iCLASS SE Biometric/
iCLASS SE Display Reader RKCL40, RPKCL40, RKCLB40 SRD MODEL: RPKCL40E, RKCLB40E PLT-02738 A.0 Parts 1 - Reader and base plate assembly 1 - Installation guide 2 - Terminal connector 4 - M3.5 mm x 12 mm Phillips machine screw 4 - #6-32 x .375 Phillips self-tapping machine screw 4 - #6 x 1.5 Phillips sheet metal screw 3 - #6-32 x .4375 Spanner security screw, anti-tamper (black) 3 - #6-32 x .4375 Phillips security screw (black) 1 - Mounting Gasket Recommended Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield (Belden 3108A or equivalent) - RS-485 + power Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm] Over-All Shield, (Alpha 1296C or equivalent) - Wiegand + power DC power supply Metal or plastic double-gang junction box Reader spacer when using metal junction boxes - see How to Order Guide Security tool (for spanner security screw, anti-tamper) HID 04-0001-03 Specifications PRODUCT BASE PART NUMBER INPUT VOLTAGE
(VDC) Standby AVG1 CURRENT Maximum AVG2 PEAK3 OPERATING TEMPERATURE CABLE LENGTH UL REF NUMBER SRD Model RKCL40 RPKCL40 RKCLB40 923N 923P 924N 12VDC 150mA 185mA 250mA 165mA 215mA 275mA
-4 to 149 F
(-20 to 65 C) 14 to 122 F
(-10 to 50 C) Wiegand and RS-485 500 ft - 22 AWG (152 m) 300 ft - 24 AWG (91 m) RPKCL40Ex1x2x3 RPKCL40E RKCLB40Ex1x2x3 RKCLB40E 1 Standby AVG - RMS current draw without a card in the RF field. 2 Maximum AVG - RMS current draw during continuous PIV card reads. Not evaluated by UL. 3 Peak - highest instantaneous current draw during RF communication. UL Reference Number Deciphering K = Black, x1 Reader Colors:
x2 Wiring:
T = Terminal x3 Communications: R = Module hidglobal.com INSTALLATION GUIDEAn ASSA ABLOY Group brand Installation 1 Mounting Attach Backplate and Mounting Gasket to Junction Box. Install gasket Wall backplate 2 Wiring Beeper GRN LED GND
+VDC DRAIN RED HOLD GPIO1 GP102 OC/TMPR DATA1/CLK DATA2/DATA GPIO3 GPIO4 Junction box not included. Mounting holes for US double-
gang electrical boxes. Reverse Configuration Rotating the backplate 180 allows for placing the LCD display on left and the reader on right. See Section B Alternate Reader Assembly for instructions, before proceeding to Section 2:
Wiring. Terminal Reader
(Terminal block and module position varies) H O L D R E D D R A N I
+
V D C G N D G R N L E D B e e p e r G P O 4 G P O 3 I I G P 1 0 2 G P O 1 I
/
O C T M P R D A T A 1 C L K
/
D A T A 2 D A T A
/
P1 P2 ATTENTION Observe precautions for handling ELECTROSTATIC SENSITIVE DEVICES Note: Previous iCLASS readers had reversed RS-485 wiring ( P2-7 & P2-6 - A & B). When upgrading, ensure proper connections as defined below. Pigtail Yellow Orange Black Red Drain Brown Blue Terminal P1-1 P1-2 P1-3 P1-4 P1-5 P1-6 P1-7 Description Beeper Input LED Input (GRN) Ground (RTN)
+VDC Unused LED Input (RED) Hold Input Pigtail Red / Green Tan Violet White Green Pink Gray Terminal Description P2-7 P2-6 P2-5 P2-4 P2-3 P2-2 P2-1 GPIO1 (RS232-T / RS485-FDX/HDX-A) GPIO2 (RS232-R / RS485-FDX/HDX-B)
*Open Collector Output / Tamper
**Wiegand Data 1 / Clock
**Wiegand Data 0 / Data GPIO3 (RS485-FDX-Z) GPIO4 (RS485-FDX-Y)
*Tamper Output - When activated, output synchronizes to ground (default).
**Dependent upon reader configuration. See the HTOG for Wiegand and Clock-in-Data configurations. hidglobal.com INSTALLATION GUIDEAn ASSA ABLOY Group brand 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.RKCL40E, RPKCL40E, RKCLB40ESRD Model: RPKCL40E, RKCLB40EiCLASS SE Biometric/iCLASS SE Display 3 Attach to Backplate Mount the Reader Assembly (Reader, LCD Assembly, and reader backplate) to the wall backplate. Standard Configuration: Slide Reader Assembly towards the right to lock. Alternate Configuration: Slide Reader Assembly to the left to lock. Install Security screws. 4 Power & Testing hidglobal.com INSTALLATION GUIDEAn ASSA ABLOY Group brand 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.RKCL40E, RPKCL40E, RKCLB40ESRD Model: RPKCL40E, RKCLB40EiCLASS SE Biometric/iCLASS SE Display A Biometric Reader Proper Usage Ensure a good quality Contact:
Do not press too hard Do not move during image acquisition Leave your finger on the sensor at least 2 seconds Do not slide or roll your finger across the sensor Cleaning For optimum performance, it is recommended that the user clean the bio-reader periodically. The use of a dry cloth is recommended to clean the acquisition surface. Caution: Acidic liquids, alcohol or abrasive materials are prohibited. In order not to scratch the surface, remove all dust and residue with gentle movements. Acquisition Surface B Credential Presentation Best Practices To ensure a successful read of a card:
1. Hold card between the thumb and index finger. 2. Present the card so that the index finger creates a spacing between the card and the reader face. Do not place the card flat on the reader. 3. Place the card parallel to the reader form factor. Do not angle to the right or left 4. Place the card parallel to the reader face. Do not angle the card up or down from the reader face. hidglobal.com INSTALLATION GUIDEAn ASSA ABLOY Group brand 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.RKCL40E, RPKCL40E, RKCLB40ESRD Model: RPKCL40E, RKCLB40EiCLASS SE Biometric/iCLASS SE Display E Alternate Reader Assembly The following steps reconfigure the reader assembly to position the LCD Display component on the left side of the assembly. Standard Configuration 1. Disassemble the Reader. Remove the Reader from the backplate. Carefully unplug the ribbon cable from the module in the back of the Reader. Caution: Do not pull on the ribbon cable as this may damage the connection to the connector. Remove the LCD Display from the backplate. Gently pull the ribbon cable through the backplate. Reader LCD Display Alternate Configuration Ribbon cable Reader Backplate LCD Display Reader Reader LCD Display 2. Reassemble with the LCD Display on the left side of the assembly. Rotate the backplate so that the large cutout for the power cable is on the left Gently route the ribbon cable back through the backplate slots, as shown below Plug the ribbon cable back into the module (back of Reader) and ensure module is fully seated into the reader Attach the LCD Display to the backplate (this must be installed first, as the Reader will fit slightly over the LCD Display) Attach the Reader to the backplate (power cable must be threaded through the large square cutout on the backplate) Return to Section 2. Test card Ribbon cable Reader Backplate LCD Display Reader hidglobal.com INSTALLATION GUIDEAn ASSA ABLOY Group brand 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.RKCL40E, RPKCL40E, RKCLB40ESRD Model: RPKCL40E, RKCLB40EiCLASS SE Biometric/iCLASS SE Display Regulatory The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID. If the FCC & IC ID is not visible, when the module is installed inside another device, then the final assembly label must contain the FCC and IC ID numbers with a statement such as follows: Contains Transmitter Module with FCC ID JQ6-ICLASSBTM and IC ID 2236B-ICLASSBTM. UL Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be used with listed
(UL294) control equipment. Suitable for outdoor use. Only Wiegand and RS-485 communications have been evaluated by UL. FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Any changes or modifcations to this device not explicitly approved by the manufacturer could void your authority to operate this equipment. Indala Prox products RP10EL, RP15EL, RP30EL, RP40EL and RPK40EL are certified for FCC, Canada Radio Certification and CE Marking only. Canada Radio CeRtiFiCation This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Ce MaRking HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC. HID Global dclare par la prsente que ces lecteurs proximit sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE. A HID Global, por meio deste, declara que estes leitores de proximidade esto em conformidade com as exigncias essenciais e outras condies da diretiva 1999/5/EC. HID Global besttigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfllen. HID Global dichiara che i lettori di prossimit sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC. Download copies of the R&TTE Declaration of Conformity (DoC) at http://www.hidglobal.com/certifications. BRaziL Compliance Statement Este produto est homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resoluo 242/2000, e atende aos requisitos tcnicos aplicados. Para maiores informaes, consulte o site da ANATEL - www.anatel.gov.br This product is homologated at ANATEL according to procedure regulated by Resolution 242/2000, and it complies with the applicable technical requirements. For more information, consult ANATEL website - www.anatel.gov.br RF Warning Statement Per Article 6 of Resolution 506, equipment of restricted radiation must carry the following statement in a visible location:
Este equipamento opera em carter secundrio, isto , no tem direito a proteo contra interferncia prejudicial, mesmo de estaes do mesmo tipo, e no pode causar interferncia a sistemas operando em carter primrio. This equipment operates in secondary character, meaning it does not have the right of protection against harmful interference, even against those the same character, and it cannot cause any interference to systems operating in the primary character. hidglobal.com INSTALLATION GUIDEAn ASSA ABLOY Group brand 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.RKCL40E, RPKCL40E, RKCLB40ESRD Model: RPKCL40E, RKCLB40EiCLASS SE Biometric/iCLASS SE Display iCLASS Keypad Readers FOTO SELO ANATEL Fabricante: HID Global Corporation Modelo: iCLASS SE RK40E, multiCLASS RPK40E Este produto esta aprovada pela Anatel, de acordo com os procedimentos regulamentados pela Resoluo n 242/2000 e atende aos requisitos tcnicos aplicados. Este equipamento opera em carter secundrio, isto , no tem direito a proteo contra interferncia prejudicial, mesmo de estaes do mesmo tipo, e no pode causar interferncia a sistemas operando em carter primrio iCLASS Non-Keypad Readers FOTO SELO ANATEL Fabricante: HID Global Corporation Modelo: iCLASS SE R10, multiCLASS RP10E, multiCLASS RP30E iCLASS SE R40E, multiCLASS RP15E, multiCLASS RP40E Este produto esta aprovada pela Anatel, de acordo com os procedimentos regulamentados pela Resoluo n 242/2000 e atende aos requisitos tcnicos aplicados. Este equipamento opera em carter secundrio, isto , no tem direito a proteo contra interferncia prejudicial, mesmo de estaes do mesmo tipo, e no pode causar interferncia a sistemas operando em carter primrio hidglobal.com INSTALLATION GUIDEAn ASSA ABLOY Group brand 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS are trademarks or registered trademarks of HID Global, or its licensors, in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice.RKCL40E, RPKCL40E, RKCLB40ESRD Model: RPKCL40E, RKCLB40EiCLASS SE Biometric/iCLASS SE Display taiwan According to Administrative Regulations on Low Power Radio Waves Radiated Devices Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices. Japan MiC
(AC-) RFID SingapoRe Complies with IDA Standards DA103548 koRean kCC R10E, R15E, R30E, and R40E RP10E, RP15E, RP30E and RP40E RK40E RPK40E RFID:13.56 MHz RFID:13.56 MHz RFID: 10m 47.544mv X-tal AM RFID:13.5607 MHz, LPD:125 KHz RFID:13.56 MHz, LPD:125 KHz RFID: 10m 47.544mv. LPD:3 m 500 /m X-tal (13.56MHz) Resonator(125kHz) AM(13.56MHz), FSK(125kHz) DC 16.0V A1D HID Global Americas & Corporate 611 Center Ridge Drive Austin, TX 78758 USA Support: 866-607-7339 949-732-2120 Fax:
Asia Pacific 19/F 625 King's Road North Point, Island East Hong Kong Support: 852-3160-9833 852-3160-4809 Fax:
Europe, Middle East & Africa Phoenix Road Haverhill, Suffolk CB9 7AE England Support: 55 11 5514-7100 55 11 5514-7109 Fax:
For additional offices around the world, see www.hidglobal.com corporate offices. HID Global Customer Support: www.hidglobal.com/support Equipment 8T29 ACC Control Reader General Signaling Equipment hidglobal.com An ASSA ABLOY Group brandINSTALLATION GUIDERKCL40E, RPKCL40E, RKCLB40ESRD Model: RPKCL40E, RKCLB40EiCLASS SE Biometric/iCLASS SE Display