REV SHEET REV DESCRIPTION 1 INITIAL PROTOTYPE DATE APPROVED 032603 CDSHEA REVISIONS 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 1 1 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 REV DO NOT SCALE DRAWING IRVINE, CALIFORNIA REV STATUS OF SHEETS SHEET EXCEPT AS NOTED DIM ARE IN INCHES PER ANSI Y14.5
.XX .XXX ANGLES
+/-.01 +/-.005 +/-1 MATERIAL:
FINISH:
APPROVALS DATE DRW:
CHK:
APVD:
APVD:
MMDDYY MMDDYY MMDDYY MMDDYY DWG DESCRIPTION MANUAL, INSTALLATION, iCLASS Handspring 6140-900 DWG NUMBER CAGE CODE REV 2 SHEET: 0 of 2 SIZE A SCALE: N/A DATE 1 REV 032603 REVISIONS DESCRIPTION INITIAL PROTOTYPE NOTE: Cover sheet is for Revision Control only, and is not to be sent with document. APPROVED CDSHEA REV STATUS OF SHEETS SHEET EXCEPT AS NOTED DIM ARE IN INCHES PER ANSI Y14.5 REV SHEET 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 1 1 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 REV DO NOT SCALE DRAWING IRVINE, CALIFORNIA
.XX .XXX ANGLES
+/-.01 +/-.005 +/-1 MATERIAL:
FINISH:
APPROVALS DATE DRW:
CHK:
APVD:
APVD:
MMDDYY MMDDYY MMDDYY MMDDYY DWG DESCRIPTION MANUAL, INSTALLATION, iCLASS Handspring 6140-900 DWG NUMBER CAGE CODE REV 2 SHEET: 1 of 2 SIZE A SCALE: N/A Install Manual 6140-900 Rev 2 iCLASS Handspring Installation Manual ASSA ABLOY An ASSA ABLOY Group company _____________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Page 2 of 2 Web page, E-mail - www.hidcorp.com iCLASS Handspring Installation Manual 6140-900 Rev 2 The 6140A iClass Handspring Module is intended to be used plugged into the accessory slot of a Handspring Visor Prism PDA supplied by the user. The Read IT Software provided on CDROM is intended for use with Palm OS v.3.5 in the PDA. Before you use the ReadIT Software read this manual carefully to ensure correct use. The ReadIT software controls the iClass Handspring Module. Via this Module the Read IT Software allows you to perform read and write operations to a secure section of memory of the iClass Contactless Smart Cards. This section of memory consists of the entirety of Page 7. Page 7 must be protected by the HID default authentication key in order to be accessible by the ReadIT software. Assure that the iCLASS Handspring Module is in the Accessory Slot. Operation in portable mode:
In the home screen , press Read IT Poll. Read should appear. a) Press the Power On button (black button with green dot). b) c) Press the Read box twice. No Card Detected should appear and the box should now show Stop. d) The unit is now transmitting and will indicate the ID number and contents of page 7, if any, if a card is held in proximity to the unit. If the card is adequately configured (8x2KS page 7 protected by the HID default key), the Unique Serial Number of the card and the contents of page 7 will be displayed on the screen. The information will also be automatically stored in a local database. Operation in the docking station:
a) Place the Handspring PDA, with iCLASS Handspring Module installed, in the docking station. b) Plug the wall transformer low voltage output plug into the docking station computer port plug. c) Plug the wall transformer into a 120 VAC outlet. d) The PDA power-on green LED should be flashing. e) Perform steps a) through d), above. Write to a card:
After reading a smart card, you may modify its contents by editing the screen and clicking on Write. The database will be automatically updated with the new information. Access to a Record Delete a Record:
Each Smart card read is entered as a record in the database. Each record is labeled with the unique Serial Number of the card. The record can be accessed by clicking on the corresponding SN in the main screen of the application. Its contents will appear. You may return to the main screen by clicking Done or you may erase the record by clicking the Delete button and confirming it by clicking OK. You can also write to the card by clicking Write. Note: Operations on the RF link between cards a Springboard module occur only when clicking on the read or Write buttons. Other operations may be conducted without the presence of a Smart Card in the vicinity of the reader. ASSA ABLOY An ASSA ABLOY Group company _____________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Page 3 of 2 Web page, E-mail - www.hidcorp.com iCLASS Handspring Installation Manual 6140-900 Rev 2 FCC Compliance Statements:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. ASSA ABLOY An ASSA ABLOY Group company _____________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Page 4 of 2 Web page, E-mail - www.hidcorp.com iCLASS Handspring Installation Manual 6140-900 Rev 2