OBID i-scan MONTAGE INSTALLATION ID ISC.LRU2000
(deutsch / english) final public (B) 2006-09-03 M60801-0de-ID-B.doc H C S T U E D H S I L G N E OBID i-scan Montage ID ISC.LRU2000 deutsche Version ab Seite 3 english version from page 30 FEIG ELECTRONIC GmbH Seite 2 von 56 M60801-0de-ID-B.doc OBID i-scan Montage Hinweis Copyright 2004 - 2006 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de ID ISC.LRU2000 H C S T U E D Alle frheren Ausgaben verlieren mit dieser Ausgabe ihre Gltigkeit. Die Angaben in diesem Dokument knnen ohne vorherige Ankndigung gendert werden. Weitergabe sowie Vervielfltigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte fr den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten. Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung fr die Richtigkeit und Vollstndigkeit der An-
gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht fr Folgeschden auf Grund fehlerhafter oder unvollstndiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bem-
hungen nie vollstndig vermeiden lassen, sind wir fr Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von gnstigsten Rahmenbedingun-
gen aus. FEIG ELECTRONIC GmbH bernimmt weder Gewhr fr die einwandfreie Funktion in system-
fremden Umgebungen, noch fr die Funktion eines Gesamtsystems, welches die in diesem Dokument be-
schriebenen Gerte enthlt. FEIG ELECTRONIC weist ausdrcklich darauf hin, dass die in diesem Dokument beschriebenen Gerte nicht fr den Einsatz mit oder in medizinischen Gerten oder fr Gerte fr lebenserhaltende Manahmen konzipiert sind, bei denen ein Fehler eine Gefahr fr menschliches Leben oder fr die gesundheitliche Un-
versehrtheit zur Folge haben kann. Der Applikationsdesigner ist dafr verantwortlich geeignete Manahmen zu ergreifen um Gefahren, Schden oder Verletzungen zu vermeiden. Gerte, die in diesem Dokument beschrieben werden drfen nicht im "Transport Markt" verkauft, benutz, geleast, angeboten oder anderweitig bertragen, exportiert und importiert werden. Als "Transport Markt" sind folgende Anwendungen definiert: (I) Elektronische Maut und Verkehrs Management (ETTM), (II) ffentliche Kraftfahrzeugzulassung, -Registrierung und -Kontrolle (III) Verfolgung von schienengebundenen Lokomoti-
ven und Wagons (IV) erdgebundene Managementsysteme fr Flughafen Transporte (GTMS) und Taxi Ab-
fertigung (V) kostenpflichtige Parksysteme und (VI) Fahrzeug initiierte mobile Bezahlsysteme, bei denen der RFID Transponder bereits bei Auslieferung montiert ist, aber nicht beim Fahrzeughersteller in das Fahrzeug integriert wurde. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung dafr, dass die in diesem Dokument enthal-
tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte. OBID und OBID i-scan ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH FEIG ELECTRONIC GmbH Seite 3 von 56 M60801-0de-ID-B.doc H C S T U E D OBID i-scan Montage Inhalt ID ISC.LRU2000 1 2 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Leistungsmerkmale der Readerfamilie ID ISC.LRU2000 6 7 2.1 2.2 Leistungsmerkmale.......................................................................................................7 Verfgbare Readertypen...............................................................................................7 2.3 Montage..........................................................................................................................8 2.3.1 Kabelverschraubungen ...................................................................................................9 2.3.2 ffnen des Deckels .......................................................................................................10 2.4 2.5 2.6 Anschlussklemmen.....................................................................................................11 Antennenanschluss ....................................................................................................12 Versorgungsspannung ...............................................................................................12 2.7 Eingnge / Ausgnge..................................................................................................13 2.7.1 Optokoppler...................................................................................................................13 2.7.2 Relais ............................................................................................................................15 2.7.3 Readersynchronisation..................................................................................................16 2.8 Anschluss externer Diagnose-LEDs..........................................................................17 2.9 Schnittstellen...............................................................................................................18 2.9.1 RS232-Schnittstelle.......................................................................................................18 2.9.2 RS485/RS422 Schnittstelle ...........................................................................................19 2.9.3 Netzwerkanschluss .......................................................................................................20 2.9.4 CompactFlash-Steckplatz (nur Gertevarianten mit ACC)..........................................20 3 Bedien- und Anzeigeelemente 21 3.1 3.2 LEDs .............................................................................................................................21 Taster / Schalter ..........................................................................................................22 4 Inbetriebnahme 23 4.1 Schnittstellenkonfiguration........................................................................................23 4.1.1 RS485/RS422 ...............................................................................................................23 FEIG ELECTRONIC GmbH Seite 4 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 4.1.2 Netzwerkanschluss - LAN .............................................................................................25 5 Funkzulassungen 26 5.1 5.2 Europa (CE)..................................................................................................................26 USA (FCC) ....................................................................................................................26 6 Technische Daten 27 H C S T U E D FEIG ELECTRONIC GmbH Seite 5 von 56 M60801-0de-ID-B.doc C S T U E D OBID i-scan Montage ID ISC.LRU2000 H 1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Das Gert darf nur fr den vom Hersteller vorgesehenen Zweck verwendet werden. Beim Aufstellen des Gertes im Geltungsbereich der FCC 47 CFR Part 15 ist ein Mindestab-
