all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
Installation Manual | Users Manual | 340.86 KiB | ||||
1 2 |
|
Users Manual | Users Manual | 5.56 MiB | ||||
1 2 | Cover Letter(s) | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | External Photos | |||||||
1 2 | External Photos | |||||||
1 2 | Internal Photos | |||||||
1 2 | Internal Photos | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | Test Report | |||||||
1 2 | Test Report | |||||||
1 2 | Test Report | |||||||
1 2 | Test Report | |||||||
1 2 | Test Setup Photos | |||||||
1 2 | Test Setup Photos | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | External Photos | |||||||
1 2 | Internal Photos | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | RF Exposure Info | |||||||
1 2 | External Photos | |||||||
1 2 | Test Report | |||||||
1 2 | Test Setup Photos |
1 2 | Installation Manual | Users Manual | 340.86 KiB |
OBID i-scan MONTAGE INSTALLATION ID ISC.MRU200 MidRange Reader UHF
(deutsch / english) final public (B) 2007-12-20 M70201-0de-ID-B.doc H C S T U E D H S I L G N E OBID i-scan Montage ID ISC.MRU200 deutsche Version ab Seite 3 english version from page 30 FEIG ELECTRONIC GmbH Seite 2 von 53 M70201-0de-ID-B.doc OBID i-scan Montage Hinweis Copyright 2007 by FEIG ELECTRONIC GmbH Lange Strae 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de ID ISC.MRU200 H C S T U E D Alle frheren Ausgaben verlieren mit dieser Ausgabe ihre Gltigkeit. Die Angaben in diesem Dokument knnen ohne vorherige Ankndigung gendert werden. Weitergabe sowie Vervielfltigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte fr den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten. Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung fr die Richtigkeit und Vollstndigkeit der An-
gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht fr Folgeschden auf Grund fehlerhafter oder unvollstndiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bem-
hungen nie vollstndig vermeiden lassen, sind wir fr Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von gnstigsten Rahmenbedingun-
gen aus. FEIG ELECTRONIC GmbH bernimmt keine Gewhr fr die einwandfreie Funktion in systemfrem-
den Umgebungen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung dafr, dass die in diesem Dokument enthal-
tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte. OBID und OBID i-scan ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH FEIG ELECTRONIC GmbH Seite 3 von 53 M70201-0de-ID-B.doc H C S T U E D OBID i-scan Montage Inhalt ID ISC.MRU200 1 2 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Leistungsmerkmale 6 7 2.1 2.2 Verfgbare Readertypen...............................................................................................7 Lieferumfang..................................................................................................................7 3 Montage 8 3.1 3.2 3.3 3.4 Kabelverschraubungen.................................................................................................8 Dichtverschlsse...........................................................................................................9 Deckelhalter ...................................................................................................................9 Designblenden.............................................................................................................10 4 Anschlussklemmen und -buchsen 11 4.1 4.2 Versorgungsspannung ...............................................................................................12 Antennenanschlsse ..................................................................................................13 4.3 Schnittstellen...............................................................................................................14 4.3.1 RS232-Schnittstelle.......................................................................................................14 4.3.2 RS485- / RS422-Schnittstelle (ID ISC.MRU200-USB)..................................................15 4.3.3 Ethernet-Schnittstelle (ID ISC.MRU200-E)....................................................................16 4.3.4 USB-Schnittstelle (ID ISC.MRU200-USB).....................................................................17 4.4 Eingnge ......................................................................................................................17 4.5 Ausgnge .....................................................................................................................19 4.5.1 Optokoppler...................................................................................................................19 4.5.2 Relais ............................................................................................................................20 5 Bedien- und Anzeigeelemente 21 5.1 LEDs .............................................................................................................................21 FEIG ELECTRONIC GmbH Seite 4 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 5.2 5.3 5.4 T1: Reset-Taster ..........................................................................................................21 J1-J8: Schnittstellenkonfiguration.............................................................................22 X60: Default-Einstellung .............................................................................................23 6 Technische Daten 24 6.1 Zulassung ....................................................................................................................26 6.1.1 Europa (CE) ..................................................................................................................26 6.1.2 USA (FCC) ....................................................................................................................26 H C S T U E D FEIG ELECTRONIC GmbH Seite 5 von 53 M70201-0de-ID-B.doc C S T U E D OBID i-scan Montage ID ISC.MRU200 H 1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Das Gert darf nur fr den vom Hersteller vorgesehenen Zweck verwendet werden. Beim Aufstellen des Gertes im Geltungsbereich der FCC 47 CFR Part 15 ist ein Mindestabstand von 20 cm zwischen Antenne und menschlichem Krper zu gewhrleisten. Die Bedienungsanleitung ist zugriffsfhig aufzubewahren und jedem Benutzer auszuhndigen. Unzulssige Vernderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen, die nicht vom Hersteller des Gertes verkauft oder empfohlen werden, knnen Brnde, elektrische Schlge und Verletzungen verursachen. Solche Manahmen fhren daher zu einem Ausschluss der Haftung und der Hersteller bernimmt keine Gewhrleistung. Fr das Gert gelten die Gewhrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs gltigen Fassung. Fr eine ungeeignete, falsche manuelle oder automatische Einstellung von Parametern fr ein Gert bzw. ungeeignete Verwendung eines Gertes wird keine Haftung bernommen. Reparaturen drfen nur vom Hersteller durchgefhrt werden. Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gert drfen nur von Elektrofachkrften mit einschlgiger Ausbildung erfolgen. Alle Arbeiten am Gert und dessen Aufstellung mssen in bereinstimmung mit den nationalen elektrischen Bestimmungen und den rtlichen Vorschriften durchgefhrt werden. Beim Arbeiten an dem Gert mssen die jeweils gltigen Sicherheitsvorschriften beachtet werden. Besonderer Hinweis fr Trger von Herzschrittmachern:
Obwohl dieses Gert die zulssigen Grenzwerte fr elektromagnetische Felder nicht berschreitet, sollten Sie einen Mindestabstand von 25 cm zwischen dem Gert und Ihrem Herzschrittmacher einhalten und sich nicht fr lngere Zeit in unmittelbarer Nhe des Gerts bzw. der Antenne aufhalten. FEIG ELECTRONIC GmbH Seite 6 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 2 Leistungsmerkmale Der Reader ist fr das Lesen von passiven Datentrgern, sogenannten Smart Labels, mit einer Betriebsfrequenz im UHF Bereich entwickelt. 2.1 Verfgbare Readertypen Folgende Readertypen sind z.Z. verfgbar:
Tabelle 2-1: Verfgbare Readertypen Readertyp ID ISC.MRU200-USB-EU ID ISC.MRU200-E-EU ID ISC.MRU200-USB-FCC ID ISC.MRU200-E-FCC Beschreibung Reader mit USB-Schnittstelle fr Europa Reader mit Ethernet-Schnittstelle fr Europa Reader mit USB-Schnittstelle fr USA Reader mit Ethernet-Schnittstelle fr USA 2.2 Lieferumfang Folgende Komponenten sind im Lieferumfang enthalten:
1 x Reader ID ISC.MRU200 8 x Kurzschlussbrcke (Jumper) 2 x Dichtverschluss M16 1 x Dichtverschluss M12 1 x Dichtverschluss-Reduzierstck 2 x Designblenden aufsteckbar 2 x Integrierte Deckelhalter FEIG ELECTRONIC GmbH Seite 7 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 3 Montage C S T U E D Der Reader ist fr die Montage auf Wnden, auch im Freien, konzipiert. Zur Wandmontage befin-
den sich im Gehuse vorgesehene Lcher. Dazu muss das Gehuse nicht geffnet werden. (siehe Bild 3-1). 200 (7.87) 182 (7.16) 6
) 6 3
. 2
0 6
) 3 3 4
. 0 1 1 1 2 3 4 5 Bild 3-1: Gehuse ID ISC.MRU200 (alle Mae in mm (inch)) 3.1 Kabelverschraubungen Die einzelnen Kabelverschraubungen sind in Tabelle 3-1 aufgelistet:
Tabelle 3-1: Kabelverschraubungen ID ISC.MRU200 Kabel-
Verschraubung Gre 1 2 3 4 5 6 M 16 M 16 M 16 M 12 M 12 M 25 Klemmbereich
(in mm) 4,5...10 4,5...10 4,5...10 3,5...7 3,5...7 9...17 Beschreibung Anschlusskabel Antenne 1 Anschlusskabel Antenne 2 Eingnge / Relais / Ausgnge Schnittstelle (seriell) Spannungsversorgung Ethernet Interface (nur -E) / USB (nur -A) FEIG ELECTRONIC GmbH Seite 8 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 3.2 Dichtverschlsse Mit denen im Zubehr beigelegten Dichtverschlssen knnen nicht benutzte Kabelverschraubun-
gen verschlossen werden. Nur dann wird auch die Schutzart IP54 erreicht. Das beigelegte Dichtring-Reduzierstck ist fr die Netzwerkanbindung bzw. das USB-
Anschlusskabel vorgesehen. Das aufgeschlitzte Reduzierstck wird ber die Netzwerkleitung bzw. das USB-Anschlusskabel gelegt und anschlieend in der Kabelverschraubung fixiert. Bild 3-2: Netzwerkanbindung mit Dichtring-Reduzierstck 3.3 Deckelhalter Mit den beiden Deckelhaltern kann der Deckel an dem Gehuse fixiert werden. Die Deckelhalter werden in die dafr vorgesehenen ffnungen eingesteckt. Bild 3-3: Deckelhalter FEIG ELECTRONIC GmbH Seite 9 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 3.4 Designblenden C S T U E D Die Designblenden werden nach der Montage des Readers aufgesteckt. Die Nut an der Lngsseite der Blende dient zur Demontage der Blende. Mit einem geeigneten Schraubendreher kann die Blende entfernt werden. Bild 3-4: Designblende FEIG ELECTRONIC GmbH Seite 10 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 4 Anschlussklemmen und -buchsen In Bild 4-1 und Bild 4-2 sind alle Anschlussklemmen und -buchsen, sowie die Bedien- und Anzei-
geelemente fr die Readertypen -USB bzw. -E dargestellt. X1 VDCGND X8 D N G D x R D x T X2 D N G
A
B
Y
Z X3 1 J 8 J C 1 T U O E C 2 T U O E X4
1 N I
2 N I
X5 M O C C N 0 N X6 1 K 1 T 2 6 X X60 2 T N A 1 T N A 1 V 2 V 3 V 4 V Bild 4-1: Anschlussklemmen und -buchsen (Typ -A) FEIG ELECTRONIC GmbH Seite 11 von 53 M70201-0de-ID-B.doc H C S T U E D OBID i-scan Montage ID ISC.MRU200 D N G X1 VDCGND X7 Bild 4-2: Anschlussklemmen und -buchsen (Typ -E) 4.1 Versorgungsspannung Die Versorgungsspannung von 12...24 VDC wird an der Klemme X1 angeschlossen. Die Zulei-
tungslnge zwischen Netzteil und Reader-Modul darf 3 m nicht berschreiten. Tabelle 4-1: Pinbelegung Versorgungsspannung Klemme Kurzzeichen Beschreibung X1 / Pin 1 X1 / Pin 2 VDC GND VDC Versorgungsspannung (+) Ground Versorgungsspannung (-) GND VDC X1 Bild 4-3: Anschluss der Versorgungsspannung Bei dem verwendeten Netzteil sollte es sich um eine SELV-Stromquelle begrenzter Leistung han-
deln. Die Ausgangsleistung des Netzteils sollte min. 15 W betragen. Hinweis:
Eine Verpolung der Versorgungsspannung kann zur Zerstrung des Gertes fhren. FEIG ELECTRONIC GmbH Seite 12 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 4.2 Antennenanschlsse Der Anschluss der Antennen erfolgt ber die SMA-Buchsen ANT1 und ANT2. Das SWR der ange-
schlossen Antennen mit Kabel darf 1,5:1 nicht berschreiten. Tabelle 4-2: Antennenanschluss Anschluss ANT1, ANT2 Beschreibung SMA-Buchse fr Antennenanschluss
(Eingangsimpedanz 50 ) ANT1 ANT2 Bild 4-4: Antennenanschluss Hinweis:
Das maximale Anzugsdrehmoment der SMA-Buchsen betrgt 0,45 Nm. FEIG ELECTRONIC GmbH Seite 13 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 4.3 Schnittstellen C S T U E D 4.3.1 RS232-Schnittstelle Der Anschluss der RS232-Schnittstelle erfolgt ber X2. Die bertragungsparameter knnen per Softwareprotokoll konfiguriert werden. Tabelle 4-3: Pinbelegung RS232-Schnittstelle Klemme Kurzzeichen Beschreibung X2 / Pin 1 X2 / Pin 2 X2 / Pin 3 GND RxD TxD RS232 GND RS232 RxD RS232 TxD Reader X2 / Pin 1 (GND) X2 / Pin 2 (RxD) X2 / Pin 3 (TxD) 2 TxD RxD GND X PC Pin 5 Pin 3 Pin 2 9-pol. DUB-D-Buchse PC Bild 4-5: Verdrahtungsbeispiel fr den Anschluss der RS232-Schnittstelle FEIG ELECTRONIC GmbH Seite 14 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 4.3.2 RS485- / RS422-Schnittstelle (ID ISC.MRU200-USB) Die zweite asynchrone Schnittstelle kann als RS485 oder RS422 konfiguriert werden (siehe 5.3 J1-
J8: Schnittstellenkonfiguration ). Der Anschluss der RS485- bzw. RS422-Schnittstelle erfolgt ber X3. Tabelle 4-4 zeigt die Pinnbelegung fr die entsprechende Schnittstelle:
Tabelle 4-4: Pinbelegung RS485-/RS422-Schnittstelle Klemme Kurzzeichen Beschreibung X3 / Pin 1 X3 / Pin 2 X3 / Pin 3 X3 / Pin 4 X3 / Pin 5 GND RS485/RS422 GND A-
B+
Y-
Z+
RS485/RS422 (A -) RS485/RS422 (B +) RS422 (Y -) RS422 (Z +) Z+ Y-
B+ A- GND 3 X Bild 4-6: Anschlussbelegung der RS485-/RS422-Schnittstelle FEIG ELECTRONIC GmbH Seite 15 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 4.3.3 Ethernet-Schnittstelle (ID ISC.MRU200-E) C S T U E D Der Reader verfgt ber eine integrierte 10/100 base-T Netzwerkschnittstelle mit RJ-45- An-
schluss. Der Anschluss erfolgt ber X7. Bei einer strukturierten Verkabelung sollte Kabel der Kategorie 5 verwendet werden. Dies garan-
tiert einen problemlosen Betrieb bei 10 Mbps oder 100 Mbps. Tabelle 4-5: Pinbelegung Ethernet-Schnittstelle Klemme Kurzzeichen Beschreibung X7 / Pin 1 X7 / Pin 2 X7 / Pin 3 X7 / Pin 4 X7 / Pin 5 X7 / Pin 6 X7 / Pin 7 X7 / Pin 8 TX+
TX-
RX+
VETH+
VETH+
RX-
VETH-
VETH-
Transmit Data +
Transmit Data -
Receive Data +
n.c. n.c. Receive Data -
n.c. n.c. Vorraussetzung fr den Einsatz des TCP/IP-Protokolls ist, dass jedes Gert am Netzwerk ber eine eigene IP-Adresse verfgt. Alle Reader verfgen ber eine werksseitig voreingestellte IP-Adresse. Tabelle 4-6: Standardkonfiguration der Ethernet-Schnittstelle Netzwerk IP-Adresse Subnet-Mask Port Adresse 192.168.10.10 255.255.255.0 10001 Hinweis:
Die Reader mssen nacheinander ans Netzwerk angeschlossen und konfiguriert werden. Jede IP-Adresse darf nur einmal im Netzwerk vertreten sein. Alternativ kann die Einstellung ber die asynchrone Schnittstelle erfolgen. FEIG ELECTRONIC GmbH Seite 16 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 4.3.4 USB-Schnittstelle (ID ISC.MRU200-USB) Der Anschluss der USB-Schnittstelle erfolgt ber Buchse X8. Die Belegung ist genormt. Die Daten-
rate des Readers ist auf 12 Mbit beschrnkt (USB Full Speed). Es kann ein Standard-USB-Kabel verwendet werden. Hinweis:
Die maximale Lnge des USB-Kabels darf 5 m betragen. Lngere Kabel sind nicht erlaubt. 4.4 Eingnge Die Optokopplereingnge an Klemmleiste X5 sind galvanisch von der Reader-Elektronik getrennt und mssen daher mit einer externen Gleichspannung versorgt werden. Die Eingangs-LEDs der Optokoppler sind intern mit einem Serienwiderstand Rint von 500 beschaltet. Tabelle 4-7: Pinbelegung Optokopplereingnge Klemme Kurzzeichen Beschreibung X5 / Pin 1 X5 / Pin 2 X5 / Pin 3 X5 / Pin 4 IN1+
IN1-
IN2+
IN2-
+ Eingang 1
- Eingang 1
+ Eingang 2
- Eingang 2 X5
Rext Rext Rint IN2 Rint IN1 Uext Uext Bild 4-7: Interne und mgliche externe Beschaltung der Optokopplereingnge Bei Versorgungsspannungen grer 10 V muss der Eingangsstrom durch einen weiteren externen Vorwiderstand (siehe Tabelle 4-8) auf max. 20 mA begrenzt werden. FEIG ELECTRONIC GmbH Seite 17 von 53 M70201-0de-ID-B.doc H C S T U E D OBID i-scan Montage ID ISC.MRU200 Tabelle 4-8: Externe Vorwiderstnde Externe Spannung Uext Bentigter externer Vorwiderstand Rext 5...10 V 11...15 V 16...20 V 21...24 V
270 560 820 Hinweise:
Die Eingnge sind fr eine maximale Eingangsspannung von 24 VDC und einen Ein-
gangsstrom von maximal 20 mA ausgelegt. Verpolung oder berlastung der Eingnge fhrt zu deren Zerstrung. Die Versorgungsspannung des Readers darf nicht zur Ansteuerung der Eingnge ver-
wendet werden, da es ansonsten durch zustzlich eingestrahlte Strungen zu Einbuen in der Lesereichweite kommen kann. FEIG ELECTRONIC GmbH Seite 18 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 4.5 Ausgnge 4.5.1 Optokoppler Die Transistoranschlsse, Kollektor und Emitter, der beiden Optokopplerausgnge sind von der Reader-Elektronik galvanisch getrennt und ohne interne Zusatzbeschaltung an Klemme X4 nach auen gefhrt. Die Ausgnge mssen daher mit einer externen Spannung betrieben werden. Tabelle 4-9: Pinbelegung Optokopplerausgnge Klemme Kurzzeichen Beschreibung X4 / Pin 1 X4 / Pin 2 X4 / Pin 3 X4 / Pin 4 O1-C O1-E O2-C O2-E Kollektor Ausgang 1 Emitter Ausgang 1 Kollektor Ausgang 2 Emitter Ausgang 2 X4 E C E C OUT2 OUT1 Bild 4-8: Interne und mgliche externe Beschaltung der Optokopplerausgnge Hinweise:
Die Ausgnge sind fr max. 24 VDC / 30 mA ausgelegt. Verpolung oder berlastung der Ausgnge fhrt zu deren Zerstrung. Die Ausgnge sind nur zum Schalten ohmscher Lasten vorgesehen. FEIG ELECTRONIC GmbH Seite 19 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 4.5.2 Relais C S T U E D Als Relaisausgang steht an X6 ein Wechsler zur Verfgung. Tabelle 4-10: Pinbelegung Relaisausgang Klemme Kurzzeichen Beschreibung X6 / Pin 1 X6 / Pin 2 X6 / Pin 3 COM Arbeitskontakt NC NO ffner Schlieer X6 N0 NC COM Uext Bild 4-9: Interne und mgliche externe Beschaltung des Relaisausgangs Hinweise:
Der Relaisausgang ist fr max. 24 VDC / 2 A ausgelegt. Der Relaisausgang ist nur zum Schalten ohmscher Lasten vorgesehen. Im Falle einer induktiven Last sind die Relaiskontakte durch eine externe Schutzbeschaltung zu scht-
zen. FEIG ELECTRONIC GmbH Seite 20 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 5 Bedien- und Anzeigeelemente 5.1 LEDs In Tabelle 5-1 sind die Konfigurationen der einzelnen LEDs aufgelistet:
Tabelle 5-1: Konfiguration der LEDs Kurzzeichen Beschreibung LED V1 (grn)
"RUN-LED 1"
- Signalisiert den ordnungsgemen Ablauf der internen Reader-Software Diagnose 1: RF-Kommunikation / EEPROM-Status
- Signalisiert durch ein kurzes Blinken die fehlerfreie Kommunikation mit einem Transponder auf der RF-Schnittstelle LED V2 (blau)
- Blinkt abwechselnd mit V1 nach dem Reset im Anschluss an ein Software-Update LED V3 (gelb) LED V4 (rot)
- Blinkt abwechselnd mit V1 falls nach einem Reset ein Datenfehler beim Lesen der Parameter auftrat Diagnose 2: Host-Kommunikation
- Signalisiert durch ein kurzes Blinken das Senden eines Protokolls an den Host Diagnose 3: RF-Warnung
- Leuchtet bei einem Fehler im RF-Teil des Readers. Der Fehlertyp kann per Software ber die Schnittstellen ausgelesen werden 5.2 T1: Reset-Taster Durch Bettigen des Tasters T1 wird am Reader ein Reset durchgefhrt. FEIG ELECTRONIC GmbH Seite 21 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 5.3 J1-J8: Schnittstellenkonfiguration C S T U E D ber die Jumper J7 J8 kann die asynchrone Schnittstelle als RS485- oder RS422-Schnittstelle konfiguriert werden. Tabelle 5-2: Konfiguration der RS485-/RS422-Schnitstelle Jumper J7 J8 RS485 geschlossen geschlossen RS422 offen offen Es knnen die eventuell bentigten Abschlusswiderstnde mit den Jumpern J1 bis J6 zugeschaltet werden. Tabelle 5-3: Abschlusswiderstnde der RS485/RS422 Jumper Geschlossen offen J1 J2 J5 J3 J4 J6 Pull-Up an RS4xx -B Pull-Down an RS4xx -A Abschlusswiderstand RS4xx -A RS4xx -B Pull-Up an RS422 -Z Pull-Down an RS422 -Y Abschlusswiderstand RS422 -Y RS422 -Z ohne Pull-Up an RS4xx -B ohne Pull-Down an RS4xx -A ohne Abschlusswiderstand RS485 -A RS485 -B ohne Pull-Up an RS422 -Z ohne Pull-Down an RS422 -Y ohne Abschlusswiderstand RS422 -Y RS422 -Z 500 Ohm J1 J8 J7 500 Ohm 120 Ohm J5 J2 RS485 +
RS485 -
J3 500 J1 500 J6 120 J5 J4 500 120 J2 500 RS422 Z+
RS422 Y-
RS422 B+
RS422 A-
Bild 5-1: Jumper der RS485-Schnittstelle Bild 5-2: Jumper der RS422-Schnittstelle FEIG ELECTRONIC GmbH Seite 22 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 5.4 X60: Default-Einstellung Die Stiftleiste X60 kann mit einem Jumper (Rasterma 2,0 mm) kurzgeschlossen werden. In Tabelle 5-4 ist die Funktion der Stiftleiste X60 beschrieben. Tabelle 5-4: Stiftleiste X60 X60 offen kurzgeschlossen Beschreibung keine Auswirkung nach Bettigen des Tasters T1 wird die Werkseinstellung des Readers wieder eingestellt. Hinweis:
Alle vorgenommen Einstellungen gehen nach Bettigung des Tasters T1 in Verbindung mit kurzgeschlossener Stiftleiste X60 verloren. FEIG ELECTRONIC GmbH Seite 23 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 6 Technische Daten C S T U E D Mechanische Daten Gehuse Abmessungen (B x H x T) Gewicht Schutzart Farbe Elektrische Daten Spannungsversorgung Leistungsaufnahme Betriebsfrequenz Sendeleistung Modulationsgrad Empfnger Antennenanschlsse
- 2 x gemultiplext Ausgnge:
- 2 Optokoppler
- 1 Relais (1 x Wechsler) Eingnge
- 1 Optokoppler Schnittstellen Aluminium Druckguss, pulverbeschichtet, verschliebarer Klappdeckel 200 x 110 x 60 mm 1,1 kg IP 54 RAL 7040 (hnlich Fenstergrau) 12...24 VDC 5 %
Noise Ripple : max. 150 mV max. 15 VA 865,6...867,6 MHz (EN 302 208) 902...928 MHz (FCC CFR 47 Part 15.247) 100...300 mW (100 mW Step Software) 20...40% und 100%
(per Software einstellbar) Datenraten 40 kbps, 64 kbps, 80 kbps 2 x SMA Buchse (50 ) 24 VDC / 30 mA (galvanisch getrennt) 24 VDC / 2 A max. 24 VDC / 20 mA
- RS232
- RS485 / RS422 (wahlweise einstellbar)
- Ethernet (TCP/IP) (ID ISC.MRU200-E)
- USB (ID ISC.MRU200-A) FEIG ELECTRONIC GmbH Seite 24 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D Protokoll Modi Untersttzte Transponder Signalgeber optisch Multi-Reader-Betrieb
- FEIG ISO Host
- Buffer Reader Mode
(Data Filtering and buffering)
- Scan Mode
- EPC class 1 Gen 2
- 18000-6-B 4 LEDs zur Diagnose des Betriebszustandes
(UpgradeCode notwendig) Synchronisation der Luftprotokolle durch Ver-
wendung der Reader Synchronisation Umgebungsbedingungen Temperaturbereich
- Betrieb
- Lagerung Vibration Schock Angewendete Normen Zulassung Funk
- Europa
- USA EMV Sicherheit
- Niederspannung
- Human Exposure
-25...+55C
-25...+85C EN60068-2-6 10...150 Hz :
EN60068-2-27 Beschleunigung : 30 g 0,075 mm / 1 g EN 302 208 FCC 47 CFR Part 15 EN 301 489 EN 60950 EN 50364 FEIG ELECTRONIC GmbH Seite 25 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 6.1 Zulassung C S T U E D 6.1.1 Europa (CE) Die Funkanlage entspricht, bei bestimmungsgemer Verwendung den grundlegenden Anforde-
rungen des Artikels 3 und den brigen einschlgigen Bestimmungen der R&TTE Richtlinie 1999/5/EG vom Mrz 99. Equipment Classification gem ETSI EN 302 208 und ETSI EN 301 489: Class 2 6.1.2 USA (FCC) To meet the Part 15 of the FCC Rules the reader ID ISC.MRU200 must operate with the FEIG Antenna ID.ISC.ANT.U250/250-FCC. FCC ID: PJMMRU200 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. NOTICE:
Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FEIG ELECTRONIC GmbH Seite 26 von 53 M70201-0de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D FEIG ELECTRONIC GmbH Seite 27 von 53 M70201-0de-ID-B.doc H C S T U E D OBID i-scan Montage ID ISC.MRU200 FEIG ELECTRONIC GmbH Seite 28 von 53 M70201-0de-ID-B.doc H S I L G N E OBID i-scan Installation Note ID ISC.MRU200 Copyright 2007 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH. FEIG ELECTRONIC GmbH Page 30 of 53 M70201-0de-ID-B.doc OBID i-scan Installation Contents 1 2 Safety Instructions / Warning - Read before start-up !
Features of the Reader Family ID ISC.MRU200 ID ISC.MRU200 33 34 H S I L G N E 2.1 2.2 Available Reader Types ..............................................................................................34 Scope of delivery.........................................................................................................34 3 Installation 35 3.1 3.2 3.3 3.4 Cable Glands ...............................................................................................................35 Seal Caps .....................................................................................................................36 Cover stays ..................................................................................................................36 Decorative Covers.......................................................................................................37 4 Terminals and Jacks 38 4.1 4.2 Supply Voltage.............................................................................................................39 Antenna Connections .................................................................................................40 4.3 Interfaces .....................................................................................................................41 4.3.1 RS232 Interface ............................................................................................................41 4.3.2 RS485 / RS422 Interface (ID ISC.MRU200-USB).........................................................42 4.3.3 Ethernet Interface (ID ISC.MRU200-E) .........................................................................43 4.3.4 USB Interface (ID ISC.MRU200-USB) ..........................................................................44 4.4 Inputs............................................................................................................................44 4.5 Outputs.........................................................................................................................46 4.5.1 Optocouplers .................................................................................................................46 4.5.2 Relay .............................................................................................................................47 5 Operating and Display Elements 48 5.1 LEDs .............................................................................................................................48 FEIG ELECTRONIC GmbH Page 31 of 53 M70201-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 5.2 5.3 5.4 Reset Button ................................................................................................................48 J1-J8: Interface configuration ....................................................................................49 X60: Default Settings...................................................................................................50 6 Technical Data 51 6.1 Approval.......................................................................................................................53 6.1.1 Europe (CE) ..................................................................................................................53 6.1.2 USA (FCC) ....................................................................................................................53 FEIG ELECTRONIC GmbH Page 32 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 H S I L G N E 1 Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer. When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation of 20 cm (8 inch) between antenna and the human body must be maintained. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm (10 inch) between the device and your cardiac pace-
maker and not stay in the immediate proximity of the devices antenna for any length of time. FEIG ELECTRONIC GmbH Page 33 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 2 Features of the Reader Family ID ISC.MRU200 The Reader has been developed for reading passive data carriers, so-called Smart Labels, using an operating frequency in the UHF range. 2.1 Available Reader Types H S I L G N E The following Readers are currently available:
Table 2-1: Available Reader types Reader type ID ISC.MRU200-USB-EU ID ISC.MRU200-E-EU ID ISC.MRU200-USB-FCC ID ISC.MRU200-E-FCC Description Reader with USB Interface for Europe Reader with Ethernet Interface for Europe Reader with USB Interface for USA Reader with Ethernet-Interface for USA 2.2 Scope of delivery The following components are included in the scope of delivery:
1 x Reader ID ISC.MRU200 8 x jumper 2 x seal cap M16 1 x seal cap M12 1 x seal cap - reducer 2 x decorative cover, clip-on 2 x integrated cover stays FEIG ELECTRONIC GmbH Page 34 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 3 Installation The Reader is designed for wall mount, including outdoors. Holes are provided in the housing for wall attachment. The housing does not need to be opened for installation on a wall (see Fig. 3-1). 200 (7.87) 182 (7.16) H S I L G N E 6
) 6 3
. 2
0 6
) 3 3 4
. 0 1 1 1 2 3 4 5 Fig. 3-1: Housing ID ISC.MRU200 (all dimensions in mm (inch)) 3.1 Cable Glands The different cable glands are shown in Table 3-1. Table 3-1: ID ISC.MRU200 cable glands Cable gland 1 2 3 4 5 6 Size M 16 M 16 M 16 M 12 M 12 M 25 Clamping Range in mm (inch) 4,5...10 (0.18...0.39) 4,5...10 (0.18...0.39) 4,5...10 (0.18...0.39) 3,5...7 (0.14...0.28) 3,5...7 (0.14...0.28) 9...17 (0.35...0.67) Description Antenna Cable 1 Antenna Cable 2 Inputs / Relay / Outputs Interface (serial) Supply voltage Ethernet Interface (Model E only) USB Interface (Model USB only) FEIG ELECTRONIC GmbH Page 35 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 3.2 Seal Caps The seal caps included in the scope of delivery can be used to close off unused cable fittings. This is necessary for reaching the IP54 class. The reducing ring provided is intended for the network connection. The slotted reducer is placed over the network cable and then fixed in place in the cable gland. H S I L G N E Fig. 3-2: network connection with slotted reducer 3.3 Cover stays The two cover stays can be used to attach the cover to the housing. The cover stays are inserted into the openings provided for this purpose. Fig. 3-3: Cover stay FEIG ELECTRONIC GmbH Page 36 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 3.4 Decorative Covers The decorative covers are attached after installing the Reader. The slot on the long side of the cover is used for disassembling the cover. Use a screwdriver to remove the cover. H S I L G N E Fig. 3-4: Decorative cover FEIG ELECTRONIC GmbH Page 37 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 4 Terminals and Jacks Fig. 4-1 and Fig. 4-2 show terminals, jacks and operating elements of reader type -USB respec-
tively reader type -E. H S X1 VDCGND X8 I L G N E D N G D x R D x T X2 D N G
A
B
Y
Z X3 1 J 8 J C 1 T U O E C 2 T U O E X4
1 N I
2 N I
X5 M O C C N 0 N X6 1 K 1 T 2 6 X X60 2 T N A 1 T N A 1 V 2 V 3 V 4 V Fig. 4-1: Terminals, jacks and operating elements of Type -USB FEIG ELECTRONIC GmbH Page 38 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 D N G X1 VDCGND X7 H S I L G N E Fig. 4-2: Terminals, jacks and operating elements of Type -E 4.1 Supply Voltage Connect the 12...24 VDC supply voltage to Terminal X1. The cable length between the power supply and the Reader module must not exceed 3m (118 inch). Table 4-1: Supply voltage pin assignments Terminal Abbreviation Description X1 / Pin 1 X1 / Pin 2 VDC GND Vcc supply voltage (+) Ground supply voltage (-) GND VDC X1 Fig. 4-3: Connecting the supply voltage The power supply should be a Safety Extra-Low Voltage (SELV) type with limited power. The out-
put power of the power supply should be at least 15 W. Note:
Reversing the polarity of the supply voltage may destroy the unit. FEIG ELECTRONIC GmbH Page 39 of 53 M70201-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 4.2 Antenna Connections The external antennas are connected to the SMA jacks ANT1 and ANT2. The SWR of the con-
nected antennas with the cables should not be worse than 1.5:1. Table 4-2: Antenna Connections ANT1 and ANT2 Connections ANT1, ANT2 Description SMA jacks for antenna connections
(input impedance 50 ) ANT1 ANT2 Fig. 4-4: Antenna Connections ANT1 and ANT2 Note:
The maximum tightening torque of the SMA sockets is 0,45 Nm (4.0 lbf in). FEIG ELECTRONIC GmbH Page 40 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 4.3 Interfaces 4.3.1 RS232 Interface The RS232 interface is connected on X2. The transmission parameters can be configured by means of software protocol. H S I L G N E Table 4-3: RS232 interface pinouts Terminal Abbreviation Description X2 / Pin 1 X2 / Pin 2 X2 / Pin 3 GND RxD TxD RS232 GND RS232 RxD RS232 TxD Reader X2 / Pin 1 (GND) X2 / Pin 2 (RxD) X2 / Pin 3 (TxD) PC Pin 5 Pin 3 Pin 2 2 TxD RxD GND X 9-pol. DUB-D-Buchse PC Fig. 4-5: Wiring example for connecting the RS232 interface FEIG ELECTRONIC GmbH Page 41 of 53 M70201-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 4.3.2 RS485 / RS422 Interface (ID ISC.MRU200-USB) The second asynchronous interface can be configured for RS485 or RS422 (see 5.3 J1-J8: Inter-
face configuration). The RS485 interface respectively RS422 interface is connected to X3. Table 4-4: RS485 / RS422 interface pinouts Terminal Abbreviation Description X3 / Pin 1 X3 / Pin 2 X3 / Pin 3 X3 / Pin 4 X3 / Pin 5 GND RS485 / RS422 GND A-
B+
Y-
Z+
RS485 / RS422 (A -) RS485 / RS422 (B +) RS422 (Y -) RS422 (Z +) Z+ Y-
B+ A- GND 3 X Fig. 4-6: Wiring the RSR485 / RS422 interface FEIG ELECTRONIC GmbH Page 42 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 4.3.3 Ethernet Interface (ID ISC.MRU200-E) The Reader has an integrated 10 / 100 base-T network port for an RJ45. Connection is made on X7. With structured cabling Cat 5 cables should be used. This ensures reliable operation at 10 Mbps or 100 Mbps. Table 4-5: Ethernet interface pinouts Terminal Abbreviation Description X7 / Pin 1 X7 / Pin 2 X7 / Pin 3 X7 / Pin 4 X7 / Pin 5 X7 / Pin 6 X7 / Pin 7 X7 / Pin 8 TX+
TX-
RX+
VETH+
VETH+
RX-
VETH-
VETH-
Transmit Data +
Transmit Data -
Receive Data +
n.c. n.c. Receive Data -
n.c. n.c. H S I L G N E The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address.. Table 4-6: Standard configuration of the Ethernet connection Network IP-Address Subnet-Mask Port Address 192.168.10.10 255.255.255.0 10001 Note:
The readers must be connected to the network and configured one after the other. Every IP-
Address must be used only one time. Alternatively this configuration can be done with the asynchronous interface. FEIG ELECTRONIC GmbH Page 43 of 53 M70201-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 4.3.4 USB Interface (ID ISC.MRU200-USB) The USB socket on the board is terminal X8. The pinout is standardized. The data rate is reduced to 12 Mbit (USB full speed). A standard USB-cable can be used. Note:
The length of the USB-cable can be a max. of 5m (20 inch). It is not allowed to use longer cables. 4.4 Inputs The optocoupler inputs in Terminal X5 are galvanically isolated from the Reader electronics and must therefore be externally supplied. The input LEDs for the optocouplers are switch internally with a series resistor Rint of 500 . Table 4-7: Optocoupler input pin assignments Terminal Abbreviation Description X5 / Pin 1 X5 / Pin 2 X5 / Pin 3 X5 / Pin 4 IN1+
IN1-
IN2+
IN2-
+ Input 1
- Input 1
+ Input 2
- Input 2 X5
Rext Rext Rint IN2 Rint IN1 Uext Uext Fig. 4-7: Internal and possible external wiring of the optocoupler inputs For supply voltages of greater than 10 V the input current must be limited to max. 20 mA by an additional external series resistor (see Table 4-8). FEIG ELECTRONIC GmbH Page 44 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 Table 4-8: External Series Resistor External voltage Uext Required external series resistor Rext 5...10 V 11...15 V 16...20 V 21...24 V
270 560 820 H S Notes:
The inputs are configured for a maximum input current of 24 VDC and an input current of maximum 20 mA. Reversing the polarity or overloading the inputs will destroy them. The Reader supply voltage must not be used to drive the inputs, since otherwise additionally induced noise may reduce the effective reading range. I L G N E FEIG ELECTRONIC GmbH Page 45 of 53 M70201-0de-ID-B.doc Installation ID ISC.MRU200 OBID i-scan 4.5 Outputs 4.5.1 Optocouplers The transistor connections of the two optocoupler outputs, collector and emitter, are galvanically isolated from the Reader electronics and brought out with no internal circuitry to terminal X4. The outputs must therefore be powered with an external power supply. H S I L G N E Table 4-9: Optocoupler output pin configuration Terminal Abbreviation Description X4 / Pin 1 X4 / Pin 2 X4 / Pin 3 X4 / Pin 4 O1-C O1-E O2-C O2-E Collector Output 1 Emitter Output 1 Collector Output 2 Emitter Output 2 X4 E C E C OUT2 OUT1 Fig. 4-8: Internal and possible external wiring of the optocoupler outputs Notes:
The outputs are configured for max. 24 VDC / 30 mA. Reversing the polarity or overloading the outputs will destroy them. The outputs are intended for switching resistive loads only. FEIG ELECTRONIC GmbH Page 46 of 53 M70201-0de-ID-B.doc OBID i-scan 4.5.2 Relay Installation ID ISC.MRU200 A changeover relay is provided on terminal X6. Table 4-10: Relay output pinouts Terminal Abbreviation Description H S I L G N E X6 / Pin 1 X6 / Pin 2 X6 / Pin 3 COM Working contact NC NO Normally closed Normally open X6 N0 NC COM Uext Fig. 4-9: Internal and possible external wiring of the relay output Notes:
The relay outputs are configured for max. 24 VDC / 2 A. The relay outputs are intended for switching resistive loads only. If an inductive load is used, the relay contacts must be protected by means of an external protection circuit. FEIG ELECTRONIC GmbH Page 47 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 5 Operating and Display Elements 5.1 LEDs Table 5-1 shows the LED configuration. H S I L G N E Table 5-1: LED configuration Abbreviation LED V1 (green) LED V2 (blue) Description Indicates proper running of the internal Reader software
"RUN-LED 1"
Diagnostic 1: RF communication / EEPROM status
- Short flashing indicates errorless communication with a transponder on the RF interface
- Flashes alternately with V1 after a reset following a software update
- Flashes alternately with V1 in case of a data error when reading the parameters after a reset LED V3 (yellow) Diagnostic 2: Host communication
- Short flashing indicates sending of a protocol to the host LED V4 (red) Diagnostic 4: RF warning
- Comes on when there is an error in the RF section of the Reader. The error type can be read out via software over the RS232/RS485 interface 5.2 Reset Button Pressing the button T1 resets the reader. FEIG ELECTRONIC GmbH Page 48 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 5.3 J1-J8: Interface configuration Jumpers J7 and J8 are used to configure the asynchronous interface as an RS485 or R422 port. H S I L G N E Table 5-2: Configuration of the RS485 / RS422 port Jumper J7 J8 RS485 closed closed RS422 open open Any termination resistors needed can be enabled using jumpers J1 through J6. Table 5-3: Termination resistors for RS485 / RS422 Jumper closed open J1 J2 J5 J3 J4 J6 Pull-Up on RS4xx - B Pull-Down on RS4xx - A Termination resistor RS4xx - A RS4xx - B Pull-Up on RS422 - Z without Pull-Up on RS4xx - B without Pull-Down on RS4xx A without Termination resistor RS485 - A RS485 - B without Pull-Up on RS422 - Z Pull-Down on RS422 - Y without Pull-Down on RS422 Y Termination resistor RS422 - Y RS422 - Z without Termination resistor RS422 - Y RS422 - Z 500 Ohm J1 J8 J7 500 Ohm 120 Ohm J5 J2 RS485 +
RS485 -
J3 500 J1 500 J6 120 J5 J4 500 120 J2 500 RS422 Z+
RS422 Y-
RS422 B+
RS422 A-
Fig. 5-1: RS485 Interface Jumper Fig. 5-2: RS422 Interface Jumper FEIG ELECTRONIC GmbH Page 49 of 53 M70201-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 5.4 X60: Default Settings The pin connector X60 can be closed with a jumper (2.0 mm). Table 5-4: pin connector X60 X60 open closed Description no effect after pressing the button T1 the reader is configured with the default settings. Note:
All configured settings are lost after pressing the button while the pin connector X60 is closed. FEIG ELECTRONIC GmbH Page 50 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 H S I L G N E 6 Technical Data Mechanical Data Housing Dimensions ( W x H x D ) Weight Die-case aluminum, powder coated, lockable hinged cover 200 x 110 x 60 mm
(7.9 inch x 4.3 inch x 2.4 inch) approx. 1,1 kg (2.4 lb) Enclosure rating IP 54 Color RAL 7040 (similar to window gray) Electrical Data Supply Voltage Power Consumption Operating Frequency Transmitting Power Modulation Receiver Antenna Connection
- 2 x multiplexing Outputs:
- 2 Optocouplers
- 1 Relay (1 x Changeover) Inputs
- 2 Optocouplers 12...24 VDC 5 %
Noise Ripple : max. 150 mV max. 15 VA 869.525 MHz (EN 300 220) 865.6...867.6 MHz (EN 302 208) 902...928 MHz (FCC CFR 47 Part 15.247) 100...300 mW (100 mW Step Software) 20...40% and 100%
(software configurable) Data rates 40 kbps, 64 kbps, 80 kbps 2 x SMA socket (50 ) 24 VDC / 30 mA (galvanically isolated) 24 VDC / 2 A max. 24 VDC / 20 mA (galvanically isolated) FEIG ELECTRONIC GmbH Page 51 of 53 M70201-0de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 Interfaces Protocol modes Supported Transponders Optical Indicators Multi-Reader Operation
- RS232
- RS485 / RS422 (selectable)
- Ethernet (TCP/IP) (ID ISC.MRU200-E only)
- USB (ID ISC.MRU200-USB only)
- FEIG ISO Host
- Buffer Reader Mode
(Data Filtering and buffering)
- Scan Mode
- EPC class 1 Gen 2
- 18000-6-B 4 LEDs for operating status diagnostics
(UpgradeCode required) Synchronization of the air protocols using Reader synchronization Ambient Temperature range
- Operating
- Storage Vibration Shock Applicable Standards RF approval
- Europe
- USA EMC Safety
- Low-Voltage
- Human Exposure
-25...+55C (-13...+131F)
-25...+85C (-13...+185F) EN60068-2-6 10...150 Hz :
EN60068-2-27 Acceleration 0.075 mm / 1 g
: 30 g EN 302 208 / EN 300 220 FCC 47 CFR Part 15 EN 301 489 EN 60950 EN 50364 FEIG ELECTRONIC GmbH Page 52 of 53 M70201-0de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 6.1 Approval 6.1.1 Europe (CE) When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99. H S I L G N E Equipment Classification according to ETSI EN 302 208 and ETSI EN 301 489: Class 2 6.1.2 USA (FCC) To meet the Part 15 of the FCC Rules the reader ID ISC.MRU200 must operate with the FEIG Antenna ID.ISC.ANT.U250/250-FCC. FCC ID: PJMMRU200 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. NOTICE:
Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FEIG ELECTRONIC GmbH Page 53 of 53 M70201-0de-ID-B.doc
1 2 | Users Manual | Users Manual | 5.56 MiB |
OBID i-scan MONTAGE INSTALLATION ID ISC.MRU200 MidRange Reader UHF
(deutsch / english) preliminary public (B) 2009-07-24 M70201-2de-ID-B.doc H C S T U E D OBID i-scan Montage ID ISC.MRU200 FEIG ELECTRONIC GmbH Seite 2 von 54 M70201-2de-ID-B.doc H S I L G N E OBID i-scan Montage ID ISC.MRU200 deutsche Version ab Seite 4 english version from page 30 H C S T U E D FEIG ELECTRONIC GmbH Seite 3 von 54 M70201-2de-ID-B.doc H C S T U E D OBID i-scan Montage Hinweis Copyright 2007/2008 by FEIG ELECTRONIC GmbH Lange Strae 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de ID ISC.MRU200 Alle frheren Ausgaben verlieren mit dieser Ausgabe ihre Gltigkeit. Die Angaben in diesem Dokument knnen ohne vorherige Ankndigung gendert werden. Weitergabe sowie Vervielfltigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrcklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle Rechte fr den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten. Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung fr die Richtigkeit und Vollstndigkeit der An-
gaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht fr Folgeschden auf Grund fehlerhafter oder unvollstndiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bem-
hungen nie vollstndig vermeiden lassen, sind wir fr Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von gnstigsten Rahmenbedingun-
gen aus. FEIG ELECTRONIC GmbH bernimmt keine Gewhr fr die einwandfreie Funktion in systemfrem-
den Umgebungen. FEIG ELECTRONIC GmbH bernimmt keine Gewhrleistung dafr, dass die in diesem Dokument enthal-
tenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte. OBID und OBID i-scan ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH FEIG ELECTRONIC GmbH Seite 4 von 54 M70201-2de-ID-B.doc ID ISC.MRU200 H C S T U E D OBID i-scan Montage Inhalt 1 2 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Leistungsmerkmale 7 8 2.1 2.2 Verfgbare Readertypen.............................................................................................8 Lieferumfang ...............................................................................................................8 3 Montage 9 3.1 3.2 3.3 3.4 Kabelverschraubungen ............................................................................................10 Dichtverschlsse ......................................................................................................10 Deckelhalter...............................................................................................................11 Designblenden ..........................................................................................................11 4 Anschlussklemmen und -buchsen 12 4.1 4.2 Versorgungsspannung.............................................................................................13 Antennenanschlsse ................................................................................................14 4.3 Schnittstellen ............................................................................................................15 4.3.1 RS232-Schnittstelle.....................................................................................................15 4.3.2 RS485- / RS422-Schnittstelle (ID ISC.MRU200-USB).................................................16 4.3.3 Ethernet-Schnittstelle (ID ISC.MRU200-E)..................................................................17 4.3.4 USB-Schnittstelle (ID ISC.MRU200-USB) ...................................................................18 4.4 Eingnge....................................................................................................................18 4.5 Ausgnge...................................................................................................................20 4.5.1 Optokoppler ................................................................................................................20 4.5.2 Relais..........................................................................................................................21 5 Bedien- und Anzeigeelemente 22 5.1 5.2 LEDs...........................................................................................................................22 T1: Reset-Taster........................................................................................................22 FEIG ELECTRONIC GmbH Seite 5 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 5.3 C 5.4 S T U E D 6 6.1 J1-J8: Schnittstellenkonfiguration...........................................................................23 X62: Bootloader Modus ............................................................................................24 Technische Daten 25 Zulassung..................................................................................................................27 6.1.1 Europa (CE)................................................................................................................27 6.1.2 USA (FCC)..................................................................................................................27 6.1.3 USA und Kanada (UL) ................................................................................................28 FEIG ELECTRONIC GmbH Seite 6 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 1 Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Das Gert darf nur fr den vom Hersteller vorgesehenen Zweck verwendet werden. Beim Aufstellen des Gertes im Geltungsbereich der FCC 47 CFR Part 15 ist ein Mindestabstand von 20 cm zwischen Antenne und menschlichem Krper zu gewhrleisten. Die Bedienungsanleitung ist zugriffsfhig aufzubewahren und jedem Benutzer auszuhndigen. Unzulssige Vernderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen, die nicht vom Hersteller des Gertes verkauft oder empfohlen werden, knnen Brnde, elektrische Schlge und Verletzungen verursachen. Solche Manahmen fhren daher zu einem Ausschluss der Haftung und der Hersteller bernimmt keine Gewhrleistung. Fr das Gert gelten die Gewhrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs gltigen Fassung. Fr eine ungeeignete, falsche manuelle oder automatische Einstellung von Parametern fr ein Gert bzw. ungeeignete Verwendung eines Gertes wird keine Haftung bernommen. Reparaturen drfen nur vom Hersteller durchgefhrt werden. Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gert drfen nur von Elektrofachkrften mit einschlgiger Ausbildung erfolgen. Alle Arbeiten am Gert und dessen Aufstellung mssen in bereinstimmung mit den nationalen elektrischen Bestimmungen und den rtlichen Vorschriften durchgefhrt werden. Beim Arbeiten an dem Gert mssen die jeweils gltigen Sicherheitsvorschriften beachtet werden. Besonderer Hinweis fr Trger von Herzschrittmachern:
Obwohl dieses Gert die zulssigen Grenzwerte fr elektromagnetische Felder nicht berschreitet, sollten Sie einen Mindestabstand von 25 cm zwischen dem Gert und Ihrem Herzschrittmacher einhalten und sich nicht fr lngere Zeit in unmittelbarer Nhe des Gerts bzw. der Antenne aufhalten. FEIG ELECTRONIC GmbH Seite 7 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 2 Leistungsmerkmale C S T U E D Der Reader ist fr das Lesen von passiven Datentrgern, sogenannten Smart Labels, mit einer Betriebsfrequenz im UHF Bereich entwickelt. 2.1 Verfgbare Readertypen Folgende Readertypen sind z.Z. verfgbar:
Tabelle 2-1: Verfgbare Readertypen Readertyp ID ISC.MRU200-USB-EU ID ISC.MRU200-E-EU ID ISC.MRU200-USB-FCC ID ISC.MRU200-E-FCC Beschreibung Reader mit USB-Schnittstelle fr Europa Reader mit Ethernet-Schnittstelle fr Europa Reader mit USB-Schnittstelle fr USA Reader mit Ethernet-Schnittstelle fr USA 2.2 Lieferumfang Folgende Komponenten sind im Lieferumfang enthalten:
1 x Reader ID ISC.MRU200 8 x Kurzschlussbrcke (Jumper) 2 x Dichtverschluss M16 1 x Dichtverschluss M12 1 x Dichtverschluss-Reduzierstck 2 x Designblenden aufsteckbar 2 x Integrierte Deckelhalter FEIG ELECTRONIC GmbH Seite 8 von 54 M70201-2de-ID-B.doc H C S T U E D OBID i-scan 3 Montage Montage ID ISC.MRU200 Der Reader ist fr die Montage auf Wnden konzipiert. Zur Wandmontage befinden sich vier im Gehuse vorgesehene Lcher (d=7mm, Ma 60mmx182mm). Dazu muss das Gehuse nicht ge-
ffnet werden. (siehe Bild 3-1). Die Gre und Art der Schrauben und Befestigungsdbel hngt stark von der Festigkeit des Untergrundes ab. Die Dbel und Schrauben sollten mindestens eine zulssige Last von 1.5 kN fr alle Belastungsrichtungen aushalten (Untergrund Stahl z.B. Zylinder-
schraube M5 Stahl verzinkt DIN 84 / ISO 1207, Festigkeitskasse 8.8 oder Beton, Stein z.B. Kunst-
stoffdbel 6mm mit Holzschraube DIN96 d=4mm). Der maximale Schraubenkopfdurchmesser be-
trgt 8,5 mm 200 (7.87) 182 (7.16) 6
) 6 3
. 2
0 6
) 3 3
. 4
0 1 1 1 2 3 4 5 Bild 3-1: Gehuse ID ISC.MRU200 (alle Mae in mm (inch)) FEIG ELECTRONIC GmbH Seite 9 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 3.1 Kabelverschraubungen C S T U E D Die einzelnen Kabelverschraubungen sind in Tabelle 3-1 aufgelistet:
Tabelle 3-1: Kabelverschraubungen ID ISC.MRU200 Kabel-
Verschraubung Gre 1 2 3 4 5 6 M 16 M 16 M 16 M 12 M 12 M 25 3.2 Dichtverschlsse Klemmbereich
(in mm) 4,5...10 4,5...10 4,5...10 3,5...7 3,5...7 9...17 Beschreibung Anschlusskabel Antenne 1 Anschlusskabel Antenne 2 Eingnge / Relais / Ausgnge Schnittstelle (seriell) Spannungsversorgung Ethernet Interface (nur -E) / USB (nur -A) Mit denen im Zubehr beigelegten Dichtverschlssen knnen nicht benutzte Kabelverschraubun-
gen verschlossen werden. Nur dann wird auch die Schutzart IP54 erreicht. Das beigelegte Dichtring-Reduzierstck ist fr die Netzwerkanbindung bzw. das USB-
Anschlusskabel vorgesehen. Das aufgeschlitzte Reduzierstck wird ber die Netzwerkleitung bzw. das USB-Anschlusskabel gelegt und anschlieend in der Kabelverschraubung fixiert. Bild 3-2: Netzwerkanbindung mit Dichtring-Reduzierstck FEIG ELECTRONIC GmbH Seite 10 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 3.3 Deckelhalter Mit den beiden Deckelhaltern kann der Deckel an dem Gehuse fixiert werden. Die Deckelhalter werden in die dafr vorgesehenen ffnungen eingesteckt. H C S T U E D Bild 3-3: Deckelhalter 3.4 Designblenden Die Designblenden werden nach der Montage des Readers aufgesteckt. Die Nut an der Lngsseite der Blende dient zur Demontage der Blende. Mit einem geeigneten Schraubendreher kann die Blende entfernt werden. Bild 3-4: Designblende FEIG ELECTRONIC GmbH Seite 11 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 4 Anschlussklemmen und -buchsen C S T U E D In Bild 4-1 und Bild 4-2 sind alle Anschlussklemmen und -buchsen, sowie die Bedien- und Anzei-
geelemente fr die Readertypen -USB bzw. -E dargestellt. X1 VDCGND X8 D N G D x R D x T X2 D N G
A
B
Y
Z X3 1 J 8 J C 1 T U O E C 2 T U O E X4
1 N I
2 N I
X5 M O C C N 0 N X6 1 K 1 T 2 6 X 2 T N A 1 T N A 1 V 2 V 3 V 4 V Bild 4-1: Anschlussklemmen und -buchsen (Typ -A) FEIG ELECTRONIC GmbH Seite 12 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D D N G X1 VDCGND X7 Bild 4-2: Anschlussklemmen und -buchsen (Typ -E) 4.1 Versorgungsspannung Die Versorgungsspannung von 12...24 VDC leitungslnge zwischen Netzteil und Reader-Modul darf 3 m nicht berschreiten. Tabelle 4-1: Pinbelegung Versorgungsspannung wird an der Klemme X1 angeschlossen. Die Zu-
Klemme Kurzzeichen Beschreibung X1 / Pin 1 X1 / Pin 2 VDC GND VDC Versorgungsspannung (+) Ground Versorgungsspannung (-) GND VDC X1 Bild 4-3: Anschluss der Versorgungsspannung Die Ausgangsleistung des Netzteils sollte min. 15 W betragen. Bei allen Installation nach UL 60950 bzw. EN 60950 gilt:
Das Gert muss mit einem Listed NEC Class 2/LPS Netzteil versorgt werden Bei Anschluss der Gerte mit flexiblen Leitungen sind im besondern die Vorschriften nach NEC Artikel 400.7 (8) und Artikel 400.8 (1) (7) Anzuwenden. Hinweis:
Eine Verpolung der Versorgungsspannung kann zur Zerstrung des Gertes fhren. FEIG ELECTRONIC GmbH Seite 13 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 4.2 Antennenanschlsse C S T U E D Der Anschluss der Antennen erfolgt ber die SMA-Buchsen ANT1 und ANT2. Das SWR der ange-
schlossen Antennen mit Kabel darf 1,5:1 nicht berschreiten. Tabelle 4-2: Antennenanschluss Anschluss ANT1, ANT2 Beschreibung SMA-Buchse fr Antennenanschluss
(Eingangsimpedanz 50 ) ANT1 ANT2 Bild 4-4: Antennenanschluss Hinweis:
Das maximale Anzugsdrehmoment der SMA-Buchsen betrgt 0,45 Nm. FEIG ELECTRONIC GmbH Seite 14 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 4.3 Schnittstellen 4.3.1 RS232-Schnittstelle Der Anschluss der RS232-Schnittstelle erfolgt ber X2. Die bertragungsparameter knnen per Softwareprotokoll konfiguriert werden. Tabelle 4-3: Pinbelegung RS232-Schnittstelle Klemme Kurzzeichen Beschreibung X2 / Pin 1 X2 / Pin 2 X2 / Pin 3 GND RxD TxD RS232 GND RS232 RxD RS232 TxD Reader X2 / Pin 1 (GND) X2 / Pin 2 (RxD) X2 / Pin 3 (TxD) 2 TxD RxD GND X PC Pin 5 Pin 3 Pin 2 9-pol. DUB-D-Buchse PC Bild 4-5: Verdrahtungsbeispiel fr den Anschluss der RS232-Schnittstelle FEIG ELECTRONIC GmbH Seite 15 von 54 M70201-2de-ID-B.doc C S T U E D OBID i-scan Montage ID ISC.MRU200 H 4.3.2 RS485- / RS422-Schnittstelle (ID ISC.MRU200-USB) Die zweite asynchrone Schnittstelle kann als RS485 oder RS422 konfiguriert werden (siehe 5.3 J1-
J8: Schnittstellenkonfiguration ). Der Anschluss der RS485- bzw. RS422-Schnittstelle erfolgt ber X3. Tabelle 4-4 zeigt die Pinnbelegung fr die entsprechende Schnittstelle:
Tabelle 4-4: Pinbelegung RS485-/RS422-Schnittstelle Klemme Kurzzeichen Beschreibung X3 / Pin 1 X3 / Pin 2 X3 / Pin 3 X3 / Pin 4 X3 / Pin 5 GND A-
B+
Y-
Z+
RS485/RS422 GND RS485/RS422 (A -) RS485/RS422 (B +) RS422 (Y -) RS422 (Z +) Z+ Y-
B+ A- GND 3 X Bild 4-6: Anschlussbelegung der RS485-/RS422-Schnittstelle FEIG ELECTRONIC GmbH Seite 16 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 4.3.3 Ethernet-Schnittstelle (ID ISC.MRU200-E) Der Reader verfgt ber eine integrierte 10/100 base-T Netzwerkschnittstelle mit RJ-45- An-
schluss. Der Anschluss erfolgt ber X7. Bei einer strukturierten Verkabelung sollte Kabel der Kategorie 5 verwendet werden. Dies garan-
tiert einen problemlosen Betrieb bei 10 Mbps oder 100 Mbps. Tabelle 4-5: Pinbelegung Ethernet-Schnittstelle Klemme Kurzzeichen Beschreibung X7 / Pin 1 X7 / Pin 2 X7 / Pin 3 X7 / Pin 4 X7 / Pin 5 X7 / Pin 6 X7 / Pin 7 X7 / Pin 8 TX+
TX-
RX+
VETH+
VETH+
RX-
VETH-
VETH-
Transmit Data +
Transmit Data -
Receive Data +
n.c. n.c. Receive Data -
n.c. n.c. Vorraussetzung fr den Einsatz des TCP/IP-Protokolls ist, dass jedes Gert am Netzwerk ber eine eigene IP-Adresse verfgt. Alle Reader verfgen ber eine werksseitig voreingestellte IP-Adresse. Tabelle 4-6: Standardkonfiguration der Ethernet-Schnittstelle Netzwerk IP-Adresse Subnet-Mask Port Adresse 192.168.10.10 255.255.255.0 10001 Hinweis:
Die Reader mssen nacheinander ans Netzwerk angeschlossen und konfiguriert werden. Jede IP-Adresse darf nur einmal im Netzwerk vertreten sein. Alternativ kann die Einstellung ber die asynchrone Schnittstelle erfolgen. FEIG ELECTRONIC GmbH Seite 17 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 4.3.4 USB-Schnittstelle (ID ISC.MRU200-USB) C S T U E D Der Anschluss der USB-Schnittstelle erfolgt ber Buchse X8. Die Belegung ist genormt. Die Daten-
rate des Readers ist auf 12 Mbit beschrnkt (USB Full Speed). Es kann ein Standard-USB-Kabel verwendet werden. Hinweis:
Die maximale Lnge des USB-Kabels darf 5 m betragen. Lngere Kabel sind nicht erlaubt. 4.4 Eingnge Die Optokopplereingnge an Klemmleiste X5 sind galvanisch von der Reader-Elektronik getrennt und mssen daher mit einer externen Gleichspannung versorgt werden. Die Eingangs-LEDs der Optokoppler sind intern mit einem Serienwiderstand Rint von 500 beschaltet. Tabelle 4-7: Pinbelegung Optokopplereingnge Klemme Kurzzeichen Beschreibung X5 / Pin 1 X5 / Pin 2 X5 / Pin 3 X5 / Pin 4 IN1+
IN1-
IN2+
IN2-
+ Eingang 1
- Eingang 1
+ Eingang 2
- Eingang 2 X5
Rext Rext Rint IN2 Rint IN1 Uext Uext Bild 4-7: Interne und mgliche externe Beschaltung der Optokopplereingnge Bei Versorgungsspannungen grer 10 V muss der Eingangsstrom durch einen weiteren externen Vorwiderstand (siehe Tabelle 4-8) auf max. 20 mA begrenzt werden. FEIG ELECTRONIC GmbH Seite 18 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 Tabelle 4-8: Externe Vorwiderstnde Externe Spannung Uext Bentigter externer Vorwiderstand Rext 5...10 V 11...15 V 16...20 V 21...24 V
270 560 820 Hinweise:
Die Eingnge sind fr eine maximale Eingangsspannung von 24 VDC und einen Ein-
gangsstrom von maximal 20 mA ausgelegt. Verpolung oder berlastung der Eingnge fhrt zu deren Zerstrung. Die Versorgungsspannung des Readers darf nicht zur Ansteuerung der Eingnge ver-
wendet werden, da es ansonsten durch zustzlich eingestrahlte Strungen zu Einbuen in der Lesereichweite kommen kann. H C S T U E D FEIG ELECTRONIC GmbH Seite 19 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 4.5 Ausgnge C S T U E D 4.5.1 Optokoppler Die Transistoranschlsse, Kollektor und Emitter, der beiden Optokopplerausgnge sind von der Reader-Elektronik galvanisch getrennt und ohne interne Zusatzbeschaltung an Klemme X4 nach auen gefhrt. Die Ausgnge mssen daher mit einer externen Spannung betrieben werden. Tabelle 4-9: Pinbelegung Optokopplerausgnge Klemme Kurzzeichen Beschreibung X4 / Pin 1 X4 / Pin 2 X4 / Pin 3 X4 / Pin 4 O1-C O1-E O2-C O2-E Kollektor Ausgang 1 Emitter Ausgang 1 Kollektor Ausgang 2 Emitter Ausgang 2 X4 E C E C OUT2 OUT1 Bild 4-8: Interne und mgliche externe Beschaltung der Optokopplerausgnge Hinweise:
Die Ausgnge sind fr max. 24 VDC Verpolung oder berlastung der Ausgnge fhrt zu deren Zerstrung. Die Ausgnge sind nur zum Schalten ohmscher Lasten vorgesehen.
/ 30 mA ausgelegt. FEIG ELECTRONIC GmbH Seite 20 von 54 M70201-2de-ID-B.doc H C S T U E D OBID i-scan 4.5.2 Relais Montage ID ISC.MRU200 Als Relaisausgang steht an X6 ein Wechsler zur Verfgung. Tabelle 4-10: Pinbelegung Relaisausgang Klemme Kurzzeichen Beschreibung X6 / Pin 1 X6 / Pin 2 X6 / Pin 3 COM NC NO Arbeitskontakt ffner Schlieer X6 N0 NC COM Uext Bild 4-9: Interne und mgliche externe Beschaltung des Relaisausgangs Hinweise:
Der Relaisausgang ist fr max. 24 VDC Der Relaisausgang ist nur zum Schalten ohmscher Lasten vorgesehen. Im Falle einer
/ 2 A ausgelegt. induktiven Last sind die Relaiskontakte durch eine externe Schutzbeschaltung zu scht-
zen. FEIG ELECTRONIC GmbH Seite 21 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 5 Bedien- und Anzeigeelemente C S T U E D 5.1 LEDs In Tabelle 5-1 sind die Konfigurationen der einzelnen LEDs aufgelistet:
Tabelle 5-1: Konfiguration der LEDs Kurzzeichen Beschreibung LED V1 (grn)
"RUN-LED 1"
- Signalisiert den ordnungsgemen Ablauf der internen Reader-Software Diagnose 1: RF-Kommunikation / EEPROM-Status
- Signalisiert durch ein kurzes Blinken die fehlerfreie Kommunikation mit einem Transponder auf der RF-Schnittstelle LED V2 (blau)
- Blinkt abwechselnd mit V1 nach dem Reset im Anschluss an ein Software-Update LED V3 (gelb) LED V4 (rot)
- Blinkt abwechselnd mit V1 falls nach einem Reset ein Datenfehler beim Lesen der Parameter auftrat Diagnose 2: Host-Kommunikation
- Signalisiert durch ein kurzes Blinken das Senden eines Protokolls an den Host Diagnose 3: RF-Warnung
- Leuchtet bei einem Fehler im RF-Teil des Readers. Der Fehlertyp kann per Software ber die Schnittstellen ausgelesen werden 5.2 T1: Reset-Taster Durch Bettigen des Tasters T1 wird am Reader ein Reset durchgefhrt. FEIG ELECTRONIC GmbH Seite 22 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 5.3 J1-J8: Schnittstellenkonfiguration ber die Jumper J7 J8 kann die asynchrone Schnittstelle als RS485- oder RS422-Schnittstelle konfiguriert werden. Tabelle 5-2: Konfiguration der RS485-/RS422-Schnitstelle Jumper J7 J8 RS485 geschlossen geschlossen RS422 offen offen Es knnen die eventuell bentigten Abschlusswiderstnde mit den Jumpern J1 bis J6 zugeschaltet werden. Tabelle 5-3: Abschlusswiderstnde der RS485/RS422 Jumper Geschlossen offen J1 J2 J5 J3 J4 J6 Pull-Up an RS4xx -B Pull-Down an RS4xx -A Abschlusswiderstand RS4xx -A RS4xx -B Pull-Up an RS422 -Z Pull-Down an RS422 -Y Abschlusswiderstand RS422 -Y RS422 -Z ohne Pull-Up an RS4xx -B ohne Pull-Down an RS4xx -A ohne Abschlusswiderstand RS485 -A RS485 -B ohne Pull-Up an RS422 -Z ohne Pull-Down an RS422 -Y ohne Abschlusswiderstand RS422 -Y RS422 -Z 500 Ohm J1 J8 J7 500 Ohm 120 Ohm J5 J2 RS485 +
RS485 -
J3 500 J1 500 J6 120 J5 J4 500 120 J2 500 RS422 Z+
RS422 Y-
RS422 B+
RS422 A-
Bild 5-1: Jumper der RS485-Schnittstelle Bild 5-2: Jumper der RS422-Schnittstelle FEIG ELECTRONIC GmbH Seite 23 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 5.4 X62: Bootloader Modus C S T U E D Tabelle 5-4: Stiftleiste X62 Die Stiftleiste X62 kann mit einem Jumper (Rasterma 2,0 mm) kurzgeschlossen werden. In Tabelle 5-4 ist die Funktion der Stiftleiste X62 beschrieben. X60 offen kurzgeschlossen Beschreibung keine Auswirkung nach Bettigen des Tasters T1 wird der Reader in den Bootloader Mo-
dus versetzt. FEIG ELECTRONIC GmbH Seite 24 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 6 Technische Daten Mechanische Daten Gehuse Abmessungen (B x H x T) Gewicht Schutzart Farbe Elektrische Daten Spannungsversorgung Leistungsaufnahme Betriebsfrequenz Sendeleistung Modulationsgrad Empfnger Antennenanschlsse
- 2 x gemultiplext Ausgnge:
- 2 Optokoppler
- 1 Relais (1 x Wechsler) Eingnge
- 1 Optokoppler Schnittstellen Aluminium Druckguss, pulverbeschichtet, verschliebarer Klappdeckel 200 x 110 x 60 mm 1,1 kg IP 54 RAL 7040 (hnlich Fenstergrau) 5 %
12...24 VDC Noise Ripple : max. 150 mV max. 15 VA 865,6...867,6 MHz (EN 302 208) 902...928 MHz (FCC CFR 47 Part 15.247) 100...300 mW (100 mW Step Software) 20...40% und 100%
(per Software einstellbar) Datenraten 40 kbps, 64 kbps, 80 kbps 2 x SMA Buchse (50 ) 24 VDC 24 VDC
/ 30 mA (galvanisch getrennt)
/ 2 A max. 24 VDC
/ 20 mA
- RS232
- RS485 / RS422 (wahlweise einstellbar)
- Ethernet (TCP/IP) (ID ISC.MRU200-E)
- USB (ID ISC.MRU200-A) FEIG ELECTRONIC GmbH Seite 25 von 54 M70201-2de-ID-B.doc H C S T U E D OBID i-scan Montage ID ISC.MRU200 Protokoll Modi Untersttzte Transponder Signalgeber optisch Multi-Reader-Betrieb
- FEIG ISO Host
- Buffer Reader Mode
(Data Filtering and buffering)
- Scan Mode
- EPC class 1 Gen 2
- 18000-6-B 4 LEDs zur Diagnose des Betriebszustandes
(UpgradeCode notwendig) Synchronisation der Luftprotokolle durch Ver-
wendung der Reader Synchronisation Umgebungsbedingungen Temperaturbereich
- Betrieb
- Lagerung Vibration Schock Angewendete Normen Zulassung Funk
- Europa
- USA EMV Sicherheit Niederspannung
- Human Exposure
-25...+55C
-25...+85C EN60068-2-6 10...150 Hz :
EN60068-2-27 Beschleunigung : 30 g 0,075 mm / 1 g EN 302 208 FCC 47 CFR Part 15 EN 301 489 EN 60950 UL 60950-1 EN 50364 FEIG ELECTRONIC GmbH Seite 26 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H C S T U E D 6.1 Zulassung 6.1.1 Europa (CE) Die Funkanlage entspricht, bei bestimmungsgemer Verwendung den grundlegenden Anforde-
rungen des Artikels 3 und den brigen einschlgigen Bestimmungen der R&TTE Richtlinie 1999/5/EG vom Mrz 99. Equipment Classification gem ETSI EN 302 208 und ETSI EN 301 489: Class 2 6.1.2 USA (FCC) FCC ID: PJMMRU200 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. NOTICE:
Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. FEIG ELECTRONIC GmbH Seite 27 von 54 M70201-2de-ID-B.doc OBID i-scan Montage ID ISC.MRU200 H 6.1.3 USA und Kanada (UL) C S T U E D FEIG ELECTRONIC GmbH Seite 28 von 54 M70201-2de-ID-B.doc H S I L G N E OBID i-scan Installation Note ID ISC.MRU200 Copyright 2007/2008 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others. OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH. FEIG ELECTRONIC GmbH Page 30 of 54 M70201-2de-ID-B.doc OBID i-scan Installation Contents 1 2 Safety Instructions / Warning - Read before start-up !
Features of the Reader Family ID ISC.MRU200 ID ISC.MRU200 33 34 H S I L G N E 2.1 2.2 Available Reader Types ............................................................................................34 Scope of delivery ......................................................................................................34 3 Installation 35 3.1 3.2 3.3 3.4 Cable Glands .............................................................................................................36 Seal Caps...................................................................................................................36 Cover stays................................................................................................................37 Decorative Covers.....................................................................................................37 4 Terminals and Jacks 38 4.1 4.2 Supply Voltage ..........................................................................................................39 Antenna Connections ...............................................................................................40 4.3 Interfaces...................................................................................................................41 4.3.1 RS232 Interface ..........................................................................................................41 4.3.2 RS485 / RS422 Interface (ID ISC.MRU200-USB) .......................................................42 4.3.3 Ethernet Interface (ID ISC.MRU200-E) .......................................................................43 4.3.4 USB Interface (ID ISC.MRU200-USB).........................................................................44 4.4 Inputs.........................................................................................................................44 4.5 Outputs ......................................................................................................................46 4.5.1 Optocouplers...............................................................................................................46 4.5.2 Relay...........................................................................................................................47 5 Operating and Display Elements 48 5.1 5.2 LEDs...........................................................................................................................48 Reset Button..............................................................................................................48 FEIG ELECTRONIC GmbH Page 31 of 54 M70201-2de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 5.3 5.4 J1-J8: Interface configuration ..................................................................................49 X62: Boot Loader Mode ............................................................................................50 6 Technical Data 51 6.1 Approval ....................................................................................................................53 6.1.1 Europe (CE)................................................................................................................53 6.1.2 USA (FCC)..................................................................................................................53 6.1.3 USA and Canada (UL) ................................................................................................54 FEIG ELECTRONIC GmbH Page 32 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 H S I L G N E 1 Safety Instructions / Warning - Read before start-up !
The device may only be used for the intended purpose designed by for the manufacturer. When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation of 20 cm (8 inch) between antenna and the human body must be maintained. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer. The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device. Repairs may only be executed by the manufacturer. Installation, operation, and maintenance procedures should only be carried out by qualified personnel. Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . When working on devices the valid safety regulations must be observed. Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm (10 inch) between the device and your cardiac pace-
maker and not stay in the immediate proximity of the devices antenna for any length of time. FEIG ELECTRONIC GmbH Page 33 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 2 Features of the Reader Family ID ISC.MRU200 The Reader has been developed for reading passive data carriers, so-called Smart Labels, using an operating frequency in the UHF range. 2.1 Available Reader Types H S I L G N E The following Readers are currently available:
Table 2-1: Available Reader types Reader type ID ISC.MRU200-USB-EU ID ISC.MRU200-E-EU ID ISC.MRU200-USB-FCC ID ISC.MRU200-E-FCC Description Reader with USB Interface for Europe Reader with Ethernet Interface for Europe Reader with USB Interface for USA Reader with Ethernet-Interface for USA 2.2 Scope of delivery The following components are included in the scope of delivery:
1 x Reader ID ISC.MRU200 8 x jumper 2 x seal cap M16 1 x seal cap M12 1 x seal cap - reducer 2 x decorative cover, clip-on 2 x integrated cover stays FEIG ELECTRONIC GmbH Page 34 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 3 Installation The Reader is designed for wall mount. Four Holes are provided in the housing for wall attachment
(d=7mm (.27), measurement 60x182mm). The housing does not need to be opened for installa-
tion on a wall (see Fig. 3-1). The size and type of the screw anchors depends considerably on the strength of the wall. The anchors should be capable of withstanding a permissible load of at least 1.5 kN per anchor for all load directions (Undersurface steal e.g. cylinder head screw M5 steal zinc coated DIN 84 / ISO 1207, property class 8.8 or concrete, stone e.g. plastic anchor 6mm with wood screw DIN96 d=4mm). The maximum size of the screw head is 8.5mm (0.33) H S I L G N E 200 (7.87) 182 (7.16) 6
) 6 3
. 2
0 6
) 3 3
. 4
0 1 1 1 2 3 4 5 Fig. 3-1: Housing ID ISC.MRU200 (all dimensions in mm (inch)) FEIG ELECTRONIC GmbH Page 35 of 54 M70201-2de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 3.1 Cable Glands The different cable glands are shown in Table 3-1. Table 3-1: ID ISC.MRU200 cable glands Cable gland 1 2 3 4 5 6 Size M 16 M 16 M 16 M 12 M 12 M 25 Clamping Range in mm (inch) 4,5...10 (0.18...0.39) 4,5...10 (0.18...0.39) 4,5...10 (0.18...0.39) 3,5...7 (0.14...0.28) 3,5...7 (0.14...0.28) 9...17 (0.35...0.67) 3.2 Seal Caps Description Antenna Cable 1 Antenna Cable 2 Inputs / Relay / Outputs Interface (serial) Supply voltage Ethernet Interface (Model E only) USB Interface (Model USB only) The seal caps included in the scope of delivery can be used to close off unused cable fittings. This is necessary for reaching the IP54 class. The reducing ring provided is intended for the network connection. The slotted reducer is placed over the network cable and then fixed in place in the cable gland. Fig. 3-2: network connection with slotted reducer FEIG ELECTRONIC GmbH Page 36 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 3.3 Cover stays The two cover stays can be used to attach the cover to the housing. The cover stays are inserted into the openings provided for this purpose. H S I L G N E Fig. 3-3: Cover stay 3.4 Decorative Covers The decorative covers are attached after installing the Reader. The slot on the long side of the cover is used for disassembling the cover. Use a screwdriver to remove the cover. Fig. 3-4: Decorative cover FEIG ELECTRONIC GmbH Page 37 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 4 Terminals and Jacks Fig. 4-1 and Fig. 4-2 show terminals, jacks and operating elements of reader type -USB respec-
tively reader type -E. H S I X1 VDCGND X8 L G N E D N G D x R D x T X2 D N G
A
B
Y
Z X3 1 J 8 J C 1 T U O E C 2 T U O E X4
1 N I
2 N I
X5 M O C C N 0 N X6 1 K 1 T 2 6 X 2 T N A 1 T N A 1 V 2 V 3 V 4 V Fig. 4-1: Terminals, jacks and operating elements of Type -USB FEIG ELECTRONIC GmbH Page 38 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 D N G X1 VDCGND X7 Fig. 4-2: Terminals, jacks and operating elements of Type -E 4.1 Supply Voltage Connect the 12...24 VDC supply and the Reader module must not exceed 3m (118 inch). Table 4-1: Supply voltage pin assignments supply voltage to Terminal X1. The cable length between the power Terminal Abbreviation Description X1 / Pin 1 X1 / Pin 2 VDC GND Vcc supply voltage (+) Ground supply voltage (-) GND VDC X1 H S I L G N E Fig. 4-3: Connecting the supply voltage The output power of the power supply should be at least 15 W. At all installation according to UL 60950 or EN 60950, by use of flexible cords, the NEC rules according article 400.7 (8) and 400.8 (1)-(7) must be this unit has to be supplied by a Listed NEC Class 2/LPS supply, only. applied. Note:
Reversing the polarity of the supply voltage may destroy the unit. FEIG ELECTRONIC GmbH Page 39 of 54 M70201-2de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 4.2 Antenna Connections The external antennas are connected to the SMA jacks ANT1 and ANT2. The SWR of the con-
nected antennas with the cables should not be worse than 1.5:1. Table 4-2: Antenna Connections ANT1 and ANT2 Connections ANT1, ANT2 Description SMA jacks for antenna connections
(input impedance 50 ) ANT1 ANT2 Fig. 4-4: Antenna Connections ANT1 and ANT2 Note:
The maximum tightening torque of the SMA sockets is 0,45 Nm (4.0 lbf in). FEIG ELECTRONIC GmbH Page 40 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 4.3 Interfaces 4.3.1 RS232 Interface The RS232 interface is connected on X2. The transmission parameters can be configured by means of software protocol. H S I L G N E Table 4-3: RS232 interface pinouts Terminal Abbreviation Description X2 / Pin 1 X2 / Pin 2 X2 / Pin 3 GND RxD TxD RS232 GND RS232 RxD RS232 TxD Reader X2 / Pin 1 (GND) X2 / Pin 2 (RxD) X2 / Pin 3 (TxD) PC Pin 5 Pin 3 Pin 2 2 TxD RxD GND X 9-pol. DUB-D-Buchse PC Fig. 4-5: Wiring example for connecting the RS232 interface FEIG ELECTRONIC GmbH Page 41 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 4.3.2 RS485 / RS422 Interface (ID ISC.MRU200-USB) The second asynchronous interface can be configured for RS485 or RS422 (see 5.3 J1-J8: Inter-
face configuration). The RS485 interface respectively RS422 interface is connected to X3. Table 4-4: RS485 / RS422 interface pinouts Terminal Abbreviation Description H S I L G N E X3 / Pin 1 X3 / Pin 2 X3 / Pin 3 X3 / Pin 4 X3 / Pin 5 GND A-
B+
Y-
Z+
RS485 / RS422 GND RS485 / RS422 (A -) RS485 / RS422 (B +) RS422 (Y -) RS422 (Z +) Z+ Y-
B+ A- GND 3 X Fig. 4-6: Wiring the RSR485 / RS422 interface FEIG ELECTRONIC GmbH Page 42 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 4.3.3 Ethernet Interface (ID ISC.MRU200-E) The Reader has an integrated 10 / 100 base-T network port for an RJ45. Connection is made on X7. With structured cabling Cat 5 cables should be used. This ensures reliable operation at 10 Mbps or 100 Mbps. Table 4-5: Ethernet interface pinouts Terminal Abbreviation Description X7 / Pin 1 X7 / Pin 2 X7 / Pin 3 X7 / Pin 4 X7 / Pin 5 X7 / Pin 6 X7 / Pin 7 X7 / Pin 8 TX+
TX-
RX+
VETH+
VETH+
RX-
VETH-
VETH-
Transmit Data +
Transmit Data -
Receive Data +
n.c. n.c. Receive Data -
n.c. n.c. H S I L G N E The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address.. Table 4-6: Standard configuration of the Ethernet connection Network IP-Address Subnet-Mask Port Address 192.168.10.10 255.255.255.0 10001 Note:
The readers must be connected to the network and configured one after the other. Every IP-
Address must be used only one time. Alternatively this configuration can be done with the asynchronous interface. FEIG ELECTRONIC GmbH Page 43 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 4.3.4 USB Interface (ID ISC.MRU200-USB) The USB socket on the board is terminal X8. The pinout is standardized. The data rate is reduced to 12 Mbit (USB full speed). A standard USB-cable can be used. Note:
The length of the USB-cable can be a max. of 5m (20 inch). It is not allowed to use longer cables. H S I L G N E 4.4 Inputs The optocoupler inputs in Terminal X5 are galvanically isolated from the Reader electronics and must therefore be externally supplied. The input LEDs for the optocouplers are switch internally with a series resistor Rint of 500 . Table 4-7: Optocoupler input pin assignments Terminal Abbreviation Description X5 / Pin 1 X5 / Pin 2 X5 / Pin 3 X5 / Pin 4 IN1+
IN1-
IN2+
IN2-
+ Input 1
- Input 1
+ Input 2
- Input 2 X5
Rext Rext Rint IN2 Rint IN1 Uext Uext Fig. 4-7: Internal and possible external wiring of the optocoupler inputs For supply voltages of greater than 10 V the input current must be limited to max. 20 mA by an additional external series resistor (see Table 4-8). FEIG ELECTRONIC GmbH Page 44 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 Table 4-8: External Series Resistor External voltage Uext Required external series resistor Rext 5...10 V 11...15 V 16...20 V 21...24 V
270 560 820 H S I Notes:
The inputs are configured for a maximum input current of 24 VDC and an input current of maximum 20 mA. Reversing the polarity or overloading the inputs will destroy them. The Reader supply voltage must not be used to drive the inputs, since otherwise additionally induced noise may reduce the effective reading range. L G N E FEIG ELECTRONIC GmbH Page 45 of 54 M70201-2de-ID-B.doc Installation ID ISC.MRU200 OBID i-scan 4.5 Outputs 4.5.1 Optocouplers The transistor connections of the two optocoupler outputs, collector and emitter, are galvanically isolated from the Reader electronics and brought out with no internal circuitry to terminal X4. The outputs must therefore be powered with an external power supply. H S I L G N E Table 4-9: Optocoupler output pin configuration Terminal Abbreviation Description X4 / Pin 1 X4 / Pin 2 X4 / Pin 3 X4 / Pin 4 O1-C O1-E O2-C O2-E Collector Output 1 Emitter Output 1 Collector Output 2 Emitter Output 2 X4 E C E C OUT2 OUT1 Fig. 4-8: Internal and possible external wiring of the optocoupler outputs Notes:
The outputs are configured for max. 24 VDC Reversing the polarity or overloading the outputs will destroy them. The outputs are intended for switching resistive loads only.
/ 30 mA. FEIG ELECTRONIC GmbH Page 46 of 54 M70201-2de-ID-B.doc OBID i-scan 4.5.2 Relay Installation ID ISC.MRU200 H S I L G N E A changeover relay is provided on terminal X6. Table 4-10: Relay output pinouts Terminal Abbreviation Description X6 / Pin 1 X6 / Pin 2 X6 / Pin 3 COM NC NO Working contact Normally closed Normally open X6 N0 NC COM Uext Fig. 4-9: Internal and possible external wiring of the relay output Notes:
The relay outputs are configured for max. 24 VDC The relay outputs are intended for switching resistive loads only. If an inductive load is used, the relay contacts must be protected by means of an external protection circuit.
/ 2 A. FEIG ELECTRONIC GmbH Page 47 of 54 M70201-2de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 5 Operating and Display Elements 5.1 LEDs Table 5-1 shows the LED configuration. Table 5-1: LED configuration Abbreviation LED V1 (green) LED V2 (blue) LED V3 (yellow) LED V4 (red) Description Indicates proper running of the internal Reader software
"RUN-LED 1"
Diagnostic 1: RF communication / EEPROM status
- Short flashing indicates errorless communication with a transponder on the RF interface
- Flashes alternately with V1 after a reset following a software update
- Flashes alternately with V1 in case of a data error when reading the parameters after a reset Diagnostic 2: Host communication
- Short flashing indicates sending of a protocol to the host Diagnostic 4: RF warning
- Comes on when there is an error in the RF section of the Reader. The error type can be read out via software over the RS232/RS485 interface 5.2 Reset Button Pressing the button T1 resets the reader. FEIG ELECTRONIC GmbH Page 48 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 5.3 J1-J8: Interface configuration Jumpers J7 and J8 are used to configure the asynchronous interface as an RS485 or R422 port. H S I L G N E Table 5-2: Configuration of the RS485 / RS422 port Jumper J7 J8 RS485 closed closed RS422 open open Any termination resistors needed can be enabled using jumpers J1 through J6. Table 5-3: Termination resistors for RS485 / RS422 Jumper closed open J1 J2 J5 J3 J4 J6 Pull-Up on RS4xx - B Pull-Down on RS4xx - A Termination resistor RS4xx - A RS4xx - B Pull-Up on RS422 - Z Pull-Down on RS422 - Y Termination resistor RS422 - Y RS422 - Z without Pull-Up on RS4xx - B without Pull-Down on RS4xx A without Termination resistor RS485 - A RS485 - B without Pull-Up on RS422 - Z without Pull-Down on RS422 Y without Termination resistor RS422 - Y RS422 - Z 500 Ohm J1 J8 J7 500 Ohm 120 Ohm J5 J2 RS485 +
RS485 -
J3 500 J1 500 J6 120 J5 J4 500 120 J2 500 RS422 Z+
RS422 Y-
RS422 B+
RS422 A-
Fig. 5-1: RS485 Interface Jumper Fig. 5-2: RS422 Interface Jumper FEIG ELECTRONIC GmbH Page 49 of 54 M70201-2de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 5.4 X62: Boot Loader Mode The pin connector X62 can be closed with a jumper (2.0 mm). Table 5-4: pin connector X62 X62 open closed Description no effect after pressing the button T1 the reader is in th boot loader mode FEIG ELECTRONIC GmbH Page 50 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 H S I L G N E 6 Technical Data Mechanical Data Housing Dimensions ( W x H x D ) Weight Die-case aluminum, powder coated, lockable hinged cover 200 x 110 x 60 mm
(7.9 inch x 4.3 inch x 2.4 inch) approx. 1,1 kg (2.4 lb) Enclosure rating IP 54 Color RAL 7040 (similar to window gray) Electrical Data Supply Voltage Power Consumption Operating Frequency Transmitting Power Modulation Receiver Antenna Connection
- 2 x multiplexing Outputs:
- 2 Optocouplers
- 1 Relay (1 x Changeover) Inputs
- 2 Optocouplers 5 %
12...24 VDC Noise Ripple : max. 150 mV max. 15 VA 869.525 MHz (EN 300 220) 865.6...867.6 MHz (EN 302 208) 902...928 MHz (FCC CFR 47 Part 15.247) 100...300 mW (100 mW Step Software) 20...40% and 100%
(software configurable) Data rates 40 kbps, 64 kbps, 80 kbps 2 x SMA socket (50 ) 24 VDC 24 VDC
/ 30 mA (galvanically isolated)
/ 2 A max. 24 VDC
/ 20 mA (galvanically isolated) FEIG ELECTRONIC GmbH Page 51 of 54 M70201-2de-ID-B.doc H S I L G N E OBID i-scan Installation ID ISC.MRU200 Interfaces Protocol modes Supported Transponders Optical Indicators Multi-Reader Operation
- RS232
- RS485 / RS422 (selectable)
- Ethernet (TCP/IP) (ID ISC.MRU200-E only)
- USB (ID ISC.MRU200-USB only)
- FEIG ISO Host
- Buffer Reader Mode
(Data Filtering and buffering)
- Scan Mode
- EPC class 1 Gen 2
- 18000-6-B 4 LEDs for operating status diagnostics
(UpgradeCode required) Synchronization of the air protocols using Reader synchronization Ambient Temperature range
- Operating
- Storage Vibration Shock Applicable Standards RF approval
- Europe
- USA EMC Safety
- Low-Voltage
- Human Exposure
-25...+55C (-13...+131F)
-25...+85C (-13...+185F) EN60068-2-6 10...150 Hz :
EN60068-2-27 Acceleration 0.075 mm / 1 g
: 30 g EN 302 208 / EN 300 220 FCC 47 CFR Part 15 EN 301 489 EN 60950 UL 60950-1 EN 50364 FEIG ELECTRONIC GmbH Page 52 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 6.1 Approval 6.1.1 Europe (CE) When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99. H S I L G N E Equipment Classification according to ETSI EN 302 208 and ETSI EN 301 489: Class 2 6.1.2 USA (FCC) FCC ID: PJMMRU200 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. NOTICE:
Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. FEIG ELECTRONIC GmbH Page 53 of 54 M70201-2de-ID-B.doc OBID i-scan Installation ID ISC.MRU200 6.1.3 USA and Canada (UL) H S I L G N E FEIG ELECTRONIC GmbH Page 54 of 54 M70201-2de-ID-B.doc
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2009-08-20 | 902.75 ~ 927.25 | DSS - Part 15 Spread Spectrum Transmitter | Class II permissive change or modification of presently authorized equipment |
2 | 2007-12-21 | 902.75 ~ 927.25 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2009-08-20
|
||||
1 2 |
2007-12-21
|
|||||
1 2 | Applicant's complete, legal business name |
Feig Electronic GmbH
|
||||
1 2 | FCC Registration Number (FRN) |
0007634793
|
||||
1 2 | Physical Address |
Lange Strae 4
|
||||
1 2 |
Weilburg-Waldhausen, N/A D-35781
|
|||||
1 2 |
Germany
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
D******@Phoenix-Testlab.de
|
||||
1 2 |
G******@ict.cetecom.de
|
|||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
PJM
|
||||
1 2 | Equipment Product Code |
MRU200
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
E****** R********
|
||||
1 2 | Title |
Manager
|
||||
1 2 | Telephone Number |
+49 6********
|
||||
1 2 | Fax Number |
+49 6********
|
||||
1 2 |
e******@feig.de
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | UHF Reader | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Class II permissive change or modification of presently authorized equipment | ||||
1 2 | Original Equipment | |||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Output Power listed is conducted. Professional Installation only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Endusers and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Class II Change Filing adds additional antennas (same type but higher antenna gain as originally filed) and housing type. | ||||
1 2 | Professional Installation only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Installers must be provided with antenna installation instructions. Installers and End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. | |||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
TUV SUD Product Service GmbH PS-EMC-STR
|
||||
1 2 |
CTC advanced GmbH (former CETECOM ICT Services )
|
|||||
1 2 | Name |
R******** H******
|
||||
1 2 |
G****** S****
|
|||||
1 2 | Telephone Number |
49-09********
|
||||
1 2 |
49-68********
|
|||||
1 2 | Fax Number |
49-09********
|
||||
1 2 |
49-68********
|
|||||
1 2 |
r******@tuev-sued.de
|
|||||
1 2 |
t******@ctcadvanced.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 902.75000000 | 927.25000000 | 0.2810000 | ||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | 902.75000000 | 927.25000000 | 0.3540000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC