all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manuals | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 3.83 MiB | June 30 2022 | |||
1 |
|
User Manual2 | Users Manual | 2.25 MiB | June 30 2022 | |||
1 |
|
Internal Photos | Internal Photos | 3.46 MiB | June 30 2022 | |||
1 |
|
External Photos | External Photos | 3.59 MiB | June 30 2022 | |||
1 |
|
LABEL | ID Label/Location Info | 313.79 KiB | June 30 2022 | |||
1 |
|
Agent Authorization Rev 1.0 | Cover Letter(s) | 16.98 KiB | June 30 2022 | |||
1 | Block | Block Diagram | June 30 2022 | confidential | ||||
1 |
|
FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 17.37 KiB | June 30 2022 | |||
1 |
|
Model Difference | Cover Letter(s) | 4.24 MiB | June 30 2022 | |||
1 | OP | Operational Description | June 30 2022 | confidential | ||||
1 | SCH | Schematics | June 30 2022 | confidential | ||||
1 |
|
Test Setup photos | Test Setup Photos | 232.11 KiB | June 30 2022 | |||
1 |
|
Test peport | Test Report | 5.87 MiB | June 30 2022 |
1 | User Manual | Users Manual | 3.83 MiB | June 30 2022 |
IP camera tester User Manual V01.00 Thank you for purchasing the IP camera tester. Please read the manual before using the IP camera For using the IP camera tester safely, please first read theSafety Informationcarefully in the tester and use properly. manual. The manual should be kept well in case of reference. Keep the S/N label for after-sale service within warranty period. Product without S/N label will be charged for repair service. If there is any question or problem while using the IP camera tester, or damages occurred on the product, please contact our technical Department. Content 1. Safety information ................................................................................................................................... 1 2. IP Camera Tester Introduction ................................................................................................................ 2 2.1 General ........................................................................................................................................... 2 2.2 Packing list ..................................................................................................................................... 3 2.3 Function interface .......................................................................................................................... 4 3. Operation ................................................................................................................................................. 7 3.1 Installing the Battery ..................................................................................................................... 7 3.2 Instrument connection ................................................................................................................... 8 3.2.1 IP camera connection ......................................................................................................... 8 3.2.2 Analog camera connection ................................................................................................. 9 3.2.3 HD Coaxial camera connection ........................................................................................ 10 3.2.4 HDMI IN .......................................................................................................................... 10 3.2.5 HDMI output .................................................................................................................... 11 3.3 OSD menu ................................................................................................................................... 11 3.3.1 Drop-down Menu ............................................................................................................. 11 3.3.2 Short cut-menu ................................................................................................................. 12 3.3.3 Screen capture ................................................................................................................... 13 3.3.4 Link monitor ..................................................................................................................... 13 3.3.5 TesterPlay ......................................................................................................................... 15 3.3.6 IP discovery ................................................................................................................... 16 3.3.7 IPC Test pro ...................................................................................................................... 17 3.3.8 Rapid ONVIF test ............................................................................................................. 18 3.3.9 NON ONVIF .................................................................................................................... 30 3.3.10 HDMI IN ( *Optional )................................................................................................ 32 3.3.11 Analog camera test ......................................................................................................... 35 3.3.12 Color-bar generator (TV OUT) ...................................................................................... 43 3.3.13 AutoHD ( *Optional ) ..................................................................................................... 44 3.3.14 HD Coaxial & Analog level test ( *Optional ) ............................................................... 44 3.3.15 SDI Camera Test ( *Optional ) .................................................................................... 46 3.3.16 CVI camera test ( *Optional ) ..................................................................................... 47 3.3.17 TVI camera test ( *Optional ) ...................................................................................... 54 3.3.18 AHD camera test ( *Optional ) .................................................................................... 56 3.3.19 NET TOOL PRO ............................................................................................................ 57 1IP address scan ................................................................................................................. 57 2PING Test ........................................................................................................................ 58 3Network test (Ethernet bandwidth test) ........................................................................... 58 4Port Flashing .................................................................................................................... 61 5DHCP server .................................................................................................................... 62 6Trace route ....................................................................................................................... 63 7Link monitor .................................................................................................................... 63 3.3.20 PoE power / DC12V 3A and DC 5V 2A USB power output ........................................ 64 3.3.21 DC 24V 2A power output............................................................................................... 65 3.3.22 Cable Test ....................................................................................................................... 66 3.3.23 RJ45 cable TDR test ....................................................................................................... 67 3.3.24 Cable Tracer ( *Optional ) ......................................................................................... 69 3.3.25 TDR cable test ( *Optional ) ....................................................................................... 71 3.3.26 BNC attenuation test ( *Optional ) ................................................................................. 74 3.3.27 PoE Voltage test ............................................................................................................. 75 3.3.28 12V power input test ...................................................................................................... 76 3.3.29 Digital Multi-meter ( *Optional ) ................................................................................ 77 3.3.30 Optical power meter ( *Optional ) .............................................................................. 85 3.3.31 Visual Fault Locator ( *Optional ) .............................................................................. 87 3.3.32 Audio Record .................................................................................................................. 88 3.3.33 Data monitor ................................................................................................................... 88 3.3.34 Audio player ................................................................................................................... 89 3.3.35 Media Player ................................................................................................................... 89 3.3.36 RTSP Player ................................................................................................................... 90 3.3.37 Hik test tool .................................................................................................................... 91 3.3.38 Dahua test tool ................................................................................................................ 95 3.3.39 Update ........................................................................................................................... 100 3.3.40 Office ............................................................................................................................ 101 3.3.41 LED Flashlight ............................................................................................................. 102 3.3.42 Browser ......................................................................................................................... 102 3.3.43 Notepad ......................................................................................................................... 103 3.3.44 System Setting .............................................................................................................. 104 3.3.45 File explorer .................................................................................................................. 108 3.3.46 Audio test ...................................................................................................................... 110 4. Specifications ....................................................................................................................................... 110 4.1 General Specifications ............................................................................................................... 110 4.2 Multi-meter specifications ......................................................................................................... 114 4.3 Optical power meter specifications ........................................................................................... 116 4.4 Visual fault locator specifications ............................................................................................. 117 1. Safety information The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital, gas station etc. To prevent the functional decline or failure, the product should not be sprinkled or damped. The exposed part of the tester should not be touched by the dust and liquid. During transportation and use, it is highly recommended to avoid the violent collision and vibration of the tester, lest damaging components and causing failure. Don't leave the tester alone while charging and recharging. If the battery is found severely hot, the tester should be powered off from the electric source at once. The tester should not be charged over 8 hours. Don't use the tester where the humidity is high. Once the tester is damp, power off immediately and move away other connected cables. The tester should not be used in the environment with the flammable gas. Do not disassemble the instrument since no component inside can be repaired by the user. If the disassembly is necessary indeed, please contact with the technician of our company. The instrument should not be used under the environment with strong electromagnetic interference. Don't touch the tester with wet hands or waterish things. Don't use the detergent to clean and the dry cloth is suggested to use. If the dirt is not easy to remove, the soft cloth with water or neutral detergent can be used. But the cloth should be tweaked sufficiently. About Digital Multi-meter Before using, you must select the right input jack, function and range. Never exceed the protection limit values indicated in specifications for each range of measurement. When the tester is linked to a measurement circuit, do not touch unused terminals. Do not measure voltage if the voltage on the terminals exceeds 660V above earth ground. At the manual range, when the value scale to be measured is unknown beforehand, set the range Always be careful when working with voltages above 60V DC or 40V AC, keep fingers behind the selector at the highest position. probe barriers while measuring. Page.1. Never connect the meter with any voltage source while the function switch is in the current, resistance, capacitance, diode, continuity, otherwise it will damage the meter. Never perform capacitance measurements unless the capacitor to be measured has been discharged Never measure any of resistance, capacitance, diode or continuity measurements on live circuits. fully. Visual laser sources When you turn on visual laser sources, please don't stare at it, or will damage to eyes When not using it, please turn it off and cover the protective cap. 2. IP Camera Tester Introduction 2.1 General The 7 inch touch screen IP camera monitor is designed for maintenance and installation of IP cameras, analog cameras, 8MP TVI, 8MP CVI, 8MP AHD, 8MP EX-SDI cameras, as well as testing 4K H.264
/4K H.265 camera via mainstream, The 1920x1200 resolution enables it to display network HD cameras and analog cameras in high resolution. The unit supports many ONVIF PTZ and analog PTZ control. The combination of touch screen and key buttons make the IP camera tester very user-friendly. The tester is also a great tool for Ethernet network testing. It can test PoE power voltage, PING, and IP address searching. You can use the blue cable tracer to locate individual connected cables from a bundle of cables. Test LAN cable for proper connection termination. Other functions include providing 25.5W PoE power to your camera, HDMI IN and OUT, CVBS loop test, testing IP and analog at the same time, LED Flashlight, DC 12V 3A, DC 24V 2A, power output and much more. Its portability, user-friendly design and many other functions make the IP tester an essential tool for all installers or technicians. Page.2. 2.2 Packing list 1). Tester 2). Adaptor DC12V 2A 3). Network cable tester 5). BNC cable 6). RS485 cable 9). Output Power cable 10). Audio cable 12). 8GB SD card 13). Safety cord 14). Tool bag 15). Manual 4). Polymer lithium ion battery (7.6V DC 7800mAh) 7). SC, ST connectorOnly for optical power meter 8). Multi-meter test leads one pair of red and black (only for the Multi-meter models) 11). TDR alligator clamp (only for TDR models) Page.3. 2.3 Function interface 1 2 3 4 5 6 7 8 9 Press more than 2 seconds, turn on or off the device, short press to turn on or off the menu display Menu key, press it to call short- menu. 4xzoom the image displays. Far focus: Focus the image faraway Near focus: Focus the image nearby TELE: zoom in the image WIDE: zoom out the image Open/set, Confirm the setting of parameters, open or enlarge the aperture Return/Close: Return or cancel while setting parameters of the menu, close or decrease the aperture Page.4. Upward, set function or add parameter. Tilt the PTZ upward Rightward, select the parameter whose value will be changed. Add the value of the parameter. Pan the PTZ right downward Downward, set function or reduce the value of the parameter. Tilt the PTZ Leftward, select the parameter whose value will be changed Confirm key,(Long press it to capture screen interface) Return/Close : Return or cancel while setting parameters of the menu, close or decrease the aperture Multimeter interface (Optional) The charge indicator: it lights red while the battery is being charged. As the charging is complete, the indicator turns off automatically The RS485 data transmission indicator: it lights red while the data is being transmitted The data received indicator: it lights red while the data is being received The power indicator: it lights green while the tester is powered on by the adapter Page.5. 10 11 12 13 14 15 16 17 18 19 20 Top interface Bottom interface 21 Visible red laser source emits Interface (Optional) 22 DC12V3A power output, for provisional DC power supply HDMI IN (Optional ) CVBS IN/AHD /TVI/CVI Coaxial interface /BNC interface(AHD /TVI/CVI (Optional) ) Video signal outputBNC interface/ cable tracer interface 23 24 25 26 27 28 29 Optical power meter interface (Optional) LED lamp RS485 Interface: RS485communication for the PTZ HD-SDI/EX-SDI input (BNC interface) ( Optional) 30 TDR cable test interface (Optional) Page.6. 31 HDMI output interface 32 Micro SD card moveable,(comes with 8GB, supports up to 32GB) UTP cable port: UTP cable tester port/ Cable tracer port PSE power sourcing equipment. Tests PoE voltage/LAN test port PoE power supply output or LAN test port (Using test PoE or non-PoE IP camera) 33 34 35 37 38 39 40 36 Microphone USB 5V 2A power output, transmit data DC 12V 2A charging interface. DC 24V 2A output Audio input/Audio output and earphone interface. 3. Operation 3.1 Installing the Battery The tester has built-in lithium ion polymer rechargeable battery. The battery cable inside battery cabin should be disconnected for safety during transportation!
Prior to the use of the instrument, the battery cables inside the battery cabin should be well connected. Usually it doesn't need to disconnect the cable at the normal use Pressing the key continuously can power on or off the tester. Notice: Please use the original adaptor and connected cable of the device!
When the battery icon is full or the charge indicator turns off automatically, indicate the battery charging is completed. Notice: When the Charge Indicator turns off, the battery is approximately 90% charged. The charging time can be extended for about 1 hour and the charging time within 12 hours will not damage the battery. Page.7. Notice: Press the key several seconds to restore the default settings when the instrument works abnormally. Multi-meter: the red and black multi-meter pen must insert the corresponding port. Warnings: Instrument communication port is not permitted access circuit voltage over 6V, otherwise damage the tester. Warnings: Not allow insert multi-meter pen in the current terminal to measure voltage. 3.2 Instrument connection 3.2.1 IP camera connection Power an IP camera with an independent power supply, then connect the IP camera to the IPC tester's LAN port, if the link indicator of the tester's LAN port is green and the data indicator flickers, it means the IP camera and the IPC tester are communicating. If the two indicators don't flicker, check if the IP camera is powered on or the network cable is not functioning properly. Note: 1) If the IP camera requires PoE power, then connect the IP camera to the IP tester's LAN port . The tester will supply PoE Power for the IP camera. Click the icon POE to turn the PoE Power off or Page.8. on. 2) If use the tester's menu to turn off the tester's PoE power supply, the PoE switch and the power sourcing equipment are allowed to connect to the tester's PSE port, and the PoE power will be supplied to the IP camera by the tester's LAN port. On this condition, the tester cannot receive data from IP camera, but the computer connected to the PoE switch can receive the data via the the tester. Warning: PoE switch or PSE power sourcing equipment only can be connected to tester "PSE IN" port, otherwise will damage the tester. 3.2.2 Analog camera connection 1) Connect the camera's video output to the IP tester's VIDEO IN. The image will display on the tester after pushing the PTZ icon. 2) CCTV IP Tester "VIDEO OUT" interface connect to the Video input of monitor and optical video transmitter and receiver, the image display on the tester and monitor. 3) Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface.(Note:
positive and negative connection of the cable) Page.9. 3.2.3 HD Coaxial camera connection
* SDI, CVI, TVI, AHD camera are classified as HD coaxial cameras. Hereby the following instruction of how to connect SDI camera to the tester is also applied to CVI, TVI, and AHD camera. 1) Connect the SDI camera's video output to the IP tester's "SDI IN" interface, the image will display on the tester. The tester only come with SDI input interface. There is no SDI output interface. 2) Connect the SDI camera or the speed dome RS485 controller cable to the tester RS485 interface. 3.2.4 HDMI IN DVR or other device's HDMI out port connect to tester's HDMI in port, the meter will display input image. Page.10. 3.2.5 HDMI output The built in HDMI output port can output live video from an analog or IP camera, recorded files, media files and images to HDTV monitors. Connect an HDMI cable from the IP tester to an HDTV monitor at any time. It supports up to 1080P resolution. 3.3 OSD menu Press the key 2 seconds to turn on Press the key again to turn off tester reset. 3.3.1 Drop-down Menu short press the key to enter sleep mode, press it again to test. If tester works abnormally and cannot be turned off, Press the key several seconds to turn off, the Press and slide at right top right corner twice to open shortcut menu. The shortcut menu includes POE power output, IP settings, Wi-Fi, HDMI IN, CVBS, Video OUT, LAN, Brightness, settings etc. HDMI: Click HDMI IN to enter, In HDMI IN mode, it can converter test from analog to digital with dual test window IP & HDMI in or Analog & HDMI in. CVBS: Click icon "CVBS"to enter, you can test IP and analog camera at the same time. TV OUT: Click TV OUT to enter floating window, connecting the BNC cable to tester and appears analog video monitor interface, it can test circuit and BNC cable whether normal. LAN: Display network port or WIFI connection real-time upload and download speeds and other Page.11. network parameters. Settings: Enter settings interface. IP: Enter IP Settings interface. POE power output: Turn on or off the tester "PoE power" app. 3.3.2 Short cut-menu You can call shortcut menu by press tester's "menu" key, you can self- define shortcut -menu. Press the key , you can turn on it, and switch functions, then press to enter app, tap other area on the screen, to exit the menu. You can long press any app in the all applications list, it will auto move to shortcut menu . If delete any app in the shortcut menu, please select a app and press several seconds, it will be deleted. Page.12. 3.3.3 Screen capture Long press the key "enter", can capture screen interface and save it in any time. You can go file management to view "file Explorer sdcard- PicturesScreenshots". 3.3.4 Link monitor Tap icon "Link Monitoring" at left corner on the screen, to enter. It can detect instrument port rate 10/100/1000M, signal quality detection, upload and download speed, etc. in real time. It can be used to detect whether the network video access bandwidth of devices such as NVR is normal. Page.13. When using a four-core cable to connect to a Gigabit device, would prompt "the link limited". Advanced link monitor It is for monitoring CVBS loop, Ethernet statistics, error frame statistics, frame length etc Page.14. 3.3.5 TesterPlay Mobile screen projection (Only for android version) The meter creates WIFI hotspot, connect mobile phone to the tester's WIFI hotspot, or the tester and mobile phone connect the same Wi-fi network. Download and install Remote control app to mobile phone, Tap icon " ", select "TesterPlay" app, Click "Start" will create the RTSP URL. Mobile phone enter "Remote control" app, please click "Auto search IP" to search remote host IP, then click
"Play" to display the real-time image and control IPC Tester. If cant find the IP address, can click "Manually search IP", and input tester's rtsp url to remote host IP, such as 192.168.0.186, then click "Play". Please contract supplier for Remote control APP. PC screen projection:
Install VLC player in the PC, turn on the VLC player "Media - Open Network Streaming", and input the RTSP address of on the top instrument two-dimensional code, click "play" to view the screen real-time projection. Page.15. Page.16. 3.3.6 IP discovery Press IP discovery , tester auto-scan the whole network segment IP, as well as auto-modify the tester's IP to the same network segment with the scanned camera's IP. Local IP: Tester's IP address, Tester can auto-modify the tester's IP to the same network segment with the scanned camera's IP Discovery IP: Connected tester equipment's IP address. If the camera connected to the tester directly, tester will display the camera's IP address, if tester connects to Local Area Network, it displays the current IP address. Temp IIP: After searching IP address, the modified tester's IP address will not be saved, if you do not select "Temp IP" the modified tester's IP address will auto-save after searching. Start: PING function, Click "Start", can PING camera's IP Applicability: Using IP discovery app, you don't need to know the first two digits of camera's IP address, it can auto-scan the whole network segment IP, and auto-modify tester's IP address, greatly Rapid ONVIF: Rapid ONVIF Quick link NON ONVIF: NON ONVIF Quick link improved engineering efficiency . 3.3.7 IPC Test pro Camera test often need to open multiple apps, "IPC TEST PRO" app, using new technology and combine multiple functions to one APP, it can increase efficiency. Page.17. Support multi-segment IP address scan, can visual display camera manufacturer, click IP address to Application:
play the image. Connect IP camera, can supply the power to PoE camera. Real-time display network port connection status. By one key to connect camera test tool, browser can login and configure camera. Batch activate Hikvision and Dahua cameras. 3.3.8 Rapid ONVIF test Rapid ONVIF can display 4K H.265/H.264 camera image by tester mainstream, one key to activate Hikvision camera. Press enter Rapid ONVIF function, the meter auto scan all ONVIF cameras in different network segments. It lists cameras name and IP address on the Left of screen. Tester can auto login camera and display camera image. Factory default use admin password to auto login, if you modified the password, then default use the modified password to log in. If you select ONVIF Rapid mode, the meter automatically scan different network segments for ONVIF cameras. It lists the camera name and IP address on the Device List. Tester can auto login camera and Page.18. display camera image. Click the button "Refresh", tester will scan the ONVIF camera again. Click the newly displayed ONVIF camera on the "Device List". The tester will show the IP camera's relative information and settings. Activate HIKVISION Camera: When connected inactivated HIKVISION Camera, tester can auto recognized, and prompt "The camera have not been activated, activated now?", click "OK" to start activate . Pop-up settings menu when click the "ONVIF setting" icon in the upper left corner. Page.19. Page.20. Cross network scan: After open this function, enter "Setting - IP Settings - Advanced" to add other network segments IP, Rapid ONVIF function can across network segments to scan camera's IP. Auto Login: After open this function, tester can auto login camera and display camera image. (The login password is the same with last time, the first time using password is the default password
"admin") Video transmission protocol: UTP and TCP protocol. Open password cracker: Cracks password of cameras. View manual: Open Manual. Restore Defaults settings: Revert "Rapid ONVIF" to default settings. OK: Save the modified parameters. Click "MENU" icon to open camera setting. While in the "Live video" menu, click "Video Menu" at the top right of the image to access the following tools: Snapshot, Record, Photo, Playback, PTZ and Settings. Page.21. ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move. Tap the left side of the image to move left, right to go right, up to go up and down to go down. Compatible IP PTZ cameras will rotate accordingly. PTZ rotation direction is displayed on top left corner of the image. IP camera video settings: Click "Video Set" to enter the IP camera's encoder and resolution settings. Make the desired changes and click "OK" to save. Page.22. Image setting: Click "Imaging Set" to adjust image brightness, saturation, contrast, sharpness and backlight compensation mode. Profiles: Click "profiles", can view video streaming current configuration files, as well as switch between Major stream and minor stream. Preview pictures: Quickly preview and zoom in or out pictures, automatically and manual refresh. Identification: Click "Identification" to view information of the camera. Page.23. Time set: Click "Time set", Select "Manual set" to set up the time of camera. Maintenance: For camera software reset or restore to factory settings. User Set: Modify camera user name, password etc parameters. Network setting: Click "Network Set" to change the IP address. Some cameras cannot support change IP address, so there is no change after saving. Zoom in image: Press the key to enter the zoom mode. Press it again to exit zoom mode.When the image is enlarged tap left, right, up or down on the image to move the whole image on the screen When the image is enlarged, if not operate on touch screen, it can operate by the keyboard, press the key to zoon in, press the key to zoom out, press upward and downward key to move image. If it is network video input to the tester, as the tester supports resolution up to 1080p, the input image will be very clear after it is enlarged. This is greatly helpful for the installers to ensure the IP camera's video coverage and decide the IP camera's install site. Page.24. Image can only be enlarged on SD mode (The icon "ONVIF" is SD mode.) Select relative function on the bottom Toolbar to operate, "Snapshot" , "Record", "Photos",
"Video playback", "Storage set", "PTZ control" etc. Snapshot: Click bottom "snapshot" to screenshot the image and store it to SD card. If select manual storage, appears dialog box "Input Name", user-defined the files name(by Chinese character, English letter or digit ) to save in SD card, if select "Auto- storage", the tester auto stores the files after snapshot. Record: When you click bottom the "Record" icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the "Stop" icon to stop recording and save the video file to the SD card. Playback: Click the "Playback" icon to view saved videos. Double click the video you want to play. Click to return to the last menu. Page.25. To rename or delete a photo, click and hold on the file until this screen appears:
OSD Menu: Select OSD and popup the OSD menu. include time, channel name and other optional items. After channel selecting, you can edit the channel name, modify the display position, and switch the font size. Select "default location" in "content location" is without modification. Select "Customization" to arbitrarily adjust the channel name and display location. Click "OK" and the effects will appear. Press return key or click any area of the screen to return to the upper layer of the interface. Page.26. Video files can play in the Video player on the main menu. Set preset position: Move the camera to preset position, enter the preset number on the Bottom right PTZ corner to complete position preset. Call the preset position: Select the preset number on the left, click "Call" to call preset. PTZ Speed set: Horizontal and Vertical Speed set. Page.27. Page.28. RTSP: Get RTSP address of the current camera Doc: Auto generate test reports document of camera, click "generate document". Click Preview to view the report document. Enter the camera test information, click "Generate Document" to complete the report. Page.29. Click "Doc" menu again, you can preview the report document. Icons description: The description of function icons on the bottom toolbar. 3.3.9 NON ONVIF Display image from the 4K H.265 camera by mainstream Click icon to enter IP camera test Note: Currently, the IPC Test App only supports some brands' specific IP cameras, these include specific models made by ACTI, AXIS, Dahua, Hikvision, Samsung, and many more. If the camera is not fully integrated, please use the ONVIF or RTSP apps. IPC test interface Local IP: This is the tester's IP address. Click "Edit" to enter "IP setting" and change the tester's IP address settings. integrated IP camera. IP camera type: Click on the IP Camera type to select the Manufacturer and model number of the
"Manual": Click IP camera type, list Honeywell, Kodak,Tiandy, Aipu-waton, ACTi, WoshiDA IP camera etc. If the brand has offered official original protocols, pls select camera type, input IP camera address, user name and password, click "official" to enter the camera image display interface(Currently, only support DAHUA official protocols ) Page.30. Page.31. Stream code: When test camera via RTSP, you can select mainstream or sub stream to test (if camera's RTSP have not been start or without, it will tip "auto match fail, please switch to manually selecting". IP Camera's IP: Enter the IP camera's IP address manually or click "Search" to auto-scan for the IP camera's IP address. It is better to directly connect the IP camera to the tester so the search results will only display the camera's IP address. If the tester is connected to a PoE switch, it will find and display several IP address. IPC User Name: Enter IP camera's user name. IPC Password: Enter IP camera's login password. IPC Port: When you select the IP camera type, it will default the camera's port number and doesn't need to be changed. After all settings are completed, click "Enter" to view the live video. If IP address setting has error or IP camera is not connected.. The tester prompts "Network Error"
Click to quit from image display and return to IP camera test interface. Once you are viewing video on the IPC Test app, you will see the "Video Menu" icon on the top right. This button will give you access to Snapshot, Record, Photo, Playback, PTZ, and Set. Please refer to the ONVIF section to use these functions. 3.3.10 HDMI IN ( *Optional ) HDMI in HD signal test, Tap icon " "to enter When tester receives HDMI in image, the top tool bar shows the resolution of this image. You can select "resolution" to set resolution in the setting menu. Tap screen by twice, full image display. Support resolution below 720480p /720576p /1280720p /19201080p /1024768p/12801024p /1280900p /1440900p Page.32. Click the icon "Snapshot", when the video in, to take a picture and save the current video frame in the
(1) Snapshot SD card as JPEG file. If the unit is set to the manual mode an "Input Name" pop up box will appear and you can enter a title for the snapshot. If the unit is set up to automatically set file names, this box will not pop up.
(2) Video record When you click the "Record" icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the "Record"
Page.33. icon again to stop recording and save the video file to the SD card. if select manual storage, before recording begins, appears dialog box "Input Name", user-defined the files name(by Chinese character, English letter or digit) to store in SD card, tester will hereby store the files in SD card after recording. if select "Auto-storage", tester will auto store the files in SD card after Click the icon "photo" to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return. To rename or delete an image, click and hold on the file until this screen below appears recording.
(3)Photo Click to close and return to PTZ controller. Page.34.
(4) Recorded video playback Click the "Playback" icon to view your recorded videos. Tap on the video file image you want to watch. To rename or delete a video, click and hold on the file until this screen appears:
Video files also can play in the main menu "Video Player". 3.3.11 Analog camera test Analog camera test and PTZ control, click icon to enter Display the input video image, click the top menu bar icon to enter video level meter,
(PEAK level, SYNC level, COLOR BURST measurement) Page.35. Select relative function on the right side Toolbar to operate, functions including "Photos", "Snapshot" ,
"Record", "Playback", "PTZ", "Set". Click , or press to quit. Click the screen twice quickly, can be full zoom in on the touch screen. 1) PTZ controller parameter setting Select and click icon "PTZ", to enter PTZ setting:
Use the up and down arrow keys to move the yellow cursor to the "protocol", set corresponding Protocol and support more than thirty PTZ protocols. Such as Pelco-D, Samsung, Yaan, LiLin, CSR600, A. Protocol Panasonic, Sony-EVI etc. B. Port C. Baud D. Address speed dome address. Click and move to "port" Select the communication port for the PTZ camera controlling (RS485) Move the yellow cursor to "Baud ", Select the baud rate according to baud rate of the PTZ camera.(150/300/600/1200/2400/4800/9600/19200/57600/115200) Set the ID according the ID of PTZ camera (0~254), the setting address data must be consistent the Page.36. E. Pan speed: Set the pan speed of PTZ camera (0~63) F. Tilt speed: Set the tilt speed of PTZ camera (0~63) G. Set preset position (Set PS) Click and select "Set PS", set and save preset position number(1~128). H. Call the preset position (Go PS) Click and select "Set PS", set and save preset position number (1~128), click "sure" to save, Call some special preset number, can call the dome camera menu Check and set the protocols, address, interface and baud, all must be consistent with the dome camera, then the IPC tester can test. After setting the parameter, the tester can control the PTZ and lens To control PTZ by screen touch:
Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ. PTZ Control:
Press the key control the PTZ direction of rotation Press the key or , switch on or turn off the aperture. Press the key or , adjust the focus manually Press the key or , manually adjust the zoom 2) Video and storage setting Click icon "set", to enter and set analog video image brightness, contrast, color saturation, as well as the file storage way after snapshot and recording, support auto-storage and manual storage. When select manual storage, user can name and store the files. Page.37. 3) 4 x zoom image display and Video out When image input, press to enter "zoom", press it again to quit. Using the touch screen to control PTZ camera movement:
Tap left, right, upward or downward on the video image to move the PTZ camera in a desired direction. Stretch two fingers outward or inward on the touch screen to zoom the image in or out. If not use touch screen to operate, press the key to zoom out , press the key to zoom in, press upward and downward key to move the image. For analog video input, as the resolution is 720*480, it is normal that the zoom in image is not Page.38. clear. But for network digital video input, as it supports resolution up to 1280*960, the zoom in image is still very clear. This is very helpful for IP camera installation. Click the icon "Snapshot ", when the video in, to take a picture and save the current video frame in the 4) Snapshot SD card as JPEG file. If the unit is set to the manual mode an "Input Name" pop up box will appear and you can enter a title for the snapshot. If the unit is set up to automatically set file names, this box will not pop up. 5) Video record When you click the "Record" icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the "Record"
icon again to stop recording and save the video file to the SD card. if select manual storage, before recording begins, appears dialog box "Input Name", user-defined the files name(by Chinese character, English letter, or digit) to store in SD card, tester will hereby store the files in SD card after recording. if select "Auto-storage", tester will auto store the files in SD card after recording. Page.39. Page.40.
(6)Photo Click the icon "photo" to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return. To rename or delete an image, click and hold on the file until this screen below appears. Click to close and return to PTZ controller.
(7) Recorded video playback Click the "Playback" icon to view your recorded videos. Tap on the video file image you want to watch. To rename or delete a video, click and hold on the file until this screen appears:
Video files also can play in the main menu "Video Player".
(8) Video level meter Click the icon to enter, the IP camera tester has adopted hardware high-speed sampling and processing technology, can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC levels and COLOR BURST chroma level. When an analog signal is fed into the meter, the tester displays the measurements on the bottom left corner of the screen While in PAL format, the unit will be mV, While in NTSC format, it will be IRE. Page.41. Video signal level 14015IRE NTSC Chroma level( COLOR BURST) 405IRE SYNC signal level 405IRE Video signal level 1000200mV PAL Chroma level( COLOR BURST) 30035mV SYNC signal level 30035mV Video signal PEAK to PEAK level:
For NTSC format, the video signal level is 14015IRE For PAL format, the video signal level is 1000200mV If the level is too low, it will cause the image to lose quality and limit the distance it will travel over cable. If the level is too high, it will distort the image. SYNC level: Tests the amplitude of the video sync pulse to verify if the video level is correct. For NTSC format, the SYNC level is 40 5IRE For PAL format, the SYNC level is 300 35mV If the level is too low, it will cause the image to not frame out properly. If the level is too high, it will lead to a poor quality image. COLOR BURST level: Testing the color burst level will determine if the burst signal is sufficient to trigger the displays color producing circuit. Burst will diminish in amplitude over longer cable runs and can get fall below the threshold for the video display to show a color image. For NTSC format, the Chroma standard level is 40 IRE Page.42. For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will become lighter. If the Chroma level is too high, there will be distortions on the image. If the coaxial cable is too long, it will reduce the chroma level. Image loop test: Test video optical transmitter and receiver and video cable, connect one end to the tester "VIDEO OUT" port, and the other end connected to "VIDEO IN" port, the signal send via
"VIDEO OUT" port, and received via "VIDEO IN" port, If the testing is ok, the tester displays several gradually dwindling photos on the desktop. 3.3.12 Color-bar generator (TV OUT) select "PAL/NTSC" output formats. Click to enter, the tester sends the color bars from the "Video out" port, Click the icon "PAL", Click the selected color-bars, testing image or single bar ( red, green, blue, white or black). Double click to full display on the screen and output, click to return main menu. Application BNC loop test: Tester can send and receive color bar generator through the tester's "video out and video in" port, it is for testing transmission channels, such as video Optical, video cables etc. The tester
"VIDEO OUT" port to connect optical terminal's sending port, and "VIDEO IN" port to optical terminal's connect its receiving port. Page.43. A. When maintaining the dome camera, the tester sends out the color bar by its BNC output to the monitor at the monitoring center. If the monitor receive the color bar, it means the video transmit channel works normally. Meanwhile on the basis of the received color bar, the monitoring center can judge if transmission has loss or interference. B. The tester sends out the pure color bar (such as white and black color), to test the monitor whether has bright or black dots C. The tester sends out video signal image to test if the image received by the monitor has excursion. 3.3.13 AutoHD ( *Optional ) Auto-recognize the resolution and Auto-display the image of the connected camera. Support coaxial PT Z control and call OSD menu, support up to 8MP TVI/CVI/AHD and CVBS cameras. 3.3.14 HD Coaxial & Analog level test ( *Optional ) Through hardware high-speed sampling and processing technology, accurately measure video peak level, sync level and burst level. It is used for level measurement of HD coaxial cameras, judge whether the working image of the camera and the image after attenuation by BNC cable transmission are normal, quickly detect and eliminate faults. Page.44. Page.45. Image display: Select the camera type, no need to select the resolution, click the camera icon, can browse the camera image directly. Level Meter Test: Need to select the camera type and resolution, click "test" to test the level Color bar generation: Click"CVBS", quickly enter color bar generation app Test ResultThe percentage and signal grid of the level value. compared with the reference value. When the value is lower than the threshold, the background color will be grayed and appear the warning icon. Different camera and cable lengths, different level value. Reference value: The normal value at this resolution, it is used to reference and compare test results, click "value" to modify. click "value" to modify. Threshold: Critical value at this resolution. Lower this value, will appear image noise on the screen, Reset: Click "Reset" to reset the reference value and threshold. Create documents: The testing report can save customer information, level meter test information, camera information and Instrument information. Page.46. 3.3.15 SDI Camera Test ( *Optional ) SDI camera test, Dome camera test and PTZ control, click icon to enter. Page.47. When tester receives SDI camera image, it will display the image data. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows:
1280x720P 25Hz, 1280x720P 30Hz, 1280x720P 50Hz, 1280x720P 60Hz, 1920x1080P 25Hz 1920x1080P 30Hz, 1920x1080I 50Hz, 1920x1080I 60Hz, EX-SDI: 2560x1440P /25/30FPS, 3840x2160 20/30FPS. monitor. IPC tester's HDMI output port can be use as SDI to HDMI converter, output HD SDI image to HD TV Select relative function on the right side Toolbar to operate, "Snapshot" , "Record", "Photos ",
"Video playback", "PTZ control", "Video Brightness and Storage set", the operation is the same to the video monitor function, please refer to the relevant instructions "3.3.1" in the manual. Click or press to quit. 3.3.16 CVI camera test ( *Optional ) the screen to make the image displayed full screen. The tester supports resolution as follows:
HD CVI camera, CVI dome camera test and PTZ control, click icon to enter When HD CVI signal input, the tester will display the image resolution on the top bar. Double-taps on 1280x720P 25FPS / 1280x720P 30FPS / 1280x720P 50FPS / 1280x720P 60FPS / 1920x1080P 25FPS /
1920x1080P 30FPS/2560x1440P 25FPS/2560x1440P 30FPS/ 2592x1944P 20FPS / 2960x1920P 20FPS / 3840 x 2160P 12.5/15 FPS 1PTZ control 1.1 Coaxial PTZ control
"Port": select coaxial control Click the icon"PTZ"on the right toolbar to do the corresponding setting. Enter PTZ address to perform parameters setting Page.48. Page.49. Operation instructions, please refer to "3.3.1 PTZ (1) Video monitor test"
The PTZ address in the tester must be consistent with the dome camera or decoder, then the IPC tester can test. After setting the parameter, the tester can control the PTZ and lens. To control PTZ by screen touch:
Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ. To control PTZ by key buttons Press arrow keys to control to control the PTZ direction of rotation Set preset position Press the key to switch on or turn off the aperture. Press the key to adjust the focus manually. Press the key to manually adjust the zoom. Setup preset position, move the PTZ camera to the preset position, the Tap it and input preset position number. Tap "Set position" to complete set preset position. Call preset position Tap the preset position:
position. Tap the preset position area, input preset position number. Tap "call position" to complete call preset Page.50. Page.51. 1.2 RS485 control Operation instructions, please refer to "3.3.1 PTZ (1) PTZ control parameters setting". 2Coaxial camera menu setting Tap icon "UTC", select "menu setting" to enter the dome camera menu. Input calling dome camera menu address code, after finishing the parameter settings, you can press the key or click the icon to call the dome camera menu. Press arrow keys to set Page.52.
(3) Snapshot, record, photo viewer and video play back, please refer to "3.3.1 PTZ (1) Video monitor test". Tap "close menu" or press the key " " to close camera menu.
(4) Save setting Click icon "Set" on the right toolbar to enter storage setting. Support auto-storage and manual storage. When select manual storage, user can name and store the files. Page.53. 3.3.17 TVI camera test ( *Optional ) HD TVI camera, TVI dome camera test and PTZ control, Click icon to enter The tester supports resolution as follows:
1280x720P 25FPS / 1280x720P30FPS / 1280x720P 50FPS / 1280x720P 60FPS 1920x1080P 25FPS / 1920x1080P 30FPS / 1920x1080P 50FPS / 1920x1080P 60FPS //2048x1536P 18FPS/2048x1536P 25FPS/2048x1536P 30FPS /2560x1440P 15FPS/2560x1440P 25 FPS/2560x1440P 30FPS/2688x1520P 15FPS/2592x1944P 12.5FPS/2592x1944P 20FPS/3840 x 2160P 12.5/15 FPS Page.54. Coaxial camera menu settings Tap icon "UTC", select "menu setting" to enter the dome camera menu. Input calling dome camera menu address code, after finishing the parameter settings, you can press the key or click the icon to call the dome camera menu. More operation instructions (such as PTZ control, coaxial camera menu setting, snapshot, recording and playback etc), please refer to "3.3.6 CVI camera test". Page.55. 3.3.18 AHD camera test ( *Optional ) AHD camera, AHD dome camera test and PTZ control, Click icon to enter The tester supports resolution as follows:
1280x720P 25,30FPS / 1920x1080P 25FPS / 1920x1080P 30FPS/2048x1536P 18,25FPS/2048x1536P 30FPS /2560x1440P 15 FPS/2560x1440P 25,30 FPS/2592x1944P 12.5,20FPS/3840 x 2160P 15FPS
(1) Coaxial PTZ control
"PTZ" cannot control, please go "PTZ-2" ) UTC control: select "PTZ control or PTZ control-2"(AHD camera has two different order, if select If to coaxial PTZ control the AHD camera, no parameters setting is needed. More operation instructions please refer to "3.3.6 CVI camera test"
Page.56.
1 | User Manual2 | Users Manual | 2.25 MiB | June 30 2022 |
3.3.19 NET TOOL PRO NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP. 1IP address scan Connect the cable to the LAN port. Set your IP address search range by changing the Start and End IP addresses. Click the "Start" button to scan the IP address range. You can also input an IP address in the Port Number Scan to scan for open ports. Page.57. 2PING Test PING is the most conventional network debugging tool, it is used for testing if the connected IP camera or other network equipment's Ethernet port is working normally and the IP address is correct. Connect a network cable to the LAN port and click the icon to open the PING tool. You can set your LOCAL (native) IP address, Remote IP address (e.g. IP camera), Packet count, Packet Size, Packet time and Timeout. Press "Start" to start pinging. If the IP camera or network device is not configured properly or not plugged in, it will say "Destination host unreachable" or "have 100% packet loss". If the tester connects to the device, the send and receive packets will have a 0% packet loss. Application: PING testing is the most conventional network debugging tools. It is used for testing if the connected IP camera or other network equipment's Ethernet port is working normally and the IP address is correct. It's normal that the first data packet will be lost when test start. 3Network test (Ethernet bandwidth test) To use the Network tester, you will need two IP testers. One is used as a Server and the other as a Client. Both devices must be on the same network segment in order to communicate. Click the icon to open the Network Tester app. Page.58. Page.59. When test, need a tester or a computer installed Network Test Software as the Server, the other tester sends packet test. The two testers must be in the same network segment. a). Start the server: Click "Start Server" button to use the tester as a Server. It will display its IP address at the top of the screen. b). Start send packet test: Using the other IP tester, type in the Server's IP address at the top right corner of the screen. This app is used to send packets for network speed testing. Click the "Start" button to send the packets and start testing. Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, to do the mutual testing with the tester. If use computer as the server, the computer IP address is :192.168.0.39 Tester as Client, tester's IP address is:192.168.0.238. The Server and the Client are at the same network segment, but with different IP address. Input Server's IP address 192.168.0.39 in the tester and click
"Start" to test network bandwidth. Page.60. Or use tester as a Server, computer as test Clientselect Client, input tester's IP address to test When use tester as Server, shows results:
4Port Flashing Connect a network cable to the meter's "LAN" port, click the icon to open the Port Flashing app. Click "Start". The IP tester sends a unique signal to make the connected LAN port of the switch flash. If the tester and PoE switch are connected well, the LAN port of POE switch flash at special frequency, If not, no any changes on the LAN port Page.61. The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network Click on the DHCP icon to open the DHCP server app. Select the "Start" check box at the top and make any desired changes to the network settings. Click "Save" to start assigning dynamic IP addresses for IP cameras and other networked devices. Click the "Refresh" button to check your Client list. Application:
connection. 5DHCP server Page.62. 6Trace route It is used to determine path of the IP packet access target. Note: Trace route testing results only for reference, for accurate test route tracking, Please use professional Ethernet tester. Click to enter trace route default is 30 Click "start" to trace the goal address Input tracking IP address or domain name in the Remote Host IP. Set maximum hop count, normally 7Link monitor Click the icon to open the Link Monitor app. This app is used to see if an IP address is occupied by other network devices. This will avoid new address conflicts Click "Add " and enter the desired IP address. To test different network segments, click the "Settings"
icon on the main menu and go to IP Settings and make the desired changes. Once the desired IP addresses are added to the Link Monitor list, click "Start". If the IP address status shows a check mark the IP address is occupied. If the IP address status shows an X the IP address is available. Click "Stop"
to stop the testing Page.63. Page.64. Application:
Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied. 3.3.20 PoE power / DC12V 3A and DC 5V 2A USB power output When the tester is turned on, the DC 12V and DC 5V power output functions are automatically turned on. If the IP tester is turned off, the DC 5V USB can still be used to power an external USB device. To use the PoE Power Output function, click on the icon and change the switch "ON" or "OFF". The IP camera needs to be connected to the LAN port before you turn PoE Power on. If the IP camera Supports PoE, the PoE power is delivered via pins 1, 2, 3, and 6 on the LAN port. The IP tester will display "48V ON" at the top of the screen when the POE power is still on. Note:
1. Don't input power into the "DC12/3A OUTPUT" port. 2. Don't output this DC12V/3A power to the DC12V/IN port of the IP camera tester to avoid destroy 3. The IPC tester power output is close to 3A, if the IP camera's power is over 3A, the tester will auto enter protection mode. Disconnect all the connections of the tester and then connect the tester with 4. Before turning on the PoE power output, please make sure the IP camera supports PoE power. power adaptor to resume the tester. Otherwise it may damage the IP camera. 5. Make sure you plug in your IP camera to the LAN port prior to turning on PoE power 6. Make sure the tester is full charged or more than 80% charged, otherwise the tester will shows
"low power", "not able to supply power". 3.3.21 DC 24V 2A power output The top and the bottom of the "DC24V ON/0W "is power output interface Application:
Power output function is mainly used in the camera field demonstration and testing, meanwhile, for some camera installation sites, if there is no power outlet, the tester can offer temporary power for Page.65. the camera. Notice:
a. Don't input any power into the "DC24V/2A OUTPUT"port of the tester to avoid destroy. Man-made damage is not within our company's warranty b. Don't output this DC24V/2A power to DC12V/ IN port to avoid destroy. otherwise the tester will damage, and man-made damage is not within our company's warranty. c. The IPC tester power output is close to 2A, if the IP camera's power is over 2A, the tester will auto enter protection mode. Disconnect all the connections of the tester and then connect the tester with d. Make sure the tester is full charged or more than 80% charged, otherwise the tester will shows power adaptor to resume the tester.
"low power","not able to supply power"
3.3.22 Cable Test Click icon to enter Test LAN cable or telephone cable. Connect LAN cable or telephone cable with the CCTV tester and cable tester. And then the connecting status, cable type and the sequence of wires as well as the serial number of the cable tester kit will be displayed. The number of the cable tester is 255. Page.66. If need several different number other types cable testers, should pay the additional cost. Cable test Tap "cable test sketch map", pop up Straight-through cable and crossover cable sketch, It is for line sequence reference, when the crystal on the first pressure in the twisted-pair. 3.3.23 RJ45 cable TDR test Connect cable to tester's LAN port, click icon " " to enter RJ45 cable TDR test app. Single test: Test cable status, length and attenuation. Page.67. Repeat test: Continue to test cable status, length and attenuation. Status: After link up, screen display "online", if not link up or open circuit, screen display "open circuit", if cable pair is short circuit, screen display "short circuit". Length: The max test length is 180 meters, when cable is open circuit or short circuit, can test the cable length, if screen display "online", the testing result would be not accurate. Cable quality test: Green is good quality cable, Yellow is Poor quality cable, Red is water poured cable, the attenuation value will be displayed when cable over 10 meters. Advanced Test: Test cable pair status, length, attenuation, reflectivity, impedance, skew and other parameters. Attenuation reflectivity: After link up, if reflectivity value is 0, it is the best quality communication Impedance: After link up, if the impedance value is 100, it is the best quality communication, the Skew: After 1000M link up, when skew value is 0ns, it is the best quality communication, if over 50ns, range is generally in 85-135. will cause a Bit Error Rate in the transmission. Cable sequence diagram:
A straight- through and cross-over cable diagram, the cable sequence display for reference. Page.68. Page.69. Click "Help" to check the instruction of all parameters. 3.3.24 Cable Tracer ( *Optional ) Connect tested cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO OUT) port on the bottom. Click icon to enter, click the Number on the screen to adjust audio type. UTP mode is used for searching the normal network cable or other cables. STP mode is used for searching the shielded network cable. rotation reduce sensitivity. Rotating the switch of cable tracer to turn on. Clockwise rotation increases sensitivity, anticlockwise Cable tracer and Cable tester can be tested at the same time. It is better to judge whether the search network cable is accurate. Connect the other end of the tested network cable to the "UTP" port of cable tracer, the cable sequence, continuity, test box number and network cable type will be displayed on the right side of the meter interface. The "G" indicates the continuity of the shielded network cable. The 1-8 indicators of cable tracer will flash according to the cable sequence. The DIRECT / CROSS /
OTHER three indicator lights display the type of network cable directly. Press the "MUTE" button of cable tracer for 2 seconds. After the "Di" sound, the silent mode is turned on. In the silent mode, can judge cable type according to the indicator light. Press the "MUTE" button again to exit the silent mode. Application It's convenient for people to find out the other end of the cable from the messy cables in security maintenance and network engineering. While searching BNC cable, connect one port of the alligator clips to the copper core or copper net of the BNC cable, the other one to connect the earth wire (barred windows). Page.70. Note: The battery of the cable tracer must according to corresponding positive pole + and negative pole -, otherwise will damage the tester. Note: While the cable tracer tester is receiving the audio signal from the tester, it may be influenced by other signals and make some noise. 3.3.25 TDR cable test ( *Optional ) Note: The testing cable can't be connected to any equipment, otherwise it will damage the tester. Connect Alligator clip cable to the TDR port, and the cable must connect well before testing, otherwise it will influence the accuracy. Built-in BNC cable, network cable, RVV control cable, Telephone line and TVVB cable etc can test. 11 groups user-defined cable can be set.
(1) Curved trajectory 1) Curve result analysis or falls after the smooth curve. Inflection point: The position of break point or short-circuit of the cable, is where curve suddenly rises Short circuit: The curve shows an upward trend after the inflection point Page.71. Open (break point): The curve shows a downward trend after the inflection point
2) Curve operation Zoom: Zoom the curve. Click icon "zoom", tap the curves by two fingers or use virtual keyboard (tap the icon of the screen left edge, to call virtual keyboard) Move: Move curve, click icon "move", and drag the curve to move.
Distance bar: Display the current length, and use the virtual keyboard to move distance bar. Curve thumbnail: Double-click the thumbnail, to restore the scaled curve
(2) Calibration Due to differences in production processes and materials, the cable impedance of different manufacturers may be different, which will lead to large deviations in the test results. The Calibration function can be used at this time. Click "Cable" "Type" to select cable and start testing. One tap on "Start", do one testing. If select built in cable type for testing, click "+" and "-" to adjust cable's wave speed. Page.72. User-defined calibration: Choose the cable 100 meters to 200 meters (more than 50 meters), click
"Cable", "Type" to select user-defined 1 for calibration, 11 groups user-defined can be set. 1. Select user-defined and click "Calibration" to enter test, click "user-defined 1" can define cable name, such as: AiPu BNC-5 2. Click "Cable", "Type" to select cable, and corresponding type, for example, if testing BNC cable, select "BNC", if testing communication cable 75-2, select SYV 75-2. 3. Click "+" or "-" to adjust wave speed, while display length is the same with the actual Length, click
"Save" to save calibration data. It can be used for the same cable testing next time. Page.73. Page.74. Application: TDR test is the use of pulse reflection method, to transmit pulse signal for tested cable, when cable is open circuit or short-circuit, reflected pulse is generated, the tester receives and deals with the reflected wave, measurement results displayed on the screen. TDR can test cable open circuit and short circuit, help engineer quickly find the cable's problem location. It is more convenient and efficient to repair the faulty cable. Note: The TDR reflect signal could be affected by the cable quality cable's not well connected etc to cause the different TDR measurement. The TDR measurement is for reference only. 3.3.26 BNC attenuation test ( *Optional ) Introduction: Through hardware high-speed sampling and processing technology, the coaxial cable transmission attenuation value can be tested in real time, which can be used to detect the attenuation of the coaxial cable through long-distance transmission and the attenuation value of different cables but at the same distance, and can detect the quality of coaxial cable. Test Methods:
1.Connect the two alligator clip cables to the CVBS IN port and CVBS OUT port separately. Two crocodile clips red to red and black to black clip together, then click "calibration" to calibrate it. 2.After calibration, the red clip clips the copper core of the BNC cable, and the black clip clips the outer envelope of the BNC cable. attenuation value will be displayed after connection, as below:
3.Click "Reset", the application will restore factory defaults. 3.3.27 PoE Voltage test Click icon to enter PoE voltage measurement Page.75. Page.76. Connect a network cable from a PoE switch to the IP tester's PSE IN port. Connect an IP camera or other PoE using node to IP tester's LAN port, the PoE voltage and the cable's pin connection status show on the screen. Note: This test if for measuring the voltage being drawn by the PoE node and the IP tester must be between the PoE switch and the PoE node for this test to work. Note: The PoE switch must be connected to the PSE IN port. The powered device such as IP camera or other PoE node must be connected to the LAN port. Note: Do not connect PoE power supply equipment (such as a PoE switch) to the tester's UTP/SCAN port, otherwise it will damage the tester. PSE transmission When PoE / PSE voltage testing, PoE/PSE conntect to the tester's PSE "IN" port, the camera connect to tester's LAN port, tester not only can transmit voltage to supply power for camera, but also transmit data at the same time. as well as the computer connect to the PoE/PSE, it can log in connected tester's PoE camera. 3.3.28 12V power input test Connect 12V power adaptor to tester's charging port, then click icon "PoE" to enter voltage measurement app, screen show the current adaptor input voltage and power. Note: the current 12V input measured power is the battery charging power and the device working power, the measured power will change depending on the different of battery power and backlight brightness. Warning: Not allow connect device with input power over 17V to tester "12V IN" port, otherwise it will damage the machine. 3.3.29 Digital Multi-meter ( *Optional ) Click icon to enter. 1) SYMBOLS:
U: DC Voltage Measuring A: DC Current Measuring Page.77.
: Resistance Measuring
: Diode Testing
U
: AC Voltage Measuring A
: AC Current Measuring
: Continuity Testing
: Capacitance Measuring AC/DC Voltage and current measurement state display Auto- range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative Display the relative measurement value measurement Press the key to change display state 10A socket In 10A current measurement state ,indicate use 10A socket The current measurement value over the range, if in the Auto range state, to Over range switch Auto. 2) OPERATING INSTRUCTION A. DC Voltage Measuring WARNING!
may destroy the inner circuit. You can't input the voltage which more than 660V DC, it's possible to show higher voltage, but it's Pay attention not to get an electric shock when measuring high voltage. a. Connect the black test lead to the "COM " jack and the red test lead to the "V/" jack. b. Select U, enter the DC voltage measurement. c. the tester default Auto range status ,by click "DC auto range" , press the key can select manual range and restore auto range . Manual range: 0.000V 6.600V range 00.00V 66.00V range Page.78. 000.0V 660.0V range 000.0mV 660.0mV rang B. AC Voltage Measuring WARNING!
may destroy the inner circuit. You can't input the voltage which more than 660V AC, it's possible to show higher voltage, but it's Pay attention not to get an electric shock when measuring high voltage. a. Connect the black test lead to the "COM" jack and the red test lead to the "V/" jack. b. select U ~ , enter the AC voltage measurement. C. The tester default Auto range status, by click "AC auto range"
d. Manual range can be select, press the key "NEAR" to restore Auto range eManual range: 0.000V 6.600V range 00.00V 66.00V range 000.0V 660.0V range 000.0mV 660.0mV range C. DC Current Measuring (only manual range ) Shut down the power of the tested circuit, and then connect the meter with the circuit for a. Connect the black test lead to the "COM " jack and the red test lead to the "mA" jack for a maximum of 660mA current. For a maximum of 10A, move the red lead to the 10A jack. b. Select A, enter the DC current measurement, the screen display"DC current ", can select manual cManual range: 0.000mA 6.6mA range Page.79. WARNING!
measurement. range. 00.00mA 66.00mA range 000.0mA 660.0mA range 00.00A 10.00A rangeuse 10A socket d. Select the range to enter current measurement When only the figure "OL" is displayed, it indicates over range situation and the higher range has to When the value scale to be measured is unknown beforehand, set the range selector at the highest The maximum current of mA socket is 660mA, over-current will destroy the fuse, and will damage The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage D. AC Current Measuring (Only Manual range) Shut down the power of the tested circuit, and then connect the meter with the circuit for a. Connect the black test lead to the "COM" jack and the red test lead to the"mA" jack for a maximum of 660mA current. For a maximum of 10A, move the red lead to the 10A jack.
, enter the AC current measurement, manually select Page.80. NOTE:
be selected. position. the meter. the operator. WARNING!
measurement.
b. Select A the range. c. Manual range: 0.000mA 6.600mA range 00.00mA 66.00mA range 000.0mA 660.0mA range 00.00A 10.00A rangeuse 10A socket When only the figure "OL" is displayed, it indicates over range situation and the higher range has to When the value scale to be measured is unknown beforehand, set the range selector at the highest The maximum current of mA socket is 660mA; over-current will destroy the fuse, and will damage The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage Note:
be selected. position. the meter. the operator. In" AC " mode, only can input "AC ", if not, will damage the meter. E. Resistance Measuring WARNING!
When measuring in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have discharged fully. a. Connect the black test lead to the "COM " jack and the red test lead to the "V/" jack. b. Select , enter the measurement the tester default Auto range status, Press the key manually select range, press "NEAR" to restore "Auto range"
Manual range: (Connect the red lead to black leads, will display the measure range) 000.0 660 range 0.000 K 6.600K range Page.81. 00.00 K 66.00K range 000.0 K 660.0K range 0.000 M 6.600M range 00.00 M 66.00M range F. Continuity Testing WARNING!
will sound. G. Diode Testing WARNING!
of circuit. When testing the circuit continuity, be sure that the power of the circuit has been shut down and all capacitors have been discharged fully. a. Connect the black test lead to the "COM" jack and the red test lead to the "V/" jack. b. Select , enter the continuity test, Connect test leads across two point of the circuit under testing. c. If continuity exists (i.e., resistance less than about 50), built-in buzzer The capacitance of a capacitor should be tested separately, should not test in the installation a. Connect the black test lead to the "COM" jack and the red test lead to the "V/" jack. (the red lead anode "+" ) b. Select , enter the diode testing. c. Connect test red lead across to the anode, the black lead to the cathode of the diode under testing. d. Connect test red lead across to the cathode, the black lead to the anode of the diode under testing. e. Tested diode, forward voltage low 30m, there is sound indication, then can finish the testing quickly without view the screen. Page.82. H. Capacitance Measuring WARNING!
capacitance of a capacitor. To avoid electric shock, be sure the capacitors have been discharged fully before measuring the a. Connect the black test lead to the "COM " jack and the red test lead to the "V/ " jack. b. Select "
", enter the capacitance measurement. c. The tester default auto range status, and manual range by press upward and downward key, Auto rang by press the key "NEAR"
Manual range: 0.000nF 6.600nF range 00.00nF 66.00nF range 000.0nF 660.0nF range 0.000uF 6.600F range 00.00uF 66.00F range 000.0uF 660.0F range 0.000mF 6.600mF range 00.00mF 66.00mF range d. Before connect test leads across two sides of the capacitor under measurement, be sure that the capacitor has been discharged fully. Note:
the installation of circuit. pacitance of a capacitor. a. The capacitance of a capacitor should be tested separately, should not test in b. To avoid electric shock, be sure the capacitors have been discharged fully before measuring the ca c. While testing the capacitance of a capacitor to 660uF, the Max time will be 6.6 seconds, if the cap acitor is leaked or damaged, the data can't be read. The tester will be normal after disconnecting the capacitor. Page.83. Manual range and Auto range measurement. When testing, click "Range select" to change the value, click "Auto range" to enter Auto Data hold Relative value measurement Click "Hold data" to enter, the data be hold, the value is green. Press it again to quit. Click "Relative "to enter, the tester Auto-save the data, the displayed new measurement and relative value is red color. Press it again to quit. The hold function and the relative value be combined use, the display value is yellow The meter protection Voltage protection You can't input the voltage which more than 660V AC, it's possible to show higher voltage, but it's may destroy the inner circuit. Resistance, Continuity, Diode, PTC component Protection Wrong input voltage, will Auto enter protection state , It only suitable for short and limit time work. If input voltage over 600V, will damage the meter. mA current fuse range: 250V 1A if the current over the rated range ,fuse will melt to protect the meter .Pls use the same model when Page.84. change the fuse, Pls opens the battery cover to change. Note: 10A socket without fuse protection, if over the current range Wrong using the 10A socket to measure the voltage, will damage the meter. 3.3.30 Optical power meter ( *Optional ) Click icon to enter ,with five wavelength 1625nm,1550nm, 1490nm, 1310nm,1300nm, 850nm, linear or nonlinear optical power display, both for optical power testing and Fiber link loss relative measurement. It is necessary tool for installation and maintenance optical fiber communication, cable television and CCTV security system. Note: Please keep the fiber connector and the dust cap be clean, and clean the detector with the special alcohol. Data hold again to quit. While testing, click "Hold" to data hold, the data will not change. It's convenient to read. Press Relative power value (optical link loss) measurement While testing, set the wavelength for measurement. Click "relative"(difference) to test, the tester Auto save current fiber power value as the base reference value. Input another optical fiber to be measured, Page.85. the displayed new measurement and relative value is red color. Press it again to quit. Data hold and Relative measuring use together, the data is yellow while the function is effect. Page.86. 3.3.31 Visual Fault Locator ( *Optional ) Click icon to enter VFL four status can select"Steady mode", "Evasive 1Hz","Evasive 2Hz"and "Time off". Click button "Steady mode" to enter steady status, click button "Evasive 1Hz" and "Evasive 2Hz", to enter pulse mode, click button "Time off ", VFL is turned off. Timed turn off can select (5 mins, 10 mins, 30 mins, 60 mins and 120 mins). Click "Steady mode", red laser source emits steady, click again to quit. Click icons "Evasive 1Hz"or "Evasive 2Hz" to enter pulse mode, the red laser source is emitted by a certain frequency, press it again to quit Page.87. 3.3.32 Audio Record Connect an audio device to the IP tester's audio input port. Click the icon to enter the Audio Recorder app. Click the red button to stop, and the unit will prompt you to save the recording. 3.3.33 Data monitor Please click icon to enter Click "Setting" to choose the baud rate of RS485, it must be the same as the DVR or the Control keyboard. The DVR or Control keyboard send the code to the tester, if it can be read, the protocol will shown on the upper right, like Pelco D, if not, like P:---
While the tester receives the code, press the key to empty. Though the RS485 port, display the PTZ control code of the multifunctional keyboard or the DVR. Controller can check the status of the RS485 transmission through the code on the display. (The RS485 communication rate must be the same.) Application: Check the RS485 communication states of the video optical transmitter whether normal. Engineer can analyze the protocol and check the data through the displayed code. Page.88. 3.3.34 Audio player Click the icon to enter . The audio player only supports MP3 format Audio files. 3.3.35 Media Player Click the icon to enter The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4, and MKV. The IP tester recorded files can play directly via the Media player. The Media player will automatically display the video files from the SD card. Click on the desired file to play. Click RETURN to exit. To rename or delete an existing file, press the file name for a few seconds until the screen below appears. You can then rename or delete the file by pressing the desired option. Page.89. 3.3.36 RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video. From the main menu, select the "APP Tool" folder and then select the "RTSP Player" to open the app. If the IP camera uses MJPEG, select the RTSP icon. If the IP camera uses H.264, select the "RTSP HD"
icon. Page.90. Local IP: This is the IP testers IP address. RTSP Add: This is where you can manually enter the IP camera's RTSP URL or click on Search to search the network for cameras that use an RTSP stream. IPC Username: Enter the IP camera's user name. IPC Password: Enter the IP camera's password. Once you have entered all the necessary information, select Enter at the bottom left to view the RTSP stream. Note: In the event the IPC tester does not auto detect the RTSP stream, refer to the specific camera manufacturer for the specific RTSP stream URL. you may find this on line with a search of the camera model number and the word RTSP. 3.3.37 Hik test tool Hik test tool app is design for activating and debugging Hikvision camera, can auto-identify inactivated hikvision camera, also can display image from the Hikvision camera. Tap icon to enter 1.Activation: Select left [online detection] to display the "inactivated" camera and click activate. Page.91. Page.92.
"Activation" and "Batch activation" are optional. Auto open ONVIF protocol: After activation, the new HIK cameras click "play, modify the channel name, modify network information, modify user information" any one of to auto open the selected camera ONVIF protocol. Play: Security status shows the "activated" camera. Enter the correct camera password in the right
[password] and click [play] to pop up the "private protocol" or "speed ONVIF" two options. Select the protocol you need to see the camera images. Modify channel name: Clicking "Modify the channel name" will pop up OSD settings, including time, channel name and other optional items. After channel selecting, you can edit the channel name, modify the display position, and switch the font size. Select "default location" in "content location" is without modification. Select "Customization" to arbitrarily adjust the channel name and display location. Click"OK"and the effects will appear. Press return key or click any area of the screen to return to the upper layer of the interface. Modify network information: Support "modify" and "batch modify" camera IP address, subnet mask Page.93. and other parameters modification. Enter a new IP address and subnet mask, the default gateway will be auto modified according to the IP address. Click "OK" to save the changes. Modify user information: Modify the camera's user name and password. Page.94. Factory Reset: Camera factory reset. Page.95. 3.3.38 Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera, it can display image, and modify IP, user name and password etc. Making Dahua camera test more convenient and quickly. Activation: select left [online detection] to display the "inactivated" camera and click activate. Activate and Batch activate are optional, support reserved phone number for resetting password. Page.96. Page.97. Play: When mode display "activated" camera, input correct password, click "Play" poping up "private protocol" and "ONVIF", Select correspond protocol to view the camera image. Modify Channel: Click "Modify Channel", will pop up OSD setting, includes time, channel name,etc Page.98. After selected Channel name, can edit channel name, modify the display position and font size. If select
"Default position" of Content location, then no need to modify. If select "customize", then can modify Channel name and display position, click "OK"to view the image. Click "Back" or "Return" button to return previous interface. Modify Network: Support Modify and batch modify two way, can modify camera IP address, Subnet mask and gateway. Page.99. Input new IP address, need to input password, click "OK" to save the modification Modify user information: Modify camera user name and password, which is onvif, Dahua test tool, IPC TESTE user name and password, not web user name and password. Factory reset setting: Camera will be soft reset, and the device's user name, password and network set be saved. Other settings information is factory reset. 3.3.39 Update Copy the downloaded update file to SD card "update" directory, if no directory, please create one. Click the icon to open the Update menu. Select "Local Update" to update via the SD card or select "Online Update" to check for updates on the internet. If there are applications that need updating, the applications will be displayed on the Page.100. If there are update programs, applications will be listed in the interface, click related applications, update to the latest version. Update online: Before using online update, need enter settings-user management to register first. System update: Connect the Internet to update systems. 3.3.40 Office Quick office app (support excel, word, ppt format) doc. editable Page.101. 3.3.41 LED Flashlight enter It is convenient for the installation or maintenance in the evening or in the dark. Click icon to While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If you don't press the red button to shut off the lamp and press the button to exit the app, the lamp will stay on. Click the Time Setting button to set a timer that will shut off the lamp. 3.3.42 Browser Click icon to enter Type in the camera's IP address and press "Go" to access the IP camera's interface. NOTE: You will not be able to view live video in the web browser. For viewing video, use the IP tester's live camera view Apps The IP camera and IP tester be on the same network segment for the browser to interface with the Page.102. camera. If they are not in the same segment, click the button or press "RETRUN" to exit. Open the "Settings" app from the main menu to change the IP tester's network settings to match those of the IP camera. 3.3.43 Notepad Notepad can be used to record the important testing results, click the key "Save" to save the contents. Notepad can auto record the storage date and time. Please click to view the notepad, all saving contents display. Click each record bar to show the details. Press the record bar for several seconds, prompt whether delete it. Page.103. 3.3.44 System Setting Click icon to enter Language: Select your desired language: English, Chinese, Korean, Russian, Italian, Polish, Spanish, French or Japanese, German,Turkish,etc. Typewriting: You can select typewriting or install other typewriting:
Date/Time: Set the Date/time of the IP tester IP setting: Manually set the IP address, Subnet Mask, Default Gateway and DNS address or select
"Dynamic allocation" to use DHCP. To test multiple network segments, click "Advanced " and then Page.104. click "Add " to enter another IP address for the IP tester. After setting an advanced IP address (refer to the photos above), the unit can test two network segments
(192.168.5.0) and (192.168.1.0) WLAN Net: Turn WiFi off or on by pressing the "Open the wifi" button. Once WiFi is turned on, and click connected WIFI, it will scan for wireless networks in your area. Select and press "WIFI" several seconds, to set static IP address. Page.105. Wi-Fi hotspot: Input "SSID" name and "password", and then click "ok" to create Wi-Fi hotspot. Brightness: Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level SD Card: Displays SD Card Capacity. You can also format the SD card or unmount it before removing FTP server: Once the IP tester connects to a network, a computer can be used to read the SD card files it. via FTP Page.106. Start the FTP server and then input the tester's FTP address in the PC's address bar. This will enable the PC to read, copy and edit the files from the SD card without the use of SD card reader. Version Information: Shows applications version information, if press any apps icon several seconds to uninstall. having to flip the unit itself. Screen display rotation: Click on "Screen Rotation" to flip the IP tester's display 180 degrees. This function is very convenient for the user to connect the LAN cable on the bottom of the unit without PTZ address scan: You can toggle the PTZ Address scan off or on before entering the " PTZ controller" app. This needs to be turned on in order to use the PTZ Scan feature of the PTZ app. Online Registration: Online update need register first, after the tester connect to network, then fill registration information to register. User Feedback: If you have any comments or suggestions for the tester, please connect it to network Page.107. and write your feedback. screen or "NO". Lock Screen: The meter default is not locked. You can choose password Lock screen, pattern Lock Password Lock Screen: Set password, you can input digitals, letters or characters as password, input it again to confirm .when the meter is in standby mode or turn it on, you can input your password to enter. Pattern Lock Screen: Drawing a pattern to lock. While the meter is in standby mode or turn it on, you can input your pattern to enter. Modify Lock screen password, you need input lock password again. Select password Lock screen or pattern Lock screen to reset lock screen password. After reset pattern lock screen, you need to draw a Restore the factory settings: If the tester to restore factory settings, all your personal files and apps new lock pattern. will be removed. 3.3.45 File explorer Click "File" on the top bar tool, can select internal or external storage. Click on the upper right corner Icon"... ". will pop-up menu, you can select other operation or exit. Browse It includes Music, Videos, Pictures, Documents, zip file etc. It is convenient to view and manager. Page.108. FTP server You can choose internal or external SD card. Other operation details, Please refer to FTP settings. Page.109. 3.3.46Audio test tester with the supplied audio cable. You can test the audio input from audio pickup devices by connecting the audio pickup device to the IP 4. Specifications 4.1 General Specifications Model IP Camera Tester*models Optional Display New 7 inch retina touch screen, 1920*1200 resolution Network port 10/100/1000M auto adjust, RJ45, Dual LAN port Built in WIFI, speeds 150M, allows you to connect to a wireless network WIFI and view IP cameras H.265 Mainstream New hardware decoding, 4K H.265/H.264 camera image display by test mainstream testing IP discovery Auto-scan the whole network segment camera IP Search camera quickly, auto log in and display image from the camera, Rapid ONVIF activate Hikvision camera Hik test tool Batch activate Hikvision camera, display image from the camera, modify Page.110. Channel, batch modify IP, user name and password parameters etc. Batch activate Dahua camera, batch modify IP, modify Channel, user name DH test tool and password parameters etc. ONVIF, ONVIF PTZ, Dahua IPC-HFW2100P, Hikvision DS-2CD864-E13, IP camera type Samsung SNZ-5200, Tiandy TD-NC9200S2, Kodak IPC120L, Honeywell HICC-2300T, RTSP Viewer Auto-recognize the resolution and Auto-display the image of the connected AutoHD* (Optional) camera. Support coaxial PTZ control and call OSD menu, support up to 4K HD Coaxial level test* (Optional) SDI video signal test
* (Optional) 8MP TVI/CVI/AHD and CVBS cameras. Through hardware high-speed sampling and processing technology, accurat ely measure video peak level, sync level and burst level. By one key to create testing report. 1 channel HD-SDI/EX-SDI inputBNC interface), resolution support: 720P 60fps, 1080P 60fps, 1080i 60fps, EX-SDI: 2560 x1440P /25/30fps, 3840 x 2160P 20/30 fps, UTC control and call OSD menu 1 channel CVI inputBNC interface, resolution support 720P CVI video signal test *
25/30/50/60fps,1080P 25/30fps, 2560x1440P 25/30fps, 2592x1944 20fps, Optional 2960x1920 20fps, 3840 x 2160 12.5/15 fps. UTC control and call OSD 1 channel TVI inputBNC interfce,resolution support 720P TVI video signal test*
25/30/50/60fps, 1080P 25/30fps, 2048x1536P 18/25/30fps, 2688x1520P Optional 15fps, 2560x1440P 15/25/30fps, 2560x1944P 12.5/20fps, 3840 x 2160 12.5/15 fps, UTC control and call OSD menu 1 channel AHD inputBNC interface,resolution support 720P 25/30fps, AHD video signal test 1080P 25/30fps, 2048x1536P 18/25/30fps, 2560x1440P 15/25/30fps,
*Optional 2560x1944P 12.5/ 20fps, 3840 x 2160P 15 fps, UTC control and call OSD menu menu Analog video test 1 channel BNC Input & 1 channel BNC Output , NTSC/PAL (Auto adapt) Page.111. Video level meter level measurement for CVBS camera. PEAK video signal level, SYNC signal level, COLOR BURST chroma Zoom Image Supports Analog and IP camera image zooming & movement Snapshot, Video Capture current images and record live video as JPG file. Media player will record and playback view photos and playback video HDMI IN HDMI IN, Support 720480P /720576P/1280720P/19201080P
*(Optional)
/1024768P/12801024P /1280900P /1440900P. HDMI output 1 channel HDMI output, supports up to 1080P RJ45 cable TDR test RJ45 cable TDR test and cable quality test, to test cable pair status, length, attenuation reflectivity, impedance, skew and other parameter. 24V 2Apower output Output DC24V/2A power to camera 12V 3A power output Output DC12V/3A power to camera USB 5V power output 5V 2A power output PoE power output 48V PoE power output, Max power 25.5W Screen management number of icons in each page Under normal mode, you can change icons sequence and self-define the Self-define icons, desktop and application interface background, modify Theme interface sliding effect. drop-down menu lock, password lock screen or pattern lock PoE power switch, IP setting, WLAN switch, HDMI IN functions etc screen 1 channel audio signal input and 1 channel audio signal output to connect Audio test headphones PTZ control Color bar generator SupportRS485 control, Baud 600-115200bps, Compatible with more than 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin, Yaan, etc Output one channel PAL/NTSC color bar video signal for testing monitor or video cable.(red, green, blue, white and black color ) Test UTP cable connection status and display on the screen. Read the UTP Cable tester number on the screen Page.112. Captures and analyzes the command data from controlling device, also can Data monitor send hexadecimal NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex NET TOOL PRO Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP. Cable tracer*
Optional Digital Multi-meter
*(Optional) Find a connected cable from a bundle of cables using audio tones PoE /PSE voltage test Measures PoE switch voltage and displays pin configuration AC/DC Voltage, AC/DC current, Resistance, Capacitance, Data hold, Relative measurement, Continuity testing. Testing speed: 3 times/ seconds, Data range -6600+6600. Optical power meter Calibrated Wavelength(nm): 850/1300/1310/1490/1550/1625nm
*(Optional) Power range(dBm): -70+10dBm Visual fault locator
*(Optional) Test fiber's bending and breakage ( SM and MM fiber) TDR cable test BNC cable, network cable, telephone cable, RVV cable and elevator cable,
*(Optional) cat 5/6 cables length and short circuit. measurement range 1.2KM Through hardware high-speed sampling and processing technology, test the BNC coaxial cable transmission attenuation value, detect the transmission quality of BNC cable. DC 12V 2A BNC attenuation test
*(Optional) POWER External power supply Battery Parameter Operation setting Built-in 7.6V Lithium polymer battery, 7800 mAh Rechargeable Fasting charge, after charging 3.5 hours, normal working time 16 hours Capacitive touch screen, OSD menu, select your desired language: English, Chinese, Korean, Russian, Italian or Polish, etc Page.113. Auto off 1-30 (mins) General Working Temperature
-10---+50 Working Humidity 30%-90%
Dimension/Weight 240mm x 154mm x 46mm / 620g 4.2 Multi-meter specifications Counts: -6600+6600 Conversion rate: 3times/s Current modes for clamp meter with ZERO function Isolation: the Multi-meter connector must be isolated with the other connector. DC voltage 6.600V 66.00V 660.0V AC voltage 6.600V 66.00V 660.0V Range Accuracy Resolution 660mV (Manual range) Range 660.0mV (Manual range) Resolution 0.1mV 1mV 10mV 100mV 0.1mV 1mV 10mV 100mV 0.3%+4 Accuracy 1.5%+6 0.8%+6 Page.114. Range Accuracy Resolution Range Accuracy Resolution 1uA 10uA 100uA 10mA 1uA 10uA 100uA 10mA 0.1 1 10 100 1K 10K Resolution Range Resolution Function 660.0 0.1 sound The measurement value less 303,the tester will DC current AC current 6.600mA 66.00mA 660.0mA 10.00A 6.600mA 66.00mA 660.0mA 10.00A Resistance Range 660.0 6.600K 66.00K 660.0K 6.600M 66M Continuity 0.5%+3 1%+5 0.5%+3 1%+5 Accuracy 0.8%+5 0.8%+2 1.2%+5 Page.115. Range Resolution Function Schottky diode:0.15~0.25V 2.0V 1mV rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V Range Accuracy Resolution 0.5%+20 3.5%+8 5%+8 1pF 10pF 100pF 1nF 10nF 100nF 1F 10F 4.3 Optical power meter specifications Measure Range(dBm)
-70+10dBm Wavelength(nm) 850nm,1300nm,1310nm,1490nm,1550nm,1625nm Uncertainly 5%dB(full range,22) InGaAs 3%dB(-10dBm,22) Display Resolution Linear:0.1% ; Nonlinear:0.01dBm Operating Temperature()
-10+50 Page.116. Diode Capacitance 6.600nF 66.00nF 660.0nF 6.600F 66.00F 660.0F 6.600mF 66.00mF Detector Storage Temperature () Connector type
-20+70 FC/PC 4.4 Visual fault locator specifications Laser type Wavelength Calibration LD 650nm Output power 5mWOptional 10mW,20mW Modulation mode CW/1Hz/2Hz Measurement Range 5KMOptional 10-20KM Connector FC/PC exchangeable Working Temperature 10+50 Operating Temperature
-20+70 The data above is only for reference and any change of them will not be informed in advance. For more detailed technical inquiries, please feel free to call the Technical Department of our company. Page.117. FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Statement To maintain compliance with FCC's RF Exposure guidelines, This equipment should be installed and operated with minimum distance of 20cm the radiator your body. This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter.
1 | Agent Authorization Rev 1.0 | Cover Letter(s) | 16.98 KiB | June 30 2022 |
GUANGZHOU WANGLU TECHNOLOGY CO., LTD. Agent Authorization Company: GUANGZHOU WANGLU TECHNOLOGY CO., LTD. Address: 2nd floor, Block C, Inventor Industrial Park, No.2 Ruitai Road, Kaitai Street, Huangpu District, Guangzhou, China Product Name: IP Camera Tester Model Number(s): IPC-9800CLMOVTADHS Plus, IPC-9800 Plus, IPC-9800ADH Plus, IPC-9800CADH Plus, IPC-9800ADHS Plus, IPC-9800CADHS Plus, IPC-9800M Plus, IPC-
9800C Plus, IPC-9800MH Plus, IPC-9800CMADH Plus, IPC-9800MADH Plus, IPC-
9800MADHS Plus, IPC-9800MTADHS Plus, IPC-9800MTADH Plus, IPC-
9800CMADHS Plus, IPC-98OOMOVT Plus, IPC-9800OVTADHS Plus, IPC-
9800MOVTADHS Plus, TP-7000ADH Plus, TP-7000CADH Plus, TP-7000MADH Plus, TP-
7000CMADH Plus, TP-7000ADHS Plus, TP-7000CADHS Plus, TP-7000CMADHS Plus, TP-7000CLMOVTADHS Plus, IPC-7000, IPC-7100, IPC-7100C, IPC-7200, IPC-7000C, IPC-
7300CO, IPC-7300CV, IPC-7300 O, IPC-7300V, IPC-7600 Plus, IPC-7600ADH Plus, IPC-
7600ADHS Plus, IPC-7600CADH Plus, IPC-7600CADHS Plus, IPC-7600COVTADHS Plus, IPC-6000 Plus, IPC-6000 ADH Plus, IPC-6000ADHS Plus, IPC-6000CADH Plus, IPC-
6000CADHS Plus, IPC-6000COVTADHS Plus, MT-5500, MT-5500 PLUS, IPC-5000 Plus, IPC-5100 Plus, IPC-5200 Plus, IPC-5000C Plus, IPC-5100C Plus, IPC-5200C Plus, IPC-
4300 Plus, IPC-4300ADH Plus, IPC-4300ADHS Plus, IPC-4300MADH Plus, IPC-
4300MADHS Plus, IPC-4300CMADH Plus, IPC-4300CMADHS Plus, IPC-
4300CMOVADHS Plus, IPC-3500 Plus, IPC-3500ADH Plus, IPC-3500CM Plus, IPC-
3500CMADH Plus, IPC-5600 Plus, IPC-5600C Plus, IPC-5600R Plus, IPC-5600CR Plus, IPC-5610 Plus, IPC-5610C Plus, IPC-5610R Plus, IPC-5610CR Plus, IPC-5620 Plus, IPC-
5620C Plus, IPC-5620R Plus, IPC-5620CR Plus, HD-3600ADH Plus, HD-3600ADHS Plus, HD-3600MOVTADHS Plus, X4-ADH, X4-ADHS, X4-MADH, X4-CADH, X4-CMADH, X4-
CMADHS, X4-MADHS, X4-CADHS, V6-ADH, V6-ADHS, V6-MADH, V6-CADH, V6-OADH, V6-CMADH, V6-CMADHS, IPC-1900 Plus, IPC-1910 Plus, IPC-1900C Plus, IPC-
1910C Plus, IPC-1800ADH Plus, IPC-1800CADH Plus, IPC-1600ADH Plus, TI-HD9631, TI-
HD9631C, TI-HD9632, TI-HD9632C, TI-HTV9636ADH, TI-HTV9636ADHS, TI-N9618-ADHW, TI-N9618-CADHW, TI-N9651, TI-N9651C, TI-N9652, TI-N9652C, TI-1900, TI-1900-ACT, TI-
9676ADH, TI-9676CADH, TI-9676ADHS, TI-9676CADHS, TI-9676COTADHS, TI-
9676CVTADHS, TM-R1710-8M, TM-R1710-2M, TM-R1410 Product Description: IP Camera Tester We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. declare tha d certificatio ues concern behalf shal at MiCOM L n of equipm ning the app ll have the s Labs Inc. is ment to the r proval applic same effect allowed to f regulatory a cation. Any t as acts of forward all i agencies as and all acts our own. information s required a s carried ou related to t nd to discu ut by MiCOM the approva ss any M Labs on al Sig nature:
Nam me:
Jing Huan ng Sales man nager mpany:
GUANGZH HOU WANG GLU TECH NOLOGY C CO., LTD. Date:
Jun. 28, 20 022 We and issu our Title e:
Com
1 | FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 17.37 KiB | June 30 2022 |
GUANG GZHOU WA ANGLU TEC CHNOLOGY Y CO., LTD D. of Engineeri l Communic Oakland Mills bia, MD 210 ing Techno cations Com s Road 046 logy mmission t; Request f D: 2A7OB-IP for Confiden PC-9800 ntiality Date: Jun. 28, 2022 om It May C nt to the pro uesting the ents from pu Concern, ovisions of t Commissio ublic disclos the Commis on to withho sure indefin ssions rule old the follow nitely. s Title 47 S wing attach Sections 0. hment(s) as 457 and 0 0.459, we al confidentia documents tary informa be harmful to contain det ation in ope o our comp tailed syste ration of the any and wo m and equi e equipmen ould give co pment desc nt. The publ ompetitors a criptions an ic disclosur an unfair ad d are consi re of these d vantage in dered as documents the market. Schema Block D Parts Lis Operatio m atic Diagram iagram st onal Descri ption r understand pondence du ents and thi zation is iss ding that all uring the ce s informatio sued. l measurem ertification re on will be av ment test rep eview proce vailable for ports, FCC ess cannot public revie ID label for be granted ew once the mat and as confiden e grant of eq ntial quipment Office o Federa 7435 O Columb USA Subject FCC ID To Who Pursua are requ docume These d propriet might b It is our corresp docume authoriz Sincere ely, ure:
Signatu Name:
Title: Sa Jing Huang g ales manag ger
1 | Model Difference | Cover Letter(s) | 4.24 MiB | June 30 2022 |
Model Difference Declaration To Whom It May Concern, We, GUANGZHOU WANGLU TECHNOLOGY CO., LTD.
(IP Camera Tester) Trademark:N/A; Model Number:IPC-9800CLMOVTADHS Plus, IPC-9800 Plus, IPC-9800ADH Plus, IPC-9800CADH Plus, IPC-9800ADHS Plus, IPC-9800CADHS Plus, IPC-9800M Plus, IPC-9800C Plus, IPC-9800MH Plus, IPC-9800CMADH Plus, IPC-9800MADH Plus, IPC-9800MADHS Plus, IPC-9800MTADHS Plus, IPC-9800MTADH Plus, IPC-9800CMADHS Plus, IPC-98OOMOVT Plus, IPC-9800OVTADHS Plus, IPC-9800MOVTADHS Plus, TP-7000ADH Plus, TP-7000CADH Plus, TP-7000MADH Plus, TP-7000CMADH Plus, TP-7000ADHS Plus, TP-7000CADHS Plus, TP-7000CMADHS Plus, TP-7000CLMOVTADHS Plus, IPC-7000, IPC-7100, IPC-7100C, IPC-7200, IPC-7000C, IPC-7300CO, IPC-7300CV, IPC-7300 O, IPC-7300V, IPC-7600 Plus, IPC-7600ADH Plus, IPC-7600ADHS Plus, IPC-7600CADH Plus, IPC-7600CADHS Plus, IPC-7600COVTADHS Plus, IPC-6000 Plus, IPC-6000 ADH Plus, IPC-6000ADHS Plus, IPC-6000CADH Plus, IPC-6000CADHS Plus, IPC-6000COVTADHS Plus, MT-5500, MT-5500 PLUS, IPC-5000 Plus, IPC-5100 Plus, IPC-5200 Plus, IPC-5000C Plus, IPC-5100C Plus, IPC-5200C Plus, IPC-4300 Plus, IPC-4300ADH Plus, IPC-4300ADHS Plus, IPC-4300MADH Plus, IPC-4300MADHS Plus, IPC-4300CMADH Plus, IPC-4300CMADHS Plus, IPC-4300CMOVADHS Plus, IPC-3500 Plus, IPC-3500ADH Plus, IPC-3500CM Plus, IPC-3500CMADH Plus, IPC-5600 Plus, IPC-5600C Plus, IPC-5600R Plus, IPC-5600CR Plus, IPC-5610 Plus, IPC-5610C Plus, IPC-5610R Plus, IPC-5610CR Plus, IPC-5620 Plus, IPC-5620C Plus, IPC-5620R Plus, IPC-5620CR Plus, HD-3600ADH Plus, HD-3600ADHS Plus, HD-3600MOVTADHS Plus, X4-ADH, X4-ADHS, X4-
MADH, X4-CADH, X4-CMADH, X4-CMADHS, X4-MADHS, X4-CADHS, V6-ADH, V6-ADHS, V6-
MADH, V6-CADH, V6-OADH, V6-CMADH, V6-CMADHS, IPC-1900 Plus, IPC-1910 Plus, IPC-1900C Plus, IPC-1910C Plus, IPC-1800ADH Plus, IPC-1800CADH Plus, IPC-1600ADH Plus, TI-HD9631, TI-HD9631C, TI-HD9632, TI-HD9632C, TI-HTV9636ADH, TI-HTV9636ADHS, TI-N9618-ADHW, TI-N9618-CADHW, TI-N9651, TI-N9651C, TI-N9652, TI-N9652C, TI-1900, TI-1900-ACT, TI-9676ADH, TI-9676CADH, TI-9676ADHS, TI-9676CADHS, TI-9676COTADHS, TI-9676CVTADHS, TM-R1710-8M, TM-R1710-2M, TM-R1410 ;All models the function, software and electric circuit are the same, only with a product color and model named different for commercial purpose. Test sample model:IPC-9800CLMOVTADHS Plus. Please contact me if you have any question. Name: Jing Huang Date: Jun. 28, 2022 Title: Sales manager Signature of applicant:
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-06-30 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-06-30
|
||||
1 | Applicant's complete, legal business name |
GUANGZHOU WANGLU TECHNOLOGY CO., LTD.
|
||||
1 | FCC Registration Number (FRN) |
0032594053
|
||||
1 | Physical Address |
2nd floor, Block C, Inventor Industrial Park, No.2 Ruitai Road, Kaitai Street, Huangpu District
|
||||
1 |
2nd floor, Block C, Inventor Industrial Park
|
|||||
1 |
Guangzhou, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2A7OB
|
||||
1 | Equipment Product Code |
IPC-9800
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J****** H********
|
||||
1 | Telephone Number |
020-8********
|
||||
1 | Fax Number |
020-8********
|
||||
1 |
s******@wanglu.com.cn
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
GUANGZHOU WANGLU TECHNOLOGY CO., LTD.
|
||||
1 | Physical Address |
China
|
||||
1 |
s******@wanglu.com.cn
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | IP Camera Tester | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen HUAK Testing Technology Co., Ltd.
|
||||
1 | Name |
J****** Z********
|
||||
1 | Telephone Number |
+86-7********
|
||||
1 |
j******@cer-mark.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412.00000000 | 2462.00000000 | 0.0857000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC