FCC ID: 2BF3F-KJR-120T2 Wired Controller

by: GD Midea Heating & Ventilating Equipment Co., Ltd. latest update: 2026-03-23 model: KJR-120T2

One grant has been issued under this FCC ID on 03/23/2026 (this is one of two releases in 2026 for this grantee). Public details available include frequency information, internal & external photos, and manuals. some products also feature user submitted or linked password defaults, troubleshooting guides, instructions, drivers, & warrantee terms.
permalink for this FCC identifier
|
Get Slack Alerts
|
|   
eg for Slack usage
manual
app s submitted / available
1 Users Manual pdf 5.13 MiB March 23 2026
1 Attestation Statements pdf March 23 2026
1 Block Diagram Block Diagram pdf March 23 2026 confidential
1 Circuit Diagram Schematics pdf March 23 2026 confidential
1 Cover Letter(s) pdf March 23 2026
1 External Photos pdf March 23 2026
1 Internal Photos pdf March 23 2026
1 ID Label/Location Info pdf March 23 2026
1 Cover Letter(s) pdf March 23 2026
1 RF Exposure Info pdf March 23 2026
1 Technical Description Operational Description pdf March 23 2026 confidential
1 Test Report pdf March 23 2026
1 Test Setup Photos pdf March 23 2026

 

Scan the QR code to read the manual in different languages INSTALLATION

& OPERATION MANUAL Wired Controller Thank you very much for purchasing our product. Before using your unit, please read this manual carefully and keep it for future reference. This manual gives detailed description of the precautions that should be brought to your attention during operation. In order to ensure correct service of the wired controller please read this manual carefully before using the unit. For convenience of future reference, keep this manual after reading it. CONTENTS 1 GENERAL SAFETY PRECAUTIONS 1.1 1.2 About the documentation For the user 2 3 BASIC PARAMETERS ACCESSORIES LIST 4 OPERATION INSTRUCTIONS 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 Control Panel Explanation Basic Operation Mode Fan speed Swing Timer Self-cleaning Midea ETA function Air quality monitoring Function settings 01 02 04 04 5 6 8 9 10 12 16 17 18 19 5 OTHER FUNCTIONS AND SETTINGS APP control Home leaving mode ECO setting by human sensor Silent IDU Temperature unit setting Room temp.display IDU lighting Backlight time Backlight brt The temperature setting in auto mode Key lock Daylight saving time Date and time setting Language One-to-more Fault Prompt 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14 5.15 5.16 6 FAQ 7 INSTALLATION 7.1 7.2 Installation Precautions Installation Method 8 ENGINEERING SETTINGS 8.1 8.2 8.3 8.4 8.5 8.6 Parameter settings of the wired controller Engineering Menu Wired controller Configuration IDU settings ODU settings System Operating Status Query 23 23 28 29 30 31 32 33 34 34 35 36 37 38 40 41 42 43 46 47 55 55 56 57 58 67 67 1 GENERAL SAFETY PRECAUTIONS 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow them carefully. All activities described in the installation manual must be performed by an authorized installer. 1.1.1 Meaning of warnings and symbols Indicates a situation that results in death or serious injury. DANGER DANGER: RISK OF ELECTROCUTION Indicates a situation that could result in electrocution. DANGER: RISK OF BURNING Indicates a situation that could result in burning because of extreme hot or cold temperatures. Indicates a situation that could result in death or serious injury. WARNING 01 Indicates a situation that could result in minor or moderate injury. CAUTION Indicates a situation that could result in equipment or property damage. NOTE i INFORMATION Indicates useful tips or additional information. 1.2 For the user If you are not sure how to operate the unit, contact your installer. The appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children must be supervised to ensure that they do not play with the product. Do NOT rinse the unit. This may cause electric shocks or fire. CAUTION 02 NOTE Do NOT place any objects or equipment on top of the unit. Do NOT sit, climb or stand on the unit. Units are marked with the following symbol:

This means that electrical and electronic products may not be mixed with unsorted household waste. Do not try to dismantle the system yourself: the dismantling of the system, treatment of the refrigerant, of oil and of other parts must be done by an authorized installer and must comply with applicable legislation. Units must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences the environment and human health. For more information, contact your installer or local authority. for 03 2 BASIC PARAMETERS Items Rated voltage Wiring size Operating environment Humidity Description DC 18 V RVVP-0.5mm2 2 23 F ~ 109.4 F RH90%

3 ACCESSORIES LIST No. 1 2 3 4 5 6 7 Name Wired controller Philips head screw M4 25 Installation and Operation Manual Plastic support bar Bottom cap of the wired controller Round head screw ST4 20 Plastic expansion pipe Quantity 1 2 1 2 1 4 4 04 4 OPERATION INSTRUCTIONS 4.1 Control Panel Explanation Display Up Left Enter Down Right 05 On/Off Menu Information Back 4.2 Basic Operation 1. On/Off Press " On/Off ". The screen/operation button will light up and the device will start. Under one-to-more individual control, the screen will not off when the On/Off button is pressed. Press " On/Off " again. The screen/operation button will be off, and the device will shutdown. Press " Menu " to enter the menu selection screen. Press " Back " to return to the previous menu Press " " " " to adjust the fan speed. Press " " " " to adjust the temperature and humidity. 2. Menu 3. Back 4. Left/Right 5. Up/Down 6. Enter Press " " to wake up the screen. 7. Information Press " Information " to view error codes. F 80 Set temperature display Timer off Cool Auto Secondary Fan WiFi Indoor temp. Timer on Heat Dry Filter blockage Midea ETA function Home leaving mode Vertical swing Horizontal swing 06 Sterilization Aux heater 3D circulating air Blow on people Silent IDU Fault prompt Schedule Sleep ECO Comfort Avoid people Backup running Key lock Lock mode Rapid cooling Rapid heating Air quality monitoring:good,middle,poor 07 4.3 Mode Select the mode on the menu and press " " for confirmation. After entering the mode, press " " or " " to select the operating mode, and press " " for confirmation. or press " Back " to exit. Mode conflict:

1. When the system detects any mode conflict, the main screen of the wired controller will display a message indicating that no heating or cooling option is available. 2. All IDUs in the same air conditioning system can only operate in the same mode (such as cooling and heating). A conflict will occur if the IDUs operate in different modes. Therefore, make sure that the operating mode of all IDUs is the same. 08 ModeOFFCool Basic Operation Mode Fan speed Swing Timer Self-cleaning Midea ETA function Air quality monitoring Function settings 4.4 Fan speed Select the fan speed on the menu, and press " " for confirmation. After entering the fan speed interface, press " " or " " to select the operating speed, or press " Back " to return to the menu. CAUTION Depending on IDU models, 3 speeds or 7 speeds are supported. With efficiency ensured, the air conditioner may adjust the fan speed depending on the indoor temperature, leading to a difference between the real-time fan speed and the set one or causing the fan to stop. This is normal. After the fan speed is set, it takes time for the air conditioner to respond. It is normal if the air conditioner does not respond to the setting immediately. 09 Fan speed Fan speedAutoOFF Parameter settings of the wired controller Engineering Menu Wired controller Configuration IDU settings ODU settings System Operating Status Query 4.5 Swing Select the Horizontal or Vertical swing function on the menu, and press

" "for confirmation. After entering the swing interface, press " "

" "" " or " " to adjust the swing angle, or press " Back " to return to the menu. CAUTION Some IDUs do not support the swing feature. When the unit is off, the wired controller automatically shuts louvers of the air outlet. 10 Vertical swingVertical swingAutoAutoOFF Independent swing Select the Vertical swing function on the menu, and press " " for confirmation. After entering the swing interface, press " " or " " to select the Louver to be controlled, and press " " to adjust the swing angle. CAUTION Independent swing only applies to IDUs with an independent swing device. 11 Individual swingLouver 1Louver 2Louver 3Louver 4OFFVertical swing 4.6 Timer Select the timer function on the menu, and press " " for confirmation. After entering the timer interface, press " " or " " to select the corresponding timer, and press " " to start function setting. 1. Timer off : Enter the timed off interface, press " " or " " to set the power-off time, press " " or " " to switch minutes and hours,and press" " for confirmation and return to the home page to display the timer period. 2.Timer on : Enter the timed on interface, press " " or " " to set the power-on time, press " " or " " to switch minutes and hours,and press" " for confirmation and return to the home page to display the timer period. 3.Menu-schedule: Enter the menu-schedule interface. You may turn on more than one schedule. When a schedule is enabled, the air conditioner will go on and off at the specific times. The parameters and operation cycles of all schedules are configurable. 12 TimerTimer30min2.5hTimer OFFTimer ONMenu-scheduleDelayed OFFOFF Menu-schedule Menu-schedule include three regular schedules(the first,second and third) and simple schedule, you can set the Schedule state on/off to enable or not, the Cycle, and the Set cmds. Press " " or " " to switch the set object, and press " " to switch the settings. Holiday setting You can choose one or more days as a holiday. After a holiday is set, the air conditioner will not execute the Menu-schedule during the holiday. 13 Menu-scheduleschedule1schedule2schedule3Simple ScheduleSchedule 1Schedule stateCycleSet cmdsONWork day Set cmds

(1) Simple Schedule You can set up to five cmds, each of which contains the time and power-on/off information. Press " " or " " to switch the set object, and press " " or" "to switch the settings. Upon the setting, press

" " or " Back " to save the settings and return.

(2) Schedule You can set up to five cmds, each of which contains the time, mode, fan speed and set temperature. Press " " or " " to switch the set object, and press " " or" " to switch the settings. Upon the setting, press " "

or " Back " to save the settings and return. 14 Set cmdsSet cmds00:0000:0005:0079.0-82.0379.079.012-79.082.070500ON: CAUTION There should not be more than one schedule act at the same time. Otherwise, a conflict may occur. Complete the date setting before the first schedule setting. Delayed off This function is only effective after the schedule is enabled. After delayed off is set, the air conditioner will delay its shutdown in accordance with the set delay based on the original schedule power-off time. CAUTION Delayed off is one-off. After executing a power-off delay act, you have to set another delayed off act to execute such function again. 15 4.7 Self-cleaning Select the self-cleaning function on the menu. The self-cleaning process takes approximately 50 minutes and falls into four steps:

Pretreatment Icing De-icing and Rinsing Drying CAUTION You can quit the timer by long pressing " " to stop self-cleaning or pressing " " to stop directly. Some models do not have self-cleaning function. For details, please refer to the manual of IDU. When self-cleaning is enabled, all IDUs (sharing the same ODU) start the process of self-cleaning. During the process of self-cleaning, the IDUs may blow out cold or hot air. 16 Self-cleaningSelf-cleaning for 25 minutesLong press cancel 4.8 Midea ETA function Select the Midea ETA function on the menu, and press " " to enable or disable the Midea ETA function. The Midea ETA function is real-time energy saving. 17 Midea ETA Midea ETAOFFON 4.9 Air quality monitoring Select the air quality monitoring function on the menu, and check the air quality indicators such as AQI, PM2.5 and CO2 in real time. Indoor air quality monitoring requires adequate configuration of the IDU. 18 CO2PM2.5HCHO1000ppm75g/m 00001mg/m Air quality monitoringAir quality monitoring 4.10 Function settings Select the function setting on the menu, and press " " for confirmation. After entering the function setting interface, press " " or " " to switch the function, and press " " to enable the selected function. Sterilization: After sterilization is enabled, the home page will show a sterilization icon " ". CAUTION It works only with the IDU with sterilization feature. The sterilization module stops when the swing function is enabled, and does not resume operation until the swing function is disabled. 19 SettingSettingEcoSterilizationSleepWind sensing...ONOFFOFFOFF Sleep: After sleep is enabled, the home page will show a sleep icon" ". The sleep function is only applicable to cooling and heating modes and unavailable for auto, dry and fan modes. With sleep enabled, it will be cancelled after manual power-off or mode switching. You have to re-enable this function. Aux heater: The auxiliary heater has four modes:

Auto Operation of Auxiliary Heater, Auxiliary Heater Enabled, Auxiliary Heater Disabled, and Auxiliary Heater Used Independently. 20 Aux heater can only enabled in Heat mode CAUTION Auto Operation of Auxiliary Heater: Upon power on, the air conditioner will determine whether to start the auxiliary heater automatically based on the ambient temperature in heating mode. At this moment, the air conditioner operates in "Auto Operation of Auxiliary Heater" mode. Auxiliary Heater Used Independently: The auxiliary heater can be used independently without starting the compressor. It only applies to certain customized models. The auxiliary heater can only be started in heating mode. The auxiliary heater is an additional heating component to the air conditioner, but the power consumption will increase after the auxiliary heater starts working. Powerful operation: After powerful operation is enabled, the IDU will accelerate cooling/heating. Powerful operation is only available for cooling or heating mode. After powerful operation is enabled, the maximum runtime of the IDU is 30 minutes. After powerful operation is disabled, the IDU will be controlled normally. Power operation will quit in case the operating mode or fan speed is changed. 21 Wind sensing of smart panel : The wired controller can set the IDU air flow to "Comfortable" or "Off". If the air flow is set to

"Comfortable", the fan speed and swing angle of the IDU will automatically adjust to a relatively comfortable level. This function only applies to IDUs with air flow setting feature. 22 SettingStrong modeWind sensing of smart panelOdu silenceTemp unit settingONOFF 5 OTHER FUNCTIONS AND SETTINGS 5.1 APP control APP control C7 C7 D4 When smart networking is enabled, you can control your smart devices with APP. 1Smart home appliances networking guidelines 1.Download the SmartHome App On an app market (Google Play Store, Apple App Store), search for and nd the SmartHome app. Download and install it on your phone. You can also download the app by scanning the QR code below. SmartHome*

Download the app

& activate product 23 SettingOFFTempe in auto modeLockIntelligent networkKey tone prompt 2.Register and log in Open the SmartHome app, and create a new account to start (you can also register through a third-party account). If you already have an existing account, use the account to log in. 3.Connect your devices to SmartHome Please make sure your mobile phone is connected to a wireless network. If it is not, go to Settings and enable wireless networks and Bluetooth. Please power on your devices. Open SmartHome app on your phone. If a message of "Smart devices discovered nearby" appears, click to add. Washing machine 24 If no message appears, select "+" on the page and select your device in the list of nearby devices available. If your device is not listed, please add your device manually by the device category and device model. Connect your device to the wireless network according to instructions on app. If the connection fails, please follow the instructions provided by the app to continue with the operation. 25 NOTE Notes on networking When networking the product, please make sure that the mobile phone is as close as possible to the product. According to the App tips, if the product only supports 2.4GHZ WiFi communication, please note that the 2.4GHz network is selected for connection. Midea recommends WiFi router SSID names contain only alphanumeric values. If special characters, punctuation marks or spaces are used it might prevent the SSID name from showing up in the available networks to join in the App. Try it and if the SSID shows up then it is ok to use, otherwise log into the router and change the SSID name. A large number of devices on the WiFi router can affect network stability, there is no way that Midea can advise a specific number limitation as this depends on router quality and many other factors. If the router or WiFi name and WiFi password change, please repeat the above process to reconnect to the network. As the product technology is updated, the content of SmartHome may change, and in SmartHome App shall prevail. the actual display 26 WARNING Warning and troubleshooting for networking failures When the product is connected to the network, please make sure that the phone is as close as possible to the product. We only support 2.4GHz band routers at present. Special characters recommended as part of the WLAN name.

(punctuation, spaces, etc.) are not It is recommended that you connect no more than10 devices to a single router lest home appliances are affected by weak or unstable network signal. If the password of the router or WLAN is changed, clear all settings and reset the appliance. The contents of App might change in version updates and actual operation shall prevail. WiFi information WiFi transmit frequency range:2.412~2.462 GHz EIRP not more than 20dbm 27 5.2 Home leaving mode When the Home leaving mode is enabled and indoor temperature reaches the set value,the air conditioner will activate cooling or heating mode. You can press " " or " " to select an item, and press " " and " " to adjust the temperature,or press" " to adjust on/off. 28 SettingEcoSterilization META setting by human sensorHome leaving modeONOFFOFF8241Home leaving mode 5.3 ECO setting by human sensor The ECO setting by human sensor is enabled when no one is detected, you can select the "Staus" and press " " to choose between automatic temperature adjustment and automatic power off modes. 1. Adjust set temp.: Press " " or " " to select the Temp.change interval or Max temp.adjust variance,and press" " to adjust the time or temperature. 2.Power OFF: Press " " or " " to select the Power-off delay time,and press" " to adjust the time. 29 SettingEcoSterilization ECO setting by human sensorWind sensing...ONOFFOFFTemp.change intervalStastus ECO setting by human sensorMax temp.adjust varianceAdjust set temp.45min4 5.4 Silent IDU After "Silent IDU" is enabled, the IDU will operate in silence. You can press " " to enable or disable the function. 30 SettingSettingStrong modeStrong modeWind sensing of smart panelWind sensing of smart panelSilent IDUSilent IDUTemp unit settingTemp unit settingONONOFFONC 5.5 Temperature unit setting The temperature unit is Fahrenheit by default. You can manually switch the unit between Fahrenheit and Celsius. You can press " " to enable or disable the temperature unit. 31 SettingSettingStrong modeStrong modeWind sensing of smart panelWind sensing of smart panelOdu silenceOdu silenceTemp unit settingTemp unit settingONONOFFOFF 5.6 Room temp.display After the Room temp.display is enabled, if you return to the home page and does not operate the device, the device will automatically display the room temperature and presents a room temperature icon. You can press " " to enable or disable the function. CAUTION In auto mode, the room temperature is displayed forcedly. 32 SettingSettingshowhideTempe in auto modeTempe in auto modeLockLockIntelligent networkIntelligent networkRoom temp. displayRoom temp. display 5.7 IDU lighting After the IDU lighting is enabled, the IDU display LED will light up. After the IDU lighting is disabled, the IDU display LED will turn off. You can press " " to turn on or off the IDU lighting. 33 SettingSettingTempe in auto modeTempe in auto modeLockLockIntelligent networkIntelligent networkIDU lightIDU lightOFFON 5.8 Backlight time The backlight time can be set to 15s, 30s,or 60s. After the setting, if the device fails to receive any command within the set backlight time, it will enter the standby interface. You can press " " to adjust the backlight time. 5.9 Backlight brt The Backlight brt has 10 levels, used to set the display brightness of the device. The brightness increases from level 1 to 10. You can press " " to adjust the backlight brightness. 34 SettingSettingONOFF15second30secondTempe in auto modeTempe in auto modeBacklight timeBacklight timeIntelligent networkIntelligent networkKey tone promptKey tone promptSettingSettingONOFFlevel6level7Tempe in auto modeTempe in auto modeIntelligent networkIntelligent networkKey tone promptKey tone promptBacklight brtBacklight brt 5.10 The temperature setting in auto mode The temperature setting in auto mode enables you to set the temperature in auto cooling/heating mode, and maintain the indoor temperature within the set range. Press " " to enter the temperature setting in auto mode, press" " or " "

to select an item, and press " " and " " to adjust the range. 35 Tempe in auto modeSet temp.limits for auto mode 7770SettingOFFTempe in auto modeLockIntelligent networkKey tone prompt 5.11 Key lock The key lock serves to prevent mis-operation of the children. After it is enabled, the buttons of the device will be locked and cannot be operated until the key lock is unlocked. Press " " and " " at the same time to enable the key lock, and press

" " and " " at the same time to disable the key lock. 36 SettingIntelligent network Tempe in auto modeKey tone promptKey LockOFFKey LockPress[ ]and[ ]at the sametime for 3seconds to on oroff the key lockfunction 5.12 Daylight saving time You can enable or disable daylight saving time, and set the start time and end time. Find daylight saving time in the function setting interface, and press " " to enter the setting interface. Then, press " " or " " to set the date and time, and press " " to switch. After the setting, press" Back " to return for settings to take effect. 37 Daylight saving timeDaylight saving timeStart timeStart timeEnd timeEnd time5/235/23OFFON9/239/23 5.13 Date and time setting Date and time You can select the network time (Internet connection required) or manually set the time. Find the date and time in the function setting interface, find the time display mode, and press " " to enter the setting interface. Then, press

" " and " " to set the date and time, and press " " or" " to switch. After the setting, press " " or" Back " to return for settings to take effect. 38 24hTime format Use network dateDateTimeOFF2021/5/2309:00AM Date23day2021year5mon Time display Time can be displayed in 12-hour or 24-hour format. Find the date and time in the function setting interface, find the time display mode, and press " " to enter the setting interface. 39 2312Time settingTime setting23Minute12oclockTime formatAMMinuteoclock 5.14 Language You can enter the language to select your preferred language, the system will enter in the currently selected language. Supported languages: English, Chinese (Simplified), Arabic, Spanish, Turkish, Portuguese, Korean, Russian, Italian, Polish, French, Chinese (Traditional), German, Georgian. 40 SettingDaylight... EnglishDate &...AboutSpanishLanguagePortekizceEnglishLanguage 5.15 One-to-more One wired controller can control more than one IDU (up to 16 IDUs). Under group control, the device sends commands to all IDUs in a unified manner.

(1) One to more group control Enable the one to more function by entering the Engineering Settings > IDU Settings > SiteConfig. Once this function is enabled, the system enters the one to more group control by default. Under group control, the device sends commands to all IDUs and all IDUs execute the same commands. The main interface of the device under one to more group control is the same as that under one to one control. The function in the list should be subjected to the IDU. 41 5.16 Fault Prompt Fault List C51/E9 communication fault between wired controller and IDU Press "Information" to view error codes on the homepage when fault occurs. Error display 1. In case any IDU or ODU fails, the wired controller displays the fault code. In case a communication fault occurs between the wired controller and any of the IDUs, the wired controller reports "C51". 2. The wired controller can record up to 10 faults, each of which includes the address of the faulty device, the fault code, and the time when the fault occurs. 42 Error code:C51 6 FAQ The air conditioner is not working, but prompts that neither cooling nor heating option can be set. What should I do?

The set mode is inconsistent with the operating mode of ODU. Please change the set mode to cooling/heating. The word "Filter" is displayed on the operation panel. What should I do?

Please contact the after-sales service to clean or replace the filter/heat exchanger. Please contact your local dealer What should I do if the air conditioner is not running as strongly as it should be? What are the possible causes?

Please check in the following sequence:

1. Whether the set mode is cooling or heating;

2. Whether the louvers of the air outlet face down;

3. Whether there is any barrier 20 cm around the IDU and whether the IDU is clogged and needs to be cleaned. 4. If the problem persists, Please contact your local dealer. How can I adjust the temperature on my air conditioner? What is the ideal room temperature for human comfort?

The set temperature on air conditioner should be different from the room temperature. The most comfortable temperature for summer is between 24C and 26C, and that for winter is between 18C and 20C. You may set the temperature depend on actual situations. 43 Why does the air outlet of my air conditioner drip?

The room is filled with a great amount of moisture. Please close the doors and windows. Why does the ODU of my air conditioner drip?

1. During cooling in summer, condensation water generated by the unit is discharged to the outside through the IDU drainage pipe. If the drainage pipe is close to the ODU, the condensation water may be mistaken for the water leaked from the ODU. The ODU does not drain any water during cooling. 2. During heating in winter, the ODU may be frosted. Then, the unit will defrost and the defrosted water will flow from the drainage outlet at the bottom of the ODU. This is a normal phenomenon instead of a fault of the air conditioner. To deal with this, you may contact the after-sales personnel or the installer to install an ODU drainage pipe. How should I use a wired controller? Please provide simple operation instructions. Please scan the QR code on the user manual for the operation instructions. Why does air conditioner fail to start after it is powered on?

In winter, it takes some time for your air conditioner to warm up. Please wait a few minutes. 44 Why does air conditioner keep operating after it is powered off?

After your air conditioner is powered off, there is some residual moisture inside the conditioner. It operates for a while to eliminate the moisture, so as to reduce the possibility of mould growth. Why are the air conditioner functions non-adjustable?

If the display panel presents a centralized controller icon, the air conditioner is locked. In this case, please contact the air conditioner system administrator. 45 7 INSTALLATION 7.1 Installation Precautions To ensure correct installation, read the "Installation" section of this manual. The content provided here covers warnings, which contain important information about safety that must be followed. CAUTION Entrust a local distributor or local service agent to appoint a qualified technician to perform the installation. Do not try to install the unit by yourself. Do not knock, throw, or randomly disassemble the wired controller. The wiring must be compatible with the wired controller current. Use the specified cables, and do not place any heavy object on the wiring terminals. The wired controller line is a low-voltage circuit, which cannot come into direct contact with the high voltage line or be laid in the same wiring tube together with the high voltage line. The minimum spacing of wiring tubes is 300 to 500 mm. Do not install the wired controller in corrosive, flammable and explosive environments or places with oil mist (such as a kitchen). 46 Do not install the wired controller in a wet place and avoid direct sunlight. Do not install the wired controller when it is powered on. Please install the wired controller after painting the wall;

otherwise, water, lime and sand may enter the wired controller. 7.2 Installation Method 7.2.1 Wiring requirements One-to-more and two-to-more IDU 1#

X1 X2 IDU 2#

IDU 16#

D1 D2 D1 D2 CN2 CN2 IDU 3-15#

CN2 D1 D2 CN6 L3 Ln L1 L2 Please use the shielded wire, and the shield layer must be grounded. Please use shielded wires, and the shield layer cannot be grounded. X1 X2 X1 X2 Wired controller Wired controller The IDU can realize the one-to-more and two-to-more functions.

(main-secondary wired controller needs to be set) Fig.1 47 The one-to-more function must be set for the wired controller. After the communication between the wired controller and IDU lasts 3 minutes and 30 seconds, the control can be implemented. One-to-one Applicable to bi-directional communication between wired controller and IDU. One-to-one: One wired controller controls one IDU. The parameters displayed on the wired controller are updated in real time according to changes in the parameters of the IDU. The permissible longest wiring length of the system is 200 m. Communication cables between the IDU and the wired controller (X1, X2) may be connected in reverse order. P/Q/E P/Q/E P/Q/E P/Q/E X1/X2 X1/X2 X1/X2 One-to-one One-to-one One-to-one Fig.2 48 Two-to-one Applicable to bi-directional communication between wired controller and IDU. Two-to-one: Two wired controller controls one IDU. The parameters displayed on the wired controller are updated in real time according to changes in the parameters of the IDU. Two-to-one: wired controller must be set as main or secondary. Refer to "Parameter settings C00" . The permissible longest wiring length of the system is 200 m. Communication cables between the IDU and the wired controller (X1, X2) may be connected in reverse order. P/Q/E P/Q/E P/Q/E P/Q/E X1/X2 X1/X2 X1/X2 X1/X2 Not allow X1/X2 Two to one One to one Two to one Fig.3 49 7.2.2 Installation Dimensions m m 0 2 1 m m 1 2 m m 4 8 m m 6 4 120mm 18mm 46mm 60mm Installlation of bottom cap of the wired controller. Screw hole installed on the wall,use four 4X20mm(Fig.4) Or use two M4X25 screws to install the back cover on the 86 electrical box, and use two M4X20 screw to fix to the wall. (Fig.5) Screw hole fixed on the wall, use two 4X20mm Fig.4 Screw hole installed on 86 electrical box, use two M4X25mm Fig.5 50 7.2.2 Installation Dimensions Installlation of bottom cap of the wired controller. Screw hole installed on the wall,use four 4X20mm(Fig.4) Adjust the length of the two plastic screw bars in the accessories so there is a uniform distance between the electrical box screw bar and the wall. Make sure that it is as flat as the wall when installing the screw bar to the electrical box screw bar. (Fig.6) Back cover Electrician box Signal switching wires Fig.6 Use cross head screws to fix the wired controller bottom cover in the electric control box through the screw bar. Make sure that the wired controller bottom cover is on the same level after installation, and then install the wired controller back onto the bottom cover. Fastening the screw too tightly will lead to deformation of the back cover. 51 7.2.3 Wire outlet Cutting place of upper side wire outlet A DETAIL A SCALE 2:1 Cutting place of lower side wire outlet DETAIL C SCALE 2:1 Wire clamp : For fixing wire trend DETAIL B SCALE 2:1 upper side wire outlet lower side wire outlet 52 Fig.7 m m 1 2 m m 4 8 B C x o b i n a c i r t c e E l m m 6 4 46mm 60mm Wiring hole Wall hole and wiring hole Diameter 8--10 Putty Trap Putty Trap Avoid the water enter into the wired remote controller, use trap and putty to seal the connectors of wires during wiring installation. Putty Trap Fig.8 7.2.4 Wiring Installation NOTE The switch box and control wire for 2nd generation IDUs are not attached. Do not touch the wired controller main board. 53 7.2.5 Front cover installation After adjusting the front cover, buckle the front cover; avoid clamping the communication switching wire during installation. (Fig. 9) Sensor can not be affected with damp Fig.9 Correctly install the back cover and firmly buckle the front and back covers;

otherwise, the front cover will fall off. (Fig.10) Fig.10 54 8 ENGINEERING SETTINGS 8.1 Parameter settings of the wired controller Parameters can be set in the power-on or power-off state. Hold " " and " " for 3 seconds to enter the parameter setting interface. After entering the parameter setting interface, Press " " and " " to switch the parameter. Set parameters according to the Table of Parameter Settings. Press " " to enter the parameter setting interface. Then press " " and " " to change parameter value and press " " to save changes. Press the " back " button to return to the previous page until exiting the parameter setting or exiting the parameter setting after 60s without any operation. When it is in the parameter settings page, the wired controller does not respond to any remote control signal. 55 8.2 Engineering Menu Menu Submenu Setting Mode disable Auto, Cool, Heat, Fan, Dry Lock Set temp. Speed Room temp. sensor set Room temp. sensor position Room temp. sensor Engineering Settings Interface WDC config IDU set item Set IDU address ODU set item System running status query IDU time info ODU time Other For details, see the "Wired controller Configuration"

For details, see the "IDU settings"

Set IDU address For details, see the "ODU settings"

Fault info ODU info IDU info WDC info Runtime Runtime Fan 1 runtime Fan 2 runtime Compressor 1 runtime Compressor 2 runtime Restore Settings Self-check 56 8.3 Wired controller Configuration Menu Submenu Third-level menu Default Remarks Set main and sec. wired controller main/second Master WDC 0.5 degree Temp. Adjustment or not Set temp. range/cool and heat Set temp. format: 0.5/1 0.5 Set upper and lower temp. limits in cooling/heating mode 2nd IDU:

17C-30C;

3nd IDU:

16C-30C Enable Enable Off Off 500h only V8 IDU only V8 IDU On Off Invalid only V8 IDU i E n g n e e r i n g S e t t i n g s I n t e r f a c e Rem control rcpt of wired controller Enable/Disable Wired controller Auto restore Enable/Disable Perf. degradation Filter blocked rate Filter clean reminder On/Off On/Off 00: No reminder to filter 01:500h,02:1000h, 03:2500h,04:5000h Filter reset wired controller light On/Off Separ one-to-more ctrl/swing On/Off After hours 30 min, 60 min, 90 min, 120 min, 180 min, 240 min, invalid 57 8.4 IDU settings V6 protocol IDU set item On-site settings Parameter name Parameter range Default value Remarks IDU static pressure 00/01-19/FF FF IDU static pressure is set based on the parameter value, FF (VRF unit: main board DIP of IDU;

other models: reserved) 00: 1; 01: 1.1 00: Not sound; 01: Sound 00: 56P; 01: 72P;

02: 00P; FF: IDU DIP 00: 15min; 01: 30min;

02: 60min; 03: 90min 00No 01:Yes 00: Not available; 01: Available 00: Not available; 01: Available 00: Receive; 01: Not receive 00: Not available; 01: Available Accuracy: 1C or 1F On-site air flow adjustment factor 00/01 IDU buzzer EXV opening during heating standby Mode switch interval in auto mode (min) Auto restart IDU up/down swing IDU left/right swing Remote control reception of IDU display panel IDU setting 00/01 00/01/02/FF 00/01/02/03 00 00/01 00/01 00/01 00/01 00 01 01 01 01 01 00 01 IDU auxiliary heater 00/01 Outdoor temperature to enable auxiliary heater Celsius:

-5 to 20 Fahrenheit:

23 to 68 Degrees Celsius: 15 Degrees Fahrenheit:

59 58 IDU set item Parameter name Upper automatic fan speed in cooling mode Parameter range Default value 04/05/06/07 05 Upper automatic fan speed in heating mode 04/05/06/07 06 Fan speed settings Air flow at fan speed 7 00/01 Fan speed in heating standby mode 00/01/14 Time to stop the fan of IDU in heating mode (Termal) 00/01/02/03/

04/FF IDU anti-cold wind temperature in heating mode 00/01/02/03/

FF Temperature settings Cooling return difference temperature 00/01/02/03/

04 59 01 00 01 00 00 00 Remarks 04: Speed 4; 05: Speed 5;

06: Speed 6; 07: Speed 7 04: Speed 4; 05: Speed 5;

06: Speed 6; 07: Speed 7 00: Constant speed;

01: Constant air flow 00: Termal; 01: Speed 1;

14: Fan speed before entering standby mode 00: Fan on; 01: 4min; 02: 8min;

03: 12min; 04: 16min;

FF: Main board DIP (stop the fan for Xmin; open the fan at speed 1 for 1min to detect the actual T1 temperature) Common IDU:

00: 15C; 01: 20C; 02: 24C;

03: 26C; FF: Invalid FAPU:

00: 14C; 01: 12C; 02: 16C;

03: 18C; FF: Reserved 00: 1C; 01: 2C; 02: 0.5C;

03: 1.5C; 04: 2.5C IDU set item Parameter name Parameter range Default value Remarks IDU heating temperature compensation 00/01/02/03/

04/FF 00 Temperature settings IDU cooling temperature compensation 00 VRF unit:

00/01/FF Split unit:

00/01/02/03/FF Mini VRF unit:

00/01/02/03/

04/FF Sterilization 00/01 00 Drying time at self-cleaning 00/01/02/03 00 Other settings Energy saving option VRF unit:

00: 6C; 01: 2C; 02: 4C; 03: 6C;

04: 0C; FF: Main board DIP of IDU Split unit:

00: 6C; 01: 2C; 02: 4C; 03: 8C;

04: 0C; FF: Reserved Mini VRF unit:

00: 6C; 01: 2C; 02: 4C; 03: 8C;

04: 0C; FF: Reserved VRF unit:

00: 0C; 01: 2C;

FF: main board DIP of IDU Split unit:

00: 0C; 01: 1C; 02: 2C; 03: 3C;

FF: Reserved Mini VRF unit:

00: 0C; 01: 1C; 02: 2C; 03: 3C;

04: -1C; FF: Reserved 00: Not available;

01: Plasma sterilization 00: 10min; 01: 20min;

02: 30min; 03: 40min Initial static pressure detection 00/01 00 00: Not reset initial static pressure;

01: Reset initial static pressure 60 IDU set item Parameter name Parameter range Default value Remarks Fresh air dry contact 1 -

discharge fan FAPU settings Fresh air dry contact 2 -

economizer Fresh air dry contact 3 -

humidifier 00/01 00/01 00/01 00 00 00 00: Disconnect; 01: Enable

(for FAPU only) 00: Disconnect; 01: Enable

(for FAPU only) 00: Disconnect; 01: Enable

(for FAPU only) 61 V8 protocol IDU set item Parameter name Parameter range Default value Remarks IDU static pressure 00/01-19/FF FF High ceiling 00/01/02 On-site settings On-site air flow adjustment factor 00/01/02/03/

04/05/06 Q4/Q4min air outlet closed 1 Q4/Q4min air outlet closed 2 Q4/Q4min air outlet closed 3 Q4/Q4min air outlet closed 4 IDU cooling/heating 00/01 00/01 00/01 00/01 00/01 One-to-more of wired controller enabled 00/01 IDU buzzer 00/01/02 00 00 00 00 00 00 00 00 02 IDU settings EXV opening during heating standby Mode switch interval in auto mode (min) 00/01/02/14 14 00/01/02/03 00 IDU static pressure is set based on the parameter value (refer to the IDU manual) 00: H3m; 01: 3<H4m;

02: 4<H4.5m; (H: Mounting height) 00: 1; 01: 1.05; 02: 1.1; 03: 1.15;

04: 0.95; 05: 0.9; 06: 0.85 00: Free control; 01: Close 00: Free control; 01: Close 00: Free control; 01: Close 00: Free control; 01: Close 00: Cooling and heating;

01: Cooling only 00: No; 01: Yes 00: Silent; 01: Ring;

02: Display panel only 00: 56P; 01: 72P; 02: 00P;

14: Auto regulation 00: 15min; 01: 30min;

02: 60min; 03: 90min Auto restart 00/01 01 00: No; 01: Yes 62 IDU set item Parameter name Parameter range Default value Remarks Remote control reception of IDU display panel Outdoor temperature to enable auxiliary heater Indoor temperature when auxiliary heater is on IDU settings 00/01 00 00: Receive; 01: Not receive Accuracy: 1C or 1F Accuracy: 1C or 1F Celsius:

-25 to 20 Fahrenheit:

-13 to 68 Celsius:

10 to 30 Fahrenheit:

50 to 86 Celsius:

0 Fahrenheit:

32 Celsius:

24 Fahrenheit:

75.2 T1 temperature difference when auxiliary heater is on T1 temperature difference when auxiliary heater is off 0-7 0-10 Auto dry function Upper automatic fan speed in cooling mode 00/01 04/05/06/07 3 5 00 05 0 to 7 represent 0 to 7C/F 0 to 10 represent -4 to 6C/F 00: No; 01: Yes 04: Speed 4; 05: Speed 5;

06: Speed 6; 07: Speed 7 Upper automatic fan speed in heating mode 04/05/06/07 06 04: Speed 4; 05: Speed 5;

06: Speed 6; 07: Speed 7 Air flow at fan speed 7 00/01 01 00: Constant speed;

01: Constant air flow Fan speed settings 63 IDU set item Parameter name Parameter range Default value Remarks Fan speed in cooling standby mode 01 00/01/02/03/

04/05/06/07/

14 00: Delayed fan off; 01: Speed 1;

02: Speed 2; 03: Speed 3;

04: Speed 4; 05: Speed 5;

06: Speed 6; 07: Speed 7;

14: Fan speed before entering standby mode Standby fan speed L1 range in dry mode 00/01/02/03 01 00: Fan off; 01: L1; 02: L2;

03: Speed 1 Fan speed settings Fan speed in heating standby mode 00/01/14 Time to stop the fan of IDU in heating mode (Termal) 00/01/02/03/

04 00 01 IDU anti-cold wind temperature in heating mode 00/01/02/03/

04 00 Temperature settings Cooling return difference temperature 00/01/02/03/

04 00 00 00: Termal; 01: Speed 1;

14: Fixed at Speed 1 00: Stop the fan; 01: 4min;

02: 8min; 03: 12min;

04: 16min (stop the fan for Xmin;

open the fan at speed 1 for 1min to detect the actual T1 temperature) Common IDUs (models 1, 3, 4. 6, and 8):

0: 15C; 1: 20C; 2: 24C; 3: 26C;

04: Invalid FAPU (models 2 and 7):

0: 14C; 1: 12C; 2: 16C; 3: 18C;

04: Invalid 00: 1C; 01: 2C; 02: 0.5C;

03: 1.5C; 04: 2.5C 64 IDU set item Parameter name Parameter range Default value Remarks Heating return difference temperature IDU heating temperature compensation IDU cooling temperature compensation 00/01/02/03/

04 00/01/02/03/

04 00/01/02/03/

04 Maximum indoor temperature drops D3 in dry mode 00/01/02/03/

04 Remote On/Off port logic of the IDU 00/01 Temperature settings Remote and alarm settings Remote ON/OFF control settings(reserved) 00/01 Remote OFF delay settings 00/01/02/03/

04/05/06 Alarm port logic Sterilization 00/01 00/01 65 00 00 00 01 00 00 00 00 00 00: 1C; 01: 2C; 02: 0.5C;

03: 1.5C; 04: 2.5C 00: 6C; 01: 2C; 02: 4C;

03: 8C; 04: 0C 00: 0C; 01: 1C; 02: 2C;

03: 3C; 04: -1C 00: 3C; 01: 4C; 02: 5C;

03: 6C; 04: 7C 00: Remote off (closed);

01: Remote off (open) Note: When powered off remotely, the digital display of wired controller of V8 displays d61, while that of V6 does not display this code 00: Forced OFF control;

01: ON/OFF control 00: No delay; 01: 1 min;

02: 2 min; 03: 3min;

04: 4min; 05: 5min; 06: 10min 00: Alarm when closed;

01: Alarm when open 00: Sterilization unavailable;

01: Sterilization available IDU set item Parameter name Parameter range Default value Remarks Drying time at self-cleaning 00/01/02/03 00 Remote and alarm settings Mildew-proof fan operation duration (power off in cooling/

dry mode, except power off due to faults) 00/01/02/03 00 00: 10min; 01: 20min;

02: 30min; 03: 40min 00: 40s; 01: 120s;

02: 300s; 03: 600s Dirt proof for ceiling Condensation proof 00/01 00/01 Refrigerant leakage alarm reset 00/01 ETA level in cooling mode ETA level in heating mode 00/01/02 00/01/02 Initial static pressure detection 00/01 00 00 00 00 00 00 00: Invalid; 01: Valid 00: Invalid; 01: Valid 00: Not reset; 01: Reset 00: Level 1; 01: Level 2; 02: Level 3 00: Level 1; 01: Level 2; 02: Level 3 00: Not reset initial static pressure;

01: Reset initial static pressure Energy saving option Filter ending - initial static pressure setting 00/01/.../19 00 00: 10Pa; 01: 20Pa;

02: 30Pa; ...; 19: 200Pa FAPU settings Ambient temperature when preheating is turned on 00/01/02 00 00: 5C; 01: 0C; 02: (-5)C

(for FAPU only) 66 8.5 ODU settings Parameter name Energy rating of ODU VIP IDU address Heating and air supply enabled Silence level of ODU Parameter range 40% to 100%, every 1%

0-63 00: Disable; 01: Enable Level 0 to14 8.6 System Operating Status Query V6/second generation IDU info NO. V6 VRF unit V6 mini VRF unit Inverter split 1 2 3 4 5 6 7 8 9 10 11 12 13 14 IDU address IDU address Capacity HP of IDU Capacity HP of IDU IDU address(00) IDU capacity (kW) Indoor unit network address Indoor unit network address IDU network address (00) Actual set temperature Ts Actual set temperature Ts Current set temperature Actual T1 indoor temperature Actual T1 indoor temperature Indoor ambient temperature T1 Actual T2 indoor temperature Actual T2 indoor temperature Indoor pipe temperature T2 Actual T2A indoor temperature Actual T2A indoor temperature Actual T2B indoor temperature Actual T2B indoor temperature Temperature of FAPU, Ta Temperature of FAPU, Ta

Compressor discharge temperature Compressor discharge temperature Compressor discharge temperature Target superheat Target superheat EXV opening (actual opening/8) EXV opening (actual opening/8)

Software version No. Software version No. Software version No. Error code Error code Error code 67 V8 IDU info No. 1 2 3 4 Displayed content IDU communication address Capacity HP of IDU Actual set temperature Ts Set temperature of the unit that is operating currently, Ts (Remarks: The temperature displayed is the actual set temperature Ts) Actual T1 indoor temperature Modified indoor temperature T1_modify T2 heat exchanger intermediate temperature T2A heat exchanger liquid pipe temperature T2B heat exchanger gas pipe temperature Actual set humidity RHs Actual RH indoor humidity Actual fresh air processing unit TA air supply temperature Air discharge pipe temperature Compressor discharge temperature Target overheating EXV opening (actual opening/8) IDU Software version No. Historical error code (recent) Historical error code (sub-recent)

[] is displayed 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 68 ODU info Display V6 VRF unit V6 mini VRF unit Inverter split V8 VRF unit Description 1 2 3 4 5 6 7 ODU address ODU address ODU address (00) Unit capacity ODU address 0 to 3 Unit capacity Unit capacity Number of ODUs ODU capacity Unit: HP Number of ODUs Number of ODUs ODU Qty 1 to 4

ODU capacity demand Compressor 1 frequency Compressor 2 frequency

ODU capacity demand Compressor 1 frequency

ODU load target Operating frequency

IDU Qty settings ODU capacity demand Actual frequency of compressor 1 Actual frequency of compressor 2 Only displayed on the master unit, while the slave unit displays 0. Actual Frequency Actual Frequency 8 Operating mode Operating mode Operating mode Operating mode 0: Off 2: Cool 3: Heat 5: Hybrid cooling 6: Hybrid heating 9 10 11 12 Mode priority Priority mode

Speed of DC fan A/A1 Operating fan speed Operating speed of DC fan Fan speed 1 Fan speed Speed of DC fan B/B1 T2 average temperature

(corrected) T2 average temperature

(corrected) Indoor pipe temperature Fan speed 2 Fan speed T2 average Actual temperature 69 V6 VRF unit V6 mini VRF unit Inverter split Display 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 T2B average temperature (corrected) T2B average temperature (corrected) Indoor pipe temperature T3 condenser tube temperature T3 tube temperature Outdoor pipe temperature T3 T4 ambient temperature T4 ambient temperature Outdoor ambient temperature

T6A plate heat exchanger inlet temperature T6B plate heat exchanger outlet temperature Inverter compressor A discharge temperature Inverter compressor B discharge temperature

T5 discharge temperature

Tf1 inverter module A temperature Tf module temperature Tf2 inverter module B temperature (reserved)

TL refrigerant cooling pipe temperature

Discharge temperature

70 V8 VRF unit Description T2B average Actual temperature T3 T4 T5 T6A T6B T7C1 T7C2 T71 T72 T8 Ntc T9 TL Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature Actual temperature 28 29 30 31 32 33 34 35 36 37 Display V6 VRF unit V6 mini VRF unit Inverter split V8 VRF unit Description Discharge superheat degree Actual temperature System discharge superheat degree

Inverter compressor A current

Actual current value Current value Inverter compressor B current

Primary current Compressor 1 current Compressor 2 current Opening of electronic expansion valve A EXV Opening Expansion valve EXVA opening opening EXVB opening EXVC opening EXVD opening High pressure Low pressure Opening of electronic expansion valve B Opening of electronic expansion valve C

High pressure of system Low pressure of the system (reserved)

71 38

Online IDU Qty

Actual current V6 VRF unit: opening =

displayed value 4 V6 mini VRF unit:

opening = displayed value 8 Inverter split: opening =

displayed value 8 V8 VRF unit: opening =

displayed value 24 Opening = Displayed value 4 Pressure = Displayed value / 100 Pressure = Displayed value / 100 Display V6 VRF unit V6 mini VRF unit Inverter split V8 VRF unit Description Running IDU Qty Running IDU Qty Actual Qty 39 Number of indoor units running (in the case of virtual addresses, this is the number of units with the virtual addresses included) 40 VIP indoor unit address VIP indoor unit address 41 42 43

72

Heat exchanger status System startup status Silent settings 0: Heat exchanger off 1: C1 2: D1 3: D2 4: E1 5: F1 6: F2

[0] No special mode

[1] Oil return

[2] Defrosting

[3] Start

[4] Stop

[5] Quick inspection

[6] Self-cleaning 0 to 14 correspond to the noise level Display V6 VRF unit V6 mini VRF unit Inverter split V8 VRF unit Description Static pressure settings 0: 0Pa 1: 20Pa 2: 40Pa 3: 60Pa 4: 80Pa 5: 100Pa 6: 120Pa TES TCS DC voltage AC voltage Actual temperature Displayed value -25 Actual voltage =

Displayed value 10 Actual voltage =

Displayed value 2 ODU blockage 0 to 10 Software version Last malfunction 44 45 46 47 48 49 50 51

Program version No. Program version No. Last malfunction Last error or protection code

73 Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. This device complies with part 15 of the FCC rules and contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:

(1) This device may not cause interference.

(2) This device must accept any interference, including interference that may cause undesired operation of the device Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :

1. Lappareil ne doit pas produire de brouillage;

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 2. Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. FCC&IC This device complies with part 15 of the FCC rules and contains licence-exempt transmitter(s)/receiver(s) Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:

that comply with

(1) This device may not cause interference.

(2) This device must accept any interference, including interference that may cause undesired operation of the device Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :

1. Lappareil ne doit pas produire de brouillage;

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 2. Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCCs and ICs RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Installers must ensure that 20cm separation distance will be maintained between the device and users.Cet appareil est conforme aux limites dexposition au rayonnement RF stipules par la FCC et lIC pour une utilisation dans un environnement non contrl. Les antennes utilises pour cet metteur doivent tre installes et doivent fonctionner au moins 20 cm de distance des utilisateurs et ne doivent pas tre places prs dautres antennes ou metteurs ou fonctionner avec ceux-ci. Les installateurs doivent sassurer quune distance de 20 cm spare lappareil des utilisateurs. A V 6 5 0 4 0 0 0 0 1 7 1 1 6 1 Hereby, GD Midea Heating & Ventilating Equipment Co., Ltd., declares that this model is in compliance with the essential requirements and other relevant provisions of RE Directive 2014/53/EU. A copy of the full DoC is attached. 120*120

 

1 Users Manual pdf 5.13 MiB March 23 2026
frequency equipment class purpose
1 2026-03-23 2412 ~ 2462 DTS - Digital Transmission System Original Equipment

Application Forms

app s Applicant Information
1 Effective 2026-03-23
1 Applicant's complete, legal business name GD Midea Heating & Ventilating Equipment Co., Ltd.
1 FCC Registration Number (FRN) 0035331131
1 Physical Address Industry Avenue Penglai Road, Beijiao Residential
1 foshan, N/A
1 China
app s TCB Information
1 TCB Application Email Address T******@intertek.com
1 TCB Scope A4: UNII devices & low power transmitters using spread spectrum techniques
app s FCC ID
1 Grantee Code 2BF3F
1 Equipment Product Code KJR-120T2
app s Person at the applicant's address to receive grant or for contact
1 Name W****** L****
1 Telephone Number 13630******** Extension:
1 Fax Number 0757-********
1 E-mail l******@midea.com
app s Technical Contact
1 Firm Name Intertek Testing Services Shenzhen Ltd.Guangzhou B
1 Name R****** L****
1 Physical Address lock E, No.7-2 Guang Dong Software Science Park, C
1 Guangzhou, Gangdong, 510663
1 China
1 Telephone Number 02082********
1 E-mail R******@intertek.com
app s Non Technical Contact
1 Firm Name FCC US Agent, LLC
1 Name T******** P****
1 Physical Address 3722 llinois Avenue
1 Saint Charles, Illinois 60174
1 United States
1 Telephone Number 708-5********
1 E-mail S******@FCCUSAgent.com
app s Confidentiality (long or short term)
1 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:No
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 Is this application for software defined/cognitive radio authorization?No
1 Equipment ClassDTS - Digital Transmission System
1 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)Wired Controller
1 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?No
1 Modular Equipment TypeDoes not apply
1 Purpose / Application is forOriginal Equipment
1 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?No
1 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?No
1 Grant CommentsOutput power listed is conducted. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.
1 Is there an equipment authorization waiver associated with this application?No
1 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 Firm Name Intertek Testing Services Shenzhen LTD., Guangzhou
1 Name H****** O******
1 Telephone Number +86 2********
1 E-mail H******@intertek.com
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 15C 2412 2462 0.00605
1 2 15C 2402 2480 0.00109

 

some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details

 

  This product uses the FCC Data API but is not endorsed or certified by the FCC