User Manual Pro Cellular Blood Pressure Monitor TMB-2092-G Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China version:1.0 TeleCuff Gen 2 TABLE OF CONTENTS INTRODUCTION General Description Indications for Use Contraindications Measurement Principle Safety Information Display and Symbols Name of Each Part Contents/Product Includes BEFORE YOU START The Choice of Power Supply Installing and Replacing the Batteries MEASUREMENT Applying the cuff A: Using Single Measurement Mode B: Using Triple Measurement Mode INFORMATION FOR USER Tips for measurement Maintenances ABOUT BLOOD PRESSURE TROUBLESHOOTING SPECIFICATIONS AUTHORIZED COMPONENT CONTACT INFORMATION EMC GUIDANCE FCC STATEMENT What are systolic pressure and diastolic pressure?
What is the standard blood pressure classication?
Why does my blood pressure uctuate throughout the day?
Why do l get a different blood pressure at home compared to the hospital Is the result the same if measuring on the righe arm?
3 10 12 17 19 22 23 24 24 25 28 2 INTRODUCTION INTRODUCTION General Description Safety Information Thank you for choosing this arm type Pro Cellular Blood Pressure Monitor (TMB-2092-G). It is equipped with the following key features. Please read this manual to know how to use your Blood Pressure Monitor safely and correctly. Keep the manual well for future reference. The symbols below might be in the user manual, labeling or other component. They are the requirement of standard and using. Real-time Data Transmission Remote Care, Any Time, Anywhere AC Adaptor available
(not included) Date of Manufacture Temperature limit One-Click Operation 4G Large 4.5-inch LCD display Measurement Reminder Indications for Use This Pro Cellular Blood Pressure Monitor TMB-2092-G is a digital monitor intended for use in measuring blood pressure and heartbeat rate with arm circumference ranging from 22 to 42 cm (or 22 to 45 cm). It is intended for adult. Contraindications 1. The device is not suitable for use on neonates, infants, or children. 2. The effectiveness of this device has not been eatablished in pregnant,including pre-eclamptic, patients. Measurement Principle This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a zero pressure equivalent to the atmospheric pressure.Then it starts inating the arm cuff,meanwhile, the unit detects pressure oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic pressure, and also pulse rate. The operation guide must be read Type BF applied parts Consult instructions for use Symbol for Serial Number Direct Current Manufacturer Recyclable Humidity limitation Atmospheric pressure limitation MR Unsafe This device is not intended to operate in Magnetic Resonance environment. Do not take the device into MR environments. Indicates the need for the user to consult the instructions for use for important cautionary information such as warnings and precautions that cannot, for a variety of reasons, be presented on the medical device itself. Symbol for ENVIRONMENT PROTECTION - Electrical waste products should not be disposed of with household waste. Please recycle where facilitiesexist. Check with your local authority or retailer for recycling advice 3 4 INTRODUCTION INTRODUCTION CAUTION CAUTION
* This device is intended for indoor use.
* This device is portable, but it is not intended for use during patient transport.
* The device contains sensitive electronic components.To avoid measurement errors, avoid taking blood pressure measurements near a strong electromagnetic eld radiated interference signal or electrical fast
* This device is not suitable for continuous monitoring during medical emergencies or operations. transient/burst signal.
* This device is intended for no-invasive measuring and monitoring of arterial blood pressure. It is not intended
* Wireless communication equipment, such as wireless home network devices, mobile phones, cordless for use on extremities other than the arm, or for any purpose other than obtaining a blood pressure telephones and their base stations,walkie-talkies may cause interference that may affect the accuracy of measurement. measurements. A minimum distance of 1 foot (30 cm) should be kept from such devices during a
* This device is for adults. Do not use this device on neonates or infants. Do not use it on children unless measurement. otherwise instructed by a medical professional.
*The effectiveness of this device has not been established for use:
-on the women in pregnant, including pre-eclamptic, patients,
* You can use this device to take your own measurement, no third-party operator is required.
* Please use the device under the environment which is provided in the user manual. Otherwise, the performance and lifetime of the device will be impacted and reduced.
-on patients with implanted, electrical devices, such as cardiac pacemakers, debrillators,
* The device may require up to 30 minutes to warm up / cool down from the minimum / maximum storage
-on users with common arrhythmias such as atrial or ventricular premature beats or atrial brillation, temperature before it is ready for use.
-on users undergoing intravascular therapy, or with arteriovenous (AV) shunt.
* Warning: Do not touch output of the batteries/adapter and the user simultaneously.
* Adapter is specied as a part of ME EQUIPMENT.
* Do not use this device for diagnosis or treatment of any health problem or disease. Contact your physician if
* Warning: The power cord is considered the disconnect device for isolating this equipment from supply you have or suspect any medical problem. Do not change your medications without the advice of your mains.Do not position the equipment so that it is difficult to reach or disconnect.
* If you are taking medication, consult your physician to determine the proper time to measure your blood
* Warning: Do not use this device if you are allergic to polyester, nylon, or plastic.
* This device may be used only for the intended use described in this manual, the manufacturer shall have no damage to the unit and injure users. liability for any incidental, consequential, or special damages caused by misuse or abuse.
* Warning: If you experience discomfort during a measurement, such as pain in the arm or other complaints,
* Report any unexpected operation or events to the manufacturer. press the Power button immediately to release the air from the cuff.
* Warming: Do not kink,fold,stretch,compress,or otherwise deform the tube during measuring, as the cuff
* No calibration is required within two years of reliable service.
* Do not apply the cuff on an arm that has an intravenous drip or a blood transfusion attached.
* Do not attempt to repair the unit yourself if it malfunctions. Only have repairs carried out by authorized pressure might continuously increase, which could prevent blood ow and result injury. service centers.
* Warning: Taking blood pressure measurements too frequently could disrupt blood circulation and cause
* At the request of authorized service personnel, circuit diagrams, component part lists, descriptions, and
* Warning: Only use accessories approved by manufacturer. Using unapproved accessories might cause
-on users with peripheral arterial disease, Consult a medical professional before use. physician or health care professional. pressure. injuries. for irritation. disrupt blood circulation and cause injuries. calibration procedures will be made available by the manufacturer or distributor.
* It is recommended that the performance should be checked after repair, maintenance, and every two years of use,by retesting the requirements in limits of the error of the cuff pressure indication and air leakage
(testing at least at 50 mmHg and 200 mmHg). treatment, i.e. intra-vascular access or intra-vascular therapy or an arteriovenous (A-V) shunt, which could
* Warning: Do not use the device while under maintenance, or being serviced.
*Do not place the cuff on the arm on the same side of a mastectomy(especially when lymph nodes have been dust and direct sunlight. Never place any heavy objects on it. removed).it is recommended to take measurements on the unaffected side.
*Make sure the rubber tube of the cuff is not squeezed,stretched,or kinked during storage.
*Do not wrap the cuff on the same arm to which another monitoring device is applied.One or both devices
*Warning:Keep the device,cuff,and batteries away from children as they may pose a risk of choking or could temporarily stop functioning if you try to use them at the same time. strangulation if used improperly.
* Warning: Do not use this device with high-frequency (HF) surgical equipment at the same time.
* Dispose of accessories, detachable parts, and the device according to the local guidelines. Do not use alcohol, benzene, or other harsh chemicals. Do not wash teh cuff in a washing machine or dishwasher!
* The service life of the cuff may vary by the frequency of washing,skin condition,and storage state.The typical service life is 10000 times.
* Please check that the operation of the device do not result in prolonged impairment of patient blood circulation. constant pressure >15 mmHg for more than 3 minutes) might lead to bruising and discolored skin.
* Warning: This device is not AP/APG equipment. Do not use the device where ammable anesthetic are present, or in environments mixture with air of with oxygen or nitrous oxide. 5 6 INTRODUCTION Display and Symbols INTRODUCTION SYMBOL EXPLANATION 1 2 3 4 5 SYMBOL EXPLANATION Systolic blood pressure reading Diastolic blood pressure reading Pulse display Heartbeat icon Flashes when detected during the measurement. warning messages, refer to page 22 for more information. Measurement reminder icon When it is activated, appear on the display and remind the user to measure at the certain time. 15 14 13 12 11 10 9 8 7 6 1 2 3 4 5 6 5 7 7 8 9 10 11 12 13 14 15 Triple Measurement icon Indicates the current measurement mode is [Triple Mode], and which measurement progress it is. Cuff wearing detection icon will appear if the cuff is not wrapped or wrapped too loose when measuring. Cuff abnormal icon Appears when the air connector plug is not properly plugged in or a leak of the cuff is detected. Excessive body motion detector icon Appears when talking, moving, or shaking of the arm with the cuff on is detected during a measurement. NOTE: The measured blood pressure reading may not be accurate when this symbol is displayed with the reading. SIM card error icon Appears when the SIM card is abnormal or the SIM is not properly plugged in. Data pending to transmit icon Appears when the data transmission failed. Up to 500 measurements can be temporarily saved on the device and send to your account when the Cellular internet is available. Signal indication icon Indicates no cellular coverage or cellular connection error. Adapter Insert Indicator Appears when the power is supplied from the adapter. Battery Indicator Indicate the current battery. Low battery symbol Indicate the battery is too low when appears with . 8 8 INTRODUCTION BEFORE YOU START Name of Each Part The Choice of Power Supply CUFF AIR CONNECTOR PLUG AIR HOSE LCD DISPLAY AC ADAPTER PORT
[TRIPLE MODE] BUTTON
[START/STOP] BUTTON 1. DC 6V, 4 AA size batteries 2. AC adapter, 6V 1A Please use the AC adapter authorized by the manufacturer!
Please unplug the adapter to depart from the using utility power, when you nish the measurement. AC adapter CAUTION In order to get the best effect and protect your monitor,please use the rightbatteries and special power adapter which complies with local safety standard. BATTERY COMPARTMENT BATTERY COVER Slide off the battery cover.. Installing and Replacing the Batteries Contents/Product Includes 1 Pro Cellular Blood Pressure Monitor (TMB-2092-G) 1 Cuff (Type BF applied part) Upper arm circumference: 22-45 cm Upper arm circumference: 22-42 cm (optional) 1 User Manual 1 Quick Start Guide 4 AA size batteries 1 AC Adapter ( BLJ06L060100P-U) (optional) Install or replace 4 AA size batteries according to the polarity indications inside the battery compartment. Place back the battery cover. Replace the batteries whenever the below happens appear on the LCD display. The display dims. The display does not light up. CAUTION Do not use new and used batteries together. Do not use different types of batteries together. Do not dispose the batteries in re. Batteries may explode or leak. Remove batteries if the device is not likely to be used for some time. Worn batteries are harmful to the environment. Do not dispose with daily garbage. Remove the old batteries from the device following your local recycling guidelines. 9 10 BEFORE YOU START MEASUREMENT Note A:
When you insert or replace batteries into the device, the LCD displays as below rst, and then it will turn off after about 5 seconds. LCD display Applying the cuff 1. Remove all jewelry, such as watches and bracelets from your left arm. Note: If your doctor has diagnosed you with poor circulation in your left arm,use youre right arm. Roll or push up your sleeve to expose the skin. Make sure your sleeve is not too tight. Hold your arm with palm facing up and tie the cuff on your upper arm, then align the air tube toward the center of your arm. Make sure the bottom edge of the arm cuff 1 inch (2-3 cm) above the inside elbow. Then wrap the cuff securely. Note:The cuff should be snug but not too tight. You should be able to insert one nger between the cuff and your arm. 5. Sit upright in a comfortable chair with your back against the backrest of the chair. Keep your feet at and your legs uncrossed. Place your arm resting comfortably on a at table. The cuff worn on your arm should be placed at the same level as your right atrium of the heart. 6. Take 5-6 deep breaths and let's start measuring!
2. 3. 4. 2-3 cm (~1 inch) The device will then search and pair with the mobile network automatically after it is turned off. If unsuccessful, the monitor will stop searching and enter the standby mode. Note B:
This device is equipped with function of Measurement Reminder. Contact Customer Support to enable or disable it, maximum 5 group of measurement Reminder (by default, it is disabled). Once enabled, every day when the appointment time is reached, the blue LED of the device button will light up in the form of breathing light to remind the user to measure, and the breathing light will be cancelled after the startup or 30 minutes without operation.
(If the user does not measure the blood pressure according to the reminder, the reminder icon of measurement will not be displayed when the user starts the measurement next time) Helpful tips to help ensure an accurate reading Take the measurement in a silent room. Rest for 5 minutes before a measurement. Be relaxed, Remain still and DO NOT talk while taking a measurement. For a meaningful comparison, try to measure under similar conditions. For example, take daily measurements at approximately the same time, on the same arm, or as directed by a physician. 511 12 12 MEASUREMENT MEASUREMENT A: Using Single Measurement Mode Start a measurement When the TRIPLE MODE button is located on OFF, the monitor is under the Single Measurement mode. When the monitor is OFF, press the START/STOP button to turn on, and then it will complete the whole measurement automatically. LCD display Adjust the zero point Inating and measuring Display the measured result 2. After the measurement, the data transmission starts. The symbol will appear on the LCD. If successful, the symbol will disappear and the LCD will display . Press the START/STOP button to turn off the device, otherwise it will power off automatically within several seconds. During the data transmission, If the data transmission error or server connection error occurs, The symbol will appear on the LCD. Refer to page 22 for more information. During the data transmission, If no cellular coverage or cellular connection error occurs, The symbol will appear on the LCD. Refer to page 22 for more information. 513 14 MEASUREMENT MEASUREMENT B: Using Triple Measurement Mode When the TRIPLE MODE buton is located on ON, the monitor is under the Triple Measurement mode. 1.When the monitor is off , press the START/STOP button to turn on, and then it will complete the whole measurement automatically. LCD display Display the zero point Inating and measuring 2.When the rst measurement is done, it wont show the readings. It will start the second measurement after 60 seconds. 3. Then it will repeat the steps to nish the third measurement. When three measurements are done, the LCD will display the average of 3 readings. Tip:
If the measurement fails in the process of 3 munimes, it will report an error and repeat the current measurement. If the error occurs for 2 times in a row, the mode of 3 times measurement will be automatically quit. 4. After the measurement, it will repeat the data transmission steps as described on pape 14. Tip:
any time. You can press the START/ STOP button to stop the measurement 515 16 INFORMATION FOR USER INFORMATION FOR USER Tips for Measurement Maintenance Measurements may be inaccurate if taken in the following circumstances. In order to get the best performance, please follow the instructions below. Within 1 hour after dinner or drinking Immediate measurement after tea, coffee,smoking Put in a dry place and avoid the sunshine Avoid touching water, clean it with a dry cloth in case. Within 20 minutes after taking a bath When moving your ngers or talking Avoid intense shaking and collisions Avoid dusty and unstable temperature environment In a very cold environment When you want to urine Using wet cloths to remove dirt Avoid washing the cuff 517 18 ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure?
CAUTION When ventricles contract and pump blood out of the heart, the blood pressure reaches its maximum value in the cycle, which is called systolic pressure. When the ventricles relax, the blood pressure reaches its minimum value in the cycle, which is called diastolic pressure. Only a physician can tell your normal BP range. Please contact a physician if your measuring result falls out of the range. Please note that only a physician can tell whether your blood pressure value has reached a dangerous point. Systolic blood discharging artery Diastolic blood entering vein press relax What is the standard blood pressure classication?
The following chart is the standard blood pressure classicatio n published by American Heart Association (AHA). This chart reects blood pressure categories dened by American Heart Association. Blood Pressure Category Systolic mmHg (upper#) Diastolic mmHg (lower#) Normal less than 120 and less than 80 Elevated 120-129 and less than 80 High Blood Pressure
(Hypertension) Stage 1 High Blood Pressure
(Hypertension) Stage 2 130-139 80-89 140 or higher 90 or higher or or Hypertensive Crisis
(Consult your doctor immediately) Higher than 180 and/or Higher than 120 519 20 ABOUT BLOOD PRESSURE TROUBLE SHOOTING Why does my blood pressure uctuate throughout the day?
1.Individual blood pressure varies multiple times everyday.It is also affected by the way you tie your cuff and your measurement position,so peease take the measurement under the same conditions. 2. If the person takes medicine, the pressure will vary more. 3. Wait at least 3 minutes for another measurement. PROBLEM DISPLAY CHECK THIS REMEDY No power Display can not light up. Batteries are exhausted. Replace with new batteries. Batteries are installed incorrectly or Adapter is not plugged in properly. Install the batteries or plug in the adapter properly. High Battery The DC supply voltage is too high or too low. Replace with the authorized adapter. Low Battery The battery is too low. Replace with new batteries. Why do I get different blood pressure at home compared to the hospital?
The blood pressure is different even throughout the day due to weather,emotion,exercise etc.Also,there is the white coateffect,which means blood pressure usually increases in clinical settings. What you need to pay attention to when you measure your blood pressure at home:
If the cuff is tied properly. If the cuff is too tight or too loose. If the cuff is tied on the upper arm. If you feel anxious. Taking 2-3 deep breaths before beginning will be better for measuring. Advice: Relax yourself for 4-5 minutes until you calm down. Error message Is the result the same if measuring on the right arm?
It is ok for both arms,but there will be some different results for different people. We suggest you measure the same arm every time. The cuff is not wrapped or wrapped too loose. Wrap and fasten the cuff and measure again. The air connector plug is not properly plugged in or a leak is detected. Insert the air tube plug correctly, then measure again. If the issue persistscheck the cuff leakage. Excessive body motion
(such as shaking of the arm with the cuff on) is detected. Relax and then measure again. When the issue persists twice, will display on the LCD, please contact customer support. Pulse is not detected during measuring. Out of measurement range Data transmission error or Server connection error No cellular coverage or Cellular connection error SIM card is not detected or SIM card is abnormal. Hardware error Relax and then measure again. When the issue persists twice, will display on the LCD, please contact customer support or contact your physician. Move to another area, preferably closer to a window, try again. Use the device at a location where you get strong cellular signal with your mobile phone. If the issue persists, contact customer support. Check and re-install the SIM card. If the issue persists, contact customer support. Retake measurement. If the issue persists, contact customer support. 521 NOTE: If the product still does not work, contact the Customer Service. Under no circumstance should you disassemble or attempt to repair the unit by yourself. 22 SPECIFICATIONS AUTHORIZED COMPONENT Please use the authorized adapter External dimensions Approx.148.3 mm 100.5 mm 52 mm Display mode Digital LCD V.A. 79 mm 93 mm Weight Approx.325 g (Excluding the batteries and cuff) Measurement mode Oscillographic testing mode Mode of operation Continuous operation Measurement range Rated cuff pressure:0mmHg~299mmHg Measurement pressure:
SYS: 60 mmHg ~ 230 mmHg DIA: 40 mmHg ~ 130 mmHg Pulse value: (40-199) beat/minute Accuracy Pressure: 5C-40C within 3 mmHg Pulse value: 5%
Normal working condition Storage condition &
transportation condition Measurement perimeter of the upper arm Device Classication Protection against ingress of water Expected Lifetime Temperature: +5C to +40C Relative humidity: 15% to 90%, non-condensing, but not requiring a water vapour partial pressure greater than 50 hPa Atmospheric pressure: 700 hPa to 1060 hPa Temperature: -20C to +60C Relative humidity: 93%, non-condensing, at a water vapour pressure up to 50 hPa About 22-42 cm or 22-45 cm Battery Powered Mode:
Internally Powered ME Equipment AC Adaptor Powered Mode: Class II ME Equipment IP21, It means the device could protected against solid foreign objects of 12.5 mm and greater, and protect against vertically falling water drops. 5 years or 10,000 measurements
(may vary based on usage conditions) Degree of protection Type BF applied part WARNING: No modication of this equipment is allowed. 523 Adapter Type: BLJ06L060100P-U Input: 100-240V, 50-60Hz, 0.2A max Output:
6V 1000 mA CONTACT INFORMATION For more information about our products, please visit www.transtekcorp.com. Manufactured by:
Guangdong Transtek Medical Electronics Co., Ltd. Company:
Guangdong Transtek Medical Electronics Co., Ltd. Address:
Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China 24 EMC GUIDANCE The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments. Warning: Dont be near the active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high. Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. Warning: Use of accessories, transducers and cables other than those specied or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the equipment TMB-2092-G including cables specied by t he manufacturer. Otherwise, degradation of the performance of this equipment could result. Technical description 1. All necessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the excepted service life. 2. Guidance and manufacturers declaration-electromagnetic emissions and Immunity. Guidance and manufacturers declaration - electromagnetic emissions Table 1 Emissions test RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 525 Voltage uctuations / icker emissions IEC 61000-3-3 Compliance Group 1 Class B Class A Comply EMC GUIDANCE Table 2 Guidance and manufacturers declaration electromagnetic Immunity Immunity Test IEC 60601-1-2 Test level Compliance level Electrostatic discharge (ESD) IEC 61000-4-2 Electrical fast transient/burst IEC 61000-4-4 Surge IEC61000-4-5 Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 8 kV contact 2 kV, 4 kV, 8 kV, 15 kV air 8 kV contact 2 kV, 4 kV, 8 kV, 15 kV air 2 kV for power supply lines 1 kV signal input/output 100 kHz repetition frequency 2 kV for power supply lines NA 100 kHz repetition frequency 0.5 kV, 1 kV, differential mode 0.5 kV, 1 kV, 2 kV common mode N/A 0% UT; 0,5 cycle. At 0, 45, 90, 135, 180, 225, 270 and 315. 0% UT; 1 cycle and 70% UT ;
25/30 cycles; Single phase: at 0. 0% UT; 250 / 300 cycle 0% UT; 0,5 cycle. At 0, 45, 90, 135, 180, 225, 270 and 315. 0% UT; 1 cycle and 70% UT ;
25/30 cycles; Single phase: at 0. 0% UT; 250 / 300 cycle Power frequency magnetic eld IEC 61000-4-8 30 A/m 50 Hz / 60 Hz 30 A/m 50 Hz / 60 Hz Conduced RF IEC61000-4-6 3 V 0,15 MHz 80 MHz 6 V in ISM and amateur radio bands between 0,15 MHz and 80 MHz 80% AM at 1 kHz 3 V 0,15 MHz 80 MHz 6 V in ISM and amateur radio bands between 0,15 MHz and 80 MHz 80% AM at 1 kHz Radiated RF IEC61000-4-3 10 V/m 80 MHz 2,7 GHz 80% AM at 1 kHz 10 V/m 80 MHz 2,7 GHz 80% AM at 1 kHz NOTE U T is the a.c. mains voltage prior to application of the test level. 26 EMC GUIDANCE FCC Statement Table 3 FCC ID: OU9TMB2092-G Caution: The user is cautioned that changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Radiation Exposure Statement:
To maintain compliance with FCCs RF Exposure guidelines, this equipment should be installed and operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna. Guidance and manufacturers declaration - electromagnetic Immunity Radiated RF Test IEC61000-4-3 Frequency
(MHz) Band
(MHz) Service Modulation Distance(m) Maximum Power
(W) IEC 60601-1-2 Test Level
(V/m) Compliance level
(V/m) 385 380-390 modulation 1.8 0.3 27 27
(Test specications for ENCLOSURE PORT IMMUNITY to RF wireless communicati-
ons equipment) 710 745 780 810 930 1720 1845 1970 TETRA 400 Pulse 18 Hz GMRS 460, FRS 460 FM 5k Hz deviation 1 kHz sine LTE Band Pulse 13, 17 217 Hz Pulse 18 Hz GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 GSM 1800;
CDMA 1900;
3, 4,25;
UMTS Bluetooth, WLAN, 802.11 b/g/n, RFID 2450, LTE Band 7 450 430-470 2 0.3 28 28 704-787 modulation 0.2 0.3 9 9 870 800-960 modulation 2 0.3 28 28 1700-
1990 GSM 1900;
Pulse DECT;
modulation LTE Band 1, 217 Hz 2 0.3 28 28 2450 2400-
2570 Pulse modulation 217 Hz 2 0.3 28 28 5240 5500 5785 5100-
5800 WLAN Pulse 802.11 modulation a/n 217 Hz 0.2 0.3 9 9 527 28