FCC ID : U88GSTR-815DC-SPR ATTACHMENT C.
- USER MANUAL -
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No. : HCT-R07-031 1/1 SPRINT User Manual iDEN_15dBm May, 2007
- INDEX -
SPRINT User Manual iDEN 30dBm 1. SUMMARY ....................................................................................................3 2. SYSTEM CONFIGURATION ...........................................................................4 2.1 iDEN 800/900 SERVICE NETWORK CONFIFURATION ........................................................ 4 2.2 SYSTEM DESIGN AND OPERATION ..................................................................................... 5 3. SPECIFICATIONS .......................................................................................10 3.1 SYSTEM SPECIFICATIONS.................................................................................................10 3.2 MECHANICAL, ELECTRIC & ENVIRONMENTAL SPECIFICATIONS .....................................11 3.3 FUNCTIONS .......................................................................................................................11 4. SET UP........................................................................................................13 4.1 SYSTEM SET UP .................................................................................................................13 4.2 TROUBLESHOOTING..........................................................................................................16 5. WEB USER INTERFACE...............................................................................17 5.1 IP Address Verification & Explorer set up .........................................................................17 5.2 Connecting to Web UI .......................................................................................................19 5.3 Web UI ..............................................................................................................................19 2 1. SUMMARY SPRINT User Manual iDEN 30dBm iDEN repeater is located in blanket / shadow area of insider of building to transmit iDEN800MHz, iDEN900MHz BTS signal simultaneously. There are two types of RF Repeater for iDEN band as each 15dBm, and 25dBm output power in system 65dB Gain, and 30dBm output power in system 80dB Gain. This User Manual is the Repeater having 80dBGain / +15dBm output power. Bandwidth
- Downlink 851MHz~869MHz, Uplink 806MHz~824MHz (18MHz Band)
- Downlink 862MHz~869MHz, Uplink 817MHz~824MHz (7MHz Band) To avoid paging signal interference at 940MHz side, IF Converter shift SAW filter edge by 200KHz, 400KHz. (TX Edge only, not whole bandwidth). Also, This Repeater is equipped for Output power control by AGC/ALC, Gain Control by Attenuator adjustment, Remote Control by using Web UI and Remote Firmware Up-grade. Abbreviation PAM: POWER AMPLIFIER MODULE LNA: LOW NOISE AMPLIFIER AGC: AUTO GAIN CONTROL ALC: AUTO LIMIT CONTROL Ethernet Instruction This equipment is indoor use and all the communication wirings are limited to inside of the building or similar texts. For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible. Replaceable batteries instruction CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECTIVE TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS 3 SPRINT User Manual iDEN 30dBm 2. SYSTEM STRUCTURE 2.1 Network structure for iDEN 15dBm RF Repeater Below picture shows a Network structure for iDEN In-building RF Repeater in a real site. Donor ANT takes a position on the direction to BTS which be linked, and Server ANT is available to be located in designated area for service by using RF cable deployments and dividers as blow. One thing that we consider is Path losses between Repeater port and ANT in case of dividing by dividers and RF cables. They should be equally managed.
<Pic.1> iDEN In-building Repeater Service Organization 4 2.2 System Design and Operation 2.2.1 System design SPRINT User Manual iDEN 30dBm NO. PART PSU MODULE CAVITY FILTER MODULE CAVITY FILTER MODULE NMS MODULE NO. PART IO BOARD MODULE WAVE MONITORING MODULE RVS PATH PART FWD PATH PART
<Pic.2> iDEN 15dBm internal design 5 SPRINT User Manual iDEN 30dBm NO. PORT SERVER ANT PORT DONOR ANT PORT MONITOR PORT AC POWER PORT NO. PART DC POWER PORT CONTROL PORT ETHERNET PORT 2.2.2 Downlink Path
<Pic.3> iDEN 15dBm PORT design There are four (4) parts of downlink Block in iDEN In-building RF Repeater.
- Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX in Front End of Donor/Server
LNA part of Donor/Service path to process signals of 800MHz and 900MHz bands. If Converter part having several bands of SAW Filter paths to adjust Band Edge of high frequency as 200KHz and 400KHz each. In case of 800MHz band, extra Switching Filters equipped to individually select 18MHz and 7MHz 6 SPRINT User Manual iDEN 30dBm
- Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to adjust desirable output power of Repeater Downlink frequency contains lots of signals such as Paging signal, DCS etc through Donor ANT. So Out band signals should be minimized by SAW filters having excellent Roll off characteristics for the best optimized operation.
<Pic.4> iDEN In-building RF Repeater Downlink Block Diagram 2.2.3 Uplink Path Uplink Block of iDEN In-building RF Repeater is separated as four (4) parts.
- Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX in Front End of Donor/Server
LNA Part of two(2) paths for processing 800MHz and 900MHz signals
- 800MHz IF Converter part and 900MHz IF Converter part of 5MHz band having Switching filter parts for selecting each 18MHz and 7MHz. 7 SPRINT User Manual iDEN 30dBm
- Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to adjust desirable output power of Repeater 800MHz IF Converter part is designed to select single path, and it can be minimizing signal interference between paths, and power consumption according to controls of electric power in each SAW Filter part.
<Pic.5> iDEN In-building RF Repeater Uplink Block Diagram 2.2.4 Adjustable Band Edge functional circuit configuration In case of IDEN using the bandwidth of 800MHz and 900MHz, many of Out of Band Signals is input via Donor ANT Outdoor. The most worried signal among them is Paging Signal. Commercial Paging Signal of 929MHz~932MHz, 940MHz~941MHz, having the strength of Max.
-15dBm, is to be inputted into Donor ANT. Among this two kind of Paging Signal Band, 929MHz~932MHz bandwidth for sufficient Rejection via SAW Filter, But 940MHz~941MHz is difficult to gain big decreasing volume even if use SAW Filter because Band Edge is as close as to be folded to 935MHz~940MHz of being the frequency of iDEN900MHz Downlink. is possible 8 SPRINT User Manual iDEN 30dBm To prepare for this environment, Down Link of iDEN Repeater is designed to have additional Roll Off characteristic by decreasing band of SAW Filter in the station adjacent to paging signal, for it having the function of Adjust Band Edge that can decrease c of high frequency by 200 kHz, 400 kHz each.
<Pic.6> Additional Roll off through Adjust Band Edge 9 3. SPECIFICATIONS 3.1 System specifications SPRINT User Manual iDEN 30dBm Characteristic Specification Frequency Range Forward Reverse 800MHz 900MHz 800MHz 900MHz System Group Delay Characteristic Impedance VSWR Input Power Range Gain Range Noise Figure Gain Adjustment Step(Accuracy) Pass Band Ripple Maximum Output Power Spurious Emissions IF Frequency Adjacent Channel Power
@CH offset 25 KHz
@CH offset 50 KHz
@CH offset 500 KHz
@CH offset 1MHz 18 MHz BAND 17.8 MHz BAND 17.6 MHz BAND 7 MHz BAND 6.8 MHz BAND 6.6 MHz BAND 5 MHz BAND 4.8 MHz BAND 4.6 MHz BAND 18 MHz BAND 7 MHz BAND 5 MHz BAND 851~869 MHz 851~868.8 MHz 851~868.6MHz 862~869 MHz 862~868.8 MHz 862~868.6MHz 935~940MHz 935~939.8MHz 935~939.6MHz 806~824 MHz 817~824 MHz 896~901 MHz
< 8 50 ohm Max.1.5 : 1
-53 ~ -23dBm (FWD, RVS common) 40dB ~ 65 dB
< 5 dB @ Max Gain
<12 dB @Min Gain 1dB(0.5dB) 2.5dB(1.25dB) 31.6mW / 15dBm @ Composite Power 800MHz:12dBm, 900 MHz:12dBm
-13dBm FWD: 70 MHz, RVS: 70 MHz
> 50 dBm
@ Degradation of 3dB for eight iDEN carriers
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers 10 Adjust Band Edge SPRINT User Manual iDEN 30dBm
@CH offset 2 MHz
@ 869 MHz
@ 940 MHz Band Select Roll Offs
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers 868.8MHz/868.6MHz 939.8MHz/939.6MHz Local Shift & RF Switching
> 65dBc 3.2 Electrical and Environment Specifications Items Size(mm) / Type Power Temperature / Weight Connector TYPE specification 16(W)*18(L)*7(H) / Inch AC 120V 60Hz 3.0A 0 ~ +50/45.42 lbs N Type Female 3.3 Functions Parameter Gain Control AGC Auto Gain Control ALC Auto Limit Control Band Select Specification Adjustable DL and UL Gain range 40~65dB Display default Gain and current Gain function It always operates in Downlink AGC ON status To maintain same Downlink output power despite flexible input signal strength. To add or subtract Attenuation level referring to AGC Power Limit level. To limit output power as far as default range Set up via GUI Automatic Gain decrement when output power of repeater is higher than default level Automatic Gain recovery when output power of repeater is reduced. Shutdown when output power is higher than default level in Minimum Gain Automatic Recovery Algorithm conversion after Shutdown status In case of 800MHz FWD Band, it enables User to select one of 18MHz, 17.8MHz, 17.6MHz/ 7MHz, 6.8MHz, and 6.6MHz according to GUI setting. In case of 900MHz FWD Band, it enables User to select one of 5MHz, 4.8MHz, 4.6MHz according to GUI setting. In case of 800MHz RVS Band, it enables User to select one of 18MHz/
7MHz according to GUI setting. 11 Band Edge Adjust Power Monitoring Function Oscillation Check DL Input control Automatic Recovery Security Temperature control VSWR Monitoring IP address report SPRINT User Manual iDEN 30dBm In case of 900MHz RVS Band, it enables User to select 5MHz according to GUI setting. To shift Band edge of DL high frequency side by 200kHz, 400kHz step Monitoring repeaters output level Isolation Check in initial set up or Reset Monitoring Oscillation comparing to minimum/maximum Noise Floor level When Oscillation occurred, repeater attempts to stabilize Isolation through Gain control function. Shutdown repeater when Oscillation still goes in Minimum Gain Automatic Recovery Algorithm conversion after Shutdown status Monitoring Donor ANT input power of DL When in repeater shutdown, it periodically recovers output power of repeater then monitors alarming Support HTTPS for Web Browser security User authentication through User ID and Password Monitoring temperature of repeater Maximum and minimum set up is possible. Shutdown in over temperature Automatic recovery after temperature becomes normal. (Hysteresis 10degree) Monitoring VSWR of Donor ANT Port (Every one and half minute) Reporting VSWR Alarm and Shutdown when the rate is 3:1 Automatic Recovery Algorithm conversion after Shutdown status When in PPP reconnection, E-mail which includes HTML to connect to via E-mail newly assigned IP Address, reports to operator. DHCP Client DHCP Server Web GUI SNMP Agent LED Display Automatic IP assignment Server function for automatic IP assignment Remote and local user browser support through Web Browser NMS report via SNMPv2 Trap LED displays power and operation status on front side of repeater system. DL input and output signal level is verified by LED bar. 12 4. SET UP 4.1 System Set up 4.1.1 Constitution (based on 1 SET) SPRINT User Manual iDEN 30dBm Parameter Item Quantity Major accessory iDEN 30dBm repeater 1 EA Additional components Main power input Cable Mountable Bracket Fixable Screw Ground Cable Ethernet Cable(cross) Manual 1 EA 1 EA 1 SET 1 EA 1 EA 1 EA User Manual 4.1.2 Notice 1) System Power check: Major electricity is AC110V, therefore please input electricity after power verification.
<Pic.7> MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug) 2) Input condition optimization: DL input condition of iDEN is -53 ~ -23dBm. 3) Isolation check between DONOR/SERVER ANT: Isolation condition of this equipment is 80dBc (Gain+1 5dB). User should check its condition before installation. 4) This equipment is basically wall mountable installation. 13 SPRINT User Manual iDEN 30dBm
<Pic.8> Wall mounted iDEN In-building RF Repeater
<Pic.9> Hole sizes of iDEN In-building RF Repeater 14 SPRINT User Manual iDEN 30dBm 4.1.3 System set up 1) Once aforementioned process is done, open for service get ready. 2) For grounding, there is a grounding terminal in main power supply side and the grounding terminal on a site and unit should be connected same. 3) System installation work is basically performed more than two people and should be careful for unexpected accident. 4.1.4 Open for service 1) Check points before open a. Verification of system installation status Electricity, In/out antenna, coaxial cable connection, equipment mounts status. b. Verification of system accessories User should check whole necessary accessories. c. Check receipt signal level User should check whether receipt environmental condition is in accordance with system specification, so that system operation will be optimized. 2) Check points after open a. Check by external LED RUN: Green light ON (Off: Green light off) ALARM: Green light in normal status, Red light in alarmi SHUT DOWN: Green light in normal status, Red light in Shutdown iDEN ng Number of LED bar on front side of repeater will show input signal level.
-57dBm -48dBm: LED 1bar
-47dBm~-43dBm: LED 2 bars
-42dBm~-38dBm: LED 3 bars
-37dBm~-33dBm: LED 4 bars Up than 32dBm: LED 5 bars Number of LED bar in output power side will show output power signal level.
-10dBm~-6dBm: LED 1bar
-5dBm~-1dBm: LED 2bars 0dBm~+4dBm: LED 3bars
+5dBm~+9dBm: LED 4bars Up than +10dBm: LED 5bars 15 SPRINT User Manual iDEN 30dBm
<Pic.10> iDEN In-building RF Repeater front LED b. Verification via Debug Program User should check operation status of repeater system via Debug Program. c. Verification of operation status Use should verify following status with Output monitoring terminal, which is provided by Spectrum Analyzer.
- Output power generation status, system spurious emission characteristics. d. Verification of signal quality and strength in service area User should verify signal strength and quality of in-service coverage area by using cell phone or other terminal. e. Verification of upper-level NMS operation status 4.2 Troubleshooting In case, abnormal operation is detected, user should check abnormal parts via remote accessible function or field debug, then conduct repair after turn it off. 4.2.1 Necessary Testing and Measuring equipment a. RF Power Meter: 10Watt Max, 50ohm b. Signal Generator: 3GHz c. Spectrum Analyzer: 3GHz d. Multi Meter 4.2.2 Notice a. Trouble shooting should be performed with drastic knowledge basis. b. Unsure parts should not be disassembled. c. When in trouble shooting, technician should use attenuator to check output side. 16 SPRINT User Manual iDEN 30dBm 5. WEB USER INTERFACE 5.1 IP Address verification and Explorer setting 5.1.1 IP Address verification
(1) Start->Control Panel->Network Connections
(2) Double-click Local Area Connections at LAN or High Speed internet
(3) Click Internet Protocol (TCP/IP) at General tap and click Properties.
(4) Apply automatic IP address assignment at local connection 17 SPRINT User Manual iDEN 30dBm
(5) Verify assigned IP address at local connection.
(Unless IP address is not assigned, please click repair.) 5.1.2 Explorer option setting
- Proceed step by step as indicated in below. All files and records should be removed.
- Set up mode will be displayed after (2) click.
- Please proceed along following set up mode screen shot. 18 SPRINT User Manual iDEN 30dBm 5.2 Web UI 5.2.1 Web UI connection
- Input desirable IP address.
- Default Use Name and Password for Web UI is admin. 5.2.2 Link menu
- Following screen shot is located left-top side of main menu and those are linked to relative window. 5.3 Web UI control 5.3.1 Status
- Currently setting level check at this menu tap. 19 SPRINT User Manual iDEN 30dBm 5.3.2 RF Configuration
- Setting level can be changed at this menu tap.
- (1) Level change
- (2) Click Apply button 5.3.3 Alarm Configuration
- (1) On/Off function for entire alarm report
- (2) Alarm status
- (3) On/Off function for individual alarm category 20
- (4) Alarm SNMP Mapping
- User may set and change its level per it field condition and click apply button. SPRINT User Manual iDEN 30dBm 5.3.4 Communication Configuration
- This provides all necessary information related to network
- To provide relative information about DHCP and modem 5.3.5 User Management
- Add and Remove user, Assigning accessibility
- (1) User Registration: Click Register after input required information
- (2) User Removal: Click Delete upon click of user name you wish to remove.
- (3) Super User: Accessible to all kinds of information path 21 Read/Write: Accessible to all kinds of information path except for User management path. Read: Checking status only. No control SPRINT User Manual iDEN 30dBm 5.3.6 Logs
- All users access record will be saved as a log. 5.3.7 Sub System/Mailing List
- Set up e-mail address the place you wish to receive alarm. 5.3.8. Troubleshooting Following is a trouble shooting table, which is frequently occurred to repeater and treatment me thod. 22 SPRINT User Manual iDEN 30dBm 5.3.9 Remote Software Upgrade
- Upload repeater operation program. 5.3.10 System Reset
- Reset repeater. 23 SPRINT User Manual iDEN 30dBm 24