all | frequencies |
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|
manual | photos |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User manual | Users Manual | 319.20 KiB | October 10 2019 | |||
1 |
|
Internal Photos | Internal Photos | 1.15 MiB | October 10 2019 | |||
1 |
|
External Photos | External Photos | 1.72 MiB | October 10 2019 | |||
1 | Block Diagram | Block Diagram | October 10 2019 | confidential | ||||
1 | Cover Letter(s) | October 10 2019 | ||||||
1 | ID Label/Location Info | October 10 2019 | ||||||
1 | Cover Letter(s) | October 10 2019 | ||||||
1 | Operational Description | Operational Description | October 10 2019 | confidential | ||||
1 | RFID Description | Operational Description | October 10 2019 | confidential | ||||
1 | Schematics 2 | Schematics | October 10 2019 | confidential | ||||
1 | Schematics 1 | Schematics | October 10 2019 | confidential | ||||
1 | Schematics 3 | Schematics | October 10 2019 | confidential | ||||
1 | Schematics 4 | Schematics | October 10 2019 | confidential | ||||
1 | Test Setup Photos | October 10 2019 | ||||||
1 | Test Report | October 10 2019 |
1 | User manual | Users Manual | 319.20 KiB | October 10 2019 |
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Electric Water Cooler and Bottle Filling Stations MODELS 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF No. 0510000866 (1A.2) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. CAUTION: Disconnect electrical power to outlet before installing or servicing. SAFETY PRECAUTIONS NOTICE:
A. The electrical receptacle must have code-approved ground-fault circuit interrupter (GFCI) protection for personnel. B. Care should be taken not to damage refrigeration system lines or electrical wires during installation. C. Installation must conform to all applicable codes and standards. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL:
TECHNICAL SUPPORT:
1-800-766-5612 FOR CUSTOMER SERVICE:
1-888-640-4297 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 1 of 11 REQUIRED TOOLS (OR EQUIVALENT):
Adjustable Wrench
1/4 Bit-holding screwdriver (7-3/4 max length),
1/4 Bit-holding screwdriver (4 max length, required for installs at Child ADA height only)
#2 Phillips bit
Flat-blade bit
T15, T20, T25 Torx bits (supplied when required)
5/16 Nut driver bit (not necessary but will make some steps easier).
Trimming tool for ABS pipe (necessary for some retrofits)
Small bubble level
Tape measure and tools for properly marking and measuring wall
Clean cloth or paper towels
Tubing cutter for polyethylene Tubing
Small diagonal cutting pliers (required for high/low units only) REQUIRED PARTS (NOT SUPPLIED):
P-trap (1-1/4 recommended) with appropriate seal for 1-1/4 OD tailpiece
Suitable trap adapter (if not already installed see installation drawing for details)
Suitable angle stop valve with 3/8 compression outlet (if not already installed see installation drawing for details)
1/4 fasteners suitable for fastening water cooler to structural material in wall.
Plastic cup (for bleeding air out of system following install) LOCATION OF UNIT: The Model 12XX Series Electric Water Coolers and Bottle Filling Stations are suitable for indoor use only. These units are not suitable for corrosive environments (such as enclosed chlorinated pool areas) or particularly dusty areas. The ambient air temperature must be maintained between 40F and 104F at all times. Installation into a location not meeting these limitations will void the warranty. SUPPLY LINE: The minimum recommended line size is 1/2IPS with 30-90 psig (2-6 ATM) flowing pressure. Where sediment or mineral content is a problem, an upstream water pre-
filter is recommended. PLUMBING CONNECTIONS: Inlet is 3/8 OD polyethylene tubing. A suitable plastic ferrule and metal insert are provided to allow direct connection to a 3/8 compression water stop valve. Tailpiece is 1-1/4 OD ABS. INSTALLATION PROCEDURE GENERAL NOTES:
Certain installation sections below may not apply to your specific model. Skip to the next heading in such cases. For all plastic push-in type fitting connections, only connect NSF-61 soft-copper or plastic tubing. The following assembly instructions must be followed to ensure a watertight connection:
a. If tubing needs to be shortened, cut tubing square and clean. b. Mark from end of tube the depth of insertion (See table below). c. Push tube into the fitting until it bottoms out. d. To remove, depress collet and pull tubing out. Tube OD Size OD Tolerance Insertion Depth 1/4 3/8
.004
.004 11/16 3/4 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 2 of 11 A. INSTALLATION OF ELECTRIC WATER COOLER drawing. 1. Verify that the electrical receptacle, water supply/valve, and drain locations are all in accordance with the installation a. NOTE: The installation drawing addresses new installations as well as retrofits over existing water coolers. Consult the retrofit pages of the installation drawing if uncertain whether a retrofit will be possible in your case. 2. Remove the hanger bracket from the back of the cooler by removing (1) screw. 3. Mount the hanger bracket on the wall using (4) 1/4 structural screws. a. NOTE: The screws must engage into structural material such as concrete, metal backing, wood blocking, etc. DO NOT use drywall anchors. b. NOTE: The hanger bracket has a notch indicating the centerline of the water cooler, as well as a second notch off-center indicating the ideal drain line location at the wall. If the centerline of the drain does not align with the second notch, consider moving the bracket location to accommodate. c. NOTE: It may be convenient to mount the bottle filler and high cooler brackets at this time. Refer to the applicable steps in those sections. 4. With the cooler laying on its back, remove the (4) screws holding the skirt to the bottom of the frame. Then remove the skirt by sliding the skirt away from the cooler. If installing a high-low unit, connect the 16 water supply extension tube (with insulation) to the tee connection in the refrigerated unit. The water tube should pass through the hole in the upper left side of the frame. 5. 6. Hang the cooler onto the hanger bracket. a. NOTE: The hanger bracket must go through the holes in the cooler frame that are shaped like a sideways letter P. b. NOTE: The bracket allows for some lateral adjustment of the cooler location. Slide the cooler laterally as needed at this time. 7. Secure both the lower right and lower left ends of the cooler to the wall using at least (2) 1/4 or 3/8 structural screws. These screws should go through the holes which are approximately 5 from the bottom of the cooler. Washers may be required. a. NOTE: The screws must engage into structural material such as concrete, metal backing, wood blocking, etc. DO NOT use drywall anchors. 8. Connect the water inlet line (attached to either the strainer or filter, as applicable), to the water stop by following the steps below. a. Cut the inlet line square and clean to the appropriate length, if needed. b. Install the compression nut (included with your supply valve), followed by the plastic ferrule (supplied), and the brass tube support (supplied) onto the inlet line. Note the correct orientation of the plastic ferrule, as shown in Figure 2. Do not use the brass ferrule included with your supply valve. Insert the inlet line into the supply valve until it bottoms out. Thread the nut down onto the supply valve until finger tight. Tighten exactly 1.25 additional turns with a wrench. c. 9. 10. Install the P-trap. If necessary, trim the water coolers drain tailpiece in place so it interfaces properly with the P-trap inlet. Pliers may be required to tighten the nuts to a leak-tight condition. If the unit has a filter, install the filter now. Take care not to damage the circuit board which is near the filter head. 11. Note that the thermostat is factory set at 50F (5F) under normal conditions. The minimum thermostat set point varies with altitude. Adjust 1/16th turn counterclockwise
(warmer) from cold position for every 1500 ft above sea level to prevent freezing of water. If installing a bottle filler unit or high/low unit, proceed to those steps. If not, proceed to START-UP section. 12. Figure 1: Cooler Bracket Location Figure 2: Supply Valve Connection B. INSTALLATION OF BOTTLE FILLER 13. Mount the bottle filler wall bracket on the wall using (4) 1/4 structural screws and the (4) supplied washers. See installation drawing for dimensional details. a. NOTE: The screws must engage into structural material such as concrete, metal backing, wood blocking, etc. DO NOT use drywall anchors. b. NOTE: The hanger bracket has a notch indicating the centerline of the bottle filler, which should align with the centerline of the water cooler. 14. Check that the bottle filler wiring harness extends through the upper rear of the water cooler. If it does not, pull it out through the upper rear of the water cooler. 15. Begin to feed the bottle filler water tubing through the slot in the back of the water cooler. With the lower brackets partially engaged into the slots, connect the wiring harness to the circuit board on the back of the bottle filler. 16. Fully install the bottle filler by sliding it down fully onto its wall bracket. Route the water tubing out the left side of the water cooler. The bottle filler should rest completely against the top of the water cooler, with no gap. It should also be flush with the wall surface. 17. Slide the supplied foam insulation tubing over the end of the bottle filler water tubing, which is now running down through the water cooler. 19. 18. Connect the bottle filler water tubing to the 1/4 push-in elbow connector located inside of the water cooler. Tuck this tubing into the water cooler so that it does not protrude or kink. Install the (2) supplied #10-24 T25 drive machine screws through the sides of the water cooler frame and into the lower brackets. Tightening these screws will lock the bottle filler into position, so be sure that the bottle filler is fitting tightly against the top of the water cooler. 20. Remove the protective plastic film from the sensor area of the bottle filler. 21. If installing a high/low unit, proceed to those steps. If not, proceed to START-UP section. Figure 3: Bottle Filler Lower Brackets 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 3 of 11 C. INSTALLATION OF HIGH-SIDE (LEFT) WATER COOLER 22. Remove the hanger bracket from the back of the cooler by removing (1) screw. 23. With the cooler laying on its back, remove the (4) screws holding the skirt to the bottom of the frame. Then remove the skirt by sliding the skirt away from the cooler. 24. Mount the hanger bracket on the wall using (4) 1/4 structural screws, in accordance with the installation drawing. a. NOTE: The screws must engage into structural material such as concrete, metal backing, wood blocking, etc. DO NOT use drywall anchors. b. NOTE: The hanger bracket has a notch indicating the centerline of the water cooler. 25. Using cutting pliers, cut the cable-tie holding the unconnected wires in the upper left side of the refrigerated cooler. These wires will supply power, signal, and ground to the high side water cooler. Take care not to damage the wires when cutting the tie. 26. Remove the protective plastic wrap from the feedthrough cover. 27. Feed the water tubing and wiring through the feedthrough cover. Install the feedthrough cover by sliding its upper right tab behind the edge of the black cap of the right side water cooler (see installation drawing). Use a bubble level to ensure the left edge of the feedthrough cover is vertical. Secure with a 1/4 or #10 screw. a. NOTE: Installing the screw into structural material is recommended. Toggle bolts or drywall anchors can be used but they may make the unit more susceptible to damage from vandals. 28. Hang the cooler onto the hanger bracket. a. NOTE: The bracket must go through the holes in the cooler frame that are shaped like a sideways letter P. b. NOTE: The bracket allows for some lateral adjustment of the cooler location. Slide the cooler laterally until it touches the side of the feedthrough cover. 29. Secure both the lower right and lower left ends of the cooler to the wall using at least (2) 1/4 or 3/8 structural screws. These screws should go through the holes which are approximately 5 from the bottom of the cooler. Washers may be required. a. NOTE: The screws must engage into structural material such as concrete, metal backing, wood blocking, etc. DO NOT use drywall anchors. 30. Route the drain hose from the left unit to the right unit. Attach to the open branch of the drain tailpiece using the supplied hose clamp, ensuring that the drain hose slopes downward over its entire length. 31. Attach the 3/8 water supply line to the 3/8 connector in the left side unit. 32. Connect the wire connector in the left unit. 33. Remove the green ground screw from its hole in the left unit and use it to secure the green ground wire to that same location. D. START-UP plastic from the skirt(s). 34. Open the water supply valve and check the system for leaks. 35. Plug the power cord into the wall receptacle (which should presently be powered off at the breaker panel). Check that all wiring is fully contained within the unit and that no wires are impeding fan blade movement. 36. Peel back the protective plastic from the back flanges and top 1 of the skirt(s). 37. Taking care not to scratch the black plastic parts behind the bowl, reinstall the skirt(s). Finish removing the protective 38. Reconnect power at the breaker panel, then place a cup over the bubbler (to minimize splattering) and push the front button to activate the bubbler flow. Keep the button depressed until all air is purged out of the water line. a. NOTE: If the unit has a filter, run the bubbler for 10 minutes in order to properly flush the filter. 39. 40. If a bottle filler has been installed, place a cup under the nozzle of the bottle filler and run the water until the air has been purged out of the water line. If a high/low unit has been installed, place a cup over the bubbler of the second unit and push the front button to activate the bubbler flow. Keep the button depressed until the air has been purged out of the water line. 41. The stainless steel panels can be cleaned with the provided cleaning wipe. Buff off excess with a clean cloth or paper towel. Do not allow the cleaning fluid to touch the plastic parts or the bottle filler. 42. After allowing a few minutes for the water to cool down, enjoy a cold drink of water. E. OPTIONAL PROGRAMMING INSTRUCTIONS (BOTTLE FILLER UNITS ONLY) To enter programming mode, remove the clear cover underneath the bowl, and hold the button until the up/down arrow keys and select appear on the bottle filler display. Programming mode enters at the top-level menu. In general, the up/down arrows and select keys work as follows;
Up/Down Arrows Cycle through the top-level menu items or values in the programmable fields Select enters programming of the associated top-level menu item, or sets value and advances to next programmable field, or programs value
(indicated by value flashing) prior to returns to the main menu Programming the Haws 12xx Electronic Water Cooler through the Bottle Filler user interface is intuitive. However, the following Electronic Water Cooler and Bottle Filler Programming Table can be used as a guide while programming the unit, which are retained during power outages. Replace the clear plastic cover after programming the unit. Figure 4: Programming Mode Button viewed from underside of bowl 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 4 of 11 Top-Level Menu Backlight Sensor Errors Electronic Water Cooler and Bottle Filler Programming Table Arrows (cycle through) 100%, 75%, 50%, 25%, Cancel Select Percentage Value - programs brightness Cancel returns to main menu Range (rng) from 1 to 10, Cancel Range 1 to 10 - programs range Cancel returns to main menu None or Cancel returns to main menu No Errors None or Cancel. Errors - error codes (see Error Code Table for details), Clear, and Cancel Set Day Days of week or Cancel Time Hour from 1 to 12, or Cancel Minute from 00 to 59, or Cancel A, P, or Cancel Energy* M-F, Sa-Su, and Cancel On 1 to 12, OFF, or Cancel A, P, or Cancel Off 1 to 12, or Cancel A, P, or Cancel Review Error Code shows human readable (see next Arrow) Clear clears error codes Cancel returns to main menu Day of week programs day Cancel returns to main menu 1 to 12 programs hour of day 00 to 59 programs minute of hour A or P programs 12-hour clock AM or PM Cancel returns to main menu M-F or Sa-Su - enters programmable energy saving for that portion of the week and advanced to hour to turn ON energy saving mode Cancel returns to main menu On 1 to 12 sets hour to turn ON energy saving and advance to A or P field (see Note 1) Off turns OFF energy saving for that portion of the week (i.e. Mon-Fri or Sa-Su) and returns to main menu Cancel returns to main menu without changing program. Sets 12-hour clock AM or PM and advanced to programming OFF time (see Note 1) Cancel returns to main menu with changing program. Off 1 to 12 sets hour to turn Off energy saving and advance to A or P field (see Note 1) Cancel returns to main menu without changing program Sets 12-hour clock AM or PM and advanced to OFF setting (see Note 1) Cancel returns to main menu without changing program. Default 100%
Rng 4 None Sunday 12:00A Mon-Fri
= OFF Sa-Su
= OFF N/A Cycles through time, day, energy program, backlight setting, sensor setting, filter usage, and errors codes. Cancel returns to main menu without factor reset Yes resets to facture defaults, but saves bottle count Reset Cancel or Yes See defaults above Abort N/A Notes: * Programmable energy savings overrides Smart Energy Save, but still allows the system to enter Smart Exits programming mode Energy Saving when outside the programmed energy saving times (see section G.1 Smart Energy Saving) 1. Example: To turn on programmable energy saving from 6p.m. to 5a.m., Monday through Friday, use the up/down arrows and follow the flashing field prompt to select on 6 the P, then oFF 5 and A. 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 5 of 11 F. MAINTENANCE F.1. CLEANING
Metal parts can be cleaned with either of the following:
o A clean towel, dampened by warm water with or without a mild hand dishwashing detergent. o Stainless steel cleaning wipes. Buff off excess with a clean cloth or paper towel. Do not allow the cleaning fluid to touch the plastic parts or the bottle filler. Plastic parts (including bottle filler):
o A clean towel, dampened by warm water with or without a mild hand dishwashing detergent. Condenser: If dust builds up on the condenser, it can negatively impact the water cooler performance. Clean the condenser using a shop vacuum or an air blower gun. Take care not to damage the fins during the cleaning process.
F.2. Y-STRAINER CLEANOUT (MODELS WITHOUT A FILTER) 1. Remove the (4) screws holding the skirt to the bottom of the frame. Then remove the skirt by sliding the skirt away from the cooler. a. NOTE: For dual units, the y-strainer is in the right-side unit. 2. Turn the supply valve to the off position 3. Remove the cap from the strainer using two adjustable or open-ended wrenches. a. NOTE: Some water will likely drip out of the y-strainer as you open it. 4. Clean the strainer screen using clean water. 5. Re-assemble the cap to the strainer. 6. Turn the supply valve to the on position and check for leaks 7. Taking care not to scratch the black plastic parts behind the bowl, reinstall the skirt. F.3. FILTER REPLACEMENT (MODELS WITH A FILTER) Caution: Take care not to damage the circuit board located near the filter head during the following steps. Figure 5: Strainer cleanout down. 1. Remove the (4) screws holding the skirt to the bottom of the frame. Then remove the skirt by sliding the skirt away from the cooler. a. NOTE: For dual units, the filter is in the right-side unit. 2. Place a towel or bucket below the cooler to collect the small amount of water that may drip from the filter head or filter during the next steps. 3. Optional: Turn the water supply valve to the off position, and bleed pressure from the unit by operating the bottle filler or bubbler. This will improve the ease of replacing the filter. 4. Remove the old filter by turning about turn clockwise (as viewed from above) and pulling a. NOTE: There is no need to shut off the supply valve, as the filter head has a built-in valve. If you are planning to leave the unit without a filter cartridge for a protracted period of time, shut off the supply valve. 5. Install the new filter by pushing up and turning counterclockwise (as viewed from above). Note the label orientation in Figure 5. 6. Taking care not to scratch the black plastic parts behind the bowl, reinstall the skirt. 7. Using a cup to block the water flow, bleed air out of the bubbler(s) and bottle filler nozzle (if applicable) by activating the water flow until the air is purged out. 8. Run one of the bubblers for 10 minutes to properly flush the filter. Figure 6: Filter Replacement F.4. FUSE REPLACEMENT (MODELS WITH FILTER AND/OR BOTTLE FILLER) 1. Turn off power to unit 2. Remove the (4) screws holding the lower bowl support cover. a. NOTE: For dual units, the fuse is in the right-side unit. 3. Remove blown fuse and replace with a 5mm x 20mm, 10A, Fast Blow, 250VAC rated fuse. a. NOTE: Haws PN: 0210000754 4. Replace lower bowl support cover with (4) screws and turn on power to the unit 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 6 of 11 Figure 7: Fuse Replacement view from underside of bowl G. GENERAL OPERATION G.1. USING THE BUBBLER
Press the push-button on the front of the water cooler to activate the bubbler flow. G.2. USING THE BOTTLE FILLER
Remove the bottle from below the nozzle to stop the water flow. Insert a bottle below the nozzle to activate the water flow. G.3. FILTER LIFE (Filtered units only)
The filter is designed to last for a maximum of 1 year or 3,000 gallons, whichever comes first.
In order to ensure dispensed water quality, the unit will automatically disable water flow when the filter reaches expiration. Water flow will be re-enabled after the filter is replaced. G.4. SMART ENERGY SAVING (Filtered and/or Bottle Filler units)
The filtered and/or bottle filler units are set to Smart Energy Saving as the factory default. These units will automatically save energy when there in dark conditions and there has been no use.
H. NOTIFICATIONS H.1. WATER COOLER INDICATION LIGHTS (MODELS 1201SF, 1202SF, 1211SF, 1212SF)
Power = Red LED
Intermittent Flash Filter life 10% to 0% remaining Filter = Blue LED (Filtered units only) o Solid ON when power is applied o Solid ON Filter life 100% to 11% remaining o o Rapid Flash Filter life expired o OFF = Energy Saving Mode disabled o Solid ON = Energy Saving Mode enabled o
Energy Saving = Green LED Intermittent Flash Unit actively saving energy (compressor and fan disabled) H.2. BOTTLE FILLER INDICATION (MODELS WITH BOTTLE FILLER ONLY)
Bottles Saved: Indicates approximately 1 bottle saved for each 17oz dispensed from the water cooler, whether it be from a bubbler or the bottle filler. Filtering Icon (Filtered units only):
Energy Efficiency Icon o Solid ON at all times - 100%-11% filter capacity remaining o Pulsing when not activated - 10%-1% filter capacity remaining o OFF - 0% filter capacity remaining (filter expired) o Solid ON = Basic or Programmable Energy Saving Mode enabled o o OFF = Energy Saving Mode disabled Intermittent Flash = Unit actively saving energy (compressor and fan disabled) 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 7 of 11 I. TROUBLESHOOTING TROUBLESHOOTING Note: If the suggested items in the checklist fail to solve the problem, contact Haws Technical Support at 1-800-766-5612. PROBLEM No water flow from bubbler 1. a. b. c. d. a. b. c. d. e. a. b. c. d. e. a. b. c. d. e. a. a. b. a. b. a. b. a. b. REPAIR CHECKLIST Check if filter has expired. Verify supply valve is open and there is water pressure to the cooler. Verify power to the cooler. Check and replace fuse (Models 1211S, 1212S, 1201SF, 1202SF, 1211SF, 1212SF) Press front button and listen for a click or a hum to indicate whether the solenoid valve is working. Check if filter has expired. Verify supply valve is open and there is water pressure to the cooler. Verify power to the cooler. Check and replace fuse (Models 1211S, 1212S, 1201SF, 1202SF, 1211SF, 1212SF) Clean the bottle filler sensor lens with mild detergent and water. Activate sensor and listen for a click or a hum to indicate whether the solenoid valve is working. Replace filter. Verify minimum 30 psig supply pressure. Verify supply valve is in full open position. Unscrew nozzle and flush with clean water. Replace nozzle. Replace filter. Verify minimum 30 psig supply pressure. Verify supply valve is in full open position. Unscrew aerator and flush with clean water. Replace aerator. Shut off water supply and contact Haws Technical Support @ 1-800-766-5612. Unscrew bubbler nozzle and flush with clean water. Replace bubbler nozzle. Unscrew aerator and flush with clean water. Replace aerator. Check thermostat position Verify that the compressor is running (The shell should be warm to the touch after running) Unit self-purges every 24 hours if not used. Clean the bottle filler sensor lens with mild detergent and water. 2. No water flow from bottle filler 3. Low water flow from bubbler 4. Low water flow from bottle filler 5. 6. 7. 8. 9. Water leaking Water from bubbler excessively splatters when contacting bowl Water from bottle filler nozzle excessively splatters when contacting drain basin Water is not cold Bottle filler flows water by itself 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 8 of 11 OPTIONAL BOTTLE FILLER ERROR CODE TABLE TROUBLESHOOTING Note: If the suggested items in the checklist fail to solve the problem, contact Haws Technical Support at 1-800-766-5612. ERROR CODE E009 COMPCY Compressor is cycling too frequently 1. 2. 3. E012 SENOB Bottle filler sensor is obstructed E014 RFID RFID board lost communication REPAIR CHECKLIST Clear error in programming mode and power cycle unit and check error to validate. Power cycle unit and ensure fan runs initially for approximately 10 seconds. Clean condenser fins of dust and debris. Verify inlet water and ambient temperatures are below specification maximum. Clear error in programming mode and power cycle unit and check error to validate. Remove obstruction from aperture Clean aperture with soft cloth that wont scratch aperture. Check aperture for excessive scratches Clear error in programming mode and power cycle unit and check error to validate. Check cable connection to RFID board. a. b. c. d. a. b. c. a. b. 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 9 of 11 J. FEDERAL COMMUNICATIONS COMMISIONS (FCC) and INDUSTRY CANADA
(IC) COMPLIANCE STATEMENTS J.1. FCC Compliance Statement J.1.1. Part 15.19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. J.1.2. Part 15.21 Any changes or modifications to this equipment not expressly approved by Haws Corporation may cause harmful interference and void the users authority to operate this equipment. J.1.3. FCC ID FCC ID: 2AUAN-1200SF J.2. Formal notices required by the Industry Canada (IC) J.2.1. Compliance Statement This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation. J.2.2. Declaration de Conformit Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes: (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. J.2.3. IC ID IC ID: 25359-1200SF 2019 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 1455 Kleppe Lane, Sparks, Nevada 89431 800.766.5612 www.hawsco.com 08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 10 of 11 WATER COOLER WARRANTY AND LICENSE EXCEPT AS EXPRESSLY STATED HEREIN, MANUFACTURER HEREBY DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY MAY NOT BE MODIFIED OR EXTENDED WITHOUT THE WRITTEN CONSENT OF HAWS. REMEDIES AND REPLACEMENTS STATED HEREIN ARE EXCLUSIVE. IN NO EVENT SHALL HAWS BE LIABLE FOR ANY SPECIAL, PUNITIVE, CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANY PERSON INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOSS OF USE OR PROFITS, SUBSTITUTE PRODUCTS OR COSTS, PROPERTY DAMAGE, OR OTHER MONETARY LOSS. 1. TIME BASED WARRANTY FOR AUTHORIZED RESELLERS AND INITIAL PURCHASERS. Haws Corporation (Haws) warrants that every cooler and bottle filling station will be free from material defects in materials and workmanship under normal use for one (1) year from the date of installation or if earlier, eighteen (18) months from date of shipment from Haws factory. Haws warrants that the compressor and hermetically sealed refrigeration system, which includes cooling coils and tank assembly, insofar as either is part of the hermetically sealed refrigeration system, will be free from material defects in materials and workmanship under normal use for an additional four (4) years from the end of the initial time period described in the first sentence of this paragraph. (This warranty for years 2 through 5 is pro-rated for the remaining replacement value based on the portion of the warranty period expired). The warranties set forth in this paragraph are collectively referred to herein as the Limited Warranty. This Limited Warranty applies only to coolers and bottle filling stations purchased by (i) authorized resellers of Haws products, and (ii) the initial purchaser (first owner) who purchases the product other than for resale. 2. WARRANTY VOID. The products must be installed and operated in accordance with Hawss written instructions included with each unit, or the Limited Warranty will be null and void. The products are designed to operate on 30 - 90 psi flowing inlet pressure. Depending on water temperature and flowing inlet pressure for bi-level water coolers, ADA-compliant bubbler stream heights are not guaranteed when both bubblers are activated simultaneously. Where products are found by Haws to have been subjected to negligence, recklessness, accident, alteration, abuse, carelessness, misuse, misapplications, corrosive type atmospheres, unsuitable environments, faulty installation, or abnormal use, this Limited Warranty will be null and void. RESPONSIBILITIES. The owner is responsible for any repairs or maintenance not covered by this Limited Warranty, including service for issues that not 3. warrantied hereunder. The owner must deliver written notice to Haws of any imperfections at the time of installation without delay. Haws obligations under this Limited Warranty are limited to labor and parts to repair or replace any part which is expressly covered by this Limited Warranty at its factory repair department, when the product is in the United States or Canada. The Limited Warranty applicable to any replacement unit shall not extend beyond the warranty period of the original unit
(e.g., if a replacement cooler is installed 8 months after installation of the original cooler, the replacement cooler will be warrantied for 4 months from installation.). Haws duty also includes costs of outbound freight (but not express freight) of the part or parts from the factory repair department, but only if the part or parts, and the purported defect or defects, are covered by this Limited Warranty, in Haws sole discretion. When the product is located outside the United States and Canada, Haws obligation under this Limited Warranty includes only providing a replacement for any part expressly covered by this Limited Warranty which is found to be defective by Haws or its agent but does not include any obligation to provide labor or to pay labor costs incurred in connection with the replacement. Haws duties also include cost of outbound freight (but not express freight) of the part or parts from the factory repair department to (but not beyond) the port in the United States from which the part or parts are shipped to the final destination, but only if the part or parts, and the purported defect or defects, are covered by this Limited Warranty, in Haws sole discretion. To obtain warranty service, Owner must call the factory. For the nearest Manufacturer factory, call (800) 766-5612. 4. EXCLUSIONS. This Limited Warranty does not include the costs of any labor for normal maintenance including adjustments such as water stream quality, water temperature or energy savings mode. The water system and laminar flow inserts are not covered by this Limited Warranty if Haws determines that they have become inoperative due to liming, sand or similar residue or decomposition. This Limited Warranty is voided if repairs are made by any unauthorized party or the serial number data plate is removed or has been modified from its original state. Normal deterioration of finish caused by ordinary wear and tear, corrosion, or exposure is not covered by this Limited Warranty. Haws is not responsible for any repairs whatsoever to walls on which the coolers and bottle filling stations are installed. If inlet pressure is above 90 psi, a pressure regulator must be installed in the supply line to preserve this Limited Warranty. Any damage caused by connecting the water cooler and bottle filling stations to supply line pressures lower than 30 psi or higher than 90 psi is not covered by this Limited Warranty. If the coolers or water filling stations, as applicable, are altered, modified, or combined with any other machine or devise this Limited Warranty is null and void. Caution: alteration or modification of the coolers and/or water filling stations may cause serious flooding and/or hazardous electrical shock or fire. 5. LICENSE. If the water cooler or bottle filling station includes embedded software, the owner and those using the product are granted a limited, restricted, non-exclusive, non-transferable, non-sublicensable license to use such embedded software solely for the operation of the product in owners business and not for any commercial purpose. Haws retains title to the embedded software and all intellectual property rights therein and in any derivatives thereof. The owner and those using the product shall not remove or alter notices, legends or trademarks contained in the embedded software, nor shall they translate, reverse engineer, decompile or disassemble the embedded software except to the extent applicable law specifically prohibits this restriction. Any use of such embedded software not contemplated herein will void this Limited Warranty. The embedded software is provided as is and no warranty is provided by Haws. Haws will provide further information concerning this license upon request sent to the address set forth herein. Product Details:
Cooler Model Number:
Serial Number:
Date of Installation:
Location:
Building:
State:
Installed By:
08/2019 Models 1201S / 1201SF / 1211S / 1211SF / 1202S / 1202SF / 1212S / 1212SF Page 11 of 11
1 | Internal Photos | Internal Photos | 1.15 MiB | October 10 2019 |
Figure 1 - EWC Board Front (0210000743) Figure 2 - EWC Board Back (0210000743) Figure 3 - BF Board Front (0210000744) Figure 4 - BF Board Back (0210000744) Figure 5 - RFID Board Front (0210000745) Figure 6 - RFID Board Back (0210000745) Figure 7 - Nozzle LED Board (passive LEDs) Front and Back (0210000746) Figure 8 - BF Display (passive LEDs) Front (0210000951) Figure 9 - BF Display Board (passive LEDs) Back (0210000951) Figure 10 RFID Tag Front and Back (0210000822) IDENTIV 25mm Wet Inlay (NXP SLIX)
1 | External Photos | External Photos | 1.72 MiB | October 10 2019 |
Figure 1- 1212SF Front Exterior Figure 2 - 1212SF Right Exterior Figure 3 - 1212SF Left Exterior Figure 4 - 1212SF Back Exterior Figure 5 - 1212SF Top Exterior Figure 6 1212SF Bottom Exterior Figure 7 - 1202SF Front Exterior Figure 8 - 1202SF Right Exterior Figure 9 - 1202SF Left Exterior Figure 10 - 1202SF Back Exterior Figure 11 - 1202SF Top Exterior Figure 12 - 1202SF Bottom Exterior
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-10-10 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-10-10
|
||||
1 | Applicant's complete, legal business name |
Haws Corporation
|
||||
1 | FCC Registration Number (FRN) |
0028725133
|
||||
1 | Physical Address |
1455 Kleppe Lane
|
||||
1 |
Sparks, NV
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@intertek.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AUAN
|
||||
1 | Equipment Product Code |
1200SF
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
S**** T**** H********
|
||||
1 | Title |
Compliance Manager
|
||||
1 | Telephone Number |
77535********
|
||||
1 | Fax Number |
77535********
|
||||
1 |
s******@hawsco.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
HAWS Corporation
|
||||
1 | Name |
S**** T****** H********
|
||||
1 | Physical Address |
1455 Kleppe Ln
|
||||
1 |
Sparks, 89431
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
77535********
|
||||
1 | Fax Number |
77535********
|
||||
1 |
s******@hawsco.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Haws Electric Water Cooler | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
IntertekTesting Services NA Inc.
|
||||
1 | Name |
C******** P******
|
||||
1 | Telephone Number |
650-4********
|
||||
1 | Fax Number |
650 4********
|
||||
1 |
c******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC