all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 1.75 MiB | July 07 2011 / March 01 2012 | |||
1 | Cover Letter(s) | July 07 2011 | ||||||
1 | Cover Letter(s) | July 07 2011 | ||||||
1 | Cover Letter(s) | July 07 2011 | ||||||
1 | External Photos | July 07 2011 / March 01 2012 | ||||||
1 | Internal Photos | July 07 2011 / March 01 2012 | ||||||
1 | ID Label/Location Info | July 07 2011 | ||||||
1 | RF Exposure Info | July 07 2011 | ||||||
1 | Test Report | July 07 2011 | ||||||
1 | Test Setup Photos | July 07 2011 / March 01 2012 |
1 | Users Manual | Users Manual | 1.75 MiB | July 07 2011 / March 01 2012 |
Zigbee USB Serial Adapter ABOUT FZ200BS Zigbee 2006 Support USB Interface 4dBi Dipole Antenna Provided AT Command provided FZ200BS Manual VERSION 0.1.0
(C) Copyright FIRMTECH Co., Ltd. 2005 All rights reserved The products and operation descriptions contained herein shall be protected by copyright law. Any part or whole of products or operation description shall not be copied, reproduced, translated, nor transformed into readable form by electronic device or machines, without prior consent in writing by FIRMTECH Co., Ltd. There might be some misprinting or technical faults in the products and operation description which are subject to change without prior notice. FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is con-nected. Consult the dealer or an experienced radio/TV technician for help. Caution Modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation IMPORTANT NOTE:
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2 FZ200BS Manual VERSION 0.1.0 FIRMTECH Co., Ltd. 2005 Room B-606, Ssangyong IT Twin Tower, Sangdaewon-dong, 442-5, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea 462-120 Homepage : www.firmtech.co.kr Marketing Inquiry : contact@firmtech.co.kr Technical Support Inquiry : techsupport@firmtech.co.kr Tel : 82-31-719-4812 Fax : 82-31-719-4834 3 FZ200BS Manual VERSION 0.1.0 What is zigbee?
1. Features of Bluetooth 1) Objectives of Zigbee : To realize Personal Wireless Communication for short distance and slow speed with Low Power consumption and Low Cost, which is based on IEEE 802.15.4 Standard. 2) Frequency in Use : To use ISM(Industrial, Scientific, Medical) Band which does not require any permission to use.
- 2.405 ~ 2.480 GHz: 16 channels in all nations (No.11 ~26 channel) 3) Transmission Rate
- 2.405 ~ 2.480 GHz: 250Kbps 4) Working distance
- Inside: 30m, Outside: 100m 5) Configuration
- Zigbee device is configured of Coordinator, Router and End Device.
- Coordinator configures Network
- Router expands Network
- End device participates in Network
- With 64bit address, can configure a maximum of 65536 Networks connected 6) Reliability
- Supports Network level and Device level using Authentication-Network Key and Link Key.
- Supports encrypted packet transmission using 128bit AES Encryption.
- Guarantees data reliability on the application layer using ACK option in APS Packet
- Guarantees data reliability on the physical layer using ACK option in MAC Packet. 4 FZ200BS Manual VERSION 0.1.0 2. Zigbee operation
< Zigbee Mesh network configuration>
1) Coordinator configures the Zigbee Network. Coordinator communicates with Router and End Device. 2) Router expands Network by connecting Coordinator or other Routers. 3) End Device participates in Zigbee network and communicates with Router or Coordinator. 5 FZ200BS Manual VERSION 0.1.0 Products overview FZ200BS can configure Zigbee network with low power consumption and low capacity by using Zigbee stack. Serial data transmission via USB interface is available FZ200BS can be used in conjunction with the FZ100BS/FZ750BS/FZ750BC.
< Major features of FZ200BS>
1. Zigbee 2006 support 2. Mesh network support 3. USB Interface is configured as easy as installing a USB driver for the serial data input / output available 4. Supports AT command, and control Devices by using the AT command. 5. Can check whether data is successfully transmitted or not by using ACK option. 6. By using Key Option, can obtain new Zigbee Network Routes so that data re-transmission is possible even if finding the communication route is failed for the first time. 7. Use 2.400 ~ 2.4835 GHz(ISM Band) 15 channels (No.11 ~25 channel) 11 (0x0B): 2405MHZ, 12 (0x0C): 2410MHZ, 13 (0x0D): 2415MHZ, 14 (0x0E): 2420MHZ, 15 (0x0F): 2425MHZ, 16 (0x10): 2430MHZ, 17 (0x11): 2435MHZ, 18 (0x12): 2440MHZ, 19 (0x13): 2445MHZ, 20 (0x14): 2450MHZ, 21 (0x15): 2455MHZ, 22 (0x16): 2460MHZ, 23 (0x17): 2465MHZ, 24 (0x18): 2470MHZ, 25 (0x19): 2475MHZ, 26 (0x20): 2480MHZ We request the new users of FZ200BS to read the information on this description carefully before they start to use the products. Please consult Firmtech.co., Ltd if you want to configure Zigbee Network using more than 30 devices of FZ200BS 6 FZ200BS Manual VERSION 0.1.0 FZ200BS Overview
(1) To configure the Zigbee network, set each device (FZ200BS) to Coordinator, Router and End Device. The initial factory set value of FZ200BS is set to Router.
(2) Do not use Broadcast accompanied by a lot of traffic in the Zigbee network unless it is vital to be used. It is not recommended to make a lot of traffic in the Zigbee network because it causes lots of trouble when transmitting data and bothers to set the new route toward target devices.
(3) Do not set short time for data transmission in the Zigbee Network. The more nodes the Zigbee Network has, the longer time for transmission time should be set. Example.1) Zigbee Network Contribution using 10 FZ200BSs, Set a time space to 2seconds for data transmission between FZ200BSs.
(set 2sec minimally per 10 FZ200BSs) Example.2) Zigbee Network Contribution using 20 FZ200BSs, Set a time space to 4seconds for data transmission between FZ200BSs.
(set 2sec minimally per 10 FZ200BSs*2=4sec) It is not recommended to make a lot of traffic in the Zigbee Network. It is not recommended to make a lot of traffic in the Zigbee network because it causes lots of trouble when transmitting data and bothers to set the new route toward target devices. 7 FZ200BS Manual VERSION 0.1.0
(4) Coordinator and Router can configure child nodes up to 8
(5) End Devices cannot configure Child nodes Setting FZ200BS to End Devices should be prior to the Zigbee Network Configuration. If you want to change the device type of FZ200BS from Router to End Device in the Zigbee Network, you had better re-configure the whole Zigbee Network in advance. FZ200BS can configure Child nodes after they are set to Routers and participated in the Zigbee Network. Also, other devices can participate in the Zigbee Network by setting the FZ200BS set to Routers to their parent nodes, as well. If you change the FZ200BS set to parent nodes to End Devices, the current End Devices cannot configure child nodes. In this situation, it is possibly can happen that other devices set the Routers to their parent nodes before the Routers are changed to End devices. FZ200BS supports mesh network, so you can expect the stable Zigbee Network. However, in order to make sure of proper Zigbee Network configuration, FZ200BS of child nodes had better save FZ200BSs set to Router (or coordinator) as their parent nodes. Thus, you had better set the type of each Device (especially End Device) before the Zigbee Network Configuration. 8 FZ200BS Manual VERSION 0.1.0
(6) FZ200BS can configure the Zigbee Network up to 4 Depth.
(7) FZ200BSC configures the Zigbee Network with one Coordinator.
(8) FZ200BS can transmit data by multipath because it supports mesh network. Contribute the Zigbee Network which has multipath.
(9) If you input Serial data into FZ200BS, It transmits the Serial data to its target device.
(10) FZ200BS has STATUS LED for showing the status of the Device.
(OK Status LED, ERROR Status LED, Condition Status LED)
(11) When you transmit data by using FZ200BS, you need to check the result value for the transmission 9 FZ200BS Manual VERSION 0.1.0 through the OK/ERROR LED.
(12) FZ200BS has an IEEE ADDRESS and a NETWORK ADDRESS. 64 Bit IEEE ADDRESS is a physical address of FZ200BS. Every device has its own IEEE ADDRESS and the IEEE ADDRESS is not changeable. FZ200BS set target devices by using IEEE ADDRESS. In conclusion, target device set-up is an inquiry using IEEE ADDRESS for NETWORK ADDRESS of its target devices FZ200BS has a 16 Bit of NETWORK ADDRESS for the Zigbee Network communication. NETWORK ADDRESS is given when FZ200BS participates in the Zigbee Network. NETWORK ADDRESS can be changed depending on the Zigbee Network Configuration. NETWORK ADDRESS cannot be shown unless FZ200BS participates in the Zigbee Network. FZ200BS performs data transmission by using NETWORK ADDRESS.
(13) If you configure the Zigbee Network and perform data transmission, the result value is shown as
[volume of received data > volume of transmitted data]. FZ200BS on a MAC layer automatically re-transmits data depending on the Zigbee Network Configuration. In case of using ACK option, FZ200BS on an application layer automatically re-transmits data depending on the Zigbee Network Configuration. Thus, Received data could be more than 2 depending on the Zigbee network configuration even if only one data is transmitted. 10 FZ200BS Manual VERSION 0.1.0
< Routing table update of FZ200BS >
Routing table is assigned to each FZ200BS after the Zigbee Network Configuration. Below is the Zigbee network status when data is transmitted from Router2 to Router1 to Coordinator. Data is input into Router2, the Router2 transmits the data to Router1, and then the Router1 transmits the data to Coordinator. Consequently, the data inputted into Router2 is transmitted to Coordinator by routing table belonging to Router2 and Router1 If Router 1 is in abnormal status in the Zigbee Network, Router2 cannot transmit data, and shows its error status through ERROR port. When ACK Option is disabled (NACK communication) of FZ200BS, Device is automatically reset and Router2 creates a new routing table if the Router2 happens to show its error status 5times successively through the error port because of the abnormal Router1. Multipath set-up is required ahead of the time to update the routing table. When the ACK Option of FZ200BS is enabled (ACK communication), users should control the routing table directly to update it. If the data transmission is successively failed, users need to reset its target devices address (same as the existing one) and the Device. 11 FZ200BS Manual VERSION 0.1.0 List of contents IMPORTANT NOTE: .......................................................................................................................................................2 FCC RF RADIATION EXPOSURE STATEMENT:......................................................................................................2 1. PRODUCT COMPONENTS......................................................................................................................................13 2. PRODUCT APPEARANCE........................................................................................................................................14 3. USB INTERFACE.......................................................................................................................................................14 4. DIP SWITCH & INTERFACE SOCKET ...................................................................................................................15 5. LED INDICATION / RESET SWITCH......................................................................................................................16 6. PRODUCT PERFORMANCE....................................................................................................................................17 7. CURRENT CONSUMPTION .....................................................................................................................................17 8. SET VALUE OF PRODUCT......................................................................................................................................17 9. USES GUIDE..............................................................................................................................................................18 9-1. SERIAL COMMUNICATION (HYPER TERMINAL) PROGRAM EXECUTE...................................................................... 19 9-2. SET-UP FZ200BS DEVICE TYPE ........................................................................................................................ 21 9-2-1. FZ200BS End Device Set-up.............................................................................................................. 22 9-2-2. FZ200BS Router Set-up....................................................................................................................... 23 9-2-3. FZ200BS Coordinator set-up.............................................................................................................. 24 9-3. THE ZIGBEE NETWORK CONFIGURATION.............................................................................................................. 25 9-3-1. The Zigbee Network configuration..................................................................................................... 25 9-3-2. Zigbee Network Extension ................................................................................................................... 25 9-3-3. Zigbee Network Participation .............................................................................................................. 26 9-4. TARGET DEVICE SET-UP....................................................................................................................................... 26 9-4-1. Searching for an IEEE ADDRESS of Coordinator........................................................................... 27 9-4-2. Target device set-up ............................................................................................................................ 27 9-5. SERIAL DATA TRANSMISSION................................................................................................................................ 28 10. FZ200BS MANAGEMENT TIP...............................................................................................................................30 10-1. FZ200BS DEVICE TYPE SET-UP ...................................................................................................................... 30 10-2. ZIGBEE NETWORK CONFIGURATION................................................................................................................... 30 10-3. [SET-UP] TARGET DEVICE & TRAFFIC............................................................................................................... 31 10-4. START MESSAGE........................................................................................................................................... 32 10-5. RESET OPTION............................................................................................................................................... 34 12 1. Product components Model Name FZ200BS WE 2405TO CD FZ200BS Manual VERSION 0.1.0 Pictures Qty 1EA 1EA 1EA If you find any of above components is defective, or not included in the package, please contact the seller you purchased. 13 2. Product Appearance FZ200BS Manual VERSION 0.1.0 3. USB Interface
< Figure 2 Details and Dimension of FZ200BS >
Signal Name Description STATUS (DCD) Status Indication TX RX GND Transfer Data(Data Output) Received Data(Data Input) Ground ERROR (DTR) Status Indication OK (RTS) Status Indication 14 4. Dip Switch & Interface Socket FZ200BS Manual VERSION 0.1.0 FEATURES ON OFF BASIC SET 1 2 3 4 Do not use Do not use
Firmware Download Firmware Download Select Do not use Mode
Operation Mode
<Table 4-1 Features of Dip Switch >
OFF
NO. Port Description 1 2 3 4 5 6 7 8 9 10 11 12 VCC(3.3V) 3.3V Output Port ADC GPIO_0 GPIO_1 GPIO_2 GPIO_3 GPIO_4 GPIO_5 GPIO_6 GPIO_7 GND KEY Analog Data Input Port Digital Data Input / Output Port Digital Data Input / Output Port Digital Data Input / Output Port Digital Data Input / Output Port Digital Data Input / Output Port Digital Data Input / Output Port Digital Data Input / Output Port Digital Data Input / Output Port Ground Digital Data Input Port
< Table 4-2 Features of Interface Socket >
15 5. LED Indication / Reset Switch FZ200BS Manual VERSION 0.1.0 LED Power LED State Description Power Input Red Power LED is lit. STATUS LED Create a network or networks involved in the case, Status LED flashes about Network Creation one second intervals. or Participation Did not create the network or the network did not participate in the case, Status LED blinks rapidly. Status LED If the target is set, the Status LED is lit Target Setting If you have not set a target of approximately 1 second intervals Status LED blinks. Check the AT Command Mode is turned off if Operation Mode the Status LED OK LED Check data If data transmission is completed, the transmission OK LED blinks once. Check the AT Command Mode if the OK LED is Operation Mode lit. Check data transmission ERROR LED If you did not complete the data transmission has ERROR LED flashes once Check the AT Command Mode if the ERROR LED Operation Mode is lit. 16 FZ200BS Manual VERSION 0.1.0 6. Product Performance List Specification Zigbee Spec. Zigbee 2006 Specification Support Communication Distance 120 M Frequency Range Sensitivity Transmit Power Input Power Current Consumption Operating Temperature Max Operating Temperature 2405~2480MHz
-98 dBm 6 dBm 5V 00 mA (Max)
-20 - +50
-30 - +80 Communication Speed 9,600 bps ~ 230,400 bps Dipole Antenna (4 dBi) USB Antenna Interface 7. Current consumption Device type Coordinator Router End Device Wake-up Low power consumption mode1 Low power consumption mode2 Low power consumption mode3 Current Consumption Low Power Consumption mode Data transmission
2mA 2mA 2mA 40mA 40mA 40mA
8. Set value of Product 17 FZ200BS Manual VERSION 0.1.0 List Initial set value Device Name Device Type Device Channel Device Transmit Power FZx00 Vx.x.x ROUTER 0B 00 UART (baud rate-data bit-parity bit-stop bit) 115200 (8, N, 1 fixed) KEY Option ADC Option Count Option GPIO Option Internal Time ACK Option Retry Option Power Mode Reset Option Target Device Address Link Quality Option Start Message Option Debug Message Option Battery Low Option Quick Low Power Entry 0(Disable) 0(Disable) 0(Disable) 0(Disable) 10 0(Disable) 9 1 0(Disable) 0000000000000000 0(Disable) 1(Enable) 0(Disable) 0(Disable) 0(Disable) To change the set values of FZ200BS, use PC Software (Window HyperTerminal, Firmtech configuration program) after connecting FZ200BS to PC with AT Command. Note: Please, refer to the contents in 9. Uses Guide or FZx00_Appendix_2_GUI for further information on Set-up Modification. 9. USES GUIDE The following is a procedure for FZ200BS Set-up using Serial communication (HyperTerminal) 18 FZ200BS Manual VERSION 0.1.0 Program. The signal speed of FZ200BS is basically 115200bps. 9-1. Serial Communication (Hyper Terminal) Program Execute FZ200BS first power ON. Using a USB virtual COM Port FZ200BS By using the device's power is not ON unless you can not run the HyperTerminal. Select [Start][All Programs][Accessories][Communication][Hyper Terminal] in order, and then a window for Connection Set-up comes up. Put a name in the name blank, and click the OK button. When a window for Connection target comes up, select COM ports connected to FZ200BS, and click the OK button. 19 FZ200BS Manual VERSION 0.1.0 Select each blank as below Bit/sec: 115200, data Bit: 8, Parity: None, Stop Bit: 1, Flow Control: None, and click the OK button. Hyper Terminal is executed. Hyper Terminal simply does not show any letters inputted. If you check on Echo typed characters locally to get to know what letters are inputted, the Recommends between FZ200BS and Hyper Terminal are mixed up. Do not check this. 20 FZ200BS Manual VERSION 0.1.0 9-2. Set-up FZ200BS Device Type Zigbee Device is classified as Coordinator, Router, and End Device by objective of its operation. There should be Coordinator in the Zigbee Network. A Coordinator should exist in a Zigbee Network. Coordinator manages the Network in the Zigbee Network. Router extends the Network in the Zigbee Network. End Device participates in the Zigbee Network using low power consumption. Router and End Device are automatically participated in the Network once Coordinator configures the Zigbee Network. Note : Please, refer to the following when you try to configure the Zigbee Network. 1. Do not turn the power of the Device set to Coordinator ON before all devices types are set. 2. If you already set the rest type of each Device and operate them with the Coordinator that the power is turned on, execute Factory Reset for the devices set to Coordinator and Router. Before the Factory reset, the power of the Coordinator and the Router should be turned OFF. After the Factory reset is done, set each Device to Coordinator and Router, and turn on the power of all devices. The Zigbee Network shall be properly configured. 21 FZ200BS Manual VERSION 0.1.0 3. Do not change the Device Type of FZ200BS once the Zigbee Network is configured. It is better to set Coordinator and Router again(Factory Reset) if the Device Type of FZ200BS is changed after the Zigbee Network is already configured. See if the Zigbee Network is configured before resetting FZ200BS to initial set value. The FZ200BS reset automatically participates in the Zigbee Network if the Zigbee Network still exists there. 9-2-1. FZ200BS End Device Set-up
(1) The Initial set value of FZ200BS is ROUTER.
(2) FZ200BS device and the PC is connected and powered ON. After running the HyperTerminal program, FZ200BS When you reset the serial port "ROUTER START ERROR" is output. ROUTER START ERROR means that The Zigbee Network Participation is failed. ROUTER START OK is output if the Zigbee Network is configured.
(3) Input +++ in Hyper Terminal.
(4) If OK is outputted from FZ200BS, AT-Command can be used from then. If OK is not output even after inputting +++, press Enter key and input +++ again, or reboot the device and input +++.
(5) After inputting AT+SETEND into Hyper Terminal, press Enter Key. 22 FZ200BS Manual VERSION 0.1.0
(6) If OK is output from FZ200BS, reboot FZ200BS by inputting ATZ.
(7) END START ERROR is output at the moment when FZ200BS is rebooted. END START OK is output if the Zigbee Network is successfully configured.
(8) Now, End Device of FZ200BS set-up is completed. Turn the Power of the End Device OFF, and set other devices. 9-2-2. FZ200BS Router Set-up
(1) The initial set value of Device is ROUTER. The initial set value of FZ200BS is ROUTER. The following is a procedure of purposely setting Device to Router by using AT-Command. However, Device originally operates as Router without intentional setting.
(2) FZ200BS device and the PC is connected and powered ON. After running the HyperTerminal program, FZ200BS When you reset the serial port "ROUTER START ERROR" is output. ROUTER START ERROR means that the Zigbee Network participation is failed. ROUTER START OK is output if the Zigbee is successfully configured Network.
(3) Input +++ into Hyper Terminal.
(4) If OK is output from FZ200BS, AT-Command can be used from then. If OK is not output even after inputting +++, press Enter key and input +++ again, or reboot the device and input +++.
(5) Input AT+SETROUTER through Serial port of PC and press Enter key. 23 FZ200BS Manual VERSION 0.1.0
(6) If OK is output from FZ200BS by inputting ATZ, reboot FZ200BS.
(7) ROUTER START ERROR is output at the moment when FZ200BS is rebooted. ROUTER START OK is output if the Zigbee Network is successfully configured.
(8) Now, Router of FZ200BS Set-up is completed. Turn the Power of the End Device OFF, and set other devices. 9-2-3. FZ200BS Coordinator set-up
(1) The initial set value of FZ200BS is ROUTER.
(2) FZ200BS device and the PC is connected and powered ON. After running the HyperTerminal program, FZ200BS When you reset the serial port "ROUTER START ERROR" is output. ROUTER START ERROR means that the Zigbee Network participation is failed. ROUTER START OK is output if the Zigbee Network is successfully configured.
(3) Input +++ into Hyper Terminal.
(4) If OK is output from FZ200BS, AT-Command can be used from then. If OK is not output even after inputting +++, press Enter key and input +++ again, or reboot the device and input +++.
(5) Input AT+SETCOORD through Serial port of PC and press Enter key
. 24
(6) If OK is output from FZ200BS by inputting FZ200BS Manual VERSION 0.1.0 ATZ, reboot FZ200BS.
(7) COORD START OK is output at the moment when FZ200BS is rebooted.
(8) Now, Coordinator of FZ200BS Set-up is completed, and the Zigbee Network is successfully configured. Turn the Power of the Coordinator Device OFF, and set other devices. 9-3. The Zigbee Network Configuration using FZ200BS Try to configure the Zigbee Network after setting the Type for each Device. 9-3-1. The Zigbee Network configuration Coordinator leads the Zigbee Network Configuration. Coordinator manages the Zigbee Network.
(1) Coordinator to set up the device's power is ON. After running HyperTerminal, FZ200BS will reset.
(2) COORD START OK and TARGET NON are output. TARGET NON means that FZ200BS has yet to set its target device.
(3) Zigbee Network is configured by Coordinator.
(4) From then, Zigbee Network Participation and Extension is possible by Router and End Device.
(5) Coordinator can transmit Data. 9-3-2. Zigbee Network Extension Router performs the Zigbee Network Extension. Communication distance and route can be extended because of the Zigbee Network Extension by Router. The number of End Device which participates in the Zigbee Network can be increased because of the Zigbee Network Extension by Router. Router also transmits data in the Zigbee Network, as well. 25
(1) Router to set up the device's power is ON. After running FZ200BS Manual VERSION 0.1.0 HyperTerminal, FZ200BS will reset.
(2) ROUTER START OK and TARGET NON are output. TARGET NON means that FZ200BS has yet to set its target device. If ROUTER START ERROR is output, which means that no Zigbee Network is around, reset the Device or check if the Coordinators status is okay.
(3) Router participates in the Zigbee Network and extends the Zigbee Network.
(4) Router can transmit Data. 9-3-3. Zigbee Network Participation End Device participates in the Zigbee Network. End Device performs data transmission in the Zigbee Network. End Device supports Low power consumption mode.
(1) END DEVICE to set up the device's power is ON. After running HyperTerminal, FZ200BS will reset.
(2) END START OK and TARGET NON are output. TARGET NON means that FZ200BS has yet to set its target device. If END START ERROR is output, which means that no Zigbee Network is around, reset the Device or check if the Coordinators status is okay.
(3) End Device participates in the Zigbee Network, and is ready to transmit Data. 9-4. Target device set-up To transmit Data, setting a target device, which is supposed to receive the Data, is required in terms of the Zigbee Network using FZ200BS. 26 FZ200BS Manual VERSION 0.1.0 With no target device, data transmission cannot be done even if data is inputted. To set a target device, you need to know an IEEE ADDRESS of the Device. 9-4-1. Searching for an IEEE ADDRESS of Coordinator
(1) Input +++ through Serial port of PC while a Device operates. With Inputting +++, the mode of FZ200BS(Coordinator) switches from operation mode to AT-command mode. Data transmission becomes possible when FZ200BS is in an operation mode. Users can control FZ200BS when the device is in an AT-command mode.
(2) OK is output from FZ200BS, input AT+GETLOCAL through Serial port of PC and press Enter Key.
(3) COORD,001551000000000B,0000 is output from the Device. COORD : It is the Device Type of FZ200BS. 001551000000000B : It is an IEEE ADDRESS of FZ200BS. 0000 : It is a NETWORK ADDRESS.
(4) The IEEE ADDRESS 001551000000000B is required for the target device set-up. 9-4-2. Target device set-up Set a target device with the IEEE ADDRESS that is mentioned on the previous page.
(1) Devices in the active state, FZ200BS (router) will reset 27
(2) FZ200BS outputs a message TARGET NON, which means that its target device is not set. FZ200BS Manual VERSION 0.1.0
(3) Input +++ through Serial port of PC while FZ200BS operates. OK is output. From then, its target device set-up is possible with AT Command.
(4) After OK is output from FZ200BS AT+SETTARGET 001551000000000B through Serial of PC and press Enter Key. AT+SETTARGET : It is a command to save the target devices address. 001551000000000B : It is the target devices IEEE ADDRESS
(5) OK is output from FZ200BS which means that the command for saving target device is cognized. If ERROR is output, the command inputted is wrong.
(6) Re-start FZ200BS by inputting a command ATZ or turn the power of FZ200BS off and on, again.
(7) FZ200BS is re-started and outputs a message TARGET OK.
(The target device must be power ON.) Now, the target device set-up using its address is completed. If TARGET ERROR is output, FZ200BS which has an IEEE ADDRESS 001551000000000B does not exist in the Zigbee Network or the address saved is wrong. 9-5. Serial Data Transmission Data transmission is done in the Zigbee Network. Data is transmitted to the target device 001551000000000B that is set on the previous page. IEEE ADDRESS of the Device(Router) which is supposed to transmit the data is 0015510000000005. 28 FZ200BS Manual VERSION 0.1.0
(1) Coordinator to set up the device's power is ON. After running HyperTerminal, FZ200BS will reset. The Zigbee Network is configured by Coordinator.
(2) Router to set up the device's power is ON. After running HyperTerminal, FZ200BS will reset. The Device participates in the Zigbee Network. Its target device is automatically set. A message TARGET OK is output. If, TARGET NON or TARGET ERROR is output, its target device is not set. Do the 9-4-2.Target device set-up, again.
(3) Input 1234567890 into Hyper terminal(Router) and press Enter(0x0D) key. FZ200BS transmits data (1234567890) inputted, Carriage Return(0x0D), and Line Feed(0x0A) at the same time. (Do not input 0x0A. 0x0A is automatically added by FZ200BS.)
(4) Serial Data1234567890 is output.(Coordinator) Input Serial data of Serial port of FZ200BS. After inputting the serial data, press Enter key. 53 bit including Enter key is a maximum length of Serial data can be transmitted by FZ200BS. The Serial data sent from a Device is output through Serial port of its target device. To transmit the other forms of data after Serial data transmission, you should wait until you get the Serial Datas result value. In other words, the other data transmission becomes possible after OK LED or 29 ERROR LED shows its status. FZ200BS Manual VERSION 0.1.0 10. FZ200BS Management TIP Refer to the following to configure Zigbee Network properly in terms of data transmission and Controls. 10-1. FZ200BS Device Type Set-up
(1) End Device Set-up Set FZ200BS to End Device before Coordinator and Router is set. (AT+SETEND) Turn the power of the FZ200BS OFF.
(2) Router Set-up Set FZ200BS to Router before Coordinator is set. (AT+SETROUTER) Turn the power of the FZ200BS OFF.
(3) Coordinator Set-up Set FZ200BS to Coordinator. (AT+SETCOORD) Turn the power of FZ200BS OFF. 10-2. Zigbee Network Configuration 30 FZ200BS Manual VERSION 0.1.0
(1) Turn the power of FZ200BS set to Coordinator ON.
(2) Turn the power of Router and End Device which are supposed to make 1 Depth ON.
- You can create Devices in 1 Depth up to 8.
(3) Turn the power of Router and End Device which are supposed to make 2 Depth ON.
- You can create Devices in 2 Depth up to the number of Router in 1 Depth * 8.
- Devices are automatically created in 1 Depth if any seats are available in 1 Depth.
(4) Turn the power of Router and End Device which are supposed to make 3 Depth ON.
- You can create Devices in 3 Depth up to the number of Router in 2 Depth * 8.
- Devices are automatically created in 1/2 Depth if any seats are available in 1/2 Depth.
(5) Turn the power of Router and End Device which are supposed to make 4 Depth ON.
- You can create Devices in 4 Depth up to the number of Router in 3 Depth * 8.
- Devices are automatically created in 1/2/3 Depth if any seats are available in 1/2/3 Depth. 10-3. [Set-up] target device & traffic Set target device of each Device after the Zigbee Network is configured. Save an IEEE ADDRESS of target device by using a command AT+SETTARGET Reset the Device so that its target device set-up can be processed.
< It is not recommended that there is a lot of traffic in the Zigbee Network. >
Refer to the meanings of Traffic in terms of Zigbee Network. The Traffic is caused by Zigbee Device which performs data transmission in the Zigbee Network, Zigbee Device which performs data transmission to get its target device, Zigbee Device which transmits data to its target device ACK data for checking if Zigbee Device transmits data its target device properly, and Transmitted data for checking if the Zigbee Network works properly. There is no traffic in case of Coordinator and Router unless they are turned ON again. Coordinator and Router are always turned ON because they intermediate Devices. In case of End Device, a lot of traffic is caused because the power of End Device is turned ON and OFF repeatedly. 31 FZ200BS Manual VERSION 0.1.0 If there are a lot of Nodes in the Zigbee Network, set the space of time longer for data transmission between the Nodes, Especially, in case of End Device, great caution is required.
(A space of data transmission per 10 Devices: minimum 2seconds) The Shorter the space of data transmission is, the more traffic in the Zigbee Network is caused. Do not change target device too often. When you set or change a target device, data for transmission is more created to get its route. The more data there is in the Zigbee network, the more traffic is caused. In case thatEnd Device receives ACK data after data transmission, (For control using MICOM and data re-transmission) set ACK data transmission receipt to be enabled by using a command AT+SETACK1. In this situation, more traffic in the Zigbee Network is caused in comparison. If ACK data recipe is not required after data transmission using End device (For data transmission only), set ACK data receipt to be disabled by using a command AT+SETACK0. In this situation, less traffic in the Zigbee Network is caused in comparison. Do not set target device to FFFFFFFFFFFFFFFF(Broadcast) when performing data transmission. If data is transmitted by Broadcast, all Routers in the middle transmit the data to all nodes again. The more Devices using Broadcast data exist and the more Routers in the middle exist, the more traffic is caused in the Zigbee Network. Do not use Broadcast data transmission unless it is essential. When FZ200BS performs a command to get information on Nodes participated in the Zigbee Network, a lot of traffic in the Zigbee Network is caused. Because Router cannot save information on all nodes in the Zigebee Network, the inquired data is mostly transmitted by broadcast. Broadcast data increase traffic in the Zigbee Network. In case of you need, use AT command to inquire information on nodes in the Zigbee Network. A lot of traffic in the Zigbee Network bothers data transmission and target device set-up 10-4. START MESSAGE
(1) START MESSAGE It means that FZ200BS starts to operate. START MESSAGE is output as Serial data through Serial port. If you dont want a Device to output the START MESSAGE, input AT command (AT+SETSTAMSG0). 32 FZ200BS Manual VERSION 0.1.0
(2) Sorts of START MESSAGE COORD START OK
: A Device starts as Coordinator and the Zigbee Network is configured properly. Thus, data transmission is possible. COORD START ERROR
: A Device starts as Coordinator, and the Zigbee Network Configuration is failed. In this situation, a normal Zigbee Network cannot be configured. After initializing the Device to factory set value (AT&F) and set the Device to Coordinator again, Change the Channel used. ROUTER START OK
: A Device starts as Router and the Zigbee Network is configured properly. Thus, Zigbee Network Extension and data transmission is possible. ROUTER START ERROR
: A Device starts as Router, and the Zigbee Network Configuration is failed. See if there is Coordinator around. See if there is Router participated in the Zigbee Network configured by Coordinator. See if there is channel which is the same as the one Coordinator use. END START OK
: A Device starts as End Device and the Zigbee Network is configured properly. Thus, data transmission is possible. END START ERROR
: A Device starts as Router, and the Zigbee Network Configuration is failed. See if there is Coordinator around. 33 FZ200BS Manual VERSION 0.1.0 See if there is Router participated in the Zigbee Network configured by Coordinator. See if there is Coordinator which has 8 child nodes. See if there is Router which participates in the Zigbee Network and has 8 child nodes. TARGET NON
: There is no IEEE ADDRESS of target device saved. In this case, data transmission is not possible. Set a target device to process data transmission. TARGET OK
: Target Set-up is properly done by using an IEEE ADDRESS of target device. Data transmission is possible. TARGET ERROR
: Target Set-up using IEEE ADDRESS of target device is failed. See if there is the target device in the Zigbee Network. If there is the target device participated in the Zigbee network, check if the IEEE ADDRESS of the target device is correctly saved. OK
: The message OK is output from FZ200BS when a Device switches its mode from operation mode to AT command mode.
- Use a command +++ to make the Device switches its mode from operation mode to AT command mode. The massage OK is also output when a Device switches its mode from AT command mode to operation mode.
- Use a command ATO to make the Device switches its mode AT command mode to operation mode. 10-5. RESET OPTION
(1) RESET OPTION FZ200BS operates properly in the Zigbee Network. Once the power of FZ200BS is turned ON, the device automatically participates in the Zigbee Network. After the Zigbee Network Participation, the Device outputs ROUTER START OK or END 34 FZ200BS Manual VERSION 0.1.0 START OK. Target device Se-up is possible afterwards. FZ200BS outputs ROUTER START ERROR or END START ERROR if there is no Zigbee Network around or the Device cannot participate in the Zigbee Network. Target device set-up is prior to data transmission. Turn the power of FZ200BS ON, and then the Device is participated in the Zigbee Network. If FZ200BS has its target devices Address, FZ200BS searches if its target device is participated in the Zigbee Network. If the target device of FZ200BS is participated in the Zigbee Network and the target device is properly set, TARGET OK is output. Data transmission becomes possible from then. If the target device of FZ200BS is not participated in the Zigbee Network and the target device is failed, TARGET ERROR is output. When RESET OPTION is set to be enabled with a command AT+SETRESET1 , FZ200BS fails to participate in the Zigbee Network and its target device is not properly set, FZ200BS is reset. When RESET OPTION is set to be disabled with a command AT+SETRESET0 , FZ200BS fails to participate in the Zigbee Network and its target device is not properly set, FZ200BS is put on standby for a handle by users. References Appendix_1: FZx00_AT Command Appendix_2: FZx00_GUI Appendix_3: FZx00_End Device & ADC/KEY/GPIO 35 FZ200BS Manual VERSION 0.1.0 36
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2011-07-07 | 2405 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2011-07-07
|
||||
1 | Applicant's complete, legal business name |
Firmtech co., Ltd
|
||||
1 | FCC Registration Number (FRN) |
0018771915
|
||||
1 | Physical Address |
807, 555, Dunchon-daero, Jungwon-gu, Gyeonggi-do
|
||||
1 |
Seongnam-si, N/A 462-726
|
|||||
1 |
South Korea
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
U8D
|
||||
1 | Equipment Product Code |
FZ200BS
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J****** K******
|
||||
1 | Telephone Number |
82-31********
|
||||
1 | Fax Number |
82-31********
|
||||
1 |
j******@firmtech.co.kr
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 01/03/2012 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | ZIGBEE USB ADAPTER | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
LTA Co.,Ltd
|
||||
1 | Name |
A**** C****
|
||||
1 | Telephone Number |
82-31********
|
||||
1 | Fax Number |
82-31********
|
||||
1 |
c******@ltalab.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2405.00000000 | 2480.00000000 | 0.0100000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC