all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Manual rev | Users Manual | 2.48 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | Test Report | |||||||
1 | Cover Letter(s) | |||||||
1 | RF Exposure Info | |||||||
1 | Test Setup Photos | |||||||
1 | Test Report |
1 | Manual rev | Users Manual | 2.48 MiB |
Annex no. 5 Functional Description /
User Manual Date: 2012-06-11 Vers. no. 1.12 m. dudde hochfrequenz-technik Rottland 5a D-51429 Bergisch Gladbach/ Germany Tel: +49 2207-96890 Fax +49 2207-968920 INSTALLATION ID ISC.PRH200 Mobile Reader
(English) draft public (B) 2014-04-28 M31210-2e-ID-B.docx Installation Note ID ISC.PRH200 OBID i-scan HF Copyright 2014 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-
ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH. my-d is a registered trademark of Infineon Technologies AG I-CODE is a registered trademark of Philips Electronics N.V. Tag-itTM is a registered trademark of Texas Instruments Incorporated. FEIG ELECTRONIC GmbH Page 2 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation Contents ID ISC.PRH200 1 Safety Instructions / Warning - Read before Start-Up 5 1.1 1.2 1.3 1.4 Safety Instructions / Warning - Lithium-ion battery ................................................. 6 Lithium-ion batteries Return and Transport .......................................................... 7 Maintenance ................................................................................................................ 8 Assembly of the wrist strap ....................................................................................... 8 2 Performance Features of the mobile Reader ID ISC.PRH200 9 2.1 2.2 2.3 2.4 Performance Features ................................................................................................ 9 Available Reader Types ............................................................................................ 10 Available Spare Parts ............................................................................................... 10 Delivery contents ...................................................................................................... 10 3 Start-up 11 3.1 3.2 Side view, Button & LEDs ....................................................................................... 11 Charge the battery .................................................................................................... 12 4 First Wi-Fi connection with the Reader and scanning transponder 13 4.1 4.2 4.3 4.4 Connection in Access point Mode ........................................................................... 13 How to configure the Reader in client mode ........................................................... 16 Set Wi-Fi parameter to default ................................................................................. 18 Wi-Fi Interfaces ......................................................................................................... 20 5 Control and Display Elements 21 5.1 5.1 5.2 5.3 Buttons ...................................................................................................................... 21 HF-ON Motion Detector ............................................................................................ 22 LEDs .......................................................................................................................... 23 Buzzer ........................................................................................................................ 24 6 Configuration and testing the Reader using ISOStart 25 FEIG ELECTRONIC GmbH Page 3 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 Approvals 30 7.1 7.2 Europe (CE) ............................................................................................................... 30 USA (FCC) and Canada (IC) ..................................................................................... 31 7.3 Label Information Reader ID ISC.PRH200 ............................................................... 33 7.3.1 USA (FCC) and Canada (IC) approved antennas ................................................... 34 Technical Data 35 7 8 FEIG ELECTRONIC GmbH Page 4 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 1 Safety Instructions / Warning - Read before Start-Up The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. Please observe that some parts of the device may heat severely. For installation and dismantling you should wear suitable safety gloves, because parts of antenna housing could be sharp-edged. The device is not water proof and should not be exposed to rain or humidity. Under extreme circumstances water could seep into the device and damage the electronic circuits. Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker. Do not holding the reader antenna for any length of time in an immediate proximity of the car-
diac pacemakers FEIG ELECTRONIC GmbH Page 5 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 1.1 Safety Instructions / Warning - Lithium-ion battery Improper use, damaged chargers or battery packs of injury and fire hazard Use the battery only in the intended device from Typ ID ISC.PRH200. Expose the battery pack for no deviating from the technical data of environmental influences. Moisture and water, dust, heat, shocks and pressure can damage or destroy the battery pack. To use a damaged, deformed or not original sealed battery pack is prohibited. You must be disposed of properly and Expertly and may no longer be shipped in Packet Lithium-ion batteries must not be in the trash, they must be disposed of separately. Find out. upon the local authorities to suitable collection Charge the battery only with the original by FEIG ELECTRONIC GmbH supplied battery charger. During charging, the ambient temperature should be between 10C and maximum 45 C. A slight warming of the battery during charging and in use is normal. Store your battery in a cool, dry place. Permitted temperature range according to technical data. The battery pack must never be shorted out. A short-circuit the battery pack can be very hot, break and break explosively Avoid reverse polarity of positive and negative poles. The battery pack may be damaged or destroyed. Do not heat or throw the battery pack of in fire. Do not charge and leave the battery pack at the high temperature. The battery pack may ignite explosively and break Never disassemble the battery pack. If disassembled battery pack, safety protection circuit may cause breaking and not operated safety system for charge and discharge. May cause heating, igniting and breaking of cell. Do not solder to terminal of battery pack. Safety protection circuit may cause breaking and may be not operated safety system for charge and discharge. If heat up battery pack over 90C, plastic parts may be melting and cell may be leaking and may cause heating, igniting and breaking by short-circuit internally. Do not subject the battery and replace the battery, no strong shocks or a strong impact. Do not leave the battery unattended during charging. Make sure that the battery label always remain on the battery pack. The informations printed on the label have to be visible during handling the battery pack. FEIG ELECTRONIC GmbH Page 6 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 1.2 Lithium-ion batteries Return and Transport Please note the following instructions for disposal or return and transport of Li-Ion batteries:
Do not load or transport Li-Ion batteries if damaged. If you have any doubts, please contact our technical support under obid-support@feig.de or phone +49 (0) 6471 3109 421. If the packaging is damaged, the packaging must be replaced by an undamaged original packaging before further transport. Li-Ion Batteries may only be returned in their original condition and packaging. The shipping regulations must be observed. In the case of a return, the following label is clearly visible attached to the parcel:
Print out this sheet in A4 format in color, cut it out and attach the label clearly visible on the pack-
age. FEIG ELECTRONIC GmbH Page 7 from 37 M31210-2e-ID-B.docx OBID i-scan HF 1.3 Maintenance Installation ID ISC.PRH200 The reader ID ISC.PRH200 is a design product with high quality surfaces, and should always be handled with caution. The Device was designed to work reliably and flawlessly for years without special maintenance. Attention! The surfaces should be cleaned with a clean, soft cloth dampened in a dishwash-
ing liquid water solution. To improve the durability and the appearance, please follow the instructions below:
Keep the reader clean and take care the reader is not scratched. Also regularly apply specific antistatic products for acrylic surfaces. Regularly remove dust and other impurities with a soft cloth and a solution of water with a little dishwashing liquid. Keep the reader dry. All kinds of moisture should be avoided during operation and storage. Precipitation, humidity and liquids contain minerals that will corrode electronic circuits and damaging transparent plastic parts. Avoid storing or operating the reader at dirty or wet locations. The surfaces or electronic com-
ponents may be-damaging. If any device not working properly, please contact the appropriate representative. 1.4 Assembly of the wrist strap The included hand strap is mounted on the provided eyelet and tightened. To avoid damage, the hand strap to secure it against falling should always be used. Fig. 1: Assembly of the wrist strap FEIG ELECTRONIC GmbH Page 8 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 2 Performance Features of the mobile Reader ID ISC.PRH200 2.1 Performance Features ID ISC.PRH200 is a compact, wireless handheld reader, designed for contactless data exchange with ISO 15693 transponders, especially in libraries. Typical applications are:
Inventory (Inventory books or other media in the shelf) Sorting of books or media in a shelf Locate a book or media in a shelf or box, automatic checking / rewriting of the AFI bytes of all media. Further applications are laundries, logistical processes as well as document and asset manage-
ment. In these areas it is possible to work with ISO 18000-3M3 transponders, optionally. Depending on the type of media and the reading distance, the output power can be switched be-
tween two levels (Standard Mode: 1.5 W and Boost Mode: 4 W). Power supply is a Lithium Ion rechargeable battery that allows for operating times up to 16 hours*. If necessary, the battery can be replaced easily and quickly. 5 multi-colored LED lights and an integrated sounder act as display elements. Thereby all relevant states are visible on both sides of the device. Communication with a data base or computer take place through a Wi-Fi interface on the reader, that supports the most common encryption protocols. FEIG ELECTRONIC GmbH Page 9 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 2.2 Available Reader Types Article No. 4213.000.00 Reader ID ISC.PRH200 Table 1: Available Reader Types 2.3 Available Spare Parts Description Mobile Reader with rechargeable battery and Wi-Fi-Interface Spare part ID ISC.SRB Spare Rechargeable Battery ID CHA.Li-Ion Recharger Article No. 4214.000.00 4215.000.00 Table 2: Available Spare parts Description Spare or additional battery-pack Spare charger for battery-pack 2.4 Delivery contents Mobile Reader with battery and Wi-Fi-Interface Lithium-ion battery pack Wall power charger & Adapter Set for international socket-outlet Wrist strap Installation instructions FEIG ELECTRONIC GmbH Page 10 from 37 M31210-2e-ID-B.docx Installation ID ISC.PRH200 LED RF-ON LED Wi-Fi LED MODE OBID i-scan HF 3 Start-up 3.1 Side view, Button & LEDs LED APPL LED BATT RF-ON Power-ON Fig. 2: Housing ID ISC.PRH200 Eyelet for wrist strap FEIG ELECTRONIC GmbH Page 11 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 3.2 Charge the battery The battery pack is charged using the supplied charger. For this, the Mini-DIN connector from the charger is plugged into the side the battery pack. After installation of the adapter socket for the charger, the charger must be connected to the mains. The charging will take 2-4 hours. The battery is fully charged when the green LED remains lit on the power supply. The device is supplied with three different removable adapter / plug:
Adapter Country of use EU US / Canada / Japan Great Britain Table 3: Removable adapter for the charger Fig. 3: Charger with battery pack Note:
A new battery is delivered almost uncharged. Therefore, it must be fully charged before use. A new battery has not until after the second or third charging / discharging the full capacity. This also applies after a break of operation of a few months. FEIG ELECTRONIC GmbH Page 12 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 4 First Wi-Fi connection with the Reader and scanning transponder Before first use, the battery pack should be charged. See 3.2 Charge the battery. The battery pack must be connected to the charger. The charging will take 2-4 hours. The battery is fully charged when the green LED remains lit on the power supply. To configure the Reader you will need the software tool ISOStart Version 9.07 or higher on a personal computer running under Microsoft Windows with Wi-Fi interface The service tool can be downloaded from the Download Area of the FEIG Homepage www.feig.de. The delivered reader is set on to the factory default settings and works as a "Access Point" and generates its own wireless network with the name (SSID) "PRH200" without encryption. The wire-
less interface of the corresponding PC or laptop must be configured to "Client Mode" and DHCP
"ON". 4.1 Connection in Access point Mode Step Boot the Computer boot with Wi-Fi on. Adopt the battery pack plug into the slot on the reader. The battery pack clicks into place. Reader ON: Short press on Power-ON Button. No. 1. 2. 3. Note FEIG ELECTRONIC GmbH Page 13 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 Step LED MODE (green) will light and LED Wi-Fi flashes slowly. After about 5 seconds, the Wi-Fi LED flashes with about 8 Hz Open window "Wireless Connections" on your PC and search for the network name (SSID) PRH200. No. 4. 5. 6. Connect to the network PRH200. Confirm the network
"PRH200" as a home or workplace network. 7. 8. Your Computer connects to the Reader PRH200, now Note FEIG ELECTRONIC GmbH Page 14 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 No. Step The white LED Wi-Fi is off, the green LED MODE remains on. 9. Note For the configuration and testing the Reader the demo program ISOStart can be used (Version 9.7.1 or higher). The next steps are described in the chapter:
Configuration and testing the Reader using ISOStart 10. Or As an alternative the demo tool PRH200-Demo can be used. The description for this tool you will find in the document H40310-0e-ID-B.pdf FEIG ELECTRONIC GmbH Page 15 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 4.2 How to configure the Reader in client mode For using the Reader in an existing WLAN infrastructure it will be necessary to configure the reader into the Client Mode. For configuring the reader into the Client Mode the WEB-interface of the reader can be used. With the help of a standard Browser on a Laptop, Smartphone or Tablet PC you can get access to the reader Web-interface by using the reader default IP address 192.168.1.1. Step Connect the Reader ID ISC.PRH200 Open a Browser and write the TCP/IP Adresse 192.168.1.1. Choose the Client button No. 1. 2. 3. Note Connect the Reader in the Access Mode via WLAN to a Laptop, Smart Phone or Tablet PC as described in the chapter 4.1 Con-
nection in Access point Mode FEIG ELECTRONIC GmbH Page 16 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 No. 4. Step Set the SSID and the Password (Key) of the WLAN network (Router) and confirm with Connect button. The IP address and the deciphering keys will be programmed automatically into the reader. Confirm the warning message with a click on the OK button. 5. The Reader performs a reset. Afterward the Mode LED
(green) lights and the WLAN LED flashes slowly. After approx. 5 seconds the WLAN LED flashes with approx. 4 Hz. As soon as the WLAN LED goes off the WLAN connection is ready to use. Check the WLAN Client-
List in the router WEB-
interface. There the new IP address assigned by DHCP will be shown. 6. 7. 8. Note FEIG ELECTRONIC GmbH Page 17 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 4.3 Set Wi-Fi parameter to default Are the Wi-Fi parameter unknown or should the device be integrated into other network, all parameters to the factory settings can be set to default by a hardware reset.. No. Step Insert a thin wire (e.g. pa-
per clip) in the hole for the reset button and hold it down. 1. At the same time press button Power ON shortly 2. Hold the Reset Button for 5 seconds. Now, all LEDs flash at 2 Hz at the same time 3. 4. Now: Release the Reset Button Immediately afterwards, press the Button Power-ON for 5 Seconds. 5.
-> The Reader switched off Note The Reader starts and the 5 LEDs flash alternately FEIG ELECTRONIC GmbH Page 18 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 Step Short press on Power-ON Button to reboot the reader No. 6. The Wi-Fi Modul is on de-
fault values, now. SSID: PRH200 Unsecured Wireless Net-
work 7. Mode: Access Point Note FEIG ELECTRONIC GmbH Page 19 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 4.4 Wi-Fi Interfaces The Reader has a built-in wireless interface according to the IEEE 802.11 b/g /n standard and can be configured in "Access Point" or the "Client Mode". The encryption protocols WEP / WPA /
WPA2 are supported. The Reader on delivery or factory setting is configured as "Access Point" and generates its own wireless network with the name (SSID) "PRH200" without encryption. The wireless interface of the corresponding PC or laptop must be configured to "Client Mode" and DHCP "ON". The reader default settings of the Wi-Fi interface are:
Parameter SIDD Password DHCP Encryption Mode Default setting PRH200
-
ON OFF Access Point Table 4: Default configuration of the reader Wi-Fi interface Network IP-Address Subnet-Mask Port DHCP Address 192.168.1.1 255.255.0.0 10001 ON Table 5: Default configuration of the reader (Wi-Fi) Ethernet Interface Note:
The Reader has a TCP/IP interface with DHCP that is turned on at the factory. It is recommended to configure a new network name (SSID) and the encryption ac-
cording WPA/WAP2 after commissioning. The minimum WPA2 encryption key length is 8 characters. FEIG ELECTRONIC GmbH Page 20 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 5 Control and Display Elements 5.1 Buttons Button RF-ON
(upper) Function / Description RF / Antenna power switch ON / OFF"
- State antenna OFF Short press -> The RF-Power of the antenna will be switched ON
- State Antenna ON Short press -> The RF-Power of the antenna will be switched OFF Power-ON
(Lower) Power ON / OFF / Reader Mode
- State Reader OFF:
Short press -> Reader ON, Standard Mode State Reader ON Short press -> Change Mode between Standard and Boost Mode) Long press -> Reader OFF
-
Table 6: Function of the Buttons Note:
The RF power of antenna is automatically switched OFF after a certain time if no transponder has been detected. The power Management is configurable in CFG21. Use parameter RF-Field: minimum on-time After the RF-Field: maximum on-time has expired the reader antenna power will switch off in any case. After switching off the antenna power and end of the Power on-time in CFG21, the complete Reader will turn off automatically. FEIG ELECTRONIC GmbH Page 21 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 5.1 HF-ON Motion Detector Due to shaking the Reader in the forward direction effectual and a fast movement the HF-filed can switched on alternatively to the use of the HF-ON button. For this the reader should be hold in the center or the upper part of the handle. The function of the movement detector can be enabled and disabled in PowerManagement of the Reader configuration using ISOStart. FEIG ELECTRONIC GmbH Page 22 from 37 M31210-2e-ID-B.docx OBID i-scan HF 5.2 LEDs Installation ID ISC.PRH200 Fig. 4: LED (Double sided) Table 6 show the function of the LEDs (Order from top to down). LED LED RF-ON
(green/blue) LED APPL
(green, red) LED Wi-Fi
(white) LED BATT
(orange, red) LED MODE
(green, white) Function / Description
"RF-ON / Transponder"
- Green: The antenna is powered
- Blue: One or more transponder are detected Application / Special function
- Controlled by command Set Output
- Green: Special functions enabled (Locate Transponder by UID, data, AFI functions)
- Red: Special functions: Transponder detected Wi-Fi
- OFF: Reader is connected via Wi-Fi to the Host
- Flash: Wi-Fi connection runs Wi-Fi device lost connection Battery Status
- OFF: Battery charged
- Orange: Battery reaches 15% of charge capacity, Boost Mode isnt possible.
- Red: Battery empty the antenna cant switched on.
- Red (flashing): Automatic shut-off after 5 seconds Power-On / Reader Mode
- Normal Mode : green
- Boost Mode: white Table 7: Configuration of the LEDs FEIG ELECTRONIC GmbH Page 23 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 5.3 Buzzer The reader has a integrated buzzer. The buzzer will be activated, if at least one of the configuration bits in the Digital IO is enabled. Fig. 5: Configuration of the Digital IO FEIG ELECTRONIC GmbH Page 24 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 6 Configuration and testing the Reader using ISOStart Select Detect with TCP/IP Address 192.168.1.1. and Port 10001 1. Select Run without change This has to be done at each start of ISO-Start program otherwise the configuration of the reader will be changed by the wizard. 2. FEIG ELECTRONIC GmbH Page 25 from 37 M31210-2e-ID-B.docx OBID i-scan HF Select the Logical View for the reader configuration settings 3. 4. Select Configuration Select Operating Mode and then choose "Buff-
ered Read Mode" for the reader Mode and mark UID as data. 5. 6. Set by a click on Apply. Select Filter and set the TransponderValid Time. E.g. 10s 7. 8. Set by a click on Apply Installation ID ISC.PRH200 FEIG ELECTRONIC GmbH Page 26 from 37 M31210-2e-ID-B.docx OBID i-scan HF Select Buffered Read Mode 9. 10. Select Button Initialize to clear the data buffer of the reader Press button RF-ON to enable the antenna power 11. The LED RF ON is lit green 12. Installation ID ISC.PRH200 FEIG ELECTRONIC GmbH Page 27 from 37 M31210-2e-ID-B.docx OBID i-scan HF Move the reader antenna along the media or Tranponder 13. If valid data is detected LED HF -ON lit blue 14. After the end of the reading antenna pro-
cess, switch OFF the RF antenna power 15. LED HF_ON goes off 16. 17. Select Start Button to transfer the data from the reader to your Computer Installation ID ISC.PRH200 FEIG ELECTRONIC GmbH Page 28 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 All stored transponder data sets are listed in the ISO Start window. The number of data sets and the total processing time is displayed in the header 18. Before the next read operation, the display window can be deleted by the Clear List button To read more data, re-
peat step 22-31 19. 20. Note:
To avoid unwanted readings and to save energy the reader antenna turns off the RF antenna power according to a configured time automatically. If not all transponder data are read, the "Boost Mode" with greater transmit power can be used. See: 4.1 Buttons FEIG ELECTRONIC GmbH Page 29 from 37 M31210-2e-ID-B.docx OBID i-scan HF 7 Approvals Installation ID ISC.PRH200 7.1 Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Page 30 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 7.2 USA (FCC) and Canada (IC) Product names:
Reader name:
FCC ID:
IC:
Notice for USA and Canada ID ISC.PRH200 ID ISC.MR102 PJMPRH200 6633A-PRH200 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Unauthorized modifications may void the authority granted under Federal communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Le prsent appareil est conforme aux CNR d'Industrie Canada appli-
cables aux appareils radio exempts de licence. L'exploitation est auto-
rise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonc-
tionnement. Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. Installation with FCC / IC Approval:
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada. FEIG ELECTRONIC GmbH Page 31 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 A minimum separation distance of 20cm must be maintained between the Wi-Fi antenna (See pic-
ture below) and all persons at all times. Une distance minimale de sparation de 20 cm doit tre maintenue entre l'antenne Wi-Fi (voir pic-
ture ci-dessous) et toutes les personnes tout moment. Wi-Fi Antenna FEIG ELECTRONIC GmbH Page 32 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 7.3 Label Information Reader ID ISC.PRH200 The following labels are placed on the bottom side of the reader:
ID ISC.PRH200 FEIG ELECTRONIC GmbH Page 33 from 37 M31210-2e-ID-B.docx OBID i-scan HF Installation ID ISC.PRH200 7.3.1 USA (FCC) and Canada (IC) approved antennas This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with maxi-
mum permission gain and required antenna impedance for each antenna type indicated. Antenna types, not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device Le prsent metteur radio (identifier le dispositif par son numro de certification ou son numro de modle sil fait partie du matriel de catgorie I) a t approuv par Industrie Canada pour fonc-
tionner avec les types dantenne nonc ci-dessus et ayant un gain admissible maximal et limpdance requise pour chaque type dantenne. Les types dantenne non inclus dans cette liste, ou dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour lexploitation de lmetteur FEIG ELECTRONIC GmbH Page 34 from 37 M31210-2e-ID-B.docx OBID i-scan HF 8 Technical Data Mechanical Data Reader & Antenna Dimensions ( W x H x D ) Reader with antenna Packing Weight Reader , antenna and battery Packing Housing Color reader & antenna Color battery pack Enclosure rating Electrical data Reader Supply Voltage
-Operation Time
- Standard Mode
- Boost Mode Operating Frequency RF-Power
- Standard Mode
- Boost Mode Button Reset-Button LEDs Installation ID ISC.PRH200 460 mm x 260 mm x 27 mm, antenna ca: 1,5 mm thick 570 mm x 390 mm x 76 mm 0.6 kg 1.55 kg ABS/PC RAL 7046 / RAL 7047 black IP 30 Battery Pack ca. 8 h ca. 4 h 13,56 MHz 1,5 W 4,0 W RF-ON: ON / OFF Power-ON: HF ON / OFF Reset to factory settings 1. RF-ON 2. Application 3. Wi-Fi 4. Battery 5. Power-On / Mode FEIG ELECTRONIC GmbH Page 35 from 37 M31210-2e-ID-B.docx OBID i-scan HF Signal buzzer Interfaces Wi-Fi Security Protocols Wi-Fi Modes Interface protocol modes Supported Transponder Ambient Conditions Temperature range Operating Storage Protection class Humidity Freefall Approvals Radio approvals Europe EMC Electrical Data Battery Pack Nominal Voltage Nominal capacitance Maximal charging voltage Maximal charge current Temperature range Operating Storage Battery connector Dimensions ( W x H x D ) Packing (Spare part) Installation ID ISC.PRH200 1 Ton Wi-Fi WEP / WPA / WPA2
- Access Point Mode
- Client Mode
- FEIG ISO HOST
- BRM (Datenfilterung und Datenpufferung)
- Notifikation Mode ISO15693
-0C bis +40C
-25C bis +85C IP 30 5% - 80%, non-condensing 1,0 m EN 300 330 EN 301 489 10,8 V 3,35Ah (typical) 12,6 V 1,5 A
+10C bis 45C
- 20C bis 60C Mini-DIN 360 mm x 110 mm x 100 mm FEIG ELECTRONIC GmbH Page 36 from 37 M31210-2e-ID-B.docx OBID i-scan HF Weight
- battery Packing Electrical data battery charger Supply Voltage Output Voltage Efficiency Type Dimensions ( W x H x D ) Packing Weight Packing (Spare part) Approval marks Charging time Temperature range Operating Storage Humidity Installation ID ISC.PRH200 240g 470g
/ 1,2 A 100V 240 V 47 Hz 64 Hz Maximal 12,44V 73% - 83%
Wall power battery charger & Adapter Set for inter-
national socket-outlet 210 mm x 75 mm x 50 mm 270g CE UL listed SELV EN 55011 group I Class B 3,5-4 h 5 C bis +40 C 25 C bis +80 C Up to 95%, non-condensing FEIG ELECTRONIC GmbH Page 37 from 37 M31210-2e-ID-B.docx
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2014-05-27 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2014-05-27
|
||||
1 | Applicant's complete, legal business name |
Feig Electronic GmbH
|
||||
1 | FCC Registration Number (FRN) |
0007634793
|
||||
1 | Physical Address |
Lange Strae 4
|
||||
1 |
Weilburg-Waldhausen, N/A D-35781
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@telefication.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
PJM
|
||||
1 | Equipment Product Code |
PRH200
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
E****** R********
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
+49 6********
|
||||
1 | Fax Number |
+49 6********
|
||||
1 |
e******@feig.de
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
FEIG ELECTRONIC GmbH
|
||||
1 | Name |
E**** R******
|
||||
1 | Physical Address |
Germany
|
||||
1 | Telephone Number |
49 64********
|
||||
app s | Non Technical Contact | |||||
1 | Firm Name |
FEIG ELECTRONIC GmbH
|
||||
1 | Name |
E****** R********
|
||||
1 | Physical Address |
Germany
|
||||
1 | Telephone Number |
49 64********
|
||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID Reader | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | Yes | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUEV NORD Hochfrequenztechnik GmbH Co. KG
|
||||
1 | Name |
T******** W******
|
||||
1 | Telephone Number |
0049-********
|
||||
1 | Fax Number |
0049-********
|
||||
1 |
h******@tuev-nord.de
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC