Outdoor Fixed Security Light with remote sensor MODEL:17000213 INTRODUCTION It contains a light and a sensor. The sensor incorporates a PIR (Passive Infra Red) sensing device which continuously scans a preset operating zone and immediately transmit a signal to the light to switches the light on when it detects movement in that area. This means that whenever movement is detected within the range of the sensor the light will switch on automatically to illuminate pathways, steps, patios, porches, or whatever area you have selected to light for reasons of safety, convenience or security. While there is movement within range of the unit the light will remain on. WHILE TO FIT YOUR LIGHT To achieve best results, we suggest you account points:
Ideally the Light should be mounted 1.8 to 2.5 meters (6 to 8ft) the following above the area to be scanned To avoid damage to unit-do not aim the sensor towards the sun. To avoid nuisance triggering, the sensor should be directed away from heat sources such as barbecues, Air-conditioners, other outside lighting, moving cars and flue vents. To avoid nuisance triggering, keeping away from the area of strong electromagnetic disturbance. Do not aim towards reflective surfaces such as smooth white walls, swimming pools, etc. The sensor scanning specifications
(Max. 15 meters at 240) may vary slightly depending on the mounting height and location. The detection range of the unit may also alter with temperature change. Before selecting a place to install your sensor you should note that movement across the scan area is more effective than movement directly toward or away from the sensor. (refer Figure). If movement is made walking directly towards or away from the sensor and not the apparent detection range will be substantially across, reduced. FITTING THE UNIT Installation by a licensed electrician and according to IEC wiring Regulation. commencing any Before electrical work, ensure mains supply cables are isolated by switching off and removing the relevant fuse. Mounting the Light:
1. Mounting the mounting support onto the Junction box 2. Connect the main cable to the terminal 3. Mounting the mounting panel onto the mounting support 4. Mounting the main light onto the mounting panel. 5. Switch the main power on. Mounting the Sensor:
emove the back cover 1. 2. Unscrew the battery cover screw 3. Remove the battery cover 4. Instilling two AA batteries into the battery box. Re-fit the battery cover onto the sensor 5. Use the back cover to mark the position of screw holes onto mounting surface. Drill the wall to depth of about 60 mm and fit the plastic plugs, and then fix the Cover to the mounting surface with rightly screws. Be careful to avoid drilling into concealed electrical wiring. screwing or 6. Mounting the back cover onto the wall 7. Mounting the sensor onto the back cover. IMPORTANT:
1. Never attempt to remove the lens cover as this will damage the sensor and render all guarantees invalid. 2. Before touching the light, please switch off first and then let it cool ProtectionClass after activation UNDERSTANDING THE CONTROLS (referring to the Figure) ADJUSTING THE ON TIME: The length of switched on TEST,1min,5min,20min . Note:
1. Once the light has been triggered by the PIR sensor any subsequent detection will start the timed period again from the beginning. TEST, the light will turn on about 5s whether day or night 1min,5min,20min:The light only turn on at night. time that remains between adjusted 2. 3. can be ADJUSTING THE DURATION SENS: The sensitivity means the Maximum distance which PIR Sensor can be triggered by movement body. Distribution network method:
Long press the switch, the indicator light will flash 5 times, and then release. The indicator light will flash every 1 second. At this time, the sensor enters the distribution mode, and the lights that have not been connected to the network will be powered on. The lights will remain on for 3 minutes when not distributed to the network, and will turn off after being distributed to the network. Press the switch again for 1 second, and the sensor will exit the distribution mode Cleaning network method: (Note: Even sensors that have not been connected to this light can be cleaned and re connected to this light) Turn off the light that needs to be cleaned, press the switch, and the indicator light will flash 10 times before releasing. The indicator light will remain on, and the sensor will enter the cleaning mode. Then, turn on the light that needs to be cleaned, and enter the cleaning mode. The successful cleaning light will flash 5 times every 1 second, and then enter the constant light mode for 3 minutes; Press the switch again for 1 second, and the sensor will exit the cleaning mode. If it is necessary to distribute the network for this lamp, it needs to be distributed according to the distribution network method within 3 minutes. TECHNICAL DETAILS :
LIGHT:
Voltage:108-132 VAC ~ 60Hz Wattage: 20W LED Lumen: 2200LM Color temperature:4000K Weatherproof: IP44 SENSOR:
Voltage: 2 AA 1.5V battery Detection range: 240 and Max. 15 meters Duration time: TEST,1min,5min,20min Weatherproof: IP44 ProtectionClass Suitable for indoor and outdoor use Company AUROLITE AUTOTECH GUANGDONG LTD Address No. 1 Jinsheng 1 Road, Hualong Town, Panyu District, Guangzhou, China This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modtifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. RF warning for Mobile device:
This equipment complies with FCC radiation exposure limits set forth for anuncontrolled environment. This equipment should be inst alled and operated with minimum distance 20cm between the radiator & your body. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil contient des metteurs / rcepteurs exempts de licence conformes aux RSS (RSS)d'Innovation, Sciences et Dveloppement conomique Canada. Le fonctionnement est soumis aux deux conditions suivantes :
(1) Cet appareil ne doit pas causer d'interfrences.
(2) Cet appareil doit accepter toutes les interfrences, y compris celles susceptibles de provoquer un fonctionnement indsirable de l'appareil. avertissements radio pour les appareils portables :
L' quipement a t valu et satisfait aux exigences gnrales d'exposition par radiofrquence. L'appareil peut tre utilis sans restriction dans des conditions d'exposition portables. FCC Responsible Party Name:Globe Electric Company Inc. Address: 150 Av. Oneida, Pointe-Claire, QC H9R 1A8 Canada Telephone Number: (514) 694-0444 CAN ICES-005 (B)/NMB-005 (B)