S m a r t I D b y installation instalacin installation instalao installation installazione S10 / SK10 SP10 / SPK10 Add Picture OPERATING TEMPERATURE CABLE DISTANCE PRODUCT BASE PART NUMBER INPUT VOLTAGE CURRENT AVERAGE PEAK S10 SK10 HID / AWID Prox SP10 SPK10 Indala Prox SP10 SPK10 8030 8031 8100 8101 8140 8141 5-24 VDC 600 mW
?? mA 1000 mW
?? mA
-22 - 140F
(-30 - 60 C) 5-24 VDC 1400 mW
?? mA 2100 mW
?? mA
-22 - 140F
(-30 - 60 C) Wiegand = 500 ft (153 m) - 18 AWG
- 20 AWG
- 22 AWG 300 ft (91 m) 200 ft (61 m) Clock -and-Data 82 ft (25 m)
- 22 AWG 5-24 VDC 1300 mW
?? mA 1600 mW
?? mA
-22 - 140F
(-30 - 60 C) RS232 = 50 ft (15.24 m) RS485 = 4000 ft (1,219.2 m) paRts 1 - SmartID Reader 1 - Installation Guide 2 - 3.5 mm x .6 pitch x16 mm Phillips machine screws 2 - .138-32 x .625 Phillips machine screws 2 - .138-20 x 1.5 FL-82 Phillips AB 1 Screw Cap Recommended Cable, 5-9 conductor (Wiegand or RS232), 22 AWG shielded (pigtail) Linear DC Power supply Metal or plastic junction box Security Tool (for anti-tamper screw) HID 04-0001-03 1 asseMBly and disasseMBly MontaJe y desMontaJe Montage et dMontage MontageM e desMontageM zusaMMenBau und zeRle-
gung Montaggio e sMontaggio 2 wiRing CaBleado CBlage Fiao VeRdRahtung CaBlaggio Weather Protector ATTENTION Observe precautions for handling ELECTROSTATIC SENSITIVE DEVICES Term Clock-in-Data (ABA) Wiegand P1 P2 P3 P4 P5 P6 P7 P8 Green LED (GRN) Red LED Data Clock Buzzer Input Do not connect (NC) Do not connect (NC) RXD Ground (GRD) Power (PWR) Green LED (GRN) Red LED D1 D0 Buzzer Input RS232 Green LED (GRN)** Green LED (GRN)** Green LED (GRN)**
Red LED**
Do not connect (NC) TXA TXD TXB Do not connect (NC) RXA RXB Ground (GRD) Power (PWR) Red LED**
TRX TRX Do not connect (NC) Do not connect (NC) Ground (GRD) Power (PWR) Ground (GRD) Power (PWR) Ground (GRD) Power (PWR) Red LED**
RS485 RS422
** LED input only valid in read-only applications. CAUTION: 5 VDC is minimum voltage at reader connector pins. Tamper contact (optional): Rating 1A 30 VDC. 3 poweR & testing enCendido y pRueBa aliMentation et test FoRa e teste stRoMVeRsoRgung und testen aCCensione e pRoVa Turn on power Encienda la unidad Mettez sous tension Ligue a energia Einschalten Accendere Test card Pruebe la tarjeta Testez la carte Teste o carto Karte testen Provare la tessera S10 SK10 SP10 SPK10 4 Mounting MontaJe pRpaRation MontageM Montage asseMBlaggio Adhere Sticker Remove Sticker Backing CAUTION: Ensure reader is correctly mounted prior to adhering lense and cap cover. 5 install ReadeR to BaCkplate instalaR leCtoR en la plaCa posteRioR installez le leCteuR suR la plaque aRRiRe instale o leitoR na plaCa posteRioR leseR an deR RCkplatte anBRingen installazione del lettoRe sulla piastRa Junction box not included. Caja para conexiones no incluida. Botier de jonction non inclus. Caixa de juno no includa. Anschlusskasten nicht mit inbegriffen. Scatola di raccordo non inclusa. RegulatoRy ul These proximity readers are intended to be powered from a limited power source output of a previously certified power supply. These readers are intended to be used with listed (UL294) control equipment. Only the Wiegand communication protocol has been investigated by UL. FCC / Canada Radio CeRtiFiCation These devices comply with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Le fonctionnement est soumis aux deux conditions suivantes : (1) Ce dispositif ne peut pas causer de perturbations nuisibles et (2) ce dispositif doit accepter toute perturbation quelconque quil reoit, y compris des perturbations susceptibles de provoquer un fonctionnement indsirable. Les changements ou modifications nayant pas t expressment approuvs par la partie responsable de la conformit peuvent faire perdre lutilisateur lautorisation de faire fonctionner le matriel. This Category II radiocommunication device complies with Industry Canada Standard RSS-310. Ce dispositif de radiocommunication de catgorie II respecte la norme CNR-310 dIndustrie Canada. The Carrier Frequencies and output power are as follows :
803xD, 810xD 13.56MHz
-6.5dBuV/m @ 30m 125kHz
<-4dBuv/m @300m 810xD Ce MaRking HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC. HID Global dclare par la prsente que ces lecteurs proximit sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/EC. A HID Global, por meio deste, declara que estes leitores de proximidade esto em conformidade com as exigncias essenciais e outras condies da diretiva 1999/5/EC. HID Global besttigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfllen. HID Global dichiara che i lettori di prossimit sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC. Japan MiC MIC taiwan dgt/nCC According to "Administrative Regulations on Low Power Radio Waves Radiated Devices" Without permission granted by the DGT, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices. HID Global Corporation Americas 9292 Jeronimo Road Irvine, California 92618-1905 USA Tel. 1-800-237-7769 Fax: (949) 598-1690 Email: tech@hidglobal.com Europe, Middle East and Africa HID Corporation, Ltd. (Haverhill, UK) Tel. +44 (0) 1440 711822 Email: eusupport@hidglobal.com Asia-Pacific HID Asia Pacific Ltd. (Hong Kong) Tel. (852) 3160 9802 Fax: (852) 3160 4809 Email: asiasupport@hidglobal.com www.hidcorp.com 8030-901 Rev A.2 Patent Pending Check reader label for current regulatory approvals. 2008 HID Global Corporation. All rights reserved. installation instalacin installation instalao installation installazione