FCC ID: AFJ307702 UHF P25 Trunking Mobile Transceiver

by: ICOM Incorporated latest update: 2014-12-18 model: 307702

Two grants have been issued under this FCC ID from 09/16/2009 to 12/18/2014 (this is one of thirty-seven releases in 2014 for this grantee). Public details available include frequency information, internal & external photos, and manuals. some products also feature user submitted or linked drivers, instructions, warrantee terms, troubleshooting guides, & password defaults.
permalink for this FCC identifier
search for: Repair details
from iFixIt
Replacement
on Amazon
Trade-in? Recycling locations
eg is reader-supported. when you buy through links on our site, we may earn an affiliate commission.
|
|
|   
eg for Slack usage
app s submitted / available
1 2 User Manual Users Manual pdf 1.21 MiB
1 2 Cover Letter(s) pdf
1 2 Cover Letter(s) pdf
1 2 Cover Letter(s) pdf
1 2 Cover Letter(s) pdf
1 2 Test Setup Photos pdf
1 2 Test Report pdf
1 2 Internal Photos pdf
1 2 External Photos pdf
1 2 Attestation Statements pdf
1 2 Internal Photos pdf
1 2 Attestation Statements pdf
1 2 ID Label/Location Info pdf
1 2 Attestation Statements pdf
1 2 RF Exposure Info pdf
1 2 Test Setup Photos pdf
1 2 User Manual Users Manual pdf 1.21 MiB

frequency equipment class purpose
1 2014-12-18 450 ~ 512 TNB - Licensed Non-Broadcast Station Transmitter Class II permissive change or modification of presently authorized equipment
2 2009-09-16 450 ~ 512 TNB - Licensed Non-Broadcast Station Transmitter Original Equipment

Application Forms

app s Applicant Information
1 2 Effective 2014-12-18
1 2 2009-09-16
1 2 Applicant's complete, legal business name ICOM Incorporated
1 2 FCC Registration Number (FRN) 0005855366
1 2 Physical Address 1-1-32 Kamiminami
1 2 Osaka, N/A 547-0003
1 2 Japan
app s TCB Information
1 2 TCB Application Email Address v******@ultratech-labs.com
1 2 TCB Scope B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
app s FCC ID
1 2 Grantee Code AFJ
1 2 Equipment Product Code 307702
app s Person at the applicant's address to receive grant or for contact
1 2 Name A****** T******
1 2 Title General Manager
1 2 Telephone Number +8166********
1 2 Fax Number +8166********
1 2 E-mail w******@icom.co.jp
app s Technical Contact
1 2 Firm Name UltraTech Engineering Labs Inc.
1 2 Name J**** C********
1 2 Physical Address 3000 Bristol Circle
1 2 Oakville, ON, L6H6G4
1 2 Canada
1 2 Telephone Number 905-8********
1 2 Fax Number 905-8********
1 2 E-mail j******@ultratech-labs.com
app s Non Technical Contact
n/a
app s Confidentiality (long or short term)
1 2 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 2 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:No
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 2 Is this application for software defined/cognitive radio authorization?No
1 2 Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
1 2 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)UHF P25 Trunking Mobile Transceiver
1 2 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?No
1 2 Modular Equipment TypeDoes not apply
1 2 Purpose / Application is forClass II permissive change or modification of presently authorized equipment
1 2 Original Equipment
1 2 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?No
1 2 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?No
1 2 Grant CommentsPower output listed is the manufacturers rated output. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 38 cm from all persons. This radio must operate in push-to-talk mode with a duty factor not exceeding 50%, must be restricted to work related operations in an Occupational/ Controlled RF exposure environment, and must not be co-located or operating in conjunction with any other antenna or transmitter. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational /controlled exposure limit users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Class II permissive change to replace PLL IC on the main unit, and add FCC rules 22, 74 and 80 services on the grant.
1 2 Power output listed is the manufacturers rated output. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 38 cm from all persons. This radio must operate in push-to-talk mode with a duty factor not exceeding 50%, must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, and must not be co-located or operating in conjunction with any other antenna or transmitter. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled exposure limit Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.
1 2 Is there an equipment authorization waiver associated with this application?No
1 2 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 2 Firm Name UltraTech Engineering Labs Inc.
1 2 Name T**** L****
1 2 Telephone Number 905-8********
1 2 Fax Number 905-8********
1 2 E-mail t******@ultratech-labs.com
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 22,74,80,9 EF 450 512 50 1 ppm 11K0F3E
1 2 22,74,80,9 EF 450 512 5 1 ppm 11K0F3E
1 3 22,74,80,9 EF 450 512 50 1 ppm 8K10F1E
1 4 22,74,80,9 EF 450 512 5 1 ppm 8K10F1E
1 5 22,74,80,9 EF 450 512 50 1 ppm 8K10F1D
1 6 22,74,80,9 EF 450 512 5 1 ppm 8K10F1D
1 7 22,74,8 EF 450 512 50 1 ppm 16K0F3E
1 8 22,74,8 EF 450 512 5 1 ppm 16K0F3E
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
2 1 90.21 EF 450 512 50 1 ppm 16K0F3E
2 2 90.21 EF 450 512 50 1 ppm 11K0F3E
2 3 90.21 EF 450 512 50 1 ppm 8K10F1E
2 4 90.21 EF 450 512 50 1 ppm 8K10F1D
2 5 90.21 EF 450 512 5 1 ppm 16K0F3E
2 6 90.21 EF 450 512 5 1 ppm 11K0F3E
2 7 90.21 EF 450 512 5 1 ppm 8K10F1E
2 8 90.21 EF 450 512 5 1 ppm 8K10F1D

 

some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details

 

  This product uses the FCC Data API but is not endorsed or certified by the FCC