all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manuals | photo | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
User Manual Rev 2 | Users Manual | 919.40 KiB | ||||
1 2 | Users Manual | March 21 2019 / September 16 2019 | ||||||
1 2 | External Photos | March 11 2019 / September 16 2019 | ||||||
1 2 | ID Label/Location Info | March 11 2019 / March 20 2019 | ||||||
1 2 | Cover Letter(s) | November 03 2019 | ||||||
1 2 | Cover Letter(s) | November 03 2019 | ||||||
1 2 | Cover Letter(s) | November 03 2019 | ||||||
1 2 | Cover Letter(s) | November 03 2019 | ||||||
1 2 | Block diagram | Block Diagram | March 11 2019 | confidential | ||||
1 2 | ID Label/Location Info | |||||||
1 2 | Rel.4 Rev2.1 faceplan 20180410 | Operational Description | March 11 2019 | confidential | ||||
1 2 | Cover Letter(s) | |||||||
1 2 | Tune up procedure | Parts List/Tune Up Info | March 11 2019 | confidential | ||||
1 2 | EHSx Rel.4 EHS8 B2.1 to EHSx Rel.3 EHS8 delta final | Operational Description | March 11 2019 | confidential | ||||
1 2 | RF Exposure Info | November 03 2019 | ||||||
1 2 | Test Report | November 03 2019 | ||||||
1 2 | Test Setup Photos | March 11 2019 / September 16 2019 | ||||||
1 2 | Test Setup Photos | March 11 2019 / September 16 2019 | ||||||
1 2 | ehs6-a hid | Operational Description | March 11 2019 | confidential | ||||
1 2 | Cover Letter(s) | November 09 2014 | ||||||
1 2 | External Photos | November 09 2014 | ||||||
1 2 | RF Exposure Info | |||||||
1 2 | Cover Letter(s) | November 09 2014 | ||||||
1 2 | Cover Letter(s) | November 09 2014 | ||||||
1 2 | Internal Photos | November 09 2014 | ||||||
1 2 | ID Label/Location Info | November 09 2014 | ||||||
1 2 | Test Report | |||||||
1 2 | Test Setup Photos | November 09 2014 |
1 2 | User Manual Rev 2 | Users Manual | 919.40 KiB |
Cinterion EHS6-A Hardware Interface Overview Version:
DocId:
02.770 EHS6-A_HIO_v02.770 M2M.GEMALTO.COM EHS6-A Hardware Interface Overview Page 2 of 40 Cinterion 2 Document Name:
Version:
Date:
DocId:
Status Cinterion EHS6-A Hardware Interface Overview 02.770 2014-08-13 EHS6-A_HIO_v02.770 Confidential / Preliminary GENERAL NOTE THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE
"PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON GEMALTO M2M PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE SUBJECT TO CHANGE AT GEMALTO M2M'S DISCRETION. GEMALTO M2M GMBH GRANTS A NONEXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHA LL NOT TRANSFER , COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, GEMALTO M2M GMBH DISC LAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW. Copyright Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Copyright 2014, Gemalto M2M GmbH, a Gemalto Company EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Trademark Notice Page 3 of 41 Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain countries. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. Contents 40 Contents 1 Introduction ........................................................................................................................... 7 1.1 Key Features at a Glance .......................................................................................... 7 1.2 EHS6-A System Overview ....................................................................................... 12 2 Interface Characteristics .................................................................................................... 13 2.1 Application Interface ................................................................................................ 13 2.1.1 USB Interface ............................................................................................ 13 2.1.2 Serial Interface ASC0 ................................................................................ 14 2.1.3 Serial Interface ASC1 ................................................................................ 14 2.1.4 UICC/SIM/USIM Interface ......................................................................... 15 2.1.5 Analog Audio Interface .............................................................................. 17 2.1.6 Digital Audio Interface ............................................................................... 17 2.1.7 GPIO Interface .......................................................................................... 17 2.1.8 I2C Interface .............................................................................................. 18 2.1.9 SPI Interface ............................................................................................. 18 2.1.10 HSIC Interface ........................................................................................ 18 2.1.11 PWM Interfaces ....................................................................................... 19 2.1.12 Pulse Counter ......................................................................................... 19 2.1.13 Status LED .............................................................................................. 19 2.1.14 Fast Shutdown ........................................................................................ 19 2.2 RF Antenna Interface ............................................................................................... 20 2.2.1 Antenna Installation ................................................................................... 21 2.3 Sample Application .................................................................................................. 22 3 Operating Characteristics .................................................................................................. 24 3.1 Operating Modes ..................................................................................................... 24 3.2 Power Supply .......................................................................................................... 24 4 Mechanical Dimensions, Mounting and Packaging ......................................................... 26 4.1 Mechanical Dimensions of EHS6-A ......................................................................... 26 5 Regulatory and Type Approval Information ...................................................................... 28 5.1 Directives and Standards ........................................................................................ 28 EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 EHS6-A Hardware Interface Overview 5.2 SAR requirements specific to portable mobiles ....................................................... 31 5.3 Reference Equipment for Type Approval ................................................................. 31 5.4 Compliance with FCC and IC Rules and Regulations ............................................. 32 6 Document Information ........................................................................................................ 34 6.1 Revision History ....................................................................................................... 34 6.2 Related Documents ................................................................................................. 34 6.3 Terms and Abbreviations ......................................................................................... 34 6.4 Safety Precaution Notes .......................................................................................... 38 7 Appendix .............................................................................................................................. 39 7.1 List of Parts and Accessories .................................................................................. 39 EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 5 of 41 Tables 111 Tables Table 1:
Table 2:
Table 3:
Table 4:
Table 5:
Table 6:
Table 7:
Table 8:
Table 9:
Table 10:
Table 11:
Table 12:
Signals of the SIM interface (SMT application interface)............................... 14 GPIO lines and possible alternative assignment............................................ 16 Return loss in the active band........................................................................ 19 Overview of operating modes ........................................................................ 23 Directives ....................................................................................................... 27 Standards of North American type approval.................................................. 27 Standards of European type approval............................................................ 27 Requirements of quality ................................................................................. 28 Standards of the Ministry of Information Industry of the Peoples Republic of China............................................................................ 28 Toxic or hazardous substances or elements with defined concentration limits............................................................................................................... 29 List of parts and accessories.......................................................................... 38 Molex sales contacts (subject to change)...................................................... 39 EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Figures Page 6 of 41 111 Figures Figure 1:
Figure 2:
Figure 3:
Figure 4:
Figure 5:
Figure 6:
Figure 7:
Figure 8:
Figure 9:
EHS6-A system overview............................................................................... 10 USB circuit ..................................................................................................... 11 Serial interface ASC0..................................................................................... 12 Serial interface ASC1..................................................................................... 13 External UICC/SIM/USIM card holder circuit ................................................. 15 Schematic diagram of EHS6-A sample application........................................ 22 EHS6-A top and bottom view....................................................................... 25 Dimensions of EHS6-A (all dimensions in mm) ............................................. 26 Reference equipment for Type Approval ....................................................... 31 EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 1.1 Key Features at a Glance 10 1 10 Introduction 1 Introduction Page 7 of 41 This document1 describes the hardware of the Cinterion EHS6-A module. It helps you quickly retrieve interface specifications, electrical and mechanical details and information on the requirements to be considered for integrating further components. 1.1 Feature General Key Features at a Glance Implementation Frequency bands GSM class Output power Power supply Operating temperature
(board temperature) Physical GSM/GPRS/EDGE: Quad band 850/900/1800/1900MHz UMTS/HSPA+: Five band 800/850/900/1900/2100MHz Small MS
+33dBm 1dB for EGSM850
+30dBm 1dB for GSM1900
+27dBm 1dB for EGPRS 850(8-PSK, 1 Tx slot)
+24dBm 1dB for EGPRS 850(8-PSK, 2 Tx slot)
+22dBm 1dB for EGPRS 850(8-PSK, 3 Tx slot)
+21dBm 1dB for EGPRS 850(8-PSK, 4 Tx slot)
+26dBm 1dB for GPRS 1900(8-PSK, 1 Tx slot)
+23dBm 1dB for EGPRS 1900(8-PSK, 2 Tx slot)
+21dBm 1dB for EGPRS 1900(8-PSK, 3 Tx slot)
+20dBm 1dB for EGPRS 1900(8-PSK, 4 Tx slot)
+33dBm 1dB forGPRS 850(GMSK, 1 Tx slot)
+30dBm 1dB for GPRS 850(GMSK,2 Tx slot)
+28dBm 1dB for GPRS 850(GMSK, 3 Tx slot)
+27dBm 1dB for GPRS 850(GMSK, 4 Tx slot)
+30dBm 1dB for GPRS 1900(GMSK, 1 Tx slot)
+27dBm 1dB for GPRS 1900(GMSK, 2 Tx slot)
+25dBm 1dB for GPRS19050(GMSK, 3 Tx slot)
+24dBm 1dB for GPRS 1900(GMSK, 4Tx slot)
+24dBm 1dB for UMTS Band 2
+24dBm 1dB for UMTS Band 5 3.3V to 4.5V Normal operation: -30C to +85C Extended operation: -40C to +90C Dimensions: 27.6mm x 25.4mm x 2.2mm Weight: approx. 3.5g 1 . The document is effective only if listed in the appropriate Release Notes as part of th e technical documentation delivered with your Gemalto M2M product. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 8 of 41 RoHS All hardware components fully compliant with EU RoHS Directive HSPA features 3GPP Release 6, 7 DL 7.2Mbps, UL 5.7Mbps HSDPA Cat.8 / HSUPA Cat.6 data rates Compressed mode (CM) supported according to 3GPP TS25.212 UMTS features 3GPP Release 4 PS data rate 384 kbps DL / 384 kbps UL CS data rate 64 kbps DL / 64 kbps UL Implementation Feature GSM/GPRS/EGPRS features Data transfer Coding Scheme 1 4 EGPRS:
Full PBCCH support GPRS:
Multislot Class 12 Mobile Station Class B Multislot Class 12 Mobile Station Class B CSD:
V.110, RLP, non-transparent 9.6kbps USSD EDGE E2 power class for 8 PSK Downlink coding schemes CS 1-4, MCS 1-9 Uplink coding schemes CS 1-4, MCS 1-9 SRB loopback and test mode B 8-bit, 11-bit RACH PBCCH support 1 phase/2 phase access procedures Link adaptation and IR NACC, extended UL TBF SMS Audio Software Point-to-point MT and MO Cell broadcast Text and PDU mode Storage: SIM card plus SMS locations in mobile equipment Speech codecs:
Half rate HR (ETS 06.20) Full rate FR (ETS 06.10) Enhanced full rate EFR (ETS 06.50/06.60/06.80) Adaptive Multi Rate AMR 7 different ringing tones/melodies EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 1.1 Key Features at a Glance 10 AT commands Hayes 3GPP TS 27.007, TS 27.005, Gemalto M2M AT commands for RIL compatibility Page 9 of 41 Java Open Platform Java profile IMP-NG & CLDC 1.1 HI Java Open Platform with Secure data transmission via HTTPS/SSL Multi-threading programming and multi-application execution Major benefits: seamless integration into Java applications, ease of programming, no need for application microcontroller, extremely cost-
efficient hardware and software design ideal platform for industrial GSM applications. The memory space available for Java programs is around 8 MB in the flash file system and around 6MB RAM. Application code and data share the space in the flash file system and in RAM. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 1.1 Key Features at a Glance 10 Feature Microsoft compatibility RIL for Pocket PC and Smartphone Implementation Page 10 of 41 SIM Application Toolkit Firmware update Interfaces Module interface SAT Release 99 Generic update from host application over ASC0 or USB modem. Surface mount device with solderable connection pads (SMT application interface). Land grid array (LGA) technology ensures high solder joint reliability and provides the possibility to use an optional module mounting socket. For more information on how to integrate SMT modules see also [3]. This application note comprises chapters on module mounting and application layout issues as well as on additional SMT application development equipment. USB 2.0 High Speed (480Mbit/s) device interface, Full Speed (12Mbit/s) compliant ASC0 (shared with GPIO lines):
8-wire modem interface with status and control lines, unbalanced, asynchronous Adjustable baud rates: 1,200bps to 921,600bps Autobauding: 1,200bps to 230,400bps Supports RTS0/CTS0 hardware flow control. Multiplex ability according to GSM 07.10 Multiplexer Protocol. ASC1
(shared with GPIO lines):
4-wire, unbalanced asynchronous interface Adjustable baud rates: 1,200bps to 921,60bps Autobauding: 1,200bps to 230,400bps Supports RTS1/CTS1 hardware flow control 1 analog interface (with microphone feeding) 1 digital interface (PCM), shared with GPIO lines Supported SIM/USIM cards: 3V, 1.8V 14 GPIO lines shared with ASC0 lines, LED signalling, PWM functionality, fast shutdown and pulse counter 4 GPIO lines shared with PCM interface 4 GPIO lines shared with ASC1, SPI and HSIC interfaces Supports I2C serial interface High-Speed Inter-Chip (HSIC) interface for USB chip-to-chip interconnect including Link Power Management (LPM) lines shared with GPIO lines Serial peripheral interface, shared with GPIO lines 50 USB 2 serial interfaces Audio UICC interface GPIO interface I2C interface HSIC interface SPI interface Antenna interface pads Power on/off, Reset EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 1.1 Key Features at a Glance 10 Power on/off Page 11 of 41 Reset Feature Special features Real time clock Phonebook TTY/CTM support Evaluation kit Evaluation module DSB75 Switch-on by hardware signal AUTO_ON and ON Switch-off by AT command Switch off by hardware signal FST_SHDN instead of AT command Automatic switch-off in case of critical temperature and voltage conditions Orderly shutdown and reset by AT command Emergency reset by hardware signal EMERG_RST Implementation Timer functions via AT commands SIM and phone Integrated CTM modem EHS6-A module soldered onto a dedicated PCB that can be connected to an adapter in order to be mounted onto the DSB75. DSB75 Development Support Board designed to test and type approve Gemalto M2M modules and provide a sample configuration for application engineering. A special adapter is required to connect the EHS6-A evaluation module to the DSB75. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 12 of 41 1.2 EHS6-A System Overview 10 1.2 EHS6-A System Overview
EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 2 Interface Characteristics 22 2 Interface Characteristics Page 13 of 41 EHS6-A is equipped with an SMT application interface that connects to the external application. The SMT application interface incorporates the various application interfaces as well as the RF antenna interface. 2.1 Application Interface USB Interface 2.1.1 EHS6-A supports a USB 2.0 High Speed (480Mbit/s) device interface that is Full Speed
(12Mbit/s) compliant. The USB interface is primarily intended for use as command and data interface and for downloading firmware. The external application is responsible for supplying the VUSB_IN line. This line is used for cable detection only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because EHS6-A is designed as a self-powered device compliant with the Universal Serial Bus Specification Revision 2.01. Module VREG (3V075) lin. reg. SMT USB part 1) VBUS DP DN Detection only RS RS Host wakeup BATT+
GND VUSB_IN USB_DP 2) USB_DN 2) RING0 1) All serial (including RS) and pull-up resistors for data lines are implemented. 2) If the USB interface is operated in High Speed mode (480MHz), it is recommended to take special care routing the data lines USB_DP and USB_DN. Application layout should in this case implement a differential impedance of 90 ohms for proper signal integrity. Figure 2: USB circuit To properly connect the module's USB interface to the external application, a USB 2.0 compatible connector and cable or hardware design is required. Furthermore, the USB modem driver distributed with EHS6-A needs to be installed. 1 . The specification is ready for download on http://www.usb.org/developers/docs/
EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 2.1 Application Interface 22 2.1.2 EHS6-A offers an 8-wire unbalanced, asynchronous modem interface ASC0 conforming to ITU-T V.24 protocol DCE signalling. The electrical characteristics do not comply with ITU-T V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state). Serial Interface ASC0 Page 14 of 41 EHS6-A is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: Port TXD
@ application sends data to the modules TXD0 signal line Port RXD @ application receives data from the modules RXD0 signal line Figure 3: Serial interface ASC0 Features:
Includes the data lines TXD0 and RXD0, the status lines RTS0 and CTS0 and, in addition, the modem control lines DTR0, DSR0, DCD0 and RING0. ASC0 is designed for controlling GSM/UMTS voice calls, transferring data and for controlling the module with AT commands. Full multiplexing capability allows the interface to be partitioned into virtual channels. The RING0 signal serves to indicate incoming calls and other types of URCs (Unsolicited Result Code). It can also be used to send p ulses to the host application, for example to wake up the application from power saving state. Configured for 8 data bits, no parity and 1 stop bit. ASC0 can be operated at fixed bit rates from 1,200bps up to 921,600bps. Autobauding supports bit rates from 1,200bps up to 230,400bps. Supports RTS0/CTS0 hardware flow control. The hardware hand shake line RTS0 has an internal pull down resistor causing a low level signal, if t he line is n ot used and open. Although hardware flow control is recommended, this allows communication by using only RXD and TXD lines. Serial Interface ASC1 Wake up from SLEEP mode by RTS0 activation (high to low transition). 2.1.3 Four EHS6-A GPIO lines can be configured as ASC1 interface signals to provide a 4-wire unbalanced, asynchronous modem interface ASC1 conforming to ITU-T V.24 protocol DCE signalling. The electrical characteristics do not comply with ITU-T V.28. The significant levels are 0V (for low data bit or active state) and 1.8V (for high data bit or inactive state). EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 2.1 Application Interface 22 EHS6-A is designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: Port TXD
@ application sends data to modules TXD1 signal line Port RXD @ application receives data from the modules RXD1 signal line Page 15 of 41 Figure 4: Serial interface ASC1 Includes only the data lines TXD1 and RXD1 plus RTS1 and CTS1 for hardware han dshake. Features On ASC1 no RING line is available. Configured for 8 data bits, no parity and 1 or 2 stop bits. ASC1 can be operated at fixed bit rates from 1,200 bps to 921,600 bps. Autobauding supports bit rates from 1,200bps up to 230,400bps. Supports RTS1/CTS1 hardware flow. The hardware hand shake line RTS0 has an internal pull down resistor causing a low level signal, if the line is not used and open. Although hardware flow control is recommended, this allows communication by using only RXD and TXD lines. UICC/SIM/USIM Interface 2.1.4 EHS6-A has an integrated UICC/SIM/USIM interface compatible with the 3GPP 31.102 and ETSI 102 221. This is wired to the host interface in order to be connected to an external SIM card holder. Five pads on the SMT application interface are reserved for the SIM interface. The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards. The CCIN signal serves to detect whether a tray (with SIM card) is present in the card holder. Using the CCIN signal is mandatory for compliance with the GSM 11.11 recommendation if the mechanical design of the host application allows the user to remove the SIM card during operation. To take advantage of this feature, an appropriate SIM card detect switch is required on the card holder. For example, this is true for the model supplied by Molex, which has been tested to operate with EHS6-A and is part of the Gemalto M2M reference equipment submitted for type approval. See Section 7.1 for Molex ordering numbers. Table 1: Signals of the SIM interface (SMT application interface) Signal GND CCCLK Chipcard clock CCVCC SIM supply voltage. Description Separate ground connection for SIM card to improve EMC. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Page 16 of 41 Cinterion EHS6-A Hardware Interface Overview 2.1 Application Interface 22 CCIO CCRST Chipcard reset CCIN Serial data line, input and output. Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is removed during operation the SIM interface is shut down immediately to prevent destruction of the SIM. The CCIN signal is by default low and will change to highl evel if a SIM card is inserted. The CCIN signal is mandatory for applications that allow the user to remove the SIM card during operation. The CCIN signal is solely intended for use with a SIM card. It must not be used for any other purposes. Failure to comply with this requirement may invalidate the type approval of EHS6-A. Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after removing the SIM card during operation. Also, no guarantee can be given for properly initializing any SIM card that the user inserts after having removed the SIM card during operation. In this case, the application must restart EHS6-A. The figure below shows a circuit to connect an external SIM card holder. V180 CCIN CCVCC CCRST CCIO CCCLK SIM 220 nF 1 nF Figure 5: External UICC/SIM/USIM card holder circuit The total cable length between the SMT application interface pads on EHS6-A and the pads of the external SIM card holder must not exceed 100mm in order to meet the specifications of 3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance. To avoid possible cross-talk from the CCCLK signal to the CCIO signal be careful that both lines are not placed closely next to each other. A useful approach is using a GND line to shield the CCIO line from the CCCLK line. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 2.1 Application Interface 22 2.1.5 EHS6-A has an analog audio interface with a balanced analog microphone input and a balanced analog earpiece output. A supply voltage and an analog ground connection are provided at dedicated pads. Analog Audio Interface Page 17 of 41 Digital Audio Interface 2.1.6 EHS6-A digital audio interface (DAI) can be used to connect audio devices capable of pulse code modulation (PCM). 2.1.7 GPIO Interface EHS6-A offers a GPIO interface with 22 GPIO lines. The GPIO lines are shared with other interfaces or functions: Fast shutdown (see Section 2.1.14), status LED (see Section 2.1.13), the PWM functionality (see Section 2.1.11), an pulse counter (see Section 2.1.12), ASC0 (see Section 2.1.2), ASC1 (see Section 2.1.3), an SPI interface (see Section 2.1.9), an HSIC interface (see Section 2.1.10) and a PCM interface (see Section 2.1.11) The following table shows the configuration variants for the GPIO pads. All variants are mutually exclusive, i.e. a pad configured for instance as Status LED is locked for alternative usage. Table 2: GPIO lines and possible alternative assignment GPIO ASC0 ASC1 SPI PWM Pulse HSIC PCM Fast Shutdown Status LED Counter PWM2 PWM1 Status LED GPIO1 GPIO2 GPIO3 GPIO4 FST_SHDN GPIO5 GPIO6 GPIO7 GPIO8 GPIO11 GPIO12 GPIO13 GPIO14 GPIO15 GPIO16 DTR0 DCD0 DSR0 COUNTER SPI_CLK AP_WAKEUP RXD1 MOSI EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 RTS1 CTS1 SPI_CS SUSPEND TXD1 MISO Page 18 of 41 CP_WAKEUP HOST_ACTIVE Cinterion EHS6-A Hardware Interface Overview 2.1 Application Interface 22 GPIO17 GPIO18 GPIO19 GPIO20 GPIO21 GPIO22 GPIO23 GPIO24 After startup, the above mentioned alternative GPIO line assignments can be configured using AT commands (see [1]). The configuration is non-volatile and available after module restart. 2.1.8 I2C is a serial, 8-bit oriented data transfer bus for bit rates up to 400kbps in Fast mode. It consists of two lines, the serial data line I2CDAT and the serial clock line I2CCLK. The module acts as a single master device, e.g. the clock I2CCLK is driven by the module. I2CDAT is a bi-
directional line. Each device connected to the bus is software addressable by a unique 7-bit address, and simple master/slave relationships exist at all times. The module operates as mastertransmitter or as master-receiver. The customer application transmits or receives data only on request of the module. I2C Interface RING0 RXDDAI TXDDAI TFSDAI SCLK The I2C interface can be powered via the V180 line of EHS6-A. If connected to the V180 line, the I2C interface will properly shut down when the module enters the Power Down mode. Note: Good care should be taken when creating the PCB layout of the host application: The traces of I2CCLK and I2CDAT should be equal in length and as short as possible. SPI Interface 2.1.9 Four EHS6-A GPIO interface lines can be configured as Serial Peripheral Interface (SPI). The SPI is a synchronous serial interface for control and data transfer between EHS6-A and the external application. Only one application can be connected to the SPI and the interface supports only master mode. The transmission rates are up to 6.5Mbit/s. The SPI interface comprises the two data lines MOSI and MISO, the clock line SPI_CLK a well as the chip select line SPI_CS. 2.1.10 HSIC Interface The (USB) High Speed Inter Chip Interface can be used between the module and an external application processor and is compliant to the High Speed USB 2.0 interface with 480Mbit/s. The maximum distance between module processor and external application processor should not exceed 100mm. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 2.1 Application Interface 22 The HSIC interface comprises 6 lines:
Two signal lines (strobe - HSIC_STRB - and data - HSIC_DATA) are used in a source synchronous serial interface with a 240MHz clock to provide a 480Mbps USB interface. The HSIC_STRB and HSIC_DATA lines are high-speed signals and should be routed as 50 impedance traces. The trace length of these signals should be balanced to minimize timing skew and no longer as 100mm. Page 19 of 41 Four signal lines for Link Power Management (LPM). For further power reduction, the USB HSIC interface supports LPM according to the USB 2.0 standard. The LPM defines power management states and mechanisms to affect state changes that are used b y the AP_WAKEUP and CP_WAKEUP signal lines to efficiently manage bus and system power. To take advantage of the LPM feature, two further signals are needed to support power management state transitions - the SUSPEND and HOST_ACTIVE signals. 2.1.11 PWM Interfaces The GPIO6 and GPIO7 interface lines can be configured as Pulse Width Modulation interface lines PWM1 and PWM2. The PWM interface lines can be used, for example, to connect buzzers. The PWM1 line is shared with GPIO7 and the PWM2 line is shared with GPIO6 (for GPIOs see Section 2.1.7). GPIO and PWM functionality are mutually exclusive. 2.1.12 Pulse Counter The GPIO8 line can be configured as pulse counter line COUNTER. The pulse counter interface can be used, for example, as a clock (for GPIOs see Section 2.1.7). 2.1.13 Status LED The GPIO5 interface line can be configured to drive a status LED that indicates different operating modes of the module (for GPIOs see Section 2.1.7). GPIO and LED functionality are mutually exclusive. 2.1.14 Fast Shutdown The GPIO4 interface line can be configured as fast shutdown signal line FST_SHDN. The configured FST_SHDN line is an active low control signal and must be applied for at least 10 milliseconds. If unused this line can be left open because of a configured internal pull-up resistor. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 2.2 RF Antenna Interface 22 Page 20 of 41 RF Antenna Interface 2.2 The RF interface has an impedance of 50. EHS6-A is capable of sustaining a total mismatch at the antenna line without any damage, even when transmitting at maximum RF power. The external antenna must be matched properly to achieve best performance regarding radiated power, modulation accuracy and harmonic suppression. Antenna matching networks are not included on the EHS6-A module and should be placed in the host application if the antenna does not have an impedance of 50. Regarding the return loss EHS6-A provides the following values in the active band:
Table 3: Return loss in the active band State of module Return loss of module Receive Transmit Recommended return loss of application
> 12dB
> 12dB
> 8dB not applicable EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 2.2 RF Antenna Interface 22 Page 21 of 41 Antenna Installation 2.2.1 The antenna is connected by soldering the antenna pad (ANT_GSM, i.e., pad #59) and its neighboring ground pads (GND, i.e., pads #58 and #60) directly to the applications PCB. The antenna pad is the antenna reference point (ARP) for EHS6-A. All RFd ata specified throughout this document is related to the ARP. The distance between the antenna ANT_GSM pad (#59) and its neighboring GND pads (#58,
#60) has been optimized for best possible impedance. On the application PCB, special attention should be paid to these 3 pads, in order to prevent mismatch. The wiring of the antenna connection line, starting from the antenna pad to the application antenna should result in a 50 line impedance. Line width and distance to the GND plane needs to be optimized with regard to the PCBs layer stack. To prevent receiver desensitization due to interferences generated by fast transients like high speed clocks on the application PCB, it is recommended to realize the antenna connection line using embedded Stripline rather than Micro-Stripline technology. For type approval purposes, the use of a 50 coaxial antenna connector (U.FL-R-SMT) might be necessary. In this case the U.FL-R-SMT connector should be placed as close as possible to EHS6-As antenna pad. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 2.3 Sample Application 22 Page 22 of 41 Sample Application 2.3 Figure 6 shows a typical example of how to integrate a EHS6-A module with an application. Usage of the various host interfaces depends on the desired features of the application. The analog audio interface demonstrates the balanced connection of microphone and earpiece. This solution is particularly well suited for internal transducers. Because of the very low power consumption design, current flowing from any other source into the module circuit must be avoided, for example reverse current from high state external control lines. Therefore, the controlling application must be designed to prevent reverse current flow. Otherwise there is the risk of undefined states of the module during startup and shutdown or even of damaging the module. Because of the high RF field density inside the module, it cannot be guaranteed that no self interference might occur, depending on frequency and the applications grounding concept. The potential interferers may be minimized by placing small capacitors (47pF) at suspected lines (e.g. RXD0, RXT0, VDDLP, and ON). While developing SMT applications it is strongly recommended to provide test points for certain signals, i.e., lines to and from the module - for debug and/or test purposes. The SMT application should allow for an easy access to these signals. For details on how to implement test points see [3]. The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for an individual application is very much determined by the overall layout and, especially, the position of components. For example, mounting the internal acoustic transducers directly on the PCB eliminates the need to use the ferrite beads shown in the sample schematic. Note: EHS6-A is not intended for use with cables longer than 3m. Disclaimer No warranty, either stated or implied, is provided on the sample schematic diagram shown in Figure 6 and the information detailed in this section. As functionality and compliance with national regulations depend to a great amount on the used electronic components and the individual application layout manufacturers are required to ensure adequate design and operating safeguards for their products using EHS6-A modules. 2.3 Sample Application 22 EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 23 of 41 Figure 6: Schematic diagram of EHS6-A sample application 3 Operating Characteristics 24
EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Function GSM /
GPRS / UMTS /
HSPA SLEEP GSM /
GPRS / UMTS /
HSPA IDLE GSM TALK/
GSM DATA GPRS DATA EGPRS DATA UMTS TALK/
UMTS DATA HSPA DATA Cinterion EHS6-A Hardware Interface Overview Page 24 of 41 3 Operating Characteristics Operating Modes 3.1 The table below briefly summarizes the various operating modes referred to throughout the document. Table 4: Overview of operating modes Mode Normal operation Power saving set automatically when no call is in progress and the USB connection is suspended by host or not present and no active communication via ASC0. Power saving disabled or an USB connection not suspended, but no call in progress. Connection between two subscribers is in progress. Power consumption depends on the GSM network coverage and several connection settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences and antenna connection). The following applies when power is to be measured in TALK_GSM mode: DTX off, FR and no frequency hopping. GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings). EGPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and EGPRS configuration (e.g. used multislot settings). UMTS data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. HSPA data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. Power Down Airplane mode Normal shutdown after sending the power down command. Only a voltage regulator is active for powering the RTC. Software is not active. Interfaces are not accessible. Operating voltage remains applied. Airplane mode shuts down the radio part of the module, causes the module to log off from the GSM/GPRS network and disables all AT commands whose execution requires a radio connection. Airplane mode can be controlled by AT command (see [1]). 3.2 Power Supply 24 Power Supply 3.2 EHS6-A needs to be connected to a power supply at the SMT application interface - 2 lines BATT+, and GND. There are two separate voltage domains for BATT+:
BATT+BB with a line for the general power management. BATT+RF with a line for the GSM power amplifier supply. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 25 of 41 Please note that throughout the document BATT+ refers to both voltage domains and power supply lines - BATT+BB and BATT+RF. The power supply of EHS6-A has to be a single voltage source at BATT+BB and BATT+RF. It must be able to provide the peak current during the uplink transmission. All the key functions for supplying power to the device are handled by the power management section of the analog controller. This IC provides the following features:
Stabilizes the supply voltages for the baseband using low drop linear voltage regulators and a DC-DC step down switching regulator. Switches the module's power voltages for the power-up and -down procedures. SIM switch to provide SIM power supply. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 4 Mechanical Dimensions, Mounting and Packaging 26 Page 26 of 41 4 Mechanical Dimensions, Mounting and Packaging Mechanical Dimensions of EHS6-A 4.1 Figure 7 shows the top and bottom view of EHS6-A and provides an overview of the board's mechanical dimensions. For further details see Figure 8. Product label Top view Bottom view 4.1 Mechanical Dimensions of EHS6-A 26 Figure 7: EHS6-A top and bottom view EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 27 of 41 Figure 8: Dimensions of EHS6-A (all dimensions in mm) 5 Regulatory and Type Approval Information 32
EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 28 of 41 5 Regulatory and Type Approval Information Directives and Standards 5.1 EHS6-A is designed to comply with the directives and standards listed below. It is the responsibility of the application manufacturer to ensure compliance of the final product with all provisions of the applicable directives and standards as well as with the technical specifications provided in the "EHS6-A Hardware Interface Description".1 Table 5: Directives 1999/05/EC 2002/95/EC (RoHS 1) 2011/65/EC (RoHS 2) Directive of the European Parliament and of the council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (in short referred to as R&TTE Directive 1999/5/EC). The product is labeled with the CE conformity mark Directive of the European Parliament and of the Council of 27 January 2003 (and revised on 8 June 2011) on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) Table 6: Standards of North American type approval CFR Title 47 OET Bulletin 65 (Edition 97-01) UL 60 950-1 NAPRD.03 V5.15 Code of Federal Regulations, Part 22 and Part 24 (Telecommunications, PCS); US Equipment Authorization FCC Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Product Safety Certification (Safety requirements) Overview of PCS Type certification review board Mobile Equipment Type Certification and IMEI control PCS Type Certification Review board (PTCRB) Canadian Standard RSS132 (Issue2) RSS133 (Issue5) Table 7: Standards of European type approval 3GPP TS 51.010-1 Digital cellular telecommunications system (Release 7); Mobile Station
(MS) conformance specification;
ETSI EN 301 511 V9.0.2 Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essential requirements under article 3.2 of the R&TTE directive (1999/5/EC) Global Certification Forum - Certification Criteria GCF-CC V3.49 ETSI EN 301 489-01 V1.9.2 Electromagnetic Compatibility and Radio spectrum Matters (ERM);
Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common Technical Requirements 1 . Manufacturers of applications which can be used in the US shall ensure that their applications have a PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module. EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 5.1 Directives and Standards 32 Page 29 of 41 Table 7: Standards of European type approval ETSI EN 301 489-07 V1.3.1 ETSI EN 301 489-24 V1.5.1 ETSI EN 301 908-01 V5.2.1 ETSI EN 301 908-02 V5.2.1 EN 62311:2008 Electromagnetic Compatibility and Radio spectrum Matters (ERM);
Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems
(GSM and DCS) Electromagnetic Compatibility and Radio spectrum Matters (ERM);
Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread
(UTRA) for Mobile and portable (UE) radio and ancillary equipment Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 1: Harmonized EN for IMT-2000, introduction and common requirements of article 3.2 of the R&TTE Directive Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 2: Harmonized EN for IMT-2000, CDMA Direct Spread (UTRA FDD) (UE) covering essential requirements of article 3.2 of the R&TTE Directive Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) Safety of information technology equipment IEC/EN 60950-1:2006/
A1:2010+A12:2011 IEC 60950-1:2005/
A1:2009
(second edition) Table 8: Requirements of quality IEC 60068 DIN EN 60529 Table 9: Standards of the Ministry of Information Industry of the Peoples Republic of China SJ/T 11363-2006 Environmental testing IP codes SJ/T 11364-2006 Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products (2006-06). Marking for Control of Pollution Caused by Electronic Information Products (2006-06). According to the Chinese Administration on the Control of Pollution caused by Electronic Information Products
(ACPEIP) the EPUP, i.e., Environmental Protection Use Period, of this product is 20 years as per the symbol shown here, unless otherwise marked. The EPUP is valid only as long as the product is operated within the operating limits described in the Gemalto M2M Hardware Interface Description. Please see Table 10 for an overview of toxic or hazardous substances or elements that might be contained in product parts in concentrations above the limits defined by SJ/T 11363-2006. 5.1 Directives and Standards 32 EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Table 10: Toxic or hazardous substances or elements with defined concentration limits Page 30 of 41
EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 5.2 SAR requirements specific to portable mobiles 32 Page 31 of 41 SAR requirements specific to portable mobiles 5.2 Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of portable EHS6-A based applications to be evaluated and approved for compliance with national and/or international regulations. Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use. For European and USmarkets the relevant directives are mentioned below. It is the responsibility of the manufacturer of the final product to verify whether or not further standards, recommendations or directives are in force outside these areas. Products intended for sale on US markets ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to Electromagnetic Fields (EMFs) from Mobile Telecommunication Equipment (MTE) in the frequency range 30MHz - 6GHz Products intended for sale on European markets EN 50360 Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields
(300MHz - 3GHz) Please note that SAR requirements are specific only for portable devices and not for mobile devices as defined below:
Portable device:
A portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Mobile device:
A mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. In this context, the term ''fixed location'' means that the device is physically secured at one location and is not able to be easily moved to another location. 5.3 Reference Equipment for Type Approval 32 Reference Equipment for Type Approval 5.3 The Gemalto M2M reference setup submitted to type approve EHS6-A (including a special approval adapter for the DSB75) is shown in the following figure1:
EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 32 of 41 1. For RF performance tests a mini-SMT/U.FL to SMA adapter with attached 6dB coaxial attenuator is chosen to connect the evaluation module directly to the GSM/UMTS test equipment instead of employing the SMA antenna connectors on the EHS6-A-DSB75 adapter as shown in Figure 9. The following products are recommended:
Hirose SMA-Jack/U.FL-Plug conversion adapter HRMJ-U.FLP(40)
(for details see http://www.hirose-connectors.com/ or http://www.farnell.com/
Aeroflex Weinschel Fixed Coaxial Attenuator Model 3T/4T
(for details see http://www.aeroflex.com/ams/weinschel/pdfiles/wmod3&4T.pdf) 5.4 Compliance with FCC and IC Rules and Regulations 32 Compliance with FCC and IC Rules and Regulations 5.4 The Equipment Authorization Certification for the Gemalto M2M reference application described in Section 5.3 will be registered under the following identifiers:
EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 33 of 41 FCC Identifier: QIPEHS6-A Industry Canada Certification Number: 7830A-EHS6A Granted to Gemalto M2M GmbH Manufacturers of mobile or fixed devices incorporating EHS6-A modules are authorized to use the FCC Grants and Industry Canada Certificates of the EHS6-A modules for their own final products according to the conditions referenced in these documents. In this case, an FCC/ IC label of the module shall be visible from the outside, or the host device shall bear a second label stating "Contains FCC ID QIPEHS6-A", and accordingly Contains IC 7830A-EHS6A. The integration is limited to fixed or mobile categorised host devices, where a separation distance between the antenna and any person of min. 20cm can be assured during normal operating conditions. For mobile and fixed operation configurations the antenna gain, including cable loss, must not exceed the limits 2.15 dBi (850 MHz) and 2.15 dBi (1900 MHz). IMPORTANT:
Manufacturers of portable applications incorporating EHS6-A modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for portable mobiles (see Section 5.2 for detail). Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver Increase the separation between the equipment and receiver. is connected. Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. If Canadian approval is requested for devices incorporating EHS6-A modules the above note will have to be provided in the English and French language in the final user documentation. Manufacturers/OEM Integrators must ensure that the final user documentation does not contain any information on how to install or remove the module from the final product. 6 Document Information 37 EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 34 of 41 6 6.1 Document Information Revision History Related Documents What is new Initial document setup. New document: "Cinterion EHS6-A Hardware Interface Overview" Version 02.770 Chapter
--
6.2
[1] EHS6-A AT Command Set
[2] EHS6-A Release Note
[3] Application Note 48: SMT Module Integration
[4] Application Note 40: Thermal Solutions
[5] Universal Serial Bus Specification Revision 2.0, April 27, 2000 Terms and Abbreviations 6.3 Abbreviation Description ADC AGC ANSI ARFCN ARP ASC0/ASC1 Analog-to-digital converter Automatic Gain Control American National Standards Institute Absolute Radio Frequency Channel Number Antenna Reference Point Asynchronous Controller. Abbreviations used for first and second serial interface of EHS6-A Thermistor Constant Bit Error Rate Base Transceiver Station Cell Broadcast Message Conformit Europene (European Conformity) Challenge Handshake Authentication Protocol Central Processing Unit Coding Scheme Circuit Switched Data Clear to Send B BER BTS CB or CBM CE CHAP CPU CS CSD CTS EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview 6.3 Terms and Abbreviations 37 Page 35 of 41 Abbreviation Description DAC DAI dBm0 DCE DCS 1800 DRX DSB DSP DSR DTE Digital-to-Analog Converter Digital Audio Interface Digital level, 3.14dBm0 corresponds to full scale, see ITU G.711, A-law Data Communication Equipment (typically modems, e.g. Gemalto M2M module) Digital Cellular System, also referred to as PCN Discontinuous Reception Development Support Box Digital Signal Processor Data Set Ready Data Terminal Equipment (typically computer, terminal, printer or, for example, GSM application) Data Terminal Ready Discontinuous Transmission Enhanced Full Rate Enhanced GSM Equivalent Isotropic Radiated Power Electromagnetic Compatibility Effective Radiated Power Electrostatic Discharge European Telecommunication Standard Federal Communications Commission (U.S.) Frequency Division Multiple Access Full Rate Gaussian Minimum Shift Keying General Purpose Input/Output General Packet Radio Service Global Standard for Mobile Communications High Impedance Half Rate Input/Output Integrated Circuit International Mobile Equipment Identity International Standards Organization EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 DTR DTX EFR EGSM EIRP EMC ERP ESD ETS FCC FDMA FR GMSK GPIO GPRS GSM HiZ HR I/O IC IMEI ISO Page 36 of 41 Cinterion EHS6-A Hardware Interface Overview 6.3 Terms and Abbreviations 37 ITU kbps LED Li-Ion/Li+
Li battery International Telecommunications Union kbits per second Light Emitting Diode Lithium-Ion Rechargeable Lithium Ion or Lithium Polymer battery Abbreviation Description LPM Mbps MMI MO MS MSISDN MT NTC OEM PA PAP PBCCH PCB PCL PCM PCN PCS PDU PLL PPP PSK PSU PWM R&TTE RAM RF RLS RMS Link Power Management Mbits per second Man Machine Interface Mobile Originated Mobile Station (GSM module), also referred to as TE Mobile Station International ISDN number Mobile Terminated Negative Temperature Coefficient Original Equipment Manufacturer Power Amplifier Password Authentication Protocol Packet Switched Broadcast Control Channel Printed Circuit Board Power Control Level Pulse Code Modulation Personal Communications Network, also referred to as DCS 1800 Personal Communication System, also referred to as GSM 1900 Protocol Data Unit Phase Locked Loop Point-to-point protocol Phase Shift Keying Power Supply Unit Pulse Width Modulation Radio and Telecommunication Terminal Equipment Random Access Memory Radio Frequency Radio Link Stability Root Mean Square (value) EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Page 37 of 41 Cinterion EHS6-A Hardware Interface Overview 6.3 Terms and Abbreviations 37 RoHS Restriction of the use of certain hazardous substances in electrical and electronic equipment. Read-only Memory Real Time Clock Request to Send Receive Direction Specific Absorption Rate Surface Accoustic Wave Safety Extra Low Voltage Subscriber Identification Module ROM RTC RTS Rx SAR SAW SELV SIM Abbreviation Description SMD SMS SMT SPI SRAM TA TDMA TE TLS Tx UART URC USSD VSWR Surface Mount Device Short Message Service Surface Mount Technology Serial Peripheral Interface Static Random Access Memory Terminal adapter (e.g. GSM module) Time Division Multiple Access Terminal Equipment, also referred to as DTE Transport Layer Security Transmit Direction Universal asynchronous receiver-transmitter Unsolicited Result Code Unstructured Supplementary Service Data Voltage Standing Wave Ratio EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 38 of 41 6.4 Safety Precaution Notes 37 Safety Precaution Notes 6.4 The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating EHS6-A. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Gemalto M2M assumes no liability for customers failure to comply with these precautions. When in a hospital or other health care facility, observe the restrictions on the use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their hand-held mobile away from the pacemaker, while it is on. Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both. Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard. Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special regulations and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger. Road safety comes first! Do not use a hand-held cellular terminal or mobile when driving a vehicle, unless it is securely mounted in a holder for speakerphone operation. Before making a call with a hand-held terminal or mobile, park the vehicle. Speakerphones must be installed by qualified personnel. Faulty installation or operation can constitute a safety hazard. IMPORTANT!
Cellular terminals or mobiles operate using radio signals and cellular networks. Because of this, connection cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls. Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength. Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate those features before you can make an emergency call. Some networks require that a valid SIM card be properly inserted in the cellular terminal or mobile.
EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 39 of 41 7 Appendix 39 7 Appendix List of Parts and Accessories 7.1 Table 11: List of parts and accessories Description EHS6-A Supplier Gemalto M2M Standard module Ordering information Gemalto M2M IMEI:
Packaging unit (ordering) number: L30960-N2960-A300 Module label number: S30960-S2960-A300-1 Customer IMEI mode:
Packaging unit (ordering) number: L30960-N2965-A300 Module label number: S30960-S2965-A300-1 DSB75 Evaluation Kit for Multi-Adapter R1 mounting EHS6-A evaluation modules onto DSB75 for Approval mounting EHS6-A evaluation modules onto DSB75 Evaluation Module adapter Gemalto M2M Ordering number: L36880-N8811-A100 Gemalto M2M Ordering number: L30960-N0010-A100 Gemalto M2M Ordering number: L30960-N2301-A100 Gemalto M2M Ordering number: L30960-N2961-A300 (EHS6-A) Votronic Handset Votronic /
Gemalto M2M SIM card holder incl. push button ejector and slide-in tray 7.1 List of Parts and Accessories 39 Molex Gemalto M2M ordering number: L36880-N8301-A107 Votronic ordering number: HH-SI-30.3/V1.1/0 Votronic Entwicklungs- und Produktionsgesellschaft fr elektronische Gerte mbH Saarbrcker Str. 8 66386 St. Ingbert Germany Phone: +49-(0)6 89 4 / 92 55-0 Fax: +49-(0)6 89 4 / 92 55-88 Email: contact@votronic.com Ordering numbers: 91228 91236 Sales contacts are listed in Table 12. Table 12: Molex sales contacts (subject to change) EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 Cinterion EHS6-A Hardware Interface Overview Page 40 of 41 Molex For further information please click:
http://www.molex.com Molex China Distributors Beijing, Room 1311, Tower B, COFCO Plaza No. 8, Jian Guo Men Nei Street, 100005 Beijing P.R. China Phone: +86-10-6526-9628 Fax: +86-10-6526-9730 Molex Deutschland GmbH Otto-Hahn-Str. 1b 69190 Walldorf Germany Phone: +49-6227-3091-0 Fax: +49-6227-3091-8100 Email: mxgermany@molex.com Molex Singapore Pte. Ltd. 110, International Road Jurong Town, Singapore 629174 American Headquarters Lisle, Illinois 60532 U.S.A. Phone: +1-800-78MOLEX Fax: +1-630-969-1352 Molex Japan Co. Ltd. 1-5-4 Fukami-Higashi, Yamato-City, Kanagawa, 242-8585 Japan Phone: +65-6-268-6868 Fax: +65-6-265-6044 Phone: +81-46-265-2325 Fax: +81-46-265-2365 EHS6-A_HIO_v02.770 Confidential / Preliminary 2014-08-13 40 About Gemalto Gemalto (Euronext NL0000400653 GTO) is the world leader in digital security with 2011 annual revenues of 2 billion and more than 10,000 employees operating out of 74 offices and 14 Research
& Development centers, located in 43 countries. We are at the heart of the rapidly evolving digital society. Billions of people worldwide increasingly want the freedom to communicate, travel, shop, bank, entertain and work - anytime, everywhere
- in ways that are enjoyable and safe. Gemalto delivers on their expanding needs for personal mobile services, payment security, authenticated cloud access, identity and privacy protection, eHealthcare and eGovernment efficiency, convenient ticketing and dependable machine-to-
machine (M2M) applications. Gemalto develops secure embedded software and secure products which we design and personalize. Our platforms and services manage these secure products, the confidential data they contain and the trusted end-user services they enable. Our inovations enable our clients to offer trusted and convenient digital services to billions of individuals. Gemalto thrives with the growing number of people using its solutions to interact with the digital and wireless world. For more information please visit m2m.gemalto.com, www.facebook.com/gemalto, or Follow@gemaltom2m on twitter. Gemalto M2M GmbH St.-Martin-Str. 60 81541 Munich Germany M2M.GEMALTO.COM
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-03-20 | 824.2 ~ 848.8 | PCB - PCS Licensed Transmitter | Class II permissive change or modification of presently authorized equipment |
2 | 2014-09-18 | 1852.4 ~ 1907.6 | PCB - PCS Licensed Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2019-03-20
|
||||
1 2 |
2014-09-18
|
|||||
1 2 | Applicant's complete, legal business name |
Gemalto M2M GmbH
|
||||
1 2 | FCC Registration Number (FRN) |
0007412448
|
||||
1 2 | Physical Address |
Siemensdamm 50
|
||||
1 2 |
Berlin, N/A 13629
|
|||||
1 2 |
Germany
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
t******@timcoengr.com
|
||||
1 2 |
h******@acbcert.com
|
|||||
1 2 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
QIP
|
||||
1 2 | Equipment Product Code |
EHS6-A
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
A******** H********
|
||||
1 2 | Title |
Manager Certifications
|
||||
1 2 | Telephone Number |
00493********
|
||||
1 2 | Fax Number |
00493********
|
||||
1 2 |
a******@gemalto.com
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
Beijing 7Layers
|
||||
1 2 |
Gemalto M2M GmbH
|
|||||
1 2 | Name |
K****** G******
|
||||
1 2 |
T****** L********
|
|||||
1 2 | Physical Address |
1F, Building B, Qingdong Business Center
|
||||
1 2 |
Siemensdamm 50 Berlin 13629 Germany
|
|||||
1 2 |
Beijing
|
|||||
1 2 |
Berlin, 13629
|
|||||
1 2 |
China
|
|||||
1 2 |
Germany
|
|||||
1 2 | Telephone Number |
86-10******** Extension:
|
||||
1 2 |
49 30********
|
|||||
1 2 | Fax Number |
86-10********
|
||||
1 2 |
49 30********
|
|||||
1 2 |
k******@7layers.com
|
|||||
1 2 |
t******@gemalto.com
|
|||||
app s | Non Technical Contact | |||||
1 2 | Firm Name |
East China Institute of Telecommunications
|
||||
1 2 | Name |
Y**** Z****
|
||||
1 2 | Physical Address |
7F, G Area,No. 668, Beijing East Road
|
||||
1 2 |
Shanghai, 200001
|
|||||
1 2 |
China
|
|||||
1 2 | Telephone Number |
86-21******** Extension:
|
||||
1 2 | Fax Number |
86-21********
|
||||
1 2 |
z******@ecit.org.cn
|
|||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | No | |||||
1 2 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 09/16/2019 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | PCB - PCS Licensed Transmitter | ||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | EHS6-A | ||||
1 2 | GSM/WCDMA Module | |||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Single Modular Approval | ||||
1 2 | Purpose / Application is for | Class II permissive change or modification of presently authorized equipment | ||||
1 2 | Original Equipment | |||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Class II Permissive Change, Minor circuitry for non transmitter portions. Power out is conducted at the antenna terminal. ERP for part 22 is 34.50 dBm and EIRP for part 24 is 31.02 dBm. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install the EHS6-A module. For mobile and fixed operating configurations the antenna gain, including cable loss, must not exceed 6.12 dBi at 1900 MHz and 8.01 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. Under no condition may an antenna gain be used that would exceed the 7W erp Part 22 and the 2W eirp Part 24 power limits. The Grantee is responsible for providing the documentation required for modular use. The responsibility for the use of this module, in all configurations utilized or contemplated, remains with the Grantee. | ||||
1 2 | Power out is conducted at the antenna terminal. ERP for part 22 is 34.50 dBm and EIRP for part 24 is 31.02 dBm. This device is to be used only for mobile and fixed application. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install the EHS6-A module. For mobile and fixed operating configurations the antenna gain, including cable loss, must not exceed 2.15 dBi at 1900 MHz and 2.15 dBi at 850 MHz as defined in 2.1091 for satisfying RF exposure compliance. Under no condition may an antenna gain be used that would exceed the 7W erp Part 22 and the 2W eirp Part 24 power limits. The Grantee is responsible for providing the documentation required for modular use. The responsibility for the use of this module, in all configurations utilized or contemplated, remains with the Grantee. | |||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
East China Institute of Telecommunications
|
||||
1 2 |
UniLab (Shanghai) Co., Ltd.
|
|||||
1 2 | Name |
Z****** Z********
|
||||
1 2 |
W**** R********
|
|||||
1 2 | Telephone Number |
86-21********
|
||||
1 2 |
86-21********
|
|||||
1 2 | Fax Number |
86-21********
|
||||
1 2 |
z******@ecit.org.cn
|
|||||
1 2 |
w******@unilab.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 22H | 824.2 | 848.8 | 2.118 | 0.1 ppm | 245KGXW | ||||||||||||||||||||||||||||||||||
1 | 2 | 22H | 824.2 | 848.8 | 0.566 | 0.1 ppm | 248KG7W | ||||||||||||||||||||||||||||||||||
1 | 3 | 24E | 1850.2 | 1909.8 | 0.859 | 0.1 ppm | 248KGXW | ||||||||||||||||||||||||||||||||||
1 | 4 | 24E | 1850.2 | 1909.8 | 0.33 | 0.1 ppm | 252KG7W | ||||||||||||||||||||||||||||||||||
1 | 5 | 24E | 1852.4 | 1907.6 | 0.259 | 0.1 ppm | 4M05F9W | ||||||||||||||||||||||||||||||||||
1 | 6 | 22H | 826.4 | 846.6 | 0.272 | 0.1 ppm | 4M07F9W | ||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 22H | BC | 824.2 | 848.8 | 2 | 25 Hz | 246KGXW | |||||||||||||||||||||||||||||||||
2 | 2 | 22H | BC | 824.2 | 848.8 | 0.52 | 31 Hz | 248KG7W | |||||||||||||||||||||||||||||||||
2 | 3 | 24E | BC | 1850.2 | 1909.8 | 0.97 | 9 Hz | 246KGXW | |||||||||||||||||||||||||||||||||
2 | 4 | 24E | BC | 1850.2 | 1909.8 | 0.37 | 19 Hz | 246KG7W | |||||||||||||||||||||||||||||||||
2 | 5 | 22H | BC | 826.4 | 846.6 | 0.25 | 32 Hz | 4M05F9W | |||||||||||||||||||||||||||||||||
2 | 6 | 24E | BC | 1852.4 | 1907.6 | 0.22 | 4 Hz | 4M07F9W |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC