S T A R R F 7 0 P R O X I M I T Y R E A D E R USERS MANUAL Proximity Reader 20021214 1 USERS MANUAL S T A R R F 7 0 P R O X I M I T Y R E A D E R CONTENTS 1. Introduction 2. Identifying supplied parts 3. Specification 4. Installation 5. Jumper location 6. Wire Color Table of RF70 7. Wire Connection to Controller 8. Operation 9. FCC Registration Information 10. Warranty and Service page 3 page 3 page 3 page 4 page 5 page 6 page 6 page 7 page 7 page 8 20021214 2 USERS MANUAL S T A R R F 7 0 P R O X I M I T Y R E A D E R 1. Introduction The STAR RF70 is a Long Range Proximity Reader for outdoor use and the read range of RF70 is a maximum 7 -foot distance with IDA200 active cards. RF70 can be used for various application such as Hands F ree Access Control, Parking Control and Factory Automations. The RF70 supports various output formats, 26bit Wiegand output, ABA Track II Magstripe output and RS232 serial output and there is an optional mounting bracket to install the RF70 to a mounting pole. The RF70 has built-in tuning circuitry for the exact tuning for maximum read range wherever RF70 is mounted to different materials. The two-color LED of green and red and the inside beeper sound will guarantee you accurate and reliable system operations. 2. Identifying supplied parts Please unpack and check the contents of the box. RF70 3. Specification Users Manual Mounting Bracket (Optional purchase) Read Range Output Format Up to 28 (70cm) with IDC170 cards Up to 5 foot (1.5m) with IDA150 cards Up to 7 foot (2.1m) with IDA200 cards 26 bit Wiegand, ABA Track II Magstripe, RS232 External Beeper Control Input Low Active, DC 0 ~ 12V, maximum 50 mA External LED Control Input Low Active, DC 0 ~ 12V, maximum 50 mA 2-Color LED (Red and Green) / Piezo Buzzer LED/Beeper Light Gray, Dark Gray DC12V, maximum 500mA
-31 ~ 149(-35 ~ +65), 0~90% Humidity Color Power Operating Environment Overall Size (WxHxD) Weight 11.4"x 11.4"x2.4" (290x290x60mm) 7.0 lbs (3.2kg) 20021214 3 USERS MANUAL S T A R R F 7 0 P R O X I M I T Y R E A D E R 4. Installation 4-1. Pole Mount using Mounting Bracket (Optional purchase) Install the RF70 to the mounting plate and instal l the mounting bracket to the pole as shown in the photos below, and then adjust the angle of the reader toward the tags.
(1) Install mounting plate to RF70
(2) Assemble U bolt to bracket by using 8 screws
(3) Assemble bracket to mounting plate by using 2 hex bolts/nuts
(4) Install mounting bracket to the pole then adjust the angle of the reader 20021214 4 USERS MANUAL S T A R R F 7 0 P R O X I M I T Y R E A D E R 5. Jumper location Open the top cabinet and t here are 5 jumpers in the unit and the location of jumpers are shown in the photo below. The jumpers needs to be set as shown below. JUMPER ON/OFF JP1 Off JP2 On JP3 On JP4 On JP5 On 20021214 5 USERS MANUAL INPUT BEEP LED CP CLK Data Red wire Black wire Green wire White wire Blue wire Yellow wire DC(+) DC(-)(GND) S T A R R F 7 0 P R O X I M I T Y R E A D E R 6. Wire Color Table of RF70 POWER Power (DC +12V) Power (DC Ground) Beeper control input LED control input OUTPUT (Wiegand Format) Data-0 Wiegand Data-0 Wiegand Data-1 Data-1 OUTPUT (ABA Track II Format) ABA(Card Present) ABA(Clock) ABA(Data) Note: All ABA Track II outputs are open collector output. 7. Wire Connection to controller Orange wire White wire Green wire 20021214 6 USERS MANUAL S T A R R F 7 0 P R O X I M I T Y R E A D E R 8. Operation 8-1. Once power is applied, you should hear three beeping sounds and LED changes color to red-green-red indicating that the reader is in standby mode after a successful initialization and diagnosis. 8-2. Present proximity card to the reader until you hear the beeping sound and see the LED changes color to green. The reader will send the proximity card data to the controller then the LED will change color to red again for the next reading. 8-3. LED Control:
To change the LED colors, you may connect the LED Control Input (Yellow wire) to ground and the green LED will turn on indicating that the reader is in standby mode. Present proximity card and the LED will change color to red then green again for the next reading. 8-4. Beeper Control:
In normal operation, the reader generates one beep when it reads a proximity card, however additional beeps can be generated to improve indication for access status
(granted or denied) by forcing the beeper control input (Blue wire) to system ground level. The beeper will remain on as long as the Blue wire is connected to system ground. 9. FCC REGISTRATION INFORMATION FCC REQUIREMENTS PART 15 Caution: Any changes or modifications in construction of this device which are not expressly approved by the responsible for compliance could void the user's authority to operate the equipment. NOTE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions;
1. This device may not cause harmful interface, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to this equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the radio or television off and on, the user is encouraged to try to correct interference by one or more of the following measures. 20021214 7 USERS MANUAL S T A R R F 7 0 P R O X I M I T Y R E A D E R 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on another circuit. 4. Consult the dealer or an experienced radio/TV technician for help. 10. Warranty and Service The following warranty and service information applies only to the United States of America and Republic of Korea. For the information in other countries, please contact your local distributor. To obtain in or out of warranty service, please prepay shipment and return the unit to the appropriate facility listed below. OUTSIDE OF THE UNITED STATES ID TECK CO., LTD. Service Center 5F Ace Techno Tower Bldg., 684-1 Deungchon-dong, Gangsuh-gu, SEOUL 157-030, KOREA Tel.: +82 (2) 2659-0055 Fax.: +82 (2) 2659-0086 E-mail: webmaster@idteck.com Web-site: www.idteck.com IN THE UNITED STATES RF LOGICS Inc. Service Center 3026 Scott Blvd., SANTA CLARA, CA95054 Tel.:
Fax.:
E-mail: rflogics@rflogics.com Web-site: www.rflogics.com Please use the original container, or pack the unit(s) in a sturdy carton with sufficient packing to prevent damage, include the following information:
1. A proof-of-purchase indicating model number and date of purchase. 2. Bill-to address 3. Ship-to address 4. Number and description of units shipped. 5. Name and telephone number of person to contact. 6. Reason for return and description of the problem. NOTE: Damage occurring during shipment is deemed the responsibility of the carrier, and
(408) 980-0001
(408) 980-8060 claims should be made directly to the carrier. 20021214 8 USERS MANUAL