identiFUEL Nozzle Unit Gen 3 Installation Guide (Model N FNU900) 2804 WEEE Directive RoHS Directive European Union Compliance Conformite Community) Europenne
(European Regulatory Conformance Mark Australia
(RCM) Federal Communications Commission FCC ID: SL6-NUC600 IECEx ATEX This equipment model number FNU900 is certified intrinsically safe for operation in Zone 0 for the following environments For gas environments:
II 1G Ex ia IIB T4 Gb (Ta = -25C to
+60C) For Mines susceptible to firedamp:
I M1 Ex ia I Ma (Ta = -25C to +60C) 2 Contents 1. Safety Instructions ................................................................................................................. 4 2. Training ..................................................................................................................................... 4 Inspection .................................................................................................................................. 4 Label ......................................................................................................................................... 5 Maintenance .............................................................................................................................. 5 Environmental conditions .......................................................................................................... 6 Installation ................................................................................................................................. 6 Operation .................................................................................................................................. 6 identiFUEL Nozzle Unit ...................................................................................................... 7 Universal Low Frequency RFID Readers & Transmitter to Fit on Fueling Nozzles ..................... 7 Key Technology Highlights ........................................................................................................ 7 How does it work? ..................................................................................................................... 8 Specifications......................................................................................................................... 9 Bracket Options ....................................................................................................................10 Installations Instructions ........................................................................................................11 4. 5. Part List ....................................................................................................................................11 Instruction.................................................................................................................................11 3. 6. FNU900 Low frequency Reader & Transmitter Regulatory....................................................12 Regulatory Information .............................................................................................................12 3 1. Safety Instructions Read the safety instructions before installation. Make sure you understand the safety instructions before installation. Electrical installations in hazardous areas possess features specially designed to render them suitable for operations in such atmospheres. It is essential for reasons of safety in those areas that, throughout the life of such installations, the integrity of those special features is preserved; they therefore require initial inspection and either a) regular periodic inspections thereafter, or b) continuous supervision by skilled personnel in accordance with this standard and, when necessary, maintenance. Training The inspection and maintenance of installations shall be carried out only by experienced personnel, whose training has included instruction on the various types of protection and installation practices, the relevant rules and regulations and on the general principles of area classification. Appropriate continuing education or training shall be undertaken by personnel on a regular basis. Skilled personnel must be provided with sufficient training to enable familiarity with the installation which they attend. This training shall include any plant, apparatus, operational or environmental conditions which relate to their understanding of the needs of the explosion protection of apparatus. Where any alterations or changes to the process or installation are affected this information shall be provided to the skilled personnel in a manner which supports their function as part of the continuous supervision process. Inspection Before the apparatus is brought into service, it shall be given an initial inspection. To ensure that the installations are maintained in a satisfactory condition for continued use within a hazardous area, either a) regular periodic inspections, or b) continuous supervision by skilled personnel, and, where necessary, maintenance shall be carried out. If the apparatus is dismantled during an inspection, precautions shall be taken during reassembly to ensure that the integrity of the type of protection is not impaired. Typical inspection schedule:
Apparatus is appropriate to area classification as defined by the label Apparatus temperature class is correct Apparatus category and gas/dust class is correct IP grade of apparatus is appropriate to conductivity of dust Apparatus circuit identification is available Enclosure, glasses and glass to metal sealing gaskets and/or compounds are satisfactory There are no visible unauthorized modifications Bolts, cable entry devices and blanking elements are of the correct type and are complete and Apparatus is adequately protected against corrosion, weather, vibration and other adverse tight conditions No undue accumulation of dust and dirt Apparatus installed is that specified in the documentation 4 Label The label for the apparatus can be found on the underside of the device and contains all applicable information regarding the safety certifications of the device as outlined below:
Label Information The FNU900 nozzle unit has the following label affixed to the unit with the following information available. Maintenance The general condition of all apparatus shall be noted, and appropriate remedial measures shall be taken where necessary. Care shall be taken, however, to maintain the integrity of the type of protection provided for the apparatus; this may require consultation with the manufacturer. Replacement parts shall be in accordance with the manufacturers safety documentation. Alterations to apparatus shall not be carried out without appropriate authorization where they adversely affect the safety of the apparatus as stated in the safety documentation. 5 Environmental conditions Electrical apparatus in a hazardous area can be adversely affected by the environmental conditions in which it is used. Some of the key elements to consider are corrosion, ambient temperature, ultraviolet radiation, ingress of water, accumulation of dust or sand, mechanical effects and chemical attack. Installation Maintenance work may be carried out on energized apparatus subject to the conditions detailed below. Disconnection of, and removal or replacement of, items of electrical apparatus and Adjustment of any controls necessary for the calibration of the electrical apparatus or cabling. system. Removal and replacement of any plug-in components or assemblies. Use of any test instruments specified in the relevant documentation. Where test instruments are not specified in the relevant documentation, only those instruments which do not affect the intrinsic safety of the circuit under test may be used. Any other maintenance activity specifically permitted by the relevant documentation. The person carrying out any of the functions described above shall ensure that the intrinsically safe system or self-contained intrinsically safe apparatus meets the requirements of the relevant documentation after completion of any of those functions. Operation The operator will ensure that:
The unit is maintained and operated, in accordance with the manufacturers instructions and in such a way as to minimize the risks of an explosion. The vehicles ignition is switched off during the insertion and operation of the unit. There are no risks in the explosive zone that could be a potential risk for explosion. 6 2. Universal Low Frequency RFID Readers & Transmitter to Fit on Fueling Nozzles identiFUEL Nozzle Unit Reads vehicle tag and identifies vehicle to the Fuel Management System Automatic activation and standby mode via Tilt Switch Supports a range of standard filling nozzles The HID Global identiFUEL Fueling Nozzle Unit is a universal, intrinsically safe RFID reader, used for Fueling Management Systems (FMS). The Fueling Nozzle Unit can fit onto a wide variety of standard fuel filling nozzles. The unit turns a filling nozzle into an RFID reader that is automatically activated when the nozzle is moved. The Fueling Nozzle Unit works in combination with identiFUEL Vehicle Tags and Wireless Controllers as an RFID front-end for Fuel Management Systems. As soon as the Fueling Nozzle Unit detects a corresponding vehicle tag, the tags unique ID and required fuel information is sent via an encrypted channel to the corresponding identiFUEL Wireless Controller. The controller communicates to the FMS software, which decides if and how much fuel to dispense. Once the nozzle is removed from the vehicle, and the vehicle tag can no longer be read, the Fueling Nozzle Unit notifies the FMS to stop the fuel dispersion. The identiFUEL Fueling Nozzle Unit includes a dual-color LED that indicates whether the unit is operational, and a tag was successfully read. The rugged housing makes the Fueling Nozzle Unit resistant to typical fueling environments and rainwater. Key Technology Highlights Lighter smaller compact universal design Simple installation on various existing nozzles Fully encapsulated rugged & antistatic design ATEX / IECEx compliant Multi-year battery life Over the air firmware upgradeability Completely wireless operation RFID auto-tune to compensate for environmental variance (amount of metal) Heartbeat packet (to check in with system when not in use for long periods of time) Anti-tamper feature (attempt to remove unit is reported to system) Real time battery voltage reading Drop and impact detection Pitch and roll angular limitation for control of valid reading (configurable option) 7 1) The nozzle unit fitted to the filling nozzle reads the 125 kHz passive RFID vehicle tag when the nozzle is inserted into the fuel filler pipe, unit remains asleep until moved at which point it searches for a tag. 2) The nozzle unit then sends the tag info along with unit info every 2.2 seconds (ID, status, etc.) over a 433.92 MHz encrypted proprietary RF data link to the Wireless Controller. 3) If the frontend validation passes, the Wireless Controller sends authorization information and a Nozzle In condition, to the Fuel Management System (FMS) which is then responsible for checking whether the vehicle is valid or not according to predefined business rules. It then interacts with the dispensing systems to allow fueling to start. 4) If the nozzle is removed, the unit will not be able to read the vehicle tag anymore and send the appropriate information to the Wireless Controller. 5) The Wireless Controller interprets this as a Nozzle Out condition and sends a message to the FMS. The FMS will then be able to stop fuel dispersion, complete the fueling process and record a completed transaction. How does it work?
8 3. Specifications Electronic Base Model Number FNU900 Transmitter Frequency to Wireless Controller 433.92 MHz RFID Reader (scanner) to Operating Freq. range to Vehicle 121-129kHz Max. Distance to Wireless Controller 328 ft. (100 m) Modulation Data rate Duty Cycle OOK 16.7 kbps 50%
Mode of operation Simplex Max RF output power 10 dBm Data Format EM4582/HitagS - Bi-Phase/Manchester (modulation) Power Supply 2 x 2.5 Ah Lithium Thionyl Chloride Batteries Power Supply Lifetime
~3 years battery life @ 200 minutes per day operation *
Mounting Method Screws (4 Screws) Fits nozzle types Elaflex, SL1 (ER 242.1T), Elaflex, SL1 (ER 242.1) Elaflex, SL1 (ER 242.2) Elaflex, SL2 (Vapour Recovery) Elaflex, SL2 (ER042.1) Elaflex, ZVA Adblue HV Elaflex, ZVA Adblue LV OPW, OPW11 OPW, OPW7H OPW, Avance Gas + Vapour Recovery OPW, Avance, Diesel OPW, 12VW Husky, 1A Husky, VIII Glass filled Nylon (PA6) Housing Material Colour Water Black IP66 Withstands Exposure to Fuel B, mineral oil, petroleum, salt mist, vegetable oil Environmental Test Conditions 68 F (20 C), 100 h 0 to 95% relative humidity at +104 F (+40 C) non-condensing Humidity Drop Test Storage Operating 1 m (3.28 ft) drop (in packaging)
-40 to +176 F (-40 to +80 C)
-13 to +140 F (-25 to +60 C) 9 Certifications FCC, CE, RCM, ATEX, IECEx User Interface Bi-colour indication LED Quantity Per Box Warranty 1 pc. 2 years 4. Bracket Options
* Depends on the operational temperatures and number of fueling operations per day. Nozzle Range Elaflex ZVASL1 Elaflex ZVASL1 Elaflex ZVASL1 Elaflex ZVASL1 Elaflex ZVASL1 Elaflex ZVASL1 Nozzle P/N Spout Diameter Rotatable Bracket P/N Static Bracket P/N ER242.1 ER242.2 ER242.4 ER242.7 24.0 mm 24.0 mm 24.0 mm 24.0 mm FNU015-0-0-NN-00 FNU020-0-0-NN-00 FNU015-0-0-NN-00 FNU020-0-0-NN-00 FNU015-0-0-NN-00 FNU020-0-0-NN-00 FNU015-0-0-NN-00 FNU020-0-0-NN-00 ER242.1T 24.0 mm FNU015-0-0-NN-00 FNU020-0-0-NN-00 ER424.1TMV 24.0 mm FNU015-0-0-NN-00 FNU020-0-0-NN-00 Elaflex ZVA SL2 w/o drip stop ER042.1TMV 24.0 mm FNU015-0-0-NN-00 FNU020-0-0-NN-00 Elaflex ZVA SL2 w/o drip stop ER042.1 24.0 mm FNU015-0-0-NN-00 FNU020-0-0-NN-00 Elaflex ZVA SL2 w/o drip stop ER042.1U 24.0 mm FNU015-0-0-NN-00 FNU020-0-0-NN-00 Elaflex ZVA SL2 w/o drip stop ER042.7 24.0 mm FNU015-0-0-NN-00 FNU020-0-0-NN-00 Elaflex ZVA SL2 w/o drip stop ER042.7U 24.0 mm FNU015-0-0-NN-00 FNU020-0-0-NN-00 Elaflex ZVA25 Elaflex ZVA25 Elaflex ZVA SL2 VR Elaflex ZVA SL2 VR Elaflex ZVA AdBlue Elaflex ZVA AdBlue ER381 ER381.1 Type 1 Type 2 HV LV 30.7 mm 30.7 mm 30.0 mm 30.0 mm 30.0 mm 30.0 mm FNU011-0-0-NN-00 FNU017-0-0-NN-00 FNU011-0-0-NN-00 FNU017-0-0-NN-00 FNU013-0-0-NN-00 FNU018-0-0-NN-00 FNU013-0-0-NN-00 FNU018-0-0-NN-00 FNU013-0-0-NN-00 FNU018-0-0-NN-00 FNU013-0-0-NN-00 FNU018-0-0-NN-00 Elaflex SL2 with drip stop ER042.1TMV 30.4 mm FNU012-0-0-NN-00 Elaflex SL2 with drip stop ER042.1 30.4 mm FNU012-0-0-NN-00 Elaflex SL2 with drip stop ER042.1U 30.4 mm FNU012-0-0-NN-00 Elaflex SL2 with drip stop ER042.7 30.4 mm FNU012-0-0-NN-00 Elaflex SL2 with drip stop ER042.7U 30.4 mm FNU012-0-0-NN-00 OPW Avance OPW Avance OPW11 OPW11 Husky VR
11A 11B 34i 30.4 mm 30.4 mm 20.5 mm 20.5 mm 38.0 mm FNU012-0-0-NN-00 FNU012-0-0-NN-00 FNU014-0-0-NN-00 FNU021-0-0-NN-00 FNU014-0-0-NN-00 FNU021-0-0-NN-00 N/A FNU022-0-0-NN-00 10 N/A N/A N/A N/A N/A N/A N/A 5. Installations Instructions Part List A. Static Bracket (Available in various sizes depending on the nozzle used) B. Base Unit C. 2x M5 Screws E. Front Cover F. 4x M3 Screws D. Backing plate set (2 pieces) G. Top Cover (with magnet for activation) H. 4x M3 Screws (short) Instruction Place the static bracket (A) on the nozzle, preferably as far back as possible while still allowing the backing plate (D) to be fitted behind the static bracket. The static bracket has two screws which can be removed to fit onto the nozzle spout. Place the base unit (B) onto the fitted static bracket as well as the backing plate set (D). Use the M5 Screws (C) to fit the components together. Once the parts are fitted, place on the front cover (E) and fit the M3 screws (F). Now place the top cover (G) on to the base and fit the remaining screws (H). 11 6. FNU900 Low frequency Reader & Transmitter Regulatory Regulatory Information US- FCC Warning Statement FCC ID:SL6-NUC600 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Canada- ISED Warning statement IC :26825-NUC600 This device contains licence-exempt transmitter(s)/receiver(s) that comply withInnovation, Science and Economic DevelopmentCanadas licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. Lappareil ne doit pas produire de brouillage;
2. Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionne ment. IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Cet quipement est conforme aux limites dexposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20cm de distance entre la source de rayonnement et votre corps. The transmitter module may not be co-located with any other transmitter or antenna. Le module metteur peut ne pas tre complant avec un autre metteur ou antenne. CAN ICES-003(B)/NMB-003(B) 12 Australia/ New Zealand Compliance This product conforms to Australia and New Zealand Radio Requirements. European Union Compliance Conformite Europenne (European Community) The full text of the EU declaration of conformity is available at the following internet address:
www.hidglobal/certifications This product operates in the following frequencies:
432-435 MHz band with an RF output power less than 10dBm e.i.r.p 13 Czech Spolenost HID Global tmto prohlauje, e toto radiov zazen, slo modelu FNU900, odpovd poadavkm smrnice 2014/53/EU. pln text EU Prohlen o shod je k dispozici na nsledujc internetov adrese:
www.hidglobal/certifications Tento vrobek pouv nsledujc frekvence:
- frekvenn psmo 432-435 MHz, piem vstupn RF vkon je ni ne 10 dBm EIRP Danish HID Global erklrer hermed, at dette radioudstyr modelnummer FNU900 er i overensstemmelse med direktiv 2014/53/EU. Den fulde tekst i EU-
overensstemmelseser-
klringen kan lses her:
www.hidglobal/certifications Dette produkt fungerer ved flgende frekvenser:
432-435 MHz-bnd med en RF-udgangseffekt p mindre end 10 dBm e.i.r.p. Estonian Finnish Kesolevaga kinnitab HID Global, et see raadioseadmestik mudelinumbriga FNU900 on vastavuses direktiiviga 2014/53/EL. Kogu EL-i vastavusdeklaratsiooni tekst on saadaval jrgmisel internetiaadressil:
www.hidglobal/certifications See toode ttab jrgmistel sagedustel. 432-435 MHz ribalaiusel raadiosagedusliku vljundvimsusega vhem kui 10 dBm e.i.r.p. HID Global vakuuttaa tten, ett tm radiolaite, mallinumero FNU900, vastaa direktiivi 2014/53/EU. EU-
vaatimustenmukaisuus-
vakuutuksen koko teksti on saatavissa seuraavasta Internet-osoitteesta:
www.hidglobal/certiifcation s Tm tuote toimii seuraavilla taajuuksilla:
432-2,435 MHz:n kaista, RF-lhtteho alle 10 dBm EIRP German Greek Hiermit erklrt HID Global, dass dieses Funkgertmodell Nr. FNU900 der Richtlinie 2014/53/EU entspricht. Der vollstndige Text der EU-
Konformittserklrung steht unter der folgenden Internetadresse zur Verfgung:
www.hidglobal/certifications Dieses Produkt arbeitet mit den folgenden Frequenzen:
432-435-MHz-Band mit einer HF-Ausgangsleistung von weniger als 10 dBm EIRP Dutch Hierbij verklaart HID Global dat deze radioapparatuur modelnummer FNU900 in overeenstemming is met Richtlijn 2014/53/EU. De volledige tekst van de Europese conformiteitsverklaring is te vinden op de website:
www.hidglobal/certifications Dit product werkt op de volgende frequenties:
432-435 MHz-band met een RF-uitgangsvermogen van minder dan 10 dBm e.i.r.p.
, HID Global M FNU900 O 2014/53/E.
www.hidglobal/certifications
432-435 MHz
(RF) 10 dBm e.i.r.p. (
) Maltese Hawnhekk, HID Global tiddikjara li dan it-Tagmir tar-
Radju bin- numru tal-mudell FNU900 huwa konformi mad-
Direttiva 2014/53/UE. It-test si tad- dikjarazzjoni ta konformit tal- UE hu disponibbli fdan l- indirizz fuq l-Internet:
www.hidglobal/certifications Dan il-prodott jopera fil-
frekwenzi li ejjin:
432-435 MHz band b'RF output power ta' inqas minn
+10 d Bm e.i.r.p. 14 French Croatian Hungarian Par la prsente, HID Global dclare que cet quipement radio Modle FNU900 est conforme la directive 2014/53/UE. Le texte intgral de la dclaration de conformit de l'UE est disponible sur le site Internet:
www.hidglobal/certification s Ce produit fonctionne aux frquences suivantes:
dans la bande de 432-435 MHz avec une puissance de sortie RF infrieure 10 dBm PIRE Ovime tvrtka HID Global izjavljuje da je ova radijska oprema model FNU900 u skladu s Direktivom 2014/53/EU. Cjelokupan tekst europske izjave o sukladnosti dostupan je na sljedeoj internetskoj stranici:
www.hidglobal/certifications Ovaj proizvod radi pri sljedeim frekvencijama:
pri frekvenciji od 432-435 MHz s izlaznom RF snagom manjom od 10 dBm e.i.r.p Lithuanian Latvian iuo deklaruoja, kad is radijo rangos modeHID Global lis, kurio numeris FNU900, atitinka Direktyv 2014/53/EB. Vis ES atitikties deklaracijos tekst galite rasti iuo interneto adresu:
www.hidglobal/certifications is gaminys veikia tokiais daniais:
432-435 MHz danio diapazonas, RD ivesties galia yra maesn nei 10 dBm EIRP Ar o uzmums HID Global apliecina, ka radioiekrta, modea numurs FNU900, atbilst Direktvas 2014/53/ES prasbm. Pilnu ES atbilstbas deklarcijas tekstu var skatt vietn www.hidglobal/certifications is izstrdjums darbojas ar dm frekvencm:
432-435 MHz josla;
radiofrekvences izvades jauda ir mazka par 10 dBm
(ekvivalent izotropiski izstarot jauda). Spolonos HID Global tmto vyhlasuje, e toto rdiov zariadenie, model FNU900, je v slade so smernicou 2014/53/E. pln znenie vyhlsenia o zhode so smernicami E je k dispozcii na strnke:
www.hidglobal/certifications Toto zariadenie pracuje pri nasledujcich frekvencich:
432-435 MHz psmo s RF vstupnm vkonom nim ako 10 dBm EIRP Portuguese Por este meio, a HID Global declara que este modelo de equipamento de rdio, nmero FNU900, est em conformidade com a Diretiva 2014/53/UE. O texto completo da declarao de conformidade da UE est disponvel no seguinte endereo da Internet:
www.hidglobal/certification s Este produto opera nas frequncias seguintes:
432-435 MHz com uma potncia de sada de RF inferior a 10 dBm e.i.r.p. A HID Global ezton nyilatkozza, hogy ez az FNU900 tpusszm rdiberendezs megfelel a 2014/53/EU irnyelvnek. Az EU megfelelsgi nyilatkozat teljes szvege elrhet a kvetkez internetes cmen:
www.hidglobal/certifications A termk a kvetkez frekvencikon zemel:
432-435 MHz-es sv, mely esetben RF kimeneti teljestmnye kevesebb, mint 10 dBm EIRP Polish Firma HID Global deklaruje niniejszym, e to urzdzenie radiowe, model numer FNU900, spenia wymogi okrelone w Dyrektywie 2014/53/UE. Peny tekst deklaracji zgodnoci UE jest dostpny pod nastpujcym adresem internetowym:
www.hidglobal/certifications Ten produkt dziaa na nastpujcych czstotliwociach:
w pamie 432-435 MHz z rwnowan moc wyjciow RF wypromieniowan izotropowo (EIRP) mniejsz ni 10 dBm Spanish Por la presente, HID Global declara que este equipo de radio, modelo nmero FNU900 cumple la Directiva 2014/53/EU. El texto completo de la Declaracin de Conformidad CE est disponible en la siguiente direccin de internet: www.hid global/certifications Este producto opera en las siguientes frecuencias:
Banda de frecuencia de 432, 435 MHz con una potencia de salida de RF (PIRE) de menos de 10 dBm Swedish Hrmed intygar HID Global att denna radioutrustning modell nummer FNU900 verensstmmer med direktiv 2014/53/EU. Den fullstndiga texten med intyg om verensstmmelse fr EU finns p fljande internetadress:
www.hidglobal/certifications Den hr produkten fungerar p fljande frekvenser:
432-435 MHz-band med en RF-uteffekt p mindre n 10 dBm e.i.r.p. Italian Con il presente documento, HID Global dichiara che la presente apparecchiatura radio modello FNU900 conforme alla direttiva 2014/53/UE. Il testo completo della dichiarazione UE di conformit disponibile su Internet al seguente indirizzo:
www.hidglobal/certification s Questo prodotto funziona alle seguenti frequenze:
Banda a 432-435 MHz con potenza di uscita RF inferiore a 10 dBm EIRP Druba HID Global izjavlja, da je ta radijska oprema, tevilka modela FNU900, v skladu z Direktivo 2014/53/EU. Celotno besedilo izjave EU o skladnosti je na voljo na naslednjem spletnem naslovu:
www.hidglobal/certificati ons Ta izdelek deluje pri naslednjih frekvencah:
432,435 MHz z izhodno mojo RF manj kot 10 dBm e.i.m.o.
(EIRP) Slovenian Slovak hidglobal.com/solutions/fueling-automation 2021 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, HID Global, the HID Blue Brick logo, the Chain Design, identiFUEL are trademarks or registered trademarks of HID Global or its licensor(s)/supplier(s) in the US and other countries and may not be used without permission. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. 2021-01-12 placeholder 15