LoRa Concentrator Linxdot LM-1000 Module Package contents Overview LM-1000 is a Lo Ra concentrator an easy integration into an existing capabilities. USB connection. Furthermore, It can be used in any embedded platform offering a free mini-PC router or other network equipment with Lo Ra Gateway le slot with SPI or ZOE-M8Q GPS chip is integrated on board. card with mini-PCle form factor based on SX1302, which enables demodulation and cost efficient paths which are 8xSF5-SF12 LM-1000 is a complete parallel demodulators, any time, any packet in a combination channels, and Internet-of-Things up to 16 packets
(loT) applications, 125 /250 / 500 kHz Lo Ra demodulator and demodulate of 8 different covering It can detect at and (G)FSK demodulator. 10 factors(SF5 to SF12) and spreading at any time. It targets smart metering fixed networks up to 500 nodes per square kilometer in an Lo Ra gateway solution offering Lo Ra demodulator O Lo Ra s, 8xSF5-SF1 up to 10 programmable Main features Compatible SX1302 base band processor with Mini PCl-e Edition specification with heat sink. emulates 8 x8 channel Lo Ra packet detectors, 8 x SF5-SF12 Lo Ra demodulators, 8 x SF5-SF1 O Lo Ra demodulators, one 125 /250 /
and one (G)FSK demodulator SPI interface of SX1302 to USB2. 0. with 3G/LTE card of Mini PCl-e type. down to -139dBm@SF12, BW 125 kHz. 500 kHz high-speed Lo Ra demodulator latest extra MCU to convert LoRaWAN 1.0.2 protocol. of Mini PCl-e is 3.3 V, compatible Optional built-in Voltage Tx power up to 27dBm, Rx sensitivity Supports Supports AS920). Supports Built-in Optional global license-free SPI or USB interfaces. ZOE-M8Q GPS module. frequency optional LBT (Listen-Before-Talk) function. band (EU868, US915, AS923, AU915, KR920, IN865 and LoRa Concentrator Module Linxdot LM-1000 Pin conguration Specications Fx Technology Limited | www.linxdot.com LoRa Concentrator Module Linxdot LM-1000 FCC Statement FCC standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 External Antenna with gain 2dBi(LoRa) FCC Regulatory Compliance:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
(2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
-- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. time. It targets smart metering xed networks If power exceeds the limit and the distance(Over 20cm distance in actual use between the device and user) is compliance with the requirement RF Exposure Compliance:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. Notice to OEM integrator If the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. The end product shall haves the words Contains Transmitter Module FCC ID: 2AUCLLM-1000. The device must be professionally installed. The device must be professionally installed. The intended use is generally not for the general public. It is generally for industry/commercial use. The connector is within the transmitter enclosure and can only be accessed by disassembly of the transmitter that is not normally required. The user has no access to the connector. Installation must be controlled. Installation requires special training. Any company of the host device which installs this modular with unlimited modular approval should Any company of the host device which installs this modular with unlimited modular approval should perform the test of radiated & conducted emission and spurious emission, etc. according to FCC part 15C: 15.247 , 15B Class B requirement, only if the tests result comply with FCC part 15C: 15.247 , 15B Class B requirement, then the host can be sole legally. When the module is installed inside another device, the user manual of the hose contain below 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired 2) This device must accept any interference received, including interference that may cause undesired operation. Fx Technology Limited | www.linxdot.com LoRa Concentrator Module Linxdot LM-1000 UKCA Statement Operating Temperature: -15C to 40C This device in compliance with the essential requirements and other relevant provisions of UK Radio Equipment Regulations (SI 2017/1206); UK Electrical Equipment (Safety) Regulations (SI 2016/1101); and UK Electromagnetic Compatibility Regulations (SI 2016/1091). All essential radio test suites have been carried out. This product is a xed location. To comply with RF exposure requirements, a minimum separation This product is a xed location. To comply with RF exposure requirements, a minimum separation distance of 20cm must be maintained between the users body and the device Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna. This device in compliance with the essential requirements and other relevant provisions of UKCA. All essential radio test suites have been carried out. 1.Adapter shall be installed near the equipment and shall be easily 1.Adapter shall be installed near the equipment and shall be easily accessible. 2. The plug considered as disconnect device of adapter. Operation Frequency: 864.1MHz, 864.3MHz, 864.5MHz, 868.1MHz, 868.3MHz, 868.5MHz LoRa: 0.0085W Manufacturer: FX Technology Limited Address:2 Stone Buildings, Lincoln's Inn, London, WC2A 3TH United Kingdom E-mail: support@fxtec.com Fx Technology Limited | www.linxdot.com LoRa Concentrator Module Linxdot LM-1000 Fx Technology Limited | www.linxdot.com