PIR ALARM KIT RL-9830G4 Version1.0 Package Contents ON OFF PIR alarm
(Main unit)
*2 Remote key fob
(Transmitter)
*2 magnetic sensor Door/window
(Transmitter)
*4 Vibration alarm
(Transmitter, 3M stickers included)
*2 Bracket
*2 Screw pack
*2 User manual
*1 Before using the product, please remove the insulation sheets from all transmitters. 2 screws together with 2 plastic plugs (for installing the main unit brackets) and 4 3M stickers(for door/window magnetic sensors)are included in each screw pack. The main unit includes a receiver module and a transmitter module inside. PIR alarm (Main unit) Code button Speaker Indicator light PIR sensing area Alarm indicator: When the main unit sounds an alarm, the light will ash quickly along with the alarm sound. Low battery indicator: When the batteries installed in the main unit reach a low level, i.e., less than 3.3V, the light will ash slowly (time interval of 3 seconds). Please replace batteries immediately when the low battery indicator light ashes. Remote key fob (Transmitter) Door/window magnetic sensor
(Transmitter) Arm button Disarm button ON OFF AWAY mode HOME mode Front view Side view Magnetic contact Vibration alarm (Transmitter) Indicator light Once paired to the main unit and in the ARM mode if the magnetic contact is separated from the door/window sensor the alarm will sound. To disarm the alarm press the OFF button on the remote key fob. Once paired to the main unit and in the ARM mode if the vibration alarm is triggered by a vibration, it will sound or send a wireless signal to the main unit. The main unit will sound when it receives the wireless signal from the vibration alarm. To disarm the alarm press the OFF button on the remote key fob. Speaker Paring the Transmitters to the PIR Alarm A B Y R B A
-
E
+
T T T T
-
E
+
A B R Y B A
-
T T E
+
R Y Y R B A
-
E
+
T T T T
-
E
+
A B R Y B A
-
T T E
+
R Y 30s A a ON OFF b A 1. Insert batteries to the PIR alarms A and B. 2. For the PIR alarm A, press the Code button for 3 seconds by inserting the screwdriver. A single
"Beep" will be heard. 3. Release the screwdriver and within 30 seconds:
3a. Remote key fob: press any button 3b. Vibration alarm: slide the switch to "RF" and then knock on the vibration alarm. It will send a wireless signal to the main unit. d c A B 3c. Door/window magnetic sensor:
Separate the magnetic contact from the alarm, the red indicator light will be on. 3d. PIR alarm B: press the Code button by inserting the screwdriver. A A 4. The PIR alarm A will give one "Beep" tone to indicate that the signal is received. 5. Press the Code button again for 3 seconds by inserting the screwdriver. Two "Beep" tones will be heard. 6. Release the screwdriver, pairing is now completed. Also pair the transmitters to the PIR alarm B by following the steps above. You can add up to 32 transmitters to each PIR alarm. Clearing Code
-
B A T T E R Y
+
Y R E T T A B
-
Installation PIR alarm
+
The PIR alarm A or B Press and hold the Code button by inserting the screwdriver (as above) before installing the batteries. Insert batteries you will hear two "Beep" tones that will conrm that the clearing code has been successful. NOTE: The above will clear the code for all paired transmitters.
-
B A T T E R Y
+
2-6M 90 RF Off RF+Alarm Battery Compartment 1 Switch Operation:
OFF: Power off. RF: When triggered, it itself will not sound but will send a wireless signal to the main unit. RF+ALARM: Three "Beep" tones will be heard when powered. When triggered, it will send a wireless signal to the main unit and after 2 seconds it itself will also sound for 8 seconds. Firstly, install the bracket and attach the main unit to the angle of the PIR alarm bracket and adjust the angle accordingly. The detecting range and angle of the PIR alarm 2 CR2032 LR44 LR44 LR44 Door/window magnetic sensor 1. Open the battery compartment to insert a battery. 2. Fix the unit on the door or window by using a 3M sticker. Vibration Alarm 1. Open the battery compartment to insert batteries. 2. Fix the unit on the window by using a 3M sticker. Arming/Disarming via Remote Key Fobs Remote Key Fob: Press "ON" to ARM the unit, "OFF" to DISARM the unit. Switch: " " into the AWAY mode while " " is the HOME mode. 1) AWAY Mode Slide the switch to " " AWAY mode and press "ON", the main unit will give one "Beep" tone. After 30 seconds, the unit will enter into the ARM mode. If the door/window installed with the magnetic sensor is opened or the window installed with the vibration alarm is knocked or someone enters the property and the PIR alarm detects the intrusion, the PIR alarm will sound. To disarm the alarm press "OFF" on the remote key fob. When the PIR alarm receives the DISARM command,it will give two "Beep" tones and if it is in the ALARM status, the sound will be immediately turned off. 2) HOME Mode For use in the HOME mode you must use the door/window magnetic sensors or the vibration alarm. Slide the switch to
" " HOME mode and press "ON", the main unit will give one "Beep" tone. After 30 seconds, the unit will enter into the ARM mode. NOTE: In this mode the PIR sensor is disabled, therefore, your windows and doors are protected by magnetic sensors or vibration alarms whilst you are in the property. If a door or window is opened or knocked, the alarm will sound. To disarm the alarm press "OFF" on the remote key fob. NOTE: The description above is only for the system with one PIR alarm. If you want 2 PIR alarms in the system and want them to be interlinked, they both must be paired to each other and be paired to the transmitters respectively. After, you must arm 2 PIR alarms with the remote key fob. Once armed, 2 PIR alarms will sound if any transmitter is triggered. In the AWAY mode, no matter which PIR alarm detects human movements, 2 PIR alarms will sound. Remote key fobs can only turn off the sound of the PIR alarm. The sound of the vibration alarm, however, will be auto stopped after 8 seconds. Technical Specications PIR alarm (Main unit) Working Voltage Working Current Standby Current Low Voltage Indicator Alarm Volume Wireless Frequency Infrared Detective Distance DC 4.5V(1.5V/AA/LR6*3) 100mA 0.5mA 3.3V 100dB(30cm) 433.92MHz250KHz 6m Infrared Alarm Angle 100 Arm Mode Alarm Mode Alarm Time Wireless Distance Arming delays 30s each time Alarm once triggered 30s each time 30m (no barrier) 3 Remote key fob
(Transmitter) Working Voltage DC 3.0V(CR2032) Standby Current
<2uA Working Current 12mA Door/window magnetic sensor
(Transmitter) DC 3.0V(CR2032) 10uA 15mA Vibration alarm
(Transmitter) 4.5 V (3x battery LR44) 6uA RF: <15mA RF+ALARM: <100mA Working Frequency 433.92MHz250KHz 433.92MHz250KHz 433.92MHz250KHz Working Distance Alarm Volume (30cm) Time Interval of Each Vibration
>30m(no barrier) 80m (no barrier) 80m (no barrier)
/
/
/
/
>95dB 5s Tips Recommended installation height: 1.60.3m, adjust the installation angle to face downward. Do not install the product in direct sunlight or close to a radiator or heat source. The detection range of the PIR alarm may vary slightly due to different environments. Do not attempt to repair this product, please return to your retailer According to the co-channel interference principle, the receive distance may be affected if a strong interference signal exists within the using area. If a car is travelling nearby, the receive distance may be affected as well.. Remove batteries if the product is not in use for a long time and dispose the batteries according to the local laws and regulations. Troubleshooting 1. The main unit false alarms. Check if any animals are in the vicinity of the PIR sensor, During warm weather moving shadows may also activate the alarm. Make sure that the PIR sensor is not positioned near a radiator or heat source. Check if any appliances within the property are emitting a strong electromagnetic eld near the door/window magnetic contact. Strong electromagnetic elds may cause the door/window magnetic contact to false alarm. 2. The main unit cannot receive the signal sent from the transmitter (remote key fob or door/window magnetic contact). Check if the pairing between the transmitter and the main unit has been successful. If the pairing was successful, check the battery voltage for both the main unit and the transmitter. Low voltage will cause the product to fail. 3. When the PIR alarm detects movement, however, no alarm sounds. Check if the low battery indicator is ashing (please replace batteries immediately). If the unit is armed and set in the HOME mode and the PIR sensor detects an intrusion the alarm will not sound. The PIR is disabled in the HOME mode. Check if the main unit is installed correctly. FCC Statement Warning: Changes or modications to this unit not expressly approved by theparty responsible for compliance could void the user's authority to operate theequipment. NOTE: This equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance with theinstructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment off andon, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to whichthe receiver is connected. Consult the dealer or an experienced radio/TV technician for help The device must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions :
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. 4