User Manual System Overview TM-915 is designed of 902MHz to 928MHz reader module for UHF RFID, usually applied to PC . Our advance technology delivers small, reliable, easy to design and cost-effective EPC C1G2 UHF reader module solution. TM-915 also compatible with ISO-18000-6C. Its simplified Uart interface, low power consumption and high performance, make it easily to integrate any device with UHF technology. PC system: Windows XP/Vista/7/8 (32 & 64-bit) USB to UART driver Above Net_Framework_4.0 FAVEPC Reader Utility software 1. First install PL2303_Prolific_DriverInstaller_v1_12_0 file. The file download Web side refer to the below http://www.prolific.com.tw/UserFiles/files/PL2303_Prolific_DriverInstaller_v1_14_0.zip 2. Install process:
Step 1: Next Step 2: Finish and PC restart 3. Install the above Net_Framework_4.0 fileThe file download Web side refer to the below https://www.microsoft.com/zh-tw/download/details.aspx?id=17718 4. USB Reader plug to PC USB port and Run Reader Utility softwarerefer to the below:
Check the boxEnter Readerand Enter the operating window. Operating command refers to the below:
1.1 Q command Read EPC data from single TAG. Check the boxEPC(Q). It can read TAG EPC data. If it need continue to read single TAG. First check the boxCont.and check the boxEPC(Q)again. Check the boxSTOP. It stops to read the TAG EPC. 1.2 U command Read many EPC data from multi-TAG. First check the boxMulti and check the boxEPC(U) If it need continue to read Multi-TG. First check the boxCont.andMulti, check the boxEPC(U). check the boxSTOP. It stops to read multi TAG. 1.3 TIDbutton Real command is <LF>R2,0,4<CR>. It can see the real command in Info windows at lower right corner. TheTIDbutton is used to read single TAG. If it need continue to read single TAG, check the boxCont. and check theboxTID. check the boxSTOP. It stops to read multi TAG. 1.4 R command (Read operation) 1.4.1 First select the Memory BankDrop-down menu:00:RESERVED 01:EPC02:TID03:USER00:RESERVED KillPwd00:RESERVED AccessPwd 1.4.2 Enter number inAddressandLength(word) 1.4.3 Check the BoxRead to get the data. 1.5 W command (Write operation) 1.5.1 First select theMemory Bank 1.5.2 Enter number inAddress and Length(word) 1.5.3 Enter the HEX data to the write windows 1.5.4 Check the boxWrite. The result show in Info windows at lower right corner. If it is right, it show the <LF>W<OK><CR><LF>. 1.5.5 Check the boxRead. It can get the data if it writes data to the TAG. 1.6 Lock operation 1.6.1 Check the box from Kill pwd options. It can select four items. 1.6.1.1 skipnot change 1.6.1.2 Readable and writableTAG can be Readable and writable 1.6.1.3 Permanently Readable and writableTAG can be Permanently Readable and writable. It cant be change the status after the setting. 1.6.1.4 Need password to readable and writableTAG need password to readable and writable 1.6.1.5 Need password to permanently readable and writableTAG need password to permanently readable and writable. It cant be change the status after the setting. 1.6.2 Check the box from Access pwd options. It can select four items. 1.6.2.1 skipnot change 1.6.2.2 Readable and writableTAG can be Readable and writable 1.6.2.3 Permanently Readable and writableTAG can be Permanently Readable and writable. It cant be change the status after the setting. 1.6.2.4 Need password to readable and writableTAG need password to readable and writable 1.6.2.5 Need password to permanently readable and writableTAG need password to permanently readable and writable. It cant be change the status after the setting. 1.6.3 Check the box from EPC bank options. It can select four items.
*EPC data always can be read. 1.6.3.1 skipnot change 1.6.3.2 WritableTAG can be writable 1.6.3.3 Permanently writableTAG can be permanently writable. It cant be change the status after the setting. 1.6.3.4 Need password to writableTAG need password to writable 1.6.3.5 Need password to permanently writableTAG need password to permanently writable. It cant be change the status after the setting. 1.6.4 Check the box from TID bank options. It can select four items.
*TID data always can be read. Normal TAG TID cant be written. It need refer to the TAG IC specification. 1.6.4.1 skipnot change 1.6.4.2 WritableTAG can be writable 1.6.4.3 Permanently writableTAG can be permanently writable. It cant be change the status after the setting. 1.6.4.4 Need password to writableTAG need password to writable 1.6.4.5 Need password to permanently writableTAG need password to permanently writable. It cant be change the status after the setting. 1.6.5 Check the box from USER bank options. It can select four items.
*USER bank data always can be read. 1.6.5.1 skipnot change 1.6.5.2 WritableTAG can be writable 1.6.5.3 Permanently writableTAG can be permanently writable. It cant be change the status after the setting. 1.6.5.4 Need password to writableTAG need password to writable 1.6.5.5 Need password to permanently writableTAG need password to permanently writable. It cant be change the status after the setting 1.6.6 For example. We will select (Need password to readable and writable) option at all item. Check the boxLock. The result show in Info windows at lower right corner. If it is right, it show the
<LF>L<OK><CR><LF>. 1.7 Kill Password Setting 1.7.1 AtMemory Bankof Read/Write operation itemDrop-down menu select00:RESERVED KillPwditem. 1.7.2 Check the boxReadDefault value is 0000000 1.7.3 For example. Write password is 12345678check the BoxWrite. The result show in Info windows at lower right corner. If it is right, it show the <LF>W<OK><CR><LF>
1.8 Access Password Setting 1.8.1 AtMemory Bankof Read/Write operation itemDrop-down menu select00:RESERVED AccessPwd 1.8.2 Check the boxReadDefault value is 0000000 1.8.3 For example. Write password is 12345678check the BoxWrite. The result show in Info windows at lower right corner. If it is right, it show the <LF>W<OK><CR><LF>
1.9 P command:
1.9.1 The all operations are be locked the password. So we need use P command before the other command operates. 1.9.2 Write the password (12345678) at Access Password item 1.9.3 Check the boxSet access to pre-command 1.9.4 We can read TAG to get the EPC data. 1.9.5 We can see the information in Info windows at lower right corner. The R command. It isnt need the password to read EPC data. Because the EPC data always can be read. But we need write the ECP data. If it doesnt run the P command, it will resend the error code (4). It means the memory is locked. So we run the P command first and immediately run W command. It can write data to EPC bank memory. 1.10 Kill command 1.10.1 Enter kill password 12345678 at Kill pwd item 1.10.2 Check the boxKill. The TAG will be kill and cant be used again. 1.11 T command ---Select TAG operation 1.11.1 It need select one TAG operation at Multi-TAG. It need use the T Command to select specific TAG. 1.11.2 Check the boxMultifirst and check the boxEPC(U) 1.11.3 It show the Multi-TAG data at Top right of the window 1.11.4 At Pre-setting item 1.11.4.1 Check the boxSet select to pre-command 1.11.4.2 Select01:EPCat Memory Bank 1.11.4.3 Enter number(70) at Address(bit)
*Warning : Address unit is bit, the value is HEX. So HEX(7*16)=HEX(112)=70 hex 1.11.4.4 Enter number (10) at Length(bit)
* Warning : Length unit is bit, the value is HEX. So HEX(1*16)=HEX(16)=10 hex 1.11.4.5 Enter last four numbers of EPC at Data item. For example. The number is 8DE0 or 8DDF. 1.11.5 At Read/Write item 1.11.5.1 Select01:EPCat Memory Bank 1.11.5.2 Check the boxRead. We can get the EPC data by selected TAG 1.11.6 It shows the command process in Info windows at lower right corner. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Statement:
Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.