IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER- Risk of shock- Disconnect power before installation. DANGER Risque de choc Couper lalimentation avant linstallation. 2. Must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit tre install conformment NEC ou votre code lectrique local. Si vous ntes pas familier avec ces codes et ces exigences, veuillez contacter un lectricien qualifi. Indoor use only and Suitable for Damp Locations. Pour usage interieur seulement et convient aux emplacements humides. 3. 4. This equipment shall be installed and operated with a minimum distance 20cm between the radiator and your body. Lquipement doit etre installe dune facon quune distance minimum de 20cm soit maintenue entre lemetteur et toute partie du corps. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE NOTE:
Not for use with equipment that requires constant power or equipment that presents a hazard if automatically energized. Devices requiring soft shutdown
(such as computers) or other power related requirements (such as projectors, DVRs or Clocks) may not be compatible. 1 2 Insert Electrical Wire Suitable for use in other Environmental Air Space
(Plenums) in accordance with section 300.22,(C) of the National Electrical Code, and Sections 2-128, 12-010(3) and 12-100 of teh Cnadian Electrical Code, Part 1 CSA C22.1 Peut tre utilis dans de gaines transportant de lair trait, conformment la section 300.22,(C) du National Electrical Eode et aux articles 2-128, 12-010(3) ET 12-100 du Code Candian de llectricit Premire partie, CSA C22.1. Plenum rated cables need to be used when the SWG is installed in a plenum. SWG needs to connected to PoE networks without routing to outside plant connections. T-Bar Clip Screw T-Bar Clip Arms Back of the SWG Unit STEP 3:
Attach to T-Bar ceiling by spreading the clip arms apart to appropriate width and snap the clip onto the T-Bar. See Figure 2. INSTALLATION STEP 1:
Insert electrical wire into the back of the SWG unit. See Figure 1. NOTE: Plenum rated cables need to be used when the SWG is installed in a plenum. STEP 2:
Insert the T-Bar clip into the back of the SWG unit using provided screw as shown in Figure 2. 1 of 2 INSTALLATION INSTRUCTIONSCSC-GW-CWC SmartCast Wireless GatewayIncludes: T-Bar MountingLPN00584X0001A0_A CONNECTING TO YOUR SMARTCAST NETWORK FCC NOTICE STEP 1:
Using a Cat 5 or Cat 6 cable, connect the SmartCast Wireless Gateway to a 802.3af compatible PoE switch via the ethernet connector (RJ45) found on the backside of the device. STEP 2:
After connecting your device to a PoE switch, the AMBER and GREEN LEDs located on the connector will illuminate, indicating the device is powered on and successfully communicating to the PoE switch. NOTE: If a PoE DC injector is used, the LEDs may not illuminate until the network has been established. Please refer to the SmartCast Link Configuration Guide for further information on how to configure your device in your SmartCast network. TROUBLESHOOTING:
If LEDs do not illuminate:
1. Check that the network cable is connected to a 802.3af compatible PoE switch and the power to the PoE switch is turned on. 2. Check that the network cable is fully seated in the connector on the back side of the SmartCast Wireless Gateway such that the locking feature is fully engaged. 3. Please refer to the SmartCast Link Configuration Guide for further troubleshooting information. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the device. This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the device is operated in a commercial environment. This device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. In addition, this device complies with ICES-005 of the Industry Canada
(IC) Regulations. INDUSTRY CANADA STATEMENT This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. In addition, this device complies with ICES-005 of the Industry Canada (IC) Regulations. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 2 of 2 LPN00584X0001A0_Awww.cree.com/lighting 2018 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See http://ligthing.cree.com/warranty for warranty and specifications. Cree and SmartCast are registered trademarks, and the Cree logo is a trademark of Cree, Inc.