Installation and Operation Manual Wireless Space Sensor Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be etermined, by turning this equipment OFF and ON, the user may correct the interference by: (1) Reorienting or relocating the receiving antenna, (2) Increasing separation between the equipment and wireless components, (3) Connecting the equipment to a different outlet circuit from that of the wireless components, or (4)Consulting an experienced radio/TV technician for assistance. The antenna supplied by Heat-Timer Corporation must be used (gain <= 6dB). It is recommended not to operate the device (transceiver) with persons closer than 20cm to the antenna. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. 059049-00 Rev. 2WirelessSNRInstallationandOperationManual Contents Controls,Indicators,andConnections.....................3 Specifications.........................................4 InstallationInstructions ................................5 RequiredMaterials(NotSupplied).....................5 ProgrammingtheSystemID ..........................5 MountingtheWirelessSNR...........................7 PerformingtheICMSConfiguration....................7 DetailedOperation ....................................8 ControlTheory .....................................8 Troubleshooting .......................................8 WirelessSystemInformation ............................9 Notes ...............................................10 059049-00 Rev. HeatTimerCorp. Controls,Indicators,andConnections3 Controls,Indicators,andConnections Figure1: WirelessSpaceSensorControls,Indicators,andConnections 1 2 3 6 4 5 Description Description Item 1 2 ModeButton InternalAntenna UsetosettheWirelessSNRmode(Normal,Install,or OnePacket). StatusIndicators(LEDs) Batteries Item 4 5 ProvidepowerfortheWirelessSNR(2)AA1.5Valkaline batteries. RedmainLEDblinkswheninInstallmode. GreenmainLEDblinkswhendatareceptionbya destinationdevicehasbeenacknowledged. RedRFLED(nearesttheRFModule)blinkswhen transmittingdatainInstallmodeorifOnePacket modehasbeeninitiated. IfallthreeLEDsareblinking,noSystemIDhasbeen configured. 3 RFModule 6 RS485Connector Transmit/receiveradiosignalsto/fromotherdevices. ProgramminginterfacefortheWirelessProgrammeror MSIHub. HeatTimerCorp. 059049-00 Rev. 4WirelessSNRInstallationandOperationManual Specifications Dimensions(WxHxD):.................................................. 5x25/8x7/8(127mmx66.68mmx22.23mm) MountingLocations:.....................................................................................WallMount TemperatureRange: ...................................................................... 40Fto150F(4.5Cto66C) PowerInput: ............................................................................AAAlkaline(1.5V)Batteries(2) Transmission/Reception: ............................................................................ InternalAntenna Frequency: ........................................................................................ RF900MHzFHSS SignalStrength: ................................................................................... 25mWto100mW ProgrammingInterface: ...................................................................................... RS485 UserInterface: ..........................................................StatusIndicators(2MainLEDs,1RFModuleLED) ModeButton(1) 059049-00 Rev. HeatTimerCorp. InstallationInstructions5 InstallationInstructions TheWirelessSNRinstallationprocessconsistsofthefollowingbasicsteps:
1. ProgrammingtheWirelessSNRSystemID. 2. Selectingappropriatelocationsandmountingthedevice(s). 3. PerformingfinalICMSconfiguration. RequiredMaterials(NotSupplied) Thefollowingmaterials/toolsarerequiredforinstallation,butarenotsupplied:
Generaltoolkit(screwdrivers,powerdrill,etc.) ProgrammingtheSystemID FortheSNRstofunctioninawirelesssystem,eachmustcommunicatewithanearbyTransceiver(TRV)orMSIHub.Eachwireless networkshouldhaveauniqueSystemIDthatenablesallwirelesscomponentswiththatIDtocommunicatewitheachother. 1. OpentheWirelessSNRbygentlypressingonthebaselockingtab(1)andremovingthecover,andtheninserttwoAAalkaline 1.5Vbatteries(2)(HeatTimerp/n02000800). NOTE:Besuretoinstallthebatteriesintheproperdirection. 4 3 2 1 2. ObservetheWirelessSNRstatusindicators(3).IftheLEDsareblinkingeverysecondafterinstallingthebatteries,theSystemID isnotset(bydefault,thefactorysettingisthattheSystemIDisnotset). NOTE:IftheLEDsarenotblinking,verifythebatteriesaregoodandareinstalledcorrectly.Ifthebatteriesaregoodandthe LEDsarenotblinking,theSystemIDhasalreadybeenset.IftheSystemIDisknown,continuewithMountingtheWireless SNRonpage 7.IftheSystemIDisnotknown,theSystemIDmustbeclearedusingthefollowingsteps:
b. PressandholdtheModebutton(4)whilereinstallingthebatteries.ContinueholdingtheModebuttonuntiltheWireless a. RemovethebatteriesfromtheWirelessSNR. SNRstatusindicators(3)startblinkingoncepersecond. c. ContinuewithStep 3. HeatTimerCorp. 059049-00 Rev. 6WirelessSNRInstallationandOperationManual 3. RemovethebatteriesfromtheWirelessSNR,andthenprogramtheWirelessSNRSystemIDusingoneofthefollowingthree methods:
ProgramtheSystemIDWirelesslyusingaTransceiverorMSIHub NOTE:Transceiversoftwaremustbeversion13orabove. a. EnsuretheTransceiverorMSIHubhasbeenpoweredonandhasalreadybeenprogrammedwiththeSystemID.Observe theMSIHubstatusLEDs(1).IfthestatusLEDsarenotblinking,orareblinkingonlyonceevery15seconds,aSystemID hasbeenprogrammed.IftheLEDsareblinkingrapidly(oncepersecond),aSystemIDhasnotbeenprogrammed. 1 2 MSIHub b. PressandholdtheSystemIDSet/ResetbuttonontheMSIHub(2)orTransceiverfor5secondsoruntiltheredLEDstarts blinking. NOTE:TheSystemIDSet/ResetbuttonislocatedontheboardfortheTransceiver. c. InsertthebatteriesintotheWirelessSNRandobservethesensorsredandgreenstatusLEDs.WhentheLEDsstop blinking,thesensorisprogrammedandreadytobemounted. d. AftertheSystemIDhasbeenprogrammed,presstheSystemIDSet/ResetbuttonontheMSIHuborTransceivertoreturn thedevicetonormaloperation. e. ContinuewithMountingtheWirelessSNRonpage 7. ProgramtheSystemIDbyConnectingWirelessSNRtotheMSIHub a. EnsuretheMSIHubhasbeenpoweredonandhasalreadybeenprogrammedwiththeSystemID.ObservetheMSIHub statusLEDs(1).IfthestatusLEDsarenotblinking,orareblinkingonlyonceevery15seconds,aSystemIDhasbeen programmed.IftheLEDsareblinkingrapidly(oncepersecond),aSystemIDhasnotbeenprogrammed. 3 1 MSIHub 2 4 WirelessSNR 5 b. ConnecttheprovidedblackMSIRJ11communicationscable(2)totheprogrammingconnectionontheMSIHub(3)and WirelessSNR(4). CAUTION TheblackMSIRJ11communicationscable(provided)MUSTbeusedwhenconnectingtheMSIHub totheWirelessSNR.UsinganyothercablemayresultindamagetotheMSIHuband/orthe WirelessSensor/Transceiver. c. InsertthebatteriesintotheWirelessSNRandobservethesensorsredandgreenstatusLEDs(5).WhentheLEDsstop blinking,thesensorisprogrammedandreadytoinstall. d. DisconnecttheWirelessSNRfromtheMSIHub,andthencontinuewithMountingtheWirelessSNRonpage 7. 059049-00 Rev. HeatTimerCorp. InstallationInstructions7 ProgramtheSystemIDusingtheHandHeldWirelessProgrammer a. SetthedesiredSystemIDintheHandHeldWirelessProgrammer.RefertotheHandHeldWirelessProgrammermanual b. AftertheSystemIDisset,pressthe[Mode]buttontoreturntothemainmenu,selectConfigDevices,andthenpress c. SelectSystemID,andthenpress[Enter/].TheSystemIDcurrentlyprogrammedintotheWirelessProgrammeris d. InsertthebatteriesintotheWirelessSNRandthenconnectthephonecablefromtheWirelessProgrammertothe sensorbeingprogrammed.PressFtoloadtheSystemIDintotheWirelessSNR. e. WhenACKisdisplayedontheWirelessProgrammerscreen,thisisconfirmationthattheWirelessSNRhasacceptedthe SystemID.VerifythatthesensorsredandgreenstatusLEDshavestoppedblinking. f. DisconnecttheWirelessSNRfromtheWirelessProgrammer,andthencontinuewithMountingtheWirelessSNRon forinstructions.
[Enter/]. displayed. page 7. MountingtheWirelessSNR NOTE:TheSystemIDmustbeprogrammedpriortomountingtheWirelessSNR.EnsurethestepsprovidedinProgrammingthe SystemIDonpage 5havebeencompletedbeforecontinuing.TheWirelessSNRcovershouldalreadyberemovedandthebatteries installed. 1. SelectanappropriatelocationtomounttheWirelessSNR.Thelocationmustmeetthefollowingminimumrequirements:
Thelocationshouldbeonawallthatwillrepresentthecurrentlivingspacetemperature(forexample:inthelivingroom, 5 feet(1.5meters)highonaninteriorwall). Themountingsurfaceshouldbeflatandstrongenoughtoholdtheweightofthedevice. DONOTmountthedeviceinalocationwhereitwillbeexposedtoheating,cooling,orhumiditysources(suchasnear radiators,heating/coolingvents,windows,doors,orinakitchenorbathroom. 2. Markthemountinglocationthroughthetwomountingholes(1)intheWirelessSNRbase,andthensecuretheWirelessSNRin placeusingthesuppliedscrewsandwallanchors. 1 1 3. SnapthecoverbackontotheWirelessSNR. 4. ContinuetoPerformingtheICMSConfigurationonpage 7whenalldeviceshavebeenmounted. PerformingtheICMSConfiguration AftertheWirelessSNRhasbeenconfiguredandinstalled,itmustbeconfiguredinICMS. 1. WritethelocationoftheWirelessSNRontheIDcardprovidedwiththedevice(forexample,Apt.5A). 2. Accesswww.HTControls.comandlogin. 3. ConfigureICMSwiththeapplicableWirelessSNRinstallationdata(deviceID,name,type,andlocation). 4. AftertheICMSconfigurationiscomplete,logoutofICMS. HeatTimerCorp. 059049-00 Rev. 8WirelessSNRInstallationandOperationManual DetailedOperation ControlTheory TheHeatTimerWirelessNetworkSensorSystemisdesignedtobeusedinavarietyoflargebuildings,gardenapartments,andin retrofitapplications.Thisgivesboththeaccuracyandflexibilityrequiredtomonitorthosebuildings'temperatures(givingthecontrol morepowertosavefuelwhilekeepingspacetemperaturesatcomfortablelevels).Thesystemeasestheinstallationofspacesensors inbuildingswereitwouldbedifficultorcostprohibitiveutilizingothermeans,andgivesHeatTimerPlatinumcontrolsaccesstothe wirelesssensordata,whichitlogsandusesformonitoringandfinetuningitsoperation. Theprimaryintegralcomponentsofthesystemare:theMSIHub,Transceivers(TRV),WirelessSensors(SNR),andWireless TemperatureModules(WTM).TheSNRscommunicatetheirinformationtoanearbyTRVordirectlytoanMSIHub.Datareceivedbya TRVistransmittedeithertoanotherTRVortotheMSIHub.AlldatareceivedbytheMSIHubiscommunicatedtothePlatinumcontrol. Troubleshooting Symptom PossibleCause RecommendedAction BothredstatusLEDs(orallthreeLEDs)are continuouslyblinking. SystemIDhasnotbeenconfigured. StatusLEDsarenotblinkingafterthe batteriesareinstalled. Batteriesnotinstalledcorrectly,orare weakordrained. SystemIDisalreadyconfigured. Dataisnotbeingtransmittedorreceived bytheWirelessSNR. Batteriesweakordrained. ConfiguretheSystemID.IftheLEDsare stillblinkingaftertheSystemIDhasbeen configured,contactCustomerSupport. Verifythebatteriesaregoodandare installedcorrectly(checkthepolarity diagramonthebase). IftheSystemIDhasbeenpreviously configuredandisknown,noactionis required. IftheSystemIDisnotknown,reconfigure theSystemID. ReplacebothAAalkalinebatteries
(HeatTimerp/n02000800). 059049-00 Rev. HeatTimerCorp. WirelessSystemInformation InstallationAddress: __________________________________________________________________ WirelessSystemID: __________________________________________________________________ WirelessSystemInformation9 Locations:
1 2 3 4 5 6 7 8 9 10 Transceiver Transceiver Transceiver Transceiver Transceiver Transceiver Transceiver Transceiver Transceiver Transceiver 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor Sensor ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
ID#
HeatTimerCorp. 059049-00 Rev. 10WirelessSNRInstallationandOperationManual Notes 059049-00 Rev. HeatTimerCorp. Notes11 Notes HeatTimerCorp. 059049-00 Rev. WARRANTIES AND LIMITATIONS OF LIABILITY AND DAMAGE: Heat-Timer Corporation warrants that it will replace, or at its option, repair any Heat-Timer Corporation manufactured product or part thereof which is found to be defective in material workmanship within one year from the date of installation only if the warranty registration has been properly filled out and returned within 30 days of the date of installation. Damages to the product or part thereof due to misuse, abuse, improper installation by others or caused by power failure, power surges, fire, flood or lightning are not covered by this warranty. Any service, repairs, modifications or alterations to the product not expressly authorized by Heat-Timer Corporation will invalidate the warranty. Batteries are not included in this warranty. This warranty applies only to the original user and is not assignable or transferable. Heat-Timer Corporation shall not be responsible for any maladjustments of any control installed by Heat-Timer Corporation. It is the users responsibility to adjust the settings of the control to provide the proper amount of heat or cooling required in the premises and for proper operation of the heating or cooling system. Heat-
Timer Corporation shall not be required to make any changes to any building systems, including but not limited to the heating system, boilers or electrical power system, that is required for proper operation of any controls or other equipment installed by Heat-Timer Corporation or any contractor. Third Party products and services are not covered by this Heat-
Timer Corporation warranty and Heat-Timer Corporation makes no representations or warranties on behalf of such third parties. Any warranty on such products or services is from the supplier, manufacturer, or licensor of the product or service. See separate Terms and Conditions of Internet Control Management System (ICMS) services, including warranties and limitations of liability and damages, for ICMS services. THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED AND HEAT-TIMER CORPORATION SPECIFICALLY DISCLAIMS ANY AND ALL WARRANTIES OF MERCHANTABILITY FOR A PARTICULAR PURPOSE. UNDER NO CIRCUMSTANCES SHALL HEAT-TIMER CORPORATION, ITS AUTHORIZED REPRESENTATIVES, AFFILIATED OR SUBSIDIARY COMPANIES BE LIABLE FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES, EXCEPT AS SPECIFICALLY STATED IN THESE TERMS AND CONDITIONS OF SALE. THE SOLE REMEDY WITH RESPECT TO ANY PRODUCT OR PART SOLD OR INSTALLED BY HEAT-TIMER CORPORATION SHALL BE LIMITED TO THE RIGHT TO REPLACEMENT OR REPAIR F. O. B. FAIRFIELD, NJ. HEAT-
TIMER CORPORATION SHALL NOT BE LIABLE OR RESPONSIBLE FOR LOSS OR DAMAGE OF ANY KIND RESULTING FROM DELAY OR INABILITY TO DELIVER FOR ANY REASON, INCLUDING BUT NOT LIMITED TO FIRE, FLOOD, LIGHTNING, POWER FAILURE OR SURGES, UNAVAILABILITY OF PARTS, STRIKES OR LABOR DISPUTES, ACCIDENTS AND ACTS OF CIVIL OR MILITARY AUTHORITIES. 20 New Dutch Lane, Fairfield, NJ 07004 973-575-4004 Fax 973-575-4052 http://www.heat-timer.com 059049-00 Rev.