pin connector X1. The multi-pin connector X2 provide the connection for the USB interface. The device with SAM Sockets is a self-powered USB device which requires a separate power supply. The following figure 4 and the table shows the assignment of the pins X1 (7pol.) and X2 (5pol.) Typ JST PH RM 2 mm (horizontal). Figure 3: Plug JST PH X1 X2 5 1 1 7 Figure 4: ID CPR74 - plug and connections Tab. 2 Assignment of the pins on X1 and X2 X1 Pin-No. Symbol ID CPR74 1 2 3 4 5 6 7 X2 Pin-No. 1 2 3 4 5 OUT1 OUT2 OUT3 GND*
RxD TxD VCC**
Shielding GND*
USB-D PLUS USB-D MINUS Digital Output 1 Digital Output 2 Digital Output 3 RS232-TTL RS232-TTL
+ 5 V DC 5 %
USB-Cable Shielding VCC**
+ 5 V DC 5 %
* GND are connected internal directly
** VCC are connected internal directly. Feed-In VCC only at one pin! This is especially important if the reader is connected to a USB port. Please take care!
FEIG ELECTRONIC GmbH Page 8 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro Installation ID CPR74 NOTICE:
Only one host interface can be used at the same time. Using several host interfaces at the same time can force malfunctions. The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-
ply) according IEC EN 60950-1 chapter 2.5, only Use only regulated power supplys. The connection cable (RS232TTL, USB, VCC) should be as short as possible and must be shorter than 3 m to reduce the influence of noise. Reversing the polarity of the supply voltage may destroy the device. Supply voltages outside the specifications may destroy the device. If switching power supplies are used with the module, be sure that there is adequate fil-
tering. Noise from the power supply can result in a reduction of the read/write range of the module. 4.2. Digital Outputs The Figure 5 shows the circuit diagram of the digital outputs OUT1 OUT3. The digital outputs are intended for the connection of external LEDs. Figure 5: Wiring of digital outputs OUT1...3 FEIG ELECTRONIC GmbH Page 9 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro Installation ID CPR74 4.3. Connection of an external Antenna The ID CPR74 modules are equipped with an internal 50 -antenna and have an addi-
tionally connector for an external 50 -antenna. In Scan mode it is possible to switch between the two antennas automatically. In the ISOHost Mode the switching of the antenna can be performed by commands. The use of the external antenna is configurable in the reader settings. The connection of the external antenna is possible via the U.FL connector ANT. Optional it is possible to integrate a 2-pin SMD connector (spacing 2,54 mm) on position X6. X6:
Optionale 2 pol. SMD Stift-
leiste ANT:
(U.FL) Figure 6: Connection of an external antenna The technical description and hints for building external 50 -antennas can be taken from the application note N20901-#d-ID-B.pdf. Name ANT X6 Description Subminiature Coaxial connector for an external 50 -antenna Optional 2pin. connector for an external 50 -antenna NOTICE:
Only for use with 50 matched external antennas. The permanent usage of unmatched antennas can damage the reader electronic. The antenna output is neither permanent short circuit protected nor permanent no-load protected. The antenna cable should be no longer than 1m. The use of other cable length are pos-
sible after consulting the manufacturer. FEIG ELECTRONIC GmbH Page 10 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro 4.4. SAM Slots Installation ID CPR74 Figure 7 shows the position of the 4 SAM slots (S1-4). Each SAM slot is designed for a ID000 formatted SAM Card. NOTICE Wrong inserted SAM cards and forcefully opening or closing can damage the SAM slot. See chapter: 4.4.1. Installation of a SAM Card in a SAM Figure 7: Position of the 4 SAM Sockets FEIG ELECTRONIC GmbH Page 11 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro Installation ID CPR74 4.4.1. Installation of a SAM Card in a SAM Socket The following step by step instruction shows the installation of a SAM Card into the SAM socket S1. 1. Closed SAM socket without SAM card. 2. Push the latch to the right side and open the cover carefully. 3. Put the SAM card into the cover. The contact plate face up and the beveled corner outside 4. The SAM card must be pushed up against the stop angle. 5. The SAM card must not be inserted with the beveled corner first. 6. Close the top cover with carefully pressure to snap into place. Push the latch to the left side. FEIG ELECTRONIC GmbH Page 12 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro 5. Power supply Installation ID CPR74 The reader ID CPR74-SCUSB with 4 SAM slots is designed as a Self-Powered USB Device and needs an additional 5 V DC power supply. The power supply must meet the following specification:
+5 V DC 5 %
Ripple:
0...250 kHz < 10 mVpp from 250 kHz < 0,1 mVpp Note:
On both device variants you need to take care that the voltage supply of the USB port is not connected in the case if an external power supply is connected. 5.1. Power via USB Interface The reader ID CPR74-CUSB (without SAM-Sockets) can be optional powered via a High Powered USB port (500mA). 5.2. Standby- / Wake-up-by-Card-Mode The Standby mode or the Wake-up-by-Card function can be configured in the reader configura-
tion. See system manual H60410-xe-ID-B.pdf. NOTICE:
The reader can be set into the Standby mode or the Wake-up-by-Card mode with the command 0x64 System Reset, see system manual H60410-xe-ID-B. The command can be executed via the RS232-TTL interface only and not via the USB interface. FEIG ELECTRONIC GmbH Page 13 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro Installation ID CPR74 6. Indicators / LEDs The reader modules has two LED indicators on board (green and red) After power on or after a CPU Reset both LEDs starts blinking synchronously for about 2s. While operation the LEDs signalizes the following operating status:
LED - green flashes:
Reader is ready for operation but has no host communication shine:
Polling-Mode:
Reader is ready for work and has communication with the host. Scan-Mode:
Reader is working in Scan-Mode. LED - rot Communication with the Transponder (Tag detect). Figure 8 shows the position of the green and red LED. Figure 8: Position of the green and red LED FEIG ELECTRONIC GmbH Page 14 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro 7. Installation notes Installation ID CPR74 Be aware of the following possible environmental factors when installing an ID CPR74 into another device :
Effects from nearby metal objects Detuning of the integrated antenna Impaired communication of the antennas magnetic field EMC effects on cables Impaired communication between reader and transponder EMC effects from magnetic fields Impaired communication between reader and transponder 7.1. Metallic surroundings When installing an ID CPR74 into another device, be sure that there are no metal surfaces or ob-
jects in the direct vicinity of the reader if possible. These can detune the antenna and thus reduce the magnetic field of the integrated antenna. This will in turn result in reduced read distances for the reader. The distance between the reader and a metal surface should be at least 3 cm. Note that even other circuit boards may act like metal objects depending on how much copper they contain. If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping the distance as great as possible. The area between the antenna and transponder as well as the area on the other side of the tran-
sponder should also be kept clear of metal parts. Since any change in the metallic environment will result in detuning of the integrated antenna and therefore to impaired function, no moving metal parts, such as metallic fans, should be allowed in the vicinity of the reader. 7.2. EMC effects on cables In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can result in impairment of the communication between the reader and transponder. When installing an ID CPR74 into another device, be sure therefore that a clean, noise-free power supply is used. FEIG ELECTRONIC GmbH Page 15 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro Installation ID CPR74 7.3. EMC effects from magnetic fields The communication principle of RFID- Technology is based on the modulation of electromagnetic fields. Alternating magnetic fields in the vicinity of the antenna can have a negative influence on the reader function. Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. When determining the position of the reader and antenna within a device, check the device for any possible sources of interference as described above. If necessary, use shielding to suppress such interference. FEIG ELECTRONIC GmbH Page 16 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro 8. Technical Data Tab. 3: Technical data Weight Temperature Range Humidity MTBF Power Supply Current Consumption Interfaces USB RS232-TTL Driver Installation ID CPR74 ID CPR74 approx. 20 g Operating Storage
-25 C up to +70 C (-13 F up to +158 F)
-40 C up to +85 C (-40 F up to +185 F) max. 95 % (not condensing) 500 000 h
+5 V DC 5 %
Ripple:
0...250 kHz < 10 mVpp from 250 kHz < 0,1 mVpp
< 500 mA (without SAM) Standby-Mode/Sleep-Mode Full-Speed (12 Mbit/s), Self-Powered Device 4 800 230 400 Baud OBID USB Driver, PC/SC-Driver (WHQL) Windows Server 2003 und 2008, Windows Vista 32/64 Bit, Windows 7 32/64 Bit, Windows 8 32/64 Bit, Windows 10 32/64 Bit, Windows CE Software Development Kits Windows, Windows CE and Linux (C++, .NET, JAVA) I/Os RFID Interface Operating Frequency Output Power Antenna Connection Supported Transponder Types (contactless) Contact Interface Operating Modes 3 digital outputs; max. 20 mA 2 LEDs (green, red) ISO 14443-A/-B (106 848 kBit/s) ISO 15693, ISO 18000-3M3 13,56 MHz 450 mW U.FL-Socket for external antenna ISO/IEC 14443-4, mifare classic, mifare UltraLight, mifare DESFire, mifare PLUS, mifare UltraLight C, my-d move, JewelTM, FeliCa. Tag-It HFI, Fujitsu MB89R11x, STM24LRx, STMLRI2k, I-Code SLI/SLIX, I-Code ILT NFC Devices in Card Emulation Mode (Tag Type 14), NFC Peer-to-Peer (P2P) 4 SAM-Module (size ID000) according to ISO 7816 T=0 and T=1 Protocol, Power Class A, B & C ISOHost Mode ( Polling Mode), Scan-Mode FEIG ELECTRONIC GmbH Page 17 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro Installation ID CPR74 Europe USA Canada Radio Approval EMV Safety and Health Waste and Hazardous Substances Miscellaneous EN 300 330 FCC 47 CFR Part 15 IC RSS-210 EN 301 489 EN 62368 EN 50364 WEEE - 2002/96/EC RoHS - 2011/65/EC Tested according EMVCo Contact Level 1 Certification suitability according EMVCo Contactless Level 1, VDV-KA,ITSO and in the future CEN/TS 16794 (see chap-
ter: 2. Characterization ID CPR74) FEIG ELECTRONIC GmbH Page 18 of 20 CPR74-Manual M60610-
0e.docx Installation ID CPR74 OBID classic-pro 9. Approvals 9.1. Europa (CE) Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID CPR74 is in com-
pliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
http://www.feig.de/en/downloads-support/declarations-of-conformity.html Performance Classification according to ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Page 19 of 20 CPR74-Manual M60610-
0e.docx OBID classic-pro 9.2. USA (FCC) and Canada (IC) Product name:
FCC ID:
IC:
Installation ID CPR74 ID CPR74 PJMCPR74 6633A-CPR74 Notice for USA and Canada This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux condi-
tions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. Installation with FCC / IC Approval:
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada. FEIG ELECTRONIC GmbH Page 20 of 20 CPR74-Manual M60610-
0e.docx
1 2 | ID Label/Location Info | ID Label/Location Info | 323.56 KiB | December 19 2023 / January 04 2024 |
Test report no. 23012926_Rev. 01 Page 1 of 3
---RADIO--------------------RADIO--------------------RADIO-------------------- RADIO-------------------- RADIO-------------------- RADIO Date of issue: 2023-11-08 EUT: ID CPR74 FCC Title 47 CFR Part 15 FCC ID: PJMCPR74 Annex acc. to FCC Title 47 CFR Part 15 relating to FEIG ELECTRONIC GmbH ID CPR74 with antennas ID PAD74-U ID PAD240/180-B Annex no. 4 Label sample Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C Intentional Radiators Measurement Procedure:
ANSI C63.4-2014 ANSI C63.10-2013 TV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Building 10, Waltherstr. 49-51, 51069 Cologne, Germany V1.23 Tel.: +49 221 8888950 hf@tuev-nord.de Test report no. 23012926_Rev. 01 Page 2 of 3
---RADIO--------------------RADIO--------------------RADIO-------------------- RADIO-------------------- RADIO-------------------- RADIO Date of issue: 2023-11-08 EUT: ID CPR74 FCC Title 47 CFR Part 15 FCC ID: PJMCPR74 Label sample of EUT TV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Building 10, Waltherstr. 49-51, 51069 Cologne, Germany V1.23 Tel.: +49 221 8888950 hf@tuev-nord.de Test report no. 23012926_Rev. 01 Page 3 of 3
---RADIO--------------------RADIO--------------------RADIO-------------------- RADIO-------------------- RADIO-------------------- RADIO Date of issue: 2023-11-08 EUT: ID CPR74 FCC Title 47 CFR Part 15 FCC ID: PJMCPR74 Label location TV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Building 10, Waltherstr. 49-51, 51069 Cologne, Germany V1.23 Tel.: +49 221 8888950 hf@tuev-nord.de
1 2 | Annex no.11 Antenna requirements | Test Report | 408.06 KiB | December 19 2023 / January 04 2024 |
1 2 | Attestation Statements | Attestation Statements | 125.61 KiB | December 19 2023 / January 04 2024 |
Page 1 of 1 09-10-2023 Certification Application Attestation Statements FEIG ELECTRONIC GmbH Industriestr. 1a 35781 Weilburg Germany To Whom It May Concern:
Statement for 47 CFR section 2.911(d)(5)(i) Feig Electronic certifies that as of the date of the application the equipment for which authorization is sought is not covered equipment1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not covered equipment. Additional Explanation: <N/A>
Statement for 47 CFR section 2.911(d)(5)(ii) Feig Electronic (the applicant) certifies that, as of the date of the filing of this application, the applicant
- is /
- is not identified on the Covered List as an entity producing covered equipment. Date:
City:
Name(2) :
Function:
Telephone number:
Email address:
Signature:
December 12, 2023 35781 Weilburg Alexander Lind Development Engineer
+49 6471 3109-529 Alexander.lind@feig.de ________________________________
(1): The Commissions Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commissions website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes covered equipment. https://www.fcc.gov/supplychain/coveredlist .
(2): For FCC it must be the Grantee Code owner or the authorized agent.
1 2 | Class II permissive change letter | Cover Letter(s) | 25.00 KiB | December 19 2023 / January 04 2024 |
06.12.2023 FEIG ELECTRONIC GmbH Industriestrasse 1a 35781 Weilburg / Germany Federal Communications Commission 445 12th Street, SW Washington, DC 20554 Certification and Engineering Bureau Industry Canada Spectrum Engineering Branch 3701 Carling Avenue, building 94 Ottawa, Ontario K2H 8S2 Intentional Radiator Applicant: FEIG ELECTRONIC GmbH Equipment: RFID reader, operating frequency 13.56 MHz Model: ID CPR74 FCC ID: PJMCPR74 (Approval Date: 16.11.2016) IC ID: 6633A-CPR74 (Approval Date: 18.11.2016) Pursuant to Part 15.225 Certification and RSS-210 Issue 10, FEIG ELECTRONIC GmbH requests a Permissive Change Class 2 for the device ID CPR74. Modifications:
- New antennas, model numbers:
ID PAD74-U ID PAD240/180-B The mentioned RFID antennas have identical components, identical connectors and identical housing. Both versions use the same printed circuit board. The only difference between them is the front cover. Should you have any questions, please feel free to contact the undersigned. Sincerely, Name of applicant: Alexander Lind Company: Feig Electronic GmbH Address: Industriestr. 1a, 35781 Weilburg / Germany Phone: +49 6471 3109 0 Fax: +49 6471 3109 99 Email: alexander.lind@feig.de 1
1 2 | Confidentiality | Cover Letter(s) | 68.04 KiB | December 19 2023 / January 04 2024 |
FCC, Request for non-disclosure RF_501, Issue 8 Date: 09-Oct-2023 Page 1 of 1 Company Name: Feig Electronic GmbH Address:
City:
Country:
Industriestr. 1a 35781 Weilburg Germany To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: PJMCPR74 Reference number: ######
Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application:
Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commissions policy, in order to comply with the marketing regulations in 47 CFR 2.803 and the importation rules in 47 CFR 2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below):
Internal Photos Users Manual Test Set-up Photos External Photos Justification:
Date: 09.10.2023 Name and signature of applicant: Alexander Lind Notes:
1) A document or type of document can only have ONE type of confidentiality!
2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)!
The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this!
5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
1 2 | Declaration of authorization | Cover Letter(s) | 196.83 KiB | December 19 2023 / January 04 2024 |
Declaration of Authorization We Name:
Address:
City:
Country:
Declare that:
FEIG ELECTRONIC GmbH Industriestr. 1a 35781 Weilburg Germany Name Representative of agent:
Agent Company name:
Address:
City:
Country Ralf Trepper TV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebude 10, Waltherstr. 49-51 51069 Kln Germany is authorized to apply for Certification of the following product(s):
Product description: RFID Reader Type designation:
ID CPR74 Trademark:
Validity/ expiry date: -
FEIG ELECTRONIC on our behalf. Date:
City:
Name:
Oct. 09, 2023 Weilburg Elmar Reichwein Function:
Senior Development Engineer Signature:
1 2 | Declaration of authorization use of TCF | Cover Letter(s) | 246.05 KiB | December 19 2023 / January 04 2024 |
Declaration of Authorization (to use documentation) We Name:
Address:
City:
Country:
FEIG ELECTRONIC GmbH Industriestr. 1a 35781 Weilburg Germany Declare that:
Name:
Agent Company name:
Address:
City:
Country Ralf Trepper TV NORD Hochfrequenztechnik GmbH & Co. KG LESKANPARK, Gebude 10, Waltherstr. 49-51 51069 Kln Germany may use our test reports and documentation of the following (already certified) product:
Product description: RFID Reader Type designation:
Trademark:
ID CPR74 FEIG ELECTRONIC Original FCC ID: PJMCPR74 Original Canada ID: 6633A-CPR74 Original Japan certificate number: . for his own approval/certificate. Date:
City:
Name:
09.10.2023 Weilburg Elmar Reichwein Function:
Senior Development Engineer Signature:
1 2 | Equality Declaration | Cover Letter(s) | 115.50 KiB | December 19 2023 / January 04 2024 |
Equality Declaration ID PAD240/180-B and PAD74-U 1 / 1 Date :
2023-09-12 We, FEIG ELECTRONIC GmbH Industriestrae 1a 35781 Weilburg Germany Declare that the products RFID antenna with integrated reader ID PAD74-U ID PAD240/180-B have identical components, identical connectors and identical housing. Both versions use the same printed circuit board. The only difference between PAD74-U and PAD240/180-B is the front cover. Name:
Title:
Alexander Lind Hardware Engineer Company:
FEIG ELECTRONIC GmbH Date: 2023-09-12
(Signature) Address:
Industriestr. 1a 35781 Weilburg Germany Email:
Phone:
alexander.lind@feig.de
+49 6471 3109 529
1 2 | US agent | Attestation Statements | 65.67 KiB | December 19 2023 / January 04 2024 |
Designated U.S. Agent Viki Reg FEIG U.S. Agent Designation for Service of Process
(Applicant and U.S. Agent are Separate Parties) TO Kiwa Nederland B.V Wilmersdorf 50 7327 AC Apeldoom Postbus 137 7300 AC Apeldoom Netherlands ATTENTION: FCC Certification Section 2.911(d)(7) Information Company name FEIG ELECTRONICS Inc. FCC registration number: 0033651084 Contact person name: Deborah Greenway Street address: 2220 Northmont Parkway ZIP/City/State 30096 Duluth, GA Telephone number: +1 (770) 4918060 - 233 Email address: dgreenway@feig-electrgnics.com Signature:
Date: October 17, 2023 This letter is to confirm that we (the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.91 1(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. licant Company name: Feig Electronic GmbH FCC reaistration number: 0007634793 Grantee Code PJM Contact person name: Elmar Reichwein Street address Industriestr. 1a ZIP/City/State 35781 Weilburg / Germany Telephone number: +49 6471 3109-438 Email address: elmar.reichwein@feig.de Signature 2? a pean ge ~
Date: October 09, 202 FEIG ELECTRONIC GmbH Geschattstiinrung: Bankverbindung:
IndustriestraBe la Dipl.-Ing. Wolfgang Feig, Eldor Walk Kreissparkasse Weilburg, BIC: HELADEFIWE!
D-35781 Weilburg Amtsgericht Limburg HRB 3178 IBAN: DE38 $115 19190100 4510 12 Tel.: +49 6471 3109-0, Fax; -99 USt-IdNr.: DE 811 460 661, St.-Nr.: 020 233 10679 Commerzbank AG, BIC; DRESOEFFS13 iInfo@teig de, www.feig.de WEEE-Reg.-Nr.: DE 34765740 IBAN: DE6O 5136 0040 0936 7354 00
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2024-01-04 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Class II Permissive Change |
2 | 2016-11-16 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2024-01-04
|
||||
1 2 |
2016-11-16
|
|||||
1 2 | Applicant's complete, legal business name |
Feig Electronic GmbH
|
||||
1 2 | FCC Registration Number (FRN) |
0007634793
|
||||
1 2 | Physical Address |
Industriestrasse 1a
|
||||
1 2 |
Lange Strae 4
|
|||||
1 2 |
Weilburg-Waldhausen, N/A
|
|||||
1 2 |
Weilburg-Waldhausen, N/A D-35781
|
|||||
1 2 |
Germany
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
c******@telefication.com
|
||||
1 2 |
O******@cetecom.com
|
|||||
1 2 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
PJM
|
||||
1 2 | Equipment Product Code |
CPR74
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
E**** R********
|
||||
1 2 | Title |
Manager
|
||||
1 2 | Telephone Number |
+49 6********
|
||||
1 2 | Fax Number |
+49 6********
|
||||
1 2 |
e******@feig.de
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
FEIG ELECTRONIC GmbH
|
||||
1 2 | Name |
A**** L********
|
||||
1 2 | Physical Address |
Industriestrasse 1a
|
||||
1 2 |
Weilburg-Waldhausen
|
|||||
1 2 |
Germany
|
|||||
1 2 | Telephone Number |
49 64********
|
||||
1 2 | Fax Number |
49 64********
|
||||
1 2 |
a******@feig.de
|
|||||
app s | Non Technical Contact | |||||
1 2 | Firm Name |
FEIG ELECTRONIC GmbH
|
||||
1 2 | Name |
E******** R********
|
||||
1 2 | Physical Address |
Industriestrasse 1a
|
||||
1 2 |
Weilburg-Waldhausen
|
|||||
1 2 |
Germany
|
|||||
1 2 | Telephone Number |
49 64********
|
||||
1 2 | Fax Number |
49 64********
|
||||
1 2 |
e******@feig.de
|
|||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 2 | Yes | |||||
1 2 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 03/30/2017 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID Reader | ||||
1 2 | RF Reader | |||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Class II Permissive Change | ||||
1 2 | Original Equipment | |||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | C2PC: antenna expansion to include the PAD240/180-B and PAD74-U antennas. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
TUEV NORD Hochfrequenztechnik GmbH & Co. KG
|
||||
1 2 |
CTC advanced GmbH (former CETECOM ICT Services )
|
|||||
1 2 | Name |
R**** T********
|
||||
1 2 |
G**** S****
|
|||||
1 2 | Telephone Number |
+49 2********
|
||||
1 2 |
49-68********
|
|||||
1 2 | Fax Number |
+49 2********
|
||||
1 2 |
49-68********
|
|||||
1 2 |
r******@tuev-nord.de
|
|||||
1 2 |
t******@ctcadvanced.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 13.56000000 | 13.56000000 | |||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC