all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
TempConfidential User manual | Users Manual | 457.55 KiB | ||||
1 | Cover Letter(s) | |||||||
1 | Test Report | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Test Setup Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info |
1 | TempConfidential User manual | Users Manual | 457.55 KiB |
GWM300 Hardware Interface Overview Version:
DocId:
01 GWM300_HIO_v01 M2M.GEMALTO.COM GWM300 Hardware Interface Overview Page 2 of 35 2 Document Name:
Version:
Date:
DocId:
Status GWM300 Hardware Interface Overview 01 2016-01-26 GWM300_HIO_v01 Confidential / Released GENERAL NOTE THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PROD-
UCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS INFORMATION ON GEMALTO M2M PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE SUBJECT TO CHANGE AT GEMALTO M2M'S DISCRETION. GEMALTO M2M GMBH GRANTS A NON-
EXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT TRANSFER, COPY, MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, GEMALTO M2M GMBH DISCLAIMS ALL WARRANTIES AND LIABILITIES. THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIV-
ERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW. Copyright Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its con-
tents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Copyright 2016, Gemalto M2M GmbH, a Gemalto Company Trademark Notice Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain countries. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corpora-
tion in the United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview Contents 124 Contents Page 3 of 35 0 1 2 3 4 5 Document History ...................................................................................................... 6 Introduction ................................................................................................................. 7 1.1 Related Documents ........................................................................................... 8 Terms and Abbreviations ................................................................................... 8 1.2 Regulatory and Type Approval Information ..................................................... 10 1.3 1.3.1 Directives and Standards.................................................................... 10 1.3.2 Safety Precautions.............................................................................. 13 Product Label................................................................................................... 15 1.4 Product Concept ....................................................................................................... 16 2.1 Key Features at a Glance ................................................................................ 16 3.5 Interface Description ................................................................................................ 19 3.1 Overview .......................................................................................................... 19 Block Diagram.................................................................................................. 20 3.2 Operating Modes ............................................................................................. 21 3.3 Molex Microfit Connector ................................................................................. 22 3.4 3.4.1 RS-232 Interface................................................................................. 23 3.4.2 Power Supply...................................................................................... 23 Power Up/Power Down Scenarios................................................................... 24 3.5.1 Turn GWM300 on ............................................................................... 24 3.5.2 Reset/Restart GWM300...................................................................... 24 3.5.3 Turn GWM300 off ............................................................................... 24 3.5.4 Disconnecting Power Supply .............................................................. 24 SIM Interface.................................................................................................... 25 Status LED....................................................................................................... 25 RF Antenna Interface....................................................................................... 26 3.6 3.7 3.8 Mechanics, Mounting and Packaging ..................................................................... 27 Mechanical Dimensions ................................................................................... 27 4.1 4.2 Packaging ........................................................................................................ 29 Full Type Approval.................................................................................................... 30 Gemalto M2M Reference Setup ...................................................................... 30 5.1 5.2 Restrictions ...................................................................................................... 31 CE Conformity.................................................................................................. 31 5.3 EMC ................................................................................................................. 31 5.4 5.5 Compliance with FCC and IC Rules and Regulations ..................................... 32 6 List of Parts and Accessories.................................................................................. 34 GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview Tables 4 Page 4 of 35 Tables Table 1:
Table 2:
Table 3:
Table 4:
Table 5:
Table 6:
Table 7:
Table 8:
Table 9:
Table 10:
Table 11:
Table 12:
Terms and abbreviations................................................................................... 8 Directives ........................................................................................................ 10 Standards of North American type approval ................................................... 10 Standards of European type approval............................................................. 10 Requirements of quality .................................................................................. 11 Standards of the Ministry of Information Industry of the Peoples Republic of China............................................................................. 12 Toxic or hazardous substances or elements with defined concentration limits................................................................................................................ 12 GWM300 label information.............................................................................. 15 GWM300 interfaces........................................................................................ 19 Overview of operating modes ......................................................................... 21 8-pin Molex Microfit connector ........................................................................ 22 List of parts and accessories........................................................................... 34 GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview Figures 5 Page 5 of 35 Figures Figure 1:
Figure 2:
Figure 3:
Figure 4:
Figure 5:
Figure 6:
Figure 7:
Figure 8:
Figure 9:
Figure 10:
Sample GWM300 labels ................................................................................. 15 GWM300 interfaces ........................................................................................ 19 Block diagram ................................................................................................. 20 Pin assignment Molex Microfit ........................................................................ 22 SIM interface................................................................................................... 25 Status LED...................................................................................................... 25 Antenna connector.......................................................................................... 26 GWM300 3D overview .................................................................................... 27 GWM300 exploded view ................................................................................. 28 Reference equipment for approval.................................................................. 30 GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 0 Document History 6 0 Document History Page 6 of 35 New document: "Cinterion GWM300 Hardware Interface Overview" Version 01 Chapter
--
What is new Initial document setup. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 1 Introduction 15 1 Introduction Page 7 of 35 This document1 describes the hardware of the GWM300. The GWM300 contains a Cinterion EHS6 module, and has an RS-232 compatible interface with an 8-pin Molex Microfit connector, including power supply, and an RF antenna connector. The scope of this document includes interface specifications, electrical as well as mechanical characteristics of the GWM300. It specifies standards pertaining to wireless applications and outlines requirements that must be adhered to for successful product design. The GWM300 is a compact GSM/UMTS modem to transfer data to/from other devices, such as smart meter, to the mobile network. It is easy to use the GWM300 as a GSM/GPRS/UMTS terminal. The GWM300 has an industrial standard serial interface that can be used to transfer data to/from the connected device. The connected device can also send AT commands via this serial interface, to control GWM300. The GWM300 supports quad band GSM and five band UMTS. It has an integrated SIM card reader supporting 1.8V and 3V SIM cards. GWM300 is not intended for use in vehicular environments. 1. The document is effective only if listed in the appropriate Release Notes as part of the technical docu-
mentation delivered with your Gemalto M2M product. GWM300_HIO_v01 Confidential / Released 2016-01-26 Page 8 of 35 GWM300 Hardware Interface Overview 1.1 Related Documents 15 Related Documents 1.1
[1] AT Command Set for the Cinterion EHS6 module
[2] Release Notes for the Cinterion EHS6 module To visit the Gemalto M2M GmbH Website please use the following link:
http://m2m.gemalto.com 1.2 Terms and Abbreviations Table 1: Terms and abbreviations Abbreviation Description ACMA ARP ATC BTS CB CE CODEC DAI DCE DSR DTR EFR EGSM EMC ESD ETS FDMA G.C.F. GSM HW IC IF IMEI I/O IGT ISO Australian Communications and Media Authority Antenna Reference Point AT Command Base Transceiver Station Cell Broadcast Communaut Europenne (originally) Coder-Decoder Digital Audio Interface Data Circuit terminating Equipment Data Set Ready Data Terminal Ready Enhanced Full Rate Enhanced GSM Electromagnetic Compatibility Electrostatic Discharge European Telecommunication Standard Frequency Division Multiple Access GSM Conformity Forum Global Standard for Mobile Communication Hardware Integrated Circuit Intermediate Frequency International Mobile Equipment Identifier Input/ Output Ignition International Standards Organization GWM300_HIO_v01 Confidential / Released 2016-01-26 Page 9 of 35 GWM300 Hardware Interface Overview 1.2 Terms and Abbreviations 15 Table 1: Terms and abbreviations Abbreviation Description ITU kbps LVD Mbps MMI MO MS MT NC PA PCB PCM PCS PD PDU R&TTE RF RI RX SIM SMS SW TDD TDMA TX UART International Telecommunications Union kbits per second Low voltage Directive Mbits per second Machine Machine Interface Mobile Originated Mobile Station Mobile Terminated Not Connected Power Amplifier Printed Circuit Board Pulse Code Modulation Personal Communication System Power Down Protocol Data Unit Radio and Telecommunication Terminal Equipment Radio frequency Ring Indication Receive direction Subscriber Identification Module Short Message Service Software Time Division Duplex Time Division Multiple Access Transmit direction Universal Asynchronous Receiver and Transmitter GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 1.3 Regulatory and Type Approval Information 15 Page 10 of 35 1.3 Regulatory and Type Approval Information Directives and Standards 1.3.1 EHS6 has been designed to comply with the directives and standards listed below. Table 2: Directives 99/05/EC 2002/95/EC (RoHS 1) 2011/65/EC (RoHS 2) Directive of the European Parliament and of the council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (in short referred to as R&TTE Direc-
tive 1999/5/EC). The product is labeled with the CE conformity mark - see Section 5.3. Directive of the European Parliament and of the Council of 27 January 2003 (and revised on 8 June 2011) on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 2002/96/EC 2003/108/EC Directive of the European Parliament and of the Council on waste electri-
cal and electronic equipment (WEEE) Directive of the European Parliament and of the Council of 8 December 2003 amending directive 2002/96/ec on waste electrical and electronic equipment (WEEE) Table 3: Standards of North American type approval CFR Title 47 OET Bulletin 65
(Edition 97-01) UL 60 950-1 NAPRD.03 V5.15 RSS102 (Issue 4) RSS132 (Issue 3) RSS133 (Issue 6) IEEE Std. C95.1-1999 Code of Federal Regulations, Part 15 B, Part 22 and Part 24 (Telecom-
munications, PCS); US Equipment Authorization FCC Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Product Safety Certification (Safety requirements) Overview of PCS Type certification review board Mobile Equipment Type Certification and IMEI control PCS Type Certification Review board (PTCRB) Canadian Standard IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz Table 4: Standards of European type approval 3GPP TS 51.010-1 Digital cellular telecommunications system (Phase 2); Mobile Station
(MS) conformance specification ETSI EN 301 511 V9.0.2 Candidate Harmonized European Standard (Telecommunications series) Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essen-
tial requirements under article 3.2 of the R&TTE directive (1999/5/EC)
(GSM 13.11 version 7.0.1 Release 1998) Global Certification Forum - Certification Criteria GCF-CC V3.49 GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 1.3 Regulatory and Type Approval Information 15 Page 11 of 35 Table 4: Standards of European type approval ETSI EN 301 489-1 V1.9.2 Candidate Harmonized European Standard (Telecommunications series) Electro Magnetic Compatibility and Radio spectrum Matters (ERM); Elec-
tro Magnetic Compatibility (EMC) standard for radio equipment and ser-
vices; Part 1: Common Technical Requirements Candidate Harmonized European Standard (Telecommunications series) Electro Magnetic Compatibility and Radio spectrum Matters (ERM); Elec-
tro Magnetic Compatibility (EMC) standard for radio equipment and ser-
vices; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems
(GSM and DCS) Electromagnetic Compatibility and Radio spectrum Matters (ERM); Elec-
tromagnetic Compatibility (EMC) standard for radio equipment and ser-
vices; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread
(UTRA) for Mobile and portable (UE) radio and ancillary equipment Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 1: Harmonized EN for IMT-2000, introduction and common requirements of article 3.2 of the R&TTE Directive Electromagnetic compatibility and Radio spectrum Matters (ERM); Base Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation cellular networks; Part 2: Harmonized EN for IMT-2000, CDMA Direct Spread (UTRA FDD) (UE) covering essential requirements of article 3.2 of the R&TTE Directive Assessment of electronic and electrical equipment related to human expo-
sure restrictions for electromagnetic fields (0 Hz - 300 GHz) Safety of information technology equipment ETSI EN 301 489-7 V1.3.1 ETSI EN 301 489-24 V1.5.1 ETSI EN 301 908-01 V5.2.1 ETSI EN 301 908-02 V5.2.1 EN 62311-2008 EN 60950-1 (2006)+
A11:2009+A1:2010+
AC:2011+A12:2011 Table 5: Requirements of quality IEC 60068 DIN EN 60529 Environmental testing IP codes GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 1.3 Regulatory and Type Approval Information 15 Page 12 of 35 Table 6: Standards of the Ministry of Information Industry of the Peoples Republic of China SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Sub-
stances in Electronic Information Products (2006-06). Marking for Control of Pollution Caused by Electronic Information Products (2006-06). SJ/T 11364-2006 According to the Chinese Administration on the Control of Pollution caused by Electronic Information Products
(ACPEIP) the EPUP, i.e., Environmental Protection Use Period, of this product is 20 years as per the symbol shown here, unless otherwise marked. The EPUP is valid only as long as the product is operated within the operating limits described in the Hard-
ware Interface Description. Please see Table 1.3.2 for an overview of toxic or hazardous substances or elements that might be contained in product parts in concentrations above the limits defined by SJ/T 11363-2006. Table 7: Toxic or hazardous substances or elements with defined concentration limits GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 1.3 Regulatory and Type Approval Information 15 1.3.2 Safety Precautions Page 13 of 35 The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating GWM300. Manufacturers of the cellular terminal are advised to convey the following safety information to users and oper-
ating personnel and incorporate these guidelines into all manuals supplied with the product. Failure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Gemalto M2M GmbH assumes no liability for customers failure to comply with these precautions. When in hospitals or other health care facilities, observe the restrictions on the use of mobiles. Switch off the cellular terminal or mobile if to be instructed to do so by the guidelines posted in sensitive areas. Medical equipment may be sensitive to RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufacturer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their hand-held mobile away from the pacemaker, while it is on. This personal subgroup always should check the distance to the mobile. Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it cannot be switched on inadvertently. The operation of wireless appliances in an air-
craft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both. Check the local and actual laws about these themes. Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where blasting operations are in progress. Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety hazard. Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special regula-
tions and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger. Road safety comes first! Do not use a hand-held cellular terminal or mobile while driving a vehicle unless it is securely mounted in a holder for speakerphone opera-
tion. Before making a call with a hand-held terminal or mobile park the vehicle. Speakerphones must be installed by qualified personnel. Faulty installation or oper-
ation can constitute a safety hazard. Check the actual and local laws about these themes. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 1.3 Regulatory and Type Approval Information 15 Page 14 of 35 IMPORTANT!
Cellular terminals or mobiles operate using radio signals and cellular networks. In that case connections cannot be guaranteed at all times under all conditions. There-
fore, you should never rely solely upon any wireless device for essential communi-
cations, for example emergency calls. Remember, in order to make calls or receive calls the cellular terminal or mobile must be switched on in a service area with adequate cellular signal strength. Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate those features before you can make an emergency call. Some networks require a valid SIM card to be properly inserted in the cellular ter-
minal or mobile. If a power supply unit is used to supply the device it must meet the demands placed on SELV circuits in accordance with EN60950. The maximum permissible connec-
tion length between the device and the supply source should not exceed 3m. According to the guidelines for human exposure to radio frequency energy, an antenna connected to the FME jack of the device should be placed at least 20cm away from human bodies. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 1.4 Product Label 15 1.4 Product Label The labels fixed to the bottom of a GWM300 comprise the following information. Page 15 of 35 1 3 4 5 7 8 9 2 6
10 11 Figure 1: Sample GWM300 labels Table 8: GWM300 label information No. 1 2 3 4 5 6 7 8 9 10 11 Information Product name Product series/family Product group Manufacturing code CE logo (including notified body number) RCM logo (ACMA Regulatory Compliance Mark) Products serial number (also as Barcode 128 type C) Products IMEI (also as Barcode 128 type C) Company logo Marking "Made in China"
Year of manufacture GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 2 Product Concept 18 2 2.1 Product Concept Key Features at a Glance Page 16 of 35 Feature General Incorporates Cinterion Java module Implementation The Java module handles all signal and data processing within the GWM300. Internal software runs the application interface and the complete GSM/UMTS protocol stack. Frequency bands GWM300 (with EHS6 module):
GSM/GPRS/EDGE: Quad band 850/900/1800/1900MHz UMTS/HSPA+: Five band 800/850/900/1900/2100MHz GSM class Small MS Output power (according to Release 99, V5) depending on frequency band supported by mod-
ule Power supply Operating temperature
(ambient temperature) Physical HSPA features 3GPP Release 6,7 UMTS features 3GPP Release 4 Class 4 (+33dBm 2dB) for EGSM850 Class 4 (+33dBm 2dB) for EGSM900 Class 1 (+30dBm 2dB) for GSM1800 Class 1 (+30dBm 2dB) for GSM1900 Class E2 (+27dBm 3dB) for GSM 850 8-PSK Class E2 (+27dBm 3dB) for GSM 900 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK Class 3 (+24dBm +1/-3dB) for UMTS 2100, WCDMA FDD BdI Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII Class 3 (+24dBm +1/-3dB) for UMTS 900, WCDMA FDD BdVIII Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV Class 3 (+24dBm +1/-3dB) for UMTS 800, WCDMA FDD BdVI The values stated above are maximum limits. According to Release 99, the maximum output power in a multislot configuration may be lower. The nom-
inal reduction of maximum output power varies with the number of uplink timeslots used and amounts to 3.0dB for 2Tx. Single supply voltage 5V to 26V Normal operation: -25C to +70C Dimensions: 71mm x 51.5mm x 23.5mm
(excluding antenna and serial interface connectors) Weight: 60g (approx.) DL 7.2Mbps, UL 5.7Mbps HSDPA Cat.8 / HSUPA Cat.6 data rates Compressed mode (CM) supported according to 3GPP TS25.212 PS data rate 384 kbps DL / 384 kbps UL CS data rate 64 kbps DL / 64 kbps UL GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 2.1 Key Features at a Glance 18 Page 17 of 35 Feature GSM / GPRS / EDGE features Data transfer Implementation Full PBCCH support EDGE E2 power class for 8 PSK GPRS:
Multislot Class 12 Mobile Station Class B Coding Scheme 1 4 EGPRS:
Multislot Class 12 Downlink coding schemes CS 1-4, MCS 1-9 Uplink coding schemes CS 1-4, MCS 1-9 NACC, extended UL TBF Mobile Station Class B CSD:
USSD Cell broadcast SRB loopback and test mode B 8-bit, 11-bit RACH PBCCH support 1 phase/2 phase access procedures Link adaptation and IR V.110, RLP, non-transparent 2.4, 4.8, 9.6, 14.4kbps Point-to-point MT and MO Text and PDU mode SMS Software AT commands Java Open Platform SIM Application Toolkit TCP/IP stack Firmware update Hayes 3GPP TS 27.007, TS 27.005, Gemalto M2M Java Open Platform with Multi-threading programming and multi-application execution Java profile IMP-NG & CLDC 1.1 HI Secure data transmission via HTTPS/SSL Major benefits: seamless integration into Java applications, ease of pro-
gramming, no need for application microcontroller, extremely cost-efficient hardware and software design ideal platform for industrial GSM applica-
tions. The memory space available for Java programs is around 10MB in the flash file system and around 10MB RAM. Application code and data share the space in the flash file system and in RAM. SAT Release 99 Protocols: TCP server/client, UDP, HTTP, FTP, SMTP, POP3 Access by AT commands Upgradeable via serial RS-232 interface or FOTA GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 2.1 Key Features at a Glance 18 Page 18 of 35 Feature Interfaces RS232 Power supply SIM card reader Antenna Power on/off, Reset Power on Power off Reset Special features Status indication Real time clock Phonebook Implementation Supports RTS/CTS hardware handshake Supports software XON/XOFF flow control RS-232 interface as part of 8-pin Molex Microfit for AT commands and data:
Multiplex ability according to GSM 07.10 Multiplexer protocol Baud rates from 1200bps to 921,600bps Autobauding supported Power supply (BATT+) as part of 8-pin Molex Microfit Supported SIM cards: 3V, 1.8V Antenna connected via female SMA connector Power supply line at power connector Normal switch-off by AT^SMSO Orderly shutdown and reset by AT command LED to indicate operating status. Timer functions via AT commands SIM card and terminal GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 3 Interface Description 26 Page 19 of 35 Interface Description Overview 3 3.1 GWM300 provide the following interfaces for power supply, operating status indication, anten-
na, SIM card and data transfer:
Table 9: GWM300 interfaces No. 1 2 3 4 Description SIM card reader (FF2, rubber cover, no hot plug) LED (green) showing operating status LED 8-pin Molex Microfit connector (female) for data transfer (RS-232 interface) and power supply FME connector (female) for RF antenna Front view Back view 1 2 3 4 Figure 2: GWM300 interfaces GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 3.2 Block Diagram 26 3.2 Block Diagram Page 20 of 35 Figure 3 shows a block diagram of a sample configuration that incorporates a GWM300 and typical accessories. RF antenna interface RF antenna interface Antenna Host controller Power supply EHS6 RS-232 driver Power regulation SIM card interface SIM card LED GWM300 External application Figure 3: Block diagram GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 3.3 Operating Modes 26 3.3 Operating Modes Page 21 of 35 The table below briefly summarizes the various operating modes referred to in the following chapters. Table 10: Overview of operating modes Normal operation GSM IDLE GSM TALK GSM DATA GPRS / UMTS / HSPA IDLE GPRS DATA EGPRS DATA UMTS TALK UMTS DATA HSPA DATA Software is active. Once registered to the GSM network paging with BTS is carried out. The Terminal is ready to send and receive. Watchdog active. Connection between two subscribers is in progress. Power consumption depends on network coverage indi-
vidual settings, such as DTX off/on, FR/EFR/HR, hop-
ping sequences, antenna. Watchdog active. Terminal is ready for GPRS data transfer, but no data is currently sent or received. Power consumption depends on network settings and GPRS configuration (e.g. multis-
lot settings). Watchdog active. GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates, GPRS configuration (e.g. used multislot settings) and reduction of maximum out-
put power. Watchdog active. EGPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates, EGPRS configuration (e.g. used multislot settings) and reduction of maximum out-
put power. Watchdog active. UMTS data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. Watchdog active. HSPA data transfer in progress. Power consumption depends on network settings (e.g. TPC Pattern) and data transfer rate. Watchdog active. Power Down Normal shutdown after sending the AT^SMSO command. The RTC works continuously, but the software is not active. Interfaces are not accessible. To restart GWM300 the power supply has to be turned off and on again. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 3.4 Molex Microfit Connector 26 3.4 Molex Microfit Connector Page 22 of 35 Via the 8-pin Molex Microfit connector, the host application controller controls the GWM300 (in-
cluding power supply), and transports data. Figure 4: Pin assignment Molex Microfit Table 11: 8-pin Molex Microfit connector I/O Pin no. 1 I I 2 O 3 4 O O 5 6
-
I 7 8 I Signal name BATT+
DTR0 RXD0 CTS0 DCD0 GND TXD0 RTS0 Function Power Supply (5-26V DC; 3W maximum including peaks) Data Terminal Ready Receive Data Clear To Send Data Carrier Detected Ground Transmit Data Request To Send The Molex Microfit connector implements an RS-232 interface (see Section 3.4.1) as well as the power supply line (see Section 3.4.2). The GWM300s Molex Microfit (3.0) connector, i.e., the header (series number: 430450822) mates with the Molex Microfit (3.0) receptacle (series number: 430250800). GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 3.4 Molex Microfit Connector 26 3.4.1 RS-232 Interface Page 23 of 35 The RS-232 interface is implemented as a serial asynchronous transmitter and receiver con-
forming to ITU-T V.24 Interchange Circuits DCE. Based on the conventions for DCE-DTE con-
nections it communicates with the host application (DTE) using the following signals:
Port TxD @ application sends data to TXD0 of the GWM300 Port RxD @ application receives data from RXD0 of the GWM300 The serial interface (also called ASC0) is configured for 8 data bits, no parity and 1 stop bit, and is by default operated at a fixed baud rate of 9600bps, but can be configured for bit rates from 1200bps to 921kbps. Autobauding supports bit rates from 1.2kbps to 230kbps. Hardware hand-
shake using the RTS0 and CTS0 signals and XON/XOFF software flow control are supported. In addition, the modem control signals DTR0 and DCD0 are available. There are different modes of operation that can be set with AT commands. Power Supply 3.4.2 The power supply of the GWM300 has to be a single voltage source of VPLUS=5V26V capable of providing a peak current of about 2.5A at 15V during an active transmission. The uplink burst causes strong ripple (drop) on the power lines. The absolute minimum voltage during drops must be >5V. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 3.5 Power Up/Power Down Scenarios 26 3.5 Power Up/Power Down Scenarios Page 24 of 35 In general, be sure not to turn on the GWM300 while it is beyond the safety limits of voltage stated in Section 4.1. GWM300 immediately switches off after having started and detected these inappropriate conditions. In extreme cases this can cause permanent damage to the GWM300. Turn GWM300 on 3.5.1 GWM300 is automatically turned on and started into normal mode by plugging or by re-plug-
ging an appropriate power supply unit at the power supply line BATT+. 3.5.2 Reset/Restart GWM300 GWM300 can be reset/restarted by entering the command AT+CFUN=x,1. For details on AT+CFUN please see [1]. 3.5.3 Turn GWM300 off Normal shutdown:
To turn off the GWM300 use the AT^SMSO command, rather than disconnecting the mains adapter. This switch off procedure lets the GWM300 log off from the network and allows the software to enter a secure state and save data before disconnecting the power supply. After AT^SMSO has been entered the GWM300 returns the following result codes:
^SMSO: MS OFF OK
^SHUTDOWN The "^SHUTDOWN" result code indicates that the GWM300 turns off in less than 1 second. After the shutdown procedure is complete the GWM300 enters the Power Down mode. The RTC is still fed from the voltage regulator in the power supply ASIC. Only after power off and power on again, i.e., turning off and on the power supply line, can the terminal be switches on again. Apart from teh normal shutdown 3.5.4 Disconnecting Power Supply Before disconnecting the power supply from the BATT+ pin, make sure that the GWM300 is in a safe condition. The best way is to wait 1s after the "^SHUTDOWN" result code has been in-
dicated. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 3.6 SIM Interface 26 3.6 SIM Interface Page 25 of 35 The SIM interface is intended for 1.8V and 3V SIM cards in accordance with GSM 11.12 Phase 2. The card holder is a five wire interface according to GSM 11.11. The SIM card holder is pro-
tected by a rubber cover that has to be opened before a SIM can be inserted. Figure 5: SIM interface SIM card reader The SIM - with the circuit side facing upwards - is inserted by gently pushing it into the SIM card holder until it snaps hold. It is now protected from accidental removal. The SIM can be removed from the card holder by using a flat object such as a screwdriver to carefully press the inserted SIM until it snaps out again. All signals of the SIM interface are protected from electrostatic discharge. Removing and inserting the SIM card during operation requires is not supported by GWM300. Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after removing the SIM card during operation. Also, no guarantee can be given for properly initializ-
ing any SIM card that the user inserts after having removed a SIM card during operation. In this case, the application must restart the GWM300. Status LED 3.7 GWM300 has a green LED to indicate its operating status. Figure 6: Status LED Status LED The LED is enabled by default, but can be configured by AT command AT^SLED. For more information on the AT^SLED command please refer to [1]. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 3.8 RF Antenna Interface 26 3.8 RF Antenna Interface Page 26 of 35 An external RF antenna is connected via the GWM300s female FME connector that is also the antenna reference point (ARP). Figure 7: Antenna connector The system impedance is 50. In any case, for good RF performance, the return loss of the customer applications antenna should be better than 10dB (VSWR < 2). GWM300 withstand a total mismatch at this connector when transmitting with maximum RF power. Additional ESD protection to the antenna connector is provided. No DC voltage must be applied to the antenna circuit to protect it from damage. Please note that the terminal should be installed and operated with a minimum distance of 20cm between the antenna connected to the terminal and any human bodies. Also, the trans-
mitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antenna's character impedance should be 50. It it recommended that the antenna should have VSWR <=2:1, within the working band frequency range. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 4 Mechanics, Mounting and Packaging 29 4 4.1 Mechanics, Mounting and Packaging Mechanical Dimensions Page 27 of 35 Figure 8 shows a 3D view of the GWM300 and provides an overview of the mechanical dimen-
sions of the terminal. For further details and an exploded view see Figure 9. Length:
Width:
Height:
71mm (excluding antenna and connector interfaces) 51.5mm 23.5mm Weight:
60g 23.5mm 51.5mm 71mm Figure 8: GWM300 3D overview GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 4.1 Mechanical Dimensions 29 Page 28 of 124 Figure 9: GWM300 exploded view GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 4.2 Packaging 29 4.2 Packaging Page 29 of 35 GWM300 terminal units come in bubble bags stashed into VP boxes made out of corrugated fiberboard:
VP box size: 370mm x 350mm x 155mm A VP box contains up to 80 terminal units, stashed into two layers of up to 40 units. Terminal layers are separated by foam layers for protective purposes. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 5 Full Type Approval 33 5 5.1 Full Type Approval Gemalto M2M Reference Setup Page 30 of 35 The Gemalto M2M reference setup submitted to type approve GWM300 consists of the follow-
ing components:
GWM300 with approved Java module PC as MMI Power Supply RS-232/power supply cable (modified from DB9-RJ45 connector adapter) Antenna or 50Ohm cable to the system simulator RS-232/
power supply Terminal 8-pin Microfit Connector PC SIM Power supply Figure 10: Reference equipment for approval For ordering information please refer to Chapter 6. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 5.2 Restrictions 33 5.2 Restrictions Page 31 of 35 Later enhancements and modifications beyond the certified configuration require extra approv-
als. Each supplementary approval process includes submittal of the technical documentation as well as testing of the changes made. No further approvals are required for customer applications that comply with the approved GWM300 configuration. Extra approval must be obtained for applications using other accessories than those included in the approved GWM300 configuration (power supply, MMI implementation sup-
ported by AT commands). 5.3 CE Conformity GWM300 meets the requirements of the EU directives listed below:
R&TTE Directive 1999/5/EC GWM300 is marked with the CE conformity mark (including notified body number):
GWM300 5.4 EMC GWM300 complies with the equipment requirements specified in EN 301489-1, -7 and -24 are covered by the R&TTE Directive. For details see Section 1.3. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 5.5 Compliance with FCC and IC Rules and Regulations 33 Page 32 of 35 5.5 Compliance with FCC and IC Rules and Regulations As an integrated product, GWM300 is fully compliant with the grant of the FCC Equipment Au-
thorization and the Industry Canada Certificates issued for the built-in Java modules, and there-
fore, bears the labels Contains FCC ID: QIPEHS6. The Equipment Authorization Certification for the included Cinterion module is listed under the following identifiers:
FCC Idenitifier: QIPEHS6 Industry Canada Certification Number: 7830A-EHS6 Granted to Gemalto M2M GmbH Notes (FCC):
Radiofrequency radiation exposure Information:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled envi-
ronment. This equipment should be installed and operated with minimum distance of 20 cm be-
tween the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This terminal equipment has been tested and found to comply with the limits for a Class B dig-
ital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reason-
able protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accor-
dance with the instructions, may cause harmful interference to radio communications. Howev-
er, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be de-
termined by turning the equipment off and on, the user is encouraged to try to correct the inter-
ference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is Increase the separation between the equipment and receiver. connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications made to this equipment not expressly approved by Gemalto M2M may void the FCC authorization to operate this equipment. This device contains UMTS, GSM and GPRS class functions in the 900, 1800 and 2100MHz bands that are not operational in U.S. Territories. This device is to be used only for mobile and fixed applications. Users and installers must be provided with antenna installation instructions and transmitter op-
erating conditions for satisfying RF exposure compliance: For more information on the RF an-
tenna interface please refer to Section 3.8 and Section 4.4. GWM300_HIO_v01 Confidential / Released 2016-01-26 GWM300 Hardware Interface Overview 5.5 Compliance with FCC and IC Rules and Regulations 33 Page 33 of 35 Notes (IC):
(EN) This Class B digital apparatus complies with Canadian ICES-003 and RSS-210. Opera-
tion is subject to the following two conditions: (1) this devive may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
(FR) Cet appareil numrique de classe B est conforme aux normes canadiennes ICES-003 et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas causer d'interfrence et (2) cet appareil doit accepter toute interfrence, notamment les interfrences qui peuvent affecter son fonctionnement.
(EN) Radio frequency (RF) Exposure Information The radiated output power of the Wireless Device is below the Industry Canada (IC) radio fre-
quency exposure limits. The Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized. This device has also been evaluated and shown compliant with the IC RF Exposure limits un-
der mobile exposure conditions. (antennas are greater than 20cm from a persons body).
(FR) Informations concernant l'exposltion aux frquences radio (RF) La puissance de sortie mise par l'appareil de sans fiI est infrieure la limite d'exposition aux frquences radio dIndustry Canada (IC). Utilisez l'appareil de sans fil de faon minimiser les contacts humains lors du fonctionnement normal. Ce priphrique a galement t valu et dmontr conforme aux limites d'exposition aux RF d'IC dans des conditions d'exposition des appareils mobiles (les antennes se situent moins de 20cm du corps d'une personne). GWM300_HIO_v01 Confidential / Released 2016-01-26 Page 34 of 35 GWM300 Hardware Interface Overview 6 List of Parts and Accessories 34 6 List of Parts and Accessories Table 12: List of parts and accessories Description GWM300 8-pin receptacle Molex Microfit (3.0) Supplier Gemalto Molex Ordering information Ordering number L30960-N4300-A100 Ordering number 43025-0800 GWM300_HIO_v01 Confidential / Released 2016-01-26 35 About Gemalto Gemalto (Euronext NL0000400653 GTO) is the world leader in digital security with 2014 annual revenues of 2.5 billion and blue-chip customers in over 180 countries. Our 14,000 employees operate out of 99 offices, 34 personalization and data centers, and 24 research and software development centers located in 46 countries. We are at the heart of the rapidly evolving digital society. Billions of people worldwide increasingly want the freedom to communicate, travel, shop, bank, entertain and work - anytime, everywhere
- in ways that are enjoyable and safe. Gemalto delivers on their expanding needs for personal mobile services, payment security, authenticated cloud access, identity and privacy protection, eHealthcare and eGovernment efficiency, convenient ticketing and dependable machine-to-
machine (M2M) applications. Gemalto develops secure embedded software and secure products which we design and personalize. Our platforms and services manage these secure products, the confidential data they contain and the trusted end-user services they enable. Our innovations enable our clients to offer trusted and convenient digital services to billions of individuals. Gemalto thrives with the growing number of people using its solutions to interact with the digital and wireless world. For more information please visit m2m.gemalto.com, www.facebook.com/gemalto, or Follow@gemaltom2m on twitter. Gemalto M2M GmbH St.-Martin-Str. 60 81541 Munich Germany M2M.GEMALTO.COM 3 1 0 2 l i r p A
. s e i r t n u o c i n a t r e c n i i d e r e t s g e r e r a d n a o t l a m e G f o s k r a m e c v r e s i d n a s k r a m e d a r t e r a
, o g o l o t l a m e G e h t
, o t l a m e G
. d e v r e s e r s t h g i r l l A
. 6 1 0 2 o t l a m e G
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2016-03-22 | JBP - Part 15 Class B Computing Device Peripheral | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2016-03-22
|
||||
1 | Applicant's complete, legal business name |
Gemalto M2M GmbH
|
||||
1 | FCC Registration Number (FRN) |
0007412448
|
||||
1 | Physical Address |
Siemensdamm 50
|
||||
1 |
Berlin, N/A 13629
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
QIP
|
||||
1 | Equipment Product Code |
GWM300
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
A****** H******
|
||||
1 | Title |
Manager Certifications
|
||||
1 | Telephone Number |
00493********
|
||||
1 | Fax Number |
00493********
|
||||
1 |
a******@gemalto.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Gemalto M2M GmbH
|
||||
1 | Name |
T**** L********
|
||||
1 | Physical Address |
Siemensdamm 50 Berlin 13629 Germany
|
||||
1 |
Berlin
|
|||||
1 |
Germany
|
|||||
1 | Telephone Number |
49 30********
|
||||
1 | Fax Number |
49 30********
|
||||
1 |
t******@gemalto.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 09/13/2016 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | JBP - Part 15 Class B Computing Device Peripheral | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | EHS6 GSM/WCDMA Terminal | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
UniLab (Shanghai) Co., Ltd.
|
||||
1 | Name |
W****** R****
|
||||
1 | Telephone Number |
86-21********
|
||||
1 | Fax Number |
86-21********
|
||||
1 |
w******@unilab.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC