Version 0.1 Date May 11, 2018 Page 1/ 42 Title USER MANUAL Prepared by Reviewed by Approved by USER MANUAL EZD-LICPA23 EZS-LICPA30 May 11, 2018 GS Instech Co., Ltd. 2018 GS Instech Co., Ltd. All rights reserved. 1 Version 0.1 Date May 11, 2018 Page 2/ 42 Title USER MANUAL Prepared by Reviewed by Approved by
[CHANGE RECORD]
DATE NAMES DESCRIPTIONS VERSION REMARK May 11, 2018 H.J.CHOI Original Draft 0.1 2018 GS Instech Co., Ltd. All rights reserved. 2 Version 0.1 Date May 11, 2018 Page 3/ 42 Title USER MANUAL Prepared by Reviewed by Approved by
[TABLE OF CONTENTS]
CHAPTERs INDEX 1. GENERAL ............................................................................. 7 1.1. Purpose ............................................................................................. 7 1.2. Copyright ........................................................................................... 7 1.3. FCC Warning Statements .......................................................................... 8 2. INTRODUCTION .................................................................... 11 2.1. System Overview ................................................................................. 11 2.2. Main Features .................................................................................... 12 3. SYSTEM DESIGN FOR EZD-LICPA23 (DONOR UNIT) ............................... 13 3.1. Exterior View ...................................................................................... 13 3.2. Interior View ...................................................................................... 14 3.3. External Interface ................................................................................. 15 3.4. FCC Statement ..................................................................................... 16 4. SYSTEM DESIGN FOR EZS-LICPA30 (SERVICE UNIT) ............................... 17 4.1. Exterior View ..................................................................................... 17 4.2. Interior View ...................................................................................... 18 4.3. External Interface ................................................................................ 19 4.4. FCC Statement .................................................................................... 20 2018 GS Instech Co., Ltd. All rights reserved. 3 Version 0.1 Date May 11, 2018 Page 4/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 5. SYSTEM SPECIFICATION ............................................................ 21 5.1. RF Performance................................................................................... 21 5.2. Frequency Information ........................................................................... 23 5.2.1. 700MHz ..................................................................................................................................................................................................... 23 5.2.2. 800/850MHz ............................................................................................................................................................................................ 24 5.2.3. 1900MHz ................................................................................................................................................................................................... 25 5.2.4. 2100MHz ................................................................................................................................................................................................... 26 5.3. Configuration & Mechanical Specification ..................................................... 27 6. SYSTEM BLOCK CONFIGURATION ................................................. 28 6.1. Block Diagram .................................................................................... 28 7. GUI OVERVIEW ..................................................................... 30 7.1. Configuration the Laptop to Connect to the Repeater .......................................... 30 7.2. Login-In Screen .................................................................................... 31 7.3. Main Screen ...................................................................................... 32 7.4. RF Status .......................................................................................... 33 7.5. RF Configuration .................................................................................. 34 7.6. Band Selection .................................................................................... 35 8. SYSTEM INSTALLATION ............................................................ 36 8.1. Warnings and Hazards ............................................................................ 37 8.1.1. Electric Shock ........................................................................................................................................................................................... 37 8.1.2. Exposure to RF ......................................................................................................................................................................................... 37 8.2. Service Man Installation Guide ................................................................. 38 8.2.1. Wall Mount Installation ......................................................................................................................................................................... 38 4 2018 GS Instech Co., Ltd. All rights reserved. Version 0.1 Date May 11, 2018 Page 5/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 8.3. Cable Connection ................................................................................. 40 8.3.1. AC Power cable connection .................................................................................................................................................................. 40 8.3.2. Local Maintenance Connection ........................................................................................................................................................... 41 8.3.3. Grounding cable Connection ............................................................................................................................................................... 41 FIGUREs INDEX FIGURE 1.FCC/ UL CERTIFICATION STATEMENT ......................................................................................................................................................... 8 FIGURE 2.EZ-DAS APPLICATION CONFIGURATIONS ............................................................................................................................................... 11 FIGURE 3. EZD-LICPA23 EXTERIOR VIEW .................................................................................................................................................................. 13 FIGURE 4. EZD-LICPA23 INTERIOR VIEW .................................................................................................................................................................. 14 FIGURE 5. EZD-LICPA23 EXTERNAL INTERFACE ....................................................................................................................................................... 15 FIGURE 6. EZD-LICPA23 UNIT FCC STATEMENT ....................................................................................................................................................... 16 FIGURE 6. EZS-LICPA30 EXTERIOR VIEW ................................................................................................................................................................... 17 FIGURE 7. EZS-LICPA30 INTERIOR VIEW ................................................................................................................................................................... 18 FIGURE 9. EZS-LICPA30 EXTERNAL INTERFACE........................................................................................................................................................ 19 FIGURE 10. EZS-LICPA30 UNIT FCC STATEMENT ..................................................................................................................................................... 20 FIGURE 11. EZD-LICPA23 BLOCK DIAGRAM CONFIGURATION ............................................................................................................................ 28 FIGURE 12. EZS-LICPA30 BLOCK DIAGRAM CONFIGURATION ............................................................................................................................. 29 FIGURE 13. THE WAY TO FIX THE BRACKET ON THE POLE (NORMAL TYPE) .................................................................................................... 38 FIGURE 14. THE WAY TO FIX FIRMLY THE SYSTEM FOR POLE MOUNTING ...................................................................................................... 39 TABLEs INDEX TABLE 1. EZD-LICPA23 UNIT CONFIGURATION ........................................................................................................................................................ 14 TABLE 2. EZD-LICPA23 EXTERNAL INTERFACE DESCRIPTION ............................................................................................................................... 15 TABLE 3. EZS-LICPA30 UNIT CONFIGURATION ......................................................................................................................................................... 18 TABLE 4. EZS-LICPA30 EXTERNAL INTERFACE DESCRIPTION ................................................................................................................................ 19 TABLE 5. EZ-DAS RF PERFORMANCE DESCRIPTION ............................................................................................................................................... 22 TABLE 6. EZ-DAS 700MHZ OPERATING FREQUENCY INFORMATION ................................................................................................................. 23 TABLE 7. EZ-DAS 800/850MHZ OPERATING FREQUENCY INFORMATION FOR CDMA .................................................................................. 24 TABLE 8. EZ-DAS 800/850MHZ OPERATING FREQUENCY INFORMATION FOR LTE ........................................................................................ 24 TABLE 9. EZ-DAS 1900MHZ OPERATING FREQUENCY INFORMATION FOR CDMA ......................................................................................... 25 TABLE 10. EZ-DAS 1900MHZ OPERATING FREQUENCY INFORMATION FOR LTE ............................................................................................ 25 5 2018 GS Instech Co., Ltd. All rights reserved. Version 0.1 Date May 11, 2018 Page 6/ 42 Prepared by Reviewed by Approved by Title USER MANUAL TABLE 11. EZ-DAS 2100MHZ OPERATING FREQUENCY INFORMATION ............................................................................................................ 26 TABLE 12. EZ-DAS CONFIGURATION & MECHANICAL SPECIFICATION............................................................................................................... 27 TABLE 13. EZ-DAS INSTALLATION ACCESSORIES...................................................................................................................................................... 36 2018 GS Instech Co., Ltd. All rights reserved. 6 Version 0.1 Date May 11, 2018 Page 7/ 42 Prepared by Reviewed by Approved by Title USER MANUAL 1. General 1.1. Purpose This document introduces features, specifications, structures and operation guideline for the EZD-LICPA23/ EZS-LICPA30. 1.2. Copyright All text and image in this document are subject to the copyright of GS Instech Co., Ltd. This document may not be reproduced, distributed, or modified without the written permission of GS Instech Co., Ltd. 2018 GS Instech Co., Ltd. All rights reserved. 7 Version 0.1 Date May 11, 2018 Page 8/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 1.3. FCC Warning Statements FCC Warning Statement for system is follows. Must attach the label under manufacturing. Figure 1.FCC/ UL Certification Statement 2018 GS Instech Co., Ltd. All rights reserved. 8 Version 0.1 Date May 11, 2018 Page 9/ 42 Prepared by Reviewed by Approved by Title USER MANUAL FCC Part 15.105 statement (Class A) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Part 15.21 statement Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Home/ personal use are prohibited Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indooronly restrictions is prohibited 2018 GS Instech Co., Ltd. All rights reserved. 9 Version 0.1 Date May 11, 2018 Page 10/ 42 Title USER MANUAL RF Radiation Exposure Prepared by Reviewed by Approved by This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. Antenna installation Antennas must be installed in accordance with FCC 27.50, 24. The height of the antenna above average terrain (HAAT) must not exceed limit in the following table. Type Model name(s) EZ-DASS-L37 EZ-DASS-L30 EZ-DASS-IC37 EZ-DASS-IC30 EZ-DASS-P37 EZ-DASS-P30 EZ-DASS-A39 EZ-DASS-A32 EZ-DASD-L23 EZ-DASD-IC23 EZ-DASD-P23 EZ-DASD-A23 SU DU HAAT (m) 11 337.60 25 313.42 4 293.78 9 534.59 2 749.43 6 135.58 5 725.41 13 003.80 14 408.20 5 360.99 3 799.80 10 151.20 Antenna again 3dBi 3dBi 3dBi 3dBi 7dBi 7dBi 7dBi 7dBi 15dBi 15dBi 18dBi 18dBi WARNING. THIS is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licenses to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. 2018 GS Instech Co., Ltd. All rights reserved. 10 Version 0.1 Date May 11, 2018 Page 11/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 2. Introduction 2.1. System Overview EZ-DAS is designed to improve coverage and capacity of Commercial Quad Band. Either feeding Carrier BTS signal directly or receiving signal via antenna, it provides coverage Building in RF shadow. Figure 2.EZ-DAS Application Configurations 2018 GS Instech Co., Ltd. All rights reserved. 11 Version 0.1 Date May 11, 2018 Page 12/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 2.2. Main Features All-in One Donor Unit
- Compose several units such as Optic Transceiver, NMS, PSU, BDA, Cavity Filter etc.
- Convenient to install in Middle Size Building with proper cost of one set Support the BTS or Antenna Feeding Solution
- Either feeding Carrier BTS Signal directly or receiving signal via Antenna
- With built-in BDA(Bi-Directional Amplifier) function, it is possible to use under Antenna feeding condition Choose the Filtering Methods accord to the operating condition
-
For Neutral Host installations, able to support the Full Band Filtering Improving Service Quality under Multi-Carriers Area
- Up to 6 Non-Contiguous block and gain per block based on Downlink Input Topologies
- Dealing with Near-far & Uplink Noise Floor Rise Topologies
- 1:4 Branches between Donor Unit and Service Unit.
- 3 Daisy Chain is possible with Daisy Chain Optic Unit. Supporting Technologies
- CDMA, LTE Supporting Frequencies
- Commercial Quad band (700M, 800+850M, 1900M, 2100M) Supporting Output Power
- Composite 4W with EZ-DASS-LICPA 30 (1W per Band)
- Composite 20W with EZ-DASS-LICPA 37 (5W per Band) Functions
-
Support AGC, ALC, AGA with LLA(Low Limit ALC), ASD FCC Part 22, 24,27,90 & Part 15B class A 2018 GS Instech Co., Ltd. All rights reserved. 12 Version 0.1 Date May 11, 2018 Page 13/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 3. System Design for EZD-LICPA23 (Donor Unit) 3.1. Exterior View Figure 3. EZD-LICPA23 Exterior View 13 2018 GS Instech Co., Ltd. All rights reserved. Version 0.1 Date May 11, 2018 Page 14/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 3.2. Interior View No Name Remark Figure 4. EZD-LICPA23 Interior View 1 2 3 4 5 6 7 8 9 EZ-DASD-IC23 800/850MHz RF Digital Filter Unit EZ-DASD-P23 1900MHz RF Digital Filter Unit EZ-DASD-L23 700MHz RF Digital Filter Unit EZ-DASD-A23 2100MHz RF Digital Filter Unit Cavity Filter Quadplexer for 800/850M & 1900M/ 700M+2100M Band Combiner Cavity Filter Quadplexer for 700M & 2100M PSU DOU AC Input Voltage: 110VAC~240VAC(60Hz)/ DC Output Voltage: +6V Donor Optic Unit (4Port) RCDU-5W 5Way RF Channel Distribute Unit 10 SNMP Board Apply for Web-UI/ Communicate with Service Unit Table 1. EZD-LICPA23 Unit Configuration 14 2018 GS Instech Co., Ltd. All rights reserved. Version 0.1 Date May 11, 2018 Page 15/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 3.3. External Interface Figure 5. EZD-LICPA23 External Interface No NAMES DESCRIPTION SPECIFICATION 1 2 3 4 5 6 7 8 ANT AC IN Feeding Downlink Signal
/ Transmit Uplink Output 4.3-10 Din Connector AC Input Outlet MS3102A 22-2 OPTIC0~3 Insert the optic cable to Service Unit Metal Cable Gland EDU RF DL Receive a Downlink RF Signal from EDU (Wire only) EDU RF UL Transmit a uplink RF Signal to EDU (Wire only) Communicate a data between MDU & EDU or Server SMA(F) SMA(F) RJ-45 System Total Alarm Indication General Performance LAN LED Vent-Core Maintain Humidity & Temp Inside IP66 Table 2. EZD-LICPA23 External Interface Description 15 2018 GS Instech Co., Ltd. All rights reserved. Version 0.1 Date May 11, 2018 Page 16/ 42 Title USER MANUAL 3.4. FCC Statement Prepared by Reviewed by Approved by Figure 6. EZD-LICPA23 UNIT FCC Statement 2018 GS Instech Co., Ltd. All rights reserved. 16 Version 0.1 Date May 11, 2018 Page 17/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 4. System Design for EZS-LICPA30 (Service Unit) 4.1. Exterior View Figure 7. EZS-LICPA30 Exterior View 2018 GS Instech Co., Ltd. All rights reserved. 17 Version 0.1 Date May 11, 2018 Page 18/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 4.2. Interior View No Name Remark Figure 8. EZS-LICPA30 Interior View 1 2 3 4 5 6 7 8 9 10 11 EZ-DASS-IC30 800/850MHz RF Power Amp Unit EZ-DASS-P30 1900MHz RF Power Amp Unit EZ-DASS-L30 700MHz RF Power Amp Unit EZ-DASS-A32 2100MHz RF Power Amp Unit Cavity Filter Quadplexer for 800/850M & 1900M/ 700M+2100M Band Combiner Cavity Filter Quadplexer for 700M & 2100M PSU SOU AC Input Voltage: 110VAC~240VAC(60Hz)/ DC Output Voltage: +6V/ +29V Service Optic Unit RCDU-4W 4Way RF Channel Distribute Unit NMS Board Apply for GUI/ Communicate with Donor Unit DCO Daisy Chain Optic Unit/ For SU Cascade Application Table 3. EZS-LICPA30 Unit Configuration 18 2018 GS Instech Co., Ltd. All rights reserved. Version 0.1 Date May 11, 2018 Page 19/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 4.3. External Interface Figure 9. EZS-LICPA30 External Interface No NAMES DESCRIPTION SPECIFICATION 1 2 3 4 5 6 ANT AC IN OPTIC0 OPTIC1 LED Feeding Uplink Signal
/ Transmit Downlink Output 4.3-10 Din Connector AC Input Outlet MS3102A 22-2 Insert the optic cable to Donor Unit Metal Cable Gland Insert the optic cable to Next SU for Daisy Chain Metal Cable Gland System Total Alarm Indication General Performance Vent-Core Maintain Humidity & Temp Inside IP66 Table 4. EZS-LICPA30 External Interface Description 2018 GS Instech Co., Ltd. All rights reserved. 19 Version 0.1 Date May 11, 2018 Page 20/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 4.4. FCC Statement Figure 10. EZS-LICPA30 UNIT FCC Statement 20 2018 GS Instech Co., Ltd. All rights reserved. Version 0.1 Date May 11, 2018 Page 21/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 5. System Specification 5.1. RF Performance Parameter Down Link Up Link Remark 728MHz~756MHz 698MHz~716MHz/ 777MHz~787MHz 700MHz 862MHz~894MHz 817MHz~849MHz 800/850MHz Frequency Range 1930MHz~1995MHz 1850MHz~1915MHz 2110MHz~2180MHz 1710MHz~1755MHz Input Range
-60dBm ~ -30dBm/ Total
-67dBm Output Power
+30dBm with EZS-LICPA30
+30dBm with EZS-LICPA30
+30dBm with EZS-LICPA30
+32dBm with EZS-LICPA30
+23dBm(0.2W) With EZD-LICPA23 CDMA 15MHz max/ 1.25MHz Step Channel Capacity LTE 5M, 10M, 20M Range 50dB ~ 90dB with EZS-LICPA30 Gain Adjust Step Accuracy Ripple Roll off Rho EVM 1dB 1dB 4dB p-p
> 50dBc @ Channel OBW 1MHz 0.912 (Rho) For CDMA
< 4% for 256QAM
< 4% for 64QAM For LTE 2018 GS Instech Co., Ltd. All rights reserved. 21 1900MHz 2100MHz Per Band 700M 800/850MHz 1900M 2100M ALC, AGC Included Version 0.1 Date May 11, 2018 Page 22/ 42 Prepared by Reviewed by Approved by Title USER MANUAL Parameter Down Link Up Link
< 0.05ppm
< 5us Less than 6dB @ Min & Max Gain
< 1.5 : 1
<-5.5dBm @50KHz f < 5.05MHz (RBW: 100KHz) Remark Exclude Fiber Optic Delay Only UL Frequency Error System Delay Noise Figure VSWR OB Unwanted Emission
<-12.5dBm @5.05MHz f < 10.05MHz (RBW: 100KHz) For LTE
<-13dBm @10.5MHz f < 15MHz (RBW: 1MHz) ACLR
> 45dBc @ 5MHz, 10MHz, 20MHz, 40MHz For LTE 885 kHz
-45dBc with a 30KHz RBW Pout > 33dBm; -55dBc with a 30KHz RBW 1.98 MHz 28dBm Pout<33dBm; -22dBm with a 30KHz RBW Spurious Emission 2.25 MHz
-13dBm with a 30KHz RBW For CDMA
-13dBm / 1 kHz: 9 kHz < f < 150 kHz 4.0 MHz
-13dBm / 10 kHz: 150 kHz < f < 30 MHz
-13dBm/100 kHz: 30 MHz < f < 1 GHz ITU category A
-13dBm / 1 MHz: 1 GHz < f < 12.75 GHz Table 5. EZ-DAS RF Performance Description 2018 GS Instech Co., Ltd. All rights reserved. 22 Version 0.1 Date May 11, 2018 Page 23/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 5.2. Frequency Information 5.2.1. 700MHz Transmit frequency band (MHz) Uplink Downlink 698 777 716 787 728 746 746 756 Bandwidth UL / DL 18 (Lower C) 10 (Upper C) Table 6. EZ-DAS 700MHz Operating Frequency Information
[LTE]
Block LTE 10M 2018 GS Instech Co., Ltd. All rights reserved. 23 Version 0.1 Date May 11, 2018 Page 24/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 5.2.2. 800/850MHz
[CDMA]
Block A1 B1 A2 B2 Block Transmit frequency band (MHz) Uplink Downlink Bandwidth UL / DL 824 835 845 846.5 835 845 846.5 849 869 880 890 891.5 880 890 891.5 894 11 10 1.5 2.5 Table 7. EZ-DAS 800/850MHz Operating Frequency Information for CDMA Transmit frequency band (MHz) Uplink Downlink Bandwidth UL / DL LTE 5M 817 849 862 894 32 Table 8. EZ-DAS 800/850MHz Operating Frequency Information for LTE
[LTE]
2018 GS Instech Co., Ltd. All rights reserved. 24 Version 0.1 Date May 11, 2018 Page 25/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 5.2.3. 1900MHz
[CDMA]
Block A D B E F C
[LTE]
Block Transmit frequency band (MHz) Uplink Downlink Bandwidth UL / DL 1850 1865 1870 1885 1890 1895 1865 1870 1885 1890 1895 1910 1930 1945 1950 1965 1970 1975 1945 1950 1965 1970 1975 1990 15 5 15 5 5 15 Table 9. EZ-DAS 1900MHz Operating Frequency Information for CDMA Transmit frequency band (MHz) Uplink Downlink Bandwidth UL / DL LTE 20M 1850 1915 1930 1995 65 Table 10. EZ-DAS 1900MHz Operating Frequency Information for LTE 2018 GS Instech Co., Ltd. All rights reserved. 25 Version 0.1 Date May 11, 2018 Page 26/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 5.2.4. 2100MHz
[LTE]
Block Transmit frequency band (MHz) Downlink Uplink Bandwidth UL / DL LTE 10M 2110 2180 1710 1755 45M/ 70M Table 11. EZ-DAS 2100MHz Operating Frequency Information 2018 GS Instech Co., Ltd. All rights reserved. 26 Version 0.1 Date May 11, 2018 Page 27/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 5.3. Configuration & Mechanical Specification Parameter Donor/ Service Antenna Filter Specification Remark QUADPLEXER+BAND COMBINER One port In/Output AC Input Voltage: 110VAC~240VAC(60Hz) Power Supply DC Output Voltage: +6V DC Output Voltage: +6V/ +29V Operation Temperature
-10C~+50C (100%RH) Storage Temperature
-10C~+80C (5~95%RH) Antenna: 4.3-10 DIN Female AC: MS-3102A 22-2 Optic Connection: Metal Cable Gland Free Voltage EZD-LICPA23 EZS-LICPA30 EZD-LICPA23 EZS-LICPA30 Connectors Cable Size Weigh Power Consumption Environment MTBF EDU Connection: SMA Female(RF)/ MS3102A18-8(DATA) EZD-LICPA23 1/2" Plenum-Rated Air-Dielectric Coaxial Cable 13.78" x 21.6" x 12.2" without Bracket 13.78" x 21.6" x 10.3" without Bracket Less than 42kg (92.5lb) without Bracket Less than 40kg (88.1lb) without Bracket Less than 200W Less than 250W IP54 100,000 hours or higher EZD-LICPA23 EZS-LICPA30 EZD-LICPA23 EZS-LICPA30 EZD-LICPA23 EZS-LICPA30 Grounding nonferrous metal and anchoring point on bottom side For RF and power cabling Mount Application Wall Mount Table 12. EZ-DAS Configuration & Mechanical Specification 2018 GS Instech Co., Ltd. All rights reserved. 27 Version 0.1 Date May 11, 2018 Page 28/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 6. System Block Configuration 6.1. Block Diagram Figure 11. EZD-LICPA23 Block Diagram Configuration The repeater improves service in the commercial Quad-Band. User may select frequency band according to the site peculiarities. After receiving a weak signal from Donor antenna or BTS directly, the EZD-LICPA23 sends downlink signal to EZS-
LICPA30 using DOU (Donor Optic Unit). DOU supports the translation of RF signal to Optic signal for connecting EZS-LICPA30 through the fiber optic cable. And then Uplink Signal that received from EZS-LICPA30 amplify, is send to the Base station via Donor Antenna or is connected to BTS directly. In other words, EZD-LICPA23 is only transmitting the Uplink Signal over the air. 2018 GS Instech Co., Ltd. All rights reserved. 28 Version 0.1 Date May 11, 2018 Page 29/ 42 Prepared by Reviewed by Approved by Title USER MANUAL Figure 12. EZS-LICPA30 Block Diagram Configuration EZS-LICPA30 is operating very similar to the EZD-LICPA23 After receiving an Uplink Signal from service antenna, the EZ-DASD-LICPA30 sends Uplink signal to EZD-LICPA23 using SOU (Service Optic Unit). SOU supports the translation of RF signal to Optic signal for connecting EZD-LICPA23 through the fiber optic cable. And then Down Signal that received from EZD-LICPA23 amplify, is send to the Mobile station via Service Antenna. In other words, EZD-LICPA23 is only transmitting the Uplink Signal over the air. 2018 GS Instech Co., Ltd. All rights reserved. 29 Version 0.1 Date May 11, 2018 Page 30/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 7. GUI Overview Provide all functions that can be performed at Service Unit will be available thru the Donor Unit. Support the GUI pages that will be addressable via UDP Interface. 7.1. Configuration the Laptop to Connect to the Repeater Connect an Ethernet crossover cable from the LAN port of the repeaters bottom side to your laptop 1. Go to Local Connection 2. Click on "Properties"
3. Highlight "Internet Protocol"
4. Click on "Properties"
5. Choose "Obtain DNS Server address automatically"
6. Clink OK 2018 GS Instech Co., Ltd. All rights reserved. 30 Version 0.1 Date May 11, 2018 Page 31/ 42 Title USER MANUAL 7.2. Login-In Screen GUI Screen for Log-In Prepared by Reviewed by Approved by Enter the IP Address "192.168.1.1" and Port into GUI Main Screen. And then Connect. 2018 GS Instech Co., Ltd. All rights reserved. 31 Version 0.1 Date May 11, 2018 Page 32/ 42 Title USER MANUAL 7.3. Main Screen GUI Screen for Main Menu Prepared by Reviewed by Approved by Able to select system that user control, Configuration & Status monitoring Green means that the system is operating under normal condition. Red means that the system is operating under abnormal condition. In other words, system is likely non-working. Gray means that the system is not linked or communicated fail. But if it is not communicated between DU and SU, Donor Unit is also changed Red. 2018 GS Instech Co., Ltd. All rights reserved. 32 Version 0.1 Date May 11, 2018 Page 33/ 42 Prepared by Reviewed by Approved by Title USER MANUAL 7.4. RF Status GUI Screen for display Repeaters RF Status 2018 GS Instech Co., Ltd. All rights reserved. 33 Version 0.1 Date May 11, 2018 Page 34/ 42 Prepared by Reviewed by Approved by Title USER MANUAL 7.5. RF Configuration GUI Screen in order to change the RF values User may change the various RF values of the repeater on this page Changes will not take effect until you click "Apply" button This menu is where the installer will choose references for specific implementation 2018 GS Instech Co., Ltd. All rights reserved. 34 Version 0.1 Date May 11, 2018 Page 35/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 7.6. Band Selection Repeater support the capacity of CDMA and LTE Technologies Ability to set the 6 Non-Contiguous channel Support the CDMA 15MHz max per 1.25 step and LTE 5MHz, 10MHz, 20MHz User can set the desired channel using the GUI Write the Fc or EARFCN 2018 GS Instech Co., Ltd. All rights reserved. 35 Version 0.1 Date May 11, 2018 Page 36/ 42 Prepared by Reviewed by Approved by Title USER MANUAL 8. System Installation This chapter describes how to install the repeater and Cabling method The needed accessories and tools are list up as below
#
1 2 3 Contents Mounting Bracket AC Power Cable SJT 3/16 AWG, 6ft Frame Ground Cable with Tubular Cable Lug, 6ft EYE BOLT(M12) 4 Installation purchase set M5x12mm WRENCH BOLT, SEMS PH(+) M4x8mm ,SEMS LAG SCREW 3/8x3 HEX HEAD 3/8x2, SCM440 Picture Qty 1EA 1EA 1EA 1EA 2EA 4EA 2EA 2EA 5 Mounting Screw set 10.5mm/21mm PLAIN WASHER 2EA 10.2mm/18.4mm SPRING WASHER 6 Tubing Tube Sleeve Black 30mm/L:150mm Adhesive Polyolefin 3:1 Heat Shrink Table 13. EZ-DAS Installation Accessories 2018 GS Instech Co., Ltd. All rights reserved. 36 2EA 1EA Version 0.1 Date May 11, 2018 Page 37/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 8.1. Warnings and Hazards 8.1.1. Electric Shock Opening the Repeater could result in electrical shock and may cause severe injury Operating the Repeater with antennas in very close proximity facing each other could lead to severe damage to the repeater 8.1.2. Exposure to RF Working with the repeater while in operation, may expose the technician to RF electromagnetic fields that exceed FCC Rules for human expose. Visit the FCC Website at http://www.fcc.gov/oet/rfsafety to learn more about The effects of exposure to RF electromagnetic fields 2018 GS Instech Co., Ltd. All rights reserved. 37 Version 0.1 Date May 11, 2018 Page 38/ 42 Title USER MANUAL Prepared by Reviewed by Approved by 8.2. Service Man Installation Guide 8.2.1. Wall Mount Installation The procedure for fixing the pole type system is as follows. Service man is mounting the same way the EZD-LICPA23 and EZS-LICPA30. 1) To mount the system on the wall, first fix the bracket on the wanted position. 2) Hang the system to the hooking position at the top of the mounting bracket 3) Push the system to the hooking position at the bottom of the mounting bracket. 10.5mm/21mm PLAIN WASHER 10.2mm/18.4mm SPRING WASHER LAG SCREW 3/8"x3"
Figure 13. The way to fix the bracket on the pole (Normal type) Protection gloves and goggles Make sure that worker wears protection gloves and goggles to prevent damages from debris while drilling holes in a Pole or Wall 2018 GS Instech Co., Ltd. All rights reserved. 38 Version 0.1 Date May 11, 2018 Page 39/ 42 Title USER MANUAL Prepared by Reviewed by Approved by Cautions while drilling on the pole Drilling thru-hole on a center of the pole 4) Align the system with the fixing holes of the mounting bracket and fix them firmly M5x12mm WRENCH BOLT, SEMS Figure 14. The way to fix firmly the System for Pole Mounting Cautions System leveling Before fixing the system, Check the horizontal and vertical level using a spirit level 2018 GS Instech Co., Ltd. All rights reserved. 39 Version 0.1 Date May 11, 2018 Page 40/ 42 Title USER MANUAL 8.3. Cable Connection Prepared by Reviewed by Approved by 8.3.1. AC Power cable connection Repeater supports a free AC Input voltage from 110V to 240V Provided Power cable is single type, so it can be used flexibly The pin description of AC Port is below. User should connect exact polarity of AC Port Outlook
(System Side) Port numbering for MS NAME Description A B C AC_H AC_N F.G AC Hot AC Neutral Frame Ground MS-3102A-10SL-3P The specification & Connection of AC Power Cable A A
- A: MS3106A-22-2
- Connect Port A for inserting AC Power 40 A 2018 GS Instech Co., Ltd. All rights reserved. Version 0.1 Date May 11, 2018 Page 41/ 42 Prepared by Reviewed by Approved by Title USER MANUAL 8.3.2. Local Maintenance Connection Repeater Support a RJ-45 connector 8.3.3. Grounding cable Connection Frame(Earth) Wire size is AWG #6. The way to install the grounding cable is below The specification of ground terminal lug is like below (Refer to JOCT 0202-RL05) Frame Ground 2018 GS Instech Co., Ltd. All rights reserved. 41 Version 0.1 Date May 11, 2018 Page 42/ 42 Prepared by Reviewed by Approved by Title USER MANUAL 2018 GS Instech Co., Ltd. All rights reserved. 42