System Setup 1 Boot up room panel 2 4 Mounting and Installation Option 1: Flush Wall Mount Step 1 Step 2 Step 3 Paste the mount sheet on the wall Step 4 Step 5 Drill the four mounting holes Install the mounting plate using the four screws Step 6 Step 7 Screw M3*13 Screw M3*13 Screw of cover plate Screw of cover plate Plug in the required cables to the room panel Option 2: Mounting on Glass Step 1 Step 2 Attach the room panel to the mounting plate Lock the room panel to the mounting plate using a screw at each corner The room panel is ready to be brought online Step 3 Step 4 Paste sticker on the back of the mounting plate Ensure the glass surface is clean and dry The mount sheet can be temporary fixed on the other side of the glass to locate the area for the cover sheet. 1.Affix the cover sheet to the glass surface. 2.Align the mounting plate to the cover sheet with the kensington lock hole. Step 5 Step 6 Step 7 Step 8 Affix the mounting plate to the glass surface Screw M3*13 Screw M3*13 Cover sheet Screw of cover plate Screw of cover plate Plug in the required cables to the room panel Attach the room panel to the mounting plate Lock the room panel to the mounting plate using a screw at each corner The room panel is ready to be brought online Option 3: Mounting close to a window frame Step 1 Step 2 Step 3 Step 4 Window frame Window frame Window frame Align the mounting sheet guide parallel to the window frame Drill the four mounting holes Install the mounting plate using the four screws Plug in the required cables to the room panel Step 5 Window frame Step 6 Window frame Step 7 Window frame Screw M3*6 Screw M3*13 Screw of cover plate Attach the room panel to the mounting plate Lock the room panel using a screw at the top, and two screws at the outside corners The room panel is ready to be brought online To change room panel system language, select
(Current Language) .... rations, select Advanced.
configurations:
1 2 3 Set correct time, date, and time zone for properly scheduled playback. Set password to prevent unauthorized access during setup menu. Set network for establishing network connection. 5 Set content Users can set content by clicking "Set Content" to enter the URL or use the desired content manage-ment system to upload the contents onto the room panel. Content Management content management solution. Troubleshooting How do I interrupt playback and enter setup menu?
Use USB mouse to click and hold one corner of the screen for 10 seconds to exit playback and enter setup menu. How do I provide a DEBUG log for a misbehaving room panel to the support team?
Please follow the instructions below to collect the room panel's DEBUG log:
Prepare a blank USB stick in FAT-32 format. Create a folder named "DEBUG" (case insensitive) in the root of USB stick. Make sure the room panel is operating (see welcome screen or playing content). Insert the USB stick into room panel and wait for Within the "DEBUG" folder, is a folder with a string of number as its name. If the string of numbers are all zero's, the debug log has not been collected properly. Repeat step 1-4 again and make sure to wait
. 6 Zip the"DEBUG" folder and send to IAdea Support Team. Resetting room panel to factory default Factory resetting the room panel will result in the removal of all saved contents, to complete the room panel factory resetting process:
Use a pen to press and hold the reset button - do not release until Step 4. Insert the power cord. Wait 30 seconds for the system reboot indicating your data is erased. Release the reset button and your room panel will initialize in factory default state. IAD_DGS_WRP_10EP 1 2 3 4 5 1 2 3 4 CARE AND WARNING CAUTION Risk of explosion if the battery is replaced by an incorrect type Wait one-half hour after switching off before handling parts
- Replacement of a battery with an incorrect type that can be defeat a safeguard;
- Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;
- Leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas;
- A battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas. Room booking Mounting plate Glass mount Mounting guide panel sticker sheet Glass mount cover sheet Screw M3*13 Screw M3*6 Europe EU Declaration of Conformity Front View 261.7*181.6(mm) x 3 x 2
(1 Spare)
(1 Spare) IAD-18010 series Quick Start Guide Box Content This is a quick walkthrough of the set up process. For complete documentations and quick start guides, please visit http://support.IAdea.com. Port Connections 1 4 43 5 11 1 1 2 1 16 17 MicroSD ADB Audio USB Reset USB Ethernet DC Expansion Power LED 6 7 8 9 10 11 12 13 14 15 1 Screw Hole 2 Camera*
3 Microphone*
4 LED 5 NFC/RFID reader 6 MicroSD card slot 7 ADB 8 3.5mm audio 9 USB port 10 Reset 11 USB port 12 Ethernet RJ45 13 Power LED 14 12V DC power 15 Expansion*
16 Kensington Lock 17 VESA mount (MIS-D75) Screw spec: M4
* The functions marked with "*" only appear on certain models. WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with the essential requirements of the Radio Equipment Directive
(2014/53/EU). The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the Radio Equipment Directive This equipment is compliant with Class A of EN55032. In a residential environment this equipment may cause radio interference. Correct Disposal of this product. This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. FCC & CE RF Radiation Exposure Statement Caution: To maintain compliance with the FCC & CEs RF exposure guidelines, place the product at least 20cm from near by persons. The suitable temperature for the Colour Monitor and sccessories is 0C-50C. Adaptor with ferrite must be used with this equipment to ensure compliance with the Class A FCC limits. Power Adapter information:
Model No.: WB-24J12R INPUT: 100-240V~50/60Hz OUTPUT: 12 2.0A Installation height :<2M company Name: IAdea Corporation Address: 3F, No. 21, Lane 168, Xingshan Road,Neihu Dist. Taipei, 114 Taiwan Tel: 886-2-2791-1110 Q41G78SP05904A