IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Before installing wall controls turn off the power at the circuit breaker. Couper lalimentation avant linstallation 2. These wall controls must be installed in accordance with the national and local building codes and electrical wiring codes including wiring methods and wiring connections. If you are not electrician. Ce produit doit tre install conformment NEC ou votre code lectrique local. Si vous ntes pas familier avec ces codes et ces Indoor use only and suitable for damp locations. Pour usage interieur seulement et convient aux emplacements humides. 3. 4. equipment. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE TOP 5NW1 CSC-CCD 2 TOP 5NW1 CSC-CWS 1 On Off 3 Cree Wireless Wall Controls With SmartCast Technology Wireless Dimmer and Wireless Switch Includes:CSC-CWD, CSC-CWS, CSC-CCD INSTALLATION INSTRUCTIONS INSTRUCTIONS DINSTALLATION TOP 5NW1 CSC-CCD WIRELESS DIMMER CSC-CWD, CSC-CCD 120-277VAC 60Hz XX APPLIANCE CONTROLS 18AWG Cu wire Made in China WIRELESS SWITCH CWS-CWC TOP 5NW1 CSC-CWS 120-277VAC 60Hz XX APPLIANCE CONTROLS 18AWG Cu wire Made in China NEUT GND LINE Dimming Up LED Dimming Down On Off 4 LINE 120-277VAC 60Hz XX APPLIANCE CONTROLS 18AWG Cu wire Made in China 120-277VAC 60Hz XX APPLIANCE CONTROLS 18AWG Cu wire Made in China LED GND LINE IN LINE TO LOAD SUPPLY LEADS SUPPLY LEADS WALL CONTROLS FEATURES INSTALLATION The Cree Wireless Dimmer supports on, off, and dimming controls. See Figure 1. NOTE: For ease of installation, Cree recommends using a deep wall box. The Cree Wireless CCT Dimmer supports on, off, and dimming, and color controls. Color is adjusted up by simultaneously pressing the On and Dimming up buttons. Color is adjusted down by simultaneously pressing the Off and Dimming down buttons. See Figure 1. The Cree Wireless Switch supports on and off, controls. See Figure 2. STEP 1:
Disconnect power to circuit by turning circuit breaker OFF before installation. STEP 2:
If necessary remove existing wall plate and switch. STEP 3:
Strip existing wires ". If two wires will be connected to the same terminal on the Cree device, both wires must be the same gauge
(12AWG or 14AWG). STEP 4:
Wire the LINE (black), NEUTRAL (white), and GND (green or bare) supply wires to the corresponding pigtail leads on the Cree device, as shown in Figure 3. For wireless dimmers with no neutral wire. Wire the LINE IN (black) to supply wires, LINE OUT to the switched power, and GND (green or bare) supply wires to the corresponding pigtails on the Cree device, as shown in Figure 4. NOTE: If replacing an existing wall switch with a wireless dimmer with neutral wire connection, the wall dimmer shall be wired as instructed; however, the switched power to the load must also be tied directly to the AC supply leads. STEP 5:
Attach the wall plate (reference the wall plate instruction sheet). STEP 6:
Switch the circuit breaker ON. STEP 7:
Press and release the OFF paddle. The blue LED should blink twice and then go off. If the blue LED does not respond with the two-blink sequence, please follow the RESET instructions to return the wall control to factory defaults. LPN00838X0001A0_A Voltage: 120-277V, 60Hz Depth in Wall: 1.5"
Type 1 enclosure & IP20 Indoor use Operating Temperature limit of the control: 0 to 35C For ease of installation, Cree recommends the use of a deep wall Software Class A Lighting Controls NOT FOR USE WITH METALLIC FACEPLATES. Pollution degree 2 Suitable for normal household air circulation The Cree Wireless Wall Controls are used with other SmartCast Technology enabled devices to provide wireless control of LED luminaires. The Cree Wireless Wall Controls provide on, off, dimming control, and color adjustment. UNIT DESCRIPTION LOAD TYPES Cree Wall Controls support Cree SmartCast Technology enabled devices only. 1 of 3 LPN00838X0001A0_A 2 of 3 RESET WALL CONTROLS STEP 1:
Press/Hold (approx 30 sec) ON paddle until the LED flashes fast. STEP 2:
Briefly release the paddle for less than 1 sec (Fast flashing continues) STEP 3:
Press/Hold ON paddle for 1 sec until fast flashing stops. If the blue LED does not respond with the two-blink sequence, please repeat the RESET procedure. CLEANING Clean using a cloth dampened only with water and a little mild detergent. Use of solvents or hydrocarbon-based cleaners may cause permanent damage. Wall Control Troubleshooting Issue Resolution Check wiring
(LINE/NEUT/GND required) Wall Control LED does not blink in a 2-blink sequence prior to OneButton Setup Check connected load for wireless dimmers without neutral. Minimum load must be wired to dimmer (minimum load indicated on spec sheet). Wall Control will not join a network Reset Device and verify 2-blink sequence for the LED Check wiring (NEUT required) NOTE: LED may illuminate if NEUT not connected Check connected load for wireless dimmers without neutral. Minimum load must be wired to dimmer (minimum load indicated on spec sheet). Reset Device and verify 2-blink sequence for the LED Replaced existing Wall Control and fixtures will not turn on Check Wiring (each fixture shall be wired with constant HOT) Wall Control will not control fixtures Check group assignments with Configuration Tool This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the device. This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the device is operated in a commercial environment. This device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. In addition, this device complies with ICES-003 of the Industry Canada (IC) Regulations. FCC NOTICE INDUSTRY CANADA STATEMENT This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. In addition, this device complies with ICES-003 of the Industry Canada (IC) Regulations. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 2020 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content is subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree and the Cree logo are registered trademarks and the Cree SmartCast Technology logo is a trademark of Cree, Inc. SmartCast, is a registered trademark of Cree Lighting, A company of IDEAL INDUSTRIES. 3 of 3 www.creelighting.com LPN00838X0001A0_A MEDIDAS DE SEGURIDAD IMPORTANTES Al usar aparatos elctricos, siempre deben seguirse ciertas medidas bsicas de seguridad, incluidas las siguientes:
LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD 1. Antes de instalar los controles de pared, desconecte la alimentacin elctrica en el disyuntor. Couper lalimentation avant linstallation. 2. Estos controles de pared deben instalarse de acuerdo con los cdigos de construccin nacionales y locales, y los cdigos de cableado elctrico, incluidos los mtodos de cableado y las conexiones de cableado. Si no est familiarizado con estos cdigos y Ce produit doit tre install conformment NEC ou votre code lectrique local. Si vous ntes pas familier avec ces codes et ces 3. Este producto es solo para uso en interiores y es adecuado para uso en lugares hmedos. Pour usage interieur seulement et convient aux emplacements humides. 4. explcitamente aprobado por el fabricante podra anular su autoridad para operar este equipo. CONSERVE ESTAS INSTRUCCIONES PARA CONSULTAS POSTERIORES Controles de pared inalmbricos Cree con tecnologa SmartCast Atenuador inalmbrico e interruptor inalmbrico Incluye: CSC-CWD, CSC-CWS, CSC-CCD INSTRUCCIONES DE INSTALACIN INSTRUCTIONS DINSTALLATION TOP 5NW1 CSC-CCD 1 Encendido Apagado ATENUADOR INALMBRICO CSC-CWD, CSC-CCD 120-277VAC 60Hz XX APPLIANCE CONTROLS 18AWG Cu wire Made in China TOP 5NW1 CSC-CWS 120-277VAC 60Hz XX APPLIANCE CONTROLS 18AWG Cu wire Made in China INTERRUPTOR INALMBRICO CWS-CWC 3 NEUTRO TOP 5NW1 CSC-CCD 2 TOP 5NW1 CSC-CWS 120-277VAC 60Hz XX APPLIANCE CONTROLS 18AWG Cu wire Made in China 120-277VAC 60Hz XX APPLIANCE CONTROLS 18AWG Cu wire Made in China Incrementar atenuacin LED Reducir atenuacin TIERRA LNEA CABLES DE ALIMENTACIN Encendido Apagado 4 LNEA LED TIERRA ENTRADA DE LNEA LNEA A CARGA CABLES DE ALIMENTACIN Voltaje: 120-277 V, 60 Hz Cerramiento tipo 1 y uso en interiores IP20 Profundidad en la pared: 1.5" (8.63 cm) Lmite de temperatura de funcionamiento del control: De 0 a 35 C Para facilitar la instalacin, Cree recomienda el uso de una caja de Controles de iluminacin de clase A de software pared profunda Grado de contaminacin 2 adecuado para la circulacin normal del NO SE DEBE USAR CON PLACAS FRONTALES METLICAS aire en el hogar Voltaje de impulso nominal: 4000 V FUNCIONES DE LOS CONTROLES DE PARED INSTALACIN DESCRIPCIN DE LA UNIDAD Los controles de pared inalmbricos Cree se usan con otros dispositivos habilitados con tecnologa SmartCast para proporcionar control inalmbrico de luminarias LED. Los controles de pared inalmbricos Cree proporcionan control de encendido, apagado y atenuacin, y ajuste de color. TIPOS DE CARGA Los controles de pared Cree solo son compatibles con dispositivos con tecnologa Cree SmartCast. 1 de 3 LPN00838X0001A0_A 2 de 3 El atenuador inalmbrico Cree es compatible con controles de encendido, apagado y atenuacin. Consulte la Figura 1. El atenuador CCT inalmbrico Cree es compatible con controles de encendido, apagado, atenuacin y colores. El color se sube presionando en simultneo los botones para encender y para incrementar la atenuacin. El color se baja presionando en simultneo los botones para apagar y reducir la atenuacin. Consulte la Figura 1. El interruptor inalmbrico Cree es compatible con los controles de encendido y apagado. Consulte la Figura 2. NOTA: Para facilitar la instalacin, Cree recomienda el uso de una caja de pared profunda. a los espirales correspondientes del dispositivo Cree, como se muestra en la Figura 4. PASO 1:
Desconecte la energa del circuito apagando el disyuntor antes de la instalacin. PASO 2:
Si es necesario, retire la placa de pared y el interruptor existentes. PASO 3:
Pele los cables existentes de ". Si se van a conectar dos cables al mismo terminal en el dispositivo Cree, ambos cables deben ser del PASO 4:
Conecte los cables de suministro de LNEA (negro), NEUTRO (blanco) y TIERRA (verde o desnudo) a los cables espirales correspondientes del dispositivo Cree, como se muestra en la Figura 3. Para atenuadores inalmbricos sin cable neutro. Conecte la ENTRADA DE LNEA (negro) a los cables de suministro, la SALIDA DE LNEA al suministro de energa y TIERRA (verde o desnudo) NOTA: Si se reemplaza un interruptor de pared existente con un atenuador inalmbrico con conexin de cable neutro, el atenuador de pared se debe conectar segn las instrucciones; sin embargo, el suministro de energa a la carga tambin debe conectarse directamente a los cables de alimentacin de CA. PASO 5:
Acople la placa de pared (consulte la hoja de instrucciones de la placa de pared). PASO 6:
Encienda el disyuntor. PASO 7:
Presione y libere la paleta de apagado. El LED azul parpadear dos veces y luego se apagar. Si el LED azul no responde con la secuencia de dos parpadeos, siga las instrucciones en RESTABLECER para que el control de pared vuelva a tener los valores de fbrica. LPN00838X0001A0_A RESTABLECER LOS CONTROLES DE PARED PASO 1:
Mantenga presionado (durante aproximadamente parpadee rpidamente. PASO 2:
Suelte brevemente la paleta durante menos de 1 segundo (el parpadeo rpido contina). PASO 3:
Mantenga presionada la paleta de encendido durante LED azul no responde con la secuencia de dos parpadeos, repita el procedimiento de RESTABLECER. LIMPIEZA Limpie con un trapo empapado con solamente agua y un poco de detergente suave. El uso de disolventes o limpiadores a base de hidrocarburos puede ocasionar daos permanentes. Solucin de problemas del control de pared:
Problema Solucin El LED del control de pared no parpadea en una secuencia de dos parpadeos antes de configurar OneButton. El control de pared no se conecta a la red. Verifique el cableado
(se requiere LNEA/NEUTRO/TIERRA). Verifique la carga conectada para los atenuadores inalmbricos sin el neutro. atenuador (la carga mnima se indica en la hoja de especificaciones). Restablezca el dispositivo y verifique la secuencia de dos parpadeos del LED. Verifique el cableado (se requiere NEUTRO). NOTA: Es posible que el LED se ilumine si no se conecta el NEUTRO. Verifique la carga conectada para los atenuadores inalmbricos sin el neutro. atenuador (la carga mnima se indica en la hoja de especificaciones). Restablezca el dispositivo y verifique la secuencia de dos parpadeos del LED. El control de pared y las luminarias reemplazadas existentes no se encienden. Verifique el cableado (cada luminaria se debe conectar a VIVO constante). El control de pared no controla las luminarias. Verifique las asignaciones de grupo con la herramienta de configuracin. Este dispositivo cumple con el apartado 15 de las normas de la dispositivo no debe causar interferencias dainas y (2) este dispositivo debe aceptar cualquier interferencia recibida, incluyendo aquellas que puedan causar un uso indeseado. Cualquier cambio o modificacin no aprobado expresamente por la parte responsable del cumplimiento podra anular la autoridad del usuario para usar el dispositivo. Este dispositivo ha sido sometido a pruebas y cumple con los lmites de un dispositivo digital Clase A, de acuerdo con el apartado 15 de las normas de la FCC. Estos lmites se disearon a fin de brindar una proteccin razonable contra interferencias perjudiciales en instalaciones comerciales. Este dispositivo genera, usa y puede irradiar energa de radiofrecuencia y, si no se instala y usa de acuerdo con el manual de instrucciones, puede causar interferencias dainas a las comunicaciones de radio. Es probable que el uso de este dispositivo en un rea residencial cause interferencias perjudiciales, en cuyo caso el usuario deber corregir dicha interferencia por su propia cuenta. Adems, este dispositivo cumple con las normas ICES-003 de Industry Canada (IC). AVISO DE LA FCC DECLARACIN DE INDUSTRY CANADA Este dispositivo cumple con los estndares RSS exentos de licencia de Industry Canada. El uso est sujeto a las dos condiciones siguientes:
(1) Este dispositivo no debe causar interferencias y (2) este dispositivo debe aceptar cualquier interferencia, incluyendo aquellas que puedan causar un uso indeseado del dispositivo. Adems, este dispositivo cumple con las normas ICES-003 de Industry Canada (IC). Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes: (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 2020 Cree Lighting, una empresa de IDEAL INDUSTRIES. Todos los derechos reservados. Para fines informativos nicamente. El contenido est sujeto a cambios. Visite www.creelighting.com/warranty para ver la garanta y las especificaciones. Cree y el logotipo Cree son marcas comerciales registradas y el logotipo Cree SmartCast Technology es una marca registrada de Cree, Inc. SmartCast es una marca comercial registrada de Cree Lighting, una compaa de IDEAL INDUSTRIES. 3 de 3 www.creelighting.com LPN00838X0001A0_A