UE600 User Guide TM951326 - 01 April 16, 2015 Copyright 2015 GIGA-TMS INC. Printed in Taiwan Any part of the contents of this document, without the express written GIGA-TMS permission, shall not in any documents, electronic, mechanical form of remakes or spread. File contents are subject to change without notice. Revisions Date Description April 16, 2015 preliminary draft Revision 01 Has been tested in accordance to essential protection requirements of the R&TTE Directive 1999/5/EC on the approximation of the laws of the Member States relating to Radio Spectrum Matters and found the test results indeed meet the limitation of the relevant test standard(s) listed below:
EMC Radio Spectrum Safety EN 301 489 - 1: V1.9.2 EN 302 208 - 2: V1.4.1 :
(2011) 2011 EN 301 489 - 3: V1.6.1 EN 302 208 - 1: V1.4.1 :
(2013) 2011 EN 60950-1:2006+A11:2009+A1:2010+
A12:2011+A2:2013 Test standard: FCC rules Part 15 subpart C 15.247 (2013 - 10) Test Result: No deviations from the technical specification(s) were ascertained in the course of the tests performed. Test standard: FCC rules Part 15 subpart B Test Result: Radiated Emission. FCC Part 15. 109 / 15.107 Class B. Test passed. Warning Federal Communication Commission (FCC) Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Contents Chapter 1Introduction...........................................................................1 Chapter 2About UE600 .........................................................................2 Specification........................................................................................................ 2 LED Indication ..................................................................................................... 3 Chapter 3How to Use UE600................................................................4 Before Installing .................................................................................................. 4 Start to Use UE600 .............................................................................................. 4 Chapter 4Troubleshooting ...................................................................5 Contact us..................................................................................................6 UE600 User Guide Chapter 1Introduction Introduce The UE600 is a desktop Ultra High Frequency RFID Reader compliant to ISO18000-6C EPC Gen 2 protocol with an operating range of 840 to 960 MHz. And UE600 also easy to use USB HID to connect PC and have auto sensor which can auto read write Tag. The software UE600 Tag Issuer is supplied with the reader for Tag reading and writing. Before using the UE600 Reader. We recommend that you should already read this user guide. Fitting UE600 include antenna. The appearance as shown below UE600 Top view UE600 USB Interface Please download software or user guide from following link:
http://ftp.gigatms.com.tw/disks/disk5472/
60cm USB cable table 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 1 UE600 User Guide Chapter 2About UE600 Europe UE600-30 865~868 MHz USA UE600-00 Specification UE600 Standard RFID spec Frequency Range RF power Interface Power Require Standby : 110mA@5VDC Max 16dBm USB HID ISO 18000-6C, EPC Class1 Gen2 902~928 MHz RF Reading Range Dimension Physical Characteristics Weight Environment parameter Temperature Humidity Working : 300mA@5VDC, Min power require : 500mA@ 5VDC Max 20 cm (depending on Tag) L: 120mm / W: 86mm / H: 79mm 150g ( not Include USB cable ) Operating : -10C ~ 60C Storage : -15C ~ 65C Operating : 10% ~ 90% (no coagulation) Storage : Max 90% (no coagulation) Regulatory approvals Authentication CE R&TTE EN 302 208-1/-2 EN 301 489-1/-3 EN 60950-1 ESD Conduct : 6kv , Air : 8kv FCC ID PART 15B/C 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 2 UE600 User Guide LED Indication Status / Color Power / Red Read / Green Write / Yellow Power ON ON OFF Standby OFF Read Success Read Fail OFF ON Write Success Write Fail ON ON OFF ON ON OFF OFF ON ON ON ON ON ON Buzzer / Beep a beep OFF a beep 3 beeps a beep 3 beeps 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 3 UE600 User Guide Chapter 3How to Use UE600 Before Installing Before Install UE600. Please make sure the following items are ready. A computer (Window XP / Vista / 7 or higher version systems) which already installed UHF Tag Manager. A UE600 reader with USB cable. UHF Tags (ISO18000 Class 1 Gen 2). Start to Use UE600 Connecting UE600 on USB port of your PC. Executing the software UHF Tag Manager to connect UE600. Please refer to UE600 Software User Guide. There are instructions about how to read/write tags. NOTE The performance might be better or worse according to different tags and working environments. UE600 can only read one tag at a time. Therefore, please keep other tags about 40cm away to reduce the interference. Do not put tags to or near metal objects or liquid surface as possible. Make sure there are not any same frequency devices or large power equipment in the same area. 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 4 UE600 User Guide Chapter 4Troubleshooting 1. Cannot connect to UE600 with UHF Tag Manager?
Please check the Power light of UE600 is lighting. Please check USB cable is connecting well to PC. 2 Cannot read UHF Tags?
Please check the software UHF Tag Manager can find out UE600 and connect to it. Please check the tag is a UHF tag and is functional. While you put a UHF tag on the top of UE600 and execute read command (or Auto) , the Read light shall light up once. 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 5 UE600 User Guide Contact us Address:
8F, NO.31, Lane 169, Kang-Ning Street, His-Chih Dist, New Taipei City, Taiwan Tel:
886-2-26954214 Fax:
886-2--26954213 Websites:
www.gigatms.com.tw Email:
Sales inquiry email - promag@gigatms.com.tw After sales service - support@gigatms.com.tw 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 6 TA500 User Guide TM951328 - 01 April 16, 2015 Copyright 2015 GIGA-TMS INC. Printed in Taiwan Any part of the contents of this document, without the express written GIGA-TMS permission, shall not in any documents, electronic, mechanical form of remakes or spread. File contents are subject to change without notice. Revisions Date Description April 16, 2015 preliminary draft Revision 01 Has been tested in accordance to essential protection requirements of the R&TTE Directive 1999/5/EC on the approximation of the laws of the Member States relating to Radio Spectrum Matters and found the test results indeed meet the limitation of the relevant test standard(s) listed below:
EMC Radio Spectrum Safety EN 301 489 - 1: V1.9.2 EN 302 208 - 2: V1.4.1 :
(2011) 2011 EN 301 489 - 3: V1.6.1 EN 302 208 - 1: V1.4.1 :
(2013) 2011 EN 60950-1:2006+A11:2009+A1:2010+
A12:2011+A2:2013 Test standard: FCC rules Part 15 subpart C 15.247 (2013 - 10) Test Result: No deviations from the technical specification(s) were ascertained in the course of the tests performed. Test standard: FCC rules Part 15 subpart B Test Result: Radiated Emission. FCC Part 15. 109 / 15.107 Class B. Test passed. Warning Federal Communication Commission (FCC) Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Contents Chapter 1Introduction...........................................................................1 Chapter 2About TA500 .........................................................................2 Specification........................................................................................................ 2 LED Indication ..................................................................................................... 3 Chapter 3How to Use TA500 ................................................................4 Before Installing .................................................................................................. 4 Start to Use TA500 .............................................................................................. 4 Chapter 4Troubleshooting ...................................................................5 Contact us..................................................................................................6 TA500 ser Guide Chapter 1Introduction Introduce The TA500 is a desktop Ultra High Frequency RFID Reader compliant to ISO18000-6C EPC Gen 2 protocol with an operating range of 840 to 960 MHz. As a smart UHF reader, TA500 also supports EPC Encoding and Decoding feature compatible with EPC Tag Data Standard (TDS) of GS1. And TA500 also easy to use USB HID to connect PC and have auto sensor which can auto read Tag. The software TA500 Tag Issuer is supplied with the reader for Tag reading and analysis. Before using the TA500 Reader. We recommend that you should already read this user guide. Fitting TA500 include antenna. The appearance as shown below TA500 Top view TA500 USB Interface Please download software or user guide from following link:
http://ftp.gigatms.com.tw/disks/disk5473/
60cm USB cable table 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 1 TA500 User Guide Chapter 2About TA500 Europe TA500-30 865~868 MHz USA TA500-00 Specification TA500 Standard RFID spec Frequency Range RF power Interface Power Require Standby : 110mA@5VDC Max 16dBm USB HID ISO 18000-6C, EPC Class1 Gen2 902~928 MHz RF Reading Range Dimension Physical Characteristics Weight Environment parameter Temperature Humidity Working : 300mA@5VDC, Min power require : 500mA@ 5VDC Max 20 cm (depending on Tag) L: 120mm / W: 86mm / H: 79mm 150g ( not Include USB cable ) Operating : -10C ~ 60C Storage : -15C ~ 65C Operating : 10% ~ 90% (no coagulation) Storage : Max 90% (no coagulation) Regulatory approvals Authentication CE R&TTE EN 302 208-1/-2 EN 301 489-1/-3 EN 60950-1 ESD Conduct : 6kv , Air : 8kv FCC ID PART 15B/C 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 2 TA500 User Guide LED Indication Status / Color Power ON Standby Read Success Read Fail Power / Red Read / Green Buzzer / Beep a beep OFF a beep 3 beeps ON OFF ON ON ON ON ON ON 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 3 TA500 User Guide Chapter 3How to Use TA500 Before Installing Before Install TA500. Please make sure the following items are ready. A computer (Window XP / Vista / 7 or higher version systems) which already installed UHF Tag Manager. A TA500 reader with USB cable. UHF Tags (ISO18000 Class 1 Gen 2). Start to Use TA500 Connecting TA500 on USB port of your PC. Executing the software UHF Tag Manager to connect TA500. Please refer to TA500 Software User Guide. There are instructions about how to read tags. NOTE The performance might be better or worse according to different tags and working environments. TA500 can only read one tag at a time. Therefore, please keep other tags about 40cm away to reduce the interference. Do not put tags to or near metal objects or liquid surface as possible. Make sure there are not any same frequency devices or large power equipment in the same area. 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 4 TA500 User Guide Chapter 4Troubleshooting 1. Cannot connect to TA500 with UHF Tag Manager?
Please check the Power light of TA500 is lighting. Please check USB cable is connecting well to PC. 2 Cannot read UHF Tags?
Please check the software UHF Tag Manager can find out TA500 and connect to it. Please check the tag is a UHF tag and is functional. While you put a UHF tag on the top of TA500 and execute read command (or Auto) , the Read light shall light up once. 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 5 TA500 User Guide Contact us Address:
8F, NO.31, Lane 169, Kang-Ning Street, His-Chih Dist, New Taipei City, Taiwan Tel:
886-2-26954214 Fax:
886-2--26954213 Websites:
www.gigatms.com.tw Email:
Sales inquiry email - promag@gigatms.com.tw After sales service - support@gigatms.com.tw 2015 GIGA-TMS Corporation. All rights reserved http://www.gigatms.com.tw 6