ANGLE FINDER INSTRUCTION APPEARANCE Moving blade Level Blister Hanging hole LCD ZERO button Measuring range 0.0 225.0
~
Battery Cover Resolution 0.1 Accuracy 0.3 Battery 3V lithium battery Working temperature 0C ~ + 40C Working humidity 85%RH Temperature of transport & storage -10C ~ +50C Bluetooth protocol 4.0BLE Bluetooth transmission distance 10m Fixing blade Vertical blisters ON/OFF button Bluetoothbutton Function ON/OFF: Short press to power-on or screen-off. Long press to power-off ZERO : zero reset at any position. BLUETOOTH:Short press to send data once after successful connection of Bluetooth. Long press to turn off/on the Bluetooth function. APPLICATION 1Angle measurement in Construction, woodworking, machining, household DIY application 2Conversion between absolute measurement and relative measurement. Large LCD display. Easy operation.vertical and draw lines. Portable and OPERATION INSTRUCTION Absolute Angle Measurement 1Move the moving blade and make it tightly lean on the xed blade. Then press ZERO to reset the device. 2If 13measured angle180, use the top surface of xed blade and bottom edge of moving blade to measure target angle. The value shows on LCD. 3If 180measured angle225, use the bottom surface of xed blade and top edge of moving blade to measure target angle. The value shows on LCD. Relative Angle Measurement 1Adjust the position of xed blade and moving blade to one measure angle(13measured angle180). Press ZERO to reset the device. 2Use the top surface of xed blade and bottom edge of moving blade to measure the other angle
(13measured angle180). The difference between the two angles shows on LCD. 3If 180measured angle225, please refer to the method of absolute angle measurement. Horizontal Measurement Vertical Measurement Trouble shooting Problem Possible cause Solution 1.No display, fuzzy display or disordered display No battery, wrong battery installation or low battery Install battery again or replace battery
* Place xed blade on the measured surface. If the bubble inside the vial stays between the marks on the vial's surface, the measured surface is horizontal.
* Place the bottom side of xed blade tightly on the measured surface. If the bubble inside the vial stays between the marks on the vial's surface, the measured surface is vertical. 2.Flashing digits Low battery Replace battery 3.Erractc or frozen display Internal error Remove battery and replace battery after waiting 1 minute ANGLE FINDER INSTRUCTION
*BATTERY 1 To install or replace battery, push the battery cover and rotate it according to the OPEN indicator by using your middle nger and index nger. Then the cover could be removed.Automatically shuts off after 1 hour inactivity. 2 Replace or install CR2032 3V Lithium Battery. Please make sure the negative pole and positive pole in the right side. 3 Put the battery cover back to the battery case correctly. Push and rotate the battery cover according to the CLOSE indicator. Press by middle nger OPEN indicator 3V CR2032 Lithium Battery Press by middle nger Press by index nger Press by index nger Close indicator FUNCTION INSTRUCTION 1. Automatically shuts off LCD after 5 minutes inactivity. 2. Move the scale or press ON/OFF to turn on LCD while LCD is off. 3. Same ZERO position after LCD turns on again as before LCD shuts off. 4. All data reset automatically after power off. MAINTENANCE 1Not clear the device with organic solvent. Prevent from water and corrosion. 2This is a sensitive precision tool and should be prevented from crash. If there is any abrasion or accident during using, please reset ZERO before a new measurement. Clean the device with damp cloth. 3The device must be stored indoor (temperature -10 C ~+50 C , humidity85%). FCC Caution: The user is cautioned that changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for aClass B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.