TN902--H1147 DE Kurzbetriebsanleitung FR Guide dutilisation rapide EN Quick-Start Guide LED 175 LED 120 60 60 130 M12 200 M12 20...50 cm metal min. 50 cm liquid min. 50 cm ground M6 x 12 Wiring Diagrams 3 2 4 1 Connectors /S2500 3 2 4 1 Connectors /S2501 3 2 4 1 Connectors /S2503 Europe max. 3,5 m USA, China max. 4,0 m M6 x 12
+
1 RD 3 BK Data 4 WH 2 BU Data
+
1 BN 3 BU Data 4 BK 2 WH Data
+
1 BN 3 BU Data 4 WH 2 BK Data UHF-Schreib-Lese-Kpfe TN902-QL-H1147 Weitere Unterlagen Ergnzend zu diesem Dokument finden Sie im Internet unter www.turck.com folgende Unterlagen:
Datenblatt Projektierungshandbuch RFID Inbetriebnahmehandbcher Anwenderhandbcher fr die Software-Tools RDemo und WebConfig Gertezulassungen Zu Ihrer Sicherheit Bestimmungsgeme Verwendung Die Gerte sind fr den Einbau in industrielle Groanlagen und Growerkzeuge bestimmt und fr Anwendungen in der industriellen Automation vorgesehen. Die BL ident-UHF-Schreib-Lese-Kpfe dienen zum berhrungslosen Datenaustausch mit den BL ident-Datentrgern im BL ident-UHF-RFID-System. Durch Einflussgren wie Bauteilto-
leranzen, Einbausituationen, Umgebungsbedingungen und Materialien (insbesondere Metall und Flssigkeiten) knnen die jeweils erreichbaren Schreib-Lese-Abstnde varieren. Darum ist ein Test der Applikation (vor allem beim Lesen und Schreiben in der Bewegung) unbedingt erforderlich. Der Betrieb der Gerte ist nur in Lndern erlaubt, in denen ein Frequenzbereich 902928 MHz fr die Nutzung von passivem UHF-RFID freigegeben ist. Die Gerte drfen nur wie in dieser Anleitung beschrieben verwendet werden. Jede andere Verwendung gilt als nicht bestimmungsgem; fr daraus resultierende Schden bernimmt TURCK keine Haftung. instand halten. Allgemeine Sicherheitshinweise Nur fachlich geschultes Personal darf das Gert montieren, installieren, betreiben und Ein lngerer Aufenthalt im Strahlungsbereich der UHF-Schreib-Lese-Kpfe kann gesund-
heitsschdlich sein. Mindestabstnde zur aktiv ausstrahlenden Flche des Schreib-Lese-
Kopfs einhalten. Region USA/Kanada 4 W EIRP Sicherheitsabstand
> 0,30 m max. zulssige Strahlungsleistung Die Strahlung der UHF-Schreib-Lese-Kpfe kann medizinische Hilfsmittel beeinflussen. Erhhten Abstand zu aktiven Strahlungsquellen bis hin zur maximalen Sendereichweite einhalten. Produktbeschreibung Gertebersicht Siehe Abb. 1 (TN902-Q120L130-H1147) und Abb. 2 (TN902-Q175L200-H1147). Funktionen und Betriebsarten Die UHF-Schreib-Lese-Kpfe TN902- arbeiten mit integrierter Antenne in einem Frequenz-
bereich von 902928 MHz. Mit den Gerten knnen passive UHF-Datentrger im Single- und Multi-Tag-Betrieb ausgelesen und beschrieben werden. Dazu bilden die Gerte eine bertra-
gungszone aus, deren Gre und Ausdehnung u. a. von den verwendeten Datentrgern und den Einsatzbedingungen der Applikation abhngig sind. Die maximalen Schreib-Lese-Abstn-
de sind in den Datenblttern aufgefhrt. Die Gerte lassen sich mit Softwaretools ber einen PC umfassend testen, konfigurieren und parametrieren. Montieren Die Gerte knnen in beliebiger Ausrichtung montiert werden. Montieren Sie das Gert mit dem zugehrigen Befestigungszubehr. Whlen Sie als Minimalabstand zwischen zwei Schreib-Lese-Kpfen mindestens 20 cm, besser ist ein Abstand von 50 cm (Abb. 3). Whlen Sie bei Portal-Konfigurationen (Abb. 4) einen Abstand von mindestens 3,5 m. Halten Sie bei der Montage einen Mindestabstand von 50 cm zwischen Schreib-Lese-Kopf und Boden, Flssigkeiten sowie Metallen ein (Abb. 5). Aufschrauben auf Montageplatte Montieren Sie das Gert gem Abb. 6. Mast- und Rohrmontage Montieren Sie das Gert gem Abb. 7. Montieren mit Befestigungsarm Der Befestigungsarm RH-Q240L280/Q280L640 (Ident-Nr. 7030296) ist nicht im Lieferumfang enthalten. Montieren Sie das Gert gem Abb. 8. Anschlieen GEFAHR Beeinflussung elektrisch gesteuerter medizinischer Hilfsmittel wie Herzschrittmacher Lebensgefahr durch Strung oder Ausfall medizinischer Hilfsmittel Informieren Sie sich, inwiefern die eingesetzte Strahlungsstrke Ihre medizinischen Halten Sie erhhten Abstand zu aktiven Strahlungsquellen bis hin zur maximalen Sende-
reichweite der Strahlungsquelle. Schlieen Sie das Gert ber den M12-Steckverbinder an das BL ident-Interface an. In Betrieb nehmen Nach Anschluss der Leitungen und Aufschalten der Versorgungsspannung geht das Gert automatisch in Betrieb. Ttes de lecture-criture UHF TN902-QL-H1147 Documents supplmentaires Sous www.turck.com vous trouverez les documents suivants, qui contiennent des informations complmentaires au prsent document:
Fiche technique Manuel de dtermination RFID Manuels de mise en service Manuels utilisateur pour les outils logiciels RDemo et WebConfig Homologations appareils Pour votre scurit Application correcte Les appareils sont conus pour une intgration au sein dinstallations et doutils industriels de grandes dimensions et pour des applications dautomatisation industrielle. Les ttes de lecture-criture UHF BL ident servent lchange de donnes sans contact avec les support de donnes BL ident dans le systme RFID-UHD BL ident. En raison de facteurs dinfluence comme les tolrances des composants, les emplacements de montage, les conditions ambiantes et les matriaux (en particulier le mtal et les liquides), les distances accessibles dcriture-de lecture peuvent varier. Voil pourquoi il est indispensable deffectuer un test de lapplication (surtout pour la lecture et lcriture en mouvement). Le fonctionnement des appareils est uniquement autoris dans les pays dans lesquels une plage de frquence de 902-908 MHz est autorise pour lutilisation de RFID-UHD passif. Les appareils peuvent exclusivement tre utiliss conformment aux indications figurant dans cette notice. Toute autre utilisation est considre comme non conforme ; la socit TURCK dcline toute responsabilit en cas de dommages causs par une utilisation non conforme. tenance de lappareil. Consignes gnrales de scurit Seul un personnel spcialement form peut monter, installer, exploiter et effectuer la main-
Une exposition prolonge dans la zone de rayonnement des ttes de lecture-criture UHF peut avoir des consquences nfastes sur la sant. Respecter les distances minimales requises par rapport la surface de rayonnement de la tte de lecture-criture. Rgion tats-Unis/
Canada Puissance de rayonnement maxi admise 4 W EIRP Distance de scurit
> 0,30 m Le rayonnement des ttes de lecture-criture UHF peut impacter certains dispositifs mdi-
caux. Respecter une distance suprieure par rapport aux sources actives de rayonnement jusqu la porte dmission maximale. Description du produit Prsentation du produit Voir fig. 1 (TN902-Q120L130-H1147) et fig. 2 (TN902-Q175L200-H1147). Fonctions et modes de fonctionnement Les ttes de lecture-criture UHF TN902- fonctionnent avec une antenne intgre dans une plage de frquence comprise entre 902 et 928 MHz. Les appareils permettent dcrire et de lire sur les supports de donnes UHF en mode Single-Tag et Multi-Tag. En outre, les appareils crent une zone de transmission dont la taille et ltendue dpendent entre autres des supports de donnes utiliss et des conditions dutilisation de lapplication. Les distances maximales de lec-
ture-criture sont indiques dans les fiches techniques. Les appareils peuvent tre largement tests, paramtrs et configurs via un PC laide doutils logiciels. Montage Les appareils peuvent tre monts dans nimporte quelle direction. Montez lappareil avec les accessoires de fixation correspondants. Choisissez au moins 20 cm comme distance minimale entre deux ttes de lecture-criture, prfrer plutt une distance de 50 cm (fig. 3). Pour les configurations de portail (fig. 4), choisissez une distance de minimum 3,5 m. Lors du montage, respectez une distance minimale de 50 cm entre la tte de lecture-criture et le sol, les fluides et les mtaux (fig. 5). Vissage sur plaque de montage Fixez lappareil comme indiqu sur la figure 6. Montage sur mt et tube Fixez lappareil comme indiqu sur la figure 7. Montage sur bras de fixation Les fixations RH-Q240L280/Q280L640 (n dident. 7030296) ne sont pas fournies. Fixez lappareil comme indiqu sur la figure 8. Raccordement DANGER Risque d'effet sur les dispositifs mdicaux lectriques comme les stimulateurs cardiaques Risque mortel en raison d'une perturbation ou d'une panne des dispositifs mdicaux Informez-vous sur la manire dont la puissance de rayonnement paramtre peut impac-
Informez-vous sur les distances respecter par rapport aux sources de rayonnement en fonction du dispositif mdical que vous portez. Respectez une distance suprieure par rapport aux sources actives de rayonnement jusqu' la porte d'mission maximale de la source de rayonnement. Raccordez lappareil via des connecteurs enfichables M12 avec linterface BL ident. TN902-QL-H1147 UHF read/write heads Other documents Besides this document the following material can be found on the Internet at www.turck.com:
Data sheet RFID engineering manual Startup manuals User manuals for the RDemo and WebConfig software tools Device approvals For your safety Intended use The devices are designed for installation in large-scale industrial plants and equipment and for use in industrial automation applications. The BL ident UHF read/write heads are used for contactless data exchange with the BL ident tags in the BL ident UHF RFID system. The possible read/write distances may vary according to factors such as component tolerances, mounting locations, ambient conditions and the effect of materials (particularly metal and liquids). For this reason, the application must be tested in all cases under real conditions (particularly with read and write operations in motion). The devices can only be operated in countries in which a frequency of 902928 MHz is permitted for the use of passive UHF-RFID. The devices must only be used as described in these instructions. Any other use is not in accor-
dance with the intended use; TURCK accepts no liability for any resulting damage. personnel. General safety notes The device must only be fitted, installed, operated and maintained by trained and qualified Any extended stay within the area of radiation of the UHF read/write heads may be harmful to health. Observe minimum distances from the actively radiating surface of the read/write head. Region USA/Canada 4 W EIRP max. permissible total radiant output power Safety distance
> 0.30m The radiation of the UHF read/write heads may impair the operation of medical equipment. Keep an additional distance from active radiation sources up to the maximum transmission distance. Product description Device overview See Fig. 1 (TN902-Q120L130-H1147) and Fig. 2 (TN902-Q175L200-H1147). Functions and operating modes The TN902- UHF read/write heads operate with an integrated antenna in a frequency range of 902928 MHz. The devices enable passive UHF tags to be read or written in single and multi-tag operation. For this the devices form a transmission zone that varies in size and range according to the tags used and the operating conditions of the application. Refer to the data sheets for the applicable maximum read/write distances. The devices can be extensively tested, configured and parameterized from a PC using the specified software tools. Mounting The devices can be mounted in any position. Mount the device with the associated fixing accessories. Select 20 cm between two read/write heads, a distance of 50 cm is recommended (Fig. 3). With portal configurations (Fig. 4) choose a distance of at least 3.5 m. Keep a minimum distance of 50 cm between a read/write head and the ground, liquids or metals (Fig. 5). Screw fastening on a mounting plate Mount the device as per Fig. 6. Mast/tube mounting Mount the device as per Fig. 7. Mounting with mounting bracket The RH-Q240L280/Q280L640 mounting bracket (Ident no. 7030296) is not supplied with the device. Mount the device as per Fig. 8. Connection DANGER Effect on electrically controlled medical devices such as pacemakers Danger to life due to malfunction or failure of medical equipment Find out the extent to which the radiation strength of your medical devices is affected. Find out the permissible distances from radiation sources for the devices you are using. Keep an additional distance from active radiation sources up to the maximum transmis-
sion distance of the radiation source. Connect the device via the M12 connector to the BL ident interface. Commissioning The device is operational automatically once the cables are connected and the power supply is switched on. Informieren Sie sich ber die fr Ihr eingesetztes Hilfsmittel zulssigen Abstnde zu ter votre dispositif mdical. Hilfsmittel beeinflusst. Strahlungsquellen. Hans Turck GmbH & Co. KG | D500049 2015-09 DE FR EN DE Kurzbetriebsanleitung FR Guide dutilisation rapide EN Quick-Start Guide Betreiben LED-Anzeigen LED 1 (grn) aus wei leuchtet dauerhaft grn leuchtet dauerhaft LED 2 (gelb) aus wei leuchtet dauerhaft aus LED 3 (rot) aus wei leuchtet dauerhaft aus grn leuchtet dauerhaft gelb leuchtet dauerhaft aus grn leuchtet dauerhaft gelb leuchtet dauerhaft rot leuchtet dauerhaft grn blinkt aus grn blinkt gelb leuchtet dauerhaft Lauflicht: grn > gelb > rot aus aus Bedeutung Betriebsspannung ausgeschaltet Startphase Betriebsspannung eingeschal-
tet, Funkfeld ausgeschaltet, kein interner Fehler Betriebsspannung eingeschal-
tet, Funkfeld eingeschaltet, kein interner Fehler Betriebsspannung eingeschaltet, Funkfeld eingeschaltet, interner Fehler Zugriff auf Datentrger erfolg-
reich Datentrger befindet sich im Funkfeld Testmodus Einstellen und Parametrieren Die Gerte lassen sich ber Software-Tools mit einem PC parametrieren. Weitere Informationen finden Sie in den BL ident-Inbetriebnahmehandbchern. Reparieren Das Gert ist nicht zur Reparatur durch den Benutzer vorgesehen. Sollte das Gert defekt sein, nehmen Sie es auer Betrieb. Bei Rcksendung an TURCK beachten Sie bitte unsere Rcknah-
mebedingungen. Entsorgen Die Gerte sind fr den Einbau in industrielle Groanlagen und Growerkzeuge bestimmt. Die Gerte mssen fachgerecht entsorgt werden und gehren nicht in den normalen Hausmll. Mise en marche Aprs avoir raccord les cbles et aprs mise sous tension, lappareil se met automatiquement en marche. Utilisation Visualisations par LED LED 1 (verte) teint blanc allum en fixe vert allum en fixe teint LED 2 (jaune) teint blanc allum en fixe LED 3 (rouge) teint blanc allum en fixe teint vert allum en fixe jaune allum en fixe teint vert allum en fixe jaune allum en fixe rouge allum en fixe vert clignotant teint vert clignotant jaune allum en fixe Chenillard: vert > jaune > rouge teint teint signification Tension de service dsactive Phase de dmarrage Tension de service active, champ radio dsactiv, absence d'erreur interne Tension de service active, champ radio activ, absence d'erreur interne Tension de service active, champ radio activ, erreur interne Accs russi au support de donnes Le support de donnes se trouve dans le champ radio Mode test Rglage et paramtrage Les appareils peuvent tre paramtrs sur un PC via les outils logiciels. Vous pourrez trouver des informations supplmentaires dans les manuels de mise en service BL ident. Rparation Lappareil nest pas conu pour tre rpar par lutilisateur. Si lappareil prsente des dfauts, mettez-le hors service. En cas de retour TURCK, veuillez respecter les conditions de reprise. Mise au rebut Les appareils sont conus pour une intgration au sein dinstallations et doutils industriels de grandes dimensions. Les appareils doivent tre mis au rebut de manire conforme et ne doivent pas tre jets avec les dchets mnagers normaux. Operation LEDs LED 1 (green) off white continuously lit green continuously lit LED 2 (yellow) off white continuously lit off LED 3 (red) off white continuously lit off green continuously lit yellow continuously lit off green continuously lit yellow continuously lit red continuously lit green flashing off green flashing yellow continuously lit Running light: green > yellow > red off off Meaning Operating voltage switched off Start phase Operating voltage switched on, radio field switched off, no internal error Operating voltage switched on, radio field switched on, no internal error Operating voltage switched on, radio field switched on, internal error Access to the data areas suc-
cessful Data carrier located in the radio field Test mode Setting and parameterization The devices can be parameterized via software tools with a PC. Further information is provided in the BL ident startup manuals. Repair The device must not be repaired by the user. The device must be decommissioned if it is faulty. Observe our return acceptance conditions when returning the device to TURCK. Disposal The devices are designed for installation in large-scale industrial installations and equipment. The devices must be disposed of correctly and must not be included in normal household garbage. TN902--H1147 FCC/IC Digital Device Limitations TN902-Q120L130-H1147 FCC ID: YQ7TN902-Q120L131 IC ID: 8821A-T902Q12L14 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)
(2) this device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1)
(2) lappareil ne doit pas produire de brouillage, et lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This equipment generates, uses, and can radiate radio frequency energy and, if This equipment complies with FCC/IC exposure limits set forth for an uncontrolled environ-
ment. This equipment should be installed and operated with minimum distance 30 cm between the radiator & your body. CAN ICES-3 (A)/NMB-3(A) Use only with listed LPS or class 2 power supply!
FCC/IC Digital Device Limitations TN902-Q175L200-H1147 FCC ID: YQ7TN902-Q175L201 IC:
8821A-T902Q17L21 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)
(2) this device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is sub-
ject to the following two conditions:
(1)
(2) this device may not cause interference, and this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1)
(2) lappareil ne doit pas produire de brouillage, et lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Note: This equipment has been tested and found to comply with the limits for a Class A These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. digital device, pursuant to part 15 of the FCC Rules. This equipment complies with FCC/IC exposure limits set forth for an uncontrolled environ-
ment. This equipment should be installed and operated with minimum distance 30 cm between the radiator & your body. CAN ICES-3 (A)/NMB-3(A) Use only with listed LPS or class 2 power supply!
Power-on indication Diagnostic display TN902-Q175 non-flush
-25+50 C 1224 VDC TN902-Q120 non-flush
-25+50 C 1224 VDC alternating electromagnetic field alternating electromagnetic field 902928 MHz ISO 18000-6C EPCglobal Gen 2 200 kHz 0.5 W (ERP), adjustable RHCP 110 Technical Data | Technische Daten | Donnes techniques Technical features Mounting conditions Ambient temperature Operating voltage Data transfer Operating frequency Radio communication and protocol standards Channel spacing Output power Antenna polarization Antenna HBPW Read/write distance max. 1500 mm Output function Construction Dimensions Housing material Material active area Connection Vibration resistance Shock resistance IP rating MTTF 902928 MHz ISO 18000-6C EPCglobal Gen 2 200 kHz 1 W (ERP), adjustable RHCP 90 4000 mm 4-wire, read/write rectangular 200 175 60 mm Aluminium, AL, silver plastic, ABS, black male, M12 1 55 Hz (1 mm) 30 g (11 ms) IP67 51 years acc. to SN 29500 (Ed.99) 40 C LED green/yellow/red different settings 4-wire, read/write rectangular 130 120 60 mm Aluminium, AL, silver plastic, ABS, black male, M12 1 55 Hz (1 mm) 30 g (11 ms) IP67 51 years acc. to SN 29500 (Ed.99) 40 C LED green/yellow/red differently adjustable Hans Turck GmbH & Co. KG | 45472 Muelheim an der Ruhr | Germany | Witzlebenstrae 7 | Tel. +49 208 4952-0 | Fax +49 208 4952-264 | more@turck.com | www.turck.com Hans Turck GmbH & Co. KG | D500049 2015-09 DE FR EN