all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 843.71 KiB | September 11 2020 | |||
1 |
|
Int Photos | Internal Photos | 1.68 MiB | September 11 2020 | |||
1 |
|
Ext Photos | External Photos | 425.44 KiB | September 11 2020 | |||
1 |
|
FCC ID Label | ID Label/Location Info | 847.88 KiB | September 11 2020 | |||
1 |
|
Attestation Letter | Attestation Statements | 22.30 KiB | September 11 2020 | |||
1 | Block Diagram | Block Diagram | September 11 2020 | confidential | ||||
1 |
|
Confidentiality Letter | Cover Letter(s) | 69.79 KiB | September 11 2020 | |||
1 |
|
Frequency Justification Letter | Cover Letter(s) | 60.55 KiB | September 11 2020 | |||
1 | Opeation Description | Operational Description | September 11 2020 | confidential | ||||
1 |
|
Power of Attorney Letter | Cover Letter(s) | 20.29 KiB | September 11 2020 | |||
1 | Parts List | Parts List/Tune Up Info | September 11 2020 | confidential | ||||
1 |
|
RF Exposure | RF Exposure Info | 65.97 KiB | September 11 2020 | |||
1 | Schematics | Schematics | September 11 2020 | confidential | ||||
1 |
|
Test Report | Test Report | 915.77 KiB | September 11 2020 | |||
1 | Tune up Procdure | Parts List/Tune Up Info | September 11 2020 | confidential |
1 | User Manual | Users Manual | 843.71 KiB | September 11 2020 |
Preface Thanks for your favor in our product. To derive optimum performance from the product, please read this manual carefully before use. This manual is applicable to the following product:
CHU-P1BA01 DMR Trunking Lite Channel Unit Documentation Conventions For your better understanding of this manual, please read the following conventions first. Instructional Icons Caution: Indicates situations that could cause damage to your product or bodily injury. Note: Indicates tips that can help you make better use of your product.
*: Indicates functions available in later version. Key Operation Short Press: To press a key and release it immediately. Long Press: To press a key and hold it for the preset time (two seconds by default). Hold: To press a key and keep holding it down. Term Explanation Duplexer is a device that allows bi-directional communication. Its role is to isolate the TX signal from the RX signal to ensure that the transmitter and receiver can work normally. It consists of two groups of band-stop filters with different frequencies, to prevent it from transmitting the signals to the receiver. Feed Line is the cable or transmission line that connects the antenna with the radio transmitter or Voltage Standing Wave Ratio (VSWR) is a value that measures how well a load is Squelch is a circuit function that acts to suppress the audio output of a receiver in the absence of a receiver. impedance-matched to a source. sufficiently strong desired input signal. Copyright Information Hytera is the trademark or registered trademark of Hytera Communications Corporation Limited (the Company) in PRC and/or other countries or areas. The Company retains the ownership of its trademarks and product names. All other trademarks and/or product names that may be used in this manual are properties of their respective owners. The product described in this manual may include the Companys computer programs stored in memory or other media. Laws in PRC and/or other countries or areas protect the exclusive rights of the Company with respect to its computer programs. The purchase of this product shall not be deemed to grant, either directly or by implication, any rights to the purchaser regarding the Companys computer programs. Any of the Companys computer programs may not be copied, modified, distributed, decompiled, or reverse-engineered in any manner without the prior written consent of the Company. The AMBE+2TM voice coding technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trade secrets of Digital Voice Systems, Inc. This voice coding technology is licensed solely for use within this product. The user of this technology is explicitly prohibited from attempting to decompile, reverse engineer, or disassemble the Object Code or in any other way convert the Object Code into a human-readable format. Disclaimer The Company endeavors to achieve the accuracy and completeness of this manual, but no warranty of accuracy or reliability is given. All the specifications and designs are subject to change without notice due to continuous technology development. No part of this manual may be copied, modified, translated, or distributed in any manner without the express written permission of us. We do not guarantee, for any particular purpose, the accuracy, validity, timeliness, legitimacy or completeness of the Third Party products and contents involved in this manual. If you have any suggestions or would like to learn more details, please visit our website at:
http://www.hytera.com. RF Radiation Information This product must be restricted to operations in an Occupational/Controlled RF exposure Environments. Users must be fully aware of the hazards of the exposure and able to exercise control over their RF exposure to qualify for the higher exposure limits. RF Radiation Profile Radio Frequency (RF) is a frequency of electromagnetic radiation in the range at which radio signals are transmitted. RF technology is widely used in communication, medicine, food processing and other fields. It may generate radiation during use. RF Radiation Safety In order to ensure user health, experts from relevant industries including science, engineering, medicine and health work with international organizations to develop standards for safe exposure to RF radiation. These standards consist of:
United States Federal Communications Commission, Code of Federal Regulations; 47CFR part 2 American National Standards Institute (ANSI)/Institute of Electrical and Electronic Engineers (IEEE) sub-part J;
C95. 1-1992;
Institute of Electrical and Electronic Engineers (IEEE) C95.1-1999;
International Commission on Non-Ionizing Radiation Protection (ICNIRP) 1998;
FCC/IC Regulations Federal Communication Commission (FCC) requires that all radio communication products should meet the requirements set forth in the above standards before they can be marketed in the U.S, and the manufacturer shall post a RF label on the product to inform users of operational instructions, so as to enhance their occupational health against exposure to RF energy. Operational Instructions and Training Guidelines To ensure optimal performance and compliance with the occupational/controlled environment RF energy exposure limits in the above standards and guidelines, users should transmit not more than 50% of the time and always adhere to the following procedures:
Antenna gain must not exceed 9.6dBi. The antenna must be installed complying with the requirements of manufacturer or supplier, and it must be at least 2meters away from human body. Note: Use the accessories specified by Hytera only. If not, Hytera shall not be liable for any losses or damages arising out of use of unauthorized accessories. FCC Radiation Exposure This equipment complies with FCC radiation exposure limits set forth for an controlled environment. This equipment should be installed and operated with minimum distance 200cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Verification of harmful interference by this equipment to radio or television reception can be determined by turning it off and then on. The user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a different circuit to that of the receiver's outlet. Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Note: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This radio complies with IEEE and ICNIRP exposure limits for occupational/controlled RF exposure environment at operating duty factors of up to 50% and is authorized by the FCC for occupational use only. ISEDC Radiation Exposure Statement:
This equipment complies with ISEDC RF radiation exposure limits set forth for an occupational/
controlled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 200cm between the radiator& your body. IC exposition aux radiations:
Cet quipement est conforme avec ISEDC les limites d'exposition aux rayonnements dfinies pour un environnement professionnel/contrl.Cet metteur ne doit pas tre co-localiss ou fonctionner en conjonction avec une autre antenne ou metteur.Cet quipement doit tre install et utilisavec une distance minimale de 200cm entre leradiateur & votre corps. ISEDC Statement This device complies with Innovation, Science and Economic Development Canada Compliance licence-exempt RSS standard (s). Operation is subject to the following two conditions: (1) this device may not cause interference
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, susceptible d'en compromettre le fonctionnement. et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est EU Regulatory Conformance As certified by the qualified laboratory, the product is in compliance with the essential requirements and other relevant provisions of the Directive 2014/53/EU. To satisfy RF exposure requirements, a separation distance of 10.9m or more should be maintained between this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. Please note that the above information is applicable to EU countries, and the functions of Digital repeater including UHF within the band 400-470MHz for this device are restricted to use within all European Union countries(BE, BG, CZ, DK, DE, EE, IE, EL, ES, FR, HR, IT, CY, LV, LT, LU, HU, MT, NL, AT, PL, PT, RO, SI, SK, FI, SE, UK). For more details, please contact the local distributor or responsible part. Contents 1. Items in the Package .............................................................................................................................. 1 2. Product Overview ................................................................................................................................... 2 3. Before Use............................................................................................................................................... 5 4. Status Indication .................................................................................................................................. 10 5. Menu Navigation ................................................................................................................................... 12 6. Basic Operations .................................................................................................................................. 15 7. Alarm Information ................................................................................................................................ 17 8. Troubleshooting ................................................................................................................................... 22 9. Care and Cleaning ................................................................................................................................ 24 10. Optional Accessories ........................................................................................................................ 25 11. General Information ........................................................................................................................... 26 1. Items in the Package Please unpack carefully and check that all items listed below are received. If any item is missing or damaged, please contact your local dealer. Repeater DC Power Cord Fuse Documentation Kit 1 2. Product Overview 2.1 Front Panel No. Part Name No. Part Name 1 2 3 4 5 6 7 8 Accessory Jack 9 Slot 1 RX Indicator Volume Control Knob/Power Indicator 10 Alarm Indicator Operation Status Indicator Programmable Keys *
Analog Mode Indicator LCD Display Slot 2 RX Indicator Slot 2 TX Indicator Channel Up Key Navigation Knob Digital Mode Indicator Channel Down Key Slot 1 TX Indicator Speaker 11 12 13 14 15 16 2 2.2 Rear Panel No. Part Name No. Part Name TX Antenna Connector
(Type-N Accessory Jack Female) Female) 1 2 3 4 5 Optional Interface 1 DC Power Inlet RX/Duplex Antenna Connector (Type-N Ethernet Port *
Optional Interface 2 Ground screw Monitor/Tuning Interface
2.3 Programmable Keys *
For enhanced convenience, you can request your dealer to program the keys P1, P2, P3 and P4 as shortcuts to the functions. Please contact your dealer for more information. 6 7 8 9
3 No. Part Name Part Name 1 2 3 Baseband Module Front Panel PA Module No. 4 5
Exciter Module Receiver Module
2.4 Internal Parts 4 The repeater is used to transfer and amplify the radio signal, increasing the coverage and call distance. Proper installation can ensure optimum performance and reliability of this product. Thus, please install it 3. Before Use properly before use. 3.1 Application Single repeater application Target industries: neighborhood coverage, building blind spot elimination, and dispatch. Application requirements: small-scale coverage, dispatch, and building blind spot elimination. Multiple repeater application Target industries: public safety, transportation, and forestry fire fighting. Application requirements: industries or groups with network demand and large-scale use of radios. When operating alone, the repeater can be used for data transferring between radios or between the radio and the repeater. It can also work with our DMR digital simulcast system, analog simulcast system and lite digital trunking system. Please refer to our corresponding system product documents for details. 3.2 Installation 3.2.1 Installation Requirements Installation Environment
+60 and relative humidity of 95%. Installation Location Installation Tools spanner. The repeater must be installed in a dry and well-ventilated place with ambient temperature of -30 to The repeater can be installed in a rack, bracket and cabinet or on a desk. Tools required for installing the repeater include a crosshead screwdriver, a T-10 torx screwdriver and a Note: Please refer to Safety Information Booklet for more information. 5 3.2.2 Before Installation Voltage Check Product Check panel. Parameter Configuration Please check whether the voltage of DC power or battery meets the repeater specifications (28V15%). Please check whether the repeater works properly by observing the eight LEDs located in the front Having confirmed that the repeater works properly, you can let your dealer configure the parameters for the repeater based on your actual needs (such as Frequency Range, TX Power, etc.), and then you can proceed with on-site installation. 3.2.3 Installation Procedures Follow the steps to install the repeater:
1. Install the repeater at a proper location;
2. Connect accessories such as the antenna, feed line and power cord to the repeater. 3. Ground the repeater through the ground screw located on the rear panel. 3.3 Installing the Duplexer (Optional) If the repeater needs to work with a duplexer, you should implement the following operations before installation. 1. Loosen the three screws on the bracket with a crosshead screwdriver. See the following figure:
2. Install the duplexer onto the bracket. 6 Be sure to observe the specifications of the two antenna interfaces on the duplexer, to determine which one should be connected to the transmitter. The interface connecting the transmitter should be close to PA module to reduce RF loss. See the following figure:
3. Loosen the screws at the back of the top cover, and then pull the top cover backwards to remove it. See the following figure:
4. Loosen the six screws locking the PA heat sink, remove all power, data and RF cables from the PA, and finally remove the PA heat sink. See the following figure:
5. Connect the RF cable. See the following figure:
7 6. Install the duplexer to the repeater. Mount the duplexer properly on the exciter module and receiver module, and then fasten it with the two screws inside the housing and on the side respectively. 7. Attach the PA heat sink and connect all PA power, data and RF cables to it. 8. Close the repeater top cover and the installation is complete. Installation Diagram Duplexer with Front Side Facing Upwards 8 Duplexer with Front Side Facing Downwards 3.4 After-installation Check After installation is completed, power on the product and check whether it works properly by observing the eight LEDs and the LED segment display located in the front panel. 9 You may customize repeater parameters such as TX/RX frequency, TX power and signalling, according to user needs. After configuration of parameters is complete, you may perform site installation. Installation Requirements 1. Environmental Conditions at Intended Installation Site The repeater may be installed in any location suitable for electronic communication equipment, provided that the environmental conditions do not exceed the equipment specifications for temperature, humidity and air quality. Operating Temperature
-30 to +60 Humidity Air Quality This is the temperature measured in close proximity to the repeater. For example, if the repeater is mounted in a cabinet, the temperature within the cabinet is measured. Humidity conditions should not exceed 95% relative humidity @ 50C. For equipment operating in an area which is environmentally controlled and with the repeater rack mounted, the airborne particle level must not exceed 25g/m3. And for equipment operating in an area which is not environmentally controlled and with the repeater cabinet mounted, the airborne particle level must not exceed 90g/m3. Caution: If the repeater is to be installed in an area which is usually dusty, dirty, or does not meet the air quality requirements, then the air used to cool the repeater modules must be treated using appropriate filtering devices. Dust or dirt accumulated on the internal circuit boards and modules is not easily removed, and can cause malfunctions such as overheating and intermittent electrical connections. 2. Equipment Ventilation The PA heatsink is equipped with a cooling fan used to provide forced convection cooling. When planning the installation, observe the following ventilation guidelines:
Customer supplied cabinets must be equipped with ventilation slots or openings for 8 air to enter and exit. If several repeaters are installed in a single cabinet, ensure ventilation openings surrounding each repeater allow for adequate cooling. All cabinets must have at least 10cm of open space between the air vents and any wall or other objects. When multiple cabinets (each equipped with several repeaters) are installed in an enclosed area, ensure appropriate ventilation and consider air conditioning or other climate control equipment, to satisfy the temperature requirements stated above. 3. Equipment Installation Methods The CHU-P1BA01 may be mounted in a rack, bracket or cabinet, and may be placed on your desk. 4. Site Grounding and Lightning Protection Caution: Proper site grounding and lightning protection are vitally important considerations. Failure to provide proper lightning protection may result in permanent damage to the repeater. The ground and lightning protection system is one of the most important considerations when designing a communication site. Proper grounding techniques and lightning protection are closely related, and the general category of site grounding may be divided into the following two sections:
Electrical Ground located at the site. Lightning Ground Ground wires carrying electrical current from circuitry or equipment at the site are included in the category of electrical ground. Examples include the AC and DC power used to source equipment located at the site, and wires or cables connected to alarms or sensors Providing adequate lightning protection is critical to a safe reliable communication site. The repeater is equipped with a ground screw located on the rear panel. This screw is used to connect the repeater to the site grounding. All antenna cables, and AC and DC power cords, should be properly grounded and lightning protected by following the rules and guidelines provided in the above sections. 9 After the repeater has been mechanically installed, electrical connections must be made. Electrical Connections This involves making the following connections:
DC power cord Antenna cables See the rear panel view for the positions of connectors. Power Supply Connections 1. Ground Connection wires to the screw. 2. DC Power Supply or Battery Backup Connection The repeater is equipped with a ground screw located on the rear panel. Connect ground 13 The repeater may be connected to a regulated DC power supply or a backup battery. The DC source or battery backup system is connected to the repeater through the DC power inlet at the rear of the repeater (see rear panel view). Caution: Before you make the connection, ensure the DC power supply or battery backup system is capable of supplying a minimum of 200W, and check if the DC power supply has current limit. Since high current consumption is required for transmitting, improper setting of the current limit may cause transmission failure. Caution: The repeater is to be connected to a battery that is in accordance with applicable electrical regulations for the end use country. If battery power is exhausted, you are recommended to charge the battery with an external charger. Remove the battery from the repeater when charging. RF Antenna Connections TX and RX antennas are connected to two separate connectors (shown in the rear panel view), and there must be adequate isolation of 75 dB UHF or 85 dB VHF between them. If only one antenna through a duplexer is connected, at least 75 dB UHF or 85 dB VHF isolation between the TX and RX antenna ports is required. Caution: Please ensure that all power is switched off before disconnecting the TX antenna. 1. Duplexer Selection The selection of duplexer is critical to system performance. The use of a notch (band reject) duplexer is possible in some systems that are not located at high RF density sites. If the repeater is used in high RF density sites, the use of a pass-notch duplexer is recommended. The duplexer must be able to handle at least 50W continuously. For the best system performance, the insertion loss should be less than 2dB. 14 2. Antenna Selection The selection of antenna is also critical to system performance. The selected antenna must be 50 Ohm impedance and capable of at least 50W. High gain antennas may be used to increase system coverage. Please take note of licensing restrictions when selecting high gain antennas. Some services or regions may have antenna gain or system radiation limitations. The antenna must be connected to the duplexer with a high grade 50 Ohm transmission line (e.g. Andrew HELIAX cables). The line must have connectors to match the connectors on the duplexer and antenna. Caution: It is important that all antenna cables are grounded at the point they enter the building. All aspects of the antenna design must comply with the relevant local regulations. Post-Installation Checklist After the repeater has been mechanically installed and all electrical connections have been made, power may now be applied and the repeater should be checked for proper operation. 1. Applying Power also by LCD prompts. repeater. Before applying power to the repeater, make sure all boards are securely seated in the appropriate connectors on the rear panel and all RF cables are securely connected. Turn on the DC power source to supply power to the repeater. 2. Verifying Proper Operation Operation of the repeater can be indicated by the 8 LEDs located on the front panel and Caution: Some repeater components can become extremely hot during operation. Turn off all power and wait until the repeater is sufficiently cool before touching the 15 4. Status Indication 4.1 LCD Icon These icons may appear on LCD to help you easily identify the repeater status. Icon Name Icon Product Status TX Power Icon Accessory Icon*
Alarm Icon GPS Lock Icon Network Connection Icon Low TX power for the current channel. High TX power for the current channel. An accessory is connected. An alarm message is given. the satellite signals satellite signals. Loss of GPS lock. The GPS signals will not synchronize with GPS locked. The GPS signals will synchronize with the Operation Mode Icon Repeater Mode: The repeater will transfer the communication requests from other radios and systems. Monitor Icon The Monitor feature is enabled. Scramble/Encr ypt Icon The Scrambler/Encrypt feature is enabled. Scan Icon*
Scan is in progress. Speaker Icon*
The speaker is unmuted. Successful network connection. The repeater can transfer data Abnormal network connection. The repeater cannot connect to Network disconnection due to improper connection to the properly. the control center. network cable. 10 4.2 LED Indicator Name LED Indication Product Status Power Indicator Green Normal power-on. Alarm Indicator Red Abnormal operation and the alarm pops up. Operation Status Indicator Green The repeater is operating in Repeater mode. Off The repeater is operating in Base mode. Slot 1 TX Indicator Red The repeater is transmitting on an analog channel or in slot 1. The repeater is receiving on an analog channel Slot 1 RX Indicator Green or in slot 1. Slot 2 TX Indicator Red The repeater is transmitting in slot 2. Slot 2 RX Indicator Green The repeater is receiving in slot 2. Analog Mode Indicator Yellow The repeater is operating in Analog mode. Digital Mode Indicator Blue The repeater is operating in Digital mode. 11 5. Menu Navigation displayed in the repeater via your dealer. The following menu list shows all the menus of the repeater. You can select your needed menus to be To select and confirm the options shown in the menu, press the Menu key to enter the main menu, and then press the Up/Down key to select your needed option, finally press the OK key. This manual only describes the path to the menus when instructing menu operations, for example, to close the speaker, go to Digital Speaker -> Close. The repeater supports menu reset function, that is, if you do not operate the menu for a predefined time period set by the dealer, the repeater will automatically return to the home screen. You can define the reset time or cancel the reset feature via your dealer. For Digital Channel Main Menu Radio Info Channel Info Digital Speaker Exit Radio ID Radio Alias CH Alias Slot 1 Serial Number Radio Model TX Frequency Freq Range Firmware Ver RX Frequency RCDB Ver Bootload Ver Color Code Program Date En Lang Ver Slot 2 Close Exit 12 For Analog Channel Main Menu Radio Info Channel Info Scan Exit Radio ID Radio Alias CH Alias Serial Number Radio Model TX Frequency Freq Range Firmware Ver RX Frequency RCDB Ver Bootload Ver CH Band Program Date En Lang Ver TX CTCSS/CDCSS Scan on Scan off Exit RX CTCSS/CDCSS 13 For Mixed Channel Main Menu Radio Info Channel Info Digital Speaker Exit Radio ID Radio Alias CH Alias TX Frequency Slot 1 Serial Number Radio Model Freq Range Firmware Ver RCDB Ver Bootload Ver Program Date En Lang Ver RX Frequency TX CTCSS/
CDCSS Color Code CH Band RX CTCSS/
CDCSS Slot 2 Close Exit Note: If non En Lang Ver is downloaded in the repeater, the Other Lang Ver menu will be available in the Radio Info menu on the above three channels. 14 6. Basic Operations 6.1 Powering On/Off ON: Turn on the repeater by connecting a DC power supply to it. During power-up process, the Power Indicator glows green and the power-up screen appears. OFF: To turn the repeater off, disconnect it from the DC power supply. 6.2 Adjusting the Volume For analog channel: Rotate the Volume Control knob clockwise to increase the volume or counter-clockwise to decrease the volume. For digital channel and mixed channel: The speaker cannot be unmated, this knob is null. 6.3 Adjust Power Level You can request your dealer to set the TX power to High or Low. High power can extend the repeater coverage, enabling you to communicate with farther radios. On the LCD, High power is indicated by and Low power is indicated by
. 6.4 Backlight*
Activating the backlight can illuminate the LCD and all the front panel keys, so as to facilitate your operation under dim light conditions. Your dealer may set the backlight to operate in any of the following modes:
Timed: Key press, knob operation or receiving/transmitting signals can activate the backlight. If no foregoing event occurs within the specified time period, the backlight will go out automatically. Enable: The backlight remains activated all the time. Note: When an error occurs, the backlight will glow until the alarm disappears. Then it will recover the original operation mode. 6.5 Locking/Unlocking the Repeater You can request your dealer to lock the knob and all keys in the front panel to prevent accidental 15 operation. To unlock, the repeater must be re-programmed by your dealer. 6.6 Changing the Channel You can use the Channel Up or Channel Down key in the front panel to change the channel, and the LCD will display the alias of the current channel. The Channel Up key is for the former channel and the Channel Down key for the latter one. 16 7. Alarm Information The repeater will have real-time detection of its status automatically. If the Alarm feature is enabled by your dealer, the LCD will display an alarm message with the Alarm Indicator on the front panel glowing red when the repeater is operating abnormally. 7.1 Low Forward Power Alarm When the forward power is below the preset value, the Alarm Indicator will glow red and the LCD will display the prompt message below:
Then the repeater may continue or terminate the transmission, subject to the detection result. And you need to take the following measures:
1. Check if the connection between the transmitter and RF adapter cable or antenna/feed line is loose or damaged. If yes, secure or replace the cable or antenna/feed line. 2. If you cannot solve the problem on site, contact your local dealer for technical support. When the forward power recovers normal value, the prompt message will disappear, and the Alarm Indicator will go out. 7.2 TX/RX Unlock Alarm Normally, after being powered on, the repeater has its TX and RX work properly in locked status. When the TX PLL or RX PLL is unlocked, the Alarm Indicator will glow red and the LCD will display the prompt message below:
17 TX Unlock Alarm RX Unlock Alarm Then certain features of the repeater will be terminated automatically, but the LCD alarm message will remain. And you need to take the following measures:
1. Disconnect the power supply, then open the chassis to check if any cable is loose or damaged. If any cable is loose or damaged, secure or replace that cable. Caution: Disconnect the power supply before opening the chassis. 2. If you cannot solve the problem on site, contact your local dealer for technical support. When the TX/RX Unlock recovers normal operation, the prompt message will disappear, and the Alarm Indicator will go out. 7.3 Fan Failure Alarm When the repeater is operating at high temperature and the fan fails to work, the Alarm Indicator will glow red and the LCD will display the prompt message below:
Then the repeater will automatically work at low TX power, to avoid overheating. And you need to take the following measures:
1. Check whether the fan is blocked by an object. If yes, remove the object. 2. If you cannot solve the problem on site, contact your local dealer for technical support. 18 When the fan recovers normal operation, the prompt message will disappear, and the Alarm Indicator will go out. 7.4 Over Temperature Alarm When the temperature of the PA module exceeds the normal range, the Alarm Indicator will glow red and the LCD will display the prompt message below:
Then the repeater will terminate transmission. And you need to take the following measures to recover transmission:
and 3 to find out the cause. 1. Check whether the temperature of the PA module surface is over 80. If yes, proceed with Step 2 Caution: DO NOT touch the surface of the PA heat sink to avoid burn. You can use a digital thermometer with thermocouple to measure the temperature value. 2. Check whether the ambient temperature and ventilation conditions of the repeater satisfy the foregoing installation requirements. If not, please make improvements as soon as possible by mounting air conditioning equipment, improving equipment ventilation or reducing ambient temperature. antenna/feed line. will go out. 3. Check if connection between the transmitter and RF cable or antenna feed line is loose or damaged. Poor connection between them could cause over high TX power, which would make the temperature of the heat sink rise quickly. If the connection is loose or damaged, secure or replace the cable or 4. If the above measures fail to solve the problem, contact your local dealer for technical support. When temperature falls into normal range, the prompt message will disappear, and the Alarm Indicator 19 7.5 Over/Low Voltage Alarm After being powered on, the repeater will have real-time detection of the voltage inputted by the external power supply. When the voltage is out of the normal range (11V15.6V), the Alarm Indicator will glow red and the LCD will display the prompt message below:
Low Voltage Alarm Over Voltage Alarm Then the repeater will automatically stop working, but the LCD alarm message will remain. And you need to take the following measures:
1. Use voltmeter to check whether the DC power voltage is too low or too high. If the voltage is too low or too high, replace the DC power supply or use external battery. 2. Check whether the DC power cord is loose or damaged. If yes, secure or replace the cord. 3. If you cannot solve the problem on site, contact your local dealer for technical support. When the voltage returns to the normal range, the prompt message will disappear, and the Alarm Indicator will go out. Caution: If low voltage is detected when the repeater is powered by an external battery, please charge it in time. Disconnect the battery from the repeater before charging. 7.6 Voltage Standing Wave Ratio (VSWR) Alarm When transmitting, the repeater will detect the voltage standing wave ratio (VSWR) of the TX antenna of the PA module. Over-high VSWR will damage the PA module or even disable it. When the VSWR exceeds the normal value, the Alarm Indicator will glow red and the LCD will display the prompt message below:
20 Then the repeater will automatically work at low TX power. And you need to take the following measures:
1. Check if the TX frequency is within the frequency range of the antenna. (As improper antenna will result in poor transmitting performance or even damage to the transmitter.) If not, please contact your local dealer to replace the antenna. 2. Check if the connection between the transmitter and RF adapter cable or antenna/feed line is loose or damaged. If yes, please replace the cable. 3. If you cannot solve the problem on site, contact your local dealer for technical support. When the VSWR falls into the normal value, the prompt message will disappear, and the Alarm Indicator will go out. 21 8. Troubleshooting Phenomena Analysis Solution The power cord may be unconnected or not securely Properly connect the power cord and ensure secure connection. Power-on Failure. connected to the outlet. Group members cannot talk to each other, or this repeater cannot communicate with a radio. Group members cannot talk to each other, even though RX indication is given. The fuse in the power cord may be Check if the fuse has blown. If yes, damaged. replace it with a new one. TX/RX frequency of the repeater is inconsistent with that of portable/mobile radios. Check if the frequencies are consistent. Reset them when necessary. Failed to repeat useful signal due to strong interference signal. If you cannot remove or bypass the interference source, change to operate at other frequencies. The group member is out of the coverage of the repeater. Go within the coverage of the repeater. The radio ID is inconsistent with that Set the subscriber ID to the same as of the other group members. that of the other members. The CTCSS/CDCSS of the radio is inconsistent with that of the repeater. Check if the CTCSS/CDCSSs are consistent. Reset CTCSS/CDCSS when necessary. The connecting cable is damaged, Check the damages, replace the cable and the signal energy leaks. with a new one if necessary. Short communication range or poor audio. The antenna connector and the cable may get loose connection or even disconnected. Invisible damage may occur to the cable. Check and secure the cable connector, or replace it if necessary. Replace the cable with a new one. Duplexer is not properly set (if the Contact the manufacturer or your dealer duplexer is mounted). to re-set the duplexer. 22 If the above solutions cannot fix the problems for you, or you may have some other queries, please contact us or your local dealer for more technical support. 23 9. Care and Cleaning To guarantee optimal performance as well as a long service life of the product, please follow the tips below. Product Care Keep the product at a place of good ventilation and heat dissipation to facilitate normal work. Do not place irrelevant articles on top of the product to ensure optimal heat dissipation. Do not pierce or scrape the product. Keep the product far away from substances that can corrode the circuit. Do not place the product in corrosive agents, solutions or water. Product Cleaning Caution: Be sure to power off the product before cleaning. Remove the dust and fine particles on the repeater surface with a clean and dry lint-free cloth or a Use a non-woven fabric with neutral cleanser to clean the keys, control knobs, LCD and connectors after long-time use. Do not use chemical preparations such as stain removers, alcohol, sprays or oil brush regularly. preparations. Make sure the product is completely dry before use. 24 10. Optional Accessories The following items are the main optional accessories for the repeater. For more information of other accessories, please consult your local dealer. Caution: Use the accessories specified by the Company only. If not, Hytera shall not be liable for any losses or damages arising out of use of unauthorized accessories. Power Supply: PS22002 Vehicle Power Supply (220W, backup power applicable) Audio: SM10A1 Desktop Microphone, SM16A1 Palm Microphone Wire: PC37 10pin Programming Cable (USB port), PC40 DB26 Data Cable (USB port), PC49 Back-to-Back Data Cable, Fiberglass-reinforced Plastics Omni-directional Antenna, Directional Yagi Antenna Duplexer: DT11 (Frequency: 380-470MHz; RX-TX spacing: 5-13MHz), DT12 (Frequency:
160-174MHz; RX-TX spacing: 5MHz), DT13 (Frequency: 148-160MHz; RX-TX spacing: 5MHz), DT14
(Frequency: 336-370MHz; RX-TX spacing: 8-13MHz), DT15 (Frequency: 136-148MHz; RX-TX spacing: 5MHz), DT16 (Frequency: 440-480MHz; RX-TX spacing: 5MHz), DT17 (Frequency:
480-512MHz; RX-TX spacing: 5MHz) Others: BRK09 Duplexer Mounting Bracket (for DT11 and DT12 only), BRK12 Rack for Power Supply
(2U)(black), BRK14 Rack for Power Supply (2U)(grey), BRK16 Duplexer Mounting Bracket, BRK18 Power Supply Mounting Bracket, BRK19 Repeater Mounting Bracket 25 11. General Information Antenna information:
Model/Part Number: SC329-HF1SFNF Manufacturer: Sinclair Technologies Frequency Range:
Maximum Gain : 9.6dBi Antenna Type/ Pattern: External Antenna impedance: 50 400-470MHz 26
1 | FCC ID Label | ID Label/Location Info | 847.88 KiB | September 11 2020 |
Peres atau Base Station Channel Unit(CHU) MODEL: CHU-P1BA01 FREQUENCY: 400-470MHz INPUT: 28V 22212. 5A FCC ID:YAMCHU-P1BA01 1C:8913A-CHUP1BA01 productcode 1 UU 141 NES IHN IVUNL (O88) I
*XXXXXXXXX*
ce &
Hytera Communications Corporation Limited CAUTION Device must be restricted to occupational use to satisfy FCC RF exposure compliance.See owner's manual for specific operating requirements.
1 | Attestation Letter | Attestation Statements | 22.30 KiB | September 11 2020 |
Hytera Communications Corporation Limited Add: Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China Tel: +86-755-26972999 Fax: +86-755-86139020 Email: tiantian.chen@hytera.com Justification Letter Date: 2020/8/17 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: YAMCHU-P1BA01 Model number: CHU-P1BA01 Dear Sir/Madam, We, Hytera Communications Corporation Limited, acknowledge that this device will not be marketed to USA users with the frequency band which is not allowed by rule part 90.and it is a violation of FCC rules if this device is operated on unauthorized frequencies inside the U.S.A. This equipment meets the requirements of the FCC Rules, Parts 90.203(e) and (g), as applicable. Programming of this products transmit frequencies can be performed ONLY by the manufacturer or by service or by maintenance personal. The operator cant program transmit frequencies using the equipments external operation controls. This is to certify that the requirements of 47 CFR Part 90.203(j)(4) and (5) spectrum efficiency are met by the Hytera Communications Corporation Limited as demonstrated by the tests conducted on the sample radio provided. The tests show that the 4FSK data rate is in accordance with ETSI TS 102 361-1, that is 9600 bits per second in a 12.5 kHz bandwidth to satisfy the data rate requirement of 4800 bits per second per 6.25 kHz of channel bandwidth (7K60F1D emissions). Additionally the Base Station Channel Unit(CHU) uses the AMBE+2 half-rate vocoder to compress 60 ms of normal bursts are sent in alternate 30 ms TDMA slots and so comply with the equivalence of one voice channel per 6.25 kHz bandwidth
(7K60F1E emission). Sincerely Yours, Signature:
Printed Name: Tiantian Chen Title: Certification Engineer
1 | Confidentiality Letter | Cover Letter(s) | 69.79 KiB | September 11 2020 |
Hytera Communications Corporation Limited Add: Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China Tel: +86-755-26972999 Fax: +86-755-86139020 Email: tiantian.chen@hytera.com FCC Confidential Authorization Date: 2020/8/17 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: YAMCHU-P1BA01 In accordance with Sections 0.457 and 0.459 of the Commissions Rules, Hytera Communications Corporation Limited, hereby requests long-term confidential treatment of information accompanying this application as outlined below:
Block Diagram Schematics Operation Description Parts List/Tune up procedure The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature:
Printed name : Tiantian Chen Title: Certification Engineer QA-FR-171-A
1 | Frequency Justification Letter | Cover Letter(s) | 60.55 KiB | September 11 2020 |
Hytera Communications Corporation Limited Add: Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China Tel: +86-755-26972999 Fax: +86-755-86139020 Email: tiantian.chen@hytera.com Date: 2020/8/17 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Extended Frequencies Justification for Certification of Transmitter with FCC ID: YAMCHU-P1BA01 Dear Sir/Madam, This transmitter was designed to operate in following frequency ranges: 400-470MHz To aid equipment authorization in other countries which accept the United States FCC Grant for Certification, Base Station Channel Unit(CHU) is requesting that the FCC lists the frequencies 400-470MHz, under FCC Rule Parts 22, 74 and 90 on the FCC Grant. Hytera Communications Corporation Limited attests that the Base Station Channel Unit(CHU) will not be marketed to USA users with the frequency band which is not allowed by the rule Parts 22, 74 and 90. Per the FCCs KDB634817 guidance, as an alternative to listing the exact frequencies, we acknowledge that its a violation of the FCC Rules if this device operates on unauthorized frequencies. Frequency Range(MHz) 400-406 406.1-450 450-454 454-455 455-456 456-460 460-462.5375 462.7375-467.5375 467.7375-470 FCC Rule Part For Federal FCC Part 90 FCC Part 74/ FCC Part 90 FCC Part 22 FCC Part 74 FCC Part 22/ FCC Part 90 FCC Part 90 FCC Part 90 FCC Part 90 Also, equipment programming is the responsibility of Authorized Service Personnel, the Base Station Channel Unit(CHU) complies with 47 CFR Part 90.203(e), in that the operator cannot directly program the transmit frequencies using the normally accessible external controls. Please contact me if you require any additional information. Sincerely Yours, Signature:
Printed Name: Tiantian Chen Title: Certification Engineer
1 | Power of Attorney Letter | Cover Letter(s) | 20.29 KiB | September 11 2020 |
Hytera Communications Corporation Limited Add: Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China Tel: +86-755-26972999 Fax: +86-755-86139020 Email: tiantian.chen@hytera.com FCC Authorization Date: 2020/8/17 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern:
We, Hytera Communications Corporation Limited, Hereby authorizes Bay Area Compliance Laboratories Corporation to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratory Corporation on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Clients signature Printed Name: Tiantian Chen Title: Certification Engineer QA-FR-170-B
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2020-09-11 | 406.1 ~ 470 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2020-09-11
|
||||
1 | Applicant's complete, legal business name |
Hytera Communications Corporation Limited
|
||||
1 | FCC Registration Number (FRN) |
0019701887
|
||||
1 | Physical Address |
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District
|
||||
1 |
Hytera Tower, Hi-Tech Industrial Park North
|
|||||
1 |
Shenzhen, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
b******@baclcorp.com
|
||||
1 | TCB Scope |
B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
YAM
|
||||
1 | Equipment Product Code |
CHU-P1BA01
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
T******** C********
|
||||
1 | Title |
Certification Engineer
|
||||
1 | Telephone Number |
+86-7********
|
||||
1 | Fax Number |
+86-7********
|
||||
1 |
t******@hytera.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Base Station Channel Unit (CHU) | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is Maximum rated conducted at antenna terminal. Minimum output setting is 5 W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 200 cm from all persons. A label, as described in this filing must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. RF exposure compliance may be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3). | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bay Area Compliance Laboratories Corp.(Dongguan)
|
||||
1 | Name |
D****** Z********
|
||||
1 | Telephone Number |
0086 ********
|
||||
1 |
q******@baclcorp.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 22,74,9 | EF ES | 400 | 406 | 100 | 1.5 ppm | 7K60F1D | |||||||||||||||||||||||||||||||||
1 | 2 | 22,74,9 | EF ES | 406.1 | 470 | 100 | 1.5 ppm | 7K60F1D | |||||||||||||||||||||||||||||||||
1 | 3 | 22,74,9 | EF ES | 400 | 406 | 100 | 1.5 ppm | 7K60F1E | |||||||||||||||||||||||||||||||||
1 | 4 | 22,74,9 | EF ES | 406.1 | 470 | 100 | 1.5 ppm | 7K60F1E |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC