User Man Sensing & Internet of Things www.sensing.honeywell.com About the Product The IQ%
Product Code PM 2.5 Formaldehyde TV OC CO Temp Humidity IQ%
Time Alarm App HAQSPA_R impact of air environment elements on cognitive ability. Product Measurement: 80 x 80 x 22(mm) Weight: 156g USB Port: Micro USB Materials: Aluminum alloy casing Screen:
OLED Touch screen Input Voltage: 5V Input Current: 1A Battery: 18,650 lithium-ion battery Battery Capacity: 2,600mAh Range and Precision Description PM2.5 Detection Range Precision/Resolution 100 ~ 999ug/m3
<100ug/m3 15%
15ug/m3 HCHO
(Formaldehyde) 0 ~2ppm TVOC CO Temperature Humidity IQ%
0.12 ~ 0.99ppm 400 ~ 2,000ppm
-10 ~ 40 0% ~ 100%
0 ~ 100%
0.01ppm(resolution) 0.01ppm(resolution) 1ppm(resolution) 1 5%
1%(resolution) Wireless connection: Wi-Fi IEEE 802.11 b/g/n 2.4GHz Equipment requirements: Supports mobile phones with Android 4.42 or iOS 8.0 or better Note: Supports only iPhone5 and later versions App Download Network Connection Scan the Store and Android Market or search Honeywell IAQ in Apple App Icon and Instructions on Colors About App Functions PM2.5 HCHO TVOC CO 2 IQ%
0 ~ 79ug/m3
< 0.08ppm
< 0.38ppm < 1,000ppm
>60%
80 ~ 199ug/m3
> 200ug/m3
>0.08ppm
>0.38ppm
>1,000ppm <60%
Self-de ned alarm value: Default alarm value is factory setting. For threshold please see explanation above for App icon. The user can def i ne alarm value according to own needs. The equipments indicator light and App on the users mobile phone will display in accordance Alarm clock: 3 alarms can be set for each device while it is connected to the network. If the alarm rings simply touch the screen or press the Home button Note: Air quality of PM2.5 and IQ% are showed through the change of font color accordingly . The activity. Mode and Setting Sleep mode: The screen and indicator light will extinguish during set time durations and the frequency of data collection will reduce to once per hour. Switch the mode using the App if the device is connected to network. Energy-saving mode: The frequency of data collection for the device will reduce to once per hour. Switch the mode using the App if the device is connected to network. nterface Instructions Enter the main interface after activating the device. Press the icon light to switch to main screen; it will show real-time air Flashing icon indicates excess values. value. 92 92 CO2 manual calibration:
Carry the device outdoors, switch to the CO2 icon, and then press and hold the center of the screen for 3 seconds until the phrase being calibrated appears on the screen and the device enters calibration mode. Place the device outdoors for 20 minutes continuously until the phrase being calibrated disappears, which means the device will automatically exit the calibration mode upon completing calibration. CO2 automatic calibration:
Enable: The device will automatically calibrate and exit energy savings mode after continuous operation for 60 days. This calibration will be completed in 28 hours. Device indicator light and color: The devices indicator light shows the current air quality indicator for the detection item Detection Item Green Orange Red PM2.5 0 ~ 79ug/m3 80 ~ 199ug/m3 200ug/m3 Formaldehyde < 0.08ppm TVOC CO 2
< 0.38ppm
< 1,000ppm Temperature
-10 ~ 40 Humidity 0% ~ 100%
> 0.08ppm
> 0.38ppm
> 1,000ppm IQ%
> 60%
< 60%
Packing List Indoor cable x 1 92
; Product Manual x 1; USB Indoor Air Quality (IAQ) Product Manual Note when detecting formaldehyde/TVOC: Due to its packaging, the device will display a higher reading when in use for the first time, which is normal. The device may be placed in a well-ventilated area until the reading drops down to 0.08 ppm before use. The formaldehyde/TVOC sensor is an electrochemical sensor. Due to the effects from its electrochemical properties, detection of formaldehyde/T-
VOC by the electrochemical sensor will be affected by any substance that contains toluene, benzene, alcohol, acetic acid, hydrogen sulfide, carbon monoxide. Please keep the device away from substances such as wine, perfume, cosmetics, pesticides, etc. when in use. The date and time settings of the device can only be updated when connected to the internet. Please keep the device connected to the internet. Do not charge when the temperature falls below zero. The device collects data from incoming air through the built-in fan. It is normal for the device to make low levels of sound. When in use, keep the device away from any strong magnet field which may interfere with the built-in sensor (such as PM2.5 sensor). If the device fails to connect to the internet, the mDNS and DHCP of the router may experience issues. Please check that these two router functions are enabled or reboot the router to reconnect. We recommend that the routers default IP address range be 192.168.X.X. with the gateway as 192.168.1.1. FCC Statements Note: This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. IC Statements This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. this device may not cause interference, and 2. this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorise aux deux conditions suivantes :
1. l'appareil ne doit pas produire de brouillage, et 2. l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas l'intensit ncessaire l'tablissement d'une communication satisfaisante. Attention To better reflect the true air environment, we recommend continuously monitoring the average values on the app. It is recommended that the device be charged for 24 hours continuously the first time you use it, so that it can be initialized. As a protective measure, the powered off device will continue to provide a weak current to the sensor. Even if fully charged, the device will drain the power if it is not used
. for a long period of time and must be recharged before being used again. When charged, the device will have a slightly higher temperature even at a low power level. The temperature of the fully charged device will not be affected even if it remains connected to its power supply. Warranty Under circumstances where the product is in normal use and maintenance, Honeywell provides users with the warranty that this product will have no defects in processing or materials within one (1) year following the date of purchase. Where Honeywell verifies such product experiences any defect or malfunction in any form within the specif i ed warranty period, Honeywell will repair or replace any defective product upon verif i cation. In case of defective products, users may return such product to the distributor where they made the original purchase. This warranty does not cover any defects and malfunction of the product arising from any unauthorized dismantling or reinstallation. This warranty also does not cover any defect or malfunction that results from human factors during the warranty period. Honeywells sole responsibility is to repair or replace the product based on the aforesaid provisions. Honeywell shall not be responsible for any loss or damage of any form, including any accidental or necessary direct or indirect loss as a result of breach of any warranty or any other acts that damage the product. This warranty represents the only explicit guarantee as undertaken by Honeywell with respect to such products. Any implied guarantee, including implied guarantees with respect to product marketability and applicability of specific usage, shall not apply. This warranty only applies to the main unit of the product, and does not cover the package, manuals, consumables, or other components susceptible to damage or consumption. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit di erent from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation d'Industrie Canada, le prsent metteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain RF Exposure After the laboratory measurement, the SAR value (0.0085W/kg for Europe, 0.029W/kg for North American) satisfies the RF exposure requirement To satisfy RF exposure compliance the user should operate the device as the User Manual introduced and the antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Caution H H HAQSPA_R are in Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions Honeywell International Inc. a r. H erve e ri t i y o o e an a are t a o e Inc. wit II w t nt any co it nt HII. HII i ot r o i le or any tec ical r o t ter t ntione t al t eir re ective co i c a e owne ca rovi i nti o i aterial. HII i ot etary i ion conta t article i rotect i t. All rv
. it or written co ent a oco y y or tran ation into ot not allow . er y HII HAQSPA_R| Dec 2018 2018 Honeywell International Inc. Rev: V 3