Users Manual MC13H & MM13H series CONTENTS 1. Safety Instructions.....4 2. Regulatory Information.....5 3. Precautions.....6 4. Before setting up.......7 5. Features & checking the products......8 Features of Lumimed series...8 Checking the products.8 6 Setting up the LCD Monitor.......9 Features of Connectors.....9 Description of Connectors.....9 Connecting the LCD Monitor...10 Warm-up Time....10 7. Adjusting of OSD Menu....11 Features of OSD Controls....11 Description of Control ports..11 OSD Operation...12 8.Adjusting the Viewing angle..13 9.Appendix......14 2 Safety Instructions Symbol Explanation RISK OF ELCTRIC SHOCK DO NOT OPEN CAUTION !
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER(OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL MEDICAL EQUIPMENT 13XX E246477 WITH RESPECT TO ELECTRIC SHOCK.FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL60601-1, AND CAN/CSA C22.2 NO. 601.1 MEDICAL EQUIPMENT CERTIFIED FOR CANADA Grounding Reliability can only be achieved when the equipment is connected to an equivalent receptacle with marked Hospital Only or Hospital Grade Explanation of Graphical Symbols Attention, consult ACCOMPANYING DOCUMENTS The lightning flash with arrowhead symbol, within an equilateral triangle ,is intended to alert the be user to the presence of un-insulated dangerous voltage within the products enclosure that of may sufficient magnitude to constitute a risk of electric shock to persons Stand-by Switch. Press to turn the monitor on or off(Stand-by mode). Alternating Current 3 Regulatory Information FCC RF INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television receptions, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-. Reorient or relocate the receiving antenna.
-. Increase the separation between the equipment receiver.
-. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-. Consult the or an experienced radio /TV technician for help. CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. CE MARKING DECLARATION OF CONFORMITY This LCD Monitor complies with the requirements of the EC Directive 89/336/EECEMC Directive and 93/42/EEC - Medical Device directive The electro-magnetic susceptibility has been chosen at a level that gives correct operation in residential areas. Business and light industrial premises and small-scale enterprises, inside as well as outside of the buildings. All places of operation are characterized by connection to the public low voltage power supply system. Classification:
- Protection against electric shock: Class I
- Applied Parts No Applied Parts.
- Protection against harmful ingress of water: ordinary IPX0
- Mode of operation: Continuous
- Degree of safety in the presence of flammable anesthetics mixture with air or with oxygen or with nitrous oxide
- Not suitable for use in the presence of a flammable anesthetics mixture with air or with oxygen or with nitrous oxide. 4 Precautions Plug the power cord into a properly grounded outlet. There is the risk of electric shock. If you hear a noise or smell smoke from the view box or power cord, unplug the power cord immediately, and call service center. There is the risk of electric shock or fire Do not overload an electrical outlet with too many devices. There is the risk of fire Do not unplug from the outlet by pulling the power cord or when your hands are wet. Do not bend the power cord excessively or place heavy objects on it. Keep children and pets away from the power cord as they may cause damage the power cord. Do not use a damaged power cord or plug. Make sure the plug fits snugly into the outlet. Unplug the Power cord for isolation from supply if you use not monitor for a long time.. Do not expose this monitor to the direct sun-light. Do not allow any object or liquid to enter inside this monitor. There is the risk of electric shock, fire, or damage to the monitor Do not attempt to disassemble, unfix or modify the monitor. Keep the monitor away from high temperature, humidity and dust etc..
-> Operating environment Temperature : 10~40 degrees Celsius () Humidity : 10~80 relative humidity (%) Use a proper voltage/current level indicated. The device could be send back to the manufacturer for recycling or proper disposal after their useful lives. Alternatively the device shall be disposed in accordance with national laws after their useful lives. Equipment with signal input / signal output connectors should either indicate the connected equipment comply with IEC 60601-1 and / or IEC 60601-1-1 harmonized national standard or the combination should be evaluated. This medical monitor is designed for viewing medical X-Ray Images 5 Before setting up Before setting up the LCD monitor, please read this manual to help your understanding of the Monochrome TFT-LCD Monitor. Install the LCD Monitor on a flat place. Dont install in the place with much of water or moisture Put the LCD Monitor in a place with low humidity and a few of dust. Dont overload an electrical outlet with too many devices. There is the risk of fire. Dont expose the LCD monitor to the direct sun light. Keep the monitor away from high temperature. Do not place the monitor in hazardous position. NOTICE Please clean the panel and cabinet of monitor with a clean damp cloth and then wipe and dry with a clean soft cloth Please do not use volatile organic solvents such as alcohol, thinner, and benzenes when cleaning. These can be damaged to the front panel Do not attempt to service, modify or dismantle this product. Recommended service should be done at the prescribed intervals by Heeyoung Service engineer, Agent or a trained Technician. 6 Features & checking the products Features of Lumimed series High luminance & High contrast ratio Built-in 10-bit LUT Integrated Stable Brightness Control System OSD control for user control Digital Video Interface Video mode(CVBS,S-Video) support Narrow bezel design for space-saving Checking the products The following accessories are included in package. Check to see if they are enclosed with the monitor. If anything is missing or damaged, please contact your local dealer. Monitor TFT-LCD Monitor Accessory Box 15Pin D-sub cable Power Cord Power DC adaptor User Manual DVI-D Signal Cable RCA Cable S-Video cable 7 Setting up the LCD Monitor Feature of Connectors
<Landscape> <Portrait>
No Description of Connectors Name Cable Connections DC input Connect the DC jack of the Power adaptor DVI PC Video S-video Digital Video Interface connection from PC 15 Pin D-sub cable connection from PC Connect the RCA cable from the video system Connect the S-video cable from the video system 8 Setting up the LCD Monitor Connecting the LCD Monitor 1) Connect the DVI-D signal cable to the signal port of the Graphic Card in your computer. 2) Connect the D-sub signal cable to the signal port of the Graphic Card in your computer. 3) Connect the DC input cable to the DC input port on the rear side of the monitor 4) Connect the RCA,S-video cable to the video system like a DVD 5) Turn on the monitor with the power switch of the user control port. Plug & Play The adoption of the new VESA Plug & Play solution eliminates complicated and time consuming setup. It allows you to install your monitor in a Plug and Play compatible system without the usual manual hassles and confusion. Your PC system can easily identify and configure itself for use with your display. This monitor automatically tells the PC system its Extended Display Identification Data(EDID) using Display Data Channel(DDC) protocols so the PC system can automatically configure itself to use the flat panel display. All LCD monitors need time to become thermally stable whenever you turn on the monitor Warm-up Time After letting the monitor be turned off for a couple of hours. Therefore, to achieve more accurate adjustments for parameters, allow the LCD monitor to be Warmed up for at least 20 minutes before making any screen adjustments. 9 Adjusting of OSD MENU Features of OSD Controls LED MENU SELECT SOURCE - +
Description of Control ports
. Indicate Monitor power status by LED color Normal Operation : Green color Power Saving : Amber color Off Mode : off. Power on / off toggle button MENU Launch OSD Menu SELECT Menu select button. In Directly hot-key function, you can adjust Auto-balance for various input mode of PC system SOURCE Select the input signal source
- Menu shift button. Press the - button to decrease You can adjust directly Brightness with +/- button
+ Menu shift button. Press the + button to increase the brightness You can adjust directly Contrast with +/- button 10 Adjusting of OSD MENU OSD Operation BRIGHTNESS/CONTRAST COLOR COLOR CONTROL Brightness: Changes the overall light intensity of the images being displayed Contrast : Changes the ratio of light intensity between the brightness white and darkest black You can adjust brightness/contrast values that you want by this hot key The tone of color can be changed from blush-white to reddish-white. Color1 : Blue type Color2 : Red type User : You can adjust a color control. COLOR CONTROL : This function is used to Video mode SATURATION : Adjust color intensity of the VIDEO TINT : Adjust a color tone of the VIDEO SHARPNESS : Make image of the VIDEO looked sharper CLOCK/PHASE When image is not clear, you can use clock/phase menu. PHASE/CLOCK : Although automatically finds the optimum values of CLOCK and PHASE parameters as well As image position, it may be necessary for you to adjust those parameters manually. MICSELLANEOUS RECALL : Return to original status of factory mode. 11 OSD TIME OSD POSITION LANGUAGE OSD TIME : Shows the OSD TIME displays from 10 to 30 seconds. OSD POSITION : Moves the OSD MENU to the horizontal or vertical direction LANGUAGE : Select the language GAMMA ADJUSTMENT BYPA : Control the gamma value without using LUT 12 LINE: Control the gamma value without using LUT GSDF : Control the gamma value with using10bit LUT USER : Control the value INPUT SELECT INPUT SELECT : Select the input signal source. Please see the Input signal source of below order DSUB => DVI => CVBS => S-VIDEO => DSUB. Adjusting the Viewing angle
- For optimal viewing, it is recommended to look at the full face of the monitor 13 and then adjust the monitors height and angle to your own preference. Height ,Tilt ,Swivel
- You are able to adjust the monitors height up to 110mm, angle up to 35degrees right and left, 35 degrees upward
- Adjust the monitors height to the maximum. Rotation(Pivot) Function
- Rotate the panel 90 degree
-> Portrait : Turn clockwise.
->Landscape : Turn counter clockwise. NOTE
- Do not touch the LCD screen when you change the height or the angle.
- It may cause damage or break the LCD screen.
- Careful attention is required not to catch your fingers or hands when you change the height or the angle
<Swivel>
14 Appendix DVI-D Connector Pin Signal 1 2 3 4 5 6 7 8 C1 C4 T.M.D.S.Data2-
T.M.D.S.Data2+
T.M.D.S.Data2/4 Shield T.M.D.S.Data4-
T.M.D.S.Data4+
DDC Clock DDC Data N.C N.C N.C Pin 9 10 11 12 13 14 15 16 C2 C5 Signal T.M.D.S.Data1-
T.M.D.S.Data1+
T.M.D.S.Data1/3 Shield T.M.D.S.Data3-
T.M.D.S.Data3+
+5V Power Ground Monitor sense N.C N.C Pin 17 18 19 20 21 22 23 24 C3 Signal T.M.D.S.Data0-
T.M.D.S.Data0+
T.M.D.S.Data0/5 Shield T.M.D.S.Data5-
T.M.D.S.Data5+
T.M.D.S. Clock Shield T.M.D.S. Clock+
T.M.D.S. Clock-
N.C 15 Pin D-Sub Connector 15 Appendix Power-Saving Mode Mode LED Indicator Power Dissipation Normal Operation Power Saving Mode Off Mode Green Amber Off Normal consumption Less than 5W Less than 5W Display mode in PC mode 16 Appendix SPEC LCD ITEM DESCRIPTION 256Grey Colors(MM13H) 1000cd/m2(MM13H) 19.0 inch Size 0.294 x 0.294mm Type a-Si TFT active matrix Pixel Pitch Anti-Glare, Hard coating, 3H Surface 376 x 301mm Viewable Size 16.7M colors Color depth 250cd/m2 Brightness 1000:1(Typical) Contrast ratio 8ms(typical) Response time U/D 75 /85 ,L/R 80/80 Viewing 15-85KHz H-sync 50-80Hz V-sync VGA to SXGA Analog VGA to SXGA Digital Analog RGB(VGA) 15 Pin D-sub 24Pin DVI-D DVI RCA jack/Mini Din 4Pin Analog Video BNC jack x3 (Optional) BNC(Optional) Analog RGB(VGA) 0.7Vpp R,G,B DVI Analog Video BNC(Optional) Button Function Method DVI-D standard 1.0 S-Video,CVBS Composite(R,G,B SOG) MENU,SELECT,SELECT,POWER,+,_-
OSD Control VESA DDC-CI VESA standard 100x100mm AC 100-240, 50-60Hz DC12V, 6.67A Less than 5W Typical 50W Temperature 0C 40C Touch-panel(Resistive),Protection sheet 17 AC Input Adaptor Power Saving Consumption Frequency Resolution Input Terminal Input Signal Spec User control Plug & Play VESA Wall Mounting Power supply Operating Enviroment Optional Appendix Trouble Shooting What you see Suggested Actions Screen is blank and Make sure that the power cord is firmly connected and the LCD power indicator is off monitor is on. No signal message Make sure that the signal cable is firmly connected to computer Make sure that the computer is turned on The display image is too Adjust the brightness & contrast dark or too light Screen is blank and The monitor is using its power saving system.(DPMS) power indicator light is Move the computers mouse or press a key on the keyboard. steady red or blinks Contact HEEYOUNG Co., Ltd. 1048-8, SHINGIL-DONG DANWON-GU ANSAN-CITY KYUNGGI-DO, 425-839 KOREA Tel : 82-31-491-5506, Fax : 82-31-491-5509 Managing Directing Tel) 82-31-491-5585 B.H. Park Email) beam0223@lumimed.com R&D Division Director S.D. Lee Tel) 82-31-491-5507(103) Email) sdlee@lumimed.com Overseas Sales Department Tel) 82-31-491-5506(309) Manager Chris Soh Email) cooljh@lumimed.com Plant Tel) 82-31-495-3121(312) Manager W.S. Hong Email) wshong@lumimed.com Q.C Department Tel) 82-31-495-3121(313) Assistant Manager J.W. Kim Email) jwkim@lumimed.com P/N : 97M9500100 18