user manual I. Main Functions:
1. Six function keys: SET, ALARM, LCD, UP/CH, DOWN/CF, SNOOZE. 2. 12/24 hour selectable. 3. C/F selectable 4. Indoor temperature range: 0--+50 5. Outdoor temperature range: -20 --60 6. Double alarm function 7. Snooze function, ring again after 5 minute later 8. DST function II. Key Function:
Function SET Up/CH DOWN/CF SNOOZE ALARM LCD Operation s t a n d a r d m o d e i T m e s e t A l a r m s e t Click Switch display Switch RF channel C/F switchable Backlight on On/ off alarm
-----
Hold Click Hold Click Hold enter into time setting Confirm the Setting enter into time setting Confirm the Setting enter into time setting Clear RF data
-----
one step forward 8steps/second forward one step forward 8steps/second forward one step backward 8steps/second backward One step Backward 8steps/second backward
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
Enter into LCD Brightness setting
-----
-----
-----
-----
III. Instruction of Operating 3.1 Normal states 1. Click SET key to alarm mode. 2. Hold SET key to enter into setting mode 3. Hold UP/CH key to clear out all data of current channel 4. Click DOWN/CF key to switch between C/F 5. Hold LCD key for 2 seconds to adjust LCD brightness setting, total 8 levels. 6. Click ALM key to switch the alarm on/off 7. When alarm is ringing, click SNOOZE key once to enter into snooze state, the alarm will ring again after 5 minutes 3.2 Time setting 1. Hold SET key for 2 seconds to enter into time setting 2. The setting item will flash 1 HZ 3. The sequence of time setting: 12/24HROFF/SETHourMinuteLanguageYearMonthDateExit 4. Press SET key to confirm the setting. 5. Press UP/CH key one time, the setting will go forward one step; hold the key for 2 seconds, it will run forward by 8 steps/second. 6. Press DOWN/CF key one time, the setting will go backward for one step; hold the key for 2 seconds, it will run back by 8 steps/second. 7. The system will exit automatically if no key is operated in 15 seconds. And the previous setting will be confirmed automatically. 3.3 Alarm set 1. Hold ALM key for 2 seconds to enter into alarm setting 2. The setting item will flash 1 HZ 3. The sequence of alarm setting: Hour Minute exit 4. Press UP key one time, the setting will go forward for one step; hold the key for 2 seconds, it will run forward by 8 steps/second. 5. Press DOWN/CF one time, the setting will go backward for one step; hold the key for 2 seconds, it will run back by 8 steps/second. 6. Press ALM key to confirm the setting 7. The system will exit automatically if no key is operated in 15 seconds. And the previous setting will be confirmed automatically. 8. Press ALARM key to switch alarm on/off, sequence: AL1 ON/AL2 OFFAL2 ON/AL1 9. OFFAL1/AL2AL1/AL2 OFF. the BUZZER will ring for 2 seconds as below:
a) 0 10 sec.: one BI per second b) 10 20 sec.: two BI per second c) 20 30 sec.: four BI per second d) after 30 sec.: BI continuously e) When the alarm is ringing, click SNOOZE key once to enter into snooze state, and ring again after 5 minute later; press other key to exit. IV. Power-On and reset When Power-On and reset, LCD full display for 3 seconds enter the normal state after Beep checking temperature
receive RF for 3 minutes
.Receiving RF 5.1 The receiving function of RF 1. After installing the battery and checking temperature, it will enter RF receiving state automatically for 3 minutes. 2. Under normal display mode, hold the UP/CH key for 2 seconds to clear out the channel information, and re-register 3. channel If there is no effective signal with same ID code received for the current channel in 1 hour, the temperature of that CH will shows --.-, and wait for re-register channel. At the same time to receive RF for 3 minutes, if no effective signal within 3 minutes, RF will off. And start to receive RF for 3 minutes in next hour, until receive RF or hold UP/CH key. FCC warnings This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help