1 2 | Users Manual | Users Manual | 1.63 MiB |
User Manual for Mendor SMART Blood Glucose Meter Model Name: GM01CAB Manufacturer i-SENS, Inc. www.i-sens.com 43, Banpo-daero 28-gil, Seocho-gu, Seoul 06646, Korea FOR THE USER OF MENDOR SMART BLOOD GLUCOSE METER TABLE OF CONTENTS Thank you for selecting Mendor SMART Blood Glucose Monitoring System. The system provides you with safe, convenient and painless blood glucose in vitro (i.e., outside the body) diagnostic monitoring. You can obtain accurate results in just 5 seconds with a small (0.5 l) blood sample. Mendor SMART Blood Glucose Meter is capable of sending test results to Mendor Balance server by using 3G data transmission. Mendor SMART Blood Glucose Meter securely uploads and manages blood glucose readings, elimi-
nating the need to maintain personal logbooks. Information Table of Contents............................................................................................3 Information: Read This First!...........................................................................4 Important Information.....................................................................................5 Specifications.................................................................................................7 Mendor SMART Blood Glucose Monitoring System Components...................8 Warnings........................................................................................................9 Mendor SMART Blood Glucose Meter Test Strip............................................10 Mendor SMART Blood Glucose Meter..........................................................11 Meter Display................................................................................................12 Main Menu....................................................................................................13 Operating Mendor SMART Blood Glucose Meter..........................................16 Basic Settings..............................................................................................17 Setting up the Date and Time.....................................................17 Setting up the Audio Function.....................................................20 Setting up the Alarm...................................................................21 Network.....................................................................................23 Synchronize................................................................................24 Security Token............................................................................25 Preparation Checking the System....................................................................................26 Control Solution Testing................................................................................27 Testing Testing Your Blood Glucose...........................................................................30 High and Low Message................................................................................33 Additional Function Viewing test results in Mendor SMART Blood Glucose Meters Memory........34 Messages......................................................................................................35 Charging Mendor SMART Blood Glucose Meter...........................................36 Error messages............................................................................................39 Maintenance Caring for Your System.................................................................................41 General Trouble shooting..............................................................................42 Performance Characteristics........................................................................43 Warranty Information....................................................................................44 Manufacturer Information..............................................................................45 INFORMATION: READ THIS FIRST!
IMPORTANT INFORMATION To receive safe and optimum system benefits, please read the entire manual contents before using the system. Please note:
Do not use the system for the diagnosis of diabetes without the guidance of a healthcare professional or for testing newborns. Use only fresh capillary whole blood samples for testing. Wash your hands before each measurement. If water is not available, use disinfectant wipes with 70 % IPA only, dry your hands carefully. Milking of finger may affect result. The following chart explains the symbols you will find in Mendor SMART Blood Glucose Meters user manual, product packaging, and product inserts. Warning: For personal use only. Do not share the device with other users. Consult instructions for use Fragile Caution, consult instructions for use Keep away from sunlight Temperature limitations Use by Do not reuse Manufacturer Batch code In vitro diagnostic medical device Serial number Recyclable package Do not use if package is damaged Sterilised using irradiation Electric and electronic waste Authorized representative in the European community Mendor SMART Blood Glucose Monitoring System is intended for self-
testing and for outside of the body (in vitro diagnostic) use. The glucose in the blood sample mixes with special chemicals on the test strip that produce a small electrical current through a reaction called glucose oxidase. The meter detects this electrical current and measures the amount of glucose in the blood sample. Mendor SMART Blood Glucose Meter is designed to minimize code relat-
ed errors in monitoring by using the no-coding function. The Mendor SMART Blood Glucose Meter should be used only with the Mendor Test Strips. Severe dehydration and excessive water loss may cause false low results. Very high (over 60%) or very low (under 20%) hematocrit can lead to inaccurate test results. If you experience symptoms inconsistent with your test results after following the instructions in this manual, contact your healthcare professional. Follow your local/country laws and regulations for proper disposal of the meter including the rechargeable battery. Make sure to charge Mendor SMART Blood Glucose Meter for at least 3 hours before first use. When fully charged, Mendor SMART Blood Glucose Meter will have a stand-
by time of 3 days (8 measurements per day). The battery life-time is approximately 250 measurements. It is recommended that you charge Mendor SMART Blood Glucose Meter battery at least every 2 days to prevent battery outage. If the meter fails to charge, please contact the manufacturer of the blood glucose meter. If this user manual is not complied with the protection provided by the device may be impaired. Mendor SMART Blood Glucose Meters Test Strips can be used up until the expiration date printed on the test strip vial label if the test strips are used and stored according to the storage and handling conditions presented in this man-
ual. For detailed storage and usage information for test strips, refer also to the Mendor SMART Blood Glucose Meters Test Strip package insert. The equipment complies with applicable EMC emission requirements and it is testes in dynamic electromagnetic fields according to ISO 15197. The equip-
ment is tested for immunity to electrostatic discarge as specified in IEC 61000-
4-2. Emissions of the energy used are low and not likely to cause interference 4 5 IMPORTANT INFORMATION SPECIFICATIONS Caution:
Do not expose the meter to direct sunlight or heat for an extended period of time. Prevent the entry of dirt, dust, blood, or water at the meters test strip port. Do not drop the meter or submit it to strong shocks. Do not try to fix or alter the meter in any way. Keep the meter in a cool and airy place. Keep the meter away from strong electromagnetic fields such as cell phones and microwave ovens. Do not let the equipment come into contact with surfaces which are too hot to touch. Do not use this meter in a dry environment, especially if synthetic materials are present. Synthetic clothes, carpets, etc., may cause damaging static dis-
charges in a dry environment. Do not use this meter near cellular or cordless telephones, walkie talkies, garage door openers, radio transmitters, or other electrical or electronical equipment that are sources of electromagnetic radiation, as these may interfere with the proper operation of the meter. NOTE! If you need assistance with using the Mendor SMART Blood Glucose Meter, please, contact the manufacturer. Product specifications Reported result range 1.1 - 33.3 mmol/L (20 - 600 mg/dL) Sample size Test time Sample type Calibration Assay method Power Rated voltage/
Rated current Memory Dimension Weight Minimum 0.5 l 5 seconds Fresh capillary whole blood Plasma-equivalent Electrochemical 3.7 V / 580m A, Lithium-polymer battery
(Rechargeable type) 5.0 V / 0.5 A
(Charging with micro USB cable) 500 test results 100.5 mm (height) x 48.0 mm (width) x 18.5 mm
(thickness) 59.1g (with battery) Temperature Relative humidity Hematocrit Operating ranges 5 - 50 C (41-122 F) 10 - 90 %
20 - 60 %
6 7 MENDOR SMART BLOOD GLUCOSE MONITORING SYSTEM COMPONENTS WARNINGS Components (provided by the manufacturer):
Mendor SMART Blood Glucose Meter (rechargeable battery included) Mendor SMART Blood Glucose Meter Test Strips User manual Micro USB cable Certain components may not be included depending on the place of purchase. Additionally:
In order to to clean Mendor SMART Blood Glucose Meter you need 70%
isopropyl alcohol available in local pharmacies. In order to to test Mendor SMART Blood Glucose Meter fucntioning you need Mendor SMART Blood Glucose Meter Control Solution available from the manufacturer. NOTE! Please check the completeness and condition of delivery and contact the manufacturer of the blood glucose meter if any component is missing or damaged. NOTE! Please contact your healthcare professional for more information about local disposal requirements for the meter. Read through the warnings before using the device. Basic safety precautions should be taken before using the device including those listed in the Warnings. The Mendor SMART Blood Glucose Meter Test Strips shall be used only with fresh capillary whole blood samples. Do not use venous or arterial blood sam-
ples. Mendor SMART Blood Glucose Meter may lose current displaying data (just measurement data) when battery power is extremely low. Do not test while the battery is being charged. Do not reuse test strips. Do not use test strips past the expiration date. Do not try to open the battery cover or replace the battery. The battery can not be replaced by user. Store Mendor SMART Blood Glucose Meter at a temperature of 0 - 35 C
(32 - 95 F). Store test strips in a cool and dry place at a temperature of 1- 30 C (34 - 86 F). Keep test strips away from direct sunlight or heat and do not freeze. Store test strips only in their original vial. Close the vial tightly immediately after removing a test strip for testing. Do not bend, cut, or alter test strips in any way. Handle test strips only with clean and dry hands. Keep test strips and the test strip vial away from children. The test strips and vial cap may be choking hazards. Drying agents in the bottle cap may be harmful if inhaled or swallowed, or may cause skin or eye irritation. Use this equipment for that purpose only described in this user manual. Do not use accessories which are not recommended in this user manual. Do not use the equipment if it is not working properly or it is visibly broken. Do not insert anything into the devices ports if this is not specifically instructed. KEEP THESE INSTRUCTIONS!
8 9 MENDOR SMART BLOOD GLUCOSE METER TEST STRIP MENDOR SMART BLOOD GLUCOSE METER The Mendor SMART Blood Glucose Meter Test Strip supports the accurate measurement of blood glucose levels in a capillary whole blood sample. Contact bars Gently push the test strip, with its contact bars facing up, into the test strip port of the meter. Confirmation window Check here to see whether sufficient blood sample has been applied. Edge to apply blood sample Apply blood sample here for testing. Detachable vial cap Meter Display Display results and messages. Up/Down Button Select or change cursor or value. Back Button Back to the previous menu. Test Strip Port Insert the test strip here. Sim Card Slot Insert mobile SIM card. Button Turn on/off the meter by pressing the button for 3 seconds. Also, used for menu selection confirmation. Micro USB Port Charge battery or transfer data from the meter to PC. Mendor SMART Test Strip Vial 10 11 METER DISPLAY Main Menu MAIN MENU History The main menu is composed of symbols as shown in the picture below. Using , , and button, you can enter into each menu. When you select History menu, the screen is displayed as shown in the picture below. You can then check measured test results on the screen by using the button. Scroll down to see old test results. Sound On/Off Displays the status of the sound function. PP2 Alarm Appears when the alarm has been set remotely using Mendor Balance. Alarm Symbol Appears when alarm has been set. Year/Month/Day Displays set date. Test Wizard Provides easy step instructions for measuring. Messages Provides Mendor Balance server messages. Message Appears when a new message has been sent. Airplane Mode Displays the status of the Airplane mode. Battery Icon Indicates battery level. Hour/Minute Displays set time. History Displays the test results in the meters memory. Settings To set e.g. date, time, sound and alarm. Latest measured result Displays latest stored result. mmol/L 20.5 6.3 2.1 mmol/L mmol/L Mendor SMART Blood Glucose Meter provides the blood glucose values in 3 different colors (orange, blue and red) to indicate different blood glucose levels, as following:
Orange for measurements above 15 mmol/L (270 mg/dL) Blue for measurements above and equal to 4 mmol/L (72 mg/dL) and below and equal to 15 mmol/L (270 mg/dL) Red color for measurements below 4 mmol/L (72 mg/dL) 12 13 MAIN MENU Test Wizard MAIN MENU Settings When you select Test Wizard menu, the meter gives stepwise instructions for the blood glucose measurement with pictures. In Setting mode, you can set Date/Time, Sound, Alarm, Network, Synchronize and Security Token. Before testing please see section Testing your blood glucose Insertion stage Insert the test strip with contact bars facing upwards. Sound Set up Audio Function and adjust volume. Network Switch connec-
tion On / Off. Security Token Retrieve Security Token for connecting the meter to Mendor Balance. Date/Time Set up current date and time. Choose from 12 or 24 Hour setting and Date notation. Alarm Set up alarm. Synchronize Synchronize meter with the Mendor Balance service. 14 15 OPERATING MENDOR SMART BLOOD GLUCOSE METER BASIC SETTINGS Turn on Mendor SMART Blood Glucose Meter You can start Mendor SMART Blood Glucose Meter by pressing the button for 3 seconds and the display will turn on. When the progress bar animation completes loading, you are ready to use Mendor SMART Blood Glucose Meter. When using the Mendor SMART Blood Glucose Meter for the first time, please, check and update the meters settings prior to using the meter. Setting up the Date and Time Step 1: Enter the Settings mode To enter the setting mode on the main menu, press the , button to position the cursor at Setting. Then, press button and the meter will be in the setting mode. Turn off Mendor SMART Blood Glucose Meter See details in section Testing Your Blood Glucose. Step 2: Enter the Time Settings Enter the Time setting mode, by moving the cursor to Time Setting and then press the button to open the menu where you can adjust the time. Step 3: Select Time Setting type In the Time setting mode, you can select Time setting type (Auto or Manual) by pressing , , and buttons. 16 17 BASIC SETTINGS Step 3a: Auto Set mode In Auto set mode, by pressing Agree button, the meter sets automatically to the local time-
zone. This includes daylight saving. Step 3b: Manual Set mode In Manual Set mode you can adjust the current year, month, day and time by pressing , , and buttons. OK Cancel Step 4: Entering the Time Format In this screen the set time and the current time format is displayed. You can set the time format by pressing time format button. BASIC SETTINGS Step 5: Setting the Time Format The meter provides two options for your convenience. You can choose from 12-Hour or 24-Hour option. 12 Hour format is displayed as HH:MM AM/PM while 24 Hour format is displayed as HH:MM. Step 6: Setting the Date notation The meter provides three options for your convenience. You can choose from yyyy/mm/dd or mm/dd/yyy or dd/mm/yyyy option. For example, yyyy/mm/dd format is displayed as 2014/01/17. 18 19 BASIC SETTINGS Setting up the Audio function Step 1: Setting the Sound (Beep) Enter the Sound mode. The meter provides 2 different sound options: On and Off. If the Sound is turned On the meter makes the beep sound at certain steps when measuring the blood glucose level. (Turning on the meter, inserting the strip, starting Countdown, the test result appears) BASIC SETTINGS Setting up the Alarm Step 1: Entering the Alarm settings In this mode, you can select from Alarm or Result Alarm. Step 2: Deactivating the Sound function (Mute) Selecting the Off button will deactivate (Mute) the sound function. Step 2: Entering the Alarm On the Alarm screen, press +Add to set up the alarm time. Step 3: Setting the Alarm You can select the hour by pressing button then others selections will become blurred. Adjust hour setting by pressing and buttons and pressing button to confirm hour setting. For other settings, do the same as above. Also you can select from On or Off or Delete. If you select Off or button, this alarm is deactivated and the time setting is saved. If you selects Delete, this alarm is deleted. 20 21 BASIC SETTINGS Step 4: Checking the Alarm In this mode, you can see current alarm setting. Check marks indicates that This alarm is activated. Mendor SMART Blood Glucose Meter provides up to 3 regular alarms. If you set up 3 normal alarms, +Add is deacti-
vated (greyed) as shown on the right. Step 5: Entering the Result Alarm In this mode you can activate or deactivate a beep sound to indicate a result that is too high (over 15 mmol/L, 270 mg/dL) or too low (below 4 mmol/L, 72 mg/dL). Select On to activate the function or select Off to deactivate it. Please note, that by turning the sound function Off, you also turn off the Result Alarm. Exiting from Settings After completing meter setting, press the button to exit from Settings. BASIC SETTINGS Network Step 1: Enter the Network Settings Enter the Network settings by moving the cursor to Network and pressing the button. In the Network settings you can switch the meters network connectivity on or off (airplane mode). Step 2: Switching the Network connectivity On/Off To switch the meters network connectivity off, move the cursor to Off and press the button. An airplane symbol appears to the upper edge of the display, indicating that the meter is now in airplane mode. To switch the meters network connectivity back on, move the cursor to On and press the button. Please note that when your meter is connected to a Balance account, all the measurements you have made in airplane mode will be uploaded to your account at the same time once you do a measurement or use the Synchronize function with the network connectivity switched on again. 22 23 BASIC SETTINGS Synchronize BASIC SETTINGS Security Token Step 1: Synchronizing the meter with Balance Step 1: Retrieving the Security Token When using the meter with Balance, the Synchronize function can be used to upload measurements from the meters memory to your Balance account (if you have been using the meter in airplane mode or out of net-
work range), as well as synchronizing alarms and mes-
sages when you are doing a glucose profiling program in Balance. To synchronize the meter with Balance, move the cur-
sor to Synchronize and press the button. You will see the loading circle and the text Please wait while the meter synchronizes. Step 2: Synchronization complete Once the synchronization is complete, you will see the text Your meter has been successfully synchronized. Press the button to get back to the Settings menu. Security Token is a code which is needed for connect-
ing the meter to a Balance account. Move the cursor to Security Token and press the button to retrieve the code. You will see the loading circle and the text Please wait while the Security Token is being retrieved. Step 2: Security Token received After a little while you can see the Security Token in the display. You can use the token to connect the meter while creating a new Balance account, or you can connect the meter to an already existing account. One meter can only be connected to one account at a time. The Security Token needs to be retrieved only once when you start using the meter with Balance. Please note that the Security Token is valid for one hour after retrieval if you dont connect the meter to a Balance account within that time, you need to retrieve a new Security Token. 24 25 CHECKING THE SYSTEM History You may check your meter and test strips using Mendor SMART Blood Glucose Meter Control Solution, which contains a known amount of glucose and is used to check that the meter and the test strips are working properly. The test strip vials have Mendor SMART Blood Glucose Meter Control Solution ranges printed on their labels. Compare the result displayed on the meter to Mendor SMART Blood Glucose Meter Control Solution range printed on the test strip vial. Before using a new meter or a new vial of test strips, conduct a control solution test following the procedure on page 25 - 26. Notes:
Use only Mendor SMART Blood Glucose Meter Control Solution. Check the expiration date printed on the bottle. When you first open the control solution bottle, record the discard date
(date opened plus 3 months) in the space provided on the label. Make sure your meter, test strips, and control solution are at room temperature before testing. Control solution tests must be done at room temperature (20 -
25 C, 68 - 77 F). Before using the control solution, shake the bottle, discard first few drops and wipe the tip clean. Close the control solution bottle tightly and store at a temperature of 8 - 30 C
(46 - 86 F). Do a control solution test:
When using the meter for the first time. Whenever you open a new vial of test strips. If the meter or test strips do not function properly. If your symptoms are inconsistent with the blood glucose test results and you feel that the meter or test strips are not working properly. If you drop the meter or suspect the meter has been damaged. NOTE! Mendor SMART Blood Glucose Meter Control Solution and Strips can be purchased separately. Please contact the manufacturer of the blood glucose meter. 26 CONTROL SOLUTION TESTING Checking with control solution Step 1 Insert a test strip with contact bars facing upwards into the strip port. Push the strip gently until the meter beeps. The meter will automatically turn on and the blood symbol will appear indicating the meter is ready to test blood glucose Step 2 In measurement mode, you can switch to control solution mode pressing button for 3 seconds. You should use the proper control solution. When the screen display is as shown on the right, apply the control solution to the test strip. Step 3 Shake the control solution bottle well. Discard the first drop of control solution and squeeze a small drop of the control solution on a clean non absorbent surface, such as the cleaned cap of control solution bottle. Apply the control solution to the narrow edge of the test strip until the meter beeps. Make sure the confirmation window fills completely. 27 CONTROL SOLUTION TESTING Step 4:
The test result will appear after the meter counts down from five (5) to one (1) in 5 seconds. You can see the control solution mark Check on screen. In this case, the result is stored in the meter memory but not included in the averages. Step 5 Compare the result with the control solution range printed on the Mendor SMART Blood Glucose Meter Test Strip bag. The result should fall within that range. Used strips should be discarded safely in dis-
mmol/L6.7 CONTROL SOLUTION TESTING Comparing the Control Solution Results If your control solution test results do not fall within the range printed on the test strip vial, repeat the test. Out of range results may occur due to the following factors:
When the control solution bottle was not shaken well When the control solution is past its expiration date or is contaminated When the meter, the strip or the control solution were exposed to high or low temperatures When the first few drops of the control solution were not discarded, or the tip of the vial was not wiped clean When the test strip is past its expiration date When the meter is not functioning properly NOTE! If you cannot perform an acceptable control measurement (that falls within the control range) do not use the blood glucose monitoring system and contact the manufacturer of the blood glucose meter. 28 29 TESTING YOUR BLOOD GLUCOSE TESTING YOUR BLOOD GLUCOSE Small children (under the age of 10) and handicapped or invalid persons need to be supervised when they use the equipment. Applying Blood Sample Step 3 Preparing the Meter and Test Strip Step 1 Prepare the usable test strip and lancet. Insert a test strip with contact bars facing up into the strip port. Push the strip gently until the meter beeps. The blood symbol will appear indicating that the meter is ready to test. Step 2 The meter is ready for the blood sample. In this mode, you may switch to control solution mode by pressing button for 3 seconds, see Control Solution Testing for more detailed information. Obtain a blood sample using a lancing device. Wait a few seconds for a blood drop to form. A minimum volume of 0.5 micro liter is needed to do the test. (actual size of 0.5 l: ). Always use a fresh sample for the measurement. Step 4 While the symbol is blinking, apply the blood sample to the narrow edge of the test strip untill the meter beeps. If the confirmation window is not filled in time because of abnormal viscosity or insufficient volume, an error message will appear. NOTE! The meter may switch off if the blood sample is not applied within 2 minutes of the apply blood sample screen. If the meter turns off, press button or remove and reinsert the un-used strip to turn on the meter. 30 31 TESTING YOUR BLOOD GLUCOSE HIGH AND LOW MESSAGE Step 5 The test result (in mmol/L) will appear after the meter counts down from five to one (5-to-1). The result is equivalent to your plasma glucose concentration. 6.2mmol/L Step 6 After finishing the test, remove the test strip 6.2mmol/L Mendor SMART Blood Glucose Meter displays test results between 1.1 -
33.3 mmol/L (20 - 600 mg/dL). Please refer to the instructions below, if you receive a High or Low message. High Message The High message appears when the blood glu-
cose level is above 33.3 mmol/L (600 mg/dL) and may indicate hyperglycemia (high blood glucose). If the Hi message is displayed again on retesting, please contact your healthcare professional immediately. Low Message The Low message appears when the blood glucose Level is below than 1.1 mmol/L (20 mg/dL) and indicates hypoglycemia (low blood glucose). If the Low message is displayed again on retesting, please contact your healthcare professional immediately. 33.3 mmol/L 1.1 mmol/L NOTE! If the HIGH/LOW messages persist after measuring several times and your feelings do not match with the results contact your healthcare professional. NOTE! Follow the instructions given by your physician when interpreting the re-
sults. Do not alter your treatment on the basis of meter readings before consulting your healthcare professional. If an error message appears see section Error Messages. 32 33 MESSAGES Step 1 On the Message menu, you can see messages regard-
ing the monitoring of your blood glucose levels sent from Mendor Balance server. By pressing button, you can see the messages. VIEWING TEST RESULTS IN MENDOR SMART BLOOD GLUCOSE METERS MEMORY Mendor SMART Blood Glucose Meter stores the last 500 glucose test results with time and date. If the memory is full, the oldest test result will be replaced by new test results. Mendor SMART Blood Glucose Meter also calculates averages from last 1/7/14/30/90 days starting from the current time and date shown on the meter. The following gives you instructions to view the test results. Step 1: Viewing the measurement result history Entering the History menu, you can check your measured test results on the screen as shown on the right. You can move in the menu by pressing the and buttons. Test results are provided with measurement date, check mark and colored letters. You can check your average data by pressing button. Step 2: Viewing the measurement result averages Press button when you have entered the History menu (screen looks like Step 1), now you can check your 1/7/14/30/90 day average results. You can see 90 day average result by pressing button. mmol/L 20.5 6.3 2.1 mmol/L mmol/L 6.3 6.3 6.3 6.3 mmol/L mmol/L mmol/L mmol/L Exiting from History Press back button to exit from history to main menu or to turn off the meter by pressing button for 3 seconds. 34 35 CHARGING MENDOR SMART BLOOD GLUCOSE METER CHARGING MENDOR SMART BLOOD GLUCOSE METER Step 1 Step 2 Connect the end of the micro USB cable to the meter charging port. Then plug the other end of the cable to the USB port on your computer or other powered USB socket. The meter charging port is located on the bottom of the meter. Once the micro USB cable is plugged in, the meter displays USB connection status as below. Once the meter is connected, it is going to start charging and the charging icon will be displayed on the screen. Plug into your computer Plug into the meters Charging port 36 Mendor SMART Blood Glucose Meter displays the battery status with 6 image Battery status 0 - 10 %
11- 20 %
21 - 40 %
Without charging
(Status bar) With charging
(Whole Display) Battery status Without charging
(Status bar) With charging
(Whole Display) 41 - 80 %
81 - 99 %
100 %
When the meter is on, the battery icon is shown in the top right corner. The icon shows the battery power status. 37 CHARGING MENDOR SMART BLOOD GLUCOSE METER ERROR MESSAGES When the meter starts charging, the battery icon and its status will be displayed on the screen as shown on the previous page. If error occurs while using the meter, the error screen is displayed and the me-
ter provides a quick solution for resolving the problem. Caution:
Only use provided Micro USB cable. Do not charge the meter in high humidity or in a wet area. Do not use the Micro USB cable if it is damaged, abnormally hot or discolored. Do not allow children to charge the meter. Do not insert Test strip while the meter is charging. Before charging the meter, check that the supply voltage is correct. When charging the meter, plug the equipment into a supply outlet which has an earth connection. Do not place the equipment in liquid, nor put it where it could fall into liquid. If the equipment becomes wet, unplug it before touching it. Do not leave the equipment unattended for long periods of time while it is plugged in. While charging the meter, do not place anything on top of the equipment. DANGER Misuse of electrical equipment can cause electrocution, burns, fire and other HAZARDS. Error 1 Cause Solution Error 2 Cause Solution Error 3 Cause Solution Used test strip Repeat the test with a new test strip. The sample has been applied before the blood symbol appeared. Repeat the test with a new test strip and wait until the blood symbol appears. The temperature during the test was above or below the operating range. Move to an area where the tem-
perature is within the operating range (5 - 50 C / 41-122 F) and repeat the test after 30 minutes. 38 39 ERROR MESSAGES CARING FOR YOUR SYSTEM Use a soft cloth or tissue to wipe the meter exterior. If necessary, the soft cloth or tissue might be dipped in a small amount of 70% isopropyl alcohol. Do not use organic solvents such as benzene, acetone, or household and industrial cleaners that may cause irreparable damage to the meter. Store all the meter components in the portable case to prevent loss. Error 4 Cause Solution Error 5 Cause Solution Error 6 Cause Solution The sample was not large enough or it was too thick. Repeat the test with a new test strip. Strip insertion error. Please insert a Mendor test strip properly. Meter failure. Contact the manufacturer of the blood glucose meter. NOTE! You can see quick solution by pressing button (scroll the display). NOTE! If the error messages persist, please contact the manufacturer of the blood glucose meter. 40 41 GENERAL TROUBLE SHOOTING PERFORMANCE CHARACTERISTICS Problem Troubleshooting The display is blank even after inserting a test strip. Check whether the test strip is inserted with the contact bars facing up. Check if the strip has been inserted completely till the end. The test does not start even after applying the blood sample on the strip. The test result does not match your expectation. Check if the confirmation window is filled adequately. Repeat the test after inserting a new test strip. Repeat the test after inserting a new test strip. Check the validity period of the test strip. Perform a test with control solution to verify the strips are OK. Check the meter. The performance of Mendor SMART Blood Glucose Monitoring System has been evaluated in laboratory and in clinical tests. Accuracy:
The accuracy of Mendor SMART Blood Glucose Meter System
(Model:GM01CAB/GM01CAD) was assessed by comparing blood glucose results obtained by patients with those obtained using a YSI Model 2300 Glucose Analyzer, a laboratory instrument. The following Results were obtained by 100 diabetic patients at clinic centers. System accuracy results for glucose concentration < 4.17 mmol/L (< 75 mg/dL) Within 0.28 mmol/L
(Within 5 mg/dL) 74/96 (77.1%) Within 0.56 mmol/L
(Within 10 mg/dL) 94/96 (97.9%) Within 0.83 mmol/L
(Within 15 mg/dL) 96/96 (100%) System accuracy results for glucose concentration 4.17 mmol/L ( 75 mg/dL) Within 5 %
249/504 (49.4%) Within 10 %
401/504 (79.6%) Within 20 %
493/504 (97.8%) Within 20 %
504/504 (100%) Results from repeatibility evaluation Interval 1 2 3 4 5 Glucose concentration mmol/L 1.7 to 2.8 2.9 to 6.1 6.2 to 8.3 8.4 to 13.9 14.0 to 22.2 Pooled SD or CV 0.1 mmol/L 0.1 mmol/L 2.8 %
2.7 %
3.0 %
NOTE! If the problem is not resolved, please contact the manufacturer of the blood glucose meter. 42 43 WARRANTY INFORMATION Manufacturers Warranty Mendor warrants that the meter shall be free of defects in material and work-
manship in normal use for a period of two (2) years. The meter must have been subjected to normal use. The warranty does not cover improper handling, tampering use or service of the meter. All claim must be made within the warranty period. Mendor will, at its discretion, repair or replace a defective meter or meter part that is covered by this warranty. As a matter of warranty policy, Mendor will not reimburse the consumers purchase price. Obtaining Warranty Service To obtain warranty service, you must return the defective meter or meter part along with proof of purchase to the manufacturer. MANUFACTURER INFORMATION i-SENS, Inc. 43, Banpo-daero 28-gil, Seocho-gu, Seoul 06646, Korea tel. 1-800-429-5001 www.i-sens.com Manufacturer i-SENS, Inc. www.i-sens.com 43, Banpo-daero 28-gil, Seocho-gu, Seoul 06646, Korea 44 Art. PM062011L04_A Rev. 10/14 45 FCC Part 15.19 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Part 15.21 Any changes or modifications (including the antennas) to this device that are not expressly approved by the manufacturer may void the user's authority to operate the equipment. FCC Part 15.105 (B) Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. Modifications not expressly approved by the manufacturer could void the user authority to the operated equipment under FCC rules. RF Exposure Statement (2.1093) This equipment complies with FCC RF Radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 5mm between the radiator and your body.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2015-05-04 | 1852.4 ~ 1907.6 | PCB - PCS Licensed Transmitter | Original Equipment |
2 | JBP - Part 15 Class B Computing Device Peripheral |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2015-05-04
|
||||
1 2 | Applicant's complete, legal business name |
i-SENS, Inc.
|
||||
1 2 | FCC Registration Number (FRN) |
0021843529
|
||||
1 2 | Physical Address |
43, Banpo-daero 28-gil, Seocho-gu, Seoul
|
||||
1 2 |
SEOUL, N/A 06646
|
|||||
1 2 |
South Korea
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
L******@ul.com
|
||||
1 2 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
1 2 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 | Grantee Code |
OEL
|
||||
1 2 | Equipment Product Code |
GM01CAB
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
M**** L********
|
||||
1 2 | Telephone Number |
82-2-********
|
||||
1 2 | Fax Number |
82-2-********
|
||||
1 2 |
m******@i-sens.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 10/27/2015 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | PCB - PCS Licensed Transmitter | ||||
1 2 | JBP - Part 15 Class B Computing Device Peripheral | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Blood Glucose Meter | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Output power is ERP below 1GHz and EIRP above 1GHz. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. The highest reported SAR value under this filing is 1.18 W/Kg. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
SGS Korea Co., Ltd
|
||||
1 2 | Name |
J**** C********
|
||||
1 2 | Telephone Number |
82-31********
|
||||
1 2 | Fax Number |
+82-3********
|
||||
1 2 |
K******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 22H | 826.4 | 846.6 | 0.069 | 2.5 ppm | 4M17F9W | ||||||||||||||||||||||||||||||||||
1 | 2 | 24E | 1852.4 | 1907.6 | 0.369 | 2.5 ppm | 4M18F9W | ||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15B |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC