OBID i-scan MONTAGE INSTALLATION ID ISC.LRMU1000 ID ISC.LRU1000-M
(deutsch / english) public (B) 2004-12-07 M41200-0de-ID-B.doc H C S T U E D H S I L G N E OBID i-scan Montage / Installation ID ISC.LR(M)U1000 deutsche Version ab Seite 3 english version from page 28 FEIG ELECTRONIC GmbH Seite 2 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D Hinweis Copyright 2004 by FEIG ELECTRONIC GmbH Lange Strae 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de Alle frheren Ausgaben verlieren mit dieser Ausgabe ihre Gltigkeit. Die Angaben in diesem Dokument knnen ohne vorherige Ankndigung gendert werden. Weitergabe sowie Vervielfltigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte fr den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten. Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung fr die Richtigkeit und Vollstndigkeit der An-
gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht fr Folgeschden auf Grund fehlerhafter oder unvollstndiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bem-
hungen nie vollstndig vermeiden lassen, sind wir fr Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von gnstigsten Rahmenbedingun-
gen aus. FEIG ELECTRONIC GmbH bernimmt keine Gewhr fr die einwandfreie Funktion in systemfrem-
den Umgebungen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung dafr, dass die in diesem Dokument enthal-
tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte. OBID und OBID i-scan ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH FEIG ELECTRONIC GmbH Seite 3 von 52 M41200-0de-ID-B.doc H C S T U E D OBID i-scan Montage / Installation ID ISC.LR(M)U1000 Inhalt 1 2 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Leistungsmerkmale der Readerfamilie ID ISC.LR(M)U1000 6 7 2.1 2.2 2.3 2.4 2.5 2.6 Leistungsmerkmale.......................................................................................................7 Verfgbare Readertypen...............................................................................................7 Montage..........................................................................................................................8 Anschlussklemmen.......................................................................................................9 Antennenanschluss ....................................................................................................10 Versorgungsspannung ...............................................................................................10 2.7 Eingnge / Ausgnge..................................................................................................11 2.7.1 Optokoppler...................................................................................................................11 2.7.2 Relais ............................................................................................................................13 2.7.3 Readersynchronisation..................................................................................................14 2.8 Anschluss externer Diagnose-LEDs..........................................................................15 2.9 Schnittstellen...............................................................................................................16 2.9.1 RS232-Schnittstelle.......................................................................................................16 2.9.2 RS485/RS422 Schnittstelle ...........................................................................................17 2.9.3 Netzwerkanschluss .......................................................................................................18 2.9.3.1 LAN (nur Gertevarianten mit ACC)..............................................................18 2.9.4 CompactFlash-Steckplatz (nur Gertevarianten mit ACC)..........................................18 3 Bedien- und Anzeigeelemente 19 3.1 3.2 LEDs .............................................................................................................................19 Taster / Schalter ..........................................................................................................20 4 Inbetriebnahme 21 4.1 Schnittstellenkonfiguration........................................................................................21 4.1.1 RS485/RS422 ...............................................................................................................21 4.1.1.1 Adresseinstellung RS485/RS422x fr Busbetrieb ...........................................23 FEIG ELECTRONIC GmbH Seite 4 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 4.1.2 Netzwerkanschluss - LAN .............................................................................................23 5 Funkzulassungen 24 5.1 5.2 Europa (CE)..................................................................................................................24 USA (FCC) ....................................................................................................................24 6 Technische Daten 25 H C S T U E D FEIG ELECTRONIC GmbH Seite 5 von 52 M41200-0de-ID-B.doc C S T U E D OBID i-scan Montage / Installation ID ISC.LR(M)U1000 H 1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Das Gert darf nur fr den vom Hersteller vorgesehenen Zweck verwendet werden. Beim Aufstellen des Gertes im Geltungsbereich der FCC 47 CFR Part 15 ist ein Mindestab-
stand von 23cm zwischen Antenne und menschlichem Krper zu gewhrleisten. Die Bedienungsanleitung ist zugriffsfhig aufzubewahren und jedem Benutzer auszuhndigen. Unzulssige Vernderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen, die nicht vom Hersteller des Gertes verkauft oder empfohlen werden, knnen Brnde, elektri-
sche Schlge und Verletzungen verursachen. Solche Manahmen fhren daher zu einem Ausschluss der Haftung und der Hersteller bernimmt keine Gewhrleistung. Fr das Gert gelten die Gewhrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs gltigen Fassung. Fr eine ungeeignete, falsche manuelle oder automatische Ein-
stellung von Parametern fr ein Gert bzw. ungeeignete Verwendung eines Gertes wird kei-
ne Haftung bernommen. Reparaturen drfen nur vom Hersteller durchgefhrt werden. Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gert drfen nur von E-
lektrofachkrften mit einschlgiger Ausbildung erfolgen. Alle Arbeiten am Gert und dessen Aufstellung mssen in bereinstimmung mit den nationa-
len elektrischen Bestimmungen und den rtlichen Vorschriften durchgefhrt werden. Beim Arbeiten an dem Gert mssen die jeweils gltigen Sicherheitsvorschriften beachtet werden. FEIG ELECTRONIC GmbH Seite 6 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D 2 Leistungsmerkmale der Readerfamilie ID ISC.LR(M)U1000 2.1 Leistungsmerkmale Der Reader ist fr das Lesen von passiven Datentrgern, sogenannten Smart Labels, mit einer Betriebsfrequenz im UHF Bereich entwickelt. 2.2 Verfgbare Readertypen Folgende Readermodule sind z.Z. verfgbar:
Readermodultyp ID ISC.LRMU1000-A-EU ID ISC.LRU1000-M-A-EU ID ISC.LRMU1000-A-FCC ID ISC.LRU1000-M-A-FCC Tabelle 2-1: Readermodultypen Beschreibung Gertevariante ohne ACC fr Europa Gertevariante mit ACC fr Europa Gertevariante ohne ACC fr USA Gertevariante mit ACC fr USA FEIG ELECTRONIC GmbH Seite 7 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 H 2.3 Montage C S T U E D Zur Befestigung des Readers befinden sich auf der Montageplatte (schraffiert) vier Durchbrche. 3,6 5,5 5 3
, 0 7 1 210 Bild 2-1: Reader mit Montageplatte FEIG ELECTRONIC GmbH Seite 8 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D 2.4 Anschlussklemmen V1 V2 V3 V4 V5 V6 X14 T1 S1 T2 GND X13 VDC X20 RF-
Cont. J20 X12 X11 C C A 1 J 2 J 2 1
....J D N G
A
B
Y
Z
C O
E O
N
N I I D N G
A
B
Y
Z D N G D x R D x T NO X9 COM X5 X6 X7 X8 X1 X2 X3 X4 Bild 2-2: Anschlussklemmen des Readers FEIG ELECTRONIC GmbH Seite 9 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 H 2.5 Antennenanschluss C S T U E D Der Anschluss der externen Antennen befindet sich auf der analogen Leiterplatte. Das maximale Anzugsdrehmoment der SMA-Buchsen betrgt 0,45 Nm. Achtung:
Hhere Anzugsdrehmomente fhren zur Zerstrung des Steckers. Klemme Beschreibung X1, X2 X3, X4 Anschluss der externen Antennen
(Eingangsimpedanz 50) Tabelle 2-2: Anschluss der externen Antenne 2.6 Versorgungsspannung Die Versorgungsspannung von 15 bis 24 VDC ist an der Klemme X13 anzuschlieen. Klemme Kurzzeichen Beschreibung X13 / Pin 1 X13 / Pin 2 VDC GND Vcc - Versorgungsspannung Ground Versorgungsspannung Tabelle 2-3: Pinbelegung Versorgungsspannung GND VDC 12 X13 ID ISC.LRU1000 Bild 2-3: Anschluss der Versorgungsspannung Hinweis:
Eine Verpolung der Versorgungsspannung kann zur Zerstrung des Gertes fhren. FEIG ELECTRONIC GmbH Seite 10 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D 2.7 Eingnge / Ausgnge 2.7.1 Optokoppler Die Optokoppler an Klemmleiste X6 sind galvanisch von der Reader-Elektronik getrennt und ms-
sen daher mit einer externen Spannung versorgt werden. Klemme Kurzzeichen Beschreibung 1 2 3 4 O-C O-E IN+
IN-
Kollektor Ausgang 1 Emitter Ausgang 1
+ Eingang 1
- Eingang 1 Tabelle 2-4: Pinbelegung Optokoppler ID ISC.LRU1000 X6 Rint IN-
IN+
O-E O-C Rext Uext. Uext. Bild 2-4: Interne und mgliche externe Beschaltung der Optokoppler FEIG ELECTRONIC GmbH Seite 11 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 Der Transistoranschlu, Kollektor und Emitter, des Optokopplerausgangs ist von der Reader-
Elektronik galvanisch getrennt und ohne interne Zusatzbeschaltung an Klemme X6 nach auen gefhrt. Der Ausgang mu daher mit einer externen Spannung betrieben werden. H Optokopplerausgang (X6/1-2):
C S T U E D Hinweise:
Der Ausgang ist fr max. 24 V DC / 30 mA ausgelegt. Verpolung oder berlastung des Ausgangs fhrt zu dessen Zerstrung. Der Ausgang ist nur zum Schalten ohmscher Lasten vorgesehen. Optokopplereingang (X6/3-4):
Die Eingangs-LED des Optokopplers ist intern mit einem Serienwiderstand von 500 beschaltet. Bei Versorgungsspannungen grer 10V muss der Eingangsstrom durch einen weiteren externen Vorwiderstand (siehe Tabelle 3.4-1) auf max. 20 mA begrenzt werden. Tabelle 2-5 zeigt die bentigten externen Vorwiderstande bei den verschiedenen externen Span-
nungen Uext. Externe Spannung Uext Bentigter externer Vorwiderstand Rext 5 V ... 10 V 11 V ... 15 V 16 V ... 20 V 21 V ... 24 V
270 560 820 Tabelle 2-5: Bentigter externer Vorwiderstand Rext Hinweise:
Der Eingang ist fr eine maximale Eingangsspannung von 24 V DC und einem Ein-
gangsstrom von maximal 20 mA ausgelegt. Verpolung oder berlastung des Eingangs fhrt zu dessen Zerstrung. FEIG ELECTRONIC GmbH Seite 12 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 2.7.2 Relais Als Relaisausgang steht ein Wechsler zur Verfgung. Klemme Kurzzeichen Beschreibung 1 COM Arbeitskontakt 2 3 ffner Schlieer Tabelle 2-6: Pinbelegung Relaisausgang NC NO H C S T U E D Hinweise:
Der Relaisausgang ist fr max. 24 V DC / 2 A ausgelegt. Der Relaisausgang ist nur zum Schalten ohmscher Lasten vorgesehen. Im Falle einer induktiven Last sind die Relaiskontakte durch eine externe Schutzbeschaltung zu scht-
zen. ext.U X9 3 2 1 O N C N M O C ID ISC.LRU1000 Bild 2-5: Interne und mgliche externe Beschaltung des Relaisausgangs FEIG ELECTRONIC GmbH Seite 13 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 H 2.7.3 Readersynchronisation C S T U E D Mit der Readersynchronisation knnen verschiedene Aktionen der Reader synchronisiert werden. Klemme Kurzzeichen Beschreibung 1 2 3 4 5 GND GND A-
B+
Y-
Z+
- Eingang
+ Eingang
- Ausgang
+Ausgang Tabelle 2-7: Pinbelegung Readersynchronisation ID ISC.LRU1000 X5 5 4 3 2 1 OUT+ (Z) OUT- (Y) IN+ (B) IN- (A) GND Bild 2-6: Eingang und Ausgang der Synchronisation FEIG ELECTRONIC GmbH Seite 14 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D 2.8 Anschluss externer Diagnose-LEDs X14 ermglicht den Anschluss zustzlicher externer LEDs parallel zu den internen Diagnose-
LEDs. Der Anschluss der externen LEDs erfolgt gem Bild 3.7-1. Klemme Kurzzeichen Beschreibung 1 2 3 4 5 6 V1 Anode ext. V2 Anode ext. V3 Anode ext. V4 Anode ext. V5 Anode ext. GND Funktion entspricht interner LED V1 Funktion entspricht interner LED V2 Funktion entspricht interner LED V3 Funktion entspricht interner LED V4 Funktion entspricht interner LED V5 Gemeinsamer GND-Anschluss Tabelle 2-8: Pinbelegung externe LEDs Externe LEDs V1 V2 V3 V4 V5 X14 1 2 3 4 5 6 X14 642 1 3 5 ID ISC.LRU1000 Bild 3.7-1: Anschluss externer LEDs an X14 Hinweis:
Die Ausgnge an X14 sind nur zum Schalten einer externen LED vorgesehen. berlas-
tung der Ausgnge durch andere Lasten kann zu deren Zerstrung fhren. FEIG ELECTRONIC GmbH Seite 15 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 H 2.9 Schnittstellen C S T U E D 2.9.1 RS232-Schnittstelle Der Anschluss der RS232-Schnittstelle erfolgt ber X8. Die bertragungsparameter knnen per Softwareprotokoll konfiguriert werden. Anschlussbelegung X8 (RS232-Schnittstelle):
Klemme Kurzzeichen Beschreibung 1 2 3 GND RxD TxD RS232 GND RS232 - RxD RS232 - TxD Tabelle 2-9: Pinbelegung RS232-Schnittstelle ID ISC.LRU1000 9-pol. DUB-D-Buchse X6 3 2 1 TxD RxD GND PC Pin 5 Pin 3 Pin 2
X6 / 1 X6 / 2 X6 / 3 Bild 2-7: Verdrahtungsbeispiel fr den Anschluss der RS232-Schnittstelle FEIG ELECTRONIC GmbH Seite 16 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D 2.9.2 RS485/RS422 Schnittstelle Die zweite asynchrone Schnittstelle kann als RS485 oder RS422 konfiguriert werden (siehe Ab-
schnitt 5.1: Schnittstellenkonfiguration mittels Jumper). Der Anschluss der RS4xx-Schnittstelle erfolgt ber X7. Anschlussbelegung X7 (RS485/RS422-Schnittstelle):
Klemme Kurzzeichen Beschreibung 1 2 3 4 5 GND RS485/RS422 GND A-
B+
Y-
Z+
RS485/RS422 (A -) RS485/RS422 (B +) RS422 (Y -) RS422 (Z +) Tabelle 2-10: Pinbelegung RS485/RS422-Schnittstelle ID ISC.LRU1000 RS422 - (Z+) RS422 - (Y-) RS485/RS422 - (B+) RS485/RS422 - (A-) RS485/RS422 - GND X7 5 4 3 2 1 Bild 2-8: Anschlussbelegung der RS485/RS422-Schnittstelle FEIG ELECTRONIC GmbH Seite 17 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 H 2.9.3 Netzwerkanschluss C S T U E D 2.9.3.1 LAN (nur Gertevarianten mit ACC) Der Reader verfgt ber einen Integrierten 10/100Tbase Netzwerkschnittstelle mit RJ-45-
Anschlu. Der Anschluss erfolgt ber X11. Bei einer strukturierten Verkabelung sollte Kabel der Kategorie 5 verwendet werden. Dies garan-
tiert einen problemlosen Betrieb bei 10Mbps oder 100Mbps. Anschlussbelegung X8 (Netzwerk-Schnittstelle):
Klemme Kurzzeichen Beschreibung 1 2 3 4 5 6 7 8 TX+
TX-
RX+
VETH+
VETH+
RX-
VETH-
VETH-
Transmit Data +
Transmit Data -
Receive Data +
n.c. n.c. Receive Data -
n.c. n.c. Tabelle 2-11: Pinbelegung Ethernet-Schnittstelle 2.9.4 CompactFlash-Steckplatz (nur Gertevarianten mit ACC) Der Reader verfgt ber einen CF2-Steckplatz (Stecker X12). Dieser Steckplatz fr zuknftige Erweiterungsmglichkeiten durch CompactFlash-Karten vorgesehen. FEIG ELECTRONIC GmbH Seite 18 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D 3 Bedien- und Anzeigeelemente 3.1 LEDs Tabelle 3-1 zeigt die Konfiguration der LED. Kurzzeichen LED V1 (grn) LED V2 (blau) LED V3 (gelb) LED V4 (gelb) LED V5 (rot) Beschreibung
"RUN-LED 1"
- Signalisiert den ordnungsgemen Ablauf der internen Reader-Software (DSP) Diagnose 1: RF-Kommunikation / EEPROM-Status
- Signalisiert durch ein kurzes Blinken die fehlerfreie Kommuni-
kation mit einem Transponder auf der RF-Schnittstelle
- Blinkt abwechselnd mit V1 nach dem Reset im Anschlu an ein Software-Update
- Blinkt abwechselnd mit V1 falls nach einem Reset ein Daten-
fehler beim Lesen der Parameter auftrat Diagnose 2: Host-Kommunikation
- Signalisiert durch ein kurzes Blinken das Senden eines Proto-
kolls an den Host auf der RS232/RS485-Schnittstelle Reserviert Diagnose 4: RF-Warnung
- Leuchtet whrend der Reader-Initialisierung nach dem Ein-
schalten bzw. nach einem Reset.
- Leuchtet bei einem Fehler im RF-Teil des Readers. Der Feh-
lertyp kann per Software ber die RS232/RS485-Schnittstelle ausgelesen werden LED V6 (grn)
(Nur ID ISC.LRU1000-G)
"RUN-LED 2"
- Signalisiert den ordnungsgemen Ablauf des Controllers Tabelle 3-1: Konfiguration der LED FEIG ELECTRONIC GmbH Seite 19 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 H 3.2 Taster / Schalter C S T U E D Kurzzeichen Beschreibung T1 T2 S1 Reset-Taster RF Controller Reset-Taster ACC Reserviert
- T1: Durch bettigen von T1 wird am RF-Controller ein Reset durchgefhrt
- T2: Durch bettigen von T2 wird am ACC ein Reset durchgefhrt FEIG ELECTRONIC GmbH Seite 20 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 4 Inbetriebnahme 4.1 Schnittstellenkonfiguration 4.1.1 RS485/RS422 H C S T U E D ber die Jumper J7 J8 kann die asynchrone Schnittstelle als RS485- oder RS422-Schnittstelle konfiguriert werden. Jumper RS485 J7 J8 Geschlossen Geschlossen RS422 offen offen Tabelle 4-1: Konfiguration der RS485/RS422-Schnitstelle Es knnen die eventuell bentigten Abschlusswiderstnde mit den Jumpern J1 bis J6 zugeschaltet werden. Jumper Geschlossen offen J1 J2 J5 J3 J4 J6 Pull-Up an RS4xx - B ohne Pull-Up an RS4xx - B Pull-Down an RS4xx - A ohne Pull-Down an RS4xx A Abschlusswiderstand RS4xx - A RS4xx - B Pull-Up an RS422 - Z ohne Abschlusswiderstand RS485 - A RS485 - B ohne Pull-Up an RS422 - Z Pull-Down an RS422 - Y ohne Pull-Down an RS422 Y Abschlusswiderstand RS422 - Y RS422 - Z ohne Abschlusswiderstand RS422 - Y RS422 - Z Tabelle 4-2: Abschlusswiderstnde der RS485/RS422 FEIG ELECTRONIC GmbH Seite 21 von 52 M41200-0de-ID-B.doc H C S T U E D OBID i-scan Montage / Installation ID ISC.LR(M)U1000 500 Ohm J1 J8 J7 500 Ohm 120 Ohm J5 J2 RS485 +
RS485 -
J3 500 J1 500 J6 120 J5 J4 500 120 J2 500 RS422 Z+
RS422 Y-
RS422 B+
RS422 A-
Bild 4-1: Jumper der RS485-Schnittstelle Bild 4-2: Jumper der RS422-Schnittstelle J12
. J1 Bild 4-3: Jumper der RS485/RS422-Schnittstelle Tabelle 4-3 zeigt die Standardkonfiguration der Jumper J9 bis J12. Diese sind fr die RS485 und RS422 identisch. Jumper LRU1000-G J9 J10 J11 J12 geschlossen geschlossen offen offen LRU1000-M offen geschlossen offen geschlossen Tabelle 4-3: Standardkonfiguration der RS485/RS422 FEIG ELECTRONIC GmbH Seite 22 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D 4.1.1.1 Adresseinstellung RS485/RS422x fr Busbetrieb Fr den Busbetrieb bietet der Reader die Mglichkeit die bentigte Busadresse per Software zu vergeben. Die Adressvergabe erfolgt ber den Host-Rechner. Mit Hilfe der Software knnen dem Reader die Adressen "0" bis "254" zugewiesen werden. Hinweis:
Da alle Reader werksseitig die Adresse 0 eingestellt haben, mssen sie nacheinander ange-
schlossen und konfiguriert werden. 4.1.2 Netzwerkanschluss - LAN Vorraussetzung fr den Einsatz des TCP/IP-Protokolls ist, dass jedes Gert am Netzwerk ber eine eigene IP-Adresse verfgt. Alle Reader verfgen ber eine werksseitig voreingestellte IP-
Adresse. Die Reader mssen nacheinander ans Netzwerk angeschlossen und konfiguriert werden. Tabelle 3-1 zeigt die Standardkonfiguration des Netzwerkanschlusses. Netzwerk Adresse IP-Adresse Subnet-Mask Port 192.168.10.10 255.255.255.0 10001 Tabelle 4-4: Standardkonfiguration des Netzwerkanschlusses FEIG ELECTRONIC GmbH Seite 23 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 H 5 Funkzulassungen C S T U E D 5.1 Europa (CE) Die Funkanlage entspricht, bei bestimmungsgemer Verwendung den grundlegenden Anforde-
rungen des Artikels 3 und den brigen einschlgigen Bestimmungen der R&TTE Richtlinie 1999/5/E6 vom Mrz 99. Bei Betrieb im Band I nach ERC/REC 70-03 Annex 1 (869,400MHz 869,650MHz) gelten folgen-
de Einschrnkungen fr Bulgaria Italy Slovak Republic not implemented max 25 mW e.r.p. max 10 mW e.r.p. 5.2 USA (FCC) FCC ID: PJMLRU1000 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communica-
tions Commission Rules permitting the operation of this device. Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. FEIG ELECTRONIC GmbH Seite 24 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D 6 Technische Daten Mechanische Daten Abmessungen ( B x H x T ) 210 x 170 x 50 mm3 Gewicht ca. 0,8 kg Elektrische Daten Spannungsversorgung Leistungsaufnahme Betriebsfrequenz Sendeleistung Modulationsgrad Empfnger Antennenanschlsse 4 x gemultiplext Ausgnge:
- 1 Optokoppler
- 1 Differenzausgang
- 1 Relais ( 1 x Wechsler) Eingnge
- 1 Optokoppler
- 1 Differenzeingang Schnittstellen 15 V DC bis 24 V DC 5 %
Noise Ripple : max. 150 mV max. 30 VA 869,525 MHz (EN 300 220) 865,6 867,6MHz (EN 302 208) 902-928MHz (FCC CFR 47 Part 15.247) 100 mW 3 W (100 mW Step Software) 4 W EIRP (FCC CFR 47 Part 15.247) 2 W ERP (EN 302 208) 0,5Watt ERP (EN 300 220) 20% - 40% und 100%
(per Software einstellbar) Datenraten 40 320 kbps 4 x SMA Buchse (50) 24 V DC / 30 mA (galvanisch getrennt) Reader Synchronisation 24 V DC / 2 A max. 24 V DC/ 20 mA Reader Synchronisation
- RS232
- RS484 / RS422 (wahlweise einstellbar)
- Ethernet (TCP/IP) (Nur Gertevariante mit ACC) FEIG ELECTRONIC GmbH Seite 25 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LR(M)U1000 Protokoll Modi
- FEIG ISO Host
- Buffer Reader Mode (Data Filtering and buffe-
ring) Untersttzte Transponder
H C S T U E D 18000-A 18000-B (U-Code )
- EPC class 1
- EPC Generation 2
- EM4222 6 LEDs zur Diagnose des Betriebszustandes Synchronisation der Luftprotokolle durch Ver-
wendung der Reader Synchronisation
-25C bis +60C
-25C bis +85C EN60068-2-6 10 Hz bis 150 Hz : 0,075 mm / 1 g EN60068-2-27 Beschleunigung : 30 g EN 302 208 EN 300 220 FCC 47 CFR Part 15 EN 301 489 EN 60950 EN 50364 Signalgeber optisch Multi-Reader-Betrieb Umgebungsbedingungen Temperaturbereich
- Betrieb
- Lagerung Vibration Schock Angewendete Normen Zulassung Funk
- Europa
- USA EMV Sicherheit
- Niederspannung
- Human Exposure FEIG ELECTRONIC GmbH Seite 26 von 52 M41200-0de-ID-B.doc OBID i-scan Montage / Installation ID ISC.LRU1000 H C S T U E D FEIG ELECTRONIC GmbH Seite 27 von 52 M41200-0de-ID-B.doc H S I L G N E OBID i-scan Installation Note ID ISC.LRU1000 Copyright 2004 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH. FEIG ELECTRONIC GmbH Page 28 of 52 M41200-0de-ID-B.doc OBID i-scan Installation Contents ID ISC.LRU1000 1 2 Safety Instructions / Warning - Read before start-up !
Performance Features of Reader Family ID ISC.LRU1000 31 32 H S I L G N E 2.1 2.2 2.3 2.4 2.5 2.6 Performance features..................................................................................................32 Available Reader types ...............................................................................................32 Installation ...................................................................................................................33 Terminals .....................................................................................................................34 Antenna connection....................................................................................................35 Supply voltage.............................................................................................................36 2.7 Inputs / Outputs...........................................................................................................37 2.7.1 Optocouplers .................................................................................................................37 2.7.2 Relay .............................................................................................................................39 2.7.3 Reader synchronization.................................................................................................40 2.8 External diagnostic LED connections.......................................................................41 2.9 Interfaces .....................................................................................................................42 2.9.1 RS232 interface.............................................................................................................42 2.9.2 RS485/RS422 interface.................................................................................................43 2.9.3 Network connection.......................................................................................................44 2.9.4 CompactFlash Slot (only device version with ACC) ...................................................44 3 Operating and Display Elements 45 3.1 3.2 LEDs .............................................................................................................................45 Buttons / Switches ......................................................................................................46 4 Startup 47 4.1 Interface configuration................................................................................................47 4.1.1 RS485/RS422 ...............................................................................................................47 4.1.2 Network connection - LAN.............................................................................................49 FEIG ELECTRONIC GmbH Page 29 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 5 Radio Approvals 50 5.1 5.2 Europe (CE)..................................................................................................................50 USA (FCC) ....................................................................................................................50 6 Technical Data H S 51 I L G N E FEIG ELECTRONIC GmbH Page 30 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 1 Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer. When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation of 23cm between antenna and the human body must be maintained. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. H S I L G N E FEIG ELECTRONIC GmbH Page 31 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 2 Performance Features of Reader Family ID ISC.LRU1000 2.1 Performance features The Reader has been developed for reading passive data carriers, so-called Smart Labels, using an operating frequency in the UHF range. H S I L G N E 2.2 Available Reader types The following Readers are currently available:
Reader type ID ISC.LRMU1000-A-EU ID ISC.LRU1000-M-A-EU ID ISC.LRMU1000-A-FCC ID ISC.LRU1000-M-A-FCC Table 2-1: Reader types Description Device version without ACC for Europe Device version with ACC for Europe Device version without ACC for USA Device version with ACC for USA FEIG ELECTRONIC GmbH Page 32 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 2.3 Installation To mount the reader there are four drilled holes in the mounting plate (hatched). 3,6 5,5 5 3
, H S I L G N E 0 7 1 210 Fig. 2-1: Reader witch mounting plate FEIG ELECTRONIC GmbH Page 33 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 2.4 Terminals H S I L G N E V1 V2 V3 V4 V5 V6 X14 T1 S1 T2 GND X13 VDC X20 RF-
Cont. J20 X12 X11 C C A 1 J 2 J 2 1
....J NO X9 COM D N G
A
B
Y
Z
C O
E O
N
N I I D N G
A
B
Y
Z D N G D x R D x T X5 X6 X7 X8 X1 X2 X3 X4 Fig. 2-2: Reader terminals FEIG ELECTRONIC GmbH Page 34 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 2.5 Antenna connection The external antenna is connected on the analog circuit board. The maximum tightening torque for the SMA sockets is 0.45 Nm. Caution:
Greater tightening torques will destroy the plug. Terminal Description X1, X2 X3, X4 Connection for external antennas
(input impedance 50) Table 2-2: External antenna connection H S I L G N E FEIG ELECTRONIC GmbH Page 35 of 52 M41200-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU1000 2.6 Supply voltage The supply voltage of 15 to 24 VDC is connected to Terminal X13. Terminal Abbreviation Description X13 / Pin 1 X13 / Pin 2 VDC GND Vcc supply voltage Ground supply voltage Table 2-3: Pinouts for supply voltage GND VDC 12 X13 ID ISC.LRU1000 Fig. 2-3: Connecting the supply voltage Note:
Reversing the supply voltage polarity may destroy the device. FEIG ELECTRONIC GmbH Page 36 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 2.7 Inputs / Outputs 2.7.1 Optocouplers The optocouplers on Terminal X6 are galvanically isolated from the Reader electronics and must therefore be externally supplied. H S I L G N E Terminal Abbreviation Description 1 2 3 4 O-C O-E IN+
IN-
Collector Output 1 Emitter Output 1
+ Input 1
- Input 1 Table 2-4: Optocoupler pinouts ID ISC.LRU1000 X6 Rint IN-
IN+
O-E O-C Rext Uext. Uext. Fig. 2-4: Internal and possible external wiring of the optocouplers FEIG ELECTRONIC GmbH Page 37 of 52 M41200-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU1000 Optocoupler output (X6/1-2):
The transistor connections, collector and emitter, of the optocoupler output are galvanically isolated from the Reader electronics and are carried to the outside without any internal ancillary circuitry on Terminal X6. The output must therefore be powered by an external power supply. Note:
The output is configured for max. 24 V DC / 30 mA. Polarity reversal or overload on the output will destroy it. The output is intended for switching resistive loads only. Optocoupler input (X6/3-4):
The input LED associated with the optocoupler is connected internally to a series resistor of 500 . For supply voltages of greater than 10V the input current must be limited to max. 20 mA by means of an additional series resistor (see Table 3.4-1). Tabelle 2-5 shows the necessary external resistors for various external voltages Uext. External voltage Uext Required external series resistor Rext 5 V ... 10 V 11 V ... 15 V 16 V ... 20 V 21 V ... 24 V
270 560 820 Table 2-5: Required external series resistor Rext Notes:
The input is configured for a maximum input voltage of 24 V DC and an input current of max. 20 mA. Polarity reversal or overload on the input will destroy it. FEIG ELECTRONIC GmbH Page 38 of 52 M41200-0de-ID-B.doc OBID i-scan 2.7.2 Relay Installation ID ISC.LRU1000 H S I L G N E A relay output is provided in the form of a changeover relay. Terminal Abbreviation Description 1 2 3 COM Working contact NC NO Normally closed Normally open Table 2-6: Relay output pinouts Notes:
The relay output is configured for max. 24 V DC / 2 A. The relay output is intended for switching resistive loads only. If an inductive load is connected, the relay contacts must be protected by means of an external protection circuit. ext.U X9 3 2 1 O N C N M O C ID ISC.LRU1000 Fig. 2-5: Internal and possible external wiring of the relay output FEIG ELECTRONIC GmbH Page 39 of 52 M41200-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU1000 2.7.3 Reader synchronization Reader synchronization can be used to synchronize various Reader actions. Terminal Abbreviation Description 1 2 3 4 5 GND A-
B+
Y-
Z+
GND
- Input
+ Input
- Output
+ Output Table 2-7: Reader synchronization pinouts ID ISC.LRU1000 X5 5 4 3 2 1 OUT+ (Z) OUT- (Y) IN+ (B) IN- (A) GND Fig. 2-6: Synchronization input and output FEIG ELECTRONIC GmbH Page 40 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 2.8 External diagnostic LED connections X14 allows for connection of additional external LEDs in parallel with the internal diagnostic LEDs. The external LEDs are connected as shown in Fig. 3.7-1. H S I L G N E Terminal Abbreviation Description 1 2 3 4 5 6 V1 Anode ext. V2 Anode ext. V3 Anode ext. V4 Anode ext. V5 Anode ext. GND Function same as internal LED V1 Function same as internal LED V2 Function same as internal LED V3 Function same as internal LED V4 Function same as internal LED V5 Common GND Table 2-8: External LED pinouts Externe LEDs V1 V2 V3 V4 V5 X14 1 2 3 4 5 6 X14 642 1 3 5 ID ISC.LRU1000 Fig. 3.7-1: Connecting external LEDs to X14 Note:
The outputs on X14 are intended for switching an external LED only. Overloading the outputs with other loads may destroy them. FEIG ELECTRONIC GmbH Page 41 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 2.9 Interfaces 2.9.1 RS232 interface The RS232 interface is connected on X8. The transmission parameters can be configured by means of software protocol. H S I L G N E Pin configuration X8 (RS232 interface):
Terminal Abbreviation Description 1 2 3 GND RxD TxD RS232 GND RS232 - RxD RS232 - TxD Table 2-9: RS232 interface pinouts ID ISC.LRU1000 9-pol. DUB-D-Buchse X6 3 2 1 TxD RxD GND PC Pin 5 Pin 3 Pin 2
X6 / 1 X6 / 2 X6 / 3 Fig. 2-7: Wiring example for connecting the RS232 interface FEIG ELECTRONIC GmbH Page 42 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 2.9.2 RS485/RS422 interface The second asynchronous interface can be configured for RS485 or RS422 (see Section Interface configuration). The RS485/RS422 interface is connected on X7. Pin configuration X7 (RS485/RS422 interface):
Terminal Abbreviation Description 1 2 3 GND RS485/RS422 GND A-
B+
RS485/RS422 (A -) RS485/RS422 (B +) 4 5 RS422 (Y -) RS422 (Z +) Table 2-10: RS485/RS422 interface pinouts Y-
Z+
H S I L G N E ID ISC.LRU1000 RS422 - (Z+) RS422 - (Y-) RS485/RS422 - (B+) RS485/RS422 - (A-) RS485/RS422 - GND X7 5 4 3 2 1 Fig. 2-8: Wiring example for the RS485/RS422 interface FEIG ELECTRONIC GmbH Page 43 of 52 M41200-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU1000 2.9.3 Network connection 2.9.3.1 LAN (only device version with ACC) The Reader has an integrated 10/100Tbase network port for an RJ45. Connection is made on X11. With structured cabling Cat 5 cables should be used. This ensure reliable operation at 10Mbps or 100Mbps. Pin configuration for X8 (network interface):
Terminal Abbreviation Description 1 2 3 4 5 6 7 8 TX+
TX-
RX+
VETH+
VETH+
RX-
VETH-
VETH-
Transmit Data +
Transmit Data -
Receive Data +
n.c. n.c. Receive Data -
n.c. n.c. Table 2-11: Ethernet interface pinouts 2.9.4 CompactFlash Slot (only device version with ACC) The Reader has a CF2 slot (connector X12). This slot is for future use by CompactFlash cards. FEIG ELECTRONIC GmbH Page 44 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 3 Operating and Display Elements 3.1 LEDs Tabelle 3-1 shows the LED configuration. H S I L G N E Abbreviation LED V1 (green) LED V2 (blue) Description Indicates proper running of the internal Reader software (DSP)
"RUN-LED 1"
Diagnostic 1: RF communication / EEPROM status
- Short flashing indicates errorless communication with a transponder on the RF interface
- Flashes alternately with V1 after a reset following a software update
- Flashes alternately with V1 in case of a data error when reading the parameters after a reset LED V3 (yellow) Diagnostic 2: Host communication
- Short flashing indicates sending of a protocol to the host on the RS232/RS485 interface LED V4 (yellow) Reserved LED V5 (red) Diagnostic 4: RF warning
- Comes on during Reader initialization after power-on or after a reset.
- Comes on when there is an error in the RF section of the Reader. The error type can be read out via software over the RS232/RS485 interface LED V6 (green)
(ID ISC.LRU1000-
G only)
"RUN-LED 2"
Indicates proper running of the controller Table 3-1: LED configuration FEIG ELECTRONIC GmbH Page 45 of 52 M41200-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU1000 3.2 Buttons / Switches Abbreviation Description T1 T2 S1 RF Controller reset button ACC reset button Reserved
- T1: Pressing T1 resets the RF Controller
- T2: Pressing T2 resets the ACC FEIG ELECTRONIC GmbH Page 46 of 52 M41200-0de-ID-B.doc OBID i-scan 4 Startup 4.1 Interface configuration 4.1.1 RS485/RS422 Installation ID ISC.LRU1000 H S I L G N E Jumpers J7 J8 are used to configure the asynchronous interface as an RS485 or R422 port. Jumper J7 J8 RS485 closed closed RS422 open open Table 4-1: Configuration of the RS485/RS422 port Any termination resistors needed can be enabled using jumpers J1 through J6. Jumper Closed Open J1 J2 J5 J3 J4 J6 Pull-Up on RS4xx - B Pull-Down on RS4xx - A without Pull-Down on RS4xx A without Pull-Up on RS4xx - B Termination resistor without Termination resistor RS4xx - A RS4xx - B RS485 - A RS485 - B Pull-Up on RS422 - Z Pull-Down on RS422 - Y without Pull-Up on RS422 - Z without Pull-Down on RS422 Y Termination resistor without Termination resistor RS422 - Y RS422 - Z RS422 - Y RS422 - Z Table 4-2: Termination resistors for RS485/RS422 FEIG ELECTRONIC GmbH Page 47 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 500 Ohm J1 J8 J7 500 Ohm 120 Ohm J5 J2 RS485 +
RS485 -
J3 500 J1 500 J6 120 J5 J4 500 120 J2 500 RS422 Z+
RS422 Y-
RS422 B+
RS422 A-
H S I L G N E Fig. 4-1: RS485 interface jumpers Fig. 4-2: RS422 interface jumpers J12
. J1 Fig. 4-3: RS485/RS422 interface jumpers Tabelle 4-3 shows the standard configuration of jumpers J9 through J12. These are identical for RS485 and RS422. Jumper LRU1000-G LRU1000-M J9 J10 J11 J12 closed closed open open open closed open closed Table 4-3: Standard configuration for RS485/RS422 FEIG ELECTRONIC GmbH Page 48 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 H S I L G N E 4.1.1.1 Address assignment of RS485/RS422 for bus operation For bus operation the Reader can be assigned the required bus address via software. The address is assigned by the host computer. The software is used to assign addresses 0 through 254 to the Reader. Note:
Since all Readers are factory set with address 0, they must be connected and configured one after the other. 4.1.2 Network connection - LAN The prerequisite for using TCP/IP protocol is that each device have a unique address on the network. All Readers have a factory set IP address. The Readers must be connected and configured one after the other. Tabelle 3-1 shows the standard configuration of the network connection. Network Address IP address Subnet mask Port 192.168.10.10 255.255.255.0 10001 Table 4-4: Standard configuration of the network connection FEIG ELECTRONIC GmbH Page 49 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 5 Radio Approvals 5.1 Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. H S I L G N E For operation in Band I ERC/REC 70-03 Annex 1 (869,400MHz 869,650MHz) apply following restrictions in Bulgaria Italy Slovak Republic not implemented max 25 mW e.r.p. max 10 mW e.r.p. 5.2 USA (FCC) FCC ID: PJMLRU1000 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communica-
tions Commission Rules permitting the operation of this device. Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. FEIG ELECTRONIC GmbH Page 50 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 6 Technical Data Mechanical Data Dimensions ( W x H x D ) 210 x 170 x 50 mm3 Weight approx. 0,8 kg H S I L G N E Electrical Data Supply voltage Power consumption Operating frequency Transmitting power Modulation Receiver Antenna connections 4 x multiplexing Outputs:
- 1 optocoupler
- 1 differential output
- 1 relay ( 1 x changeover) Inputs
- 1 optocoupler
- 1 differential input Interfaces 15 V DC to 24 V DC 5 %
Noise Ripple : max. 150 mV max. 30 VA 869.525 MHz (EN 300 220) 865.6 867.6 MHz (EN 302 208) 902-928 MHz (FCC CFR 47 Part 15.247) 100 mW 3 W (100 mW Step Software) 4 W EIRP (FCC CFR 47 Part 15.247) 2 W ERP (EN 302 208) 0.5 W ERP (EN 300 220) 20% - 40% and 100%
(software configurable) Data rates 40 320 kbps 4 x SMA socket (50) 24 V DC / 30 mA (galvanically isolated) Reader synchronization 24 V DC / 2 A max. 24 V DC/ 20 mA Reader synchronization
- RS232
- RS484 / RS422 (selectable)
- Ethernet (TCP/IP) (only device version with ACC) FEIG ELECTRONIC GmbH Page 51 of 52 M41200-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU1000 Protocol modes
- FEIG ISO Host
- Buffer Reader Mode (Data Filtering and buffering) Supported transponders
H S I L G N E Optical indicators Multi-Reader operation Ambient Temperature range
- Operating
- Storage Vibration Shock Applicable standards RF approval
- Europe
- USA EMC Safety
- Low-Voltage
- Human Exposure 18000-A 18000-B (U-Code )
- EPC class 1
- EPC Generation 2
- EM4222 6 LEDs for operating status diagnostics Synchronization of the air protocols using Reader synchronization
-25C to +60C
-25C to +85C EN60068-2-6 10 Hz to 150 Hz :0.075 mm / 1 g EN60068-2-27 Acceleration
: 30 g EN 302 208 EN 300 220 FCC 47 CFR Part 15 EN 301 489 EN 60950 EN 50364 FEIG ELECTRONIC GmbH Page 52 of 52 M41200-0de-ID-B.doc
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2004-12-08 | 902.7 ~ 927.2 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2004-12-08
|
||||
1 | Applicant's complete, legal business name |
Feig Electronic GmbH
|
||||
1 | FCC Registration Number (FRN) |
0007634793
|
||||
1 | Physical Address |
Lange Strae 4
|
||||
1 |
Weilburg-Waldhausen, N/A D-35781
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
g******@ict.cetecom.de
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
PJM
|
||||
1 | Equipment Product Code |
LRU1000
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
E**** R********
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
+49 6********
|
||||
1 | Fax Number |
+49 6********
|
||||
1 |
e******@feig.de
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID Reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Limited Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power Output listed is conducted.Limited Modular Approval. Approval is limited to OEM installation only.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 23 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. OEM integrators and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Cetecom ICT Services GmbH
|
||||
1 | Name |
R**** H****
|
||||
1 | Telephone Number |
49-68********
|
||||
1 | Fax Number |
49-68********
|
||||
1 |
r******@ict.cetecom.de
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 902.70000000 | 927.20000000 | 0.9800000 |