stand von 23cm zwischen Antenne und menschlichem Krper zu gewhrleisten. Die Bedienungsanleitung ist zugriffsfhig aufzubewahren und jedem Benutzer auszuhndigen. Unzulssige Vernderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen, die nicht vom Hersteller des Gertes verkauft oder empfohlen werden, knnen Brnde, elektri-
sche Schlge und Verletzungen verursachen. Solche Manahmen fhren daher zu einem Ausschluss der Haftung und der Hersteller bernimmt keine Gewhrleistung. Fr das Gert gelten die Gewhrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs gltigen Fassung. Fr eine ungeeignete, falsche manuelle oder automatische Ein-
stellung von Parametern fr ein Gert bzw. ungeeignete Verwendung eines Gertes wird keine Haftung bernommen. Reparaturen drfen nur vom Hersteller durchgefhrt werden. Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gert drfen nur von Elekt-
rofachkrften mit einschlgiger Ausbildung erfolgen. Alle Arbeiten am Gert und dessen Aufstellung mssen in bereinstimmung mit den nationa-
len elektrischen Bestimmungen und den rtlichen Vorschriften durchgefhrt werden. Beim Arbeiten an dem Gert mssen die jeweils gltigen Sicherheitsvorschriften beachtet wer-
den. Besonderer Hinweis fr Trger von Herzschrittmachern:
Obwohl dieses Gert die zulssigen Grenzwerte fr elektromagnetische Felder nicht ber-
schreitet, sollten Sie einen Mindestabstand von 25 cm zwischen dem Gert und Ihrem Herz-
schrittmacher einhalten und sich nicht fr lngere Zeit in unmittelbarer Nhe des Gerts bzw. der Antenne aufhalten. FEIG ELECTRONIC GmbH Seite 6 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H C S T U E D 2 Leistungsmerkmale der Readerfamilie ID ISC.LRU2000 2.1 Leistungsmerkmale Der Reader ist fr das Lesen von passiven Datentrgern, sogenannten Smart Labels, mit einer Betriebsfrequenz im UHF Bereich entwickelt. 2.2 Verfgbare Readertypen Folgende Reader und Readermodule sind z.Z. verfgbar:
Readertyp ID ISC.LRU2000-A-EU ID ISC.LRU2000-A-FCC ID ISC.LRU2000i-A-EU ID ISC.LRU2000i-A-FCC Tabelle 2-1: Readertypen Beschreibung Gertevariante mit ACC fr Europa Gertevariante mit ACC fr USA Gertevariante mit ACC und interner Antenne fr Europa Gertevariante mit ACC und interner Antenne fr USA Readermodultyp ID ISC.LRMU2000-B-EU ID ISC.LRMU2000-B-FCC Tabelle 2-2: Readermodultypen Beschreibung Gertevariante ohne ACC fr Europa Gertevariante ohne ACC fr USA FEIG ELECTRONIC GmbH Seite 7 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H 2.3 Montage C S T U E D Der Reader ist fr die Montage auf Wnden, auch im Freien, konzipiert. Zur Wandmontage befin-
den sich im Gehuse vorgesehene Lcher. 90 6 1 3
. 5 0 0 3 161 180 Bild 2-1: Montagezeichnung FEIG ELECTRONIC GmbH Seite 8 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H C S T U E D 2.3.1 Kabelverschraubungen An der Unterseite des Gehuses befinden sich die Kabelverschraubungen. Bild 2-2: Montage-
zeichnung zeigt die Anordnung und in Tabelle 2-3: Kabelverschraubungen ID ISC.LRU2000 ist dargestellt, welche Kabelverschraubungen fr die einzelnen Leitungen verwendet werden sollen. 6 7 1 2 3 8 4 9 5 Bild 2-2: Montagezeichnung Kabelver-
schraubung Gre Klemmbereich 1 2 3 4 5 6 7 8 9 M 16 M 16 M 16 M 16 M 12 M 16 M 16 M 12 M 25
[mm]
4.5 10 4.5 10 4.5 10 4.5 10 3.5 7 4.5 10 4.5 10 3.5 7 9 17 Beschreibung Anschlusskabel Antenne Anschlusskabel Antenne Anschlusskabel Antenne Anschlusskabel Antenne Spannungsversorgung Ein- / Ausgnge / Schnittstelle Ein- / Ausgnge / Schnittstelle Ein- / Ausgnge / Schnittstelle Netzwerkanschluss (optional) Tabelle 2-3: Kabelverschraubungen ID ISC.LRU2000 FEIG ELECTRONIC GmbH Seite 9 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H 2.3.2 ffnen des Deckels C S T U E D In Bild 2-3: ffnen des Deckels ist dargestellt wie sich das Gehuse ffnen lsst. Bild 2-3: ffnen des Deckels FEIG ELECTRONIC GmbH Seite 10 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 2.4 Anschlussklemmen H C S T U E D GND X13 VDC X12 J20 X11 X20 C C A V1 V2 V3 V4 V5 V6 X14 S1 T1 T2 D N G
A
B
Y
Z 1 J 2 J 2 1
....J
C O
E O
N
N I I D N G
A
B
Y
Z NO X9 COM D N G D x R D x T X5 X6 X7 X8 X1 X2 X3 X4 Bild 2-4: Anschlussklemmen des Readers FEIG ELECTRONIC GmbH Seite 11 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H 2.5 Antennenanschluss C S T U E D Der Anschluss der externen Antennen befindet sich auf der analogen Leiterplatte. Das maximale Anzugsdrehmoment der SMA-Buchsen betrgt 0,45 Nm. Achtung:
Hhere Anzugsdrehmomente fhren zur Zerstrung des Steckers. Klemme Beschreibung X1, X2 X3, X4 Anschluss der externen Antennen
(Eingangsimpedanz 50) Tabelle 2-4: Anschluss der externen Antenne 2.6 Versorgungsspannung Die Versorgungsspannung von 15 bis 24 VDC ist an der Klemme X13 anzuschlieen. Klemme Kurzzeichen Beschreibung X13 / Pin 1 X13 / Pin 2 VDC GND Vcc - Versorgungsspannung Ground Versorgungsspannung Tabelle 2-5: Pinbelegung Versorgungsspannung D N G C D V 2 1 X13 Bild 2-5: Anschluss der Versorgungsspannung Hinweis:
Eine Verpolung der Versorgungsspannung kann zur Zerstrung des Gertes fhren. FEIG ELECTRONIC GmbH Seite 12 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H C S T U E D 2.7 Eingnge / Ausgnge 2.7.1 Optokoppler Die Optokoppler an Klemmleiste X6 sind galvanisch von der Reader-Elektronik getrennt und ms-
sen daher mit einer externen Spannung versorgt werden. Klemme Kurzzeichen Beschreibung 1 2 3 4 O-C O-E IN+
IN-
Kollektor Ausgang 1 Emitter Ausgang 1
+ Eingang 1
- Eingang 1 Tabelle 2-6: Pinbelegung Optokoppler Rint X6 4 3 2 1 Rext IN-
IN+
O-E O-C Uext. Uext. Bild 2-6: Interne und mgliche externe Beschaltung der Optokoppler FEIG ELECTRONIC GmbH Seite 13 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 Der Transistoranschlu, Kollektor und Emitter, des Optokopplerausgangs ist von der Reader-
Elektronik galvanisch getrennt und ohne interne Zusatzbeschaltung an Klemme X6 nach auen gefhrt. Der Ausgang mu daher mit einer externen Spannung betrieben werden. H Optokopplerausgang (X6/1-2):
C S T U E D Hinweise:
Der Ausgang ist fr max. 24 V DC / 30 mA ausgelegt. Verpolung oder berlastung des Ausgangs fhrt zu dessen Zerstrung. Der Ausgang ist nur zum Schalten ohmscher Lasten vorgesehen. Optokopplereingang (X6/3-4):
Die Eingangs-LED des Optokopplers ist intern mit einem Serienwiderstand von 500 beschaltet. Bei Versorgungsspannungen grer 10V muss der Eingangsstrom durch einen weiteren externen Vorwiderstand (siehe Tabelle 2-7) auf max. 20 mA begrenzt werden. Tabelle 2-7 zeigt die bentigten externen Vorwiderstande bei den verschiedenen externen Span-
nungen Uext. Externe Spannung Uext Bentigter externer Vorwiderstand Rext 5 V ... 10 V 11 V ... 15 V 16 V ... 20 V 21 V ... 24 V
270 560 820 Tabelle 2-7: Bentigter externer Vorwiderstand Rext Hinweise:
Der Eingang ist fr eine maximale Eingangsspannung von 24 V DC und einem Ein-
gangsstrom von maximal 20 mA ausgelegt. Verpolung oder berlastung des Eingangs fhrt zu dessen Zerstrung. FEIG ELECTRONIC GmbH Seite 14 von 56 M60801-0de-ID-B.doc Montage ID ISC.LRU2000 H C S T U E D OBID i-scan 2.7.2 Relais Als Relaisausgang steht ein Wechsler zur Verfgung. Klemme Kurzzeichen Beschreibung 1 COM Arbeitskontakt 2 3 ffner Schlieer Tabelle 2-8: Pinbelegung Relaisausgang NC NO Hinweise:
Der Relaisausgang ist fr max. 24 V DC / 2 A ausgelegt. Der Relaisausgang ist nur zum Schalten ohmscher Lasten vorgesehen. Im Falle einer induktiven Last sind die Relaiskontakte durch eine externe Schutzbeschaltung zu scht-
zen. ext.U X9 3 2 1 O N C N M O C Bild 2-7: Interne und mgliche externe Beschaltung des Relaisausgangs FEIG ELECTRONIC GmbH Seite 15 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H 2.7.3 Readersynchronisation C S T U E D Mit der Readersynchronisation knnen verschiedene Aktionen der Reader synchronisiert werden. Klemme Kurzzeichen Beschreibung 1 2 3 4 5 GND GND A-
B+
Y-
Z+
- Eingang
+ Eingang
- Ausgang
+Ausgang Tabelle 2-9: Pinbelegung Readersynchronisation OUT+ (Z+) OUT- (Y-) IN+ (B+) IN- (A-) GND X5 5 4 3 2 1 Bild 2-8: Eingang und Ausgang der Synchronisation FEIG ELECTRONIC GmbH Seite 16 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H C S T U E D 2.8 Anschluss externer Diagnose-LEDs X14 ermglicht den Anschluss zustzlicher externer LEDs parallel zu den internen Diagnose-
LEDs. Der Anschluss der externen LEDs erfolgt gem Bild 2-9. Klemme Kurzzeichen Beschreibung 1 2 3 4 5 6 V1 Anode ext. V2 Anode ext. V3 Anode ext. V4 Anode ext. V5 Anode ext. GND Funktion entspricht interner LED V1 Funktion entspricht interner LED V2 Funktion entspricht interner LED V3 Funktion entspricht interner LED V4 Funktion entspricht interner LED V5 Gemeinsamer GND-Anschluss Tabelle 2-10: Pinbelegung externe LEDs ACC-Modul V5 V6 X14 S1 T1 X14 642 1 3 5 X14 1 2 3 4 5 6 V5 V4 V3 V2 V1 Externe LEDs Bild 2-9 Anschluss externer LEDs an X14 Hinweis:
Die Ausgnge an X14 sind nur zum Schalten einer externen LED vorgesehen. berlas-
tung der Ausgnge durch andere Lasten kann zu deren Zerstrung fhren. FEIG ELECTRONIC GmbH Seite 17 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H 2.9 Schnittstellen C S T U E D 2.9.1 RS232-Schnittstelle Der Anschluss der RS232-Schnittstelle erfolgt ber X8. Die bertragungsparameter knnen per Softwareprotokoll konfiguriert werden. Anschlussbelegung X8 (RS232-Schnittstelle):
Klemme Kurzzeichen Beschreibung 1 2 3 GND RxD TxD RS232 GND RS232 - RxD RS232 - TxD Tabelle 2-11: Pinbelegung RS232-Schnittstelle X8 3 2 1 TxD RxD GND 9-pol. D-SUB-Buchse PC X8 / 1 X8 / 2 X8 / 3
Pin 5 Pin 3 Pin 2 Bild 2-10: Verdrahtungsbeispiel fr den Anschluss der RS232-Schnittstelle FEIG ELECTRONIC GmbH Seite 18 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H C S T U E D 2.9.2 RS485/RS422 Schnittstelle Die zweite asynchrone Schnittstelle kann als RS485 oder RS422 konfiguriert werden (siehe Ab-
schnitt 4.1: Schnittstellenkonfiguration mittels Jumper). Der Anschluss der RS4xx-Schnittstelle erfolgt ber X7. Anschlussbelegung X7 (RS485/RS422-Schnittstelle):
Klemme Kurzzeichen Beschreibung 1 2 3 4 5 GND RS485/RS422 GND A-
B+
Y-
Z+
RS485/RS422 (A -) RS485/RS422 (B +) RS422 (Y -) RS422 (Z +) Tabelle 2-12: Pinbelegung RS485/RS422-Schnittstelle RS422 (Z+) RS422 (Y-) RS485/RS422 (B+) RS485/RS422 (A-) RS485/RS422 GND X7 5 4 3 2 1 Bild 2-11: Anschlussbelegung der RS485/RS422-Schnittstelle FEIG ELECTRONIC GmbH Seite 19 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H 2.9.3 Netzwerkanschluss C S T U E D 2.9.3.1 LAN (nur Gertevarianten mit ACC) Der Reader verfgt ber einen Integrierten 10/100Tbase Netzwerkschnittstelle mit RJ-45-
Anschlu. Der Anschluss erfolgt ber X11. Bei einer strukturierten Verkabelung sollte Kabel der Kategorie 5 verwendet werden. Dies garan-
tiert einen problemlosen Betrieb bei 10Mbps oder 100Mbps. Anschlussbelegung X8 (Netzwerk-Schnittstelle):
Klemme Kurzzeichen Beschreibung 1 2 3 4 5 6 7 8 TX+
TX-
RX+
VETH+
VETH+
RX-
VETH-
VETH-
Transmit Data +
Transmit Data -
Receive Data +
n.c. n.c. Receive Data -
n.c. n.c. Tabelle 2-13: Pinbelegung Ethernet-Schnittstelle 2.9.4 CompactFlash-Steckplatz (nur Gertevarianten mit ACC) Der Reader verfgt ber einen CF2-Steckplatz (Stecker X12). Dieser Steckplatz fr zuknftige Erweiterungsmglichkeiten durch CompactFlash-Karten vorgesehen. FEIG ELECTRONIC GmbH Seite 20 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H C S T U E D 3 Bedien- und Anzeigeelemente 3.1 LEDs Tabelle 3-1 zeigt die Konfiguration der LED. Kurzzeichen LED V1 (grn) LED V2 (blau) LED V3 (gelb) LED V4 (gelb) LED V5 (rot) Beschreibung
"RUN-LED 1"
- Signalisiert den ordnungsgemen Ablauf der internen Reader-Software (DSP) Diagnose 1: RF-Kommunikation / EEPROM-Status
- Signalisiert durch ein kurzes Blinken die fehlerfreie Kommuni-
kation mit einem Transponder auf der RF-Schnittstelle
- Blinkt abwechselnd mit V1 nach dem Reset im Anschluss an ein Software-Update
- Blinkt abwechselnd mit V1 falls nach einem Reset ein Daten-
fehler beim Lesen der Parameter auftrat Diagnose 2: Host-Kommunikation
- Signalisiert durch ein kurzes Blinken das Senden eines Proto-
kolls an den Host auf der RS232/RS485-Schnittstelle Reserviert Diagnose 4: RF-Warnung
- Leuchtet whrend der Reader-Initialisierung nach dem Ein-
schalten bzw. nach einem Reset.
- Leuchtet bei einem Fehler im RF-Teil des Readers. Der Feh-
lertyp kann per Software ber die RS232/RS485-Schnittstelle ausgelesen werden LED V6 (grn)
(nur Gertevari-
anten mit ACC)
"RUN-LED 2"
- Signalisiert den ordnungsgemen Ablauf des Controllers Tabelle 3-1: Konfiguration der LED FEIG ELECTRONIC GmbH Seite 21 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H 3.2 Taster / Schalter C S T U E D Kurzzeichen Beschreibung T1 T2 S1 Reset-Taster RF Controller Reset-Taster ACC Reserviert Tabelle 3-2: Taster / Schalter
- T1: Durch bettigen von T1 wird am RF-Controller ein Reset durchgefhrt
- T2: Durch bettigen von T2 wird am ACC ein Reset durchgefhrt FEIG ELECTRONIC GmbH Seite 22 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 4 Inbetriebnahme 4.1 Schnittstellenkonfiguration 4.1.1 RS485/RS422 H C S T U E D ber die Jumper J7 J8 kann die asynchrone Schnittstelle als RS485- oder RS422-Schnittstelle konfiguriert werden. Jumper RS485 J7 J8 Geschlossen Geschlossen RS422 offen offen Tabelle 4-1: Konfiguration der RS485/RS422-Schnitstelle Es knnen die eventuell bentigten Abschlusswiderstnde mit den Jumpern J1 bis J6 zugeschaltet werden. Jumper Geschlossen offen J1 J2 J5 J3 J4 J6 Pull-Up an RS4xx - B ohne Pull-Up an RS4xx - B Pull-Down an RS4xx - A ohne Pull-Down an RS4xx A Abschlusswiderstand RS4xx - A RS4xx - B Pull-Up an RS422 - Z ohne Abschlusswiderstand RS485 - A RS485 - B ohne Pull-Up an RS422 - Z Pull-Down an RS422 - Y ohne Pull-Down an RS422 Y Abschlusswiderstand RS422 - Y RS422 - Z ohne Abschlusswiderstand RS422 - Y RS422 - Z Tabelle 4-2: Abschlusswiderstnde der RS485/RS422 FEIG ELECTRONIC GmbH Seite 23 von 56 M60801-0de-ID-B.doc H C S T U E D OBID i-scan Montage ID ISC.LRU2000 500 Ohm J1 J8 J7 500 Ohm 120 Ohm J5 J2 RS485 +
RS485 -
J3 500 J1 500 J6 120 J5 J4 500 120 J2 500 RS422 Z+
RS422 Y-
RS422 B+
RS422 A-
Bild 4-1: Jumper der RS485-Schnittstelle Bild 4-2: Jumper der RS422-Schnittstelle J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1 X7 X6 Bild 4-3: Jumper der RS485/RS422-Schnittstelle Tabelle 4-3 zeigt die Standardkonfiguration der Jumper J9 bis J12. Diese sind fr die RS485 und RS422 identisch. Jumper LRU2000 Gertevarianten mit ACC LRU2000 Gertevarianten ohne ACC J9 J10 J11 J12 Geschlossen Geschlossen offen offen offen Geschlossen offen Geschlossen Tabelle 4-3: Standardkonfiguration der RS485/RS422 FEIG ELECTRONIC GmbH Seite 24 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H C S T U E D 4.1.1.1 Adresseinstellung RS485/RS422x fr Busbetrieb Fr den Busbetrieb bietet der Reader die Mglichkeit die bentigte Busadresse per Software zu vergeben. Die Adressvergabe erfolgt ber den Host-Rechner. Mit Hilfe der Software knnen dem Reader die Adressen "0" bis "254" zugewiesen werden. Hinweis:
Da alle Reader werksseitig die Adresse 0 eingestellt haben, mssen sie nacheinander ange-
schlossen und konfiguriert werden. 4.1.2 Netzwerkanschluss - LAN Vorraussetzung fr den Einsatz des TCP/IP-Protokolls ist, dass jedes Gert am Netzwerk ber eine eigene IP-Adresse verfgt. Alle Reader verfgen ber eine werksseitig voreingestellte IP-
Adresse. Die Reader mssen nacheinander ans Netzwerk angeschlossen und konfiguriert werden. Tabelle 4-4 zeigt die Standardkonfiguration des Netzwerkanschlusses. Netzwerk Adresse IP-Adresse Subnet-Mask Port 192.168.10.10 255.255.255.0 10001 Tabelle 4-4: Standardkonfiguration des Netzwerkanschlusses FEIG ELECTRONIC GmbH Seite 25 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H 5 Funkzulassungen C S T U E D 5.1 Europa (CE) Die Funkanlage entspricht, bei bestimmungsgemer Verwendung den grundlegenden Anforde-
rungen des Artikels 3 und den brigen einschlgigen Bestimmungen der R&TTE Richtlinie 1999/5/E6 vom Mrz 99. Bei Betrieb im Band b2 nach ERC/REC 70-03 Annex 11 (865,6MHz 867,6MHz) gelten folgende Einschrnkungen fr (Stand: Juli 2006):
sterreich, Belgien, Bulgarien, Kroatien, Zypern, Est-
land, Frankreich, Griechenland, Ungarn, Irland, Italien, Letland, Lichtenstein, Litauen, Luxemburg, Norwegen, Portugal, Rumnien, Slovakische Republik, Slovenien, Spanien, Schweden, Niederlande, Trkei, Grobritan-
nien Estland Frequenzbereich nicht implementiert Individuelle Lizenz bentigt Bei Betrieb im Band I nach ERC/REC 70-03 Annex 1 (869,400MHz 869,650MHz) gelten folgen-
de Einschrnkungen fr (Stand: Juli 2006):
Bulgarien Italien Slovakische Republik Frequenzbereich nicht implementiert max 25 mW e.r.p. max 10 mW e.r.p. 5.2 USA (FCC) FCC ID: PJMLRU2000 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communica-
tions Commission Rules permitting the operation of this device. FEIG ELECTRONIC GmbH Seite 26 von 56 M60801-0de-ID-B.doc OBID i-scan Montage ID ISC.LRU2000 H C S T U E D 6 Technische Daten Mechanische Daten Gehuse Kunststoffgehuse mit Khlblech Abmessungen ( B x H x T ) 180 x 320 x 110 mm Gewicht Schutzart Farbe 2,0 kg IP 54 RAL 9011 Elektrische Daten Spannungsversorgung Leistungsaufnahme Betriebsfrequenz Sendeleistung Modulationsgrad Empfnger Antennenanschlsse 4 x gemultiplext Ausgnge:
- 1 Optokoppler
- 1 Differenzausgang
- 1 Relais ( 1 x Wechsler) 15 V DC bis 24 V DC 5 %
Noise Ripple : max. 150 mV max. 30 VA 869,525 MHz (EN 300 220) 865,6 867,6MHz (EN 302 208) 902-928MHz (FCC CFR 47 Part 15.247) 100 mW 3 W (100 mW Step Software) 4 W EIRP (FCC CFR 47 Part 15.247) 2 W ERP (EN 302 208) 0,5Watt ERP (EN 300 220) 20% - 40% und 100%
(per Software einstellbar) Datenraten 40 320 kbps 4 x SMA Buchse (50) 24 V DC / 30 mA (galvanisch getrennt) Reader Synchronisation 24 V DC / 2 A FEIG ELECTRONIC GmbH Seite 27 von 56 M60801-0de-ID-B.doc H C S T U E D OBID i-scan Montage ID ISC.LRU2000 Eingnge
- 1 Optokoppler
- 1 Differenzeingang Schnittstellen Protokoll Modi Untersttzte Transponder Signalgeber optisch Umgebungsbedingungen Temperaturbereich
- Betrieb
- Lagerung Vibration Schock Angewendete Normen Zulassung Funk
- Europa
- USA EMV Sicherheit
- Niederspannung
- Human Exposure max. 24 V DC/ 20 mA Reader Synchronisation
- RS232
- RS485 / RS422 (wahlweise einstellbar)
- Ethernet (TCP/IP) (Nur Gertevariante mit ACC)
- FEIG ISO Host
- Buffer Reader Mode (Data Filtering and buffe-
ring)
- 18000-6-B
- EPC class 1 gen 1
- EPC class 1 gen 2 6 LEDs zur Diagnose des Betriebszustandes
-25C bis +55C (-25C bis +70C)
-25C bis +85C EN60068-2-6 10 Hz bis 150 Hz : 0,075 mm / 1 g EN60068-2-27 Beschleunigung : 30 g EN 302 208 EN 300 220 FCC 47 CFR Part 15 EN 301 489 EN 60950 EN 50364 FEIG ELECTRONIC GmbH Seite 28 von 56 M60801-0de-ID-B.doc H S I L G N E OBID i-scan Installation Note ID ISC.LRU2000 Copyright 2004 - 2006 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. Use Exclusion in Transportation Market: Devices which are subject of this document may NOT be sold, used, leased, offer for sale, or otherwise transferred, exported, and imported by anyone in the Transportation Market. Transportation Market means (i) Electronic Toll and Traffic Management (ETTM), (ii) Public Sector Vehicle Registration, Inspection and Licensing Programs, (iii) Railroad Locomotive and Wagon tracking, (iv) airport based ground transportation management systems (GTMS) and taxi dispatch, (v) revenue based parking, and (vi) vehicle initiated mobile payment applications, where the RFID sticker/tag is initially attached to the vehicle but not incorporated at the point of vehicle manufacture. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH. FEIG ELECTRONIC GmbH Page 30 of 56 M60801-0de-ID-B.doc OBID i-scan Installation Contents ID ISC.LRU2000 1 2 Safety Instructions / Warning - Read before start-up !
Performance Features of Reader Family ID ISC.LRU2000 33 34 H S I L G N E 2.1 2.2 Performance features..................................................................................................34 Available Reader types ...............................................................................................34 2.3 Installation ...................................................................................................................35 2.3.1 Cable glands .................................................................................................................36 2.3.2 Opening the cover .........................................................................................................37 2.4 2.5 2.6 Terminals .....................................................................................................................38 Antenna connection....................................................................................................39 Supply voltage.............................................................................................................40 2.7 Inputs / Outputs...........................................................................................................41 2.7.1 Optocouplers .................................................................................................................41 2.7.2 Relay .............................................................................................................................43 2.7.3 Reader synchronization.................................................................................................44 2.8 External diagnostic LED connections.......................................................................45 2.9 Interfaces .....................................................................................................................46 2.9.1 RS232 interface.............................................................................................................46 2.9.2 RS485/RS422 interface.................................................................................................47 2.9.3 Network connection.......................................................................................................48 2.9.4 CompactFlash Slot (only device version with ACC) ...................................................48 3 Operating and Display Elements 49 3.1 3.2 LEDs .............................................................................................................................49 Buttons / Switches ......................................................................................................50 4 Startup 51 4.1 Interface configuration................................................................................................51 4.1.1 RS485/RS422 ...............................................................................................................51 FEIG ELECTRONIC GmbH Page 31 of 56 M60801-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU2000 4.1.2 Network connection - LAN.............................................................................................53 5 Radio Approvals 54 5.1 5.2 Europe (CE)..................................................................................................................54 USA (FCC) ....................................................................................................................54 6 Technical Data 55 FEIG ELECTRONIC GmbH Page 32 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 1 Safety Instructions / Warning - Read before start-up !
The device may only be used for the purpose intended by the manufacturer When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation of 23cm between antenna and the human body must be maintained. The operation manual should be kept readily available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude the manufacturer from any liability. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be undertaken by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in the immediate proximity of the devices antenna for any length of time. H S I L G N E FEIG ELECTRONIC GmbH Page 33 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 2 Performance Features of Reader Family ID ISC.LRU2000 2.1 Performance features The Reader has been developed for reading passive data carriers, so-called Smart Labels, using an operating frequency in the UHF range. H S I L G N E 2.2 Available Reader types The following Readers are currently available:
Reader type ID ISC.LRU2000-A-EU ID ISC.LRU2000-A-FCC ID ISC.LRU2000i-A-EU ID ISC.LRU2000i-A-FCC Table 2-1 Reader types Description Device version with ACC for Europe Device version with ACC for USA Device version with ACC and internal antenna for Europe Device version with ACC and internal antenna for USA Reader module type ID ISC.LRMU2000-B-EU ID ISC.LRMU2000-B-FCC Table 2-2 Reader module types Description Module version without ACC for Europe Module version without ACC for USA FEIG ELECTRONIC GmbH Page 34 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 2.3 Installation The Reader is designed for wall-mount, including outdoors. Holes for mounting on a wall are provided in the housing. 90 H S I L G N E 6 1 3
. 5 0 0 3 161 180 Fig. 2-1 Installation drawing FEIG ELECTRONIC GmbH Page 35 of 56 M60801-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU2000 2.3.1 Cable glands The cable glands are located on the underside of the housing. Fig. 2-2: Installation drawing shows the arrangement, and Table 2-3: Cable glands for ID ISC.LRU2000 indicates which cable glands should be used for the individual lines. 6 7 1 2 3 8 4 9 5 Fig. 2-2 Installation drawing Cable gland Size 1 2 3 4 5 6 7 8 9 M 16 M 16 M 16 M 16 M 12 M 16 M 16 M 12 M 25 Clamping range
[mm]
4.5 10 4.5 10 4.5 10 4.5 10 3.5 7 4.5 10 4.5 10 3.5 7 9 17 Description Antenna cable Antenna cable Antenna cable Antenna cable Supply voltage In-/Outputs/Interface In-/Outputs/Interface In-/Outputs/Interface Network connection (optional) Table 2-3: Cable glands for ID ISC.LRU2000 FEIG ELECTRONIC GmbH Page 36 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 2.3.2 Opening the cover Fig. 2-3 Opening the cover shows how to open up the housing. H S I L G N E Fig. 2-3: Opening the cover FEIG ELECTRONIC GmbH Page 37 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 H S I L G N E 2.4 Terminals X20 V1 V2 V3 V4 V5 V6 X14 S1 T1 T2 C C A D N G
A
B
Y
Z GND X13 VDC X12 J20 X11 1 J 2 J 2 1
....J
C O
E O
N
N I I D N G
A
B
Y
Z NO X9 COM D N G D x R D x T X5 X6 X7 X8 X1 X2 X3 X4 Fig. 2-4: Reader terminals FEIG ELECTRONIC GmbH Page 38 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 2.5 Antenna connection The external antenna is connected on the analog circuit board. The maximum tightening torque for the SMA sockets is 0.45 Nm. Caution:
Exceeding the tightening torque will destroy the plug. Terminal Description X1, X2 X3, X4 Connection for external antennas
(input impedance 50) Table 2-4: External antenna connection H S I L G N E FEIG ELECTRONIC GmbH Page 39 of 56 M60801-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU2000 2.6 Supply voltage The supply voltage of 15 to 24 VDC is connected to Terminal X13. Terminal Abbreviation Description X13 / Pin 1 X13 / Pin 2 Table 2-5: Pin-outs for supply voltage VDC GND Vcc supply voltage Ground supply voltage D N G C D V 2 1 X13 Fig. 2-5 Connecting the supply voltage Note:
Reversing the supply voltage polarity may destroy the device. FEIG ELECTRONIC GmbH Page 40 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 2.7 Inputs / Outputs 2.7.1 Optocouplers The optocouplers on Terminal X6 are galvanically isolated from the Reader electronics and must therefore be externally supplied. H S I L G N E Terminal Abbreviation Description 1 2 3 4 O-C O-E IN+
IN-
Collector Output 1 Emitter Output 1
+ Input 1
- Input 1 Table 2-6: Optocoupler pin-outs Rint X6 4 3 2 1 Rext IN-
IN+
O-E O-C Uext. Uext. Fig. 2-6: Internal and possible external wiring of the optocouplers FEIG ELECTRONIC GmbH Page 41 of 56 M60801-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU2000 Optocoupler output (X6/1-2):
The transistor connections, collector and emitter, of the optocoupler output are galvanically isolated from the Reader electronics and are carried to the outside without any internal ancillary circuitry on Terminal X6. The output must therefore be powered by an external power supply. Note:
The output is configured for max. 24 V DC / 30 mA. Polarity reversal or overload on the output will destroy it. The output is intended for switching resistive loads only. Optocoupler input (X6/3-4):
The input LED associated with the optocoupler is connected internally to a series resistor of 500 . For supply voltages of greater than 10V the input current must be limited to max. 20 mA by means of an additional series resistor (see Table 2-7). Table 2-7 shows the necessary external resistors for various external voltages Uext. External voltage Uext Required external series resistor Rext 5 V ... 10 V 11 V ... 15 V 16 V ... 20 V 21 V ... 24 V
270 560 820 Table 2-7: Required external series resistor Rext Notes:
The input is configured for a maximum input voltage of 24 V DC and an input current of max. 20 mA. Polarity reversal or overload on the input will destroy it. FEIG ELECTRONIC GmbH Page 42 of 56 M60801-0de-ID-B.doc OBID i-scan 2.7.2 Relay Installation ID ISC.LRU2000 H S I L G N E A relay output is provided in the form of a changeover relay. Terminal Abbreviation Description 1 2 3 COM Working contact NC NO Normally closed Normally open Table 2-8: Relay output pin-outs Notes:
The relay output is configured for max. 24 V DC / 2 A. The relay output is intended for switching resistive loads only. If an inductive load is connected, the relay contacts must be protected by means of an external protection circuit. ext.U X9 3 2 1 O N C N M O C Fig. 2-7: Internal and possible external wiring of the relay output FEIG ELECTRONIC GmbH Page 43 of 56 M60801-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU2000 2.7.3 Reader synchronization Reader synchronization can be used to synchronize various Reader actions. Terminal Abbreviation Description 1 2 3 4 5 GND A-
B+
Y-
Z+
GND
- Input
+ Input
- Output
+ Output Table 2-9: Reader synchronization pin-outs OUT+ (Z+) OUT- (Y-) IN+ (B+) IN- (A-) GND X5 5 4 3 2 1 Fig. 2-8: Synchronization input and output FEIG ELECTRONIC GmbH Page 44 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 2.8 External diagnostic LED connections X14 allows for connection of additional external LEDs in parallel with the internal diagnostic LEDs. The external LEDs are connected as shown in Fig. 2-9. H S I L G N E Terminal Abbreviation Description 1 2 3 4 5 6 V1 Anode ext. V2 Anode ext. V3 Anode ext. V4 Anode ext. V5 Anode ext. GND Function same as internal LED V1 Function same as internal LED V2 Function same as internal LED V3 Function same as internal LED V4 Function same as internal LED V5 Common GND Table 2-10: External LED pin-outs ACC-Modul V5 V6 X14 S1 T1 X14 4 2 31 6 5 X14 1 2 3 4 5 6 V5 V4 V3 V2 V1 external LEDs Fig. 2-9: Connecting external LEDs to X14 Note:
The outputs on X14 are intended for switching an external LED only. Overloading the outputs with other loads may destroy them. FEIG ELECTRONIC GmbH Page 45 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 2.9 Interfaces 2.9.1 RS232 interface The RS232 interface is connected on X8. The transmission parameters can be configured by means of software protocol. H S I L G N E Pin configuration X8 (RS232 interface):
Terminal Abbreviation Description 1 2 3 GND RxD TxD RS232 GND RS232 - RxD RS232 - TxD Table 2-11: RS232 interface pin-outs X8 3 2 1 TxD RxD GND 9-pol. D-SUB-Jack PC X8 / 1 X8 / 2 X8 / 3
Pin 5 Pin 3 Pin 2 Fig. 2-10: Wiring example for connecting the RS232 interface FEIG ELECTRONIC GmbH Page 46 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 2.9.2 RS485/RS422 interface The second asynchronous interface can be configured for RS485 or RS422 (see Section Interface configuration). The RS485/RS422 interface is connected on X7. Pin configuration X7 (RS485/RS422 interface):
Terminal Abbreviation Description 1 2 3 GND RS485/RS422 GND A-
B+
RS485/RS422 (A -) RS485/RS422 (B +) 4 5 RS422 (Y -) RS422 (Z +) Table 2-12: RS485/RS422 interface pin-outs Y-
Z+
H S I L G N E RS422 (Z+) RS422 (Y-) RS485/RS422 (B+) RS485/RS422 (A-) RS485/RS422 GND X7 5 4 3 2 1 Fig. 2-11: Wiring example for the RS485/RS422 interface FEIG ELECTRONIC GmbH Page 47 of 56 M60801-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU2000 2.9.3 Network connection 2.9.3.1 LAN (only device versions with ACC) The Reader has an integrated 10/100Tbase network port for an RJ45. Connection is made on X11. With structured cabling Cat 5 cables should be used. This ensure reliable operation at 10Mbps or 100Mbps. Pin configuration for X8 (network interface):
Terminal Abbreviation Description 1 2 3 4 5 6 7 8 TX+
TX-
RX+
VETH+
VETH+
RX-
VETH-
VETH-
Transmit Data +
Transmit Data -
Receive Data +
n.c. n.c. Receive Data -
n.c. n.c. Table 2-13: Ethernet interface pin-outs 2.9.4 CompactFlash Slot (only device version with ACC) The Reader has a CF2 slot (connector X12). This slot is for future use by CompactFlash cards. FEIG ELECTRONIC GmbH Page 48 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 3 Operating and Display Elements 3.1 LEDs Table 3-1 shows the LED configuration. H S I L G N E Abbreviation LED V1 (green) LED V2 (blue) Description Indicates proper running of the internal Reader software (DSP)
"RUN-LED 1"
Diagnostic 1: RF communication / EEPROM status
- Short flashing indicates errorless communication with a transponder on the RF interface
- Flashes alternately with V1 after a reset following a software update
- Flashes alternately with V1 in case of a data error when reading the parameters after a reset LED V3 (yellow) Diagnostic 2: Host communication
- Short flashing indicates sending of a protocol to the host on the RS232/RS485 interface LED V4 (yellow) Reserved LED V5 (red) Diagnostic 4: RF warning
- Comes on during Reader initialization after power-on or after a reset.
- Comes on when there is an error in the RF section of the Reader. The error type can be read out via software over the RS232/RS485 interface LED V6 (green)
(only device version with ACC)
"RUN-LED 2"
Indicates proper running of the AC Controller Table 3-1: LED configuration FEIG ELECTRONIC GmbH Page 49 of 56 M60801-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.LRU2000 3.2 Buttons / Switches Abbreviation Description T1 T2 S1 RF Controller reset button ACC reset button Reserved Table 3-2: Buttons / Switches
- T1: Pressing T1 resets the RF Controller
- T2: Pressing T2 resets the ACC FEIG ELECTRONIC GmbH Page 50 of 56 M60801-0de-ID-B.doc OBID i-scan 4 Startup 4.1 Interface configuration 4.1.1 RS485/RS422 Installation ID ISC.LRU2000 H S I L G N E Jumpers J7 J8 are used to configure the asynchronous interface as an RS485 or R422 port. Jumper J7 J8 RS485 closed closed RS422 open open Table 4-1: Configuration of the RS485/RS422 port Any termination resistors needed can be enabled using jumpers J1 through J6. Jumper Closed Open J1 J2 J5 J3 J4 J6 Pull-Up on RS4xx - B Pull-Down on RS4xx - A without Pull-Down on RS4xx A without Pull-Up on RS4xx - B Termination resistor without Termination resistor RS4xx - A RS4xx - B RS485 - A RS485 - B Pull-Up on RS422 - Z Pull-Down on RS422 - Y without Pull-Up on RS422 - Z without Pull-Down on RS422 Y Termination resistor without Termination resistor RS422 - Y RS422 - Z RS422 - Y RS422 - Z Table 4-2: Termination resistors for RS485/RS422 FEIG ELECTRONIC GmbH Page 51 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 500 Ohm J1 J8 J7 500 Ohm 120 Ohm J5 J2 RS485 +
RS485 -
J3 500 J1 500 J6 120 J5 J4 500 120 J2 500 RS422 Z+
RS422 Y-
RS422 B+
RS422 A-
H S I L G N E Fig. 4-1: RS485 interface jumpers Fig. 4-2: RS422 interface jumpers J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1 X7 X6 Fig. 4-3: RS485/RS422 interface jumpers shows the standard configuration of jumpers J9 through J12. These are identical for RS485 and RS422. Jumper LRU2000 device version with ACC LRU2000 device version without ACC J9 J10 J11 J12 closed closed open open open closed open closed Table 4-3: Standard configuration for RS485/RS422 FEIG ELECTRONIC GmbH Page 52 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 H S I L G N E 4.1.1.1 Address assignment of RS485/RS422 for bus operation For bus operation the Reader can be assigned the required bus address via software. The address is assigned by the host computer. The software is used to assign addresses 0 through 254 to the Reader. Note:
Since all Readers are factory set with address 0, they must be connected and configured one after the other. 4.1.2 Network connection - LAN The prerequisite for using TCP/IP protocol is that each device has a unique address on the network. All Readers have a factory set IP address. The Readers must be connected and configured one after the other. Table 4-4: shows the standard configuration of the network connection. Network Address IP address Subnet mask Port 192.168.10.10 255.255.255.0 10001 Table 4-4: Standard configuration of the network connection FEIG ELECTRONIC GmbH Page 53 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 5 Radio Approvals 5.1 Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. H S I L G N E Operation not currently permitted Restrictions for operating the ID ISC.LRU2000 (Effective: July 2006):
When operating the ID ISC.LRU2000 in Band b2 ERC/REC 70-03 Annex 11 (865,6MHz 867,6MHz) the following restrictions apply:
Austria, Belgium, Bulgaria, Croatia, Cyprus, France, Greece, Hungary, Ireland, Italy, Latvia, Lichtenstein, Lithuania, Luxembourg, Norway, Portugal, Romania, Slovak Republic, Slovenia, Spain, Sweden, The Neth-
erlands, Turkey, United Kingdom Estonia When operating the ID ISC.LRU2000 in Band I ERC/REC 70-03 Annex 1 (869,400MHz 869,650MHz) the following restrictions apply:
Bulgaria Italy Slovak Republic Operation not currently permitted max 25 mW e.r.p. max 10 mW e.r.p. Operation only with individual license 5.2 USA (FCC) FCC ID: PJMLRU2000 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communica-
tions Commission Rules permitting the operation of this device. FEIG ELECTRONIC GmbH Page 54 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 6 Technical Data Mechanical Data Housing Plastic enclosure with cooling fin Dimensions ( W x H x D ) 180 x 320 x 110 mm H S I L G N E Weight Enclosure rating Color Electrical Data Supply voltage Power consumption Operating frequency Transmitting power Modulation Receiver Antenna connections 4 x multiplexing Outputs:
- 1 optocoupler
- 1 differential output
- 1 relay ( 1 x changeover) Inputs
- 1 optocoupler
- 1 differential input 2.0 kg IP 54 RAL 9011 15 V DC to 24 V DC 5 %
Noise Ripple : max. 150 mV max. 30 VA 869.525 MHz (EN 300 220) 865.6 867.6 MHz (EN 302 208) 902-928 MHz (FCC CFR 47 Part 15.247) 100 mW 3 W (100 mW Step Software) 4 W EIRP (FCC CFR 47 Part 15.247) 2 W ERP (EN 302 208) 0.5 W ERP (EN 300 220) 20% - 40% and 100%
(software configurable) Data rates 40 320 kbps 4 x SMA socket (50) 24 V DC / 30 mA (galvanically isolated) Reader synchronization 24 V DC / 2 A max. 24 V DC/ 20 mA Reader synchronization FEIG ELECTRONIC GmbH Page 55 of 56 M60801-0de-ID-B.doc OBID i-scan Installation ID ISC.LRU2000 Interfaces Protocol modes H S Supported transponders I L G N E Optical indicators Ambient Temperature range
- Operating
- Storage Vibration Shock Applicable standards RF approval
- Europe
- USA EMC Safety
- Low-Voltage
- Human Exposure
- RS232
- RS485 / RS422 (selectable)
- Ethernet (TCP/IP) (only device version with ACC)
- FEIG ISO Host
- Buffer Reader Mode (Data Filtering and buffering)
- 18000-6-B
- EPC class 1 gen
- EPC class 1 gen 2 6 LEDs for operating status diagnostics
-25C to +55C (-25C to +70C)
-25C to +85C EN60068-2-6 10 Hz to 150 Hz :0.075 mm / 1 g EN60068-2-27 Acceleration
: 30 g EN 302 208 EN 300 220 FCC 47 CFR Part 15 EN 301 489 EN 60950 EN 50364 FEIG ELECTRONIC GmbH Page 56 of 56 M60801-0de-ID-B.doc
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2007-01-11 | 902.7 ~ 927.2 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2007-01-11
|
||||
1 | Applicant's complete, legal business name |
Feig Electronic GmbH
|
||||
1 | FCC Registration Number (FRN) |
0007634793
|
||||
1 | Physical Address |
Lange Strae 4
|
||||
1 |
Weilburg-Waldhausen, N/A D-35781
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
g******@ict.cetecom.de
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
PJM
|
||||
1 | Equipment Product Code |
LRU2000
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
E**** R******
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
+49 6********
|
||||
1 | Fax Number |
+49 6********
|
||||
1 |
e******@feig.de
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID Reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Limited Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power Output listed is conducted. Limited Modular Approval. Approval is limited to OEM installation only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 23 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. OEM integrators must be provided with antenna installation instructions. OEM integrators and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Cetecom Inc.
|
||||
1 | Name |
L******** S******
|
||||
1 | Telephone Number |
408-5********
|
||||
1 | Fax Number |
510-2********
|
||||
1 |
l******@cetecomusa.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 902.70000000 | 927.20000000 | 0.9700000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC