9292 Jeronimo Road Irvine, CA 92618-1905 HID FlexSmart 609X Series Readers INSTALLATION GUIDE 2007 HID Global Corporation. All rights reserved. February 1, 2006 Document Number 6090-900 Document Version A.0 FlexSmart 609X Series Installation Guide 6090A-901, A.0 Contents 1 2 3 Overview.......................................................................................................................... 3 Introduction ........................................................................................................... 3 1.1 Parts Included ....................................................................................................... 3 1.2 1.3 Specifications ........................................................................................................ 3 Mounting.......................................................................................................................... 4 Wiring............................................................................................................................... 6 Cable Types and Maximum Lengths..................................................................... 6 3.1 Connections .......................................................................................................... 7 3.2 3.3 Grounding ............................................................................................................. 7 Wiegand Output Timing ............................................................................................................. 8 ABA Track 2 Magnetic Stripe Output Timing........................................................................... 8 Regulatory................................................................................................................................... 8
.............................................................................................................................. 8
.............................................................................................................................. 8 FCC UL Models ......................................................................................................................................... 9 Contact ........................................................................................................................................ 9 Page 2 of 9 2007 HID Global Corporation. All rights reserved. February 1, 2007 FlexSmart 609X Series Installation Guide 6090A-901, A.0 1 Overview 1.1 Introduction The HID FlexSmart 609X series are RFID card readers based on MIFARE smartcard technology. They are encapsulated units designed to attach to a single-gang electrical box, suitable for both indoor and outdoor use. Data is output in either Wiegand or ABA track 2 (magstripe) formats, and is application dependent. Electrical connection is made via a 6-way detachable screw terminal block. Note: The format and function of the reader depends on the configuration loaded from a configuration card. 1.2 Parts Included First, unpack the contents and become familiar with the components. The following items will be included with FlexSmart readers:
Installation Guide 1. 2. MIFARE reader module 3. Fixing accessories 1.3 Specifications Supply Voltage Supply Current Input Output formats Operating Frequency Data Transmission Authentication Operating Temperature Non-Operating Temperature Operating Humidity Finish Dimensions Weight 9VDC to 16VDC (12VDC typical) 20 mA typical, 75mA peak 2 lines available Typical use: 1 line LED control, and 1 line buzzer control Application dependent Wiegand/ABA track 2 Application dependent 13.56MHz, 106k Baud Contactless ISO/IEC DIS 9792-2
-4F (-20C) to 131F (55C)
-40F (-40C) to 158F (70C) 5% to 95% condensing Black 3.39 x 3.39 x 1.18 (86 x 86 x 30 mm) 9 oz (250g) February 1, 2007 Page 3 of 9 2007 HID Global Corporation. All rights reserved. FlexSmart 609X Series Installation Guide 6090A-901, A.0 2 Mounting Figure 2-1 Overall Dimensions Figure 2-2 Back Plate Dimensions 2007 HID Global Corporation. All rights reserved. February 1, 2007 Page 4 of 9 FlexSmart 609X Series Installation Guide 6090A-901, A.0 Figure 2-3 Attaching Backplate Figure 2-4 Install Reader February 1, 2007 Page 5 of 9 2007 HID Global Corporation. All rights reserved. FlexSmart 609X Series Installation Guide 6090A-901, A.0 3 Wiring Figure 2-5 Fascia Label 3.1 Cable Types and Maximum Lengths The 609x series readers require a minimum supply voltage of 9.0 VDC at the reader. Voltage drops, caused by the cable resistance, can be compensated by increasing the power supply voltage, provided the maximum supply voltage (16.0 VDC) is not exceeded at the reader. CAUTION: THE READER SUPPLY VOLTAGE MUST NOT EXCEED 16.0 VDC. CAUTION: DO NOT USE CABLES WITH GAUGES SMALLER THAN 24 AWG:
The following are recommended cable types and maximum cable lengths for a cable connecting the power supply to the reader. Maximum Cable Length 200 (61 m) 300 (91 m) 500 (152 m) Cable Type 24 AWG (0.51mm), overall foil shield, Belden 9533 series or equivalent. 22 AWG (0.64mm), overall foil shield, Alpha Wire 5192C series or equivalent. 18 AWG (1.02mm), overall foil shield, Alpha Wire 5382C series or equivalent. Page 6 of 9 February 1, 2007 2007 HID Global Corporation. All rights reserved. FlexSmart 609X Series Installation Guide 6090A-901, A.0 System data line terminations may affect the cable required. Contact your system manufacturer for exact requirements. Installation should be in accordance with National Electric Code ANSI/NFPA 70. Note: The cable should have a minimum of four cores (two for power and two for output data). If the readers input control lines are required, then the cable will need to have extra one or two cores depending on the inputs required. 3.2 Connections There is a 6-way connector with detachable terminal block at the rear of the unit. Wire this connector according Pin Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1 Reader Wiring LED control input Beeper control input Wiegand data 0/Strobe Wiegand data 1/Data Power supply 0V (ground) Power supply +VE Figure 3-1 Wiring Connections Pins 5 and 6, (LED and buzzer control inputs) may be left unconnected if they will not be used. The cable shield/drain should not be connected to anything at the reader end. 3.3 Grounding At the controller end of the cable the shield/drain should be connected directly to an earth ground. An earth ground can be established by driving a copper clad ground rod into the earth. If a direct connection to a ground rod is not possible, connect the shield/drain to an earth grounded cold water metal pipe or steel frame (building beam) that connects to earth. Make certain that the DC resistance between your established earth ground and the system ground is 50 ohms or less. Do not connect to a copper fire sprinkler system because this may have non-conductive couplings. Note: The shield/drain should be connected at the power supply. Connection of the shield/drain to an earth ground will provide greater ESD protection of the reader. February 1, 2007 Page 7 of 9 2007 HID Global Corporation. All rights reserved. FlexSmart 609X Series Installation Guide 6090A-901, A.0 Wiegand Output Timing ABA Track 2 Magnetic Stripe Output Timing Regulatory FCC UL This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This Proximity Reader is intended to be powered from a limited power source output of a previously certified power supply. This Reader is intended to be used with UL 294 Listed Control Equipment. Page 8 of 9 2007 HID Global Corporation. All rights reserved. February 1, 2007 FlexSmart 609X Series Installation Guide 6090A-901, A.0 Models 6090 HID Format MIFARE Euro Reader 6091 Custom MIFARE Euro Reader 6092 Custom DESFire Euro Reader Contact Americas HID Corporation (California, USA) support: tech@hidcorp.com main: (949) 598-1600 support: 1-800-237-7769 fax number: (949) 598-1690 Europe, Middle East and Africa HID Corporation, Ltd. (Haverhill, UK) support: eusupport@hidcorp.com main: +44 (0) 1440 714 850 support: +44 (0) 1440 711 822 fax number: +44 (0) 1440 714 840 Asia-Pacific HID Asia Pacific Ltd. (Hong Kong) support: asiasupport@hidcorp.com main: (852) 3160 9800 support: (852) 3160 9802 fax number: (852) 3160 4809 February 1, 2007 Page 9 of 9 2007 HID Global Corporation. All rights reserved.