Wi-Fi Keypad Controlled Door Alarm Sensor RL-WD02A Version 1.0 Package Contents Main Unit*1 Magnet *1 Door-Closing Reminder Volume Selection Indicator Light Password Keypad Use sensor on either side Reset Button Battery Compartment 1 Operating Instructions Download the APP to your smart mobile phone A. Downloading the APP by one of the following methods:
1. On your mobile phone go to the App Store or Google Play. Then, do a search for TuyaSmart. 2. Scan the QR code below to download. During the setup process, select + (Add Device) > Others > Others (Wi-Fi) as below. 2. Device Reset 2. Device Reset a. EZ mode Press and hold the Reset button for above 5 seconds, the indicator light will rapidly blink to indicate that network is reset and entering into EZ mode. 5s ... 2. Reset and Change the Password The initial password is: 1234;
Under Disarmed state, press for above 5 seconds, a long Di tone that lasts for 2 seconds will be heard. a. Within 10 seconds, input the 2 Rapid blink 60s TuyaSmart 1 Android 5.0 / iOS 8.0 or higher 1) Place the unit next to the home router (2.4G WiFi) and ensure batteries are installed. 2) Please connect your mobile phone and the B. Adding the Device device to the same WiFi network, and then launch the APP TuyaSmart . 3) For the steps of adding the device, please check the Help documents. Tap Me on the lower right of the screen and then tap FAQ &
Feedback. NOTE:
After reset, the indicator light will flash rapidly. For the details, please refer to the section Device Reset. NOTE:
The step-by-step instructions on the app may slightly vary due to the app update. Simply follow the actual instructions on the app when adding the device. b. AP mode Under EZ mode, press and hold the Reset button for above 5 seconds, the indicator light will slowly blink to indicate that it has switched to AP mode. If timed out (60s), it will automatically enter into standby state. To retry, please reset and congure again. C. APP FAQ 1. Failed to add the device 1) Please check whether the network you connected is 2.4GWiFi. D. Function Description 1. Indicator Light
- Rapid blink: Conguring Wi-Fi in EZ mode (2 blinks/second) 2) Please check whether the WiFi password you
- Slow blink: Conguring Wi-Fi in AP mode (1 blink/3 typed is correct. seconds) 3) If the above operation is correct, reset the 1. The APP cannot find a new device when adding the device. device and add it again.
- Double blink: Connecting to Wi-Fi...
- Steady On: Wi-Fi connected, connecting to the Cloud... new 4-digit password and your mobile phone will receive a message about this modification. b. If no input within 10 seconds, the password will be set to 1234 by default and your mobile phone will receive a message about this setting. 3. Arming/Disarming Input the password to switch between Armed and Disarmed state (Each time you power on the unit, it will be set to Disarmed state).
- Disarmed successfully: Two Di tones will be heard and the indicator light will blink twice.
"Disarmed successfully" message will be found in app message center and "Armed away disabled" will be displayed on the app operation page.
- Armed successfully: One Di tone will be heard and the indicator light will blink once (there will be a 15-second arm delay). "Armed successfully"
message will be found in app message center and
"Armed away enabled" will be displayed on the app operation page. 2 3 3 4 5 4. Low Battery Indicator When the battery voltage is low(<3.3V), a push notication will be sent to the APP for an alert. Please replace batteries immediately. the magnet is separated from the main unit and no correct password is input within 10 seconds. In this situation, input a correct password to stop the alarm. 5. Door-Closing Reminder:
5.1 TIPS ON/OFF i T p s o i T p s o n TIPS ON When the switch is slid to TIPS ON position, the main unit will prompt 6 "Di" tones and "Door opened" message will be found in app message center and setting page if the magnet is separated from the main unit (door is opened) for 1 minute. When the switch is slid to TIPS OFF position,
"Door opened" message will be found in app message center and setting page if the magnet is separated from the main unit (door is opened) for 1 minute; the main unit will not have prompt tones. When the magnet is attached to the main unit,
"Door closed" message will be found in app message center and setting page. 5.2 Illegal Entry Once armed successfully, "illegal entry" message will be found in app message center and setting page if the magnet is separated from the main unit
(door is opened). After armed successfully, it will sound an alarm and the indicator light will ash for 30 seconds if 6. Illegal Entry Alert When illegal entry alert is enabled, the alert as figure shown will be displayed on the app operation page if illegal entry occurs. 7. Mute When mute function is enabled via the app, the main unit will turn off sound. 8. Wrong Password Reminder Once armed successfully, "illegal entry" message will be found in app message center and setting page if the magnet is separated from the main unit
(door is opened). After armed successfully, it will sound an alarm and the indicator light will ash for 30 seconds if the magnet is separated from the main unit and no correct password is input within 10 seconds. In this situation, input a correct password to stop the alarm. Troubleshooting Technical Specifications FCC Warnings 1. The indicator light double blinks for 20 seconds. This indicates that it failed to connect to WiFi and now is attempting to re-connect. Check if the WiFi signals is normal. 2. After the device is triggered, the indicator light is Steady On. This indicates that the device is connecting to the Cloud. If App fails to receive the notication, please check WiFi to see if it works properly. 3. When triggered, however, no push notication received. Please check the mobile phone setting to see if notications are allowed. Also, check if WiFi works properly. CAUTION
Batteries may leak harmful liquids or ignitable materials or explode causing injury and product damage Do not mix old and new or other battery types Replace all batteries at the same time Remove batteries if product is to be unused for extended periods of time Battery DC 4.5V (AAA*3) Standby Current
<130uA Working Current Volume HIGH<140mA Volume LOW<80mA Alarm Volume
(30cm) HIGH>100db LOW 90-100db Wireless Protocol Working Temperature WiFi2.4GHz
-10~50 Wireless Distance between the Device and Router Open Area: 60~80m NOTE:
Alkaline batteries are recommended. The product is for indoor use only. Do not install outside. Warning: Changes or modications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference
(2) this device must accept any interference received, including interference that may cause undesired operation. Shielded cables must be used with this unit to ensure compliance with the Class B FCC limits. NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCCs RF Exposure guidelines, This equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna. 6 7 8 9 10